Nagy G, Földesi R, Csípő I, Tarr T, Szűcs G, Szántó A, Bubán T, Szekanecz Z, Papp M, Kappelmayer J, Antal-Szalmás P. A novel way to evaluate autoantibody interference in samples with mixed antinuclear antibody patterns in the HEp-2 cell based indirect immunofluorescence assay and comparison of conventional microscopic and computer-aided pattern recognition. Clin Chim Acta 2024; 553:117747. [PMID: 38154766 DOI: 10.1016/j.cca.2023.117747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/22/2023] [Accepted: 12/25/2023] [Indexed: 12/30/2023]
Abstract
BACKGROUND A major challenge of the HEp-2 cell-based indirect immunofluorescence (IIF) assays is the correct identification of the individual anti-nuclear antibodies (ANAs) if more than one is present in a sample. We created artificial mixes by pooling two different samples with a single autoantibody in different titers. Comparison of the expected and observed patterns and titers clarifies the interference between the two tested ANAs. METHODS Serum samples with a single homogeneous or speckled ANA pattern were serially diluted and mixed in 16 combinations, providing end-point titers of 1:5,120 to 1:80 for both patterns. These mixes were tested by a HEp-2 IIF assay and were evaluated by conventional evaluation, the EUROPattern (EPa) system and on-screen analysis. RESULTS Homogeneous pattern can alter the identification of the speckled pattern much more than vice versa, but both has an interfering effect on the other. The effect of the interfering on the tested pattern was higher if the titer of the former one was higher. The pattern recognition efficacy of conventional and the on-screen evaluation was similar and superior compared to the EPa analysis. CONCLUSIONS The application of artificial mixed samples can help the evaluation of the efficacy of manual and computer-aided ANA HEp-2 pattern recognition.
Collapse
Affiliation(s)
- Gábor Nagy
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Róza Földesi
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - István Csípő
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Tünde Tarr
- Institute of Internal Medicine, Department of Clinical Immunology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Gabriella Szűcs
- Institute of Internal Medicine, Department of Rheumatology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Antónia Szántó
- Institute of Internal Medicine, Department of Clinical Immunology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Tamás Bubán
- Department of Gastroenterology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Zoltán Szekanecz
- Institute of Internal Medicine, Department of Rheumatology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Mária Papp
- Department of Gastroenterology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary; European Reference Network on Hepatological Diseases, ERN RARE-LIVER, Debrecen, Hungary
| | - János Kappelmayer
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Péter Antal-Szalmás
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
| |
Collapse
|
2
|
Ray ME, Rothstein TL. Human VH4-34 antibodies derived from B1 cells are more frequently autoreactive than VH4-34 antibodies derived from memory cells. Front Immunol 2023; 14:1259827. [PMID: 38162664 PMCID: PMC10754998 DOI: 10.3389/fimmu.2023.1259827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 11/20/2023] [Indexed: 01/03/2024] Open
Abstract
Human B1 cells produce natural antibodies characterized by overutilization of heavy chain variable region VH4-34 in comparison to other B cell populations. VH4-34-containing antibodies have been reported to be autoreactive and to be associated with lupus and other autoimmune dyscrasias. However, it has been unclear to what extent VH4-34 antibodies manifest autoreactivity in B1 cells or other B cell populations-in other words, are VH4-34 containing antibodies autoreactive wherever found, or mainly within the B1 cell population? To address this issue we sort purified single human B1 and memory B cells and then amplified, sequenced, cloned and expressed VH4-34-containing antibodies from 76 individual B cells. Each of these antibodies was tested for autoreactivity by HEp-2 IFA and autoantigen ELISA. Antibodies were scored as autoreactive if positive by either assay. We found VH4-34 antibodies rescued from B1 cells were much more frequently autoreactive (14/48) than VH4-34 antibodies rescued from memory B cells (2/28). Among B1 cell antibodies, 4 were HEp-2+, 6 were dsDNA+ and 4 were positive for both. Considering only HEp-2+ antibodies, again these were found more frequently among B1 cell VH4-34 antibodies (8/48) than memory B cell VH4-34 antibodies (1/28). We found autoreactivity was associated with greater CDR3 length, as expected; however, we found no association between autoreactivity and a previously described FR1 "hydrophobic patch". Our results indicate that autoreactive VH4-34-containing antibodies tend to reside within the human B1 cell population.
Collapse
Affiliation(s)
| | - Thomas L. Rothstein
- Center for Immunobiology and Department of Investigative Medicine, Western Michigan University Homer Stryker M.D. School of Medicine, Kalamazoo, MI, United States
| |
Collapse
|
3
|
Chung HJ, Hur M, Choi SG, Lee HK, Lee S, Kim H, Moon HW, Yun YM. Benefits of VISION Max automated cross-matching in comparison with manual cross-matching: A multidimensional analysis. PLoS One 2019; 14:e0226477. [PMID: 31869405 PMCID: PMC6927601 DOI: 10.1371/journal.pone.0226477] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 11/26/2019] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND VISION Max (Ortho-Clinical Diagnostics, Raritan, NJ, USA) is a newly introduced automated blood bank system. Cross-matching (XM) is an important test confirming safety by simulating reaction between packed Red Blood Cells (RBCs) and patient blood in vitro before transfusion. We assessed the benefits of VISION Max automated XM (A-XM) in comparison with those of manual XM (M-XM) by using multidimensional analysis (cost-effectiveness and quality improvement). MATERIALS AND METHODS In a total of 327 tests (130 patients), results from A-XM and M-XM were compared. We assessed the concordance rate, risk priority number (RPN), turnaround time, hands-on time, and the costs of both methods. We further simulated their annual effects based on 37,937 XM tests in 2018. RESULTS The concordance rate between A-XM and M-XM was 97.9% (320/327, kappa = 0.83), and the seven discordant results were incompatible for transfusion in A-XM, while compatible for transfusion in M-XM. None of the results was incompatible for transfusion in A-XM, while compatible for transfusion in M-XM, meaning A-XM detect agglutination more sensitively and consequently provides a more safe result than M-XM. A-XM was estimated to have a 6.3-fold lower risk (229 vs. 1,435 RPN), shorter turnaround time (19.1 vs. 23.3 min, P < 0.0001), shorter hands-on time (1.1 vs. 5.3 min, P < 0.0001), and lower costs per single test than M-XM (1.44 vs. 2.70 USD). A-XM permitted annual savings of 46 million RPN, 15.1 months of daytime workers' labor, and 47,042 USD compared with M-XM. CONCLUSION This is the first attempt to implement A-XM using VISION Max. VISION Max A-XM appears to be a safe, practical, and reliable alternative for pre-transfusion workflow with the potential to improve quality and cost-effectiveness in the blood bank.
Collapse
Affiliation(s)
- Hee-Jung Chung
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| | - Mina Hur
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| | - Sang Gyeu Choi
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| | - Hyun-Kyung Lee
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| | - Seungho Lee
- Department of Occupational and Environmental Medicine, Ajou University Medicine, Suwon, South Korea
| | - Hanah Kim
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| | - Hee-Won Moon
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| | - Yeo-Min Yun
- Department of Laboratory Medicine, Konkuk University Medical Center and Konkuk University School of Medicine, Seoul, South Korea
| |
Collapse
|
4
|
Wu S, Wang F, Huang J, Yin B, Huang M, Wei W, Zhang M, Ouyang R. Evaluation of the automated indirect immunofluorescence test for anti-dsDNA antibodies. Clin Chim Acta 2019; 498:143-147. [PMID: 31442448 DOI: 10.1016/j.cca.2019.08.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 08/19/2019] [Accepted: 08/19/2019] [Indexed: 11/26/2022]
Abstract
BACKGROUND Anti-dsDNA antibody is a specific antibody in systemic lupus erythematosus (SLE). Indirect immunofluorescence test (IIFT) is a highly specific method in detecting anti-dsDNA antibody. The application of automated system has gained better consistency than manual operation. This study detected anti-dsDNA antibodies using EUROPattern Computer-aided immunofluorescence microscopy (EPA), and evaluated the performance of the automated system. METHODS The sera of 96 patients with suspected SLE and 102 control patients were examined using IIFT. The consistency between the EPA and manual reading was analyzed. RESULTS Analysis of 198 samples showed that the overall consistency of the negative/positive results between the EPA and manual reading was 94.95%. Based on the manual reading results, the sensitivity and specificity of EPA were 95.70% and 94.29%, respectively. The analysis of 57 samples with non-specific fluorescence showed that the overall consistency of the negative/positive results was 96.49%. The analysis of the antibody titer of 89 positive samples showed that the consistency between the EPA and manual reading was 97.75%. CONCLUSION EPA was consistent with the manual reading with regard to qualitative reading and antibody titer. With low-exposure function, EPA could read samples with non-specific fluorescence. EPA was superior to manual reading in automation and standardization.
Collapse
Affiliation(s)
- Shiji Wu
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
| | - Feng Wang
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Jin Huang
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Botao Yin
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Min Huang
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Wei Wei
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Minxia Zhang
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Renren Ouyang
- Department of Clinical Laboratory, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| |
Collapse
|
5
|
Li Z, Han R, Yan Z, Li L, Feng Z. Antinuclear antibodies detection: A comparative study between automated recognition and conventional visual interpretation. J Clin Lab Anal 2018; 33:e22619. [PMID: 30030865 DOI: 10.1002/jcla.22619] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Accepted: 06/20/2018] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND The indirect immunofluorescence assay (IIFA) for the detection of antinuclear antibodies (ANA) was firstly described in 1958 and is still considered the reference method for ANA screening. Currently, an automated processing and recognition system for standardized and efficient ANA interpretation by human epithelial (HEp-2) cell-based immunofluorescence (IIF; EUROPattern Suite, Euroimmun) is available in China. METHODS In this study, the performance of this novel system for positive/negative classification, pattern recognition (including homogenous, speckled, nucleolar, nuclear dots, cytoplasmic, and centromeres patterns) and titers evaluation was evaluated by comparing to visual interpretation. RESULTS Referring to the total of 3681 collected samples, there was an agreement of 98.7% (κ = 0.973) between the visual and automated examination regarding positive/negative discrimination. In sera with single pattern, correct pattern recognition was observed in 94.6% of the samples. The efficiency of automated recognition for single pattern varied for the different patterns. The automatically determined patterns were correct and complete in 1071 of 1620 cases and correct and meaningful but not complete ("main pattern") in another 405 cases, enabling main pattern recognition in 91.1% of all cases. Referring to the titers evaluation, the results within the next titer were considered to be consistent. In 1603 positive sera both by visual and automated evaluation, titers of 1514 sample were consistent, accounting for 94.4%. CONCLUSION Attributed to the performance characteristics, EUROPattern system is suitable for clinical use as its high degree of automation and result reliability, and may help clinical laboratories to standardize of IIF evaluation.
Collapse
Affiliation(s)
- ZhiYan Li
- Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
| | - RuiLin Han
- Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
| | - ZhenLin Yan
- Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
| | - LiJuan Li
- Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
| | - ZhenRu Feng
- Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
| |
Collapse
|