1
|
Li G, Duan L, Xie L, Hu T, Wei W, Bai L, Xiao Q, Liu W, Zhang L, Bai S, Yi Z. Deep learning for patient-specific quality assurance of volumetric modulated arc therapy: Prediction accuracy and cost-sensitive classification performance. Phys Med 2024; 125:104500. [PMID: 39191190 DOI: 10.1016/j.ejmp.2024.104500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 07/13/2024] [Accepted: 08/22/2024] [Indexed: 08/29/2024] Open
Abstract
PURPOSE To evaluate a deep learning model's performance in predicting and classifying patient-specific quality assurance (PSQA) results for volumetric modulated arc therapy (VMAT), aiming to streamline PSQA workflows and reduce the onsite measurement workload. METHODS A total of 761 VMAT plans were analyzed using 3D-MResNet to process multileaf collimator images and monitor unit data, with the gamma passing rate (GPR) as the output. Thresholds for the predicted GPR (Th-p) and measured GPR (Th-m) were established to aid in PSQA decision-making, using cost curves and error rates to assess classification performance. RESULTS The mean absolute errors of the model for the test set were 1.63 % and 2.38 % at 3 %/2 mm and 2 %/2 mm, respectively. For the classification of the PSQA results, Th-m was 88.3 % at 2 %/2 mm and 93.3 % at 3 %/2 mm. The lowest cost-sensitive error rates of 0.0127 and 0.0925 were obtained when Th-p was set as 91.2 % at 2 %/2 mm and 96.4 % at 3 %/2 mm, respectively. Additionally, the 2 %/2 mm classifier also achieved a lower total expected cost of 0.069 compared with 0.110 for the 3 %/2 mm classifier. The deep learning classifier under the 2 %/2 mm gamma criterion had a sensitivity and specificity of 100 % (10/10) and 83.5 % (167/200), respectively, for the test set. CONCLUSIONS The developed 3D-MResNet model can accurately predict and classify PSQA results based on VMAT plans. The introduction of a deep learning model into the PSQA workflow has considerable potential for improving the VMAT PSQA process and reducing workloads.
Collapse
Affiliation(s)
- Guangjun Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Lian Duan
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Lizhang Xie
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China
| | - Ting Hu
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China
| | - Weige Wei
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Long Bai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Qing Xiao
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Wenjie Liu
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China
| | - Lei Zhang
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China.
| | - Sen Bai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China.
| | - Zhang Yi
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China
| |
Collapse
|
2
|
Ma M, Li M, Zhang K, Ma P, Hu Z, Yan H, Men K, Dai J. Applying the six-sigma methodology to determine the limits of quality control (QC) tests for a specific linear accelerator. J Appl Clin Med Phys 2024:e14460. [PMID: 39072977 DOI: 10.1002/acm2.14460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 06/06/2024] [Accepted: 06/23/2024] [Indexed: 07/30/2024] Open
Abstract
PURPOSE We aimed to show the framework of the six-sigma methodology (SSM) that can be used to determine the limits of QC tests for the linear accelerator (Linac). Limits for QC tests are individually determined using the SSM. METHODS AND MATERIALS The SSM is based on the define-measure-analyze-improve-control (DMAIC) stages to improve the process. In the "define" stage, the limits of QC tests were determined. In the "measure" stage, a retrospective collection of daily QC data using a Machine Performance Check platform was performed from January 2020 to December 2022. In the "analyze" stage, the process of determining the limits was proposed using statistical analyses and process capability indices. In the "improve" stage, the capability index was used to calculate the action limits. The tolerance limit was established using the larger one of the control limits in the individual control chart (I-chart). In the "control" stage, daily QC data were collected prospectively from January 2023 to May 2023 to monitor the effect of action limits and tolerance limits. RESULTS A total of 798 sets of QC data including beam, isocenter, collimation, couch, and gantry tests were collected and analyzed. The Collimation Rotation offset test had the min-Cp, min-Cpk, min-Pp, and min-Ppk at 2.53, 1.99, 1.59, and 1.25, respectively. The Couch Rtn test had the max-Cp, max-Cpk, max-Pp, and max-Ppk at 31.5, 29.9, 23.4, and 22.2, respectively. There are three QC tests with higher action limits than the original tolerance. Some data on the I-chart of the beam output change, isocenter KV offset, and jaw X1 exceeded the lower tolerance and action limit, which indicated that a system deviation occurred and reminded the physicist to take action to improve the process. CONCLUSIONS The SSM is an excellent framework to use in determining the limits of QC tests. The process capability index is an important parameter that provides quantitative information on determining the limits of QC tests.
Collapse
Affiliation(s)
- Min Ma
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Minghui Li
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Ke Zhang
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Pan Ma
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zhihui Hu
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hui Yan
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Kuo Men
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianrong Dai
- National Cancer Center/National Clinical Research, Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
3
|
Russo S, Saez J, Esposito M, Bruschi A, Ghirelli A, Pini S, Scoccianti S, Hernandez V. Incorporating plan complexity into the statistical process control of volumetric modulated arc therapy pre-treatment verifications. Med Phys 2024; 51:3961-3971. [PMID: 38630979 DOI: 10.1002/mp.17081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 03/14/2024] [Accepted: 03/30/2024] [Indexed: 04/19/2024] Open
Abstract
BACKGROUND Statistical process control (SPC) is a powerful statistical tool for process monitoring that has been highly recommended in healthcare applications, including radiation therapy quality assurance (QA). The AAPM TG-218 report described the clinical implementation of SPC for Volumetric Modulated Arc Therapy (VMAT) pre-treatment verifications, pointing out the need to adjust tolerance limits based on plan complexity. However, the quantification of plan complexity and its integration into SPC remains an unresolved challenge. PURPOSE The primary aim of this study is to investigate the incorporation of plan complexity into the SPC framework for VMAT pre-treatment verifications. The study explores and evaluates various strategies for this incorporation, discussing their merits and limitations, and provides recommendations for clinical application. METHODS A retrospective analysis was conducted on 309 VMAT plans from diverse anatomical sites using the PTW OCTAVIUS 4D device for QA measurements. Gamma Passing Rates (GPR) were obtained, and lower control limits were computed using both the conventional Shewhart method and three heuristic methods (scaled weighted variance, weighted standard deviations, and skewness correction) to accommodate non-normal data distributions. The 'Identify-Eliminate-Recalculate' method was employed for robust analysis. Eight complexity metrics were analyzed and two distinct strategies for incorporating plan complexity into SPC were assessed. The first strategy focused on establishing control limits for different treatment sites, while the second was based on the determination of control limits as a function of individual plan complexity. The study extensively examines the correlation between control limits and plan complexity and assesses the impact of complexity metrics on the control process. RESULTS The control limits established using SPC were strongly influenced by the complexity of treatment plans. In the first strategy, a clear correlation was found between control limits and average plan complexity for each site. The second approach derived control limits based on individual plan complexity metrics, enabling tailored tolerance limits. In both strategies, tolerance limits inversely correlated with plan complexity, resulting in all highly complex plans being classified as in control. In contrast, when plans were collectively analyzed without considering complexity, all the out-of-control plans were highly complex. CONCLUSIONS Incorporating plan complexity into SPC for VMAT verifications requires meticulous and comprehensive analysis. To ensure overall process control, we advocate for stringent control and minimization of plan complexity during treatment planning, especially when control limits are adjusted based on plan complexity.
Collapse
Affiliation(s)
- Serenella Russo
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - Jordi Saez
- Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain
| | - Marco Esposito
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
- Medical Physics Program, The Abdus Salam International Centre for Theoretical Physics Trieste-Italy, Trieste, Italy
| | - Andrea Bruschi
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | | | - Silvia Pini
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | | | - Victor Hernandez
- Department of Medical Physics, Hospital Sant Joan de Reus, IISPV, Reus, Spain
- Universitat Rovira i Virgili (URV), Tarragona, Spain
| |
Collapse
|
4
|
Ezenkwu CP, Cannon S, Ibeke E. Monitoring carbon emissions using deep learning and statistical process control: a strategy for impact assessment of governments' carbon reduction policies. ENVIRONMENTAL MONITORING AND ASSESSMENT 2024; 196:231. [PMID: 38308016 PMCID: PMC10837261 DOI: 10.1007/s10661-024-12388-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 01/20/2024] [Indexed: 02/04/2024]
Abstract
Across the globe, governments are developing policies and strategies to reduce carbon emissions to address climate change. Monitoring the impact of governments' carbon reduction policies can significantly enhance our ability to combat climate change and meet emissions reduction targets. One promising area in this regard is the role of artificial intelligence (AI) in carbon reduction policy and strategy monitoring. While researchers have explored applications of AI on data from various sources, including sensors, satellites, and social media, to identify areas for carbon emissions reduction, AI applications in tracking the effect of governments' carbon reduction plans have been limited. This study presents an AI framework based on long short-term memory (LSTM) and statistical process control (SPC) for the monitoring of variations in carbon emissions, using UK annual CO2 emission (per capita) data, covering a period between 1750 and 2021. This paper used LSTM to develop a surrogate model for the UK's carbon emissions characteristics and behaviours. As observed in our experiments, LSTM has better predictive abilities than ARIMA, Exponential Smoothing and feedforward artificial neural networks (ANN) in predicting CO2 emissions on a yearly prediction horizon. Using the deviation of the recorded emission data from the surrogate process, the variations and trends in these behaviours are then analysed using SPC, specifically Shewhart individual/moving range control charts. The result shows several assignable variations between the mid-1990s and 2021, which correlate with some notable UK government commitments to lower carbon emissions within this period. The framework presented in this paper can help identify periods of significant deviations from a country's normal CO2 emissions, which can potentially result from the government's carbon reduction policies or activities that can alter the amount of CO2 emissions.
Collapse
Affiliation(s)
| | - San Cannon
- School of Creative and Cultural Business, Robert Gordon University, Aberdeen, UK
| | - Ebuka Ibeke
- School of Creative and Cultural Business, Robert Gordon University, Aberdeen, UK
| |
Collapse
|
5
|
Tan HQ, Lew KS, Wong YM, Chong WC, Koh CWY, Chua CGA, Yeap PL, Ang KW, Lee JCL, Park SY. Detecting outliers beyond tolerance limits derived from statistical process control in patient-specific quality assurance. J Appl Clin Med Phys 2024; 25:e14154. [PMID: 37683120 PMCID: PMC10860546 DOI: 10.1002/acm2.14154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 08/18/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023] Open
Abstract
BACKGROUND Tolerance limit is defined on pre-treatment patient specific quality assurance results to identify "out of the norm" dose discrepancy in plan. An out-of-tolerance plan during measurement can often cause treatment delays especially if replanning is required. In this study, we aim to develop an outlier detection model to identify out-of-tolerance plan early during treatment planning phase to mitigate the above-mentioned risks. METHODS Patient-specific quality assurance results with portal dosimetry for stereotactic body radiotherapy measured between January 2020 and December 2021 were used in this study. Data were divided into thorax and pelvis sites and gamma passing rates were recorded using 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria. Statistical process control method was used to determine six different site and criterion-specific tolerance and action limits. Using only the inliers identified with our determined tolerance limits, we trained three different outlier detection models using the plan complexity metrics extracted from each treatment field-robust covariance, isolation forest, and one class support vector machine. The hyperparameters were optimized using the F1-score calculated from both the inliers and validation outliers' data. RESULTS 308 pelvis and 200 thorax fields were used in this study. The tolerance (action) limits for 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria in the pelvis site are 99.1% (98.1%), 95.8% (91.1%), and 91.7% (86.1%), respectively. The tolerance (action) limits in the thorax site are 99.0% (98.7%), 97.0% (96.2%), and 91.5% (87.2%). One class support vector machine performs the best among all the algorithms. The best performing model in the thorax (pelvis) site achieves a precision of 0.56 (0.54), recall of 1.0 (1.0), and F1-score of 0.72 (0.70) when using the 2%/2 mm (2%/1 mm) criterion. CONCLUSION The model will help the planner to identify an out-of-tolerance plan early so that they can refine the plan further during the planning stage without risking late discovery during measurement.
Collapse
Affiliation(s)
- Hong Qi Tan
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| | - Kah Seng Lew
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Yun Ming Wong
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Wen Chuan Chong
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - Calvin Wei Yang Koh
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | | | - Ping Lin Yeap
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - Khong Wei Ang
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - James Cheow Lei Lee
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Sung Yong Park
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| |
Collapse
|
6
|
Xiao Q, Li G. Application and Challenges of Statistical Process Control in Radiation Therapy Quality Assurance. Int J Radiat Oncol Biol Phys 2024; 118:295-305. [PMID: 37604239 DOI: 10.1016/j.ijrobp.2023.08.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 07/21/2023] [Accepted: 08/08/2023] [Indexed: 08/23/2023]
Abstract
Quality assurance (QA) is important for ensuring precision in radiation therapy. The complexity and resource-intensive nature of QA has increased with the continual evolution of equipment and techniques. An effective approach is to improve the process control technology and resource optimization. Statistical process control is an economical and efficient tool that has been widely used to monitor, control, and improve quality management processes and is now being increasingly used for radiation therapy QA. This article reviews the development and methodology of statistical process control technology, evaluates its suitability in radiation therapy QA practices, and assesses its importance and challenges in optimizing radiation therapy QA processes.
Collapse
Affiliation(s)
- Qing Xiao
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Guangjun Li
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
7
|
Raveendran V, R GR, P T A, Bhasi S, C P R, Kinhikar RA. Moving towards process-based radiotherapy quality assurance using statistical process control. Phys Med 2023; 112:102651. [PMID: 37562233 DOI: 10.1016/j.ejmp.2023.102651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 07/16/2023] [Accepted: 08/01/2023] [Indexed: 08/12/2023] Open
Abstract
Monitoring Radiotherapy Quality Assurance (QA) using Statistical Process Control (SPC) methods has gained wide acceptance. The significance of understanding the SPC methodologies has increased among the medical physics community with the release of Task Group (TG) reports from the American Association of Physicists in Medicine (AAPM) on patient-specific QA (PSQA) (TG-218) and Proton therapy QA (TG-224). Even though these reports recommend using SPC for QA analysis, physicists have ambiguities and doubts in choosing proper SPC tools and methodologies. This review article summarises the utilisation of SPC methods for different Radiotherapy QAs published in the literature, such as PSQA, routine Linac QA and patient positional verification. QA analysis using SPC could assist the user in distinguishing between 'special' and 'routine' sources of variations in the QA, which can aid in reducing actions on false positive QA results. For improved PSQA monitoring, machine-specific, site-specific, and technique-specific Tolerance Limits and Action Limits derived from a two-stage SPC-based approach can be used. Adopting a combination of Shewhart's control charts and time-weighted control charts for routine Linac QA monitoring could add more insights to the QA process. Incorporating SPC tools into existing image review modules or introducing new SPC software packages specifically designed for clinical use can significantly enhance the image review process. Proper selection and having adequate knowledge of SPC tools are essential for efficient QA monitoring, which is a function of the type of QA data available, and the magnitude of process drift to be monitored.
Collapse
Affiliation(s)
- Vysakh Raveendran
- Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Navi Mumbai, Maharashtra, India.; Department of Physics, Noorul Islam Centre for Higher Education, Kumaracoil, Kanyakumari District, Tamil Nadu, India..
| | - Ganapathi Raman R
- Department of Physics, Saveetha Engineering College (Autonomous), Chennai, Tamil Nadu, India
| | - Anjana P T
- Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Navi Mumbai, Maharashtra, India
| | - Saju Bhasi
- Division of Radiation Physics, Regional Cancer Centre, Trivandrum, India
| | - Ranjith C P
- Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Navi Mumbai, Maharashtra, India
| | - Rajesh Ashok Kinhikar
- Department of Medical Physics, Tata Memorial Centre, Homi Bhabha National Institute Parel, Mumbai, India
| |
Collapse
|
8
|
Li G, Xiao Q, Dai G, Wang Q, Bai L, Zhang X, Zhang X, Duan L, Zhong R, Bai S. Guaranteed performance of individual control chart used in gamma passing rate-based patient-specific quality assurance. Phys Med 2023; 109:102581. [PMID: 37084678 DOI: 10.1016/j.ejmp.2023.102581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 03/20/2023] [Accepted: 04/06/2023] [Indexed: 04/23/2023] Open
Abstract
PURPOSE To assess the effect of sampling variability on the performance of individual charts (I-charts) for PSQA and provide a robust and reliable method for unknown PSQA processes. MATERIALS AND METHODS A total of 1327 pretreatment PSQAs were analyzed. Different datasets with samples in the range of 20-1000 were used to estimate the lower control limit (LCL). Based on the iterative "Identify-Eliminate-Recalculate" and direct calculation without any outlier filtering procedures, five I-charts methods, namely the Shewhart, quantile, scaled weighted variance (SWV), weighted standard deviation (WSD), and skewness correction (SC) method, were used to compute the LCL. The average run length (ARL0) and false alarm rate (FAR0) were calculated to evaluate the performance of LCL. RESULTS The ground truth of the values of LCL, FAR0, and ARL0 obtained via in-control PSQAs were 92.31%, 0.135%, and 740.7, respectively. Further, for in-control PSQAs, the width of the 95% confidence interval of LCL values for all methods tended to decrease with the increase in sample size. In all sample ranges of in-control PSQAs, only the median LCL and ARL0 values obtained via WSD and SWV methods were close to the ground truth. For the actual unknown PSQAs, based on the "Identify-Eliminate-Recalculate" procedure, only the median LCL values obtained by the WSD method were closest to the ground truth. CONCLUSIONS Sampling variability seriously affected the I-chart performance in PSQA processes, particularly for small samples. For unknown PSQAs, the WSD method based on the implementation of the iterative "Identify-Eliminate-Recalculate" procedure exhibited sufficient robustness and reliability.
Collapse
Affiliation(s)
- Guangjun Li
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Qing Xiao
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Guyu Dai
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Qiang Wang
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Long Bai
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Xiangbin Zhang
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Xiangyu Zhang
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Lian Duan
- Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia 19104, United States
| | - Renming Zhong
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Sen Bai
- Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China; Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China.
| |
Collapse
|
9
|
Guo Y, Hu J, Li Y, Ran J, Cai H. Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features. Sci Rep 2023; 13:4051. [PMID: 36899027 PMCID: PMC10006091 DOI: 10.1038/s41598-023-30719-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 02/28/2023] [Indexed: 03/12/2023] Open
Abstract
In radiotherapy, air-filled ion chamber detectors are ubiquitously used in routine dose measurements for treatment planning. However, its use has been restricted by intrinsic low spatial resolution barriers. We developed one procedure for patient-specific quality assurance (QA) in arc radiotherapy by coalescing two adjacent measurement images into a single image to improve spatial resolution and sampling frequency, and investigated how different spatial resolutions affect the QA results. PTW 729 and 1500 ion chamber detectors were used for dosimetric verification via coalescing two measurements with 5 mm-couch shift and the isocenter, and only isocenter measurement, which we call coalescence and standard acquisition (SA). Statistical process control (SPC), process capability analysis (PCA), and receiver operating characteristic (ROC) curve were used to compare the performance of the two procedures in determining tolerance levels and identifying clinically relevant errors. By analyzing 1256 γ values calculated on interpolated data points, our results indicated that detector 1500 showed higher averages in coalescence cohorts at different tolerance criteria and the dispersion degrees were spread out smaller. Detector 729 yielded a slightly lower process capability of 0.79, 0.76, 1.10, and 1.34, but detector 1500 exhibited somewhat different results of 0.94, 1.42, 1.19, and 1.60 in magnitude. The results of SPC individual control chart showed that cases in coalescence cohorts with γ values lowering its lower control limit (LCL) were greater than those in SA cohorts for detector 1500. A combination of the width of multi-leaf collimator (MLC) leaf, the cross-sectional area of the single detector, and the spacing between adjacent detectors might lead to discrepancies in percent γ values across diverse spatial resolution scenarios. The accuracy of reconstructed volume dose is mainly determined by the interpolation algorithm used in dosimetric systems. The magnitude of filling factor in the ion chamber detectors determined its ability to detect dose deviations. SPC and PCA results indicated that coalescence procedure could detect more potential failure QA results than SA while enhancing action thresholds.
Collapse
Affiliation(s)
- Yixiao Guo
- Department of Radiation Oncology, Gansu Provincial Hospital, Lanzhou, 730000, People's Republic of China
| | - Jinyan Hu
- Department of Oncology, Longhua District People's Hospital, Shenzhen, 518109, People's Republic of China
| | - Yang Li
- Department of Radiation Oncology, Weifang People's Hospital, Weifang, 261000, People's Republic of China
| | - Juntao Ran
- Department of Radiation Oncology, The First Hospital of Lanzhou University, Lanzhou, 730000, People's Republic of China
| | - Hongyi Cai
- Department of Radiation Oncology, Gansu Provincial Hospital, Lanzhou, 730000, People's Republic of China.
| |
Collapse
|
10
|
Mehrens H, Douglas R, Gronberg M, Nealon K, Zhang J, Court L. Statistical process control to monitor use of a web-based autoplanning tool. J Appl Clin Med Phys 2022; 23:e13803. [PMID: 36300872 PMCID: PMC9797174 DOI: 10.1002/acm2.13803] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 08/29/2022] [Accepted: 09/02/2022] [Indexed: 01/01/2023] Open
Abstract
PURPOSE To investigate the use of statistical process control (SPC) for quality assurance of an integrated web-based autoplanning tool, Radiation Planning Assistant (RPA). METHODS Automatically generated plans were downloaded and imported into two treatment planning systems (TPSs), RayStation and Eclipse, in which they were recalculated using fixed monitor units. The recalculated plans were then uploaded back to the RPA, and the mean dose differences for each contour between the original RPA and the TPSs plans were calculated. SPC was used to characterize the RPA plans in terms of two comparisons: RayStation TPS versus RPA and Eclipse TPS versus RPA for three anatomical sites, and variations in the machine parameters dosimetric leaf gap (DLG) and multileaf collimator transmission factor (MLC-TF) for two algorithms (Analytical Anisotropic Algorithm [AAA]) and Acuros in the Eclipse TPS. Overall, SPC was used to monitor the process of the RPA, while clinics would still perform their routine patient-specific QA. RESULTS For RayStation, the average mean percent dose differences across all contours were 0.65% ± 1.05%, -2.09% ± 0.56%, and 0.28% ± 0.98% and average control limit ranges were 1.89% ± 1.32%, 2.16% ± 1.31%, and 2.65% ± 1.89% for the head and neck, cervix, and chest wall, respectively. In contrast, Eclipse's average mean percent dose differences across all contours were -0.62% ± 0.34%, 0.32% ± 0.23%, and -0.91% ± 0.98%, while average control limit ranges were 1.09% ± 0.77%, 3.69% ± 2.67%, 2.73% ± 1.86%, respectively. Averaging all contours and removing outliers, a 0% dose difference corresponded with a DLG value of 0.202 ± 0.019 cm and MLC-TF value of 0.020 ± 0.001 for Acuros and a DLG value of 0.135 ± 0.031 cm and MLC-TF value of 0.015 ± 0.001 for AAA. CONCLUSIONS Differences in mean dose and control limits between RPA and two separately commissioned TPSs were determined. With varying control limits and means, SPC provides a flexible and useful process quality assurance tool for monitoring a complex automated system such as the RPA.
Collapse
Affiliation(s)
- Hunter Mehrens
- Department of Radiation PhysicsThe University of Texas MD Anderson Cancer CenterHoustonTexasUSA,The University of Texas MD Anderson Graduate School of Biomedical ScienceHoustonTexasUSA
| | - Raphael Douglas
- Department of Radiation PhysicsThe University of Texas MD Anderson Cancer CenterHoustonTexasUSA
| | - Mary Gronberg
- Department of Radiation PhysicsThe University of Texas MD Anderson Cancer CenterHoustonTexasUSA,The University of Texas MD Anderson Graduate School of Biomedical ScienceHoustonTexasUSA
| | - Kelly Nealon
- Department of Radiation PhysicsThe University of Texas MD Anderson Cancer CenterHoustonTexasUSA,The University of Texas MD Anderson Graduate School of Biomedical ScienceHoustonTexasUSA
| | - Joy Zhang
- Department of Radiation PhysicsThe University of Texas MD Anderson Cancer CenterHoustonTexasUSA
| | - Laurence Court
- Department of Radiation PhysicsThe University of Texas MD Anderson Cancer CenterHoustonTexasUSA
| |
Collapse
|
11
|
Zhang H, Lu W, Cui H, Li Y, Yi X. Assessment of Statistical Process Control Based DVH Action Levels for Systematic Multi-Leaf Collimator Errors in Cervical Cancer RapidArc Plans. Front Oncol 2022; 12:862635. [PMID: 35664736 PMCID: PMC9157499 DOI: 10.3389/fonc.2022.862635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 04/19/2022] [Indexed: 11/18/2022] Open
Abstract
Background In the patient-specific quality assurance (QA), DVH is a critical clinically relevant parameter that is finally used to determine the safety and effectiveness of radiotherapy. However, a consensus on DVH-based action levels has not been reached yet. The aim of this study is to explore reasonable DVH-based action levels and optimal DVH metrics in detecting systematic MLC errors for cervical cancer RapidArc plans. Methods In this study, a total of 148 cervical cancer RapidArc plans were selected and measured with COMPASS 3D dosimetry system. Firstly, the patient-specific QA results of 110 RapidArc plans were retrospectively reviewed. Then, DVH-based action limits (AL) and tolerance limits (TL) were obtained by statistical process control. Secondly, systematic MLC errors were introduced in 20 RapidArc plans, generating 380 modified plans. Then, the dose difference (%DE) in DVH metrics between modified plans and original plans was extracted from measurement results. After that, the linear regression model was used to investigate the detection limits of DVH-based action levels between %DE and systematic MLC errors. Finally, a total of 180 test plans (including 162 error-introduced plans and 18 original plans) were prepared for validation. The error detection rate of DVH-based action levels was compared in different DVH metrics of 180 test plans. Results A linear correlation was found between systematic MLC errors and %DE in all DVH metrics. Based on linear regression model, the systematic MLC errors between -0.94 mm and 0.88 mm could be caught by the TL of PTV95 ([-1.54%, 1.51%]), and the systematic MLC errors between -1.00 mm and 0.80 mm could also be caught by the TL of PTVmean ([-2.06%, 0.38%]). In the validation, for original plans, PTV95 showed the minimum error detection rate of 5.56%. For error-introduced plans with systematic MLC errors more than 1mm, PTVmean showed the maximum error detection rate of 88.89%, and then was followed by PTV95 (86.67%). All the TL of DVH metrics showed a poor error detection rate in identifying error-induced plans with systematic MLC errors less than 1mm. Conclusion In 3D quality assurance of cervical cancer RapidArc plans, process-based tolerance limits showed greater advantages in distinguishing plans introduced with systematic MLC errors more than 1mm, and reasonable DVH-based action levels can be acquired through statistical process control. During DVH-based verification, main focus should be on the DVH metrics of target volume. OARs in low-dose regions were found to have a relatively higher dose sensitivity to smaller systematic MLC errors, but may be accompanied with higher false error detection rate.
Collapse
Affiliation(s)
- Hanyin Zhang
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Wenli Lu
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Haixia Cui
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Ying Li
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xin Yi
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
12
|
Stasinou D, Patatoukas G, Kollaros N, Diamantopoulos S, Kypraiou E, Kougioumtzopoulou A, Kouloulias V, Efstathopoulos E, Platoni K. Implementation of TG-218 for patient specific QA Tolerance and Action Limits determination: Gamma passing rates evaluation using 3DVH software. Med Phys 2022; 49:4322-4334. [PMID: 35560362 DOI: 10.1002/mp.15703] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 03/18/2022] [Accepted: 04/26/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To determine the tolerance (TL) and action limits (AL) of gamma passing rates (%GP) for Volumetric-Modulated Arc Therapy (VMAT) patient-specific quality assurance (PSQA), according to the AAPM TG-218 recommendations, and to evaluate comparatively the clinical relevance of 2D%GP and 3D%GP. MATERIALS AND METHODS PSQA was performed for 100 head and neck (H&N) and 73 prostate cancer VMAT treatment plans. Measurements were acquired using a cylindrical water equivalent phantom, hollow in the center, allowing measurements with homogeneous or heterogeneous inserts. LINAC delivered dose distributions were compared to the ones calculated from the treatment planning system (TPS) through gamma index. TL and AL were determined through the computation of 2D%GP, using the recommended acceptance criteria. Dose-volume histograms (DVH) were reconstructed from the measurements using a commercially available software, to detect the dosimetric differences (%DE) between the compared dose distributions. Utilizing the estimated dose on the patient anatomy, structure specific %GP (3D%GP) were calculated. The 3D%GP were compared to the 2D%GP ones, based on their correlation with the %DE. Each metric's sensitivity was determined through receiver operator characteristic (ROC) analysis. RESULTS TL and AL were in concordance with the universal ones, regarding the prostate cancer cases, but were lower for the H&N cases. Evaluation of %DE did not deem the plans unacceptable. The 2D%GP and the 3D%GP did not differ significantly regarding their correlation with %DE. For prostate plans, %GP sensitivity was higher than for H&N cases. CONCLUSIONS Determination of institutional specific TL and AL allow the monitoring of the PSQA procedure, yet for plans close to the limits clinically relevant metrics should be used before they are deemed unacceptable, for the process to be of higher sensitivity and efficiency. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Despoina Stasinou
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - George Patatoukas
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Nikos Kollaros
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Stefanos Diamantopoulos
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Efrosyni Kypraiou
- Radiation Therapy Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Andromachi Kougioumtzopoulou
- Radiation Therapy Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Vasilios Kouloulias
- Radiation Therapy Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Efstathios Efstathopoulos
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| | - Kalliopi Platoni
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, University General Hospital 'Attikon', 1 Rimini Street, Haidari, Athens, 124 62, Greece
| |
Collapse
|
13
|
Xiao Q, Bai L, Li G, Zhang X, Li Z, Duan L, Peng R, Zhong R, Wang Q, Wang X, Bai S. A robust approach to establish tolerance limits for the gamma passing rate-based patient-specific quality assurance using the heuristic control charts. Med Phys 2021; 49:1312-1330. [PMID: 34778963 DOI: 10.1002/mp.15346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 10/29/2021] [Accepted: 11/01/2021] [Indexed: 02/05/2023] Open
Abstract
PURPOSE Establishing the tolerance limits of patient-specific quality assurance (PSQA) processes based on the gamma passing rate (GPR) by using normal statistical process control (SPC) methods involves certain problems. The aim of this study was threefold: (a) to show that the heuristic SPC method can replace the quantile method for establishing tolerance limits in PSQA processes and is more robust, (b) to introduce an iterative procedure of "Identify-Eliminate-Recalculate" for establishing the tolerance limits in PSQA processes with unknown states based on retrospective GPRs, and (c) to recommend a workflow to define tolerance limits based on actual clinical retrospective GPRs. MATERIALS AND METHODS A total of 1671 volumetric-modulated arc therapy (VMAT) pretreatment plans were measured on four linear accelerators (linacs) and analyzed by treatment sites using the GPRs under the 2%/2 mm, 3%/2 mm, and 3%/3 mm criteria. Normality testing was performed using the Anderson-Darling (AD) statistic and the optimal distributions of GPRs were determined using the Fitter Python package. The iterative "Identify-Eliminate-Recalculate" procedure was used to identify the PSQA outliers. The tolerance limits of the initial PSQAs, remaining PSQAs after elimination, and in-control PSQAs after correction were calculated using the conventional Shewhart method, two transformation methods, three heuristic methods, and two quantile methods. The tolerance limits of PSQA processes with different states for the respective methods, linacs, and treatment sites were comprehensively compared and analyzed. RESULTS It was found that 75% of the initial PSQA processes and 63% of the in-control processes were non-normal (AD test, p < 0.05). The optimal distributions of GPRs for the initial and in-control PSQAs varied with different linacs and treatment sites. In the implementation of the "Identify-Eliminate-Recalculate" procedure, the quantile methods could not identify the out-of-control PSQAs effectively due to the influence of outliers. The tolerance limits of the in-control PSQAs, calculated using the quantile of optimal fitting distributions, represented the ground truth. The tolerance limits of the in-control PSQAs and remaining PSQAs after elimination calculated using the heuristic methods were considerably close to the ground truth (the maximum average absolute deviations were 0.50 and 1.03%, respectively). Some transformation failures occurred under both transformation methods. For the in-control PSQAs at 3%/2 mm gamma criteria, the maximum differences in the tolerance limits for four linacs and different treatment sites were 3.10 and 5.02%, respectively. CONCLUSIONS The GPR distributions of PSQA processes vary with different linacs and treatment sites but most are skewed. In applying SPC methodologies to PSQA processes, heuristic methods are robust. For in-control PSQA processes, the tolerance limits calculated by heuristic methods are in good agreement with the ground truth. For unknown PSQA processes, the tolerance limits calculated by the heuristic methods after the iterative "Identify-Eliminate-Recalculate" procedure are closest to the ground truth. Setting linac- and treatment site-specific tolerance limits for PSQA processes is necessary for clinical applications.
Collapse
Affiliation(s)
- Qing Xiao
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Long Bai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Guangjun Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Xiangbin Zhang
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Zhibin Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Lian Duan
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Ruilin Peng
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Renming Zhong
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Qiang Wang
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Xuetao Wang
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Sen Bai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| |
Collapse
|
14
|
Performance assessment of surface-guided radiation therapy and patient setup in head-and-neck and breast cancer patients based on statistical process control. Phys Med 2021; 89:243-249. [PMID: 34428608 DOI: 10.1016/j.ejmp.2021.08.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/17/2021] [Accepted: 08/10/2021] [Indexed: 02/05/2023] Open
Abstract
PURPOSE To assess the effectiveness of SGRT in clinical applications through statistical process control (SPC). METHODS Taking the patients' positioning through optical surface imaging (OSI) as a process, the average level of process execution was defined as the process mean. Setup errors detected by cone-beam computed tomography (CBCT) and OSI were extracted for head-and-neck cancer (HNC) and breast cancer patients. These data were used to construct individual and exponentially weighted moving average (EWMA) control charts to analyze outlier fractions and small process shifts from the process mean. Using the control charts and process capability indices derived from this process, the patient positioning-related OSI performance and setup error were analyzed for each patient. RESULTS Outlier fractions and small shifts from the process mean that are indicative of setup errors were found to be widely prevalent, with the outliers randomly distributed between fractions. A systematic error of up to 1.6 mm between the OSI and CBCT results was observed in all directions, indicating a significantly degraded OSI performance. Adjusting this systematic error for each patient using setup errors of the first five fractions could effectively mitigate these effects. Process capability analysis following adjustment for systematic error indicated that OSI performance was acceptable (process capability index Cpk = 1.0) for HNC patients but unacceptable (Cpk < 0.75) for breast cancer patients. CONCLUSION SPC is a powerful tool for detecting the outlier fractions and process changes. Our application of SPC to patient-specific evaluations validated the suitability of OSI in clinical applications involving patient positioning.
Collapse
|
15
|
The status of medical physics in radiotherapy in China. Phys Med 2021; 85:147-157. [PMID: 34010803 DOI: 10.1016/j.ejmp.2021.05.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 05/01/2021] [Accepted: 05/03/2021] [Indexed: 01/09/2023] Open
Abstract
PURPOSE To present an overview of the status of medical physics in radiotherapy in China, including facilities and devices, occupation, education, research, etc. MATERIALS AND METHODS: The information about medical physics in clinics was obtained from the 9-th nationwide survey conducted by the China Society for Radiation Oncology in 2019. The data of medical physics in education and research was collected from the publications of the official and professional organizations. RESULTS By 2019, there were 1463 hospitals or institutes registered to practice radiotherapy and the number of accelerators per million population was 1.5. There were 4172 medical physicists working in clinics of radiation oncology. The ratio between the numbers of radiation oncologists and medical physicists is 3.51. Approximately, 95% of medical physicists have an undergraduate or graduate degrees in nuclear physics and biomedical engineering. 86% of medical physicists have certificates issued by the Chinese Society of Medical Physics. There has been a fast growth of publications by authors from mainland of China in the top international medical physics and radiotherapy journals since 2018. CONCLUSIONS Demand for medical physicists in radiotherapy increased quickly in the past decade. The distribution of radiotherapy facilities in China became more balanced. High quality continuing education and training programs for medical physicists are deficient in most areas. The role of medical physicists in the clinic has not been clearly defined and their contributions have not been fully recognized by the community.
Collapse
|
16
|
Roy A, Widjaja R, Wang M, Cutright D, Gopalakrishnan M, Mittal BB. Treatment plan quality control using multivariate control charts. Med Phys 2021; 48:2118-2126. [PMID: 33621381 DOI: 10.1002/mp.14795] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Revised: 01/19/2021] [Accepted: 02/15/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Statistical process control tools such as control charts were recommended by the American Association of Physicists in Medicine (AAPM) Task Group 218 for radiotherapy quality assurance. However, the tools needed to analyze multivariate, correlated data that are often encountered in treatment plan quality measures, are lacking. In this study, we develop quality control tools that can model multivariate plan quality measures with correlations and account for patient-specific risk factors, without adding a significant burden to clinical workflow. METHODS AND MATERIALS A multivariate, quality control chart is developed that includes a risk-adjustment model, Hotelling's T2 statistic, and principal component analysis (PCA). Principal component analysis accounts for correlations among a set of organ-at-risk (OAR) dose-volume histogram (DVH) points that serves as proxies for plan quality. Risk-adjustment models estimate the principal components from PCA using a set of patient- and treatment-specific risk factors. The resulting residuals from the risk-adjustment models are used to compute the Hotelling's T2 statistic; the corresponding multivariate control chart is then plotted based on the beta distribution followed by the statistic. Further, the box-cox transformation is used to account for non-normality in DVH points. We investigate the application of the proposed methodology via three multivariate control charts - a conventional chart that ignores risk-adjustment and PCA, a risk-adjusted chart ignoring PCA, and a PCA-based, risk-adjusted chart. These control charts are evaluated on 69 head-and-neck cases. RESULTS The conventional multivariate control chart fails to account for important patient-specific risk factors, including volumes and cross-sectional areas of the tumor and OARs and distances in-between. This failure leads to a larger number of false alarms. While the multivariate risk-adjusted control chart is able to reduce false alarms, it fails to account for correlations in DVH points. The multivariate PCA-based, risk-adjusted control chart can detect unusual plans after accounting for the correlations. By replanning, improvements are shown on an unusual plan identified by both risk-adjusted methods. CONCLUSIONS The multivariate risk-adjusted control chart developed here enables quality control of plans prior to delivery. This methodology is generic and can be readily applied for other radiotherapy quality assurance protocols, such as gamma analysis pass rates.
Collapse
Affiliation(s)
- Arkajyoti Roy
- Department of Management Science and Statistics, University of Texas at San Antonio, San Antonio, TX, 78249, USA
| | - Reisa Widjaja
- Department of Management Science and Statistics, University of Texas at San Antonio, San Antonio, TX, 78249, USA
| | - Min Wang
- Department of Management Science and Statistics, University of Texas at San Antonio, San Antonio, TX, 78249, USA
| | - Dan Cutright
- Department of Radiation Oncology, University of Chicago Medical Center, Chicago, IL, 60637, USA
| | - Mahesh Gopalakrishnan
- Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - Bharat B Mittal
- Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| |
Collapse
|