1
|
Evaluation of deep learning reconstruction on diffusion-weighted imaging quality and apparent diffusion coefficient using an ice-water phantom. Radiol Phys Technol 2024; 17:186-194. [PMID: 38153622 DOI: 10.1007/s12194-023-00765-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/29/2023]
Abstract
This study assessed the influence of deep learning reconstruction (DLR) on the quality of diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) using an ice-water phantom. An ice-water phantom with known diffusion properties (true ADC = 1.1 × 10-3 mm2/s at 0 °C) was imaged at various b-values (0, 1000, 2000, and 4000 s/mm2) using a 3 T magnetic resonance imaging scanner with slice thicknesses of 1.5 and 3.0 mm. All DWIs were reconstructed with or without DLR. ADC maps were generated using combinations of b-values 0 and 1000, 0 and 2000, and 0 and 4000 s/mm2. Based on the quantitative imaging biomarker alliance profile, the signal-to-noise ratio (SNRs) in DWIs was calculated, and the accuracy, precision, and within-subject parameter variance (wCV) of the ADCs were evaluated. DLR improved the SNR in DWIs with b-values ranging from 0 to 2000s/mm2; however, its effectiveness was diminished at 4000 s/mm2. There was no noticeable difference in the ADCs of images generated with or without implementing DLR. For a slice thickness of 1.5 mm and combined b-values of 0 and 4000 s/mm2, the ADC values were 0.97 × 10-3and 0.98 × 10-3mm2/s with and without DLR, respectively, both being lower than the true ADC value. Furthermore, DLR enhanced the precision and wCV of the ADC measurements. DLR can enhance the SNR, repeatability, and precision of ADC measurements; however, it does not improve their accuracies.
Collapse
|
2
|
Repeatability and reproducibility of apparent exchange rate measurements in yeast cell phantoms using filter-exchange imaging. MAGMA (NEW YORK, N.Y.) 2023; 36:957-974. [PMID: 37436611 PMCID: PMC10667135 DOI: 10.1007/s10334-023-01107-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 06/21/2023] [Accepted: 06/22/2023] [Indexed: 07/13/2023]
Abstract
OBJECTIVES Development of a protocol for validation and quality assurance of filter-exchange imaging (FEXI) pulse sequences with well-defined and reproducible phantoms. MATERIALS AND METHODS A FEXI pulse sequence was implemented on a 7 T preclinical MRI scanner. Six experiments in three different test categories were established for sequence validation, demonstration of the reproducibility of phantoms and the measurement of induced changes in the apparent exchange rate (AXR). First, an ice-water phantom was used to investigate the consistency of apparent diffusion coefficient (ADC) measurements with different diffusion filters. Second, yeast cell phantoms were utilized to validate the determination of the AXR in terms of repeatability (same phantom and session), reproducibility (separate but comparable phantoms in different sessions) and directionality of diffusion encodings. Third, the yeast cell phantoms were, furthermore, used to assess potential AXR bias because of altered cell density and temperature. In addition, a treatment experiment with aquaporin inhibitors was performed to evaluate the influence of these compounds on the cell membrane permeability in yeast cells. RESULTS FEXI-based ADC measurements of an ice-water phantom were performed for three different filter strengths, showed good agreement with the literature value of 1.099 × 10-3 mm2/s and had a maximum coefficient of variation (CV) of 0.55% within the individual filter strengths. AXR estimation in a single yeast cell phantom and imaging session with five repetitions resulted in an overall mean value of (1.49 ± 0.05) s-1 and a CV of 3.4% between the chosen regions of interest. For three separately prepared phantoms, AXR measurements resulted in a mean value of (1.50 ± 0.04) s-1 and a CV of 2.7% across the three phantoms, demonstrating high reproducibility. Across three orthogonal diffusion directions, a mean value of (1.57 ± 0.03) s-1 with a CV of 1.9% was detected, consistent with isotropy of AXR in yeast cells. Temperature and AXR were linearly correlated (R2 = 0.99) and an activation energy EA of 37.7 kJ/mol was determined by Arrhenius plot. Furthermore, a negative correlation was found between cell density (as determined by the reference ADC/fe) and AXR (R2 = 0.95). The treatment experiment resulted in significantly decreased AXR values at different temperatures in the treated sample compared to the untreated control indicating an inhibiting effect. CONCLUSIONS Using ice-water and yeast cell-based phantoms, a protocol for the validation of FEXI pulse sequences was established for the assessment of stability, repeatability, reproducibility and directionality. In addition, a strong dependence of AXR on cell density and temperature was shown. As AXR is an emerging novel imaging biomarker, the suggested protocol will be useful for quality assurance of AXR measurements within a study and potentially across multiple sites.
Collapse
|
3
|
Evaluation of Apparent Diffusion Coefficient Repeatability and Reproducibility for Preclinical MRIs Using Standardized Procedures and a Diffusion-Weighted Imaging Phantom. Tomography 2023; 9:375-386. [PMID: 36828382 PMCID: PMC9964373 DOI: 10.3390/tomography9010030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/31/2023] [Accepted: 02/02/2023] [Indexed: 02/10/2023] Open
Abstract
Relevant to co-clinical trials, the goal of this work was to assess repeatability, reproducibility, and bias of the apparent diffusion coefficient (ADC) for preclinical MRIs using standardized procedures for comparison to performance of clinical MRIs. A temperature-controlled phantom provided an absolute reference standard to measure spatial uniformity of these performance metrics. Seven institutions participated in the study, wherein diffusion-weighted imaging (DWI) data were acquired over multiple days on 10 preclinical scanners, from 3 vendors, at 6 field strengths. Centralized versus site-based analysis was compared to illustrate incremental variance due to processing workflow. At magnet isocenter, short-term (intra-exam) and long-term (multiday) repeatability were excellent at within-system coefficient of variance, wCV [±CI] = 0.73% [0.54%, 1.12%] and 1.26% [0.94%, 1.89%], respectively. The cross-system reproducibility coefficient, RDC [±CI] = 0.188 [0.129, 0.343] µm2/ms, corresponded to 17% [12%, 31%] relative to the reference standard. Absolute bias at isocenter was low (within 4%) for 8 of 10 systems, whereas two high-bias (>10%) scanners were primary contributors to the relatively high RDC. Significant additional variance (>2%) due to site-specific analysis was observed for 2 of 10 systems. Base-level technical bias, repeatability, reproducibility, and spatial uniformity patterns were consistent with human MRIs (scaled for bore size). Well-calibrated preclinical MRI systems are capable of highly repeatable and reproducible ADC measurements.
Collapse
|
4
|
Repeatability and reproducibility of ADC measurements: a prospective multicenter whole-body-MRI study. Eur Radiol 2021; 31:4514-4527. [PMID: 33409773 DOI: 10.1007/s00330-020-07522-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/31/2020] [Accepted: 11/13/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVES Multicenter oncology trials increasingly include MRI examinations with apparent diffusion coefficient (ADC) quantification for lesion characterization and follow-up. However, the repeatability and reproducibility (R&R) limits above which a true change in ADC can be considered relevant are poorly defined. This study assessed these limits in a standardized whole-body (WB)-MRI protocol. METHODS A prospective, multicenter study was performed at three centers equipped with the same 3.0-T scanners to test a WB-MRI protocol including diffusion-weighted imaging (DWI). Eight healthy volunteers per center were enrolled to undergo test and retest examinations in the same center and a third examination in another center. ADC variability was assessed in multiple organs by two readers using two-way mixed ANOVA, Bland-Altman plots, coefficient of variation (CoV), and the upper limit of the 95% CI on repeatability (RC) and reproducibility (RDC) coefficients. RESULTS CoV of ADC was not influenced by other factors (center, reader) than the organ. Based on the upper limit of the 95% CI on RC and RDC (from both readers), a change in ADC in an individual patient must be superior to 12% (cerebrum white matter), 16% (paraspinal muscle), 22% (renal cortex), 26% (central and peripheral zones of the prostate), 29% (renal medulla), 35% (liver), 45% (spleen), 50% (posterior iliac crest), 66% (L5 vertebra), 68% (femur), and 94% (acetabulum) to be significant. CONCLUSIONS This study proposes R&R limits above which ADC changes can be considered as a reliable quantitative endpoint to assess disease or treatment-related changes in the tissue microstructure in the setting of multicenter WB-MRI trials. KEY POINTS • The present study showed the range of R&R of ADC in WB-MRI that may be achieved in a multicenter framework when a standardized protocol is deployed. • R&R was not influenced by the site of acquisition of DW images. • Clinically significant changes in ADC measured in a multicenter WB-MRI protocol performed with the same type of MRI scanner must be superior to 12% (cerebrum white matter), 16% (paraspinal muscle), 22% (renal cortex), 26% (central zone and peripheral zone of prostate), 29% (renal medulla), 35% (liver), 45% (spleen), 50% (posterior iliac crest), 66% (L5 vertebra), 68% (femur), and 94% (acetabulum) to be detected with a 95% confidence level.
Collapse
|
5
|
Repeatability and reproducibility of longitudinal relaxation rate in 12 small-animal MRI systems. Magn Reson Imaging 2019; 59:121-129. [PMID: 30872166 PMCID: PMC6477178 DOI: 10.1016/j.mri.2019.03.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 01/29/2019] [Accepted: 03/08/2019] [Indexed: 12/13/2022]
Abstract
BACKGROUND Many translational MR biomarkers derive from measurements of the water proton longitudinal relaxation rate R1, but evidence for between-site reproducibility of R1 in small-animal MRI is lacking. OBJECTIVE To assess R1 repeatability and multi-site reproducibility in phantoms for preclinical MRI. METHODS R1 was measured by saturation recovery in 2% agarose phantoms with five nickel chloride concentrations in 12 magnets at 5 field strengths in 11 centres on two different occasions within 1-13 days. R1 was analysed in three different regions of interest, giving 360 measurements in total. Root-mean-square repeatability and reproducibility coefficients of variation (CoV) were calculated. Propagation of reproducibility errors into 21 translational MR measurements and biomarkers was estimated. Relaxivities were calculated. Dynamic signal stability was also measured. RESULTS CoV for day-to-day repeatability (N = 180 regions of interest) was 2.34% and for between-centre reproducibility (N = 9 centres) was 1.43%. Mostly, these do not propagate to biologically significant between-centre error, although a few R1-based MR biomarkers were found to be quite sensitive even to such small errors in R1, notably in myocardial fibrosis, in white matter, and in oxygen-enhanced MRI. The relaxivity of aqueous Ni2+ in 2% agarose varied between 0.66 s-1 mM-1 at 3 T and 0.94 s-1 mM-1 at 11.7T. INTERPRETATION While several factors affect the reproducibility of R1-based MR biomarkers measured preclinically, between-centre propagation of errors arising from intrinsic equipment irreproducibility should in most cases be small. However, in a few specific cases exceptional efforts might be required to ensure R1-reproducibility.
Collapse
|
6
|
Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs. J Magn Reson Imaging 2019; 49:e26-e39. [PMID: 30680836 PMCID: PMC6663309 DOI: 10.1002/jmri.26598] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 11/16/2018] [Accepted: 11/16/2018] [Indexed: 12/12/2022] Open
Abstract
LEVEL OF EVIDENCE 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2019.
Collapse
|
7
|
Simultaneous characterization of tumor cellularity and the Warburg effect with PET, MRI and hyperpolarized 13C-MRSI. Am J Cancer Res 2018; 8:4765-4780. [PMID: 30279736 PMCID: PMC6160766 DOI: 10.7150/thno.25162] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Accepted: 06/26/2018] [Indexed: 02/07/2023] Open
Abstract
Modern oncology aims at patient-specific therapy approaches, which triggered the development of biomedical imaging techniques to synergistically address tumor biology at the cellular and molecular level. PET/MR is a new hybrid modality that allows acquisition of high-resolution anatomic images and quantification of functional and metabolic information at the same time. Key steps of the Warburg effect-one of the hallmarks of tumors-can be measured non-invasively with this emerging technique. The aim of this study was to quantify and compare simultaneously imaged augmented glucose uptake and LDH activity in a subcutaneous breast cancer model in rats (MAT-B-III) and to study the effect of varying tumor cellularity on image-derived metabolic information. Methods: For this purpose, we established and validated a multimodal imaging workflow for a clinical PET/MR system including proton magnetic resonance (MR) imaging to acquire accurate morphologic information and diffusion-weighted imaging (DWI) to address tumor cellularity. Metabolic data were measured with dynamic [18F]FDG-PET and hyperpolarized (HP) 13C-pyruvate MR spectroscopic imaging (MRSI). We applied our workflow in a longitudinal study and analyzed the effect of growth dependent variations of cellular density on glycolytic parameters. Results: Tumors of similar cellularity with similar apparent diffusion coefficients (ADC) showed a significant positive correlation of FDG uptake and pyruvate-to-lactate exchange. Longitudinal DWI data indicated a decreasing tumor cellularity with tumor growth, while ADCs exhibited a significant inverse correlation with PET standard uptake values (SUV). Similar but not significant trends were observed with HP-13C-MRSI, but we found that partial volume effects and point spread function artifacts are major confounders for the quantification of 13C-data when the spatial resolution is limited and major blood vessels are close to the tumor. Nevertheless, analysis of longitudinal data with varying tumor cellularity further detected a positive correlation between quantitative PET and 13C-data. Conclusions: Our workflow allows the quantification of simultaneously acquired PET, MRSI and DWI data in rodents on a clinical PET/MR scanner. The correlations and findings suggest that a major portion of consumed glucose is metabolized by aerobic glycolysis in the investigated tumor model. Furthermore, we conclude that variations in cell density affect PET and 13C-data in a similar manner and correlations of longitudinal metabolic data appear to reflect both biochemical processes and tumor cellularity.
Collapse
|
8
|
A new method for the high-precision assessment of tumor changes in response to treatment. Bioinformatics 2018; 34:2625-2633. [PMID: 29547950 PMCID: PMC6061877 DOI: 10.1093/bioinformatics/bty115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 02/05/2018] [Accepted: 03/12/2018] [Indexed: 11/12/2022] Open
Abstract
Motivation Imaging demonstrates that preclinical and human tumors are heterogeneous, i.e. a single tumor can exhibit multiple regions that behave differently during both development and also in response to treatment. The large variations observed in control group, tumors can obscure detection of significant therapeutic effects due to the ambiguity in attributing causes of change. This can hinder development of effective therapies due to limitations in experimental design rather than due to therapeutic failure. An improved method to model biological variation and heterogeneity in imaging signals is described. Specifically, linear Poisson modeling (LPM) evaluates changes in apparent diffusion co-efficient between baseline and 72 h after radiotherapy, in two xenograft models of colorectal cancer. The statistical significance of measured changes is compared to those attainable using a conventional t-test analysis on basic apparent diffusion co-efficient distribution parameters. Results When LPMs were applied to treated tumors, the LPMs detected highly significant changes. The analyses were significant for all tumors, equating to a gain in power of 4-fold (i.e. equivalent to having a sample size 16 times larger), compared with the conventional approach. In contrast, highly significant changes are only detected at a cohort level using t-tests, restricting their potential use within personalized medicine and increasing the number of animals required during testing. Furthermore, LPM enabled the relative volumes of responding and non-responding tissue to be estimated for each xenograft model. Leave-one-out analysis of the treated xenografts provided quality control and identified potential outliers, raising confidence in LPM data at clinically relevant sample sizes. Availability and implementation TINA Vision open source software is available from www.tina-vision.net. Supplementary information Supplementary data are available at Bioinformatics online.
Collapse
|
9
|
A biomimetic tumor tissue phantom for validating diffusion-weighted MRI measurements. Magn Reson Med 2018; 80:147-158. [PMID: 29154442 PMCID: PMC5900984 DOI: 10.1002/mrm.27016] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 09/22/2017] [Accepted: 10/27/2017] [Indexed: 12/20/2022]
Abstract
PURPOSE To develop a biomimetic tumor tissue phantom which more closely reflects water diffusion in biological tissue than previously used phantoms, and to evaluate the stability of the phantom and its potential as a tool for validating diffusion-weighted (DW) MRI measurements. METHODS Coaxial-electrospraying was used to generate micron-sized hollow polymer spheres, which mimic cells. The bulk structure was immersed in water, providing a DW-MRI phantom whose apparent diffusion coefficient (ADC) and microstructural properties were evaluated over a period of 10 months. Independent characterization of the phantom's microstructure was performed using scanning electron microscopy (SEM). The repeatability of the construction process was investigated by generating a second phantom, which underwent high resolution synchrotron-CT as well as SEM and MR scans. RESULTS ADC values were stable (coefficients of variation (CoVs) < 5%), and varied with diffusion time, with average values of 1.44 ± 0.03 µm2 /ms (Δ = 12 ms) and 1.20 ± 0.05 µm2 /ms (Δ = 45 ms). Microstructural parameters showed greater variability (CoVs up to 13%), with evidence of bias in sphere size estimates. Similar trends were observed in the second phantom. CONCLUSION A novel biomimetic phantom has been developed and shown to be stable over 10 months. It is envisaged that such phantoms will be used for further investigation of microstructural models relevant to characterizing tumor tissue, and may also find application in evaluating acquisition protocols and comparing DW-MRI-derived biomarkers obtained from different scanners at different sites. Magn Reson Med 80:147-158, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
|
10
|
ESTRO ACROP: Technology for precision small animal radiotherapy research: Optimal use and challenges. Radiother Oncol 2018; 126:471-478. [PMID: 29269093 DOI: 10.1016/j.radonc.2017.11.016] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 11/21/2017] [Indexed: 11/30/2022]
Abstract
Many radiotherapy research centers have recently installed novel research platforms enabling the investigation of the radiation response of tumors and normal tissues in small animal models, possibly in combination with other treatment modalities. Many more research institutes are expected to follow in the coming years. These novel platforms are capable of mimicking human radiotherapy more closely than older technology. To facilitate the optimal use of these novel integrated precision irradiators and various small animal imaging devices, and to maximize the impact of the associated research, the ESTRO committee on coordinating guidelines ACROP (Advisory Committee in Radiation Oncology Practice) has commissioned a report to review the state of the art of the technology used in this new field of research, and to issue recommendations. This report discusses the combination of precision irradiation systems, small animal imaging (CT, MRI, PET, SPECT, bioluminescence) systems, image registration, treatment planning, and data processing. It also provides guidelines for reporting on studies.
Collapse
|
11
|
Validation of diffusion measurements obtained on a 0.35T MR in Malawi: Important insights for radiologists in low income settings with low field MRI. Magn Reson Imaging 2017; 45:120-128. [PMID: 29031584 DOI: 10.1016/j.mri.2017.10.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 10/09/2017] [Accepted: 10/10/2017] [Indexed: 12/11/2022]
Abstract
PURPOSE To investigate the reliability of diffusion weighted image (DWI) measurements obtained on a 0.35T MR scanner in Malawi for malaria research. MATERIALS AND METHODS The same healthy volunteers (n=6) were scanned on a 0.35T MR scanner in Malawi and a 3T scanner in the US. Three subjects had two repeated DWI scans at 0.35T. Due to scanner constraints, only three diffusion gradient directions for DWI on 0.35T could be obtained. An apparent diffusion coefficient (ADC) map was reconstructed from the 0.35T and the result was compared to standard DWI acquisition on the 3T scanner. The mean ADC from 15 different regions and the voxel-wise coefficient of variation (CV) were calculated to investigate the intra-scanner and inter-scanner variability. Reproducibility was calculated using intra-class correlation coefficient (ICC). RESULTS The 0.35T intra-scanner ADC repeatability was high for all three subjects with repeated scans (ICC>0.7). The intra-scanner correlation between repeated scans was also high (r>0.67, p< 0.01). Comparing the ADC findings from the 0.35T and 3T MRs, the high inter-scanner correlation suggested that the 0.35T ADC results were valid (ICC>0.7, r>0.5, p<0.01). Voxel-wise CV revealed a few regions with larger variation (CV>20%), which were primarily located in peripheral regions and the boundary of lateral ventricles, and likely due to partial volume effects in low field scans. CONCLUSION These findings support the validity of DWI obtained from low field MR scanners used in many low income countries.
Collapse
|
12
|
Diffusion-weighted MRI of breast lesions: a prospective clinical investigation of the quantitative imaging biomarker characteristics of reproducibility, repeatability, and diagnostic accuracy. NMR IN BIOMEDICINE 2016; 29:1445-1453. [PMID: 27553252 DOI: 10.1002/nbm.3596] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 07/08/2016] [Accepted: 07/08/2016] [Indexed: 06/06/2023]
Abstract
Diffusion-weighted MRI (DWI) provides insights into tissue microstructure by visualization and quantification of water diffusivity. Quantitative evaluation of the apparent diffusion coefficient (ADC) obtained from DWI has been proven helpful for differentiating between malignant and benign breast lesions, for cancer subtyping in breast cancer patients, and for prediction of response to neoadjuvant chemotherapy. However, to further establish DWI of breast lesions it is important to evaluate the quantitative imaging biomarker (QIB) characteristics of reproducibility, repeatability, and diagnostic accuracy. In this intra-individual prospective clinical study 40 consecutive patients with suspicious findings, scheduled for biopsy, underwent an identical 3T breast MRI protocol of the breast on two consecutive days (>24 h). Mean ADC of target lesions was assessed (two independent readers) in four separate sessions. Reproducibility, repeatability, and diagnostic accuracy between examinations (E1, E2), readers (R1, R2), and measurements (M1, M2) were assessed with intraclass correlation coefficients (ICCs), coefficients of variation (CVs), Bland-Altman plots, and receiver operating characteristic (ROC) analysis with calculation of the area under the ROC curve (AUC). The standard of reference was either histopathology (n = 38) or imaging follow-up of up to 24 months (n = 2). Eighty breast MRI examinations (median E1-E2, 2 ± 1.7 days, 95% confidence interval (CI) 1-2 days, range 1-11 days) in 40 patients (mean age 56, standard deviation (SD) ±14) were evaluated. In 55 target lesions (mean size 25.2 ± 20.8 (SD) mm, range 6-106 mm), mean ADC values were significantly (P < 0.0001) higher in benign (1.38, 95% CI 1.27-1.49 × 10(-3) mm(2) /s) compared with malignant (0.86, 95% CI 0.81-0.91 × 10(-) (3) mm(2) /s) lesions. Reproducibility and repeatability showed high agreement for repeated examinations, readers, and measurements (all ICCs >0.9, CVs 3.2-8%), indicating little variation. Bland-Altman plots demonstrated no systematic differences, and diagnostic accuracy was not significantly different in the two repeated examinations (all ROC curves >0.91, P > 0.05). High reproducibility, repeatability, and diagnostic accuracy of DWI provide reliable characteristics for its use as a potential QIB, to further improve breast lesion detection, characterization, and treatment monitoring of breast lesions.
Collapse
|
13
|
Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility. World J Radiol 2016; 8:21-49. [PMID: 26834942 PMCID: PMC4731347 DOI: 10.4329/wjr.v8.i1.21] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 11/10/2015] [Accepted: 12/07/2015] [Indexed: 02/06/2023] Open
Abstract
There is considerable disparity in the published apparent diffusion coefficient (ADC) values across different anatomies. Institutions are increasingly assessing repeatability and reproducibility of the derived ADC to determine its variation, which could potentially be used as an indicator in determining tumour aggressiveness or assessing tumour response. In this manuscript, a review of selected articles published to date in healthy extra-cranial body diffusion-weighted magnetic resonance imaging is presented, detailing reported ADC values and discussing their variation across different studies. In total 115 studies were selected including 28 for liver parenchyma, 15 for kidney (renal parenchyma), 14 for spleen, 13 for pancreatic body, 6 for gallbladder, 13 for prostate, 13 for uterus (endometrium, myometrium, cervix) and 13 for fibroglandular breast tissue. Median ADC values in selected studies were found to be 1.28 × 10(-3) mm(2)/s in liver, 1.94 × 10(-3) mm(2)/s in kidney, 1.60 × 10(-3) mm(2)/s in pancreatic body, 0.85 × 10(-3) mm(2)/s in spleen, 2.73 × 10(-3) mm(2)/s in gallbladder, 1.64 × 10(-3) mm(2)/s and 1.31 × 10(-3) mm(2)/s in prostate peripheral zone and central gland respectively (combined median value of 1.54×10(-3) mm(2)/s), 1.44 × 10(-3) mm(2)/s in endometrium, 1.53 × 10(-3) mm(2)/s in myometrium, 1.71 × 10(-3) mm(2)/s in cervix and 1.92 × 10(-3) mm(2)/s in breast. In addition, six phantom studies and thirteen in vivo studies were summarized to compare repeatability and reproducibility of the measured ADC. All selected phantom studies demonstrated lower intra-scanner and inter-scanner variation compared to in vivo studies. Based on the findings of this manuscript, it is recommended that protocols need to be optimised for the body part studied and that system-induced variability must be established using a standardized phantom in any clinical study. Reproducibility of the measured ADC must also be assessed in a volunteer population, as variations are far more significant in vivo compared with phantom studies.
Collapse
|