1
|
Riemann LT, Aigner CS, Mekle R, Speck O, Rose G, Ittermann B, Schmitter S, Fillmer A. Fourier-based decomposition for simultaneous 2-voxel MRS acquisition with 2SPECIAL. Magn Reson Med 2022; 88:1978-1993. [PMID: 35906900 DOI: 10.1002/mrm.29369] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 05/17/2022] [Accepted: 05/31/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE To simultaneously acquire spectroscopic signals from two MRS voxels using a multi-banded 2 spin-echo, full-intensity acquired localized (2SPECIAL) sequence, and to decompose the signal to their respective regions by a novel voxel-GRAPPA (vGRAPPA) decomposition approach for in vivo brain applications at 7 T. METHODS A wideband, uniform rate, smooth truncation (WURST) multi-banded pulse was incorporated into SPECIAL to implement 2SPECIAL for simultaneous multi-voxel spectroscopy (sMVS). To decompose the acquired data, the voxel-GRAPPA decomposition algorithm is introduced, and its performance is compared to the SENSE-based decomposition. Furthermore, the limitations of two-voxel excitation concerning the multi-banded adiabatic inversion pulse, as well as of the combined B0 shim and B1 + adjustments, are evaluated. RESULTS It was successfully shown that the 2SPECIAL sequence enables sMVS without a significant loss in SNR while reducing the total scan time by 21.6% compared to two consecutive acquisitions. The proposed voxel-GRAPPA algorithm properly reassigns the signal components to their respective origin region and shows no significant differences to the well-established SENSE-based algorithm in terms of leakage (both <10%) or Cramér-Rao lower bounds (CRLB) for in vivo applications, while not requiring the acquisition of additional sensitivity maps and thus decreasing motion sensitivity. CONCLUSION The use of 2SPECIAL in combination with the novel voxel-GRAPPA decomposition technique allows a substantial reduction of measurement time compared to the consecutive acquisition of two single voxels without a significant decrease in spectral quality or metabolite quantification accuracy and thus provides a new option for multiple-voxel applications.
Collapse
Affiliation(s)
- Layla Tabea Riemann
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig und Berlin, Germany
| | | | - Ralf Mekle
- Center for Stroke Research Berlin, Charité-Universitätsmedizin, Berlin, Germany
| | - Oliver Speck
- Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany.,Research Campus STIMULATE, Magdeburg, Germany
| | - Georg Rose
- Research Campus STIMULATE, Magdeburg, Germany.,Institut für Medizintechnik, Otto-von-Guericke University, Magdeburg, Germany
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig und Berlin, Germany
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig und Berlin, Germany.,Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota.,Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Ariane Fillmer
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig und Berlin, Germany
| |
Collapse
|
2
|
He X, Auerbach EJ, Garwood M, Kobayashi N, Wu X, Metzger GJ. Parallel transmit optimized 3D composite adiabatic spectral-spatial pulse for spectroscopy. Magn Reson Med 2021; 86:17-32. [PMID: 33497006 PMCID: PMC8545499 DOI: 10.1002/mrm.28682] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 12/22/2020] [Accepted: 12/23/2020] [Indexed: 01/05/2023]
Abstract
PURPOSE To develop a 3D composite adiabatic spectral-spatial pulse for refocusing in spin-echo spectroscopy acquisitions and to compare its performance against standard acquisition methods. METHODS A 3D composite adiabatic pulse was designed by modulating a train of parallel transmit-optimized 2D subpulses with an adiabatic envelope. The spatial and spectral profiles were simulated and validated by experiments to demonstrate the feasibility of the design in both single and double spin-echo spectroscopy acquisitions. Phantom and in vivo studies were performed to evaluate the pulse performance and compared with semi-LASER with respect to localization performance, sequence timing, signal suppression, and specific absorption rate. RESULTS Simultaneous 2D spatial localization with water and lipid suppression was achieved with the designed refocusing pulse, allowing high-quality spectra to be acquired with shorter minimum TE/TR, reduced SAR, as well as adaptation to spatially varying B0 and B 1 + field inhomogeneities in both prostate and brain studies. CONCLUSION The proposed composite pulse can serve as a more SAR efficient alternative to conventional localization methods such as semi-LASER at ultrahigh field for spin echo-based spectroscopy studies. Subpulse parallel-transmit optimization provides the flexibility to manage the tradeoff among multiple design criteria to accommodate different field strengths and applications.
Collapse
Affiliation(s)
- Xiaoxuan He
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States
| | - Edward J. Auerbach
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States
| | - Michael Garwood
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States
| | - Naoharu Kobayashi
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States
| | - Xiaoping Wu
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States
| | - Gregory J. Metzger
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States
| |
Collapse
|
3
|
On the reproducibility of hippocampal MEGA-sLASER GABA MRS at 7T using an optimized analysis pipeline. MAGNETIC RESONANCE MATERIALS IN PHYSICS, BIOLOGY AND MEDICINE 2021; 34:427-436. [PMID: 32865653 PMCID: PMC8154804 DOI: 10.1007/s10334-020-00879-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 07/28/2020] [Accepted: 07/30/2020] [Indexed: 11/05/2022]
Abstract
Objectives GABA is the most important inhibitory neurotransmitter. Thus, variation in its concentration is connected to a wide variety of diseases. However, the low concentration and the overlap of more prominent resonances hamper GABA quantification using MR spectroscopy. The hippocampus plays a pivotal role in neurodegeneration. Susceptibility discontinuities in the vicinity of the hippocampus cause strong B0 inhomogeneities, impeding GABA spectroscopy. The aim of this work is to improve the reproducibility of hippocampal GABA+ MRS. Methods The GABA+/total creatine ratio in the hippocampus was measured using a MEGA-sLASER sequence at 7 Tesla. 10 young healthy volunteers participated in the study. A dedicated pre-processing approach was established. Spectral quantification was performed with Tarquin. The quantification parameters were carefully adjusted to ensure optimal quantification. Results An inter-subject coefficient of variation of the GABA+/total creatine of below 15% was achieved. Additional to spectral registration, which is essential to obtain reproducible GABA measures, eddy current compensation and additional difference artifact suppression improved the reproducibility. The mean FWHM was 23.1 Hz (0.078 ppm). Conclusion The increased spectral dispersion of ultra-high-field spectroscopy allows for reproducible spectral quantification, despite a very broad line width. The achieved reproducibility enables the routine use of hippocampal GABA spectroscopy at 7 Tesla. Electronic supplementary material The online version of this article (10.1007/s10334-020-00879-9) contains supplementary material, which is available to authorized users.
Collapse
|
4
|
Waxmann P, Mekle R, Schubert F, Brühl R, Kuehne A, Lindel TD, Seifert F, Speck O, Ittermann B. A new sequence for shaped voxel spectroscopy in the human brain using 2D spatially selective excitation and parallel transmission. NMR IN BIOMEDICINE 2016; 29:1028-1037. [PMID: 27254102 DOI: 10.1002/nbm.3558] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 04/04/2016] [Accepted: 04/19/2016] [Indexed: 06/05/2023]
Abstract
Spatially selective excitation in two dimensions (2D-SSE) utilizing parallel transmission was applied as a means to acquire signal from voxels adapted to the anatomy of interest for in vivo (1) H MR spectroscopy. A novel method to select spectroscopy voxels with arbitrary shapes in two dimensions was investigated. An on-off scheme with an adiabatic slice selective inversion pulse preceding a 2D-SSE pulse together with a segmented inward spiral excitation k-space trajectory enabled rapid free induction decay acquisitions. Performance of the sequence was evaluated in simulations, phantom experiments, and in vivo measurements at 3 T. High spatial fidelity of the excitation profile was achieved for different target shapes and with little off-resonance deterioration. Metabolite concentrations in human brain determined with the new sequence were quantified with Cramér-Rao lower bounds less than 20%. They were in the physiological range and did not deviate systematically from results acquired with a conventional SPECIAL sequence. In conclusion, a new approach for shaped voxel MRS in the human brain is presented, which complements existing sequences. Simulations show that 2D-SSE pulses yield reduced chemical shift artifact when compared with conventional localization methods. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Patrick Waxmann
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Ralf Mekle
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Florian Schubert
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Rüdiger Brühl
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Andre Kuehne
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- MR Center of Excellence, Medical University of Vienna, Vienna, Austria
| | - Tomasz D Lindel
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Frank Seifert
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Institute for Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| |
Collapse
|
5
|
Patel G, Haas M, Darji N, Speck O. Evaluation of 2D spatially selective MR spectroscopy using parallel excitation at 7 T. Quant Imaging Med Surg 2015; 5:344-55. [PMID: 26029637 PMCID: PMC4426113 DOI: 10.3978/j.issn.2223-4292.2015.03.05] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Accepted: 02/13/2015] [Indexed: 02/04/2023]
Abstract
BACKGROUND In this work, two-dimensional (2D) spatially selective magnetic resonance spectroscopy (MRS) was evaluated in both phantom and human brain using 8-channel parallel excitation (pTX) at 7 T and compared to standard STEAM. MATERIALS AND METHODS A 2D spiral excitation k-space trajectory was segmented into multiple individual segments to increase the bandwidth. pTX was used to decrease the number of segments by accelerating the trajectory. Different radio frequency (RF) shim settings were used for refocusing, water suppression and fat saturation pulses. RESULTS Phantom experiments demonstrate that, although segmented 2D excitation provided excellent spatial selectivity and spectral quality, STEAM outperformed it in terms of outer volume suppression with 0.6% RMSD compared to 1.7%, 2.5%, 3.9% and 5.5% RMSDs for acceleration factors of R=1, 2, 3 and 4, respectively. Seven major metabolites [choline (Cho), creatine (Cr), phosphocreatine (PCr), glutamate (Glu), glutamine (Gln), glutathione (GSH) and N-acetylaspartate (NAA)] were detected with sufficient accuracy [Cramér-Rao lower bounds (CRLBs) <20%] from the in vivo spectra of both methods. Conservative RF power limits resulted in reduced SNR for 2D selective MR spectra (SNR 131 and 82 for R=1 and 2, respectively) compared to the reference STEAM spectrum (SNR 199). CONCLUSIONS Single voxel spectra acquired using 2D selective MRS with and without pTX showed very good agreement with the reference STEAM spectrum. Efficient SAR management of the 2D selective MRS sequence would potentially improve the SNR of spectra.
Collapse
|
6
|
Lupulescu A, Aharon H, Frydman L. Two-dimensional RF pulses: A new approach to selectively exciting J-coupled spins in nuclear magnetic resonance. J Chem Phys 2013; 139:144204. [DOI: 10.1063/1.4823772] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
7
|
Vinding MS, Laustsen C, Maximov II, Søgaard LV, Ardenkjaer-Larsen JH, Nielsen NC. Dynamic nuclear polarization and optimal control spatial-selective 13C MRI and MRS. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 227:57-61. [PMID: 23298857 DOI: 10.1016/j.jmr.2012.12.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2012] [Revised: 11/04/2012] [Accepted: 12/04/2012] [Indexed: 06/01/2023]
Abstract
Aimed at (13)C metabolic magnetic resonance imaging (MRI) and spectroscopy (MRS) applications, we demonstrate that dynamic nuclear polarization (DNP) may be combined with optimal control 2D spatial selection to simultaneously obtain high sensitivity and well-defined spatial restriction. This is achieved through the development of spatial-selective single-shot spiral-readout MRI and MRS experiments combined with dynamic nuclear polarization hyperpolarized [1-(13)C]pyruvate on a 4.7 T pre-clinical MR scanner. The method stands out from related techniques by facilitating anatomic shaped region-of-interest (ROI) single metabolite signals available for higher image resolution or single-peak spectra. The 2D spatial-selective rf pulses were designed using a novel Krotov-based optimal control approach capable of iteratively fast providing successful pulse sequences in the absence of qualified initial guesses. The technique may be important for early detection of abnormal metabolism, monitoring disease progression, and drug research.
Collapse
Affiliation(s)
- Mads S Vinding
- Center for Insoluble Protein Structures, Interdisciplinary Nanoscience Center, Department of Chemistry, Aarhus University, Denmark
| | | | | | | | | | | |
Collapse
|
8
|
Haas M, Ullmann P, Schneider JT, Post H, Ruhm W, Hennig J, Zaitsev M. PexLoc-Parallel excitation using local encoding magnetic fields with nonlinear and nonbijective spatial profiles. Magn Reson Med 2012. [PMID: 23203228 DOI: 10.1002/mrm.24559] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
With the recent proposal of using magnetic fields that are nonlinear by design for spatial encoding, new flexibility has been introduced to MR imaging. The new degrees of freedom in shaping the spatially encoding magnetic fields (SEMs) can be used to locally adapt the imaging resolution to features of the imaged object, e.g., anatomical structures, to reduce peripheral nerve stimulation during in vivo experiments or to increase the gradient switching speed by reducing the inductance of the coils producing the SEMs and thus accelerate the imaging process. In this work, the potential of nonlinear and nonbijective SEMs for spatial encoding during transmission in multidimensional spatially selective excitation is explored. Methods for multidimensional spatially selective excitation radiofrequency pulse design based on nonlinear encoding fields are introduced, and it is shown how encoding ambiguities can be resolved using parallel transmission. In simulations and phantom experiments, the feasibility of selective excitation using nonlinear, nonbijective SEMs is demonstrated, and it is shown that the spatial resolution with which the target distribution of the transverse magnetization can be realized varies locally. Thus, the resolution of the target pattern can be increased in some regions compared with conventional linear encoding. Furthermore, experimental proof of principle of accelerated two-dimensional spatially selective excitation using nonlinear SEMs is provided in this study.
Collapse
Affiliation(s)
- M Haas
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany
| | | | | | | | | | | | | |
Collapse
|
9
|
Snyder J, Haas M, Dragonu I, Hennig J, Zaitsev M. Three-dimensional arbitrary voxel shapes in spectroscopy with submillisecond TEs. NMR IN BIOMEDICINE 2012; 25:1000-1006. [PMID: 22290622 DOI: 10.1002/nbm.2764] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2010] [Revised: 11/24/2011] [Accepted: 11/28/2011] [Indexed: 05/31/2023]
Abstract
A novel spectroscopic method for submillisecond TEs and three-dimensional arbitrarily shaped voxels was developed and applied to phantom and in vivo measurements, with additional parallel excitation (PEX) implementation. A segmented spherical shell excitation trajectory was used in combination with appropriate radiofrequency weights for target selection in three dimensions. Measurements in a two-compartment phantom realized a TE of 955 µs, excellent spectral quality and comparable signal-to-noise ratios between accelerated (R = 2) and nonaccelerated modes. The two-compartment model allowed a comparison of the spectral suppression qualities of the method and, although outer volume signals were suppressed by factors of 1434 and 2246 compared with the theoretical unsuppressed case for the clinical and PEX modes, respectively, incomplete suppression of the outer volume (935 cm(3) compared with a target volume of 5.86 cm(3) ) resulted in a spectral contamination of 10.2% and 6.5% compared with the total signal. The method was also demonstrated in vivo in human brain on a clinical system at TE = 935 µs with good signal-to-noise ratio and spatial and spectral selection, and included LCModel relative quantification analysis. Eight metabolites showed significant fitting accuracy, including aspartate, N-acetylaspartylglutamate, glutathione and glutamate.
Collapse
Affiliation(s)
- Jeff Snyder
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany.
| | | | | | | | | |
Collapse
|
10
|
Schneider JT, Kalayciyan R, Haas M, Herrmann SR, Ruhm W, Hennig J, Ullmann P. Inner-volume imaging in vivo using three-dimensional parallel spatially selective excitation. Magn Reson Med 2012; 69:1367-78. [PMID: 22730218 DOI: 10.1002/mrm.24381] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 05/24/2012] [Accepted: 05/25/2012] [Indexed: 11/09/2022]
Abstract
This work describes the first experimental realization of three-dimensional spatially selective excitation using parallel transmission in vivo. For the design of three-dimensional parallel excitation pulses with short durations and high excitation accuracy, the choice of a suitable transmit k-space trajectory is crucial. For this reason, the characteristics of a stack-of-spirals trajectory and of a concentric-shells trajectory were examined in an initial simulation study. It showed that, especially when undersampling the trajectories in combination with parallel transmission, experimental parameters such as transmit-coil geometry and off-resonance conditions have an essential impact on the suitability of the selected trajectory and undersampling scheme. Both trajectories were applied in MR inner-volume imaging experiments which demonstrate that acceptably short and robust three-dimensional selective pulses can be achieved if the trajectory is temporally optimized and its actual path is measured and considered during pulse calculation. Pulse durations as short as 3.2 ms were realized and such pulses were appropriate to accurately excite arbitrarily shaped volumes in a corn cob and in a rat in vivo. Reduced field-of-view imaging of these selectively excited targets allowed high spatial resolution and significantly reduced measurement times and furthermore demonstrates the feasibility of three-dimensional parallel excitation in realistic MRI applications in vivo.
Collapse
|