Zoelch N, Heimer J, Richter H, Luechinger R, Archibald J, Thali MJ, Gascho D. In situ temperature determination using magnetic resonance spectroscopy thermometry for noninvasive postmortem examinations. NMR IN BIOMEDICINE 2024; 37:e5171. [PMID: 38757603 DOI: 10.1002/nbm.5171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 03/28/2024] [Accepted: 04/18/2024] [Indexed: 05/18/2024]
Abstract
Magnetic resonance spectroscopy (MRS) thermometry offers a noninvasive, localized method for estimating temperature by leveraging the temperature-dependent chemical shift of water relative to a temperature-stable reference metabolite under suitable calibration. Consequentially, this technique has significant potential as a tool for postmortem MR examinations in forensic medicine and pathology. In these examinations, the deceased are examined at a wide range of body temperatures, and MRS thermometry may be used for the temperature adjustment of magnetic resonance imaging (MRI) protocols or for corrections in the analysis of MRI or MRS data. However, it is not yet clear to what extent postmortem changes may influence temperature estimation with MRS thermometry. In addition, N-acetylaspartate, which is commonly used as an in vivo reference metabolite, is known to decrease with increasing postmortem interval (PMI). This study shows that lactate, which is not only present in significant amounts postmortem but also has a temperature-stable chemical shift, can serve as a suitable reference metabolite for postmortem MRS thermometry. Using lactate, temperature estimation in postmortem brain tissue of severed sheep heads was accurate up to 60 h after death, with a mean absolute error of less than 0.5°C. For this purpose, published calibrations intended for in vivo measurements were used. Although postmortem decomposition resulted in severe metabolic changes, no consistent deviations were observed between measurements with an MR-compatible temperature probe and MRS thermometry with lactate as a reference metabolite. In addition, MRS thermometry was applied to 84 deceased who underwent a MR examination as part of the legal examination. MRS thermometry provided plausible results of brain temperature in comparison with rectal temperature. Even for deceased with a PMI well above 60 h, MRS thermometry still provided reliable readings. The results show a good suitability of MRS thermometry for postmortem examinations in forensic medicine.
Collapse
Affiliation(s)
- Niklaus Zoelch
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
- Department of Adult Psychiatry and Psychotherapy, Psychiatric University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Jakob Heimer
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Henning Richter
- Clinic of Diagnostic Imaging, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Roger Luechinger
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Jessica Archibald
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Michael J Thali
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Dominic Gascho
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Özen AC, Russe MF, Lottner T, Reiss S, Littin S, Zaitsev M, Bock M. RF-induced heating of interventional devices at 23.66 MHz. MAGMA (NEW YORK, N.Y.) 2023:10.1007/s10334-023-01099-7. [PMID: 37195365 PMCID: PMC10386938 DOI: 10.1007/s10334-023-01099-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 04/29/2023] [Accepted: 05/04/2023] [Indexed: 05/18/2023]
Abstract
OBJECTIVE Low-field MRI systems are expected to cause less RF heating in conventional interventional devices due to lower Larmor frequency. We systematically evaluate RF-induced heating of commonly used intravascular devices at the Larmor frequency of a 0.55 T system (23.66 MHz) with a focus on the effect of patient size, target organ, and device position on maximum temperature rise. MATERIALS AND METHODS To assess RF-induced heating, high-resolution measurements of the electric field, temperature, and transfer function were combined. Realistic device trajectories were derived from vascular models to evaluate the variation of the temperature increase as a function of the device trajectory. At a low-field RF test bench, the effects of patient size and positioning, target organ (liver and heart) and body coil type were measured for six commonly used interventional devices (two guidewires, two catheters, an applicator and a biopsy needle). RESULTS Electric field mapping shows that the hotspots are not necessarily localized at the device tip. Of all procedures, the liver catheterizations showed the lowest heating, and a modification of the transmit body coil could further reduce the temperature increase. For common commercial needles no significant heating was measured at the needle tip. Comparable local SAR values were found in the temperature measurements and the TF-based calculations. CONCLUSION At low fields, interventions with shorter insertion lengths such as hepatic catheterizations result in less RF-induced heating than coronary interventions. The maximum temperature increase depends on body coil design.
Collapse
Affiliation(s)
- Ali Caglar Özen
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Maximilian Frederik Russe
- Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Lottner
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Simon Reiss
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Sebastian Littin
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Maxim Zaitsev
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
3
|
Jeong H, Restivo MC, Jezzard P, Hess AT. Assessment of radio-frequency heating of a parallel transmit coil in a phantom using multi-echo proton resonance frequency shift thermometry. Magn Reson Imaging 2020; 77:57-68. [PMID: 33359425 PMCID: PMC7889491 DOI: 10.1016/j.mri.2020.12.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 11/27/2020] [Accepted: 12/20/2020] [Indexed: 10/25/2022]
Abstract
We propose a workflow for validating parallel transmission (pTx) radio-frequency (RF) magnetic field heating patterns using Proton-Resonance Frequency shift (PRF)-based MR thermometry. Electromagnetic (EM) and thermal simulations of a 7 T 8-channel dipole coil were done using commercially available software (Sim4Life) to assess RF heating. The fabrication method for a phantom with electrical properties matched to human tissue is also described, along with methods for its electrical and thermal characterisation. Energy was deposited to specific transmit channels, whilst acquiring 3D PRF data using a pair of interleaved RF shim transmit modes. A multi-echo readout and pre-scan stabilisation protocol were used for increased sensitivity and to correct for measurement-to-measurement instabilities. The electrical properties of the phantom were found to be within 10% of the intended values. Adoption of a 14-min stabilisation scan gave sufficient suppression of any evolving background spatial variation in the B0 field to achieve <0.001 °C/mm thermometry drift over 10 min of subsequent scanning. Using two RF shim transmit modes enabled full phantom coverage and combining multiple echo times enabled a 13-54% improvement in the RMSE sensitivity to temperature changes. Combining multiple echoes reduced the peak RMSE by 45% and visually reduced measurement-to-measurement instabilities. A reference fibre optic probe showed temperature deviations from the PRF-estimated temperature to be smaller than 0.5 °C. Given the importance of RF safety in pTx applications, this workflow enables accurate validation of RF heating simulations with minimal additional hardware requirements.
Collapse
Affiliation(s)
- Hongbae Jeong
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Matthew C Restivo
- Laboratory of Imaging Technology, Biochemistry and Biophysics Centre, NHLBI, NIH, Bethesda, MD, United States
| | - Peter Jezzard
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Aaron T Hess
- Centre for Clinical Magnetic Resonance Research, Department of Cardiovascular Medicine, University of Oxford, Oxford, United Kingdom; British Heart Foundation Centre for Research Excellence, Oxford, United Kingdom.
| |
Collapse
|
4
|
Özen AC, Silemek B, Lottner T, Atalar E, Bock M. MR safety watchdog for active catheters: Wireless impedance control with real-time feedback. Magn Reson Med 2020; 84:1048-1060. [PMID: 31961965 DOI: 10.1002/mrm.28153] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/29/2019] [Accepted: 12/09/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE To dynamically minimize radiofrequency (RF)-induced heating of an active catheter through an automatic change of the termination impedance. METHODS A prototype wireless module was designed that modifies the input impedance of an active catheter to keep the temperature rise during MRI below a threshold, ΔTmax . The wireless module (MR safety watchdog; MRsWD) measures the local temperature at the catheter tip using either a built-in thermistor or external data from a fiber-optical thermometer. It automatically changes the catheter input impedance until the temperature rise during MRI is minimized. If ΔTmax is exceeded, RF transmission is blocked by a feedback system. RESULTS The thermistor and fiber-optical thermometer provided consistent temperature data in a phantom experiment. During MRI, the MRsWD was able to reduce the maximum temperature rise by 25% when operated in real-time feedback mode. CONCLUSION This study demonstrates the technical feasibility of an MRsWD as an alternative or complementary approach to reduce RF-induced heating of active interventional devices. The automatic MRsWD can reduce heating using direct temperature measurements at the tip of the catheter. Given that temperature measurements are intrinsically slow, for a clinical implementation, a faster feedback parameter would be required such as the RF currents along the catheter or scattered electric fields at the tip.
Collapse
Affiliation(s)
- Ali Caglar Özen
- Department of Radiology, Medical Physics, Medical Center - University of Freiburg, Freiburg, Germany.,Faculty of Medicine, University of Freiburg, Freiburg, Germany.,German Consortium for Translational Cancer Research Partner Site Freiburg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Berk Silemek
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Thomas Lottner
- Department of Radiology, Medical Physics, Medical Center - University of Freiburg, Freiburg, Germany
| | - Ergin Atalar
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center - University of Freiburg, Freiburg, Germany
| |
Collapse
|
5
|
Erhardt JB, Lottner T, Martinez J, Özen AC, Schuettler M, Stieglitz T, Ennis DB, Bock M. It's the little things: On the complexity of planar electrode heating in MRI. Neuroimage 2019; 195:272-284. [PMID: 30935911 DOI: 10.1016/j.neuroimage.2019.03.061] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 03/07/2019] [Accepted: 03/26/2019] [Indexed: 10/27/2022] Open
Abstract
Neurological disorders are increasingly analysed and treated with implantable electrodes, and patients with such electrodes are studied with MRI despite the risk of radio-frequency (RF) induced heating during the MRI exam. Recent clinical research suggests that electrodes with smaller diameters of the electrical interface between implant and tissue are beneficial; however, the influence of this electrode contact diameter on RF-induced heating has not been investigated. In this work, electrode contact diameters between 0.3 and 4 mm of implantable electrodes appropriate for stimulation and electrocorticography were evaluated in a 1.5 T MRI system. In situ temperature measurements adapted from the ASTM standard test method were performed and complemented by simulations of the specific absorption rate (SAR) to assess local SAR values, temperature increase and the distribution of dissipated power. Measurements showed temperature changes between 0.8 K and 53 K for different electrode contact diameters, which is well above the legal limit of 1 K. Systematic errors in the temperature measurements are to be expected, as the temperature sensors may disturb the heating pattern near small electrodes. Compared to large electrodes, simulations suggest that small electrodes are subject to less dissipated power, but more localized power density. Thus, smaller electrodes might be classified as safe in current certification procedures but may be more likely to burn adjacent tissue. To assess these local heating phenomena, smaller temperature sensors or new non-invasive temperature sensing methods are needed.
Collapse
Affiliation(s)
- Johannes B Erhardt
- Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany; Department of Radiology, University of California, Los Angeles, CA, USA; BrainLinks-BrainTools, Freiburg, Germany
| | - Thomas Lottner
- Department of Radiology - Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Jessica Martinez
- Department of Radiology, University of California, Los Angeles, CA, USA; Department of Bioengineering, University of California, Los Angeles, CA, USA
| | - Ali C Özen
- Department of Radiology - Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; German Cancer Consortium Partner Site Freiburg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | - Thomas Stieglitz
- Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany; Bernstein Center Freiburg, Freiburg, Germany; BrainLinks-BrainTools, Freiburg, Germany
| | - Daniel B Ennis
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Michael Bock
- Department of Radiology - Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| |
Collapse
|
6
|
Stahl V, Maier F, Freitag MT, Floca RO, Berger MC, Umathum R, Berriel Diaz M, Herzig S, Weber MA, Dimitrakopoulou-Strauss A, Rink K, Bachert P, Ladd ME, Nagel AM. In vivoassessment of cold stimulation effects on the fat fraction of brown adipose tissue using DIXON MRI. J Magn Reson Imaging 2016; 45:369-380. [DOI: 10.1002/jmri.25364] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 06/15/2016] [Indexed: 12/13/2022] Open
Affiliation(s)
- Vanessa Stahl
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Florian Maier
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Martin T. Freitag
- Department of Radiology; German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Ralf O. Floca
- Medical and Biological Informatics, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Moritz C. Berger
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Reiner Umathum
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Mauricio Berriel Diaz
- Institute for Diabetes and Cancer IDC Helmholtz Center Munich and Joint Heidelberg-IDC Translational Diabetes Program, Inner Medicine 1, Heidelberg University Hospital; Neuherberg Germany
| | - Stephan Herzig
- Institute for Diabetes and Cancer IDC Helmholtz Center Munich and Joint Heidelberg-IDC Translational Diabetes Program, Inner Medicine 1, Heidelberg University Hospital; Neuherberg Germany
| | - Marc-André Weber
- Diagnostic and Interventional Radiology; University Hospital of Heidelberg; Heidelberg Germany
| | | | - Kristian Rink
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Peter Bachert
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Mark E. Ladd
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Armin M. Nagel
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ); Heidelberg Germany
- Department of Diagnostic and Interventional Radiology; University Medical Center Ulm; Ulm Germany
- Institute of Radiology; University Hospital Erlangen; Erlangen Germany
| |
Collapse
|
7
|
Buchenberg WB, Wassermann F, Grundmann S, Jung B, Simpson R. Acquisition of 3D temperature distributions in fluid flow using proton resonance frequency thermometry. Magn Reson Med 2015; 76:145-55. [DOI: 10.1002/mrm.25874] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Revised: 06/23/2015] [Accepted: 07/16/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Waltraud B. Buchenberg
- Department of Radiology; University Medical Center Freiburg, Medical Physics; Freiburg Germany
| | - Florian Wassermann
- Department of Fluid Mechanics and Aerodynamics; Technische Universität Darmstadt; Darmstadt Germany
| | - Sven Grundmann
- Department of Fluid Mechanics and Aerodynamics; Technische Universität Darmstadt; Darmstadt Germany
| | - Bernd Jung
- Interventional and Pediatric Radiology, University Hospital, Institute of Diagnostic; Bern Switzerland
| | - Robin Simpson
- Department of Radiology; University Medical Center Freiburg, Medical Physics; Freiburg Germany
| |
Collapse
|
8
|
Dharmadhikari S, James JR, Nyenhuis J, Bansal N. Evaluation of radiofrequency safety by high temperature resolution MR thermometry using a paramagnetic lanthanide complex. Magn Reson Med 2015; 75:2121-9. [DOI: 10.1002/mrm.25792] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2015] [Revised: 05/05/2015] [Accepted: 05/06/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Shalmali Dharmadhikari
- School of Health Sciences, Purdue University; West Lafayette Indiana USA
- Department of Radiology and Imaging Sciences; Indiana University School of Medicine; Indianapolis Indiana USA
| | - Judy R. James
- Department of Radiology; Mayo Clinic, Scottsdale; Arizona USA
| | - John Nyenhuis
- Department of Electrical and Computer Engineering; Purdue University; West Lafayette Indiana USA
| | - Navin Bansal
- Department of Radiology and Imaging Sciences; Indiana University School of Medicine; Indianapolis Indiana USA
| |
Collapse
|