1
|
Fukuda A, Lin PP, Ichikawa N, Matsubara K. Determination of geometric information and radiation field overlaps on the skin in percutaneous coronary interventions with computer-aided design-based X-ray beam modeling. J Appl Clin Med Phys 2021; 22:140-148. [PMID: 34699677 PMCID: PMC8664137 DOI: 10.1002/acm2.13457] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 09/18/2021] [Accepted: 10/05/2021] [Indexed: 11/12/2022] Open
Abstract
PURPOSE This study aimed to develop a method for the determination of the source-to-surface distance (SSD), the X-ray beam area in a plane perpendicular to the beam axis at the entrance skin surface (Ap ), and the X-ray beam area on the actual skin surface (As ) during percutaneous coronary intervention (PCI). MATERIALS AND METHODS Male and female anthropomorphic phantoms were scanned on a computed tomography scanner, and the data were transferred to a commercially available computer-aided design (CAD) software. A cardiovascular angiography system with a 200 × 200 mm flat-panel detector with a field-of-view of 175 × 175 mm was modeled with the CAD software. Both phantoms were independently placed on 40 mm thick pads, and the examination tabletop at the patient entrance reference point. Upon panning, the heart center was aligned to the central beam axis. The SSD, Ap , and As were determined with the measurement tool and Boolean intersection operations at 10 gantry angulations. RESULTS The means and standard deviations of the SSD, Ap , and As for the male and female phantoms were 573 ± 15 and 580 ± 15 mm, 8799 ± 1009 and 9661 ± 1152 mm2 , 10495 ± 602 and 11913 ± 600 mm2 , respectively. The number of As overlaps for the male and female phantoms were 15/45 and 21/45 view combinations, respectively. CONCLUSIONS CAD-based X-ray beam modeling is useful for the determination of the SSD, Ap , and As . Furthermore, the knowledge of the As distribution helps to reduce the As overlap in PCI.
Collapse
Affiliation(s)
- Atsushi Fukuda
- Department of Radiological Sciences, School of Health SciencesFukushima Medical UniversityFukushimaJapan
| | - Pei‐Jan P. Lin
- Department of RadiologyVirginia Commonwealth University Medical CenterRichmondVirginiaUSA
| | - Nao Ichikawa
- Department of Radiological Technology, Faculty of Health ScienceKobe Tokiwa UniversityHyogoJapan
| | - Kosuke Matsubara
- Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health SciencesKanazawa UniversityIshikawaJapan
| |
Collapse
|
2
|
Fum WKS, Wong JHD, Tan LK. Monte Carlo-based patient internal dosimetry in fluoroscopy-guided interventional procedures: A review. Phys Med 2021; 84:228-240. [PMID: 33849785 DOI: 10.1016/j.ejmp.2021.03.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 02/18/2021] [Accepted: 03/03/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE This systematic review aims to understand the dose estimation approaches and their major challenges. Specifically, we focused on state-of-the-art Monte Carlo (MC) methods in fluoroscopy-guided interventional procedures. METHODS All relevant studies were identified through keyword searches in electronic databases from inception until September 2020. The searched publications were reviewed, categorised and analysed based on their respective methodology. RESULTS Hundred and one publications were identified which utilised existing MC-based applications/programs or customised MC simulations. Two outstanding challenges were identified that contribute to uncertainties in the virtual simulation reconstruction. The first challenge involves the use of anatomical models to represent individuals. Currently, phantom libraries best balance the needs of clinical practicality with those of specificity. However, mismatches of anatomical variations including body size and organ shape can create significant discrepancies in dose estimations. The second challenge is that the exact positioning of the patient relative to the beam is generally unknown. Most dose prediction models assume the patient is located centrally on the examination couch, which can lead to significant errors. CONCLUSION The continuing rise of computing power suggests a near future where MC methods become practical for routine clinical dosimetry. Dynamic, deformable phantoms help to improve patient specificity, but at present are only limited to adjustment of gross body volume. Dynamic internal organ displacement or reshaping is likely the next logical frontier. Image-based alignment is probably the most promising solution to enable this, but it must be automated to be clinically practical.
Collapse
Affiliation(s)
- Wilbur K S Fum
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia; Division of Radiological Sciences, Singapore General Hospital, Outram Rd, Singapore 169608, Singapore.
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Li Kuo Tan
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia.
| |
Collapse
|
3
|
Colombo P, Felisi M, Riga S, Torresin A. On skin dose estimation software in interventional radiology. Phys Med 2021; 81:182-184. [DOI: 10.1016/j.ejmp.2020.12.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 12/18/2020] [Accepted: 12/20/2020] [Indexed: 12/29/2022] Open
|
4
|
Skin dose assessment in interventional radiology. Phys Med 2021; 81:170-172. [DOI: 10.1016/j.ejmp.2020.12.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 12/17/2020] [Accepted: 12/18/2020] [Indexed: 02/05/2023] Open
|
5
|
Malchair F, Dabin J, Deleu M, Merce MS, Bjelac OC, Gallagher A, Maccia C. Review of skin dose calculation software in interventional cardiology. Phys Med 2020; 80:75-83. [DOI: 10.1016/j.ejmp.2020.09.023] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 09/16/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022] Open
|
6
|
Swartz HM, Flood AB, Singh VK, Swarts SG. Scientific and Logistical Considerations When Screening for Radiation Risks by Using Biodosimetry Based on Biological Effects of Radiation Rather than Dose: The Need for Prior Measurements of Homogeneity and Distribution of Dose. HEALTH PHYSICS 2020; 119:72-82. [PMID: 32175928 PMCID: PMC7269859 DOI: 10.1097/hp.0000000000001244] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
An effective medical response to a large-scale radiation event requires prompt and effective initial triage so that appropriate care can be provided to individuals with significant risk for severe acute radiation injury. Arguably, it would be advantageous to use injury rather than radiation dose for the initial assessment; i.e., use bioassays of biological damage. Such assays would be based on changes in intrinsic biological response elements; e.g., up- or down-regulation of genes, proteins, metabolites, blood cell counts, chromosomal aberrations, micronuclei, micro-RNA, cytokines, or transcriptomes. Using a framework to evaluate the feasibility of biodosimetry for triaging up to a million people in less than a week following a major radiation event, Part 1 analyzes the logistical feasibility and clinical needs for ensuring that biomarkers of organ-specific injury could be effectively used in this context. We conclude that the decision to use biomarkers of organ-specific injury would greatly benefit by first having independent knowledge of whether the person's exposure was heterogeneous and, if so, what was the dose distribution (to determine which organs were exposed to high doses). In Part 2, we describe how these two essential needs for prior information (heterogeneity and dose distribution) could be obtained by using in vivo nail dosimetry. This novel physical biodosimetry method can also meet the needs for initial triage, providing non-invasive, point-of-care measurements made by non-experts with immediate dose estimates for four separate anatomical sites. Additionally, it uniquely provides immediate information as to whether the exposure was homogeneous and, if not, it can estimate the dose distribution. We conclude that combining the capability of methods such as in vivo EPR nail dosimetry with bioassays to predict organ-specific damage would allow effective use of medical resources to save lives.
Collapse
Affiliation(s)
- Harold M. Swartz
- Dept of Radiology, Geisel School of Medicine at Dartmouth College, Hanover, NH USA
- Dept of Medicine/Radiation Oncology, Geisel School of Medicine at Dartmouth College, Hanover, NH USA
| | - Ann Barry Flood
- Dept of Radiology, Geisel School of Medicine at Dartmouth College, Hanover, NH USA
| | - Vijay K. Singh
- Dept. Pharmacology & Molecular Therapeutics, F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
- Armed Forces Radiobiology Research Institute, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Steven G. Swarts
- Dept of Radiation Oncology, University of Florida, Gainesville, FL, USA
| |
Collapse
|
7
|
Colombo PE, Rottoli F, Felisi M, De Mattia C, Riga S, Sutto M, Dillion C, Massey S, Torresin A. Validation of a dose tracking software for skin dose map calculation in interventional radiology. Phys Med 2020; 72:122-132. [DOI: 10.1016/j.ejmp.2020.03.008] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 03/02/2020] [Accepted: 03/03/2020] [Indexed: 02/02/2023] Open
|
8
|
Marshall EL, Rajderkar D, Brown JL, Stepusin EJ, Borrego D, Duncan J, Sammet CL, Munneke JR, Kwan ML, Miglioretti DL, Smith-Bindman R, Bolch WE. A Scalable Database of Organ Doses for Common Diagnostic Fluoroscopy Procedures of Children: Procedures of Historical Practice for Use in Radiation Epidemiology Studies. Radiat Res 2019; 192:649-661. [PMID: 31609677 DOI: 10.1667/rr15445.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Assessment of health effects from low-dose radiation exposures in patients undergoing diagnostic imaging is an active area of research. High-quality dosimetry information pertaining to these medical exposures is generally not readily available to clinicians or epidemiologists studying radiation-related health risks. The purpose of this study was to provide methods for organ dose estimation in pediatric patients undergoing four common diagnostic fluoroscopy procedures: the upper gastrointestinal (UGI) series, the lower gastrointestinal (LGI) series, the voiding cystourethrogram (VCUG) and the modified barium swallow (MBS). Abstracted X-ray film data and physician interviews were combined to generate procedure outlines detailing X-ray beam projections, imaged anatomy, length of X-ray exposure, and presence and amount of contrast within imaged anatomy. Monte Carlo radiation transport simulations were completed for each of the four diagnostic fluoroscopy procedures across the 162-member (87 males and 75 females) University of Florida/National Cancer Institute pediatric phantom library, which covers variations in both subject height and weight. Absorbed doses to 28 organs, including the active marrow and bone endosteum, were assigned for all 162 phantoms by procedure. Additionally, we provide dose coefficients (DCs) in a series of supplementary tables. The DCs give organ doses normalized to procedure-specific dose metrics, including: air kerma-area product (µGy/mGy · cm2), air kerma at the reference point (µGy/µGy), number of spot films (SF) (µGy/number of SFs) and total fluoroscopy time (µGy/s). Organs accumulating the highest absorbed doses per procedure were as follows: kidneys between 0.9-25.4 mGy, 1.1-16.6 mGy and 1.1-9.7 mGy for the UGI, LGI and VCUG procedures, respectively, and salivary glands between 0.2-3.7 mGy for the MBS procedure. Average values of detriment-weighted dose, a phantom-specific surrogate for the effective dose based on ICRP Publication 103 tissue-weighting factors, were 0.98 mSv, 1.16 mSv, 0.83 mSv and 0.15 mSv for the UGI, LGI, VCUG and MBS procedures, respectively. Scalable database of organ dose coefficients by patient sex, height and weight, and by procedure exposure time, reference point air kerma, kerma-area product or number of spot films, allows clinicians and researchers to compute organ absorbed doses based on their institution-specific and patient-specific dose metrics. In addition to informing on patient dosimetry, this work has the potential to facilitate exposure assessments in epidemiological studies designed to investigate radiation-related risks.
Collapse
Affiliation(s)
| | | | - Justin L Brown
- Department of Medical Physics Program, College of Medicine, University of Florida, Gainesville, Florida
| | | | - David Borrego
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| | - James Duncan
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri
| | | | - Julie R Munneke
- Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois
| | - Marilyn L Kwan
- Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois
| | - Diana L Miglioretti
- Division of Research, Kaiser Permanente Northern California, Oakland, California
- Department of Public Health Sciences, University of California Davis School of Medicine, Sacramento, California
| | - Rebecca Smith-Bindman
- Department of Public Health Sciences, University of California Davis School of Medicine, Sacramento, California
| | - Wesley E Bolch
- J. Crayton Pruitt Family Department of Biomedical Engineering
| |
Collapse
|
9
|
Marshall EL, Rajderkar D, Brown JL, Stepusin EJ, Borrego D, Bolch WE. A scalable database of organ doses for common diagnostic fluoroscopy examinations of children: procedures of current practice at the University of Florida. Phys Med Biol 2019; 64:135023. [PMID: 31013486 DOI: 10.1088/1361-6560/ab1bad] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Of all the medical imaging modalities that utilize ionizing radiation, fluoroscopy proves to be the most difficult to assess values of patient organ dose owing to the dynamic and patient-specific nature of the irradiation geometry and its associated x-ray beam characteristics. With the introduction of the radiation dose structured report (RDSR) in the mid-2000s, however, computational tools have been developed to extract patient and procedure-specific data for each irradiation event of the study, and when coupled to a computational phantom of the patient, values of skin and internal organ dose may be assessed. Unfortunately, many legacy and even current diagnostic fluoroscopy units do not have RDSR reporting capabilities, thus limiting these dosimetry reporting advances. Nevertheless, knowledge of patient organ doses for patient care, as well as for radiation epidemiology studies, remains a research and regulatory priority. In this study, we created procedural outlines which document all radiation exposure information required for organ dose assessment, akin to a reference RDSR, for six common diagnostic fluoroscopy procedures performed at the University of Florida (UF) Shands Pediatric Hospital. These procedures include the voiding cystourethrogram, the gastrostomy-tube placement, the lower gastrointestinal study, the rehabilitation swallow, the upper gastrointestinal study, and the upper gastrointestinal study with follow through. These procedural outlines were used to develop an extensive database of organ doses for the 162-member UF/NCI (National Cancer Institute) library of pediatric hybrid phantoms, with each member varying combinations of sex, height, and weight. The organ dose assessment accounts for the varying x-ray fields, fluoroscopy time, relative concentration of x-ray contrast in the organs, and changes in the fluoroscope output due to patient size. Furthermore, we are also reporting organ doses normalized to total fluoroscopy time, reference point air kerma, and kerma-area product, effectively providing procedure dose coefficients. The extensive organ dose library produced in this study may be used prospectively for patient organ dose reporting or retrospectively in epidemiological studies of radiation-associated health risks.
Collapse
Affiliation(s)
- Emily L Marshall
- J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States of America. Present address: Diagnostic Physics Residency Program, Department of Radiology, University of Chicago, Chicago, IL, United States of America
| | | | | | | | | | | |
Collapse
|
10
|
Schmitz D, Vogl T, Nour-Eldin NEA, Radeleff B, Kröger JC, Mahnken AH, Ittrich H, Gehl HB, Plessow B, Böttcher J, Tacke J, Wispler M, Rosien U, Schorr W, Joerdens M, Glaser N, Fuchs ES, Tal A, Friesenhahn-Ochs B, Leimbach T, Höpner L, Weber M, Gölder S, Böhmig M, Hetjens S, Rudi J, Schegerer A. Patient radiation dose in percutaneous biliary interventions: recommendations for DRLs on the basis of a multicentre study. Eur Radiol 2019; 29:3390-3400. [PMID: 31016441 DOI: 10.1007/s00330-019-06208-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 03/20/2019] [Accepted: 03/27/2019] [Indexed: 12/26/2022]
Abstract
OBJECTIVE Percutaneous biliary interventions (PBIs) can be associated with a high patient radiation dose, which can be reduced when national diagnostic reference levels (DRLs) are kept in mind. The aim of this multicentre study was to investigate patient radiation exposure in different percutaneous biliary interventions, in order to recommend national DRLs. METHODS A questionnaire asking for the dose area product (DAP) and the fluoroscopy time (FT) in different PBIs with ultrasound- or fluoroscopy-guided bile duct punctures was sent to 200 advanced care hospitals. Recommended national DRLs are set at the 75th percentile of all DAPs. RESULTS Twenty-three facilities (9 interventional radiology depts. and 14 gastroenterology depts.) returned the questionnaire (12%). Five hundred sixty-five PBIs with 19 different interventions were included in the analysis. DAPs (range 4-21,510 cGy·cm2) and FTs (range 0.07-180.33 min) varied substantially depending on the centre and type of PBI. The DAPs of initial PBIs were significantly (p < 0.0001) higher (median 2162 cGy·cm2) than those of follow-up PBIs (median 464 cGy·cm2). There was no significant difference between initial PBIs with ultrasound-guided bile duct puncture (2162 cGy·cm2) and initial PBIs with fluoroscopy-guided bile duct puncture (2132 cGy·cm2) (p = 0.85). FT varied substantially (0.07-180.33 min). CONCLUSIONS DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. PBI with US-guided bile duct puncture did not reduce DAP, when compared to PBI with fluoroscopy-guided bile duct puncture. National DRLs of 4300 cGy·cm2 for initial PBIs and 1400 cGy·cm2 for follow-up PBIs are recommended. KEY POINTS • DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. • PBI with US-guided bile duct puncture did not reduce DAP when compared to PBI with fluoroscopy-guided bile duct puncture. • DRLs of 4300 cGy·cm2for initial PBIs (establishing a transhepatic tract) and 1400 cGy·cm2for follow-up PBIs (transhepatic tract already established) are recommended.
Collapse
Affiliation(s)
- Daniel Schmitz
- Department of Gastroenterology, Oncology and Diabetology, Theresienkrankenhaus and St. Hedwig Hospital, Academic Teaching Hospital of Heidelberg University, Bassermannstr.1, 68165, Mannheim, Germany.
| | - Thomas Vogl
- Institute for Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | | | - Boris Radeleff
- Department for Diagnostic and Interventional Radiology, Sana Municipal Hospital Hof, Hof, Germany
| | - Jens-Christian Kröger
- Institute for Diagnostic and Interventional Radiology, University Medicine Rostock, Rostock, Germany
| | - Andreas H Mahnken
- Institute for Diagnostic and Interventional Radiology, University Hospital Marburg, Marburg, Germany
| | - Harald Ittrich
- Clinic and Polyclinic for Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg, Hamburg, Germany
| | - Hans-Björn Gehl
- Institute for Diagnostic Radiology, Municipal Hospital Bielefeld, Bielefeld, Germany
| | - Bernd Plessow
- Radiological Institute, University Medicine Greifswald, Greifswald, Germany
| | - Joachim Böttcher
- Institute for Diagnostic and Interventional Radiology, SRH Wald-Klinikum Gera, Gera, Germany
| | - Josef Tacke
- Institute for Diagnostic and Interventional Radiology/Neuroradiology, Municipal Hospital Passau, Passau, Germany
| | - Markus Wispler
- Community Hospital Havelhöhe, Gastroenterology, Berlin, Germany
| | - Ulrich Rosien
- Medical Clinic, Israelite Hospital Hamburg, Hamburg, Germany
| | - Wolfgang Schorr
- Department of Gastroenterology and Interventional Endoscopy, Barmherzige Brüder Hospital Regensburg, Regensburg, Germany
| | - Markus Joerdens
- Department of Gastroenterology, Oncology and Infectiology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Nicolas Glaser
- Clinic for Internal Medicine II: Gastroenterology, Oncology, Endocrinology and Infectiology, University Hospital Freiburg, Freiburg, Germany
| | - Erik-Sebastian Fuchs
- Department of Gastroenterology, Infectiology, Diabetology and Gastrointestinal Oncology (Medical Clinic C), Ludwigshafen Municipal Hospital, Ludwigshafen, Germany
| | - Andrea Tal
- Medical Clinic I: Gastroenterology and Hepatology, Pneumology and Allergology, Endocrinology and Diabetology as Nutritional Medicine, University Hospital Frankfurt, Frankfurt, Germany
| | - Bettina Friesenhahn-Ochs
- Clinic for Internal Medicine II: Gastroenterology, Hepatology, Endocrinology, Diabetology and Nutritional Medicine, Saarland University Hospital, Homburg, Germany
| | - Thomas Leimbach
- Clinic for Gastroenterology, Hepatology, Gastrointestinal Oncology, Municipal Hospital Bogenhausen Munich, Munich, Germany
| | - Lars Höpner
- Clinic for Gastrointestinal Diseases/Medical Clinic I, Municipal Clinic of Braunschweig, Braunschweig, Germany
| | - Marko Weber
- Clinic for Internal Medicine IV: Gastroenterology, Hepatology, Infectiology, Interdisciplinary Endoscopy, University Hospital Jena, Jena, Germany
| | - Stefan Gölder
- Medical Clinic III - Gastroenterology, Municipal Hospital Augsburg, Augsburg, Germany
| | - Michael Böhmig
- Medical Clinic I (Gastroenterology, Hepatology, Oncology, Infectiology), Agaplesion Markus Hospital Frankfurt, Frankfurt, Germany
| | - Svetlana Hetjens
- Department of Medical Statistics and Biomathematics of Mannheim University Hospital, Heidelberg University-Hospital, Heidelberg, Germany
| | - Jochen Rudi
- Department of Gastroenterology, Oncology and Diabetology, Theresienkrankenhaus and St. Hedwig Hospital, Academic Teaching Hospital of Heidelberg University, Bassermannstr.1, 68165, Mannheim, Germany
| | - Alexander Schegerer
- Department for Radiation Protection and Health, Federal Office of Radiation Protection, Salzgitter, Germany
| |
Collapse
|
11
|
Kainz W, Neufeld E, Bolch WE, Graff CG, Kim CH, Kuster N, Lloyd B, Morrison T, Segars P, Yeom YS, Zankl M, Xu XG, Tsui BMW. Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019; 3:1-23. [PMID: 30740582 PMCID: PMC6362464 DOI: 10.1109/trpms.2018.2883437] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Over the past decades, significant improvements have been made in the field of computational human phantoms (CHPs) and their applications in biomedical engineering. Their sophistication has dramatically increased. The very first CHPs were composed of simple geometric volumes, e.g., cylinders and spheres, while current CHPs have a high resolution, cover a substantial range of the patient population, have high anatomical accuracy, are poseable, morphable, and are augmented with various details to perform functionalized computations. Advances in imaging techniques and semi-automated segmentation tools allow fast and personalized development of CHPs. These advances open the door to quickly develop personalized CHPs, inherently including the disease of the patient. Because many of these CHPs are increasingly providing data for regulatory submissions of various medical devices, the validity, anatomical accuracy, and availability to cover the entire patient population is of utmost importance. The article is organized into two main sections: the first section reviews the different modeling techniques used to create CHPs, whereas the second section discusses various applications of CHPs in biomedical engineering. Each topic gives an overview, a brief history, recent developments, and an outlook into the future.
Collapse
Affiliation(s)
- Wolfgang Kainz
- Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20993 USA
| | - Esra Neufeld
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | | | - Christian G Graff
- Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20993 USA
| | | | - Niels Kuster
- Swiss Federal Institute of Technology, ETH Zürich, and the Foundation for Research on Information Technologies in Society (IT'IS), Zürich, Switzerland
| | - Bryn Lloyd
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | - Tina Morrison
- Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20993 USA
| | | | | | - Maria Zankl
- Helmholtz Zentrum München German Research Center for Environmental Health, Munich, Germany
| | - X George Xu
- Rensselaer Polytechnic Institute, Troy, NY, USA
| | | |
Collapse
|
12
|
Marshall EL, Borrego D, Fudge JC, Rajderkar D, Bolch WE. Organ doses in pediatric patients undergoing cardiac-centered fluoroscopically guided interventions: Comparison of three methods for computational phantom alignment. Med Phys 2018; 45:10.1002/mp.13044. [PMID: 29896882 PMCID: PMC6292782 DOI: 10.1002/mp.13044] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 05/15/2018] [Accepted: 06/07/2018] [Indexed: 01/16/2023] Open
Abstract
PURPOSE To assess various computational phantom alignment techniques within Monte Carlo radiation transport models of pediatric fluoroscopically guided cardiac interventional studies. METHODS Logfiles, including all procedure radiation and machine data, were extracted from a Toshiba infinix-I unit in the University of Florida Pediatric Catheterization Laboratory for a cohort of 10 patients. Two different alignment methods were then tested against a ground truth standard based upon identification of a unique anatomic reference point within images co-registered to specific irradiation events within each procedure. The first alignment method required measurement of the distance from the edge of the exam table to the top of the patient's head (table alignment method). The second alignment method fixed the anatomic reference point to be the geometric center of the heart muscle, as all 10 studies were cardiac in nature. Monte Carlo radiation transport simulations were performed for each patient and intervention using morphometry-matched hybrid computational phantoms for the reference and two tested alignment methods. For each combination, absorbed doses were computed for 28 organs and root mean square organ doses were assessed and compared across the alignment methods. RESULTS The percent error in root mean square organ dose ranged from -57% to +41% for the table alignment method, and from -27% to +22% for the heart geometric centroid alignment method. Absorbed doses to specific organs, such as the heart and lungs, demonstrated higher accuracy in the heart geometric centroid alignment method, with average percent errors of 10% and 1.4%, respectively, compared to average percent errors of -32% and 24%, respectively, using the table alignment method. CONCLUSIONS Of the two phantom alignment methods investigated in this study, the use of an anatomical reference point - in this case the geometric centroid of the heart - provided a reliable method for radiation transport simulations of organ dose in pediatric interventional cardiac studies. This alignment method provides the added benefit of requiring no physician input, making retrospective calculations possible. Moving forward, additional anatomical reference methods can be tested to assess the reliability of anatomical reference points beyond cardiac centered procedures.
Collapse
Affiliation(s)
- Emily L Marshall
- J. Crayton Pruitt Family, Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - David Borrego
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, MD, USA
| | - James C Fudge
- Div. of Pediatric Cardiology, UF Health Congenital Heart Center, University of Florida, Gainesville, FL, USA
| | - Dhanashree Rajderkar
- Department of Radiology, Chief of Pediatric Radiology, University of Florida, Gainesville, FL, USA
| | - Wesley E Bolch
- J. Crayton Pruitt Family, Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| |
Collapse
|
13
|
Borrego D, Marshall EL, Tran T, Siragusa DA, Bolch WE. Physical validation of UF-RIPSA: A rapid in-clinic peak skin dose mapping algorithm for fluoroscopically guided interventions. J Appl Clin Med Phys 2018; 19:343-350. [PMID: 29577612 PMCID: PMC5978976 DOI: 10.1002/acm2.12312] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 07/21/2017] [Accepted: 02/13/2018] [Indexed: 12/03/2022] Open
Abstract
Purpose The purpose of this study was to experimentally validate UF‐RIPSA, a rapid in‐clinic peak skin dose mapping algorithm developed at the University of Florida using optically stimulated luminescent dosimeters (OSLDs) and tissue‐equivalent phantoms. Methods The OSLDs used in this study were InLightTM Nanodot dosimeters by Landauer, Inc. The OSLDs were exposed to nine different beam qualities while either free‐in‐air or on the surface of a tissue equivalent phantom. The irradiation of the OSLDs was then modeled using Monte Carlo techniques to derive correction factors between free‐in‐air exposures and more complex irradiation geometries. A grid of OSLDs on the surface of a tissue equivalent phantom was irradiated with two fluoroscopic x ray fields generated by the Siemens Artis zee bi‐plane fluoroscopic unit. The location of each OSLD within the grid was noted and its dose reading compared with UF‐RIPSA results. Results With the use of Monte Carlo correction factors, the OSLD's response under complex irradiation geometries can be predicted from its free‐in‐air response. The predicted values had a percent error of −8.7% to +3.2% with a predicted value that was on average 5% below the measured value. Agreement within 9% was observed between the values of the OSLDs and RIPSA when irradiated directly on the phantom and within 14% when the beam first traverses the tabletop and pad. Conclusions The UF‐RIPSA only computes dose values to areas of irradiated skin determined to be directly within the x ray field since the algorithm is based upon ray tracing of the reported reference air kerma value, with subsequent corrections for air‐to‐tissue dose conversion, x ray backscatter, and table/pad attenuation. The UF‐RIPSA algorithm thus does not include the dose contribution of scatter radiation from adjacent fields. Despite this limitation, UF‐RIPSA is shown to be fairly robust when computing skin dose to patients undergoing fluoroscopically guided interventions.
Collapse
Affiliation(s)
- David Borrego
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Emily L Marshall
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Trung Tran
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Daniel A Siragusa
- Radiology, Division of Vascular Interventional Radiology, University of Florida, Jacksonville, FL, USA
| | - Wesley E Bolch
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| |
Collapse
|
14
|
Marshall EL, Borrego D, Tran T, Fudge JC, Bolch WE. Evaluation of the UF/NCI hybrid computational phantoms for use in organ dosimetry of pediatric patients undergoing fluoroscopically guided cardiac procedures. Phys Med Biol 2018; 63:055006. [PMID: 29405126 DOI: 10.1088/1361-6560/aaad1d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Epidemiologic data demonstrate that pediatric patients face a higher relative risk of radiation induced cancers than their adult counterparts at equivalent exposures. Infants and children with congenital heart defects are a critical patient population exposed to ionizing radiation during life-saving procedures. These patients will likely incur numerous procedures throughout their lifespan, each time increasing their cumulative radiation absorbed dose. As continued improvements in long-term prognosis of congenital heart defect patients is achieved, a better understanding of organ radiation dose following treatment becomes increasingly vital. Dosimetry of these patients can be accomplished using Monte Carlo radiation transport simulations, coupled with modern anatomical patient models. The aim of this study was to evaluate the performance of the University of Florida/National Cancer Institute (UF/NCI) pediatric hybrid computational phantom library for organ dose assessment of patients that have undergone fluoroscopically guided cardiac catheterizations. In this study, two types of simulations were modeled. A dose assessment was performed on 29 patient-specific voxel phantoms (taken as representing the patient's true anatomy), height/weight-matched hybrid library phantoms, and age-matched reference phantoms. Two exposure studies were conducted for each phantom type. First, a parametric study was constructed by the attending pediatric interventional cardiologist at the University of Florida to model the range of parameters seen clinically. Second, four clinical cardiac procedures were simulated based upon internal logfiles captured by a Toshiba Infinix-i Cardiac Bi-Plane fluoroscopic unit. Performance of the phantom library was quantified by computing both the percent difference in individual organ doses, as well as the organ dose root mean square values for overall phantom assessment between the matched phantoms (UF/NCI library or reference) and the patient-specific phantoms. The UF/NCI hybrid phantoms performed at percent differences of between 15% and 30% for the parametric set of irradiation events. Among internal logfile reconstructed procedures, the UF/NCI hybrid phantoms performed with RMS organ dose values between 7% and 29%. Percent improvement in organ dosimetry via the use of hybrid library phantoms over the reference phantoms ranged from 6.6% to 93%. The use of a hybrid phantom library, Monte Carlo radiation transport methods, and clinical information on irradiation events provide a means for tracking organ dose in these radiosensitive patients undergoing fluoroscopically guided cardiac procedures.
Collapse
Affiliation(s)
- Emily L Marshall
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States of America. Present address: Diagnostic Physics Residency Program, Department of Radiology, University of Chicago, Chicago, IL 60637, United States of America
| | | | | | | | | |
Collapse
|