1
|
Kiefer MK, Russo JR, Foy PM, Wu J, Landon MB, Frey HA. Cervical elastography at 18 to 23 weeks to predict spontaneous preterm birth in individuals with a history of preterm birth. AJOG GLOBAL REPORTS 2025; 5:100462. [PMID: 40103845 PMCID: PMC11915146 DOI: 10.1016/j.xagr.2025.100462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2025] Open
Abstract
BACKGROUND Individuals with a history of spontaneous preterm birth are at increased risk for recurrence in a subsequent pregnancy. Current methods used to predict those at highest risk are not precise. Cervical elastography is an investigational ultrasonographic technique that measures cervical tissue stiffness and may aid in identifying individuals at highest risk. OBJECTIVE This study aimed to assess the association between previously described cervical elastography measures-obtained using a semiautomatic application (E-cervix)-and preterm birth <37 weeks' gestation in a high-risk cohort with a history of spontaneous preterm birth. STUDY DESIGN Individuals with a singleton pregnancy between 18+0 and 23+6 weeks of gestation with a history of spontaneous preterm birth <37 weeks were prospectively enrolled. Exclusion criteria included the presence of a current cerclage or any uterine anomaly. The primary exposures were the E-cervix quantitative parameters (internal os stiffness, external os stiffness, internal-to-external os stiffness ratio, hardness ratio, and elasticity contrast index), which were measured at the time of enrollment. Transvaginal cervical length was also measured as an exposure to compare the current standard of care and accepted cutpoint of 25 mm alongside the E-cervix parameters. The primary outcome was preterm birth <37 weeks. The intra- and interrater reliability intraclass correlation coefficient for each parameter was calculated using a mixed-effects model. The area under the curve was derived from receiver operating characteristic curves to evaluate the association of each parameter with the primary outcome, and the optimal cutpoints for each continuous parameter were identified. Multivariable logistic regression was performed for the parameters that were either significant on univariate analysis or had an area under the curve of ≥0.6, using the calculated cutpoint to create a binary exposure and adjusting for gestational age at the earliest prior preterm birth, number of prior preterm births, and progesterone use. A sensitivity analysis was performed excluding medically indicated preterm birth. RESULTS Of the enrolled 245 individuals with a history of spontaneous preterm birth, 69 (28%) had preterm birth <37 weeks. Intrarater and interrater reliability were good for all parameters (intrarater: 0.60-0.74; interrater: 0.62-0.71). In univariate analysis, only the internal-to-external os stiffness ratio was significantly associated with increased risk of preterm birth compared with no preterm birth (0.97±0.23 vs 0.90±0.20; P=.01). Cervical length, internal os stiffness, external os stiffness, hardness ratio, and elasticity contrast index did not show significant associations. The area under the curve for external os stiffness was 0.6, indicating a good association, whereas the values for the remaining parameters were satisfactory (0.51-0.59). In multivariable logistic regression analysis, an internal-to-external os stiffness ratio ≥1.0 was associated with 2-fold higher odds of preterm birth <37 weeks (adjusted odds ratio, 2.48; confidence interval, 1.34-4.58), and an external os stiffness ≥30 (indicating lower tissue stiffness) was associated with 46% reduced odds of preterm birth <37 weeks (adjusted odds ratio, 0.54; confidence interval, 0.30-0.97). Cervical length <25 mm was not associated with preterm birth. CONCLUSION Elastography with E-cervix technology can be reliably assessed in a cohort of women with prior preterm birth. The parameter most useful for predicting preterm birth was an internal-to-external os stiffness ratio ≥1.0, whereas cervical length <25 mm was not predictive in our cohort.
Collapse
Affiliation(s)
- Miranda K Kiefer
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, The Ohio State University, Columbus, OH
| | - Jessica R Russo
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, The Ohio State University, Columbus, OH
| | - Pamela M Foy
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, The Ohio State University, Columbus, OH
| | - Jiqiang Wu
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, The Ohio State University, Columbus, OH
| | - Mark B Landon
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, The Ohio State University, Columbus, OH
| | - Heather A Frey
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, The Ohio State University, Columbus, OH
| |
Collapse
|
2
|
Alfuraih AM. The Emerging Role of Sonoelastography in Pregnancy: Applications in Assessing Maternal and Fetal Health. Diagnostics (Basel) 2024; 15:47. [PMID: 39795575 PMCID: PMC11720552 DOI: 10.3390/diagnostics15010047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2024] [Revised: 12/25/2024] [Accepted: 12/25/2024] [Indexed: 01/13/2025] Open
Abstract
Sonoelastography, a novel ultrasound-based technique, is emerging as a valuable tool in prenatal diagnostics by quantifying tissue elasticity and stiffness in vivo. This narrative review explores the application of sonoelastography in assessing maternal and fetal health, with a focus on cervical, placental, pelvic floor, and fetal tissue evaluations. In the cervix, sonoelastography aids in predicting preterm birth and assessing labor induction success. For the placenta, it provides insights into conditions like preeclampsia and intrauterine growth restriction through elasticity measurements. Assessing fetal tissues, including the lungs, liver, and brain, sonoelastography offers a non-invasive method for evaluating organ maturity and detecting developmental anomalies. Additionally, pelvic floor assessments enable better management of childbirth-related injuries and postpartum recovery. While current studies support its safety when used within established limits, further research is necessary to confirm long-term effects. Future advancements include refining protocols, integrating machine learning, and combining sonoelastography with other diagnostic methods to enhance its predictive power. Sonoelastography holds promise as an impactful adjunct to conventional ultrasound, providing quantitative insights that can improve maternal and fetal outcomes in prenatal care.
Collapse
Affiliation(s)
- Abdulrahman M Alfuraih
- Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj 16278, Saudi Arabia
| |
Collapse
|
3
|
He B, Zhou Y, Cao L, Yao B, Gao H, Zhang H. Cervical elastography in predicting spontaneous preterm birth in singleton pregnancy with a short cervix receiving progesterone treatment at 18 to 24 weeks' gestation. J Matern Fetal Neonatal Med 2024; 37:2347954. [PMID: 38714523 DOI: 10.1080/14767058.2024.2347954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 04/22/2024] [Indexed: 05/10/2024]
Abstract
BACKGROUND A short cervix in the second trimester is known to increase the risk of preterm birth, which can be reduced with the administration of vaginal progesterone. However, some studies have suggested that a significant number of cases still experience preterm birth despite progesterone treatment. OBJECTIVE This study was aimed to investigate the potential value of transvaginal cervical elasticity measured by E-Cervix as a predictor for spontaneous preterm birth (sPTB) in singleton pregnancies receiving progesterone treatment for a short cervix (CL ≤ 2.5 cm) diagnosed at 18 to 24 weeks' gestation. STUDY DESIGN This prospective study was conducted at a single center premature high-risk clinic from January 2020 to July 2022. Singleton pregnancies with a short cervix at 18 to 24 weeks' gestation were enrolled. Cervical elastography using E-Cervix was performed, and maternal and neonatal demographic characteristics, cervical length (CL), elasticity contrast index (ECI), cervical hardness ratio, mean internal os strain (IOS), and mean external os strain (EOS) were compared before and after progesterone treatment in sPTB and term birth groups. Multivariate logistic regression was used to analyze the association between elasticity parameters and spontaneous preterm birth. The screening performance of CL and optimal cervical elasticity parameters in predicting sPTB was evaluated using receiver-operating characteristic (ROC) curve analysis. RESULTS A total of 228 singleton pregnant women were included in the study, among which 26 (11.4%) had sPTB. There were no significant differences in maternal characteristics and gestational age at enrollment between women with and without sPTB. At the start of progesterone treatment, there were no significant differences in cervical elasticity parameters between the two groups. After two weeks of progesterone treatment, women who had sPTB showed significantly higher levels of ECI, IOS, EOS (p = 0.0108, 0.0001, 0.016), and lower hardness ratio (p = 0.011) compared to those who had a full-term birth. Cervical length did not show significant differences between the two groups, regardless of whether progesterone treatment was administered before or after. Among the post-treatment cervical elasticity parameters, IOS and EOS were associated with a 3.38-fold and 2.29-fold increase in the risk of sPTB before 37 weeks (p = 0.032, 0.047, respectively). The AUROC of the combined model including CL, IOS, and EOS (0.761, 95% CI0.589-0.833) was significantly higher than the AUROC of CL alone (0.618, 95% CI 0.359-0.876). At a fixed false-positive of 13%, the addition of IOS and EOS in the CL model increased sensitivity from 34.6% to 57.6%, PPV from 25.7% to 36.5%, and NPV from 91.1% to 94.1%. CONCLUSION When assessing the risk of sPTB in singleton pregnancies with a short cervix receiving progesterone therapy, relying solely on cervical length is insufficient. It is crucial to also evaluate cervical stiffness, particularly the strain of the internal and external os, using cervical elastography.
Collapse
Affiliation(s)
- Biyuan He
- Department of Ultrasound, Shanghai Changning Maternity and Infant Health Hospital, East China Normal University, Shanghai, China
| | - Yuqing Zhou
- Department of Ultrasound, Shanghai Changning Maternity and Infant Health Hospital, East China Normal University, Shanghai, China
| | - Li Cao
- Department of Ultrasound, Shanghai Changning Maternity and Infant Health Hospital, East China Normal University, Shanghai, China
| | - Bingyi Yao
- Department of Obstetrics, Shanghai Changning Maternity and Infant Health Hospital, East China Normal University, Shanghai, China
| | - Haihuan Gao
- Department of Ultrasound, Shanghai Changning Maternity and Infant Health Hospital, East China Normal University, Shanghai, China
| | - Huiping Zhang
- Department of Ultrasound, Shanghai Changning Maternity and Infant Health Hospital, East China Normal University, Shanghai, China
| |
Collapse
|
4
|
Vasudeva A, Kodavati H, Samanth J, Padavagodu Shivananda R, Paladugu S, Raghav M, Hanumaiah G, Chaudhuri S, Hegde N, Adiga P, Hebbar S, Kumar P. TVS-guided cervical strain elastography is more effective than measuring cervical length as an independent predictor of spontaneous preterm delivery in asymptomatic, high-risk women during the mid-trimester. J Matern Fetal Neonatal Med 2024; 37:2381589. [PMID: 39054066 DOI: 10.1080/14767058.2024.2381589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 07/12/2024] [Indexed: 07/27/2024]
Abstract
INTRODUCTION TVS (Transvaginal Sonography) guided Cervical strain elastography (CSE) is now available in tertiary referral centers of LMICs (Low- and Middle-Income Countries). TVS cervical length (CL) assessment is being used routinely. Still, elastography is not used in clinical settings, although enough evidence suggests good predictive value towards sPTD (spontaneous Preterm Delivery). The clinical utility of elastography has not been tested among high-risk populations of LMICs for the prediction of sPTD. AIM To test the performance of TVS-CSE in predicting sPTD among asymptomatic women in the mid-trimester at risk of sPTD either due to clinical factors or due to a short cervix. METHOD Prospective observational study performed at a tertiary hospital in South India. Asymptomatic pregnant women between 16 and 24 weeks who had one or more clinical risk factors for sPTD or CL <2.5 cm were included. GE Voluson E-8 ultrasound machine was used. After CL measurement, elastography color coding was noted around the internal-os in the sagittal view. The strain ratio (SR) was calculated using the trace method on three ROIs (Region of Interest): Internal-os in sagittal view (IN), whole cervix in sagittal view (WN), and internal-os in axial view (AN). Reference Tissue (RT) of similar size and depth was chosen in the darkest blue region on elastography (stiffest area) outside the cervix, posterior/lateral to the cervix over the ligament insertion. Lower the SR - softer the cervix. Two trained fetal medicine consultants performed the initial 57 cases until intra/inter-observer correlation was satisfactory. Delivery before 37 weeks (after 26 weeks), in which the process of labor has begun spontaneously, or labor was induced after PPROM-was considered as sPTD. SRs were assessed to determine how well they could predict sPTD independently or combined with cervical length. RESULTS Out of 221 recruited,17 were lost to follow-up after 32 weeks; 204 were delivered in our hospital. Irrespective of the route of delivery, 71 (34.8%) had sPTD. Of the remaining 133, 106 delivered at term, and 27 underwent medically indicated PTD. Apart from multiple pregnancies, no other preterm-related risk factors (including CL < 2.5 cm) showed significant association with sPTD. Red CSE pattern around internal-os was associated with a significantly higher (54.5%) incidence of sPTD. CLs were similar (3.63 ± 0.67 vs. 3.63 ± 0.80, p = .981) whereas SRs in all three ROIs were significantly lower among sPTD group versus no sPTD group (IN:0.65 ± 0.29 vs 0.79 ± 0.30 p = .001, WN:0.34 ± 0.13 vs 0.39 ± 0.15, p = .013, AN:0.37 ± 0.16 vs 0.48 ± 0.26, p = .002, respectively). Using ROC curves, while CL was not predictive (AUROC 0.49, p = .81), SRs showed moderate predictive value toward sPTD with the best AUC of 0.624 (p = .003) at IN. Prediction was slightly better for early sPTD <32 weeks (AUC 0.653 p = 0.03). The best cutoff for SR at IN was 0.72, below which there was a moderate accuracy in predicting sPTD (sensitivity 52.11%, specificity 60.9%, PPV 41.57%, NPV 70.44%, diagnostic OR 1.69 and overall accuracy of 57.84%). A weak positive correlation is seen between IN and CL (Pearson's correlation R = 0.181). Multi-variable binary logistic regression analysis suggested that SRs at IN (Adjusted OR - 0.259 CI 0.079-0.850), AN (Adjusted OR 0.182 CI 0.034-0.963), Multiple Pregnancy (Adjusted OR 3.5 CI 1.51-8.13) and previous sPTD/PPROM (Adjusted OR 2.72 CI 0.97-7.61) independently predicted sPTD. CONCLUSIONS TVS CSE performed better than CL as an independent predictive tool toward sPTD, although predictive efficacy was modest at best. Since technology is now available in high-end USG machines in tertiary care centers, we propose optimal utilization of CSE in LMICs to triage at-risk populations since low SRs are strongly associated with sPTD.
Collapse
Affiliation(s)
- Akhila Vasudeva
- Division of Fetal Medicine, Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Haritha Kodavati
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Jyothi Samanth
- Department of Cardiovascular Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Roopa Padavagodu Shivananda
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Sanghamitra Paladugu
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Mridula Raghav
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Gagana Hanumaiah
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Souvik Chaudhuri
- Department of Critical Care Medicine, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Nivedita Hegde
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Prashanth Adiga
- Department of Reproductive Medicine and Surgery, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Shripad Hebbar
- Department of Obstetrics and Gynaecology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Pratap Kumar
- Department of Reproductive Medicine and Surgery, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| |
Collapse
|
5
|
Sharma A, Thakur S, Tomar A, Mittal R, Surya M. Diagnostic accuracy of strain cervical elastography as a predictor for preterm delivery: A single tertiary care centre study. ULTRASOUND (LEEDS, ENGLAND) 2024:1742271X241277448. [PMID: 39610978 PMCID: PMC11600413 DOI: 10.1177/1742271x241277448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2024] [Accepted: 07/19/2024] [Indexed: 11/30/2024]
Abstract
Introduction Preterm delivery is a grave and demanding problem that accounts for the major cause of neonatal deaths and long-term morbidities. It remains an unresolved health issue of global dimensions. Cervical elastography is evolving as a useful diagnostic tool for its timely prediction so that individualised management can be done. Aim To assess the diagnostic accuracy of transvaginal strain cervical elastography in prediction of preterm delivery. Methods This prospective observational study was conducted from June 2021 to August 2022 in a tertiary care institute of North India. A total of 75 low-risk asymptomatic women were included. Transvaginal ultrasound was performed for the cervical length in the second and third trimesters. In addition, we collected strain elastography data such as colour codes from six regions of the cervix, that is, at the anterior and posterior lips of internal os, middle one-third of the cervix and the external os, and the strain ratios from these three cervical levels were also calculated. Then these parameters were compared with cervical length, second and third trimester groups and also with preterm and term delivery groups. Result The red colour (soft colour) at the anterior lip of internal os was the best predictor of preterm delivery in our study with a sensitivity and specificity of 63.64% and 96.87%, respectively. The elastography strain ratio of >2 at the internal os and cervical length ⩽2.8 cm were the additional predictors for the same. Conclusion Cervical elastography can serve as a potential and reliable predictor for preterm delivery.
Collapse
Affiliation(s)
| | | | | | - Rita Mittal
- Department of Obstetrics & Gynecology, KNHM&C, IGMC, Shimla, India
| | - Mukesh Surya
- Department of Radiodiagnosis, IGMC, Shimla, India
| |
Collapse
|
6
|
Lu H, Liu Y, Yang F, Wu D, Qi J, Ji Y, Hu M. The value of real-time shear wave elastography in spontaneous preterm birth. Medicine (Baltimore) 2024; 103:e39288. [PMID: 39151541 PMCID: PMC11332725 DOI: 10.1097/md.0000000000039288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/10/2024] [Accepted: 07/23/2024] [Indexed: 08/19/2024] Open
Abstract
This study aimed to investigate the predictive value of real-time shear wave elastography (SWE) for spontaneous preterm birth (SPB). This study prospectively selected 175 women with singleton pregnancies at 16 to 36 weeks of gestation. Cervical length (CL) and uterocervical angle (UCA) were measured using transvaginal ultrasonography. Real-time shear wave elastography was used to measure Young's modulus values, including the average Young's modulus (Emean) and the maximum Young's modulus (Emax) at 4 points: point A on the inner lip of the cervical os, point B on the outer lip of the cervical os, point C on the inner lip of the external os, and point D on the outer lip of the external os. Receiver operating characteristic (ROC) curve analysis was performed to compare the accuracy of Young's modulus values at the 4 points, CL, and UCA in predicting SPB. Significant variables were used to construct a binary logistic regression model to predict the multifactorial predictive value of SPB, which was evaluated using an ROC curve. A total 176 valid cases, including 160 full-term pregnancies and 16 SPB, were included in this study. Receiver operating characteristic curve analysis revealed that Emean at point A, as well as Emean and Emax at point D, had a relatively high accuracy in diagnosing SPB, with area under the curve values of 0.704, 0.708, and 0.706, respectively followed by CL (0.670), SWE at point C (Emean 0.615, Emax 0.565), SWE at point B (Emean 0.577, Emax 0.584), and UCA (0.476). Binary logistic regression analysis showed that comorbidities during pregnancy (including diabetes mellitus, hypertension, cholestasis and thyroid dysfunction), CL, and Emean at point A were independent predictors of preterm birth. In addition, the AUC value of the logistic regression model's ROC curve was 0.892 (95% CI: 0.804-0.981), with a sensitivity of 0.867, specificity of 0.792, and Youden's index of 0.659, indicating that the regression model has good predictive ability for SPB. Real-time shear wave elastography showed a higher predictive value for SPB than CL and UCA. The SWE combined with CL and comorbidities during pregnancy model has a good predictive ability for SPB.
Collapse
Affiliation(s)
- Huiling Lu
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Yang Liu
- Department of Gynecology, Baoji Central Hospital, Shaanxi, China
| | - Fangrui Yang
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Dan Wu
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Jiarui Qi
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Yonghao Ji
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Mengli Hu
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| |
Collapse
|
7
|
Zaniker EJ, Zhang M, Hughes L, La Follette L, Atazhanova T, Trofimchuk A, Babayev E, Duncan FE. Shear wave elastography to assess stiffness of the human ovary and other reproductive tissues across the reproductive lifespan in health and disease†. Biol Reprod 2024; 110:1100-1114. [PMID: 38609185 PMCID: PMC11180622 DOI: 10.1093/biolre/ioae050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 03/15/2024] [Accepted: 03/20/2024] [Indexed: 04/14/2024] Open
Abstract
The ovary is one of the first organs to show overt signs of aging in the human body, and ovarian aging is associated with a loss of gamete quality and quantity. The age-dependent decline in ovarian function contributes to infertility and an altered endocrine milieu, which has ramifications for overall health. The aging ovarian microenvironment becomes fibro-inflammatory and stiff with age, and this has implications for ovarian physiology and pathology, including follicle growth, gamete quality, ovulation dynamics, and ovarian cancer. Thus, developing a non-invasive tool to measure and monitor the stiffness of the human ovary would represent a major advance for female reproductive health and longevity. Shear wave elastography is a quantitative ultrasound imaging method for evaluation of soft tissue stiffness. Shear wave elastography has been used clinically in assessment of liver fibrosis and characterization of tendinopathies and various neoplasms in thyroid, breast, prostate, and lymph nodes as a non-invasive diagnostic and prognostic tool. In this study, we review the underlying principles of shear wave elastography and its current clinical uses outside the reproductive tract as well as its successful application of shear wave elastography to reproductive tissues, including the uterus and cervix. We also describe an emerging use of this technology in evaluation of human ovarian stiffness via transvaginal ultrasound. Establishing ovarian stiffness as a clinical biomarker of ovarian aging may have implications for predicting the ovarian reserve and outcomes of Assisted Reproductive Technologies as well as for the assessment of the efficacy of emerging therapeutics to extend reproductive longevity. This parameter may also have broad relevance in other conditions where ovarian stiffness and fibrosis may be implicated, such as polycystic ovarian syndrome, late off target effects of chemotherapy and radiation, premature ovarian insufficiency, conditions of differences of sexual development, and ovarian cancer. Summary sentence: Shear Wave Elastography is a non-invasive technique to study human tissue stiffness, and here we review its clinical applications and implications for reproductive health and disease.
Collapse
Affiliation(s)
- Emily J Zaniker
- Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Man Zhang
- Department of Radiology, Michigan Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Lydia Hughes
- Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | | | - Tomiris Atazhanova
- Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Alexis Trofimchuk
- Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Elnur Babayev
- Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Francesca E Duncan
- Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
- Center for Reproductive Longevity and Equality, Buck Institute for Research on Aging, Novato, CA, USA
| |
Collapse
|
8
|
Egorov V, Rosen T, Hill J, Khandelwal M, Kurtenoks V, Francy B, Sarvazyan N. Evaluating the Efficacy of Cervical Tactile Ultrasound Technique as a Predictive Tool for Spontaneous Preterm Birth. OPEN JOURNAL OF OBSTETRICS AND GYNECOLOGY 2024; 14:832-846. [PMID: 38845755 PMCID: PMC11155442 DOI: 10.4236/ojog.2024.145067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/09/2024]
Abstract
Background Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results CM examination data were analyzed for 127 women at 240/7 - 286/7 gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group's 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10-4. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner.
Collapse
Affiliation(s)
| | - Todd Rosen
- Department of Obstetrics, Gynecology and Reproductive Sciences, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA
| | - Jennifer Hill
- Department of Obstetrics, Gynecology and Reproductive Sciences, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA
| | - Meena Khandelwal
- Department of Maternal-Fetal Medicine, Cooper Medical School of Rowan University, Camden, New Jersey, USA
| | | | | | | |
Collapse
|
9
|
Cheung KW, Au TST, Li J, Seto MTY. First-trimester and early-second-trimester transvaginal cervical length before 16 weeks among women with preterm and term birth: a systematic review and meta-analysis. Am J Obstet Gynecol MFM 2024; 6:101282. [PMID: 38242499 DOI: 10.1016/j.ajogmf.2024.101282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/27/2023] [Accepted: 01/03/2024] [Indexed: 01/21/2024]
Abstract
OBJECTIVE This study aimed to evaluate the differences in first-trimester and early-second-trimester transvaginal cervical length between patients with spontaneous preterm birth and those with term birth. DATA SOURCES PubMed, MEDLINE, Embase, and the Cochrane Library were systematically searched through August 2023. STUDY ELIGIBILITY CRITERIA Studies had to include (1) transvaginal cervical length measurement before 16+0 weeks of gestation and (2) transvaginal cervical length measurement in a population of patients who delivered preterm and at term. Abstracts, studies with duplicated data, and those with cervical length measured by transabdominal ultrasound scan were excluded. METHODS K.W.C. and J.L. searched for, screened, and reviewed the articles independently. The quality of the studies was assessed using the Newcastle-Ottawa scale. Mean differences were calculated using a random-effects model and pooled through a meta-analysis. RESULTS A total of 5727 published articles were identified. Only 10 studies (which analyzed 22,151 pregnancies) met the inclusion criteria. All studies excluded iatrogenic preterm birth. Transvaginal cervical length was significantly shorter in women with spontaneous preterm birth than in those who delivered at term (mean difference, -0.97; 95% confidence interval, -1.65 to -0.29; P=.005; I2=69%). When a linear technique was used to measure transvaginal cervical length, a significantly shorter transvaginal cervical length was associated with spontaneous preterm birth as opposed to term birth (mean difference, -1.09; 95% confidence interval, -1.96 to -0.21; P=.02; I2=77%). A shorter transvaginal cervical length measured by other techniques was also associated with spontaneous preterm birth before 34 to 35 weeks (mean difference, -1.87; 95% confidence interval, -3.04 to -0.70; P=.002; I2=0%). When studies where interventions were given for a "short" cervix or studies with a mean transvaginal cervical length ≥40 mm were excluded, a significantly shorter transvaginal cervical length was observed among those with spontaneous preterm birth (mean difference, -1.13; 95% confidence interval, -1.89 to -0.37; P=.004; mean difference, -0.86; 95% confidence interval, -1.67 to -0.04; P=.04; respectively). The optimal transvaginal cervical length cutoff was 38 to 39 mm, yielding pooled sensitivity of 0.80, specificity of 0.45, positive likelihood ratio of 1.16, negative likelihood ratio of 0.33, diagnostic odds ratio of 5.12, and an area under the curve of 0.75. CONCLUSION Women with spontaneous preterm birth had significantly shorter transvaginal cervical length before 16 weeks of gestation compared with those who delivered at term. The linear method and the 2-line method are acceptable techniques for measuring transvaginal cervical length.
Collapse
Affiliation(s)
- Ka Wang Cheung
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China.
| | - Tiffany Sin-Tung Au
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Justin Li
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Mimi Tin Yan Seto
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China
| |
Collapse
|
10
|
Janssen MK, Koelper N, Weatherby M, Werth C, Schwartz N. Evaluation of Non-Compressive Transvaginal Cervical Elastography as a Quantitative Imaging Biomarker in Pregnancy: A Repeatability and Reliability Analysis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:33-43. [PMID: 37732906 DOI: 10.1002/jum.16331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 08/18/2023] [Accepted: 08/28/2023] [Indexed: 09/22/2023]
Abstract
OBJECTIVES Non-compressive strain elastography has been proposed as a novel quantitative imaging biomarker for assessing the structure and function of the cervix. The current study aims to assess the repeatability, and intra- and inter-observer reliability of transvaginal non-compressive cervical strain elastography in a clinical setting. METHODS We conducted a dual-phase single-center prospective feasibility study of singleton gestations >16-weeks gestation that required a clinically-indicated transvaginal ultrasound. Each study participant, n = 43 in phase 1 and n = 13 in phase 2, had elastography performed by two trained observers that each performed multiple image acquisitions. We performed a multivariable regression to adjust for changes in clinical characteristics between study phases and calculated the repeatability coefficients, limits of agreement, and intraclass correlations for each quantitative elastography parameter. We compared quantitative elastography parameters to cervical length measurements, acquired from the same images. RESULTS The repeatability coefficients and percent limits of agreement were wide for all of the quantitative elastography parameters, demonstrating poor repeatability. Intraclass correlation coefficients were poor-moderate for both intra-observer (0.31-0.77) and inter-observer reliability (0.35-0.77) in both study phases, while cervical length showed excellent reliability with intraclass correlations consistently >0.90. CONCLUSIONS Non-compressive transvaginal strain cervical elastography did not demonstrate adequate repeatability or reliability. Our results highlight the importance of rigorously assessing novel quantitative imaging biomarkers before clinical application.
Collapse
Affiliation(s)
- Matthew K Janssen
- Maternal Fetal Medicine Research Program, Department of Obstetrics and Gynecology, The University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA
| | - Nathan Koelper
- Center for Epidemiology and Biostatistics, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Michele Weatherby
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Christina Werth
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Nadav Schwartz
- Maternal Fetal Medicine Research Program, Department of Obstetrics and Gynecology, The University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA
| |
Collapse
|
11
|
Li J, Wu Q, Chen Y, Wang J, Yan Y, Deng D, Huang R. Addition of cervical elastosonography to cervical length to predict preterm birth in pregnancy women with prior preterm birth: A preliminary prospective study. J Gynecol Obstet Hum Reprod 2023; 52:102617. [PMID: 37308039 DOI: 10.1016/j.jogoh.2023.102617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 06/01/2023] [Accepted: 06/04/2023] [Indexed: 06/14/2023]
Abstract
OBJECTIVES To investigate the characteristics of cervical elastosonography in pregnancies and establish an ultrasound-based combing predictor for improving the prediction in pregnant women with prior-preterm birth who might ultimately undergo preterm birth (PTB). MATERIALS AND METHODS 169 singleton pregnancies with prior-preterm birth were examined by cervical elastography from January to November of 2021. According to the ultrasound image and result of the following-up, the patients were separated into preterm groups and full-term groups with or without cerclage. There were five elastographic parameters: Elasticity Contrast Index (ECI), Cervical hard tissue Elasticity Ratio (CHR), External Cervical os Strain rate (ES), Closed Internal Cervical os Strain rate (CIS), CIS/ES ratio and CLmin. Multivariable logistic regression was used to screen out the most significant predictors. The area under the receiver operating characteristic curve (AUC) was calculated to evaluate the ability of prediction. RESULTS The PTB group without cerclage showed significantly softer cervix stiffness, while those with cerclage showed significantly harder. CHRmin with P < 0.05 in the univariate logistic regression analysis was screened as a more valuable cervical elastosonography parameter than other ones. The combination of CLmin and CHRmin in un-cerclage and integrating CHRmin, maternal age and pre-pregnancy BMI in cerclage presented good predictive value. The results of AUC were higher than CLmin, respectively (0.775 vs 0.734, 0.729 vs 0.548). CONCLUSIONS The addition of cervical elastography parameters (such as CHRmin) might improve the ability to predict preterm birth in pregnant women with previous preterm delivery, which was better than using CL alone.
Collapse
Affiliation(s)
- Jinghua Li
- Department of Ultrasound, Beijing Obstetrics and Gynecology Hospital, Capital Medical University. Beijing Maternal and Child Health Care Hospital, Beijing 100026, China.
| | - Qingqing Wu
- Department of Ultrasound, Beijing Obstetrics and Gynecology Hospital, Capital Medical University. Beijing Maternal and Child Health Care Hospital, Beijing 100026, China.
| | - Yi Chen
- Department of Obstetrics, Beijing Obstetrics and Gynecology Hospital, Capital Medical University. Beijing Maternal and Child Health Care Hospital, Beijing 100026, China
| | - Jingjing Wang
- Department of Ultrasound, Beijing Obstetrics and Gynecology Hospital, Capital Medical University. Beijing Maternal and Child Health Care Hospital, Beijing 100026, China
| | - Yan Yan
- Capital Medical University of Biomedical Engineering, Beijing 100069, China
| | - Di Deng
- Department of Ultrasound, Beijing Obstetrics and Gynecology Hospital, Capital Medical University. Beijing Maternal and Child Health Care Hospital, Beijing 100026, China
| | - Ruizhen Huang
- Department of Ultrasound, Beijing Obstetrics and Gynecology Hospital, Capital Medical University. Beijing Maternal and Child Health Care Hospital, Beijing 100026, China
| |
Collapse
|
12
|
Sun H, Lv Q, Liu T, Zhang N, Shi F. Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis. Scott Med J 2023; 68:110-120. [PMID: 37259580 DOI: 10.1177/00369330231178910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVE Cervical elastography has been used in pregnant women to diagnose preterm births. However, there is a variability in the measured elasticity parameters and imaging mode used. We evaluated the precision of cervical elastography in identifying preterm births. METHODS Extensive and methodical searches were made in the databases such as Scopus, Embase, Cochrane Library, PubMed Central, Medline, ScienceDirect, and Google Scholar from the inception until November 2022, for studies that report diagnostic accuracy of cervical elastography for preterm deliveries in antenatal women. RESULTS The pooled sensitivity and specificity value of cervical elastography for preterm deliveries were 82% (95%CI: 73%-89%) and 77% (95%CI: 64%-86%), respectively with area under curve (AUC) of 0.87 (95%CI: 0.72-0.95). The diagnostic odds ratio (DOR) was 15 (95%CI: 8-28), positive likelihood ratio (LRP) was 3.5 (95%CI: 2.3-5.5) and negative likelihood ratio LRN was 0.23 (0.16-0.34). Pooled sensitivity and specificity of shear wave elastography was 88% and 71%, respectively. Pooled sensitivity and specificity of strain elastography was 80% and 79%, respectively. Heterogeneity was significant, as indicated by chi-square test and an I2 statistic of over 75. CONCLUSIONS Cervical elastography can be used for predicting preterm deliveries with moderate to high level of accuracy.
Collapse
Affiliation(s)
- Hui Sun
- Department of Special Inspection, Qingdao Women and Children's Hospital, Qingdao City, Shandong Province, China
| | - Qifeng Lv
- Department of Cardiac Ultrasound, Affiliated Hospital of Qingdao University, Qingdao City, Shandong Province, China
| | - Tingting Liu
- Department of Ultrasound, Weifang People's Hospital, Weifang City, Shandong Province, China
| | - Nan Zhang
- Department of Ultrasound, Affiliated Hospital of Qingdao University, Qingdao City, Shandong Province, China
| | - Fengfeng Shi
- Department of Abdominal Ultrasound, Affiliated Hospital of Qingdao University, Qingdao City, Shandong Province, China
| |
Collapse
|
13
|
Luca AM, Haba R, Cobzeanu LM, Nemescu D, Harabor A, Mogos R, Adam AM, Harabor V, Nechita A, Adam G, Carauleanu A, Scripcariu SI, Vasilache IA, Gisca T, Socolov D. Predicting Preterm Birth with Strain Ratio Analysis of the Internal Cervical Os: A Prospective Study. J Clin Med 2023; 12:3885. [PMID: 37373580 DOI: 10.3390/jcm12123885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 05/27/2023] [Accepted: 06/05/2023] [Indexed: 06/29/2023] Open
Abstract
(1) Background: Cervical elastography is a new concept that could allow clinicians to assess cervical consistency in various clinical scenarios. We aimed to evaluate the predictive performance of the strain ratio (SR) at the level of the internal os, either individually or in combination with other parameters, in the prediction of spontaneous preterm birth (PTB) at various gestational ages. (2) Methods: This prospective study included 114 pregnant patients with a high-risk profile for PTB who underwent cervical elastography during the second trimester. Clinical and paraclinical data were assessed using univariate analysis, logistic regression, and sensitivity analysis. (3) Results: The SR achieved an area under the receiver operating curve (AUROC) value of 0.850, a sensitivity of 85.71%, and a specificity of 84.31% in the prediction of PTB before 37 weeks of gestation. The combined model showed superior results in terms of accuracy (AUROC = 0.938), sensitivity (92.31%), and specificity (95.16%). When considering PTB subtypes, the highest AUROC value (0.80) and accuracy (95.61%) of this marker were achieved in the prediction of extremely preterm birth, before 28 weeks of gestation. (4) Conclusions: The SR achieved an overall good predictive performance in the prediction of PTB and could be further evaluated in various cohorts of patients.
Collapse
Affiliation(s)
- Alina-Madalina Luca
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Raluca Haba
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Luiza-Maria Cobzeanu
- Surgical Department, Faculty of Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania
| | - Dragos Nemescu
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Anamaria Harabor
- Clinical and Surgical Department, Faculty of Medicine and Pharmacy, 'Dunarea de Jos' University, 800216 Galati, Romania
| | - Raluca Mogos
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Ana-Maria Adam
- Clinical and Surgical Department, Faculty of Medicine and Pharmacy, 'Dunarea de Jos' University, 800216 Galati, Romania
| | - Valeriu Harabor
- Clinical and Surgical Department, Faculty of Medicine and Pharmacy, 'Dunarea de Jos' University, 800216 Galati, Romania
| | - Aurel Nechita
- Clinical and Surgical Department, Faculty of Medicine and Pharmacy, 'Dunarea de Jos' University, 800216 Galati, Romania
| | - Gigi Adam
- Department of Pharmaceutical Sciences, Faculty of Medicine and Pharmacy, 'Dunarea de Jos' University, 800216 Galati, Romania
| | - Alexandru Carauleanu
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Sadiye-Ioana Scripcariu
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Ingrid-Andrada Vasilache
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Tudor Gisca
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Demetra Socolov
- Department of Obstetrics and Gynecology, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| |
Collapse
|
14
|
Wang XL, Lin S, Lyu GR. Advances in the clinical application of ultrasound elastography in uterine imaging. Insights Imaging 2022; 13:141. [PMID: 36057675 PMCID: PMC9440970 DOI: 10.1186/s13244-022-01274-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 07/20/2022] [Indexed: 11/10/2022] Open
Abstract
Changes in tissue stiffness by physiological or pathological factors in tissue structure are identified earlier than their clinical features. Pathological processes such as uterine fibrosis, adenomyosis, endometrial lesions, infertility, and premature birth can manifest as tissue elasticity changes. In clinical settings, elastography techniques based on ultrasonography, optical coherence tomography, and magnetic resonance imaging are widely used for noninvasive measurement of mechanical properties in patients, providing valuable tool and information for diagnosis and treatment. Ultrasound elastography (USE) plays a critical role in obstetrics and gynecology clinical work because of its simplicity, non-invasiveness, and repeatability. This article reviews the recent progress of USE in uterine tumor diagnosis (especially early diagnosis and treatment effect evaluation), prediction of preterm birth, and intrauterine insemination. We believe that USE, especially shear wave elastography, may serve as a potential means to assess tissue stiffness, thereby improving the diagnosis and treatment of adenomyosis, fibroids, endometrial lesions, cervical cancer, and precise management of preterm birth and intrauterine insemination monitoring.
Collapse
Affiliation(s)
- Xia-Li Wang
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, No. 34 North Zhongshan Road, Quanzhou, 362000, Fujian Province, China.,Department of Clinical Medicine, Quanzhou Medical College, Quanzhou, 362000, Fujian Province, China
| | - Shu Lin
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, No. 34 North Zhongshan Road, Quanzhou, 362000, Fujian Province, China. .,Centre of Neurological and Metabolic Research, The Second Affiliated Hospital of Fujian Medical University, No. 34 North Zhongshan Road, Quanzhou, 362000, Fujian Province, China. .,Diabetes and Metabolism Division, Garvan Institute of Medical Research, 384 Victoria Street, Darlinghurst, Sydney, NSW, 2010, Australia.
| | - Guo-Rong Lyu
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, No. 34 North Zhongshan Road, Quanzhou, 362000, Fujian Province, China. .,Department of Clinical Medicine, Quanzhou Medical College, Quanzhou, 362000, Fujian Province, China.
| |
Collapse
|
15
|
Cha HH, Seong WJ, Kim HM, Seol HJ, Sung JH, Park HS, Hwang HS, Kwon H, Jung YJ, Kwon JY, Oh SY. Midtrimester cervical elastography in pregnant women with a history of loop electrosurgical excision procedure (LEEP). Sci Rep 2022; 12:9191. [PMID: 35655076 PMCID: PMC9163180 DOI: 10.1038/s41598-022-13170-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 05/20/2022] [Indexed: 11/10/2022] Open
Abstract
We aimed to compare cervical elastographic parameters based on a previous loop electrosurgical excision procedure (LEEP) and to determine whether they can predict preterm delivery in pregnant women with a history of LEEP. This multicenter prospective case-control study included 71 singleton pregnant women at 14-24 weeks of gestation with a history of LEEP and 1:2 gestational age-matched controls. We performed cervical elastography using E-cervix and compared maternal characteristics, delivery outcomes, cervical length (CL), and elastographic parameters between the two groups. The median mid-trimester CL was significantly shorter in the LEEP group. Most elastographic parameters, including internal os (IOS), external os (EOS), elasticity contrast index (ECI), and hardness ratio (HR), were significantly different in the two groups. In the LEEP group, the sPTD group compared to the term delivery (TD) group showed a higher rate of previous sPTD (50% vs. 1.7%, p < 0.001), higher IOS and ECI (IOS: 0.28 [0.12-0.37] vs. 0.19 [0.10-0.37], p = 0.029; ECI: 3.89 [1.79-4.86] vs. 2.73 [1.48-5.43], p = 0.019), and lower HR (59.97 [43.88-92.43] vs. 79.06 [36.87-95.40], p = 0.028), but there was no significant difference in CL (2.92 [2.16-3.76] vs. 3.13 [1.50-3.16], p = 0.247). In conclusion, we demonstrated that a history of LEEP was associated with a change in cervical strain measured in mid-trimester as well as with CL shortening. We also showed that cervical elastography can be useful in predicting sPTD in pregnant women with previous LEEP.
Collapse
Affiliation(s)
- Hyun-Hwa Cha
- Department of Obstetrics and Gynecology, School of Medicine, Kyungpook National University Chilgok Hospital, Kyungpook National University, Daegu, Korea
| | - Won Joon Seong
- Department of Obstetrics and Gynecology, School of Medicine, Kyungpook National University Chilgok Hospital, Kyungpook National University, Daegu, Korea
| | - Hyun Mi Kim
- Department of Obstetrics and Gynecology, School of Medicine, Kyungpook National University Chilgok Hospital, Kyungpook National University, Daegu, Korea
| | - Hyun-Joo Seol
- Department of Obstetrics and Gynecology, Kyung Hee University School of Medicine, Seoul, Korea
| | - Ji-Hee Sung
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Korea
| | - Hyun Soo Park
- Department of Obstetrics and Gynecology, Graduate School of Medicine, Dongguk University, Goyang, Korea
| | - Han-Sung Hwang
- Department of Obstetrics and Gynecology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Hayan Kwon
- Department of Obstetrics and Gynecology, Institute of Women's Life Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Yun Ji Jung
- Department of Obstetrics and Gynecology, Institute of Women's Life Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Ja-Young Kwon
- Department of Obstetrics and Gynecology, Institute of Women's Life Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Soo-Young Oh
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Korea.
| |
Collapse
|
16
|
Machine Learning-Based Prediction Model of Preterm Birth Using Electronic Health Record. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:9635526. [PMID: 35463669 PMCID: PMC9020923 DOI: 10.1155/2022/9635526] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 02/26/2022] [Accepted: 03/14/2022] [Indexed: 11/18/2022]
Abstract
Objective Preterm birth (PTB) was one of the leading causes of neonatal death. Predicting PTB in the first trimester and second trimester will help improve pregnancy outcomes. The aim of this study is to propose a prediction model based on machine learning algorithms for PTB. Method Data for this study were reviewed from 2008 to 2018, and all the participants included were selected from a hospital in China. Six algorisms, including Naive Bayesian (NBM), support vector machine (SVM), random forest tree (RF), artificial neural networks (ANN), K-means, and logistic regression, were used to predict PTB. The receiver operating characteristic curve (ROC), accuracy, sensitivity, and specificity were used to assess the performance of the model. Results A total of 9550 pregnant women were included in the study, of which 4775 women had PTB. A total of 4775 people were randomly selected as controls. Based on 27 weeks of gestation, the area under the curve (AUC) and the accuracy of the RF model were the highest compared with other algorithms (accuracy: 0.816; AUC = 0.885, 95% confidence interval (CI): 0.873–0.897). Meanwhile, there was positive association between the accuracy and AUC of the RF model and gestational age. Age, magnesium, fundal height, serum inorganic phosphorus, mean platelet volume, waist size, total cholesterol, triglycerides, globulins, and total bilirubin were the main influence factors of PTB. Conclusion The results indicated that the prediction model based on the RF algorithm had a potential value to predict preterm birth in the early stage of pregnancy. The important analysis of the RF model suggested that intervention for main factors of PTB in the early stages of pregnancy would reduce the risk of PTB.
Collapse
|
17
|
Use of cervical elastography at 18 to 22 weeks' gestation in the prediction of spontaneous preterm birth. Am J Obstet Gynecol 2021; 225:525.e1-525.e9. [PMID: 34051170 DOI: 10.1016/j.ajog.2021.05.017] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 05/12/2021] [Accepted: 05/14/2021] [Indexed: 01/24/2023]
Abstract
BACKGROUND Accurate identification of the women who will have spontaneous preterm birth continues to be a great challenge. The use of cervical elastography for prediction of preterm birth is promising, but several limitations exist. Newer cervical elastography technology has been developed that may prove useful in evaluation of risk of preterm birth. OBJECTIVE This study aimed to develop standard cervical elastography nomograms for singleton pregnancies at 18 to 22 weeks' gestation using the E-Cervix ultrasound application, assess intraobserver reliability of the E-Cervix elastography parameters, and determine whether these cervical elastography measurements can be used in the prediction of spontaneous preterm birth. STUDY DESIGN This was a prospective cohort study of pregnant women undergoing cervical length screening assessment via transvaginal ultrasound examination at 18 to 22 weeks' gestation. A semiautomatic, cervical elastography application (E-Cervix) was used during the transvaginal examination to calculate 5 quantitative parameters (internal os stiffness, external os stiffness, internal -to -external os stiffness ratio, hardness ratio, and elasticity contrast index) and create a standard nomogram for each one of them. The intraobserver reliability was calculated using Shrout-Fleiss reliability. Cervical elastography parameters were compared between those who delivered preterm (<37 weeks) spontaneously and those who delivered full term. A multivariable logistic regression model was performed to determine the ability of the cervical elastography parameters to predict spontaneous preterm birth. RESULTS A total of 742 women were included, of which 49 (6.6%) had a spontaneous preterm delivery. A standard nomogram was created for each of the cervical elastography parameters from those who had a full-term birth in the index pregnancy (n=693). Intraobserver reliability was good or excellent (intraclass correlation, 0.757-0.887) for each of the cervical elastography parameters except external os stiffness which was poor (intraclass correlation, 0.441). In univariate analysis, none of the cervical elastography parameters were associated with a statistically significant increased risk of spontaneous preterm birth. In a multivariable model adjusting for history of preterm birth, gravidity, ethnicity, cervical cerclage, and vaginal progesterone use, increasing elasticity contrast index was significantly associated with an increased risk of spontaneous preterm birth (odds ratio, 1.15; 95% confidence interval, 1.02-1.30; P=.02). CONCLUSION Cervical elastography parameters are reliably measured and are stable across 18 to 22 weeks' gestation. Based on our findings, the elasticity contrast index was associated with an increased risk of spontaneous preterm birth and may be a useful parameter for future research.
Collapse
|
18
|
Zhou Y, Jin N, Chen Q, Lv M, Jiang Y, Chen Y, Xi F, Yang M, Zhao B, Huang H, Luo Q. Predictive value of cervical length by ultrasound and cervical strain elastography in labor induction at term. J Int Med Res 2021; 49:300060520985338. [PMID: 33557664 PMCID: PMC7876768 DOI: 10.1177/0300060520985338] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
OBJECTIVE This study aimed to examine whether addition of cervical elastographic parameters measured by ElastoScan for the cervix (E-cervix) improves the predictive value of cervical length (CL) in induction of labor at term by dinoprostone. METHODS We conducted a prospective, observational study between January 2020 and June 2020 in term primiparous women (n = 73) who were scheduled for labor induction by a 10-mg dinoprostone vaginal insert. The time intervals from the start of labor induction to regular uterine contractions and to vaginal delivery were calculated as the primary outcomes. We divided subjects into two groups using a threshold of 24 hours. Ultrasound measurements were compared between the two groups and the area under the curve (AUC) of the prediction model was calculated. RESULTS Women who delivered vaginally within 24 hours had a shorter CL and softer cervix than those who delivered after 24 hours. The combination of CL and elastographic parameters increased the AUC to 0.672 compared with CL alone (AUC = 0.637). CONCLUSIONS Measurement by E-cervix is relatively reproducible. Addition of cervical strain elastography slightly improves the predictive performance of CL in vaginal delivery within 24 hours. This technique is a promising ancillary tool for use with ultrasound.
Collapse
Affiliation(s)
- Yimin Zhou
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Neng Jin
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Qinqing Chen
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Min Lv
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Ying Jiang
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Yuan Chen
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Fangfang Xi
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Mengmeng Yang
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Baihui Zhao
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Hefeng Huang
- International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai, China
| | - Qiong Luo
- Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China
| |
Collapse
|
19
|
Vaginal elasticity is significantly decreased in vaginal atrophy: a strain elastography study. ACTA ACUST UNITED AC 2021; 27:1420-1424. [PMID: 33079743 DOI: 10.1097/gme.0000000000001673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Strain elastography is a novel method to assess the elasticity of tissues. We aimed to evaluate the value of vaginal strain elastography in women with vulvovaginal atrophy (VVA). METHODS Women with or without VVA were enrolled in this prospective study. Participants underwent vaginal cytology and vaginal wall elastography. Vaginal Health Index (VHI) was calculated. Based on Vaginal Maturation Value (VMV), participants were divided into atrophic and nonatrophic groups. Elastography parameters of the vaginal walls were measured in nine regions of interest (ROI). Elastography Index (EI) was defined by the average color score of nine ROIs. Groups were compared with unpaired t test or Mann-Whitney U test. Pearson correlation was used to determine the strength of association between EI and selected parameters. Multiple regression was used to evaluate the association between EI and age, VMV, and vaginal atrophy. RESULTS Ten women were diagnosed with VVA, and twenty had no cytological signs of vaginal atrophy (age-range 38-79 y). VHI score was significantly lower in the atrophic group (mean ± SD, 9.4 ± 2.011 vs 16.6 ± 4.22, P < 0.0001). In the atrophic group, EI was significantly lower than in nonatrophic group (mean ± SD, 20 ± 21 vs 47 ± 4, P < 0.01). We found a strong negative correlation between EI and vaginal atrophy (r = -0.706, P < 0.0001; 95% CI: 0.8501 to -0.4639). In the multiple regression model, only atrophy remained statistically significant for the prediction of EI (P = 0.004). CONCLUSIONS Vaginal elasticity is significantly decreased in women with vaginal atrophy, measured by EI. Our results suggest that strain elastography might be useful in the diagnosis of vaginal atrophy.
Collapse
|
20
|
Esin S, Okuyan E, Gunakan E, Zengin HY, Hayran M, Tohma YA. A novel technique for prediction of preterm birth: fetal nasal flow Doppler. J Perinat Med 2021; 49:319-325. [PMID: 33180051 DOI: 10.1515/jpm-2020-0276] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 10/18/2020] [Indexed: 01/20/2023]
Abstract
OBJECTIVES Absence of fetal breathing movements (FBM) has been found to be a good predictor of preterm delivery in symptomatic patients. However, analysis of FBM patterns and Doppler measurement of them for preterm birth prediction have not been performed before. In this study, we aimed to investigate and analyze FBM patterns in symptomatic preterm labor patients by fetal ultrasonography and nasal Doppler. METHODS This was a multicenter, prospective cohort study. Singleton pregnant patients between 24 and 37 gestational weeks diagnosed with preterm labor were included in the study. Patients were evaluated in three groups: no FBM (Group 1), regular FBM (Group 2), irregular FBM (Group3). RESULTS Seventy-three patients were available for the final analysis after exclusion. Preterm delivery rate in 24 h in groups were 91.7, 32.7 and 100%, respectively. The absence of FBM (Group 1) was statistically significant for preterm delivery in for both 24 (91.7 vs. 42.6%, p=0.002) and 48 h (91.7 vs. 49.2%, p=0.006) when compared with fetal breathing positive Group 2 and 3. In fetal nasal Doppler analyses in Group 2, the inspiration/expiration number rate was significantly lower in the patients who delivered in 24 h (0.98±0.2 vs. 1.25±0.57, p=0.015). By using fetal nasal Doppler, combination of absence of FBM or irregular FBM or regular FBM with inspiration number/expiration number (I/E) <1.25 detects 94.6% of patients who will eventually deliver in the first 24 h after admission. CONCLUSIONS Examining FBM patterns and using nasal Doppler may help the clinician to differentiate those who will deliver preterm and may be an invaluable tool for managing preterm labor patients.
Collapse
Affiliation(s)
- Sertac Esin
- Department of Perinatology, Baskent University School of Medicine, Ankara, Turkey
| | | | - Emre Gunakan
- Department of Perinatology, Baskent University School of Medicine, Ankara, Turkey
| | - Hatice Yagmur Zengin
- Department of Biostatistics, Baskent University School of Medicine, Ankara, Turkey
| | - Mutlu Hayran
- Department of Preventive Oncology, Hacettepe University Cancer Institute, Ankara, Turkey
| | - Yusuf Aytac Tohma
- Department of Obstetrics and Gynecology, Baskent University School of Medicine, Ankara, Turkey
| |
Collapse
|
21
|
Cervical Assessment for Predicting Preterm Birth-Cervical Length and Beyond. J Clin Med 2021; 10:jcm10040627. [PMID: 33562187 PMCID: PMC7915684 DOI: 10.3390/jcm10040627] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 01/22/2021] [Accepted: 01/24/2021] [Indexed: 02/07/2023] Open
Abstract
Preterm birth is considered one of the main etiologies of neonatal death, as well as short- and long-term disability worldwide. A number of pathophysiological processes take place in the final unifying factor of cervical modifications that leads to preterm birth. In women at high risk for preterm birth, cervical assessment is commonly used for prediction and further risk stratification. This review outlines the rationale for cervical length screening for preterm birth prediction in different clinical settings within existing and evolving new technologies to assess cervical remodeling.
Collapse
|
22
|
Serum Decorin, Biglycan, and Extracellular Matrix Component Expression in Preterm Birth. Reprod Sci 2020; 28:228-236. [PMID: 32804350 PMCID: PMC7782456 DOI: 10.1007/s43032-020-00251-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 06/17/2020] [Accepted: 06/30/2020] [Indexed: 11/24/2022]
Abstract
Preterm birth is a leading cause of infant morbidity and mortality. Decorin and biglycan are proteoglycans that play key roles in maintaining the connective tissue matrix and tensile strength of human fetal membranes and have been previously linked to PPROM. Extracellular matrix proteins, such as matrix metalloproteinase 2 (MMP-2), matrix metalloproteinase 9 (MMP-9), TIMP metallopeptidase inhibitor 1 (TIMP-1), TIMP metallopeptidase inhibitor 2 (TIMP-2), and collagen VI (COL-6), have also been linked to PPROM and may have utility in a serum-based screening model for this condition. To define the natural course of serum decorin and biglycan expression throughout the duration of healthy pregnancy, to explore patterns of serum decorin and biglycan expression in serum of asymptomatic women who go on to develop spontaneous preterm labor, and to investigate the potential role for matrix metalloproteinases, their inhibitors, and collagen VI in a serum-based screening model to predict PPROM. Serum decorin level decreases less than 1% per week, and serum biglycan decreases by 2.9% per week over the duration of healthy pregnancy. Serum decorin and biglycan concentrations do not differ in spontaneous preterm labor cases compared with those in controls. Mean concentrations of MMP-2, MMP-9, TIMP-1, TIMP-2, and COL-6 do not differ in PPROM cases compared with those in controls. We have demonstrated that serum decorin and biglycan concentrations remain stable throughout the duration of normal pregnancy and are not early indicators of preterm labor, while common MMPs, TIMPs, and collagen VI are not early indicators of PPROM.
Collapse
|