1
|
Liu Q, Shu S, Zhao X, Yu H. Retrospective Analysis of the Correlation between Umbilical Blood Flow Index and Maternal and Fetal Outcomes in Pregnant Women with Gestational Diabetes. Br J Hosp Med (Lond) 2025; 86:1-12. [PMID: 39862042 DOI: 10.12968/hmed.2024.0582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2025]
Abstract
Aims/Background Gestational diabetes mellitus (GDM) is a common complication during pregnancy. This retrospective study investigates the correlation between umbilical blood flow index and maternal-fetal outcomes in pregnant women with GDM, aiming to contribute to evidence-based risk assessment and management strategy in this high-risk obstetric population. Methods This retrospective study recruited 119 pregnant women with GDM who were admitted to the Yichang Central People's Hospital, between January 2022 and January 2024. Based on the umbilical blood flow index, the study participants were divided into a normal umbilical blood flow (UBF) index group (n = 56) and a high UBF index group (n = 63). Colour Doppler ultrasound was used to assess umbilical blood flow, and relevant data on maternal, fetal, and neonatal outcomes were obtained from the hospital's electronic medical records. Results We observed that, compared to the normal UBF index group, the high UBF index group exhibited significantly higher rates of adverse pregnancy outcomes, including the cesarean section (p = 0.022), preterm delivery (p = 0.020), gestational hypertension (p = 0.019), neonatal hypoglycemia (p = 0.015), as well as increased incidence of neonatal complications such as respiratory distress syndrome (p = 0.009), neonatal jaundice (p = 0.022), neonatal intensive care unit (NICU) admission (p = 0.015), lower 5-minute Apgar scores (p = 0.013), and neonatal sepsis (p = 0.005). Furthermore, significant differences were observed in fetal biometric parameters and placental morphology between the two groups (fetal weight: p = 0.003; estimated fetal weight percentile: p = 0.017; femur length: p = 0.018; placental weight: p = 0.019; placental volume: p = 0.021). Additionally, correlation analyses indicated significant associations between umbilical blood flow index and maternal and fetal outcomes (p < 0.05). Conclusion We observed a significant correlation between umbilical blood flow indices and maternal and fetal outcomes in pregnant women with gestational diabetes mellitus, implying its utility as a non-invasive parameter for risk stratification and personalized management in this high-risk obstetric population.
Collapse
Affiliation(s)
- Qiong Liu
- Department of Obstetrics and Gynecology, The First Clinical Medical College of Three Gorges University, Yichang Central People's Hospital, Yichang, Hubei, China
| | - Sinan Shu
- Department of Obstetrics and Gynecology, The First Clinical Medical College of Three Gorges University, Yichang Central People's Hospital, Yichang, Hubei, China
| | - Xiuping Zhao
- Department of Obstetrics and Gynecology, The First Clinical Medical College of Three Gorges University, Yichang Central People's Hospital, Yichang, Hubei, China
| | - Huiling Yu
- Department of Obstetrics and Gynecology, The First Clinical Medical College of Three Gorges University, Yichang Central People's Hospital, Yichang, Hubei, China
| |
Collapse
|
2
|
Shankar N, Kuo L, Krugliak Cleveland N, Galen B, Samel NS, Perez-Sanchez A, Nathanson R, Coss E, Echavarria J, Rubin DT, Soni NJ. Point-of-Care Ultrasound in Gastroenterology and Hepatology. Clin Gastroenterol Hepatol 2025:S1542-3565(25)00019-9. [PMID: 39793722 DOI: 10.1016/j.cgh.2024.09.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Revised: 09/17/2024] [Accepted: 09/30/2024] [Indexed: 01/13/2025]
Abstract
Point-of-care ultrasound (POCUS) is changing the practice of nearly all specialties and is increasingly being incorporated as a bedside tool by more gastroenterologists and hepatologists. POCUS is most often used to answer focused diagnostic questions, supplement the traditional physical examination, and guide performance of invasive bedside procedures. This review describes several common POCUS applications used in gastroenterology and hepatology, as well as some novel applications that warrant further investigation.
Collapse
Affiliation(s)
- Nagasri Shankar
- Division of Gastroenterology and Hepatology, Joe R. Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas
| | - Lily Kuo
- Division of Gastroenterology and Hepatology, Joe R. Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas
| | | | - Benjamin Galen
- Division of Hospital Medicine, Department of Medicine, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, New York
| | - Nicholas S Samel
- Department of Medicine, Albert Einstein College of Medicine, Bronx, New York
| | - Ariadna Perez-Sanchez
- Division of Hospital Medicine, Joe R. Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas
| | - Robert Nathanson
- Division of Hospital Medicine, Joe R. Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas; Medicine Service, South Texas Veterans Health Care System, San Antonio, Texas
| | - Elizabeth Coss
- Medicine Service, South Texas Veterans Health Care System, San Antonio, Texas
| | - Juan Echavarria
- Division of Gastroenterology and Hepatology, Joe R. Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas
| | - David T Rubin
- University of Chicago Medicine IBD Center, Chicago, Illinois
| | - Nilam J Soni
- Division of Hospital Medicine, Joe R. Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas; Medicine Service, South Texas Veterans Health Care System, San Antonio, Texas; Division of Pulmonary Diseases and Critical Care Medicine, Joe R. and Teresa Lozano Long School of Medicine, University of Texas Health San Antonio, San Antonio, Texas.
| |
Collapse
|
3
|
Cheng W, Wang KY, Li WQ, Li Y, Li XY, Ju S. CT-based nomogram predicts esophageal gastric variceal bleeding in noncirrhotic portal hypertension caused by hepatic schistosomiasis. BMC Med Inform Decis Mak 2025; 25:8. [PMID: 39773170 PMCID: PMC11708042 DOI: 10.1186/s12911-024-02777-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 11/19/2024] [Indexed: 01/11/2025] Open
Abstract
BACKGROUND To construct a nomogram combining CT varices vein evaluation and clinical laboratory tests for predicting the risk of esophageal gastric variceal bleeding (EGVB) in patients with noncirrhotic portal hypertension (NCPH). METHODS A total of 315 NCPH patients with non-EGVB and EGVB were retrospectively enrolled and randomly divided into training and testing cohorts. Thirteen collateral vessels were identified and evaluated after CT portal vein system reconstruction. Multivariate binary logistic regression analysis was used to choose CT images and clinical predictors of EGVB. The varices score of each patient was calculated. A nomogram was built by combining the varices score with the selected clinical predictors of EGVB. The receiver operating characteristic (ROC) curve was used to evaluate the predictive performance of the nomogram. RESULTS Platelet count and prothrombin time were selected as clinical predictors; the esophageal vein, gastroepiploic vein and omental vein were selected as CT image predictors for predicting EGVB. A reduced platelet count, prolonged prothrombin time, severe esophageal and gastroepiploic vein tortuosity and less omental vein tortuosity were predictors of EGVB in NCPH patients. The specificity, sensitivity, negative predictive value, positive predictive value and AUC of the ROC of the nomogram were 0.82, 0.81, 0.89, 0.70, and 0.88 (95% CI: 0.84-0.93) in the training cohort and 0.87, 0.86, 0.88, 0.84, and 0.91 (95% CI: 0.84-0.97) in the testing cohort, respectively. CONCLUSIONS The nomogram combining CT images and clinical predictors could be useful to individualize and predict the risk of EGVB in NCPH patients. CLINICAL RELEVANCE STATEMENT Results showed that the nomogram combining CT-evaluated collateral vessels (varices score) and clinical laboratory tests could be used to realize personalized prediction of first-time EGVB in NCPH patients.
Collapse
Affiliation(s)
- Wei Cheng
- Department of Radiology, Jinshan Hospital, Fudan University, Shanghai, 201508, China
| | - Ke-Ying Wang
- Department of Radiology, Jinshan Hospital, Fudan University, Shanghai, 201508, China
| | - Wen-Qiang Li
- Department of Vascular and Wound Center, Jinshan Hospital, Fudan University, Shanghai, 201508, China
| | - Yao Li
- Department of Vascular and Wound Center, Jinshan Hospital, Fudan University, Shanghai, 201508, China
| | - Xiao-Yan Li
- Department of Vascular and Wound Center, Jinshan Hospital, Fudan University, Shanghai, 201508, China
| | - Shuai Ju
- Department of Vascular and Wound Center, Jinshan Hospital, Fudan University, Shanghai, 201508, China.
| |
Collapse
|
4
|
Zou X, Liu L, Tan F, Tang H, Hu D, Li Z, Wang Q, Shen Y. Non-contrast-enhanced MR angiography of left gastric vein in patients with gastroesophageal varices: morphology and blood supply analysis. Eur Radiol 2024; 34:4686-4696. [PMID: 38133674 DOI: 10.1007/s00330-023-10497-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 09/07/2023] [Accepted: 10/29/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVES To investigate the feasibility of non-contrast-enhanced MR angiography (NCE-MRA) in evaluating the morphology and blood supply of left gastric vein (LGV) in patients with gastroesophageal varices. METHODS Between March 2021 and October 2022, patients with gastroesophageal varices and who underwent NCE-MRA were retrospectively reviewed. In order to evaluate the blood supply of LGV, superior mesenteric vein (SMV) and splenic vein (SV) were visualized separately by using inflow-sensitive inversion recovery sequence. Two radiologists independently assessed the image quality, determined the origination and the blood supply of LGV, and measured the diameter of LGV. The origination and diameter of LGV were compared between NCE-MRA and contrast-enhanced CT. Differences in blood supply were compared between LGVs with different originations. RESULTS A total of 53 patients were enrolled in this study and the image quality was categorized as good or excellent in 52 patients. No significant differences were observed in visualizing the origination and the diameter of LGV between NCE-MRA and contrast-enhanced CT (p > .05). The blood supply of LGV was related to its origination (p < .001). Most LGVs with SV origination were supplied by SV. If LGV was originated from the portal vein (PV), about 70% of them were supplied by both SV and SMV. Compared with LGVs with SV origination, LGVs with PV origination showed more chance to receive blood from SMV (p < .001). CONCLUSION Non-contrast-enhanced MR angiography appears to be a reliable technique in evaluating the morphology and blood supply of LGV in patients with gastroesophageal varices. CLINICAL RELEVANCE STATEMENT Non-contrast-enhanced MR angiography provides valuable information for the management of gastroesophageal varices. Especially, it benefits patients with renal insufficiency. KEY POINTS • Non-contrast-enhanced MR angiography using inflow-sensitive inversion recovery technique can be used for evaluating not only morphology as CT but also blood supply of left gastric vein. • The blood supply of left gastric vein is related to its origination and left gastric vein with portal vein origination shows more chance to receive blood from superior mesenteric vein.
Collapse
Affiliation(s)
- Xianlun Zou
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China
| | - Lisi Liu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China
| | - Fangqin Tan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China
| | - Hao Tang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China
| | - Daoyu Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China
| | - Zhen Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China
| | - Qiuxia Wang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China.
| | - Yaqi Shen
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei, China.
| |
Collapse
|
5
|
Shi B, Han Z, Zhang W, Li W. The clinical value of color ultrasound screening for fetal cardiovascular abnormalities during the second trimester: A systematic review and meta-analysis. Medicine (Baltimore) 2023; 102:e34211. [PMID: 37443473 PMCID: PMC10344501 DOI: 10.1097/md.0000000000034211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 06/14/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND This meta-analysis aimed to investigate the diagnostic value of color ultrasound screening for fetal cardiovascular abnormalities during the second trimester in China. METHODS A literature search was conducted to evaluate the clinical value of color ultrasound screening for fetal cardiovascular abnormalities during the second trimester using English and Chinese databases. Numerical values for sensitivity and specificity were obtained from false-negative, false-positive, true-negative, and true-positive rates, presented alongside graphical representations with boxes marking the values and horizontal lines showing the confidence intervals. Summary receiver operating characteristic (SROC) curves were applied to assess the performance of the diagnostic tests. Data were processed using Review Manager 5.3. RESULTS Four studies (151 patients with fetal cardiovascular abnormalities and 3397 undiagnosed controls) met our evaluation criteria. The sensitivity was 0.91 and 0.96, respectively, and the specificity was 1.00. The Area Under the Curve (AUC) from the SROC curves was >90%; therefore, it was classified as excellent. Furthermore, there were 6 types of fetal cardiovascular abnormalities, and the pooled screening rate of atrioventricular septal defects was the highest. CONCLUSION Our meta-analysis showed that the use of color ultrasound during the second trimester can be an excellent diagnostic tool for fetal cardiovascular abnormalities.
Collapse
Affiliation(s)
- Bingye Shi
- Color Ultrasound Room, Affiliated Hospital of Hebei University, Baoding, China
| | - Zhe Han
- Department of Cardiac Surgery, Affiliated Hospital of Hebei University, Baoding, China
| | - Wei Zhang
- Medical Engineering Center, Affiliated Hospital of Hebei University, Baoding, China
| | - Wenxiu Li
- Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
6
|
Pepin KM, Welle CL, Guglielmo FF, Dillman JR, Venkatesh SK. Magnetic resonance elastography of the liver: everything you need to know to get started. Abdom Radiol (NY) 2022; 47:94-114. [PMID: 34725719 PMCID: PMC9538666 DOI: 10.1007/s00261-021-03324-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 10/17/2021] [Accepted: 10/18/2021] [Indexed: 12/17/2022]
Abstract
Magnetic resonance elastography (MRE) of the liver has emerged as the non-invasive standard for the evaluation of liver fibrosis in chronic liver diseases (CLDs). The utility of MRE in the evaluation of different CLD in both adults and children has been demonstrated in several studies, and MRE has been recommended by several clinical societies. Consequently, the clinical indications for evaluation of CLD with MRE have increased, and MRE is currently used as an add-on test during routine liver MRI studies or as a standalone test. To meet the increasing clinical demand, MRE is being installed in many academic and private practice imaging centers. There is a need for a comprehensive practical guide to help these practices to deliver high-quality liver MRE studies as well as troubleshoot the common issues with MRE to ensure smooth running of the service. This comprehensive clinical practice review summarizes the indications and provides an overview on why to use MRE, technical requirements, system set-up, patient preparation, acquiring the data, and interpretation.
Collapse
Affiliation(s)
- Kay M Pepin
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, USA
- Resoundant Inc, Rochester, MN, USA
| | - Christopher L Welle
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, USA
| | | | - Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | | |
Collapse
|
7
|
Florea M, Serban T, Tirpe GR, Tirpe A, Lupsor-Platon M. Noninvasive Assessment of Hepatitis C Virus Infected Patients Using Vibration-Controlled Transient Elastography. J Clin Med 2021; 10:jcm10122575. [PMID: 34200885 PMCID: PMC8230562 DOI: 10.3390/jcm10122575] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/06/2021] [Accepted: 06/08/2021] [Indexed: 02/08/2023] Open
Abstract
Chronic infection with hepatitis C virus (HCV) is one of the leading causes of cirrhosis and hepatocellular carcinoma (HCC). Surveillance of these patients is an essential strategy in the prevention chain, including in the pre/post-antiviral treatment states. Ultrasound elastography techniques are emerging as key methods in the assessment of liver diseases, with a number of advantages such as their rapid, noninvasive, and cost-effective characters. The present paper critically reviews the performance of vibration-controlled transient elastography (VCTE) in the assessment of HCV patients. VCTE measures liver stiffness (LS) and the ultrasonic attenuation through the embedded controlled attenuation parameter (CAP), providing the clinician with a tool for assessing fibrosis, cirrhosis, and steatosis in a noninvasive manner. Moreover, standardized LS values enable proper staging of the underlying fibrosis, leading to an accurate identification of a subset of HCV patients that present a high risk for complications. In addition, VCTE is a valuable technique in evaluating liver fibrosis prior to HCV therapy. However, its applicability in monitoring fibrosis regression after HCV eradication is currently limited and further studies should focus on extending the boundaries of VCTE in this context. From a different perspective, VCTE may be effective in identifying clinically significant portal hypertension (CSPH). An emerging prospect of clinical significance that warrants further study is the identification of esophageal varices. Our opinion is that the advantages of VCTE currently outweigh those of other surveillance methods.
Collapse
Affiliation(s)
- Mira Florea
- Community Medicine Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
| | - Teodora Serban
- Medical Imaging Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
| | - George Razvan Tirpe
- Department of Radiology and Medical Imaging, County Emergency Hospital Cluj-Napoca, 3-5 Clinicilor Street, 400000 Cluj-Napoca, Romania;
| | - Alexandru Tirpe
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 23 Marinescu Street, 400337 Cluj-Napoca, Romania;
| | - Monica Lupsor-Platon
- Medical Imaging Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
- Medical Imaging Department, Regional Institute of Gastroenterology and Hepatology, 400162 Cluj-Napoca, Romania
- Correspondence:
| |
Collapse
|