1
|
De A, Jee JP, Park YJ. Why Perfluorocarbon nanoparticles encounter bottlenecks in clinical translation despite promising oxygen carriers? Eur J Pharm Biopharm 2024; 199:114292. [PMID: 38636883 DOI: 10.1016/j.ejpb.2024.114292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 03/23/2024] [Accepted: 04/15/2024] [Indexed: 04/20/2024]
Abstract
Artificial Oxygen Carriers (AOCs) have emerged as ground-breaking biomedical solutions, showcasing tremendous potential for enhancing human health and saving lives. Perfluorocarbon (PFC)-based AOCs, in particular, have garnered significant interest among researchers, leading to numerous clinical trials since the 1980 s. However, despite decades of exploration, the success rate has remained notably limited. This comprehensive review article delves into the landscape of clinical trials involving PFC compounds, shedding light on the challenges and factors contributing to the lack of clinical success with PFC nanoparticles till date. By scrutinizing the existing trials, the article aims to uncover the underlying issues like pharmacological side effects of the PFC and the nanomaterials used for the designing, complex formulation strategy and poor clinical trial designs of the formulation. More over each generation of the PFC formulation were discussed with details for their failure in the clinical trials limitations that block the path of PFC-based AOCs' full potential. Furthermore, the review emphasizes a forward-looking approach by outlining the future pathways and strategies essential for achieving success in clinical trials. AOCs require advanced yet biocompatible single-componentformulations. The new trend might be a novel drug delivery technique, like gel emulsion or reverse PFC emulsion with fluoro surfactants. Most importantly, well-planned clinical trials may end in a success story.
Collapse
Affiliation(s)
- Anindita De
- College of Pharmacy, Ajou University, 206 Worldcup-ro , Yeongtong-gu, Suwon-si 16499, Republic of Korea.
| | - Jun-Pil Jee
- College of Pharmacy, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| | - Young-Joon Park
- College of Pharmacy, Ajou University, 206 Worldcup-ro , Yeongtong-gu, Suwon-si 16499, Republic of Korea; Research Center, IMDpharm Inc., 17 Daehak 4-ro, Yeongtong-gu, Suwon-si 16226, Korea.
| |
Collapse
|
2
|
Sherstyukova E, Sergunova V, Kandrashina S, Chernysh A, Inozemtsev V, Lomakina G, Kozlova E. Red Blood Cell Storage with Xenon: Safe or Disruption? Cells 2024; 13:411. [PMID: 38474375 DOI: 10.3390/cells13050411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/21/2024] [Accepted: 02/23/2024] [Indexed: 03/14/2024] Open
Abstract
Xenon, an inert gas commonly used in medicine, has been considered as a potential option for prolonged preservation of donor packed red blood cells (pRBCs) under hypoxic conditions. This study aimed to investigate how xenon affects erythrocyte parameters under prolonged storage. In vitro model experiments were performed using two methods to create hypoxic conditions. In the first method, xenon was introduced into bags of pRBCs which were then stored for 42 days, while in the second method, xenon was added to samples in glass tubes. The results of our experiment showed that the presence of xenon resulted in notable alterations in erythrocyte morphology, similar to those observed under standard storage conditions. For pRBC bags, hemolysis during storage with xenon exceeded the acceptable limit by a factor of six, whereas the closed-glass-tube experiment showed minimal hemolysis in samples exposed to xenon. Notably, the production of deoxyhemoglobin was specific to xenon exposure in both cell suspension and hemolysate. However, this study did not provide evidence for the purported protective properties of xenon.
Collapse
Affiliation(s)
- Ekaterina Sherstyukova
- Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, V.A. Negovsky Research Institute of General Reanimatology, 107031 Moscow, Russia
| | - Viktoria Sergunova
- Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, V.A. Negovsky Research Institute of General Reanimatology, 107031 Moscow, Russia
| | - Snezhanna Kandrashina
- Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, V.A. Negovsky Research Institute of General Reanimatology, 107031 Moscow, Russia
| | - Aleksandr Chernysh
- Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, V.A. Negovsky Research Institute of General Reanimatology, 107031 Moscow, Russia
| | - Vladimir Inozemtsev
- Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, V.A. Negovsky Research Institute of General Reanimatology, 107031 Moscow, Russia
| | - Galina Lomakina
- Faculty of Chemistry, Lomonosov Moscow State University, Lenin Hills 1/3, 119991 Moscow, Russia
| | - Elena Kozlova
- Department of Medical and Biological Physics, Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia
| |
Collapse
|
3
|
Batarchuk V, Shepelytskyi Y, Grynko V, Kovacs AH, Hodgson A, Rodriguez K, Aldossary R, Talwar T, Hasselbrink C, Ruset IC, DeBoef B, Albert MS. Hyperpolarized Xenon-129 Chemical Exchange Saturation Transfer (HyperCEST) Molecular Imaging: Achievements and Future Challenges. Int J Mol Sci 2024; 25:1939. [PMID: 38339217 PMCID: PMC10856220 DOI: 10.3390/ijms25031939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 01/25/2024] [Accepted: 01/28/2024] [Indexed: 02/12/2024] Open
Abstract
Molecular magnetic resonance imaging (MRI) is an emerging field that is set to revolutionize our perspective of disease diagnosis, treatment efficacy monitoring, and precision medicine in full concordance with personalized medicine. A wide range of hyperpolarized (HP) 129Xe biosensors have been recently developed, demonstrating their potential applications in molecular settings, and achieving notable success within in vitro studies. The favorable nuclear magnetic resonance properties of 129Xe, coupled with its non-toxic nature, high solubility in biological tissues, and capacity to dissolve in blood and diffuse across membranes, highlight its superior role for applications in molecular MRI settings. The incorporation of reporters that combine signal enhancement from both hyperpolarized 129Xe and chemical exchange saturation transfer holds the potential to address the primary limitation of low sensitivity observed in conventional MRI. This review provides a summary of the various applications of HP 129Xe biosensors developed over the last decade, specifically highlighting their use in MRI. Moreover, this paper addresses the evolution of in vivo applications of HP 129Xe, discussing its potential transition into clinical settings.
Collapse
Affiliation(s)
- Viktoriia Batarchuk
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
| | - Yurii Shepelytskyi
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
| | - Vira Grynko
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
- Chemistry and Materials Science Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Antal Halen Kovacs
- Applied Life Science Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Aaron Hodgson
- Physics Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Karla Rodriguez
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
| | - Ruba Aldossary
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
| | - Tanu Talwar
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
| | - Carson Hasselbrink
- Chemistry & Biochemistry Department, California Polytechnic State University, San Luis Obispo, CA 93407-005, USA
| | | | - Brenton DeBoef
- Department of Chemistry, University of Rhode Island, Kingston, RI 02881, USA
| | - Mitchell S. Albert
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada; (V.B.)
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 6V4, Canada
- Faculty of Medical Sciences, Northern Ontario School of Medicine, Thunder Bay, ON P7B 5E1, Canada
| |
Collapse
|
4
|
Ohno Y, Ozawa Y, Nagata H, Ueda T, Yoshikawa T, Takenaka D, Koyama H. Lung Magnetic Resonance Imaging: Technical Advancements and Clinical Applications. Invest Radiol 2024; 59:38-52. [PMID: 37707840 DOI: 10.1097/rli.0000000000001017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/15/2023]
Abstract
ABSTRACT Since lung magnetic resonance imaging (MRI) became clinically available, limited clinical utility has been suggested for applying MRI to lung diseases. Moreover, clinical applications of MRI for patients with lung diseases or thoracic oncology may vary from country to country due to clinical indications, type of health insurance, or number of MR units available. Because of this situation, members of the Fleischner Society and of the Japanese Society for Magnetic Resonance in Medicine have published new reports to provide appropriate clinical indications for lung MRI. This review article presents a brief history of lung MRI in terms of its technical aspects and major clinical indications, such as (1) what is currently available, (2) what is promising but requires further validation or evaluation, and (3) which developments warrant research-based evaluations in preclinical or patient studies. We hope this article will provide Investigative Radiology readers with further knowledge of the current status of lung MRI and will assist them with the application of appropriate protocols in routine clinical practice.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- From the Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y. Ohno); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y. Ohno and H.N.); Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y. Ozawa and T.U.); Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Hyogo, Japan (T.Y., D.T.); and Department of Radiology, Advanced Diagnostic Medical Imaging, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (H.K.)
| | | | | | | | | | | | | |
Collapse
|
5
|
Nakamura H, Hirai T, Kurosawa H, Hamada K, Matsunaga K, Shimizu K, Konno S, Muro S, Fukunaga K, Nakano Y, Kuwahira I, Hanaoka M. Current advances in pulmonary functional imaging. Respir Investig 2024; 62:49-65. [PMID: 37948969 DOI: 10.1016/j.resinv.2023.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 08/26/2023] [Accepted: 09/07/2023] [Indexed: 11/12/2023]
Abstract
Recent advances in imaging analysis have enabled evaluation of ventilation and perfusion in specific regions by chest computed tomography (CT) and magnetic resonance imaging (MRI), in addition to modalities including dynamic chest radiography, scintigraphy, positron emission tomography (PET), ultrasound, and electrical impedance tomography (EIT). In this review, an overview of current functional imaging techniques is provided for each modality. Advances in chest CT have allowed for the analysis of local volume changes and small airway disease in addition to emphysema, using the Jacobian determinant and parametric response mapping with inspiratory and expiratory images. Airway analysis can reveal characteristics of airway lesions in chronic obstructive pulmonary disease (COPD) and bronchial asthma, and the contribution of dysanapsis to obstructive diseases. Chest CT is also employed to measure pulmonary blood vessels, interstitial lung abnormalities, and mediastinal and chest wall components including skeletal muscle and bone. Dynamic CT can visualize lung deformation in respective portions. Pulmonary MRI has been developed for the estimation of lung ventilation and perfusion, mainly using hyperpolarized 129Xe. Oxygen-enhanced and proton-based MRI, without a polarizer, has potential clinical applications. Dynamic chest radiography is gaining traction in Japan for ventilation and perfusion analysis. Single photon emission CT can be used to assess ventilation-perfusion (V˙/Q˙) mismatch in pulmonary vascular diseases and COPD. PET/CT V˙/Q˙ imaging has also been demonstrated using "Galligas". Both ultrasound and EIT can detect pulmonary edema caused by acute respiratory distress syndrome. Familiarity with these functional imaging techniques will enable clinicians to utilize these systems in clinical practice.
Collapse
Affiliation(s)
- Hidetoshi Nakamura
- Department of Respiratory Medicine, Saitama Medical University, Saitama, Japan.
| | - Toyohiro Hirai
- Department of Respiratory Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Hajime Kurosawa
- Center for Environmental Conservation and Research Safety and Department of Occupational Health, Tohoku University School of Medicine, Sendai, Japan
| | - Kazuki Hamada
- Department of Respiratory Medicine and Infectious Disease, Graduate School of Medicine, Yamaguchi University, Ube, Japan
| | - Kazuto Matsunaga
- Department of Respiratory Medicine and Infectious Disease, Graduate School of Medicine, Yamaguchi University, Ube, Japan
| | - Kaoruko Shimizu
- Department of Respiratory Medicine, Faculty of Medicine, Hokkaido University, Sapporo, Japan
| | - Satoshi Konno
- Department of Respiratory Medicine, Faculty of Medicine, Hokkaido University, Sapporo, Japan
| | - Shigeo Muro
- Department of Respiratory Medicine, Nara Medical University, Nara, Japan
| | - Koichi Fukunaga
- Division of Pulmonary Medicine, Department of Medicine, Keio University School of Medicine, Tokyo, Japan
| | - Yasutaka Nakano
- Division of Respiratory Medicine, Department of Internal Medicine, Shiga University of Medical Science, Otsu, Japan
| | - Ichiro Kuwahira
- Division of Pulmonary Medicine, Department of Medicine, Tokai University Tokyo Hospital, Tokyo, Japan
| | - Masayuki Hanaoka
- First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Japan
| |
Collapse
|
6
|
Alam FS, Zanette B, Munidasa S, Braganza S, Li D, Woods JC, Ratjen F, Santyr G. Intra- and Inter-visit Repeatability of 129 Xenon Multiple-Breath Washout MRI in Children With Stable Cystic Fibrosis Lung Disease. J Magn Reson Imaging 2023; 58:936-948. [PMID: 36786650 DOI: 10.1002/jmri.28638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 01/25/2023] [Accepted: 01/26/2023] [Indexed: 02/15/2023] Open
Abstract
BACKGROUND Multiple-breath washout (MBW) 129 Xe MRI (MBW Xe-MRI) is a promising technique for following pediatric cystic fibrosis (CF) lung disease progression. However, its repeatability in stable CF needs to be established to use it as an outcome measure for novel therapies. PURPOSE To assess intravisit and intervisit repeatability of MBW Xe-MRI in healthy and CF children. STUDY TYPE Prospective, longitudinal cohort study. SUBJECTS A total of 18 pediatric subjects (7 healthy, 11 CF). FIELD STRENGTH/SEQUENCE A 3 T/2D coronal hyperpolarized (HP) 129 Xe images using GRE sequence. ASSESSMENT All subjects completed MBW Xe-MRI, pulmonary function tests (PFTs) (spirometry, nitrogen [N2 ] MBW for lung clearance index [LCI]) and ventilation defect percent (VDP) at baseline (visit 1) and 1-month after. Fractional ventilation (FV), coefficient of variation (CoVFV ) maps were calculated from MBW Xe-MRI data acquired between intervening air washout breaths performed after an initial xenon breath-hold. Skewness of FV and CoVFV map distributions was also assessed. STATISTICAL TESTS Repeatability: intraclass correlation coefficients (ICC), within-subject coefficient of variation (CV%), repeatability coefficient (CR). Agreement: Bland-Altman. For correlations between MBW Xe-MRI, VDP and PFTs: Spearman's correlation. Significance threshold: P < 0.05. RESULTS For FV, intravisit median [IQR] ICC was high in both healthy (0.94 [0.48, 0.99]) and CF (0.83 [0.04, 0.97]) subjects. CoVFV also had good intravisit ICC in healthy (0.92 [0.42, 0.99]) and CF (0.79 [0.02, 0.96]) subjects. Similarly, for FV, intervisit ICC was high in health (0.94 [0.68, 0.99]) and CF (0.89 [0.61, 0.97]). CoVFV also had good intervisit ICC in health (0.92 [0.42, 0.99]) and CF (0.78 [0.26, 0.94]). FV had better intervisit repeatability than VDP. CoVFV correlated significantly with LCI (R = 0.56). Skewness of FV distributions significantly distinguished between cohorts at baseline. DATA CONCLUSION MBW Xe-MRI had high intravisit and intervisit repeatability in healthy and stable CF subjects. CoVFV correlated with LCI, suggesting the importance of ventilation heterogeneity to early CF. EVIDENCE LEVEL 1. TECHNICAL EFFICACY Stage 2.
Collapse
Affiliation(s)
- Faiyza S Alam
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Brandon Zanette
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Samal Munidasa
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Sharon Braganza
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Daniel Li
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Jason C Woods
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital, Cincinnati, Ohio, USA
| | - Felix Ratjen
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
- Division of Respirology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Giles Santyr
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| |
Collapse
|
7
|
Mikowska L, Grynko V, Shepelytskyi Y, Ruset IC, Deschamps J, Aalto H, Targosz-Korecka M, Balamore D, Harańczyk H, Albert MS. Revealing a Third Dissolved-Phase Xenon-129 Resonance in Blood Caused by Hemoglobin Glycation. Int J Mol Sci 2023; 24:11311. [PMID: 37511071 PMCID: PMC10380088 DOI: 10.3390/ijms241411311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 07/06/2023] [Accepted: 07/10/2023] [Indexed: 07/30/2023] Open
Abstract
Hyperpolarized (HP) xenon-129 (129Xe), when dissolved in blood, has two NMR resonances: one in red blood cells (RBC) and one in plasma. The impact of numerous blood components on these resonances, however, has not yet been investigated. This study evaluates the effects of elevated glucose levels on the chemical shift (CS) and T2* relaxation times of HP 129Xe dissolved in sterile citrated sheep blood for the first time. HP 129Xe was mixed with sheep blood samples premixed with a stock glucose solution using a liquid-gas exchange module. Magnetic resonance spectroscopy was performed on a 3T clinical MRI scanner using a custom-built quadrature dual-tuned 129Xe/1H coil. We observed an additional resonance for the RBCs (129Xe-RBC1) for the increased glucose levels. The CS of 129Xe-RBC1 and 129Xe-plasma peaks did not change with glucose levels, while the CS of 129Xe-RBC2 (original RBC resonance) increased linearly at a rate of 0.015 ± 0.002 ppm/mM with glucose level. 129Xe-RBC1 T2* values increased nonlinearly from 1.58 ± 0.24 ms to 2.67 ± 0.40 ms. As a result of the increased glucose levels in blood samples, the novel additional HP 129Xe dissolved phase resonance was observed in blood and attributed to the 129Xe bound to glycated hemoglobin (HbA1c).
Collapse
Affiliation(s)
- Lutosława Mikowska
- Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, 30-348 Krakow, Poland
| | - Vira Grynko
- Chemistry and Material Science Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 7A5, Canada
| | - Yurii Shepelytskyi
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 7A5, Canada
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | | | - Joseph Deschamps
- Applied Life Sciences Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Hannah Aalto
- Applied Life Sciences Program, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
| | - Marta Targosz-Korecka
- Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, 30-348 Krakow, Poland
| | - Dilip Balamore
- Department of Engineering, Physics and Technology, Nassau Community College, New York, NY 11530, USA
| | - Hubert Harańczyk
- Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, 30-348 Krakow, Poland
| | - Mitchell S Albert
- Thunder Bay Regional Health Research Institute, Thunder Bay, ON P7B 7A5, Canada
- Chemistry Department, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
- Faculty of Medical Sciences, Northern Ontario School of Medicine University, Thunder Bay, ON P3E 2C6, Canada
| |
Collapse
|
8
|
Zanette B, Greer MLC, Moraes TJ, Ratjen F, Santyr G. The argument for utilising magnetic resonance imaging as a tool for monitoring lung structure and function in pediatric patients. Expert Rev Respir Med 2023; 17:527-538. [PMID: 37491192 DOI: 10.1080/17476348.2023.2241355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 07/06/2023] [Accepted: 07/24/2023] [Indexed: 07/27/2023]
Abstract
INTRODUCTION Although historically challenging to perform in the lung, technological advancements have made Magnetic Resonance Imaging (MRI) increasingly applicable for pediatric pulmonary imaging. Furthermore, a wide array of functional imaging techniques has become available that may be leveraged alongside structural imaging for increasingly sensitive biomarkers, or as outcome measures in the evaluation of novel therapies. AREAS COVERED In this review, recent technical advancements and modern methodologies for structural and functional lung MRI are described. These include ultrashort echo time (UTE) MRI, free-breathing contrast agent-free, functional lung MRI, and hyperpolarized gas MRI, amongst other techniques. Specific examples of the application of these methods in children are provided, principally drawn from recent research in asthma, bronchopulmonary dysplasia, and cystic fibrosis. EXPERT OPINION Pediatric lung MRI is rapidly growing, and is well poised for clinical utilization, as well as continued research into early disease detection, disease processes, and novel treatments. Structure/function complementarity makes MRI especially attractive as a tool for increased adoption in the evaluation of pediatric lung disease. Looking toward the future, novel technologies, such as low-field MRI and artificial intelligence, mitigate some of the traditional drawbacks of lung MRI and will aid in improving access to MRI in general, potentially spurring increased adoption and demand for pulmonary MRI in children.
Collapse
Affiliation(s)
- Brandon Zanette
- Translational Medicine Program, The Hospital for Sick Children, Toronto, ON, Canada
| | - Mary-Louise C Greer
- Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Theo J Moraes
- Translational Medicine Program, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Pediatrics, Hospital for Sick Children, Toronto, ON, Canada
| | - Felix Ratjen
- Translational Medicine Program, The Hospital for Sick Children, Toronto, ON, Canada
- Division of Respiratory Medicine, The Hospital for Sick Children, Toronto, ON, Canada
| | - Giles Santyr
- Translational Medicine Program, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
9
|
Radadia N, Friedlander Y, Priel E, Konyer NB, Huang C, Jamal M, Farncombe T, Marriott C, Finley C, Agzarian J, Dolovich M, Noseworthy MD, Nair P, Shargall Y, Svenningsen S. Comparison of ventilation defects quantified by Technegas SPECT and hyperpolarized 129Xe MRI. Front Physiol 2023; 14:1133334. [PMID: 37234422 PMCID: PMC10206636 DOI: 10.3389/fphys.2023.1133334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 04/03/2023] [Indexed: 05/28/2023] Open
Abstract
Introduction: The ideal contrast agents for ventilation SPECT and MRI are Technegas and 129Xe gas, respectively. Despite increasing interest in the clinical utility of ventilation imaging, these modalities have not been directly compared. Therefore, our objective was to compare the ventilation defect percent (VDP) assessed by Technegas SPECT and hyperpolarized 129Xe MRI in patients scheduled to undergo lung cancer resection with and without pre-existing obstructive lung disease. Methods: Forty-one adults scheduled to undergo lung cancer resection performed same-day Technegas SPECT, hyperpolarized 129Xe MRI, spirometry, and diffusing capacity of the lung for carbon monoxide (DLCO). Ventilation abnormalities were quantified as the VDP using two different methods: adaptive thresholding (VDPT) and k-means clustering (VDPK). Correlation and agreement between VDP quantified by Technegas SPECT and 129Xe MRI were determined by Spearman correlation and Bland-Altman analysis, respectively. Results: VDP measured by Technegas SPECT and 129Xe MRI were correlated (VDPT: r = 0.48, p = 0.001; VDPK: r = 0.63, p < 0.0001). A 2.0% and 1.6% bias towards higher Technegas SPECT VDP was measured using the adaptive threshold method (VDPT: 23.0% ± 14.0% vs. 21.0% ± 5.2%, p = 0.81) and k-means method (VDPK: 9.4% ± 9.4% vs. 7.8% ± 10.0%, p = 0.02), respectively. For both modalities, higher VDP was correlated with lower FEV1/FVC (SPECT VDPT: r = -0.38, p = 0.01; MRI VDPK: r = -0.46, p = 0.002) and DLCO (SPECT VDPT: r = -0.61, p < 0.0001; MRI VDPK: r = -0.68, p < 0.0001). Subgroup analysis revealed that VDP measured by both modalities was significantly higher for participants with COPD (n = 13) than those with asthma (n = 6; SPECT VDPT: p = 0.007, MRI VDPK: p = 0.006) and those with no history of obstructive lung disease (n = 21; SPECT VDPT: p = 0.0003, MRI VDPK: p = 0.0003). Discussion: The burden of ventilation defects quantified by Technegas SPECT and 129Xe MRI VDP was correlated and greater in participants with COPD when compared to those without. Our observations indicate that, despite substantial differences between the imaging modalities, quantitative assessment of ventilation defects by Technegas SPECT and 129Xe MRI is comparable.
Collapse
Affiliation(s)
- Nisarg Radadia
- Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, Canada
| | - Yonni Friedlander
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Imaging Research Centre, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Eldar Priel
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Norman B. Konyer
- Imaging Research Centre, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Chynna Huang
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Mobin Jamal
- Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, Canada
| | - Troy Farncombe
- Department of Radiology, McMaster University, Hamilton, ON, Canada
- Department of Nuclear Medicine, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Christopher Marriott
- Department of Radiology, McMaster University, Hamilton, ON, Canada
- Department of Nuclear Medicine, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Christian Finley
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - John Agzarian
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Myrna Dolovich
- Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, Canada
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Imaging Research Centre, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Michael D. Noseworthy
- Imaging Research Centre, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Department of Radiology, McMaster University, Hamilton, ON, Canada
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON, Canada
| | - Parameswaran Nair
- Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, Canada
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| | - Yaron Shargall
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Division of Thoracic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Sarah Svenningsen
- Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, Canada
- Firestone Institute for Respiratory Health, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
- Imaging Research Centre, St. Joseph’s Healthcare Hamilton, Hamilton, ON, Canada
| |
Collapse
|
10
|
Crémillieux Y. Editorial for "Volume-Controlled 19 F MR Ventilation Imaging of Fluorinated Gas". J Magn Reson Imaging 2023; 57:1129-1130. [PMID: 35943284 DOI: 10.1002/jmri.28384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 07/20/2022] [Indexed: 11/09/2022] Open
Affiliation(s)
- Yannick Crémillieux
- Institut des Sciences Moléculaires, UMR CNRS 5255, Université de Bordeaux, Bordeaux, France
| |
Collapse
|
11
|
Zanette B, Munidasa S, Friedlander Y, Ratjen F, Santyr G. A 3D stack-of-spirals approach for rapid hyperpolarized 129 Xe ventilation mapping in pediatric cystic fibrosis lung disease. Magn Reson Med 2023; 89:1083-1091. [PMID: 36433705 DOI: 10.1002/mrm.29505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 09/14/2022] [Accepted: 10/09/2022] [Indexed: 11/27/2022]
Abstract
PURPOSE To demonstrate the feasibility of a rapid 3D stack-of-spirals (3D-SoS) imaging acquisition for hyperpolarized 129 Xe ventilation mapping in healthy pediatric participants and pediatric cystic fibrosis (CF) participants, in comparison to conventional Cartesian multislice (2D) gradient-recalled echo (GRE) imaging. METHODS The 2D-GRE and 3D-SoS acquisitions were performed in 13 pediatric participants (5 healthy, 8 CF) during separate breath-holds. Images from both sequences were compared on the basis of ventilation defect percent (VDP) and other measures of image similarity. The nadir of transient oxygen saturation (SpO2 ) decline due to xenon breath-holding was measured with pulse oximetry, and expressed as a percent change relative to baseline. RESULTS 129 Xe ventilation images were acquired in a breath-hold of 1.2-1.8 s with the 3D-SoS sequence, compared to 6.2-8.8 s for 2D-GRE. Mean ± SD VDP measures for 2D-GRE and 3D-SoS sequences were 5.02 ± 1.06% and 5.28 ± 1.08% in healthy participants, and 18.05 ± 8.26% and 18.75 ± 6.74% in CF participants, respectively. Across all participants, the intraclass correlation coefficient of VDP measures for both sequences was 0.98 (95% confidence interval: 0.94-0.99). The percent change in SpO2 was reduced to -2.1 ± 2.7% from -5.2 ± 3.5% with the shorter 3D-SoS breath-hold. CONCLUSION Hyperpolarized 129 Xe ventilation imaging with 3D-SoS yielded images approximately five times faster than conventional 2D-GRE, reducing SpO2 desaturation and improving tolerability of the xenon administration. Analysis of VDP and other measures of image similarity demonstrate excellent agreement between images obtained with both sequences. 3D-SoS holds significant potential for reducing the acquisition time of hyperpolarized 129 Xe MRI, and/or increasing spatial resolution while adhering to clinical breath-hold constraints.
Collapse
Affiliation(s)
- Brandon Zanette
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Samal Munidasa
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Yonni Friedlander
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Felix Ratjen
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada.,Division of Respiratory Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Giles Santyr
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
12
|
Pavlova OS, Gulyaev MV, Gervits LL, Hurshkainen AA, Nikulin AV, Puchnin VM, Teploukhova ED, Kuropatkina TA, Anisimov NV, Medvedeva NA, Pirogov YA. Т 1 mapping of rat lungs in 19 F MRI using octafluorocyclobutane. Magn Reson Med 2023; 89:2318-2331. [PMID: 36744719 DOI: 10.1002/mrm.29606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 02/07/2023]
Abstract
PURPOSE To demonstrate the feasibility of using octafluorocyclobutane (OFCB, c-C4 F8 ) for T1 mapping of lungs in 19 F MRI. METHODS The study was performed at 7 T in three healthy rats and three rats with pulmonary hypertension. To increase the sensitivity of 19 F MRI, a bent-shaped RF coil with periodic metal strips structure was used. The double flip angle method was used to calculate normalized transmitting RF field (B1n + ) maps and for correcting T1 maps built with the variable flip angle (VFA) method. The ultrashort TE pulse sequence was applied for acquiring MR images throughout the study. RESULTS The dependencies of OFCB relaxation times on its partial pressure in mixtures with oxygen, air, helium, and argon were obtained. T1 of OFCB linearly depended on its partial pressure with the slope of about 0.35 ms/kPa in the case of free diffusion. RF field inhomogeneity leads to distortion of T1 maps built with the VFA method, and therefore to high standard deviation of T1 in these maps. To improve the accuracy of the T1 maps, the B1n + maps were applied for VFA correction. This contributed to a 2-3-fold decrease in the SD of T1 values in the corresponding maps compared with T1 maps calculated without the correction. Three-dimensional T1 maps were obtained, and the mean T1 in healthy rat lungs was 35 ± 10 ms, and in rat lungs with pulmonary hypertension - 41 ± 9 ms. CONCLUSION OFCB has a spin-rotational relaxation mechanism and can be used for 19 F T1 mapping of lungs. The calculated OFCB maps captured ventilation defects induced by edema.
Collapse
Affiliation(s)
- Olga S Pavlova
- Faculty of Medicine, Lomonosov Moscow State University, Moscow, Russia.,Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia
| | - Mikhail V Gulyaev
- Faculty of Medicine, Lomonosov Moscow State University, Moscow, Russia
| | - Lev L Gervits
- Nesmeyanov Institute of Organoelement Compounds of Russian Academy of Sciences, Moscow, Russia
| | - Anna A Hurshkainen
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Anton V Nikulin
- Center of Photonics and 2D Materials, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Viktor M Puchnin
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | | | | | | | | | - Yury A Pirogov
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia
| |
Collapse
|
13
|
Schiebler ML, Tsuchiya N, Hahn A, Fain S, Denlinger L, Jarjour N, Hoffman EA. Imaging Regional Airway Involvement of Asthma: Heterogeneity in Ventilation, Mucus Plugs and Remodeling. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1426:163-184. [PMID: 37464121 DOI: 10.1007/978-3-031-32259-4_8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/20/2023]
Abstract
The imaging of asthma using chest computed tomography (CT) is well-established (Jarjour et al., Am J Respir Crit Care Med 185(4):356-62, 2012; Castro et al., J Allergy Clin Immunol 128:467-78, 2011). Moreover, recent advances in functional imaging of the lungs with advanced computer analysis of both CT and magnetic resonance images (MRI) of the lungs have begun to play a role in quantifying regional obstruction. Specifically, quantitative measurements of the airways for bronchial wall thickening, luminal narrowing and distortion, the amount of mucus plugging, parenchymal density, and ventilation defects that could contribute to the patient's disease course are instructive for the entire care team. In this chapter, we will review common imaging methods and findings that relate to the heterogeneity of asthma. This information can help to guide treatment decisions. We will discuss mucous plugging, quantitative assessment of bronchial wall thickening, delta lumen phenomenon, parenchymal low-density lung on CT, and ventilation defect percentage on MRI as metrics for assessing regional ventilatory dysfunction.
Collapse
Affiliation(s)
- Mark L Schiebler
- Cardiothoracic imaging, Department of Radiology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA.
| | - Nanae Tsuchiya
- Department of Radiology, School of Medicine, University of the Ryukyus, Okinawa, Japan
| | - Andrew Hahn
- Department of Radiology, University of Iowa, Iowa City, IA, USA
| | - Sean Fain
- Department of Radiology, Biomedical Engineering, and Human Physiology, University of Iowa, Iowa City, IA, USA
| | - Loren Denlinger
- Department of Medicine, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA
| | - Nizar Jarjour
- Department of Medicine, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA
| | - Eric A Hoffman
- Departments of Radiology, Medicine and Biomedical Engineering, University of Iowa, Iowa City, IA, USA
| |
Collapse
|
14
|
Lopez Kolkovsky AL, Carlier PG, Marty B, Meyerspeer M. Interleaved and simultaneous multi-nuclear magnetic resonance in vivo. Review of principles, applications and potential. NMR IN BIOMEDICINE 2022; 35:e4735. [PMID: 35352440 PMCID: PMC9542607 DOI: 10.1002/nbm.4735] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 03/03/2022] [Accepted: 03/28/2022] [Indexed: 06/14/2023]
Abstract
Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi-nuclear acquisitions feasible. The advan-tages are a reduction of total scan time compared to sequential multi-nuclear acquisitions or that additional information from heteronuclear data is obtained at thesame time and anatomical position. Information content can be qualitatively increased by delivering a more comprehensive MR-based picture of a transient state (such as an exercise bout). Also, combiningnon-proton MR acquisitions with 1 Hinformation (e.g., dynamic shim updates and motion correction) can be used to improve data quality during long scans and benefits image coregistration. This work reviews the literature on interleaved and simultaneous multi-nuclear MRI and MRS in vivo. Prominent use cases for this methodology in clinical and research applications are brain and muscle, but studies have also been carried out in other targets, including the lung, knee, breast and heart. Simultaneous multi-nuclear measurements in the liver and kidney have also been performed, but exclusively in rodents. In this review, a consistent nomenclature is proposed, to help clarify the terminology used for this principle throughout the literature on in-vivo MR. An overview covers the basic principles, the technical requirements on the MR scanner and the implementations realised either by MR system vendors or research groups, from the early days until today. Considerations regarding the multi-tuned RF coils required and heteronuclear polarisation interactions are briefly discussed, and fields for future in-vivo applications for interleaved multi-nuclear MR pulse sequences are identified.
Collapse
Affiliation(s)
- Alfredo L. Lopez Kolkovsky
- NMR Laboratory, Neuromuscular Investigation CenterInstitute of MyologyParisFrance
- NMR laboratoryCEA, DRF, IBFJParisFrance
| | - Pierre G. Carlier
- NMR Laboratory, Neuromuscular Investigation CenterInstitute of MyologyParisFrance
- NMR laboratoryCEA, DRF, IBFJParisFrance
| | - Benjamin Marty
- NMR Laboratory, Neuromuscular Investigation CenterInstitute of MyologyParisFrance
- NMR laboratoryCEA, DRF, IBFJParisFrance
| | - Martin Meyerspeer
- High‐Field MR Center, Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| |
Collapse
|
15
|
Shepelytskyi Y, Grynko V, Rao MR, Li T, Agostino M, Wild JM, Albert MS. Hyperpolarized 129 Xe imaging of the brain: Achievements and future challenges. Magn Reson Med 2022; 88:83-105. [PMID: 35253919 PMCID: PMC9314594 DOI: 10.1002/mrm.29200] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 12/22/2021] [Accepted: 01/25/2022] [Indexed: 11/25/2022]
Abstract
Hyperpolarized (HP) xenon-129 (129 Xe) brain MRI is a promising imaging modality currently under extensive development. HP 129 Xe is nontoxic, capable of dissolving in pulmonary blood, and is extremely sensitive to the local environment. After dissolution in the pulmonary blood, HP 129 Xe travels with the blood flow to the brain and can be used for functional imaging such as perfusion imaging, hemodynamic response detection, and blood-brain barrier permeability assessment. HP 129 Xe MRI imaging of the brain has been performed in animals, healthy human subjects, and in patients with Alzheimer's disease and stroke. In this review, the overall progress in the field of HP 129 Xe brain imaging is discussed, along with various imaging approaches and pulse sequences used to optimize HP 129 Xe brain MRI. In addition, current challenges and limitations of HP 129 Xe brain imaging are discussed, as well as possible methods for their mitigation. Finally, potential pathways for further development are also discussed. HP 129 Xe MRI of the brain has the potential to become a valuable novel perfusion imaging technique and has the potential to be used in the clinical setting in the future.
Collapse
Affiliation(s)
- Yurii Shepelytskyi
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Vira Grynko
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada
| | - Madhwesha R Rao
- POLARIS, Unit of Academic Radiology, Department of IICD, University of Sheffield, Sheffield, UK
| | - Tao Li
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Martina Agostino
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Jim M Wild
- POLARIS, Unit of Academic Radiology, Department of IICD, University of Sheffield, Sheffield, UK.,Insigneo Institute for in Silico Medicine, Sheffield, UK
| | - Mitchell S Albert
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| |
Collapse
|
16
|
Bier EA, Alenezi F, Lu J, Wang Z, Mammarappallil JG, O'Sullivan-Murphy B, Erkanli A, Driehuys B, Rajagopal S. Noninvasive diagnosis of pulmonary hypertension with hyperpolarised 129Xe magnetic resonance imaging and spectroscopy. ERJ Open Res 2022; 8:00035-2022. [PMID: 35586448 PMCID: PMC9108963 DOI: 10.1183/23120541.00035-2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 03/10/2022] [Indexed: 11/23/2022] Open
Abstract
Background The diagnosis of pulmonary hypertension (PH) remains challenging. Pre- and post-capillary PH have different signatures on noninvasive 129Xe gas-exchange magnetic resonance imaging (MRI) and dynamic MR spectroscopy (MRS). We tested the accuracy of 129Xe MRI/MRS to diagnose PH status compared to right heart catheterisation (RHC). Methods 129Xe MRI/MRS from 93 subjects was used to develop a diagnostic algorithm, which was tested in 32 patients undergoing RHC on the same day (n=20) or within 5 months (42±40 days) (n=12). Three expert readers, blinded to RHC, used 129Xe MRI/MRS to classify subjects as pre-capillary PH, post-capillary PH, no PH and no interstitial lung disease (ILD), or ILD. Results For pre-capillary PH, 129Xe MRI/MRS diagnostic accuracy was 75% (95% CI 66–84) with a sensitivity of 67% (95% CI 54–79) and a specificity of 86% (95% CI 75–96); for post-capillary PH accuracy was 69% (95% CI 59–78) with sensitivity of 54% (95% CI 34–74) and specificity of 74% (95% CI 63–84). The model performed well in straightforward cases of pre-capillary PH but was less accurate in its diagnosis in the presence of mixed disease, particularly in the presence of ILD or combined post- and pre-capillary PH. Conclusion This study demonstrates the potential to develop 129Xe MRI/MRS into a modality with good accuracy in detecting pre- and post-capillary PH. Furthermore, the combination of 129Xe dynamic MRS and gas-exchange MRI uniquely provide concurrent, noninvasive assessment of both haemodynamics and gas-exchange impairment that may aid in the detection of PH. Diagnostic models using 129Xe MRI/MRS metrics can noninvasively detect pre-capillary PH, post-capillary PH and ILD. The combination of 129Xe MRI/MRS provides a comprehensive assessment of haemodynamics and gas-exchange impairment in individual patients.https://bit.ly/3tDJw5P
Collapse
Affiliation(s)
- Elianna A Bier
- Dept of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Fawaz Alenezi
- Division of Cardiology, Department of Medicine, Duke University Medical Center, Durham, NC, USA
| | - Junlan Lu
- Medical Physics Graduate Program, Duke University, Durham, NC, USA
| | - Ziyi Wang
- Dept of Biomedical Engineering, Duke University, Durham, NC, USA
| | | | | | - Alaattin Erkanli
- Dept of Biostatistics and Bioinformatics, Duke University, Durham, NC, USA
| | | | - Sudarshan Rajagopal
- Division of Cardiology, Department of Medicine, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
17
|
Abstract
Artificial intelligence (AI) is transforming the way we perform advanced imaging. From high-resolution image reconstruction to predicting functional response from clinically acquired data, AI is promising to revolutionize clinical evaluation of lung performance, pushing the boundary in pulmonary functional imaging for patients suffering from respiratory conditions. In this review, we overview the current developments and expound on some of the encouraging new frontiers. We focus on the recent advances in machine learning and deep learning that enable reconstructing images, quantitating, and predicting functional responses of the lung. Finally, we shed light on the potential opportunities and challenges ahead in adopting AI for functional lung imaging in clinical settings.
Collapse
Affiliation(s)
- Raúl San José Estépar
- Applied Chest Imaging Laboratory, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, United States
| |
Collapse
|
18
|
Bhattacharya I, Ramasawmy R, Javed A, Lowery M, Henry J, Mancini C, Machado T, Jones A, Julien-Williams P, Lederman RJ, Balaban RS, Chen MY, Moss J, Campbell-Washburn AE. Assessment of Lung Structure and Regional Function Using 0.55 T MRI in Patients With Lymphangioleiomyomatosis. Invest Radiol 2022; 57:178-186. [PMID: 34652290 PMCID: PMC9926400 DOI: 10.1097/rli.0000000000000832] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Contemporary lower-field magnetic resonance imaging (MRI) may offer advantages for lung imaging by virtue of the improved field homogeneity. The aim of this study was to evaluate the utility of lower-field MRI for combined morphologic imaging and regional lung function assessment. We evaluate low-field MRI in patients with lymphangioleiomyomatosis (LAM), a rare lung disease associated with parenchymal cysts and respiratory failure. MATERIALS AND METHODS We performed lung imaging on a prototype low-field (0.55 T) MRI system in 65 patients with LAM. T2-weighted imaging was used for assessment of lung morphology and to derive cyst scores, the percent of lung parenchyma occupied by cysts. Regional lung function was assessed using oxygen-enhanced MRI with breath-held ultrashort echo time imaging and inhaled 100% oxygen as a T1-shortening MR contrast agent. Measurements of percent signal enhancement from oxygen inhalation and percentage of lung with low oxygen enhancement, indicating functional deficits, were correlated with global pulmonary function test measurements taken within 2 days. RESULTS We were able to image cystic abnormalities using T2-weighted MRI in this patient population and calculate cyst score with strong correlation to computed tomography measurements (R = 0.86, P < 0.0001). Oxygen-enhancement maps demonstrated regional deficits in lung function of patients with LAM. Heterogeneity of oxygen enhancement between cysts was observed within individual patients. The percent low-enhancement regions showed modest, but significant, correlation with FEV1 (R = -0.37, P = 0.007), FEV1/FVC (R = -0.33, P = 0.02), and cyst score (R = 0.40, P = 0.02). The measured arterial blood ΔT1 between normoxia and hyperoxia, used as a surrogate for dissolved oxygen in blood, correlated with DLCO (R = -0.28, P = 0.03). CONCLUSIONS Using high-performance 0.55 T MRI, we were able to perform simultaneous imaging of pulmonary structure and regional function in patients with LAM.
Collapse
Affiliation(s)
- Ipshita Bhattacharya
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Margaret Lowery
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Jennifer Henry
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Christine Mancini
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Tania Machado
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Amanda Jones
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Patricia Julien-Williams
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Robert S Balaban
- Systems Biology Center, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Marcus Y Chen
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Joel Moss
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| |
Collapse
|
19
|
Bak SH, Kim C, Kim CH, Ohno Y, Lee HY. Magnetic resonance imaging for lung cancer: a state-of-the-art review. PRECISION AND FUTURE MEDICINE 2022. [DOI: 10.23838/pfm.2021.00170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
20
|
Practical protocol for lung magnetic resonance imaging and common clinical indications. Pediatr Radiol 2022; 52:295-311. [PMID: 34037828 PMCID: PMC8150155 DOI: 10.1007/s00247-021-05090-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/23/2021] [Accepted: 04/20/2021] [Indexed: 12/22/2022]
Abstract
Imaging speed, spatial resolution and availability have made CT the favored cross-sectional imaging modality for evaluating various respiratory diseases of children - but only for the price of a radiation exposure. MRI is increasingly being appreciated as an alternative to CT, not only for offering three-dimensional (3-D) imaging without radiation exposure at only slightly inferior spatial resolution, but also for its superior soft-tissue contrast and exclusive morpho-functional imaging capacities beyond the scope of CT. Continuing technical improvements and experience with this so far under-utilized modality contribute to a growing acceptance of MRI for an increasing number of indications, in particular for pediatric patients. This review article provides the reader with practical easy-to-use protocols for common clinical indications in children. This is intended to encourage pediatric radiologists to appreciate the new horizons for applications of this rapidly evolving technique in the field of pediatric respiratory diseases.
Collapse
|
21
|
Bhattacharya I, Ramasawmy R, Javed A, Chen MY, Benkert T, Majeed W, Lederman RJ, Moss J, Balaban RS, Campbell-Washburn AE. Oxygen-enhanced functional lung imaging using a contemporary 0.55 T MRI system. NMR IN BIOMEDICINE 2021; 34:e4562. [PMID: 34080253 PMCID: PMC8377594 DOI: 10.1002/nbm.4562] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 04/30/2021] [Accepted: 05/04/2021] [Indexed: 05/14/2023]
Abstract
The purpose of this study was to evaluate oxygen-enhanced pulmonary imaging at 0.55 T with 3D stack-of-spirals ultrashort-TE (UTE) acquisition. Oxygen-enhanced pulmonary MRI offers the measurement of regional lung ventilation and perfusion using inhaled oxygen as a contrast agent. Low-field MRI systems equipped with contemporary hardware can provide high-quality structural lung imaging by virtue of the prolonged T2 *. Fortuitously, the T1 relaxivity of oxygen increases at lower field strengths, which is expected to improve the sensitivity of oxygen-enhanced lung MRI. We implemented a breath-held T1 -weighted 3D stack-of-spirals UTE acquisition with a 7 ms spiral-out readout. Measurement repeatability was assessed using five repetitions of oxygen-enhanced lung imaging in healthy volunteers (n = 7). The signal intensity at both normoxia and hyperoxia was strongly dependent on lung tissue density modulated by breath-hold volume during the five repetitions. A voxel-wise correction for lung tissue density improved the repeatability of percent signal enhancement maps (coefficient of variation = 34 ± 16%). Percent signal enhancement maps were compared in 15 healthy volunteers and 10 patients with lymphangioleiomyomatosis (LAM), a rare cystic disease known to reduce pulmonary function. We measured a mean percent signal enhancement of 9.0 ± 3.5% at 0.55 T in healthy volunteers, and reduced signal enhancement in patients with LAM (5.4 ± 4.8%, p = 0.02). The heterogeneity, estimated by the percent of lung volume exhibiting low enhancement, was significantly increased in patients with LAM compared with healthy volunteers (11.1 ± 6.0% versus 30.5 ± 13.1%, p = 0.01), illustrating the capability to measure regional functional deficits.
Collapse
Affiliation(s)
- Ipshita Bhattacharya
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Marcus Y Chen
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Thomas Benkert
- Siemens Healthcare GmbH, Henkestraße 127, 91052 Erlangen, Germany
| | - Waqas Majeed
- Siemens Medical Solutions USA Inc., 40 Liberty Boulevard, Malvern PA, 1935 USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Joel Moss
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Robert S Balaban
- Systems Biology Center, Division of Intramural Research, National Heart, Lung, and Blood I nstitute, National Institutes of Health, Bethesda MD, USA 20892
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| |
Collapse
|
22
|
Comparison of Functional Free-Breathing Pulmonary 1H and Hyperpolarized 129Xe Magnetic Resonance Imaging in Pediatric Cystic Fibrosis. Acad Radiol 2021; 28:e209-e218. [PMID: 32532639 DOI: 10.1016/j.acra.2020.05.008] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 05/04/2020] [Accepted: 05/06/2020] [Indexed: 12/19/2022]
Abstract
RATIONALE AND OBJECTIVES Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is a free-breathing 1H-based technique that produces maps of fractional ventilation (FV). This study compared ventilation defect percent (VDP) calculated using PREFUL to hyperpolarized (HP) 129Xe MRI and pulmonary function tests in pediatric cystic fibrosis (CF). MATERIALS AND METHODS 27 pediatric participants were recruited (mean age 13.0 ± 2.7), including 6 with clinically stable CF, 11 CF patients undergoing a pulmonary exacerbation (PEx), and 10 healthy controls. Spirometry was performed to measure forced expiratory volume in 1 second (FEV1), along with nitrogen multiple breath washout to measure lung clearance index (LCI). VDP was calculated from single central coronal slice PREFUL FV maps and the corresponding HP 129Xe slice. RESULTS The stable CF group had a normal FEV1 (p = 0.41) and elevated LCI (p = 0.007). The CF PEx group had a decreased FEV1 (p < 0.0001) and elevated LCI (p < 0.0001). PREFUL and HP 129Xe VDP were significantly different between the CF PEx and healthy groups (p < 0.05). In the stable CF group, PREFUL and HP 129Xe VDP were not significantly different from the healthy group (p = 0.18 and 0.08, respectively). There was a correlation between PREFUL and HP 129Xe VDP (R2 = 0.31, p = 0.004), and both parameters were significantly correlated with FEV1 and LCI. CONCLUSION PREFUL MRI is feasible in pediatric CF, distinguishes patients undergoing pulmonary exacerbations compared to healthy subjects, and correlates with HP 129Xe MRI as well as functional measures of disease severity. PREFUL MRI does not require breath-holds and is straight forward to implement on any MRI scanner.
Collapse
|
23
|
Grynko V, Shepelytskyi Y, Li T, Hassan A, Granberg K, Albert MS. Hyperpolarized 129 Xe multi-slice imaging of the human brain using a 3D gradient echo pulse sequence. Magn Reson Med 2021; 86:3175-3181. [PMID: 34272774 DOI: 10.1002/mrm.28932] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 06/10/2021] [Accepted: 06/30/2021] [Indexed: 12/14/2022]
Abstract
PURPOSE To demonstrate the possibility of performing multi-slice in-vivo human brain MRI using hyperpolarized (HP) xenon-129 (129 Xe) in two different orientations and to calculate the signal-to-noise ratio (SNR). METHODS Two healthy female participants were imaged during a single breath-hold of HP 129 Xe using a Philips Achieva 3.0T MRI scanner (Philips, Andover, MA). Each HP 129 Xe multi-slice brain image was acquired during separate HP 129 Xe breath-holds using 3D gradient echo (GRE) imaging. The acquisition started 10 s after the inhalation of 1 L of HP 129 Xe. Overall, four sagittal and three axial images were acquired (seven imaging sessions per participant). The SNR was calculated for each slice in both orientations. RESULTS The first ever HP 129 Xe multi-slice images of the brain were acquired in axial and sagittal orientations. The HP 129 Xe signal distribution correlated well with the gray matter distribution. The highest SNR values were close in the axial and sagittal orientations (19.46 ± 3.25 and 18.76 ± 4.94, respectively). Additionally, anatomical features, such as the ventricles, were observed in both orientations. CONCLUSION The possibility of using multi-slice HP 129 Xe human brain magnetic resonance imaging was demonstrated for the first time. HP 129 Xe multi-slice MRI can be implemented for brain imaging to improve current diagnostic methods.
Collapse
Affiliation(s)
- Vira Grynko
- Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Yurii Shepelytskyi
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Tao Li
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Ayman Hassan
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| | - Karl Granberg
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada
| | - Mitchell S Albert
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| |
Collapse
|
24
|
Liu H, Zheng L, Shi G, Xu Q, Wang Q, Zhu H, Feng H, Wang L, Zhang N, Xue M, Dai Y. Pulmonary Functional Imaging for Lung Adenocarcinoma: Combined MRI Assessment Based on IVIM-DWI and OE-UTE-MRI. Front Oncol 2021; 11:677942. [PMID: 34307146 PMCID: PMC8292137 DOI: 10.3389/fonc.2021.677942] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 06/11/2021] [Indexed: 01/11/2023] Open
Abstract
Purpose The goal of current study was to introduce noninvasive and reproducible MRI methods for in vivo functional assessment of lung adenocarcinoma (LUAD). Methods Forty-four patients with pathologically confirmed LUAD were included in this study. All the lesions were classified as adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IA). The IA lesions were further divided into five subtype patterns, including acinar, lepidic, papillary, micropapillary and solid. Tumors were grouped depending on predominant subtype: low grade (AIS, MIA or lepidic predominant), intermediate grade (papillary or acinar predominant) and high grade (micropapillary, or solid predominant). Spirometry was performed according to American Thoracic Society guidelines. For each patient, Intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) analysis and oxygen-enhanced MRI (OE-MRI) analysis were performed. Spearman's test was used to assess the relationship between a) whole lung mean percent signal enhancement (PSE) and pulmonary function tests (PFTs) parameters; b) IVIM-derived parameters and PFTs parameters; c) tumor mean PSE and IVIM-derived parameters. Kruskal -Wallis tests were applied to test the difference of tumor mean PSE and IVIM-derived parameters between different histological tumor grades. Receiver operating characteristics (ROC) analysis was used to evaluate the diagnostic performance. Results Whole lung mean PSE was significantly positively correlated with PFTs parameters (r = 0.40 ~ 0.44, P < 0.05). f value derived from IVIM-DWI was significantly negatively correlated with PFTs parameters (r = -0.38 ~ -0.47, P < 0.05). Both tumor mean PSE (P = 0.030 < 0.05) and f (P = 0.022 < 0.05) could differentiate different histological grades. f was negatively correlated with tumor mean PSE (r = -0.61, P < 0.001). For the diagnostic performance, the combination of tumor mean PSE and f outperformed than using tumor mean PSE or f alone in both sensitivity and area under the ROC curve. Conclusions The combined measurement of OE-MRI and IVIM-DWI may serve as a promising method for the noninvasive and non-radiation evaluation of pulmonary function. Quantitative analyses achieved by OE-MRI and IVIM-DWI offer an approach of the classification of LUAD subtypes.
Collapse
Affiliation(s)
- Hui Liu
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Liyun Zheng
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Gaofeng Shi
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Qian Xu
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Qi Wang
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Hongshan Zhu
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Hui Feng
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Lijia Wang
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Ning Zhang
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Meng Xue
- Department of Radiology, Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Yongming Dai
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| |
Collapse
|
25
|
Brooke JP, Hall IP. Novel Thoracic MRI Approaches for the Assessment of Pulmonary Physiology and Inflammation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1304:123-145. [PMID: 34019267 DOI: 10.1007/978-3-030-68748-9_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Excessive pulmonary inflammation can lead to damage of lung tissue, airway remodelling and established structural lung disease. Novel therapeutics that specifically target inflammatory pathways are becoming increasingly common in clinical practice, but there is yet to be a similar stepwise change in pulmonary diagnostic tools. A variety of thoracic magnetic resonance imaging (MRI) tools are currently in development, which may soon fulfil this emerging clinical need for highly sensitive assessments of lung structure and function. Given conventional MRI techniques are poorly suited to lung imaging, alternate strategies have been developed, including the use of inhaled contrast agents, intravenous contrast and specialized lung MR sequences. In this chapter, we discuss technical challenges of performing MRI of the lungs and how they may be overcome. Key thoracic MRI modalities are reviewed, namely, hyperpolarized noble gas MRI, oxygen-enhanced MRI (OE-MRI), ultrashort echo time (UTE) MRI and dynamic contrast-enhanced (DCE) MRI. Finally, we consider potential clinical applications of these techniques including phenotyping of lung disease, evaluation of novel pulmonary therapeutic efficacy and longitudinal assessment of specific patient groups.
Collapse
Affiliation(s)
- Jonathan P Brooke
- Department of Respiratory Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK.
| | - Ian P Hall
- Department of Respiratory Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK.
| |
Collapse
|
26
|
Tanaka Y, Ohno Y, Hanamatsu S, Obama Y, Ueda T, Ikeda H, Iwase A, Fukuba T, Hattori H, Murayama K, Yoshikawa T, Takenaka D, Koyama H, Toyama H. State-of-the-art MR Imaging for Thoracic Diseases. Magn Reson Med Sci 2021; 21:212-234. [PMID: 33952785 PMCID: PMC9199970 DOI: 10.2463/mrms.rev.2020-0184] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Since thoracic MR imaging was first used in a clinical setting, it has been suggested that MR imaging has limited clinical utility for thoracic diseases, especially lung diseases, in comparison with x-ray CT and positron emission tomography (PET)/CT. However, in many countries and states and for specific indications, MR imaging has recently become practicable. In addition, recently developed pulmonary MR imaging with ultra-short TE (UTE) and zero TE (ZTE) has enhanced the utility of MR imaging for thoracic diseases in routine clinical practice. Furthermore, MR imaging has been introduced as being capable of assessing pulmonary function. It should be borne in mind, however, that these applications have so far been academically and clinically used only for healthy volunteers, but not for patients with various pulmonary diseases in Japan or other countries. In 2020, the Fleischner Society published a new report, which provides consensus expert opinions regarding appropriate clinical indications of pulmonary MR imaging for not only oncologic but also pulmonary diseases. This review article presents a brief history of MR imaging for thoracic diseases regarding its technical aspects and major clinical indications in Japan 1) in terms of what is currently available, 2) promising but requiring further validation or evaluation, and 3) developments warranting research investigations in preclinical or patient studies. State-of-the-art MR imaging can non-invasively visualize lung structural and functional abnormalities without ionizing radiation and thus provide an alternative to CT. MR imaging is considered as a tool for providing unique information. Moreover, prospective, randomized, and multi-center trials should be conducted to directly compare MR imaging with conventional methods to determine whether the former has equal or superior clinical relevance. The results of these trials together with continued improvements are expected to update or modify recommendations for the use of MRI in near future.
Collapse
Affiliation(s)
- Yumi Tanaka
- Department of Radiology, Fujita Health University School of Medicine
| | - Yoshiharu Ohno
- Department of Radiology, Fujita Health University School of Medicine.,Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine
| | - Satomu Hanamatsu
- Department of Radiology, Fujita Health University School of Medicine
| | - Yuki Obama
- Department of Radiology, Fujita Health University School of Medicine
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University School of Medicine
| | - Hirotaka Ikeda
- Department of Radiology, Fujita Health University School of Medicine
| | - Akiyoshi Iwase
- Department of Radiology, Fujita Health University Hospital
| | - Takashi Fukuba
- Department of Radiology, Fujita Health University Hospital
| | - Hidekazu Hattori
- Department of Radiology, Fujita Health University School of Medicine
| | - Kazuhiro Murayama
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine
| | | | | | | | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine
| |
Collapse
|
27
|
Gefter WB, Lee KS, Schiebler ML, Parraga G, Seo JB, Ohno Y, Hatabu H. Pulmonary Functional Imaging: Part 2-State-of-the-Art Clinical Applications and Opportunities for Improved Patient Care. Radiology 2021; 299:524-538. [PMID: 33847518 DOI: 10.1148/radiol.2021204033] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Pulmonary functional imaging may be defined as the regional quantification of lung function by using primarily CT, MRI, and nuclear medicine techniques. The distribution of pulmonary physiologic parameters, including ventilation, perfusion, gas exchange, and biomechanics, can be noninvasively mapped and measured throughout the lungs. This information is not accessible by using conventional pulmonary function tests, which measure total lung function without viewing the regional distribution. The latter is important because of the heterogeneous distribution of virtually all lung disorders. Moreover, techniques such as hyperpolarized xenon 129 and helium 3 MRI can probe lung physiologic structure and microstructure at the level of the alveolar-air and alveolar-red blood cell interface, which is well beyond the spatial resolution of other clinical methods. The opportunities, challenges, and current stage of clinical deployment of pulmonary functional imaging are reviewed, including applications to chronic obstructive pulmonary disease, asthma, interstitial lung disease, pulmonary embolism, and pulmonary hypertension. Among the challenges to the deployment of pulmonary functional imaging in routine clinical practice are the need for further validation, establishment of normal values, standardization of imaging acquisition and analysis, and evidence of patient outcomes benefit. When these challenges are addressed, it is anticipated that pulmonary functional imaging will have an expanding role in the evaluation and management of patients with lung disease.
Collapse
Affiliation(s)
- Warren B Gefter
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Kyung Soo Lee
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Mark L Schiebler
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Grace Parraga
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Joon Beom Seo
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Yoshiharu Ohno
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Hiroto Hatabu
- From the Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, South Korea (K.S.L.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (M.L.S.); Departments of Medicine and Medical Biophysics, Robarts Research Institute, Western University, London, Canada (G.P.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Radiology and Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan (Y.O.); and Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| |
Collapse
|
28
|
Mondéjar-López P, Horsley A, Ratjen F, Bertolo S, de Vicente H, Asensio de la Cruz Ò. A multimodal approach to detect and monitor early lung disease in cystic fibrosis. Expert Rev Respir Med 2021; 15:761-772. [PMID: 33843417 DOI: 10.1080/17476348.2021.1908131] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Introduction: In the early stages, lung involvement in cystic fibrosis (CF) can be silent, with disease progression occurring in the absence of clinical symptoms. Irreversible airway damage is present in the early stages of disease; however, reliable biomarkers of early damage due to inflammation and infection that are universally applicable in day-to-day patient management have yet to be identified.Areas covered: At present, the main methods of detecting and monitoring early lung disease in CF are the lung clearance index (LCI), computed tomography (CT), and magnetic resonance imaging (MRI). LCI can be used to detect patients who may require more intense monitoring, identify exacerbations, and monitor responses to new interventions. High-resolution CT detects structural alterations in the lungs of CF patients with the best resolution of current imaging techniques. MRI is a radiation-free imaging alternative that provides both morphological and functional information. The role of MRI for short-term follow-up and pulmonary exacerbations is currently being investigated.Expert opinion: The roles of LCI and MRI are expected to expand considerably over the next few years. Meanwhile, closer collaboration between pulmonology and radiology specialties is an important goal toward improving care and optimizing outcomes in young patients with CF.
Collapse
Affiliation(s)
- Pedro Mondéjar-López
- Pediatric Pulmonologist, Pediatric Pulmonology and Cystic Fibrosis Unit, University Hospital Virgen de la Arrixaca, Murcia, Spain
| | - Alexander Horsley
- Honorary Consultant, Respiratory Research Group, Division of Infection, Immunity & Respiratory Medicine, University of Manchester, Manchester, UK
| | - Felix Ratjen
- Head, Division of Respiratory Medicine, Department of Pediatrics, Translational Medicine, Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Silvia Bertolo
- Radiologist, Department of Radiology, Ca'Foncello Regional Hospital, Treviso, Italy
| | | | - Òscar Asensio de la Cruz
- Pediatric Pulmonologist, Pediatric Unit, University Hospital Parc Taulí de Sabadell, Sabadell, Spain
| |
Collapse
|
29
|
Ohno Y, Seo JB, Parraga G, Lee KS, Gefter WB, Fain SB, Schiebler ML, Hatabu H. Pulmonary Functional Imaging: Part 1-State-of-the-Art Technical and Physiologic Underpinnings. Radiology 2021; 299:508-523. [PMID: 33825513 DOI: 10.1148/radiol.2021203711] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Over the past few decades, pulmonary imaging technologies have advanced from chest radiography and nuclear medicine methods to high-spatial-resolution or low-dose chest CT and MRI. It is currently possible to identify and measure pulmonary pathologic changes before these are obvious even to patients or depicted on conventional morphologic images. Here, key technological advances are described, including multiparametric CT image processing methods, inhaled hyperpolarized and fluorinated gas MRI, and four-dimensional free-breathing CT and MRI methods to measure regional ventilation, perfusion, gas exchange, and biomechanics. The basic anatomic and physiologic underpinnings of these pulmonary functional imaging techniques are explained. In addition, advances in image analysis and computational and artificial intelligence (machine learning) methods pertinent to functional lung imaging are discussed. The clinical applications of pulmonary functional imaging, including both the opportunities and challenges for clinical translation and deployment, will be discussed in part 2 of this review. Given the technical advances in these sophisticated imaging methods and the wealth of information they can provide, it is anticipated that pulmonary functional imaging will be increasingly used in the care of patients with lung disease. © RSNA, 2021 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Joon Beom Seo
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Grace Parraga
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Kyung Soo Lee
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Warren B Gefter
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Sean B Fain
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Mark L Schiebler
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Hiroto Hatabu
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| |
Collapse
|
30
|
Ohno Y, Hanamatsu S, Obama Y, Ueda T, Ikeda H, Hattori H, Murayama K, Toyama H. Overview of MRI for pulmonary functional imaging. Br J Radiol 2021; 95:20201053. [PMID: 33529053 DOI: 10.1259/bjr.20201053] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Morphological evaluation of the lung is important in the clinical evaluation of pulmonary diseases. However, the disease process, especially in its early phases, may primarily result in changes in pulmonary function without changing the pulmonary structure. In such cases, the traditional imaging approaches to pulmonary morphology may not provide sufficient insight into the underlying pathophysiology. Pulmonary imaging community has therefore tried to assess pulmonary diseases and functions utilizing not only nuclear medicine, but also CT and MR imaging with various technical approaches. In this review, we overview state-of-the art MR methods and the future direction of: (1) ventilation imaging, (2) perfusion imaging and (3) biomechanical evaluation for pulmonary functional imaging.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan.,Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Satomu Hanamatsu
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Yuki Obama
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Hirotaka Ikeda
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Hidekazu Hattori
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Kazuhiro Murayama
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| |
Collapse
|
31
|
Ohno Y, Fujisawa Y, Yoshikawa T, Takenaka D, Koyama H, Hattori H, Murayama K, Fujii K, Sugihara N, Toyama H. Inspiratory/expiratory xenon-enhanced area-detector CT: Capability for quantitative assessment of lung ventilation changes in surgically treated non-small cell lung cancer patients. Eur J Radiol 2021; 136:109574. [PMID: 33548852 DOI: 10.1016/j.ejrad.2021.109574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 01/22/2021] [Accepted: 01/24/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE To evaluate the capability of inspiratory/expiratory Xe-enhanced ADCT for assessment of changes in pulmonary function and regional ventilation of surgically treated NSCLC patients. METHOD AND MATERIALS Forty consecutive surgically treated NSCLC patients underwent pre- and postoperative inspiratory/expiratory Xe-enhanced ADCT and pulmonary function tests. For each patient, pre- and post-operative data were analyzed and pre- and post-operative wash-in (WI) and wash-out (WO) indexes and ventilation ratio (VR=[WI-WO]/WI) maps generated by means of pixel-by-pixel analyses. Differences between pre- and postoperative WI (ΔWI), WO (ΔWO) and VR (ΔVR) were also determined. To determine the relationship between all ventilation index changes and pulmonary functional loss, Pearson's correlation was used to correlate each ventilation index change with the corresponding pulmonary functional parameter change. In addition, stepwise regression analysis was performed for all ventilation index changes and each corresponding pulmonary functional parameter change. RESULTS FEV1/FVC% change showed fair or good and significant correlations with ΔWI (r = 0.39, p = 0.01) and ΔVR (r = 0.68, p = 0.001), %FEV1 change good or moderate and significant correlations with ΔWI (r = 0.56, p = 0.0001) and ΔVR (r = 0.76, p < 0.0001), and %VC change moderate yet significant correlation with ΔWI (r = 0.65, p < 0.0001) and ΔVR (r = 0.67, p < 0.0001). Stepwise regression analysis demonstrated that FEV1/FVC% change (r2 = 0.56, p < 0.0001) significantly affected two factors, ΔVR (p < 0.0001) and ΔWI (p = 0.006), as did %FEV1 change (r2 = 0.68, p < 0.0001) [ΔVR (p < 0.0001) and ΔWI (p = 0.0001)], and %VC change (r2 = 0.63, p < 0.0001) [ΔVR (p < 0.0001) and ΔWI (p = 0.0001)]. CONCLUSION Inspiratory/expiratory Xe-enhanced ADCT has the potential to demonstrate that pre- and postoperative ventilation status of surgically treated NSCLC patients correlates with pulmonary function.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan; Joint Laboratory Research of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan; Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
| | | | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan; Department of Radiology, Hyogo Cancer Center, Akashi, Japan
| | | | - Hisanobu Koyama
- Department of Radiology, Osaka Police Hospital, Osaka, Japan
| | - Hidetkazu Hattori
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Kazuhiro Murayama
- Joint Laboratory Research of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Kenji Fujii
- Canon Medical Systems Corporation, Otawara, Japan
| | | | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| |
Collapse
|
32
|
Kaireit TF, Kern A, Voskrebenzev A, Pöhler GH, Klimes F, Behrendt L, Gutberlet M, Moher-Alsady T, Dittrich AM, Wacker F, Hohlfeld J, Vogel-Claussen J. Flow Volume Loop and Regional Ventilation Assessment Using Phase-Resolved Functional Lung (PREFUL) MRI: Comparison With 129 Xenon Ventilation MRI and Lung Function Testing. J Magn Reson Imaging 2020; 53:1092-1105. [PMID: 33247456 DOI: 10.1002/jmri.27452] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 11/09/2020] [Accepted: 11/12/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Regional flow volume loop ventilation-weighted noncontrast-enhanced proton lung MRI in free breathing has emerged as a novel technique for assessment of regional lung ventilation, but has yet not been validated with 129 Xenon MRI (129 Xe-MRI), a direct visualization of ventilation in healthy volunteers, cystic fibrosis (CF), and chronic obstructive pulmonary disease (COPD) patients. PURPOSE To compare regional ventilation and regional flow volume loops measured by noncontrast-enhanced ventilation-weighted phase-resolved functional lung MRI (PREFUL-MRI) with 129 Xe-MRI ventilation imaging and with lung function test parameters. STUDY TYPE Retrospective study. POPULATION Twenty patients with COPD, eight patients with CF, and six healthy volunteers. FIELD STRENGTH/SEQUENCE PREFUL and 129 Xe-MRI gradient echo sequences were acquired at 1.5T. ASSESSMENT Coronal slices of PREFUL-MRI (free breathing) and 129 Xe-MRI (single breath-hold) were acquired on the same day, matched by their ventrodorsal position and coregistered for evaluation. Ventilation defect percentage (VDP) was calculated based on regional ventilation (RV), regional flow volume loops (RFVL), or 129 Xe-MRI with two different threshold methods. A combined VDP was calculated for RV and RFVL. Additionally, lung function testing was performed (such as the forced expiratory volume in 1 second [FEV1 ]) was used. STATISTICAL TESTS The obtained parameters were compared using Wilcoxon tests, correlated using Spearman's correlation coefficient (r), and agreement between PREFUL and 129 Xe-MRI parameters was assessed using Bland-Altman analysis and Dice coefficients. RESULTS VDP measured by PREFUL and 129 Xe were significantly correlated with both thresholding techniques (r = 0.62-0.69, P < 0.05 for all) and with lung function test parameters. Combined RV and RFVL PREFUL defect maps correlated with lung function testing (eg, with FEV1 r = -0.87 P < 0.05), and showed better regional agreement to 129 Xe-MRI ventilation defects (Dice coefficient defect 0.413) with significantly higher VDP values (10.2 ± 27.3, P = 0.04) than either PREFUL defect map alone. DATA CONCLUSION Combined RV and RFVL PREFUL defect maps likely increase sensitivity to mild airway obstruction with increased VDP values compared to 129 Xe-MRI, and correlate strongly with lung function test parameters. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Till F Kaireit
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Agilo Kern
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Andreas Voskrebenzev
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Gesa H Pöhler
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Filip Klimes
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Lea Behrendt
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Marcel Gutberlet
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Tawfik Moher-Alsady
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Anna-Maria Dittrich
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany.,Department for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Frank Wacker
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| | - Jens Hohlfeld
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany.,Clinic of Pneumology, Hannover Medical School, Hannover, Germany.,Fraunhofer Institute for T oxicology and Experimental Medicine, Hannover, Germany
| | - Jens Vogel-Claussen
- Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.,Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Lung Research Center (DZL), Hannover, Germany
| |
Collapse
|
33
|
Ohno Y, Yui M, Yoshikawa T, Seki S, Takenaka D, Kassai Y, Hattori H, Murayama K, Toyama H. 3D Oxygen-Enhanced MRI at 3T MR System: Comparison With Thin-Section CT of Quantitative Capability for Pulmonary Functional Loss Assessment and Clinical Stage Classification of COPD in Smokers. J Magn Reson Imaging 2020; 53:1042-1051. [PMID: 33205499 DOI: 10.1002/jmri.27441] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/25/2020] [Accepted: 10/27/2020] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Oxygen (O2 )-enhanced MRI is mainly performed by a 2D sequence using 1.5T MR systems but trying to be obtained by a 3D sequence using a 3T MR system. PURPOSE To compare the capability of 3D O2 -enhanced MRI and that of thin-section computed tomography (CT) for pulmonary functional loss assessment and clinical stage classification of chronic obstructive pulmonary disease (COPD) in smokers. STUDY TYPE Prospective study. POPULATION Fifty six smokers were included. FIELD STRENGTH/ SEQUENCE 3T, 3D O2 -enhanced MRIs were performed with a 3D T1 -weighted fast field echo pulse sequence using the multiple flip angles. ASSESSMENTS Smokers were classified into four stages ("Without COPD," "Mild COPD," "Moderate COPD," "Severe or very severe COPD"). Maps of regional changes in T1 values were generated from O2 -enhanced MR data. Regions of interest (ROIs) were then placed over the lung on all slices and averaged to determine mean T1 value change (ΔT1 ). Quantitative CT used the percentage of low attenuation areas within the entire lung (LAA%). STATISTICAL TESTS ΔT1 and LAA% were correlated with pulmonary functional parameters, and compared for four stages using Tukey's Honestly Significant Difference test. Discrimination analyses were performed and McNemar's test was used for a comparison of the accuracy of the indexes. RESULTS There were significantly higher correlations between ΔT1 and pulmonary functional parameters (-0.83 ≤ r ≤ -0.71, P < 0.05) than between LAA% and the same pulmonary functional parameters (-0.76 ≤ r ≤ -0.69, P < 0.05). ΔT1 and LAA% of the "Mild COPD" and "Moderate COPD" groups were significantly different from those of the "Severe or Very Severe COPD" group (P < 0.05). Discriminatory accuracy of ΔT1 (62.5%) and ΔT1 with LAA% (67.9%) was significantly greater than that of LAA% (48.2%, P < 0.05). DATA CONCLUSION Compared with thin-section CT, 3D O2 -enhanced MRI has a similar capability for pulmonary functional assessment but better potential for clinical stage classification in smokers. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan.,Joint Laboratory Research of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan.,Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Masao Yui
- Canon Medical Systems Corporation, Otawara, Japan
| | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.,Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan
| | - Shinichiro Seki
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Daisuke Takenaka
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan
| | | | - Hidekazu Hattori
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Kazuhiro Murayama
- Joint Laboratory Research of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| |
Collapse
|
34
|
Pöhler GH, Klimeš F, Behrendt L, Voskrebenzev A, Gonzalez CC, Wacker F, Hohlfeld JM, Vogel‐Claussen J. Repeatability of Phase‐Resolved Functional Lung (
PREFUL
)‐
MRI
Ventilation and Perfusion Parameters in Healthy Subjects and
COPD
Patients. J Magn Reson Imaging 2020; 53:915-927. [DOI: 10.1002/jmri.27385] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 09/14/2020] [Accepted: 09/17/2020] [Indexed: 12/21/2022] Open
Affiliation(s)
- Gesa H. Pöhler
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| | - Filip Klimeš
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| | - Lea Behrendt
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| | - Andreas Voskrebenzev
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| | - Cristian Crisosto Gonzalez
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| | - Frank Wacker
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| | - Jens M. Hohlfeld
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
- Department of Respiratory Medicine Hannover Medical School Hannover Germany
- Fraunhofer Institute of Toxicology and Experimental Medicine Hannover Germany
| | - Jens Vogel‐Claussen
- Institute for Diagnostic and Interventional Radiology Hannover Medical School Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL) Hannover Germany
| |
Collapse
|
35
|
Maunder A, Chan HF, Hughes PJC, Collier G, Norquay G, Rodgers O, Thelwall P, Robb F, Rao M, Wild JM. MR properties of 19 F C 3 F 8 gas in the lungs of healthy volunteers: T 2 ∗ and apparent diffusion coefficient at 1.5T and T 2 ∗ at 3T. Magn Reson Med 2020; 85:1561-1570. [PMID: 32926448 DOI: 10.1002/mrm.28511] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 08/08/2020] [Accepted: 08/17/2020] [Indexed: 01/07/2023]
Abstract
PURPOSE To measure the transverse relaxation time ( T 2 ∗ ) and apparent diffusion coefficient (ADC) of 19 F-C3 F8 gas in vivo in human lungs at 1.5T and 3T, and to determine the representative distribution of values of these parameters in a cohort of healthy volunteers. METHODS Mapping of ADC at lung inflation levels of functional residual capacity (FRC) and total lung capacity (TLC) was performed with inhaled 19 F-C3 F8 (eight subjects) and 129 Xe (six subjects) at 1.5T. T 2 ∗ mapping with 19 F-C3 F8 was performed at 1.5T (at FRC and TLC) for 8 subjects and at 3T (at TLC for seven subjects). RESULTS At both FRC and TLC, the 19 F-C3 F8 ADC was smaller than the free diffusion coefficient demonstrating airway microstructural diffusion restriction. From FRC to TLC, the mean ADC significantly increased from 1.56 mm2 /s to 1.83 mm2 /s (P = .0017) for 19 F-C3 F8, and from 2.49 mm2 /s to 3.38 mm2 /s (P = .0015) for 129 Xe. The posterior-to-anterior gradient in ADC for FRC versus TLC in the superior half of the lungs was measured as 0.0308 mm2 /s per cm versus 0.0168 mm2 /s per cm for 19 F-C3 F8 and 0.0871 mm2 /s per cm versus 0.0326 mm2 /s per cm for 129 Xe. A consistent distribution of 19 F-C3 F8 T 2 ∗ values was observed in the lungs, with low values observed near the diaphragm and large pulmonary vessels. The mean T 2 ∗ across volunteers was 4.48 ms at FRC and 5.33 ms at TLC for 1.5T, and 3.78 ms at TLC for 3T. CONCLUSION In this feasibility study, values of physiologically relevant parameters of lung microstructure measurable by MRI ( T 2 ∗ , and ADC) were established for C3 F8 in vivo lung imaging in healthy volunteers.
Collapse
Affiliation(s)
- Adam Maunder
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Ho-Fung Chan
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Paul J C Hughes
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Guillhem Collier
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Graham Norquay
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Oliver Rodgers
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Peter Thelwall
- Newcastle Magnetic Resonance Centre, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Fraser Robb
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom.,GE Healthcare, Aurora, Ohio, USA
| | - Madhwesha Rao
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Jim M Wild
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
36
|
Sim AJ, Kaza E, Singer L, Rosenberg SA. A review of the role of MRI in diagnosis and treatment of early stage lung cancer. Clin Transl Radiat Oncol 2020; 24:16-22. [PMID: 32596518 PMCID: PMC7306507 DOI: 10.1016/j.ctro.2020.06.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 05/25/2020] [Accepted: 06/01/2020] [Indexed: 12/14/2022] Open
Abstract
Despite magnetic resonance imaging (MRI) being a mainstay in the oncologic care for many disease sites, it has not routinely been used in early lung cancer diagnosis, staging, and treatment. While MRI provides improved soft tissue contrast compared to computed tomography (CT), an advantage in multiple organs, the physical properties of the lungs and mediastinum create unique challenges for lung MRI. Although multi-detector CT remains the gold standard for lung imaging, advances in MRI technology have led to its increased clinical relevance in evaluating early stage lung cancer. Even though positron emission tomography is used more frequently in this context, functional MR imaging, including diffusion-weighted MRI and dynamic contrast-enhanced MRI, are emerging as useful modalities for both diagnosis and evaluation of treatment response for lung cancer. In parallel with these advances, the development of combined MRI and linear accelerator devices (MR-linacs), has spurred the integration of MRI into radiation treatment delivery in the form of MR-guided radiotherapy (MRgRT). Despite challenges for MRgRT in early stage lung cancer radiotherapy, early data utilizing MR-linacs shows potential for the treatment of early lung cancer. In both diagnosis and treatment, MRI is a promising modality for imaging early lung cancer.
Collapse
Affiliation(s)
- Austin J. Sim
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 USF Magnolia Dr., Tampa, FL, USA
| | - Evangelia Kaza
- Department of Radiation Oncology, Dana Farber Cancer Institute, Brigham & Women’s Hospital & Harvard Medical School, 75 Francis St., Boston, MA, USA
| | - Lisa Singer
- Department of Radiation Oncology, Dana Farber Cancer Institute, Brigham & Women’s Hospital & Harvard Medical School, 75 Francis St., Boston, MA, USA
| | - Stephen A. Rosenberg
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 USF Magnolia Dr., Tampa, FL, USA
- University of South Florida Morsani College of Medicine, 12901 Bruce B. Downs Blvd., Tampa, FL, USA
| |
Collapse
|
37
|
Hyperpolarized 129Xe Time-of-Flight MR Imaging of Perfusion and Brain Function. Diagnostics (Basel) 2020; 10:diagnostics10090630. [PMID: 32854196 PMCID: PMC7554935 DOI: 10.3390/diagnostics10090630] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 08/22/2020] [Accepted: 08/23/2020] [Indexed: 02/07/2023] Open
Abstract
Perfusion measurements can provide vital information about the homeostasis of an organ and can therefore be used as biomarkers to diagnose a variety of cardiovascular, renal, and neurological diseases. Currently, the most common techniques to measure perfusion are 15O positron emission tomography (PET), xenon-enhanced computed tomography (CT), single photon emission computed tomography (SPECT), dynamic contrast enhanced (DCE) MRI, and arterial spin labeling (ASL) MRI. Here, we show how regional perfusion can be quantitively measured with magnetic resonance imaging (MRI) using time-resolved depolarization of hyperpolarized (HP) xenon-129 (129Xe), and the application of this approach to detect changes in cerebral blood flow (CBF) due to a hemodynamic response in response to brain stimuli. The investigated HP 129Xe Time-of-Flight (TOF) technique produced perfusion images with an average signal-to-noise ratio (SNR) of 10.35. Furthermore, to our knowledge, the first hemodynamic response (HDR) map was acquired in healthy volunteers using the HP 129Xe TOF imaging. Responses to visual and motor stimuli were observed. The acquired HP TOF HDR maps correlated well with traditional proton blood oxygenation level-dependent functional MRI. Overall, this study expands the field of HP MRI with a novel dynamic imaging technique suitable for rapid and quantitative perfusion imaging.
Collapse
|
38
|
Shepelytskyi Y, Li T, Grynko V, Newman C, Hane FT, Albert MS. Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model. Magn Reson Med 2020; 85:987-994. [PMID: 32789900 PMCID: PMC7689774 DOI: 10.1002/mrm.28473] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 07/13/2020] [Accepted: 07/21/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-noise ratio (SNR) and PFP SNR predicted the average SNR advantage of 90% using OFCB during gradient echo imaging. The OFCB relaxometry was conducted using single-voxel spectroscopy and spin-echo imaging. A comparison of OFCB and PFP SNRs was performed in vitro and in vivo. Five healthy Sprague-Dawley rats were imaged during single breath-hold and continuous breathing using a Philips Achieva 3.0T MRI scanner (Philips, Andover, MA). The scan time was constant for both gases. Statistical comparison between PFP and OFCB scans was conducted using a paired t test and by calculating the Bayes factor. RESULTS Spin-lattice (T1 ) and effective spin-spin ( T 2 ∗ ) relaxation time constants of the pure OFCB gas were determined as 28.5 ± 1.2 ms and 10.5 ± 1.8 ms, respectively. Mixing with 21% of oxygen decreased T1 by 30% and T 2 ∗ by 20%. The OFCB in vivo images showed 73% higher normalized SNR on average compared with images acquired using PFP. The statistical significance was shown by both paired t test and calculated Bayes factors. The experimental results agree with theoretical calculations within the error of the relaxation parameter measurements. CONCLUSION The quality of the lung images acquired using OFCB was significantly better compared with PFP scans. The OFCB images had higher a SNR and were artifact-free.
Collapse
Affiliation(s)
- Yurii Shepelytskyi
- Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Tao Li
- Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Vira Grynko
- Chemistry and Materials Science Program, Lakehead University, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| | - Camryn Newman
- Biology Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Francis T Hane
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada
| | - Mitchell S Albert
- Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.,Chemistry Department, Lakehead University, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada
| |
Collapse
|
39
|
Wallat EM, Flakus MJ, Wuschner AE, Shao W, Christensen GE, Reinhardt JM, Baschnagel AM, Bayouth JE. Modeling the impact of out‐of‐phase ventilation on normal lung tissue response to radiation dose. Med Phys 2020; 47:3233-3242. [DOI: 10.1002/mp.14146] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 02/14/2020] [Accepted: 03/09/2020] [Indexed: 12/24/2022] Open
Affiliation(s)
- Eric M. Wallat
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - Mattison J. Flakus
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - Antonia E. Wuschner
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - Wei Shao
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA 52242 USA
| | - Gary E. Christensen
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA 52242 USA
| | - Joseph M. Reinhardt
- Department of Biomedical Engineering University of Iowa Iowa City IA 52242 USA
| | - Andrew M. Baschnagel
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - John E. Bayouth
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| |
Collapse
|
40
|
Pavlova OS, Anisimov NV, Gervits LL, Gulyaev MV, Semenova VN, Pirogov YA, Panchenko VY. 19 F MRI of human lungs at 0.5 Tesla using octafluorocyclobutane. Magn Reson Med 2020; 84:2117-2123. [PMID: 32274848 DOI: 10.1002/mrm.28270] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Revised: 03/05/2020] [Accepted: 03/09/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE The aim of this study was to demonstrate the feasibility of fluorine-19 (19 F) MRI of the human lungs using octafluorocyclobutane (OFCB, C4 F8 ). This gas has 8 magnetically equivalent fluorine nuclei and relatively long T1 and T2 (˜50 ms), which render it suitable as an MRI contrast agent. Previous experiments in small laboratory animals showed that OFCB could be successfully used as an alternative to the gases often used for 19 F MRI (sulfur hexafluoride and perfluoropropane). METHODS One male volunteer participated in this study. Immediately before an MRI scan, the volunteer inhaled the gas mixture-80% OFCB with 20% oxygen-and held his breath. Experiments were performed on a 0.5T whole-body MR scanner with a customized transmit-receive coil tuned at 19 F frequency. Fast spin echo in 2D and 3D modes was used for image acquisition. 2D images were obtained with in-plane resolution of 10 × 10 mm2 without slice selection. 3D images were obtained with the voxel size of 10 × 10 × 30 mm2 . Breath-hold duration was 20 s for 2D and 40 s for 3D imaging, respectively. RESULTS Anatomically consistent 19 F MR images of the human lungs were obtained with SNR around 50 in 2D mode and 20 in 3D mode. 3D volumetric images of the lungs were reconstructed and provided physiologically reasonable volume estimates. CONCLUSION The application of OFCB enables informative 19 F lung imaging even at low magnetic field strengths. The OFCB gas shows promise as an inhalable contrast agent for fluorine lung MRI and has a potential for clinical translation.
Collapse
Affiliation(s)
- Olga S Pavlova
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia
| | - Nikolay V Anisimov
- Faculty of Fundamental Medicine, Lomonosov Moscow State University, Moscow, Russia
| | - Lev L Gervits
- Nesmeyanov Institute of Organoelement Compounds of the Russian Academy of Sciences, Moscow, Russia
| | - Mikhail V Gulyaev
- Faculty of Fundamental Medicine, Lomonosov Moscow State University, Moscow, Russia
| | | | - Yury A Pirogov
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia
| | | |
Collapse
|
41
|
Goralski JL, Chung SH, Glass TM, Ceppe AS, Akinnagbe-Zusterzeel EO, Trimble AT, Boucher RC, Soher BJ, Charles HC, Donaldson SH, Lee YZ. Dynamic perfluorinated gas MRI reveals abnormal ventilation despite normal FEV1 in cystic fibrosis. JCI Insight 2020; 5:133400. [PMID: 31855577 DOI: 10.1172/jci.insight.133400] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 12/10/2019] [Indexed: 11/17/2022] Open
Abstract
We hypothesized that dynamic perfluorinated gas MRI would sensitively detect mild cystic fibrosis (CF) lung disease. This cross-sectional study enrolled 20 healthy volunteers and 24 stable subjects with CF, including a subgroup of subjects with normal forced expiratory volume in the first second (FEV1; >80% predicted, n = 9). Dynamic fluorine-19-enhanced MRI (19F MRI) were acquired during sequential breath holds while breathing perfluoropropane (PFP) and during gas wash-out. Outcomes included the fraction of lung without significant ventilation (ventilation defect percent, VDP) and time constants that described PFP wash-in and wash-out kinetics. VDP values (mean ± SD) of healthy controls (3.87% ± 2.7%) were statistically different from moderate CF subjects (19.5% ± 15.5%, P = 0.001) but not from mild CF subjects (10.4% ± 9.9%, P = 0.24). In contrast, the fractional lung volume with slow gas wash-out was elevated both in subjects with mild (9.61% ± 4.87%; P = 0.0066) and moderate CF (16.01% ± 5.01%; P = 0.0002) when compared with healthy controls (3.84% ± 2.16%) and distinguished mild from moderate CF (P = 0.006). 19F MRI detected significant ventilation abnormalities in subjects with CF. The ability of gas wash-out kinetics to distinguish between healthy and mild CF lung disease subjects makes 19F MRI a potentially valuable method for the characterization of early lung disease in CF. This study has been registered at ClinicalTrials.gov (NCT03489590).
Collapse
Affiliation(s)
- Jennifer L Goralski
- Division of Pulmonary Diseases and Critical Care Medicine, Department of Medicine.,Marsico Lung Institute.,Division of Pediatric Pulmonology, Department of Pediatrics
| | | | - Tyler M Glass
- School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Agathe S Ceppe
- Division of Pulmonary Diseases and Critical Care Medicine, Department of Medicine.,Marsico Lung Institute
| | | | - Aaron T Trimble
- Division of Pulmonary Diseases and Critical Care Medicine, Department of Medicine.,Marsico Lung Institute
| | - Richard C Boucher
- Division of Pulmonary Diseases and Critical Care Medicine, Department of Medicine.,Marsico Lung Institute
| | - Brian J Soher
- Center for Advanced Magnetic Resonance Development and
| | - H Cecil Charles
- Duke Image Analysis Laboratory, Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA
| | - Scott H Donaldson
- Division of Pulmonary Diseases and Critical Care Medicine, Department of Medicine.,Marsico Lung Institute
| | - Yueh Z Lee
- Division of Pulmonary Diseases and Critical Care Medicine, Department of Medicine.,Biomedical Research Imaging Center, and
| |
Collapse
|
42
|
Prayle A, Rosenow T. Looking under the bonnet of bronchopulmonary dysplasia with MRI. Thorax 2020; 75:100. [DOI: 10.1136/thoraxjnl-2019-213421] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 12/08/2019] [Accepted: 12/09/2019] [Indexed: 11/04/2022]
|
43
|
Ohno Y, Fujisawa Y, Sugihara N, Kishida Y, Koyama H, Seki S, Yoshikawa T. Wash-in/wash-out phase xenon-enhanced area-detector CT (ADCT): utility for regional ventilation, pulmonary functional loss and clinical stage evaluations of smokers. Acta Radiol 2019; 60:1619-1628. [PMID: 30997827 DOI: 10.1177/0284185119840647] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
- Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan
| | | | | | - Yuji Kishida
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Hisanobu Koyama
- Department of Radiology, Osaka Police Hospital, Osaka, Japan
| | - Shinichiro Seki
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
- Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
- Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|
44
|
Neal MA, Pippard BJ, Simpson AJ, Thelwall PE. Dynamic susceptibility contrast 19 F-MRI of inhaled perfluoropropane: a novel approach to combined pulmonary ventilation and perfusion imaging. Magn Reson Med 2019; 83:452-461. [PMID: 31468589 PMCID: PMC6899496 DOI: 10.1002/mrm.27933] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 07/12/2019] [Accepted: 07/16/2019] [Indexed: 12/19/2022]
Abstract
PURPOSE To assess alveolar perfusion by applying dynamic susceptibility contrast MRI to 19 F-MRI of inhaled perfluoropropane (PFP). We hypothesized that passage of gadolinium-based contrast agent (GBCA) through the pulmonary microvasculature would reduce magnetic susceptibility differences between water and gas components of the lung, elevating the T 2 ∗ of PFP. METHODS Lung-representative phantoms were constructed of aqueous PFP-filled foams to characterize the impact of aqueous/gas phase magnetic susceptibility differences on PFP T 2 ∗ . Aqueous phase magnetic susceptibility was modulated by addition of different concentrations of GBCA. In vivo studies were performed to measure the impact of intravenously administered GBCA on the T 2 ∗ of inhaled PFP in mice (7.0 Tesla) and in healthy volunteers (3.0 Tesla). RESULTS Perfluoropropane T 2 ∗ was sensitive to modulation of magnetic susceptibility difference between gas and water components of the lung, both in phantom models and in vivo. Negation of aqueous/gas phase magnetic susceptibility difference was achieved in lung-representative phantoms and in mice, resulting in a ~2 to 3× elevation in PFP T 2 ∗ (3.7 to 8.5 ms and 0.7 to 2.6 ms, respectively). Human studies demonstrated a transient elevation of inhaled PFP T 2 ∗ (1.50 to 1.64 ms) during passage of GBCA bolus through the lung circulation, demonstrating sensitivity to lung perfusion. CONCLUSION We demonstrate indirect detection of a GBCA in the pulmonary microvasculature via changes to the T 2 ∗ of gas phase PFP within directly adjacent alveoli. This approach holds potential for assessing alveolar perfusion by dynamic susceptibility contrast 19 F-MRI of inhaled PFP, with concurrent assessment of lung ventilation properties, relevant to lung physiology and disease.
Collapse
Affiliation(s)
- Mary A Neal
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, United Kingdom.,Newcastle Magnetic Resonance Centre, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Benjamin J Pippard
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, United Kingdom.,Newcastle Magnetic Resonance Centre, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - A John Simpson
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, United Kingdom.,Respiratory Medicine, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, United Kingdom
| | - Peter E Thelwall
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, United Kingdom.,Newcastle Magnetic Resonance Centre, Newcastle University, Newcastle upon Tyne, United Kingdom
| |
Collapse
|
45
|
Zanette B, Santyr G. Accelerated interleaved spiral-IDEAL imaging of hyperpolarized 129 Xe for parametric gas exchange mapping in humans. Magn Reson Med 2019; 82:1113-1119. [PMID: 30989730 DOI: 10.1002/mrm.27765] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Revised: 01/22/2019] [Accepted: 03/18/2019] [Indexed: 12/24/2022]
Abstract
PURPOSE To demonstrate the feasibility of mapping gas exchange with single breath-hold hyperpolarized (HP) 129 Xe in humans, acquiring parametric maps of lung physiology. The potential benefit of acceleration using parallel imaging for this application is also explored. METHODS Six healthy volunteers were scanned with a modified spiral-IDEAL sequence to acquire gas exchange-weighted images using a single dose of 129 Xe. These images were fit with the model of xenon exchange (MOXE) on a voxel-wise basis calculating parametric maps of lung physiology, specifically: air-capillary barrier thickness (δ), alveolar septal thickness (d), capillary transit time (tx ), pulmonary hematocrit (HCT), and alveolar surface area-to-volume ratio (SVR). An accelerated version of the sequence was also tested in subset of 4 volunteers and compared to the fully sampled (FS) results. RESULTS Mean image-wide values calculated from MOXE parametric maps derived from FS dissolved 129 Xe spiral-IDEAL images were: δ = 0.89 ± 0.17 μm, d = 7.5 ± 0.5 μm, tx = 1.1 ± 0.2s, HCT = 28.8 ± 2.3%, and SVR = 140 ± 16 cm-1 , in good agreement with previously published values based on whole-lung spectroscopy of healthy human subjects. Parallel imaging sufficiently reduces artifacting in accelerated images, but increases disagreement with MOXE parameters derived from FS data with mean voxel-wise unsigned relative differences of: δ = 39 ± 9%, d = 22 ± 3%, tx = 117 ± 43%, HCT = 11 ± 2%, and SVR = 31 ± 12%. CONCLUSION Dissolved HP 129 Xe spiral-IDEAL imaging for gas exchange mapping is feasible in humans using a single breath-hold. Accelerated gas exchange mapping is also shown to be feasible but requires further improvements to increase quantitative accuracy.
Collapse
Affiliation(s)
- Brandon Zanette
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Giles Santyr
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario, Canada
| |
Collapse
|
46
|
Multibreath Hyperpolarized 3He Imaging Scheme to Measure Alveolar Oxygen Tension and Apparent Diffusion Coefficient. Acad Radiol 2019; 26:367-382. [PMID: 30630659 DOI: 10.1016/j.acra.2018.10.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 09/20/2018] [Accepted: 10/01/2018] [Indexed: 12/15/2022]
Abstract
RATIONALE AND OBJECTIVES In this study, we compared a newly developed multibreath simultaneous alveolar oxygen tension and apparent diffusion coefficient (PAO2-ADC) imaging sequence to a single-breath acquisition, with the aim of mitigating the compromising effects of intervoxel flow and slow-filling regions on single-breath measurements, especially in chronic obstructive pulmonary disease (COPD) subjects. MATERIALS AND METHODS Both single-breath and multibreath simultaneous PAO2-ADC imaging schemes were performed on a total of 10 human subjects (five asymptomatic smokers and five COPD subjects). Estimated PAO2 and ADC values derived from the different sequences were compared both globally and regionally. The distribution of voxels with nonphysiological values was also compared between the two schemes. RESULTS The multibreath protocol decreased the ventilation defect volumes by an average of 12.9 ± 6.6%. The multibreath sequence generated nonphysiological PAO2 values in 11.0 ± 8.5% fewer voxels than the single-breath sequence. Single-breath PAO2 maps also showed more regions with gas-flow artifacts and general signal heterogeneity. On average, the standard deviation of the PAO2 distribution was 16.5 ± 7.0% lower using multibreath PAO2-ADC imaging, suggesting a more homogeneous gas distribution. Both mean and standard deviation of the ADC increased significantly from single- to multibreath imaging (p = 0.048 and p = 0.070, respectively), suggesting more emphysematous regions in the slow-filling lung. CONCLUSION Multibreath PAO2-ADC imaging provides superior accuracy and efficiency compared to previous imaging protocols. PAO2 and ADC maps generated by multibreath imaging allowed for the qualification of various regions as emphysematous or obstructed, which single-breath PAO2 maps can only identify as defects. The simultaneous PAO2 and ADC measurements generated by the presented multibreath method were also more physiologically realistic, and allowed for more detailed analysis of the slow-filling regions characteristic of COPD subjects.
Collapse
|
47
|
Torres L, Kammerman J, Hahn AD, Zha W, Nagle SK, Johnson K, Sandbo N, Meyer K, Schiebler M, Fain SB. "Structure-Function Imaging of Lung Disease Using Ultrashort Echo Time MRI". Acad Radiol 2019; 26:431-441. [PMID: 30658930 DOI: 10.1016/j.acra.2018.12.007] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 12/19/2018] [Accepted: 12/21/2018] [Indexed: 12/14/2022]
Abstract
RATIONALE AND OBJECTIVES The purpose of this review is to acquaint the reader with recent advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and its implications for pulmonary MRI when used in conjunction with functional MRI technique. MATERIALS AND METHODS We provide an overview of recent technical advances of UTE and explore the advantages of combined structure-function pulmonary imaging in the context of restrictive and obstructive pulmonary diseases such as idiopathic pulmonary fibrosis (IPF) and cystic fibrosis (CF). RESULTS UTE MRI clearly shows the lung parenchymal changes due to IPF and CF. The use of UTE MRI, in conjunction with established functional lung MRI in chronic lung diseases, will serve to mitigate the need for computed tomography in children. CONCLUSION Current limitations of UTE MRI include long scan times, poor delineation of thin-walled structures (e.g. cysts and reticulation) due to limited spatial resolution, low signal to noise ratio, and imperfect motion compensation. Despite these limitations, UTE MRI can now be considered as an alternative to multidetector computed tomography for the longitudinal follow-up of the morphological changes from lung diseases in neonates, children, and young adults, particularly as a complement to the unique functional capabilities of MRI.
Collapse
|
48
|
Gutberlet M, Kaireit TF, Voskrebenzev A, Kern AL, Obert A, Wacker F, Hohlfeld JM, Vogel-Claussen J. Repeatability of Regional Lung Ventilation Quantification Using Fluorinated ( 19F) Gas Magnetic Resonance Imaging. Acad Radiol 2019; 26:395-403. [PMID: 30472224 DOI: 10.1016/j.acra.2018.10.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 07/03/2018] [Accepted: 10/24/2018] [Indexed: 11/17/2022]
Abstract
RATIONALE AND OBJECTIVES To assess the repeatability of global and regional lung ventilation quantification in both healthy subjects and patients with chronic obstructive pulmonary disease (COPD) using fluorinated (19F) gas washout magnetic resonance (MR) imaging in free breathing. MATERIAL AND METHODS In this prospective institutional review board-approved study, 12 healthy nonsmokers and eight COPD patients were examined with 19F dynamic gas washout MR imaging in free breathing and with lung function testing. Measurements were repeated within 2 weeks. Lung ventilation was quantified using 19F gas washout time. Repeatability was analyzed for the total lung and on a regional basis using the coefficient of variation (COV) and Bland-Altman plots. RESULTS In healthy subjects and COPD patients, a good repeatability was found for lung ventilation quantification using dynamic 19F gas washout MR imaging on a global (COV < 8%) and regional (COV < 15%) level. Gas washout time was significantly increased in the COPD group compared to the healthy subjects. CONCLUSION 19F gas washout MR imaging provides a good repeatability of lung ventilation quantification and appears to be sensitive to early changes of regional lung function alterations such as normal aging.
Collapse
Affiliation(s)
- Marcel Gutberlet
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Till F Kaireit
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Andreas Voskrebenzev
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Agilo L Kern
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Arnd Obert
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Frank Wacker
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Jens M Hohlfeld
- Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany; Clinic of Pneumology, Hannover Medical School, Hannover, Germany; Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany
| | - Jens Vogel-Claussen
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany.
| |
Collapse
|
49
|
A dual 1H/19F birdcage coil for small animals at 7 T MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2019; 32:79-87. [DOI: 10.1007/s10334-018-00733-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 12/14/2018] [Accepted: 12/21/2018] [Indexed: 12/22/2022]
|
50
|
Maunder A, Rao M, Robb F, Wild JM. Optimization of steady-state free precession MRI for lung ventilation imaging with 19 F C 3 F 8 at 1.5T and 3T. Magn Reson Med 2019; 81:1130-1142. [PMID: 30387911 PMCID: PMC6491987 DOI: 10.1002/mrm.27479] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Revised: 06/26/2018] [Accepted: 07/11/2018] [Indexed: 12/12/2022]
Abstract
PURPOSE To optimize 19 F imaging pulse sequences for perfluoropropane (C3 F8 ) gas human lung ventilation MRI considering intrinsic in vivo relaxation parameters at both 1.5T and 3T. METHODS Optimization of the imaging parameters for both 3D spoiled gradient (SPGR) and steady-state free precession (SSFP) 19 F imaging sequences with inhaled 79% C3 F8% and 21% oxygen was performed. Phantom measurements were used to validate simulations of SNR. In vivo parameter mapping and sequence optimization and comparison was performed by imaging the lungs of a healthy adult volunteer. T1 and T2* mapping was performed in vivo to optimize sequence parameters for in vivo lung MRI. The performance of SSFP and SPGR was then evaluated in vivo at 1.5T and 3T. RESULTS The in vivo T2* of C3 F8 was shown to be dependent upon lung inflation level (2.04 ms ± 36% for residual volume and 3.14 ms ± 28% for total lung capacity measured at 3T), with lower T2* observed near the susceptibility interfaces of the diaphragm and around pulmonary blood vessels. Simulation and phantom measurements indicate that a factor of ~2-3 higher SNR can be achieved with SSFP when compared with optimized SPGR. In vivo lung imaging showed a 1.7 factor of improvement in SNR achieved at 1.5T, while the theoretical improvement at 3T was not attained due to experimental SAR constraints, shorter in vivo T1 , and B0 inhomogeneity. CONCLUSION SSFP imaging provides increased SNR in lung ventilation imaging of C3 F8 demonstrated at 1.5T with optimized SSFP similar to the SNR that can be obtained at 3T with optimized SPGR.
Collapse
Affiliation(s)
- Adam Maunder
- POLARIS, Unit of Academic Radiology, Department of IICDUniversity of SheffieldSheffieldUnited Kingdom
| | - Madhwesha Rao
- POLARIS, Unit of Academic Radiology, Department of IICDUniversity of SheffieldSheffieldUnited Kingdom
| | - Fraser Robb
- POLARIS, Unit of Academic Radiology, Department of IICDUniversity of SheffieldSheffieldUnited Kingdom
- GE HealthcareAuroraOhio
| | - Jim M. Wild
- POLARIS, Unit of Academic Radiology, Department of IICDUniversity of SheffieldSheffieldUnited Kingdom
- Insigneo Institute for In silico medicineSheffieldUnited Kingdom
| |
Collapse
|