Zhang HZ, Constable RT, Galiana G. Practical utilization of nonlinear spatial encoding: Fast field mapping and FRONSAC-wave. Magn Reson Med 2024. [PMID: 38651264 DOI: 10.1002/mrm.30119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/01/2024] [Accepted: 04/01/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE To study the additional value of FRONSAC encoding in 2D and 3D wave sequences, implementing a simple strategy to trajectory mapping for FRONSAC encoding gradients. THEORY AND METHODS The nonlinear gradient trajectory for each voxel was estimated by exploiting the sparsity of the point spread function in the frequency domain. Simulations and in-vivo experiments were used to analyze the performance of combinations of wave and FRONSAC encoding. RESULTS Field mapping using the simplified approach produced similar image quality with much shorter calibration time than the comprehensive mapping schemes utilized in previous work. In-vivo human brain images showed that the addition of FRONSAC encoding could improve wave image quality, particularly at very high undersampling factors and in the context of limited wave amplitudes. These results were further supported by g-factor maps. CONCLUSION Results show that FRONSAC can be used to improve image quality of wave at very high undersampling rates or in slew-limited acquisitions. Our study illustrates the potential of the proposed fast field mapping approach.
Collapse
Affiliation(s)
- Horace Z Zhang
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - R Todd Constable
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| | - Gigi Galiana
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| |
Collapse
|
2
|
Tian R, Uecker M, Davids M, Thielscher A, Buckenmaier K, Holder O, Steffen T, Scheffler K. Accelerated 2D Cartesian MRI with an 8-channel local B 0 coil array combined with parallel imaging. Magn Reson Med 2024; 91:443-465. [PMID: 37867407 DOI: 10.1002/mrm.29799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/26/2023] [Accepted: 06/30/2023] [Indexed: 10/24/2023]
Abstract
PURPOSE In MRI, the magnetization of nuclear spins is spatially encoded with linear gradients and radiofrequency receivers sensitivity profiles to produce images, which inherently leads to a long scan time. Cartesian MRI, as widely adopted for clinical scans, can be accelerated with parallel imaging and rapid magnetic field modulation during signal readout. Here, by using an 8-channel localB 0 $$ {\mathrm{B}}_0 $$ coil array, the modulation scheme optimized for sampling efficiency is investigated to speed up 2D Cartesian scans. THEORY AND METHODS An 8-channel localB 0 $$ {\mathrm{B}}_0 $$ coil array is made to carry sinusoidal currents during signal readout to accelerate 2D Cartesian scans. An MRI sampling theory based on reproducing kernel Hilbert space is exploited to visualize the efficiency of nonlinear encoding in arbitrary sampling duration. A field calibration method using current monitors for localB 0 $$ {\mathrm{B}}_0 $$ coils and the ESPIRiT algorithm is proposed to facilitate image reconstruction. Image acceleration with various modulation field shapes, aliasing control, and distinct modulation frequencies are scrutinized to find an optimized modulation scheme. A safety evaluation is conducted. In vivo 2D Cartesian scans are accelerated by the localB 0 $$ {\mathrm{B}}_0 $$ coils. RESULTS For 2D Cartesian MRI, the optimal modulation field by this localB 0 $$ {\mathrm{B}}_0 $$ array converges to a nearly linear gradient field. With the field calibration technique, it accelerates the in vivo scans (i.e., proved safe) by threefold and eightfold free of visible artifacts, without and with SENSE, respectively. CONCLUSION The nonlinear encoding analysis tool, the field calibration method, the safety evaluation procedures, and the in vivo reconstructed scans make significant steps to push MRI speed further with the localB 0 $$ {\mathrm{B}}_0 $$ coil array.
Collapse
Affiliation(s)
- Rui Tian
- High-Field MR center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Martin Uecker
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany
- BioTechMed-Graz, Graz, Austria
| | - Mathias Davids
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Axel Thielscher
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Hvidovre, Denmark
| | - Kai Buckenmaier
- High-Field MR center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Oliver Holder
- High-Field MR center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Theodor Steffen
- High-Field MR center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- High-Field MR center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
3
|
Versteeg E, Klomp DWJ, Siero JCW. Accelerating Brain Imaging Using a Silent Spatial Encoding Axis. Magn Reson Med 2022; 88:1785-1793. [PMID: 35696540 PMCID: PMC9544176 DOI: 10.1002/mrm.29350] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 05/18/2022] [Accepted: 05/18/2022] [Indexed: 11/15/2022]
Abstract
Purpose To characterize the acceleration capabilities of a silent head insert gradient axis that operates at the inaudible frequency of 20 kHz and a maximum gradient amplitude of 40 mT/m without inducing peripheral nerve stimulation. Methods The silent gradient axis' acquisitions feature an oscillating gradient in the phase‐encoding direction that is played out on top of a cartesian readout, similarly as done in Wave‐CAIPI. The additional spatial encoding fills k‐space in readout lanes allowing for the acquisition of fewer phase‐encoding steps without increasing aliasing artifacts. Fully sampled 2D gradient echo datasets were acquired both with and without the silent readout. All scans were retrospectively undersampled (acceleration factors R = 1 to 12) to compare conventional SENSE acceleration and acceleration using the silent gradient. The silent gradient amplitude and the readout bandwidth were varied to investigate the effect on artifacts and g‐factor. Results The silent readout reduced the g‐factor for all acceleration factors when compared to SENSE acceleration. Increasing the silent gradient amplitude from 31.5 mT/m to 40 mT/m at an acceleration factor of 10 yielded a reduction in the average g‐factor (gavg) from 1.3 ± 0.14 (gmax = 1.9) to 1.1 ± 0.09 (gmax = 1.6). Furthermore, reducing the number of cycles increased the readout bandwidth and the g‐factor that reached gavg = 1.5 ± 0.16 for a readout bandwidth of 651 Hz/pixel and an acceleration factor of R = 8. Conclusion A silent gradient axis enables high acceleration factors up to R = 10 while maintaining a g‐factor close to unity (gavg = 1.1 and gmax = 1.6) and can be acquired with clinically relevant readout bandwidths. Click here for author‐reader discussions
Collapse
Affiliation(s)
- Edwin Versteeg
- Department of RadiologyUniversity Medical Center Utrecht
UtrechtThe Netherlands
| | - Dennis W. J. Klomp
- Department of RadiologyUniversity Medical Center Utrecht
UtrechtThe Netherlands
| | - Jeroen C. W. Siero
- Department of RadiologyUniversity Medical Center Utrecht
UtrechtThe Netherlands
- Spinoza Center for NeuroimagingAmsterdamNetherlands
| |
Collapse
|
4
|
Glang F, Nikulin AV, Bause J, Heule R, Steffen T, Avdievich N, Scheffler K. Accelerated MRI at 9.4 T with electronically modulated time-varying receive sensitivities. Magn Reson Med 2022; 88:742-756. [PMID: 35452153 DOI: 10.1002/mrm.29245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/19/2022] [Accepted: 03/04/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE To investigate how electronically modulated time-varying receive sensitivities can improve parallel imaging reconstruction at ultra-high field. METHODS Receive sensitivity modulation was achieved by introducing PIN diodes in the receive loops, which allow rapid switching of capacitances in both arms of each loop coil and by that alter B1 - profiles, resulting in two distinct receive sensitivity configurations. A prototype 8-channel reconfigurable receive coil for human head imaging at 9.4T was built, and MR measurements were performed in both phantom and human subject. A modified SENSE reconstruction for time-varying sensitivities was formulated, and g-factor calculations were performed to investigate how modulation of receive sensitivity profiles during image encoding can improve parallel imaging reconstruction. The optimized modulation pattern was realized experimentally, and reconstructions with the time-varying sensitivities were compared with conventional static SENSE reconstructions. RESULTS The g-factor calculations showed that fast modulation of receive sensitivities in the order of the ADC dwell time during k-space acquisition can improve parallel imaging performance, as this effectively makes spatial information of both configurations simultaneously available for image encoding. This was confirmed by in vivo measurements, for which lower reconstruction errors (SSIM = 0.81 for acceleration R = 4) and g-factors (max g = 2.4; R = 4) were observed for the case of rapidly switched sensitivities compared to conventional reconstruction with static sensitivities (SSIM = 0.74 and max g = 3.2; R = 4). As the method relies on the short RF wavelength at ultra-high field, it does not yield significant benefits at 3T and below. CONCLUSIONS Time-varying receive sensitivities can be achieved by inserting PIN diodes in the receive loop coils, which allow modulation of B1 - patterns. This offers an additional degree of freedom for image encoding, with the potential for improved parallel imaging performance at ultra-high field.
Collapse
Affiliation(s)
- Felix Glang
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anton V Nikulin
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Jonas Bause
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Rahel Heule
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Theodor Steffen
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Nikolai Avdievich
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| |
Collapse
|
5
|
Darnell D, Truong TK, Song AW. Recent Advances in Radio-Frequency Coil Technologies: Flexible, Wireless, and Integrated Coil Arrays. J Magn Reson Imaging 2022; 55:1026-1042. [PMID: 34324753 PMCID: PMC10494287 DOI: 10.1002/jmri.27865] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/19/2021] [Accepted: 07/19/2021] [Indexed: 12/25/2022] Open
Abstract
Radio-frequency (RF) coils are to magnetic resonance imaging (MRI) scanners what eyes are to the human body. Because of their critical importance, there have been constant innovations driving the rapid development of RF coil technologies. Over the past four decades, the breadth and depth of the RF coil technology evolution have far exceeded the space allowed for this review article. However, these past developments have laid the very foundation on which some of the recent technical breakthroughs are built upon. Here, we narrow our focus on some of the most recent RF coil advances, specifically, on flexible, wireless, and integrated coil arrays. To provide a detailed review, we discuss the theoretical underpinnings, experimental implementations, promising results, as well as future outlooks covering these exciting topics. These recent innovations have greatly improved patient comfort and ease of scan, while also increasing the signal-to-noise ratio, image resolution, temporal throughput, and diagnostic and treatment accuracy. Together with advances in other MRI subfields, they will undoubtedly continue to drive the field forward and lead us to an ever more exciting future. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Dean Darnell
- Brain Imaging and Analysis Center, Duke University, Durham, North Carolina, USA
| | - Trong-Kha Truong
- Brain Imaging and Analysis Center, Duke University, Durham, North Carolina, USA
| | - Allen W. Song
- Brain Imaging and Analysis Center, Duke University, Durham, North Carolina, USA
| |
Collapse
|
6
|
Stockmann JP, Arango NS, Witzel T, Mareyam A, Sappo C, Zhou J, Jenkins L, Craven-Brightman L, Milshteyn E, Davids M, Hoge WS, Sliwiak M, Nasr S, Keil B, Adalsteinsson E, Guerin B, White JK, Setsompop K, Polimeni JR, Wald LL. A 31-channel integrated "AC/DC" B 0 shim and radiofrequency receive array coil for improved 7T MRI. Magn Reson Med 2022; 87:1074-1092. [PMID: 34632626 PMCID: PMC9899096 DOI: 10.1002/mrm.29022] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 08/30/2021] [Accepted: 09/04/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE To test an integrated "AC/DC" array approach at 7T, where B0 inhomogeneity poses an obstacle for functional imaging, diffusion-weighted MRI, MR spectroscopy, and other applications. METHODS A close-fitting 7T 31-channel (31-ch) brain array was constructed and tested using combined Rx and ΔB0 shim channels driven by a set of rapidly switchable current amplifiers. The coil was compared to a shape-matched 31-ch reference receive-only array for RF safety, signal-to-noise ratio (SNR), and inter-element noise correlation. We characterize the coil array's ability to provide global and dynamic (slice-optimized) shimming using ΔB0 field maps and echo planar imaging (EPI) acquisitions. RESULTS The SNR and average noise correlation were similar to the 31-ch reference array. Global and slice-optimized shimming provide 11% and 40% improvements respectively compared to baseline second-order spherical harmonic shimming. Birdcage transmit coil efficiency was similar for the reference and AC/DC array setups. CONCLUSION Adding ΔB0 shim capability to a 31-ch 7T receive array can significantly boost 7T brain B0 homogeneity without sacrificing the array's rdiofrequency performance, potentially improving ultra-high field neuroimaging applications that are vulnerable to off-resonance effects.
Collapse
Affiliation(s)
- Jason P Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Nicolas S Arango
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Thomas Witzel
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Azma Mareyam
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Charlotte Sappo
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Jiazheng Zhou
- Max-Planck Institute for Biological Cybernetics, High-Field Magnetic Resonance, Tübingen, Germany
| | - Lucas Jenkins
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Lincoln Craven-Brightman
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Eugene Milshteyn
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Mathias Davids
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - W Scott Hoge
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Monika Sliwiak
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Shahin Nasr
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Boris Keil
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Bastien Guerin
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Jacob K White
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Kawin Setsompop
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Jonathan R Polimeni
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Lawrence L Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
7
|
Versteeg E, Klomp DWJ, Siero JCW. A silent gradient axis for soundless spatial encoding to enable fast and quiet brain imaging. Magn Reson Med 2021; 87:1062-1073. [PMID: 34545956 PMCID: PMC9293127 DOI: 10.1002/mrm.29010] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/17/2021] [Accepted: 08/30/2021] [Indexed: 12/22/2022]
Abstract
Purpose A novel silent imaging method is proposed that combines a gradient insert oscillating at the inaudible frequency 20 kHz with slew rate‐limited gradient waveforms to form a silent gradient axis that enable quiet and fast imaging. Methods The gradient insert consisted of a plug‐and‐play (45 kg) single axis z‐gradient, which operated as an additional fourth gradient axis. This insert was made resonant using capacitors and combined with an audio amplifier to allow for operation at 20 kHz. The gradient field was characterized using field measurements and the physiological effects of operating a gradient field at 20 kHz were explored using peripheral nerve stimulation experiments, tissue heating simulations and sound measurements. The imaging sequence consisted of a modified gradient‐echo sequence which fills k‐space in readout lanes with a width proportional to the oscillating gradient amplitude. The feasibility of the method was demonstrated in‐vivo using 2D and 3D gradient echo (GRE) sequences which were reconstructed using a conjugate‐gradient SENSE reconstruction. Results Field measurements yielded a maximum gradient amplitude and slew rate of 40.8 mT/m and 5178T/m/s at 20 kHz. Physiological effects such as peripheral nerve stimulation and tissue heating were found not to be limiting at this amplitude and slew rate. For a 3D GRE sequence, a maximum sound level of 85 db(A) was measured during scanning. Imaging experiments using the silent gradient axis produced artifact free images while also featuring a 5.3‐fold shorter scan time than a fully sampled acquisition. Conclusion A silent gradient axis provides a novel pathway to fast and quiet brain imaging.
Collapse
Affiliation(s)
- Edwin Versteeg
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Dennis W J Klomp
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jeroen C W Siero
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.,Spinoza Center for Neuroimaging, Amsterdam, Netherlands
| |
Collapse
|
8
|
Han V, Liu C. Multiphoton magnetic resonance in imaging: A classical description and implementation. Magn Reson Med 2020; 84:1184-1197. [PMID: 32022369 DOI: 10.1002/mrm.28186] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 01/05/2020] [Accepted: 01/07/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop a classical geometric interpretation of multiphoton excitation and apply it to MRI. To investigate ways in which multiphoton excitation can enable novel imaging techniques. THEORY AND METHODS We present a fully geometric view of multiphoton excitation by taking a particular rotating frame transformation. In this rotating frame, we find that multiphoton excitations appear just like single-photon excitations again, and therefore, we can readily generalize concepts already explored in standard single-photon excitation. With a homebuilt low frequency coil, we execute a standard slice selective pulse sequence with all of its excitations replaced by their equivalent two-photon versions. In the case of no extra hardware, we use oscillating gradients as a source of extra photons for excitation. Finally, with the multiphoton interpretation of oscillating gradients, we present a novel way to transform a standard slice selective adiabatic inversion pulse into a multiband version without modifying the RF pulse itself. The addition of oscillating gradients creates multiphoton resonances at multiple spatial locations and allows for adiabatic inversions at each location. RESULTS With Bloch-Siegert shift corrections, analytical multiphoton excitation expressions match with Bloch equation simulations. Two-photon gradient-echo images of a lemon and a pork rib match with their single-photon counterparts. Frequency-offset RF combined with oscillating gradients generate excitation where the RF alone does not. CONCLUSION The multiphoton interpretation presents new flexibilities for imaging. Excitation needs not be bound to the Larmor frequency, which opens doors to RF pulse design beyond the usual filter design and the potential for further imaging innovations.
Collapse
Affiliation(s)
- Victor Han
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, California, USA
| | - Chunlei Liu
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, California, USA.,Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, California, USA
| |
Collapse
|
9
|
Aghaeifar A, Bause J, Leks E, Grodd W, Scheffler K. Dynamic B
0
shimming of the motor cortex and cerebellum with a multicoil shim setup for BOLD fMRI at 9.4T. Magn Reson Med 2019; 83:1730-1740. [DOI: 10.1002/mrm.28044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Revised: 09/20/2019] [Accepted: 09/25/2019] [Indexed: 11/11/2022]
Affiliation(s)
- Ali Aghaeifar
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- IMPRS for Cognitive and Systems Neuroscience University of Tuebingen Tuebingen Germany
| | - Jonas Bause
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- IMPRS for Cognitive and Systems Neuroscience University of Tuebingen Tuebingen Germany
- Department of Biomedical Magnetic Resonance University of Tuebingen Tuebingen Germany
| | - Edyta Leks
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- IMPRS for Cognitive and Systems Neuroscience University of Tuebingen Tuebingen Germany
- Department of Biomedical Magnetic Resonance University of Tuebingen Tuebingen Germany
| | - Wolfgang Grodd
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
| | - Klaus Scheffler
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- Department of Biomedical Magnetic Resonance University of Tuebingen Tuebingen Germany
| |
Collapse
|
10
|
Aghaeifar A, Zhou J, Heule R, Tabibian B, Schölkopf B, Jia F, Zaitsev M, Scheffler K. A 32‐channel multi‐coil setup optimized for human brain shimming at 9.4T. Magn Reson Med 2019; 83:749-764. [DOI: 10.1002/mrm.27929] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 07/11/2019] [Accepted: 07/11/2019] [Indexed: 02/04/2023]
Affiliation(s)
- Ali Aghaeifar
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- IMPRS for Cognitive and Systems Neuroscience University of Tuebingen Tuebingen Germany
| | - Jiazheng Zhou
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- IMPRS for Cognitive and Systems Neuroscience University of Tuebingen Tuebingen Germany
| | - Rahel Heule
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
| | - Behzad Tabibian
- Department of Empirical Inference Max Planck Institute for Intelligent Systems Tuebingen Germany
| | - Bernhard Schölkopf
- Department of Empirical Inference Max Planck Institute for Intelligent Systems Tuebingen Germany
| | - Feng Jia
- Department of Radiology, Medical Physics Faculty of Medicine Medical Center University of Freiburg University of Freiburg Freiburg Germany
| | - Maxim Zaitsev
- Department of Radiology, Medical Physics Faculty of Medicine Medical Center University of Freiburg University of Freiburg Freiburg Germany
| | - Klaus Scheffler
- High‐Field Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tuebingen Germany
- Department of Biomedical Magnetic Resonance University of Tuebingen Tuebingen Germany
| |
Collapse
|