1
|
Wesdemiotis C, Williams-Pavlantos KN, Keating AR, McGee AS, Bochenek C. Mass spectrometry of polymers: A tutorial review. MASS SPECTROMETRY REVIEWS 2024; 43:427-476. [PMID: 37070280 DOI: 10.1002/mas.21844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 03/03/2023] [Accepted: 03/17/2023] [Indexed: 06/19/2023]
Abstract
Ever since the inception of synthetic polymeric materials in the late 19th century, the number of studies on polymers as well as the complexity of their structures have only increased. The development and commercialization of new polymers with properties fine-tuned for specific technological, environmental, consumer, or biomedical applications requires powerful analytical techniques that permit the in-depth characterization of these materials. One such method with the ability to provide chemical composition and structure information with high sensitivity, selectivity, specificity, and speed is mass spectrometry (MS). This tutorial review presents and exemplifies the various MS techniques available for the elucidation of specific structural features in a synthetic polymer, including compositional complexity, primary structure, architecture, topology, and surface properties. Key to every MS analysis is sample conversion to gas-phase ions. This review describes the fundamentals of the most suitable ionization methods for synthetic materials and provides relevant sample preparation protocols. Most importantly, structural characterizations via one-step as well as hyphenated or multidimensional approaches are introduced and demonstrated with specific applications, including surface sensitive and imaging techniques. The aim of this tutorial review is to illustrate the capabilities of MS for the characterization of large, complex polymers and emphasize its potential as a powerful compositional and structural elucidation tool in polymer chemistry.
Collapse
Affiliation(s)
| | | | - Addie R Keating
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| | - Andrew S McGee
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| | - Calum Bochenek
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| |
Collapse
|
2
|
Sun A'B, Li S, Kou X. Applications of MALDI-TOF-MS in structural characterization of synthetic polymers. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:868-883. [PMID: 36745057 DOI: 10.1039/d2ay01583h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
In recent years, matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been utilized to rapidly and precisely characterize the detailed molecular structures of synthetic polymers. This review summarizes recent progress regarding MALDI-TOF-MS for the characterization of synthetic polymers with a focus on specific important experimental aspects including sample preparation, the choice of matrix, the effects of cationizing agents and solvents, data processing and various applications. Finally, the recent trend of MALDI-TOF-MS development is discussed. We hope this review will be instructive for graduate students and junior users who need to use MALDI-TOF-MS as a necessary characterization technique for new synthetic polymers.
Collapse
Affiliation(s)
- A 'Bin Sun
- Shandong Provincial Education Department, Key Laboratory of Biobased Polymer Materials, College of Polymer Science and Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Siting Li
- Shandong Provincial Education Department, Key Laboratory of Biobased Polymer Materials, College of Polymer Science and Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Xinhui Kou
- Shandong Provincial Education Department, Key Laboratory of Biobased Polymer Materials, College of Polymer Science and Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
- Analyses and Testing Center, Qingdao University of Science and Technology, Qingdao 266042, China.
| |
Collapse
|
3
|
Novel Short PEG Chain-Substituted Porphyrins: Synthesis, Photochemistry, and In Vitro Photodynamic Activity against Cancer Cells. Int J Mol Sci 2022; 23:ijms231710029. [PMID: 36077451 PMCID: PMC9456001 DOI: 10.3390/ijms231710029] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/15/2022] [Accepted: 08/26/2022] [Indexed: 11/16/2022] Open
Abstract
This work presents the synthesis and characterization of metal-free, zinc (II), and cobalt (II) porphyrins substituted with short PEG chains. The synthesized compounds were characterized by UV-Vis, 1H and 13C NMR spectroscopy, and MALDI-TOF mass spectrometry. The origin of the absorption bands for tested compounds in the UV-Vis range was determined using a computational model based on the electron density functional theory (DFT) and its time-dependent variant (TD-DFT). The photosensitizing activity was evaluated by measuring the ability to generate singlet oxygen (ΦΔ), which reached values up to 0.54. The photodynamic activity was tested using bladder (5637), prostate (LNCaP), and melanoma (A375) cancer cell lines. In vitro experiments clearly showed the structure-activity relationship regarding types of substituents, their positions in the phenyl ring, and the variety of central metal ions on the porphyrin core. Notably, the metal-free derivative 3 and its zinc derivative 6 exerted strong cytotoxic activity toward 5637 cells, with IC50 values of 8 and 15 nM, respectively. None of the tested compounds induced a cytotoxic effect without irradiation. In conclusion, these results highlight the potential value of the tested compounds for PDT application.
Collapse
|
4
|
Wierzchowski M, Ziental D, Łażewski D, Korzanski A, Gielara-Korzanska A, Tykarska E, Dlugaszewska J, Sobotta L. New Metallophthalocyanines Bearing 2-Methylimidazole Moieties-Potential Photosensitizers against Staphylococcus aureus. Int J Mol Sci 2022; 23:ijms23115910. [PMID: 35682587 PMCID: PMC9180345 DOI: 10.3390/ijms23115910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 05/17/2022] [Accepted: 05/21/2022] [Indexed: 02/04/2023] Open
Abstract
Newly developed tetra- and octasubstituted methimazole-phthalocyanine conjugates as potential photosensitizers have been obtained. Synthesized intermediates and final products were characterized by the MALD-TOF technique and various NMR techniques, including 2D methods. Single-crystal X-ray diffraction was used to determine the crystal structures of dinitriles. The studied phthalocyanines revealed two typical absorption bands—the Soret band and the Q band. The most intense fluorescence was observed for octasubstituted magnesium(II) phthalocyanine in DMF (ΦFL = 0.022). The best singlet oxygen generators were octasubstituted magnesium(II) and zinc(II) phthalocyanines (Φ∆ 0.56 and 0.81, respectively). The studied compounds presented quantum yields of photodegradation at the level between 10−5 and 10−6. Due to their low solubility in a water environment, the liposomal formulations were prepared. Within the studied group, octasubstituted zinc(II) phthalocyanine at the concentration of 100 µM activated with red light showed the highest antibacterial activity against S. aureus equal to a 5.68 log reduction of bacterial growth.
Collapse
Affiliation(s)
- Marcin Wierzchowski
- Chair and Department of Chemical Technology of Drugs, Poznan University of Medical Sciences, Grunwaldzka 6, 60-780 Poznan, Poland; (M.W.); (D.Ł.); (A.G.-K.); (E.T.)
| | - Daniel Ziental
- Chair and Department of Inorganic and Analytical Chemistry, Poznan University of Medical Sciences, Rokietnicka 3, 60-806 Poznan, Poland;
| | - Dawid Łażewski
- Chair and Department of Chemical Technology of Drugs, Poznan University of Medical Sciences, Grunwaldzka 6, 60-780 Poznan, Poland; (M.W.); (D.Ł.); (A.G.-K.); (E.T.)
| | - Artur Korzanski
- Department of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznanskiego 8, 61-614 Poznan, Poland;
| | - Agnieszka Gielara-Korzanska
- Chair and Department of Chemical Technology of Drugs, Poznan University of Medical Sciences, Grunwaldzka 6, 60-780 Poznan, Poland; (M.W.); (D.Ł.); (A.G.-K.); (E.T.)
| | - Ewa Tykarska
- Chair and Department of Chemical Technology of Drugs, Poznan University of Medical Sciences, Grunwaldzka 6, 60-780 Poznan, Poland; (M.W.); (D.Ł.); (A.G.-K.); (E.T.)
| | - Jolanta Dlugaszewska
- Chair and Department of Genetics and Pharmaceutical Microbiology, Poznan University of Medical Sciences, Rokietnicka 3, 60-806 Poznan, Poland;
| | - Lukasz Sobotta
- Chair and Department of Inorganic and Analytical Chemistry, Poznan University of Medical Sciences, Rokietnicka 3, 60-806 Poznan, Poland;
- Correspondence:
| |
Collapse
|
5
|
Schneider P, Verloh F, Dürr M. Cluster-Induced Desorption/Ionization of Polystyrene: Desorption Mechanism and Effect of Polymer Chain Length on Desorption Probability. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:832-839. [PMID: 35426303 DOI: 10.1021/jasms.2c00021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Soft cluster-induced desorption/ionization of polystyrene oligomers was investigated with respect to application in mass spectrometry. Clear peak progressions corresponding to intact polystyrene molecules were observed in the mass spectra, and no fragmentation was detected; efficient desorption was deduced from quartz crystal microbalance measurements. Molecular dynamics (MD) simulations of the process revealed that even in the case of the nonpolar polystyrene molecules cluster-induced desorption proceeds via dissolvation in the polar clusters. Experimentally, a significantly lower desorption efficiency was observed for polystyrene molecules with larger chain length. Taking into account MD simulations and further experiments with mixed samples consisting of long- and short-chain polystyrene oligomers, the reduced desorption efficiency for longer chain polystyrene molecules was attributed to a stronger entanglement of the larger polystyrene molecules.
Collapse
Affiliation(s)
- Pascal Schneider
- Institut für Angewandte Physik and Zentrum für Materialforschung, Justus-Liebig-Universität Giessen, Heinrich-Buff-Ring 16, D-35392 Giessen, Germany
| | - Felix Verloh
- Institut für Angewandte Physik and Zentrum für Materialforschung, Justus-Liebig-Universität Giessen, Heinrich-Buff-Ring 16, D-35392 Giessen, Germany
| | - Michael Dürr
- Institut für Angewandte Physik and Zentrum für Materialforschung, Justus-Liebig-Universität Giessen, Heinrich-Buff-Ring 16, D-35392 Giessen, Germany
| |
Collapse
|
6
|
Morgan TE, Floyd TG, Marzullo BP, Wootton CA, Barrow MP, Bristow AWT, Perrier S, O'Connor PB. Stochasticity of poly(2-oxazoline) oligomer hydrolysis determined by tandem mass spectrometry. Polym Chem 2022; 13:4162-4169. [PMID: 35923808 PMCID: PMC9294869 DOI: 10.1039/d2py00437b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/01/2022] [Indexed: 11/30/2022]
Abstract
Understanding modification of synthetic polymer structures is necessary for their accurate synthesis and potential applications. In this contribution, a series of partially hydrolyzed poly(2-oxazoline) species were produced forming poly[(2-polyoxazoline)-co-(ethylenimine)] (P(EtOx-co-EI)) copolymers; EI being the hydrolyzed product of Ox. Bulk mass spectrometry (MS) measurements accurately measured the EI content. Tandem mass spectrometry analysis of the EI content in the copolymer samples determined the distribution of each monomer within the copolymer and corresponded to a theoretically modelled random distribution. The EI distribution across the polymers was shown to be effected by the choice of terminus, with a permanent hydrolysis event observed at an OH terminus. A neighbouring group effect wasn't observed at the polymer length analysed (approximately 25-mer species), suggesting that previously observed neighbouring group effects require a larger polymer chain. Although clearly useful for random polymer distribution this approach may be applied to many systems containing non-specific modifications to determine if they are directed or random locations across peptides, proteins, polymers, and nucleic acids. Tandem mass spectrometry can be used to better understand modification sites of synthetic polymer structures providing more complete chemical knowledge which is necessary for their accurate synthesis and potential applications.![]()
Collapse
Affiliation(s)
- Tomos E Morgan
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Thomas G Floyd
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Bryan P Marzullo
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | | | - Mark P Barrow
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Anthony W T Bristow
- Chemical Development, Pharmaceutical Technology and Development, Operations, AstraZeneca Charter Way Macclesfield SK102NA UK
| | - Sébastien Perrier
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
- Warwick Medical School, University of Warwick Coventry CV4 7AL UK
- Faculty of Pharmaceutical Sciences, Monash University 381 Royal Parade Parkville VIC 3052 Australia
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| |
Collapse
|
7
|
Zaikin VG, Borisov RS. Mass Spectrometry as a Crucial Analytical Basis for Omics Sciences. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [PMCID: PMC8693159 DOI: 10.1134/s1061934821140094] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
This review is devoted to the consideration of mass spectrometric platforms as applied to omics sciences. The most significant attention is paid to omics related to life sciences (genomics, proteomics, meta-bolomics, lipidomics, glycomics, plantomics, etc.). Mass spectrometric approaches to solving the problems of petroleomics, polymeromics, foodomics, humeomics, and exosomics, related to inorganic sciences, are also discussed. The review comparatively presents the advantages of various principles of separation and mass spectral techniques, complementary derivatization, used to obtain large arrays of various structural and quantitative information in the mentioned omics sciences.
Collapse
Affiliation(s)
- V. G. Zaikin
- Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, 119991 Moscow, Russia
| | - R. S. Borisov
- Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, 119991 Moscow, Russia
- RUDN University, 117198 Moscow, Russia
- Core Facility Center “Arktika,” Northern (Arctic) Federal University, 163002 Arkhangelsk, Russia
| |
Collapse
|
8
|
Morgan TE, Kerr A, Wootton CA, Barrow MP, Bristow AW, Perrier S, O’Connor PB. Electron Capture Dissociation of Trithiocarbonate-Terminated Acrylamide Homo- and Copolymers: A Terminus-Directed Mechanism? Anal Chem 2020; 92:12852-12859. [DOI: 10.1021/acs.analchem.0c01224] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Tomos E. Morgan
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| | - Andrew Kerr
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| | | | - Mark P. Barrow
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| | - Anthony W.T. Bristow
- Chemical Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Macclesfield, Cheshire SK10 2NA, U.K
| | - Sébastien Perrier
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
- Warwick Medical School, University of Warwick, Coventry CV4 7AL, U.K
- Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Peter B. O’Connor
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| |
Collapse
|
9
|
Yang Y, Gao D, Qian R, Jiang Y. Polydopamine-Modified TS-1 Zeolite Framework Nanoparticles as a Matrix for the Analysis of Small Molecules by MALDI-TOF MS. ACS OMEGA 2020; 5:19952-19959. [PMID: 32832749 PMCID: PMC7439277 DOI: 10.1021/acsomega.0c00992] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 06/23/2020] [Indexed: 06/11/2023]
Abstract
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) using conventional organic matrices for detection of small molecules has some limitations, such as heterogeneous analyte/matrix co-crystals, as well as interference of matrices in the low-molecular-weight range. In this work, a zeolite framework nanomaterial, TS-1, was applied as a MALDI matrix for the analysis of small molecules by MALDI-MS for the first time. To improve the signal intensity and reproducibility, TS-1 was modified with polydopamine (TS-1@PDA). Using TS-1@PDA as a matrix, organic substances in the low-molecular-weight region such as amino acids, nucleosides, peptides, oligosaccharides, and fatty acids can be detected by MALDI-MS in positive ion mode. Compared with traditional organic matrices like 2,5-dihydroxybenzoic acid (2,5-DHB) and α-cyano-4-hydroxycinnamic acid (CHCA), TS-1@PDA has the advantages including the formation of uniform sample spots, small background interference at low molecular weight, and better salt tolerance. Furthermore, this matrix was employed for the analysis of endogenous glucose in urine samples, and the level of glucose was quantified with a linear range of 0-10 mM (R 2 > 0.98). The results demonstrated that TS-1@PDA has the potential to be used as an effective MALDI matrix for the analysis of small molecules in biological samples with excellent reproducibility and moderate sensitivity.
Collapse
Affiliation(s)
- Yumeng Yang
- State
Key Laboratory of Chemical Oncogenomics, Tsinghua Shenzhen International
Graduate School, Tsinghua University, Shenzhen 518055, China
- Key
Laboratory of Metabolomics at Shenzhen, Shenzhen 518055, China
| | - Dan Gao
- State
Key Laboratory of Chemical Oncogenomics, Tsinghua Shenzhen International
Graduate School, Tsinghua University, Shenzhen 518055, China
- Key
Laboratory of Metabolomics at Shenzhen, Shenzhen 518055, China
| | - Rui Qian
- State
Key Laboratory of Chemical Oncogenomics, Tsinghua Shenzhen International
Graduate School, Tsinghua University, Shenzhen 518055, China
- Key
Laboratory of Metabolomics at Shenzhen, Shenzhen 518055, China
| | - Yuyang Jiang
- State
Key Laboratory of Chemical Oncogenomics, Tsinghua Shenzhen International
Graduate School, Tsinghua University, Shenzhen 518055, China
- School
of Pharmaceutical Sciences, Tsinghua University, Beijing 100084, China
| |
Collapse
|