1
|
Takumi K, Nagano H, Mukai A, Ueda K, Tabata K, Yoshiura T. Cine MR feature tracking analysis for diagnosing thymic epithelial tumors: a feasibility study. Cancer Imaging 2023; 23:42. [PMID: 37127616 PMCID: PMC10150474 DOI: 10.1186/s40644-023-00560-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Accepted: 04/19/2023] [Indexed: 05/03/2023] Open
Abstract
BACKGROUND To assess the feasibility of the cine MR feature tracking technique for the evaluation of cardiovascular-induced morphological deformation in the diagnosis of thymic epithelial tumors (TETs). METHODS Our study population consisted of 43 patients with pathologically proven TETs including 10 low-grade thymomas, 23 high-grade thymomas, and 10 thymic carcinomas. Cine MR images were acquired using a balanced steady-state free precession sequence with short periods of breath-hold in the axial and oblique planes in the slice with the largest lesion cross-sectional area. The tumor margin was manually delineated in the diastolic phase and was automatically tracked for all other cardiac phases. The change rates of the long-to-short diameter ratio (∆LSR) and tumor area (∆area) associated with pulsation were compared between the three pathological groups using the Kruskal-Wallis H test and the Mann-Whitney U test. A receiver-operating characteristic (ROC) curve analysis was performed to assess the ability of each parameter to differentiate thymic carcinomas from thymomas. RESULTS ∆LSR and ∆area were significantly different among the three groups in the axial plane (p = 0.028 and 0.006, respectively) and in the oblique plane (p = 0.034 and 0.043, respectively). ∆LSR and ∆area values were significantly lower in thymic carcinomas than in thymomas in the axial plane (for both, p = 0.012) and in the oblique plane (p = 0.015 and 0.011, respectively). The area under the ROC curves for ∆LSR and ∆area for the diagnosis of thymic carcinoma ranged from 0.755 to 0.764. CONCLUSIONS Evaluation of morphological deformation using cine-MR feature tracking analysis can help diagnose histopathological subtypes of TETs and identify thymic carcinomas preoperatively.
Collapse
Affiliation(s)
- Koji Takumi
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan.
| | - Hiroaki Nagano
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Akie Mukai
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Kazuhiro Ueda
- General Thoracic Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Kazuhiro Tabata
- Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Takashi Yoshiura
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| |
Collapse
|
2
|
Jugé L, Foley P, Hatt A, Yeung J, Bilston LE. Ex vivo bovine liver nonlinear viscoelastic properties: MR elastography and rheological measurements. J Mech Behav Biomed Mater 2023; 138:105638. [PMID: 36623403 DOI: 10.1016/j.jmbbm.2022.105638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 11/28/2022] [Accepted: 12/19/2022] [Indexed: 12/29/2022]
Abstract
INTRODUCTION Knowledge of the nonlinear viscoelastic properties of the liver is important, but the complex tissue behavior outside the linear viscoelastic regime has impeded their characterization, particularly in vivo. Combining static compression with magnetic resonance (MR) elastography has the potential to be a useful imaging method for assessing large deformation mechanical properties of soft tissues in vivo. However, this remains to be verified. Therefore this study aims first to determine whether MR elastography can measure the nonlinear mechanical properties of ex vivo bovine liver tissue under varying levels of uniform and focal preloads (up to 30%), and second to compare MR elastography-derived complex shear modulus with standard rheological measurements. METHOD Nine fresh bovine livers were collected from a local abattoir, and experiments were conducted within 12hr of death. Two cubic samples (∼10 × 10 × 10 cm3) were dissected from each liver and imaged using MR elastography (60 Hz) under 4 levels of uniform and focal preload (1, 10, 20, and 30% of sample width) to investigate the relationship between MR elastography-derived complex shear modulus (G∗) and the maximum principal Right Cauchy Green Strain (C11). Three tissue samples from each of the same 9 livers underwent oscillatory rheometry under the same 4 preloads (1, 10, 20, and 30% strain). MR elastography-derived complex shear modulus (G∗) from the uniform preload was validated against rheometry by fitting the frequency dependence of G∗ with a power-law and extrapolating rheometry-derived G∗ to 60 Hz. RESULTS MR elastography-derived G∗ increased with increasing compressive large deformation strain, and followed a power-law curve (G∗ = 1.73 × C11-0.38, R2 = 0.96). Similarly, rheometry-derived G∗ at 1 Hz, increasing from 0.66 ± 1.03 kPa (1% strain) to 1.84 ± 1.65 kPa (30% strain, RM one-way ANOVA, P < 0.001), and the frequency dependence of G∗ followed a power-law with the exponent decreasing from 0.13 to 0.06 with increasing preload. MR elastography-derived G∗ was 1.4-3.1 times higher than the extrapolated rheometry-derived G∗ at 60 Hz, but the strain dependence was consistent between rheometry and MR elastography measurements. CONCLUSIONS This study demonstrates that MR elastography can detect changes in ex vivo bovine liver complex shear modulus due to either uniform or focal preload and therefore can be a useful technique to characterize nonlinear viscoelastic properties of soft tissue, provided that strains applied to the tissue can be quantified. Although MR elastography could reliably characterize the strain dependence of the ex vivo bovine liver, MR elastography overestimated the complex shear modulus of the tissue compared to rheological measurements, particularly at lower preload (<10%). That is likely to be important in clinical hepatic MR elastography diagnosis studies if preload is not carefully considered. A limitation is the absence of overlapping frequency between rheometry and MR elastography for formal validation.
Collapse
Affiliation(s)
- Lauriane Jugé
- Neuroscience Research Australia, PO Box 1165, Randwick NSW 2031, Australia; University of New South Wales, Faculty of Medicine & Health, UNSW Sydney, 18 High St, Kensington NSW 2052, Australia
| | - Patrick Foley
- Neuroscience Research Australia, PO Box 1165, Randwick NSW 2031, Australia
| | - Alice Hatt
- Neuroscience Research Australia, PO Box 1165, Randwick NSW 2031, Australia
| | - Jade Yeung
- Neuroscience Research Australia, PO Box 1165, Randwick NSW 2031, Australia
| | - Lynne E Bilston
- Neuroscience Research Australia, PO Box 1165, Randwick NSW 2031, Australia; University of New South Wales, Faculty of Medicine & Health, UNSW Sydney, 18 High St, Kensington NSW 2052, Australia.
| |
Collapse
|
3
|
Im WH, Song JS, Jang W. Noninvasive staging of liver fibrosis: review of current quantitative CT and MRI-based techniques. Abdom Radiol (NY) 2022; 47:3051-3067. [PMID: 34228199 DOI: 10.1007/s00261-021-03181-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Revised: 06/12/2021] [Accepted: 06/14/2021] [Indexed: 01/18/2023]
Abstract
Liver fibrosis features excessive protein accumulation in the liver interstitial space resulting from repeated tissue injury due to chronic liver disease. Liver fibrosis eventually proceeds to cirrhosis and associated complications. So, early diagnosis and staging of liver fibrosis are of vital importance for clinical treatment. Liver biopsy remains the gold standard for the diagnosing and staging of fibrosis, but it is suboptimal due to various limitations. Recently, efforts have been made to migrate toward noninvasive techniques for assessing liver fibrosis. CT is relatively easy to perform, relatively standardized for different scanners, and does not require additional hardware in liver fibrosis staging. MRI is frequently performed to characterize indeterminate liver lesions. Because it does not use ionizing radiation and features high image contrast, its role has increased in the staging of liver fibrosis. More recently, several studies on liver fibrosis staging using deep learning algorithms in CT or MRI have been proposed and have shown meaningful results. In this review, we summarize the basic concept, diagnostic performance, and advantages and limitations of each technique to noninvasively stage liver fibrosis.
Collapse
Affiliation(s)
- Won Hyeong Im
- Department of Radiology, The 3rd Flying Training Wing, Sacheon, 52516, South Korea
| | - Ji Soo Song
- Department of Radiology, Jeonbuk National University Medical School and Hospital, 20 Geonji-ro, Deokjin-gu, Jeonju, 54907, Jeonbuk, South Korea.
- Research Institute of Clinical Medicine of Jeonbuk National University, Jeonju, South Korea.
- Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, South Korea.
| | - Weon Jang
- Department of Radiology, Jeonbuk National University Medical School and Hospital, 20 Geonji-ro, Deokjin-gu, Jeonju, 54907, Jeonbuk, South Korea
- Research Institute of Clinical Medicine of Jeonbuk National University, Jeonju, South Korea
- Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, South Korea
| |
Collapse
|
4
|
Daly M, McWilliam A, Radhakrishna G, Choudhury A, Eccles CL. Radiotherapy respiratory motion management in hepatobiliary and pancreatic malignancies: a systematic review of patient factors influencing effectiveness of motion reduction with abdominal compression. Acta Oncol 2022; 61:833-841. [PMID: 35611555 DOI: 10.1080/0284186x.2022.2073186] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 04/28/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND The effectiveness of abdominal compression for motion management in hepatobiliary-pancreatic (HPB) radiotherapy has not been systematically evaluated. METHODS & MATERIALS A systematic review was carried out using PubMed/Medline, Cochrane Library, Web of Science, and CINAHL databases up to 1 July 2021. No date restrictions were applied. Additional searches were carried out using the University of Manchester digital library, Google Scholar and of retrieved papers' reference lists. Studies conducted evaluating respiratory motion utilising imaging with and without abdominal compression in the same patients available in English were included. Studies conducted in healthy volunteers or majority non-HPB sites, not providing descriptive motion statistics or patient characteristics before and after compression in the same patients or published without peer-review were excluded. A narrative synthesis was employed by tabulating retrieved studies and organising chronologically by abdominal compression device type to help identify patterns in the evidence. RESULTS The inclusion criteria were met by 6 studies with a total of 152 patients. Designs were a mix of retrospective and prospective quantitative designs with chronological, non-randomised recruitment. Abdominal compression reduced craniocaudal respiratory motion in the majority of patients, although in four studies there were increases seen in at least one direction. The influence of patient comorbidities on effectiveness of compression, and/or comfort with compression was not evaluated in any study. CONCLUSION Abdominal compression may not be appropriate for all patients, and benefit should be weighed with potential increase in motion or discomfort in patients with small initial motion (<5 mm). Patient factors including male sex, and high body mass index (BMI) were found to impact the effectiveness of compression, however with limited evidence. High-quality studies are warranted to fully assess the clinical impact of abdominal compression on treatment outcomes and toxicity prospective in comparison to other motion management strategies.
Collapse
Affiliation(s)
- Mairead Daly
- Division of Clinical Cancer Sciences, Faculty of Biology, Medicine and Health, School of Medical Sciences, The University of Manchester, Manchester, United Kingdom
| | - Alan McWilliam
- Division of Clinical Cancer Sciences, Faculty of Biology, Medicine and Health, School of Medical Sciences, The University of Manchester, Manchester, United Kingdom
- The Christie NHSFT, Manchester, United Kingdom
| | | | - Ananya Choudhury
- Division of Clinical Cancer Sciences, Faculty of Biology, Medicine and Health, School of Medical Sciences, The University of Manchester, Manchester, United Kingdom
- The Christie NHSFT, Manchester, United Kingdom
| | - Cynthia L Eccles
- Division of Clinical Cancer Sciences, Faculty of Biology, Medicine and Health, School of Medical Sciences, The University of Manchester, Manchester, United Kingdom
- The Christie NHSFT, Manchester, United Kingdom
| |
Collapse
|
5
|
Chouhan MD, Fitzke HE, Bainbridge A, Atkinson D, Halligan S, Davies N, Lythgoe MF, Mookerjee RP, Menys A, Taylor SA. Cardiac-induced liver deformation as a measure of liver stiffness using dynamic imaging without magnetization tagging-preclinical proof-of-concept, clinical translation, reproducibility and feasibility in patients with cirrhosis. Abdom Radiol (NY) 2021; 46:4660-4670. [PMID: 34148103 DOI: 10.1007/s00261-021-03168-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 06/03/2021] [Accepted: 06/05/2021] [Indexed: 12/13/2022]
Abstract
PURPOSE MR elastography and magnetization-tagging use liver stiffness (LS) measurements to diagnose fibrosis but require physical drivers, specialist sequences and post-processing. Here we evaluate non-rigid registration of dynamic two-dimensional cine MRI images to measure cardiac-induced liver deformation (LD) as a measure of LS by (i) assessing preclinical proof-of-concept, (ii) clinical reproducibility and inter-reader variability, (iii) the effects of hepatic hemodynamic changes and (iv) feasibility in patients with cirrhosis. METHODS Sprague-Dawley rats (n = 21 bile duct ligated (BDL), n = 17 sham-operated controls) and fasted patients with liver cirrhosis (n = 11) and healthy volunteers (HVs, n = 10) underwent spoiled gradient-echo short-axis cardiac cine MRI studies at 9.4 T (rodents) and 3.0 T (humans). LD measurements were obtained from intrahepatic sub-cardiac regions-of-interest close to the diaphragmatic margin. One-week reproducibility and prandial stress induced hemodynamic changes were assessed in healthy volunteers. RESULTS Normalized LD was higher in BDL (1.304 ± 0.062) compared with sham-operated rats (1.058 ± 0.045, P = 0.0031). HV seven-day reproducibility Bland-Altman (BA) limits-of-agreement (LoAs) were ± 0.028 a.u. and inter-reader variability BA LoAs were ± 0.030 a.u. Post-prandial LD increases were non-significant (+ 0.0083 ± 0.0076 a.u., P = 0.3028) and uncorrelated with PV flow changes (r = 0.42, p = 0.2219). LD measurements successfully obtained from all patients were not significantly higher in cirrhotics (0.102 ± 0.0099 a.u.) compared with HVs (0.080 ± 0.0063 a.u., P = 0.0847). CONCLUSION Cardiac-induced LD is a conceptually reasonable approach from preclinical studies, measurements demonstrate good reproducibility and inter-reader variability, are less likely to be affected by hepatic hemodynamic changes and are feasible in patients with cirrhosis.
Collapse
Affiliation(s)
- Manil D Chouhan
- Division of Medicine, Centre for Medical Imaging, University College London (UCL), London, UK.
| | - Heather E Fitzke
- Division of Medicine, Centre for Medical Imaging, University College London (UCL), London, UK
- Wingate Institute of Neurogastroenterology, Neuroscience and Trauma, Queen Mary University of London (QMUL), London, UK
| | - Alan Bainbridge
- Department of Medical Physics, University College London Hospitals NHS Trust, London, UK
| | - David Atkinson
- Division of Medicine, Centre for Medical Imaging, University College London (UCL), London, UK
| | - Steve Halligan
- Division of Medicine, Centre for Medical Imaging, University College London (UCL), London, UK
| | - Nathan Davies
- Division of Medicine, Institute for Liver and Digestive Health, University College London (UCL), London, UK
| | - Mark F Lythgoe
- Division of Medicine, Centre for Advanced Biomedical Imaging, University College London (UCL), London, UK
| | - Rajeshwar P Mookerjee
- Division of Medicine, Institute for Liver and Digestive Health, University College London (UCL), London, UK
| | - Alex Menys
- Division of Medicine, Centre for Medical Imaging, University College London (UCL), London, UK
- Motilent, London, UK
| | - Stuart A Taylor
- Division of Medicine, Centre for Medical Imaging, University College London (UCL), London, UK
| |
Collapse
|
6
|
Mella H, Wang H, Montalba C, Uribe S. An off-resonance insensitive orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half scan time. Magn Reson Med 2021; 86:3022-3033. [PMID: 34254351 DOI: 10.1002/mrm.28916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/25/2021] [Accepted: 06/15/2021] [Indexed: 11/08/2022]
Abstract
PURPOSE To develop an Off-Resonance Insensitive Orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half of the acquisition time. METHODS Phantom and mid-level left ventricle short-axis tagged images were acquired using CSPAMM, ORI-CSPAMM, O-CSPAMM, and the proposed ORI-O-CPAMM sequences to interrogate and compare its behavior under off-resonance effects produced by vegetable oil and subcutaneous and epicardial fat. The images were compared in terms of signal and the capacity to obtain complex difference and MICSR images. RESULTS Like ORI-CSPAMM, the proposed ORI-O-CSPAMM sequence removed almost completely the off-resonance artifacts produced during the tagging preparation. Tagging grids without DC components were obtained with ORI-O-CSPAMM using complex difference and MICSR from only two complementary images, which reduced the scan time to a half compared to CSPAMM and ORI-CSPAMM. The removal of off-resonance effects and the capacity to obtain MICSR images are advantages of ORI-O-CSPAMM over the O-CSPAMM sequence. CONCLUSION We developed a novel and fast tagging sequence designed to remove off-resonance effects during the tagging preparation, and to obtain complex difference and MICSR grids in half of the scan time compared to CSPAMM and ORI-CSPAMM sequences, which could allow its application to clinical protocols.
Collapse
Affiliation(s)
- Hernán Mella
- Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Región Metropolitana, Chile.,Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Región Metropolitana, Chile.,ANID - Millennium Science Initiative Program - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Región Metropolitana, Chile
| | - Hui Wang
- MR Clinical Science, Philips, Cincinnati, Ohio, USA.,Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Cristian Montalba
- Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Región Metropolitana, Chile.,ANID - Millennium Science Initiative Program - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Región Metropolitana, Chile
| | - Sergio Uribe
- Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Región Metropolitana, Chile.,ANID - Millennium Science Initiative Program - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Región Metropolitana, Chile.,Department of Radiology, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Región Metropolitana, Chile
| |
Collapse
|