1
|
Jacobson AM, Zhao X, Sommer S, Sadik F, Warden SJ, Newman C, Siegmund T, Allen MR, Surowiec RK. A comprehensive set of ultrashort echo time magnetic resonance imaging biomarkers to assess cortical bone health: A feasibility study at clinical field strength. Bone 2024; 181:117031. [PMID: 38311304 PMCID: PMC10923147 DOI: 10.1016/j.bone.2024.117031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 02/10/2024]
Abstract
INTRODUCTION Conventional bone imaging methods primarily use X-ray techniques to assess bone mineral density (BMD), focusing exclusively on the mineral phase. This approach lacks information about the organic phase and bone water content, resulting in an incomplete evaluation of bone health. Recent research highlights the potential of ultrashort echo time magnetic resonance imaging (UTE MRI) to measure cortical porosity and estimate BMD based on signal intensity. UTE MRI also provides insights into bone water distribution and matrix organization, enabling a comprehensive bone assessment with a single imaging technique. Our study aimed to establish quantifiable UTE MRI-based biomarkers at clinical field strength to estimate BMD and microarchitecture while quantifying bound water content and matrix organization. METHODS Femoral bones from 11 cadaveric specimens (n = 4 males 67-92 yrs of age, n = 7 females 70-95 yrs of age) underwent dual-echo UTE MRI (3.0 T, 0.45 mm resolution) with different echo times and high resolution peripheral quantitative computed tomography (HR-pQCT) imaging (60.7 μm voxel size). Following registration, a 4.5 mm HR-pQCT region of interest was divided into four quadrants and used across the multi-modal images. Statistical analysis involved Pearson correlation between UTE MRI porosity index and a signal-intensity technique used to estimate BMD with corresponding HR-pQCT measures. UTE MRI was used to calculate T1 relaxation time and a novel bound water index (BWI), compared across subregions using repeated measures ANOVA. RESULTS The UTE MRI-derived porosity index and signal-intensity-based estimated BMD correlated with the HR-pQCT variables (porosity: r = 0.73, p = 0.006; BMD: r = 0.79, p = 0.002). However, these correlations varied in strength when we examined each of the four quadrants (subregions, r = 0.11-0.71). T1 relaxometry and the BWI exhibited variations across the four subregions, though these differences were not statistically significant. Notably, we observed a strong negative correlation between T1 relaxation time and the BWI (r = -0.87, p = 0.0006). CONCLUSION UTE MRI shows promise for being an innocuous method for estimating cortical porosity and BMD parameters while also giving insight into bone hydration and matrix organization. This method offers the potential to equip clinicians with a more comprehensive array of imaging biomarkers to assess bone health without the need for invasive or ionizing procedures.
Collapse
Affiliation(s)
- Andrea M Jacobson
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; Dept. of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | - Xuandong Zhao
- Dept. of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA.
| | - Stefan Sommer
- Swiss Center for Musculoskeletal Imaging (SCMI), Balgrist Campus, Zurich, Switzerland; Advanced Clinical Imaging Technology (ACIT), Siemens Healthineers International AG, Zurich, Switzerland.
| | - Farhan Sadik
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA.
| | - Stuart J Warden
- Department of Physical Therapy, School of Health and Human Sciences, Indiana University Indianapolis, Indianapolis, IN, USA.
| | - Christopher Newman
- Dept. of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA.
| | - Thomas Siegmund
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA.
| | - Matthew R Allen
- Dept. of Anatomy, Physiology, and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, USA.
| | - Rachel K Surowiec
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; Dept. of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA.
| |
Collapse
|
2
|
Jerban S, Ma Y, Moazamian D, Athertya J, Dwek S, Jang H, Woods G, Chung CB, Chang EY, Du J. MRI-based porosity index (PI) and suppression ratio (SR) in the tibial cortex show significant differences between normal, osteopenic, and osteoporotic female subjects. Front Endocrinol (Lausanne) 2023; 14:1148345. [PMID: 37025410 PMCID: PMC10070867 DOI: 10.3389/fendo.2023.1148345] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/09/2023] [Indexed: 04/08/2023] Open
Abstract
Introduction Ultrashort echo time (UTE) MRI enables quantitative assessment of cortical bone. The signal ratio in dual-echo UTE imaging, known as porosity index (PI), as well as the signal ratio between UTE and inversion recovery UTE (IR-UTE) imaging, known as the suppression ratio (SR), are two rapid UTE-based bone evaluation techniques developed to reduce the time demand and cost in future clinical studies. The goal of this study was to investigate the performance of PI and SR in detecting bone quality differences between subjects with osteoporosis (OPo), osteopenia (OPe), and normal bone (Normal). Methods Tibial midshaft of fourteen OPe (72 ± 6 years old), thirty-one OPo (72 ± 6 years old), and thirty-seven Normal (36 ± 19 years old) subjects were scanned using dual-echo UTE and IR-UTE sequences on a clinical 3T scanner. Measured PI, SR, and bone thickness were compared between OPo, OPe, and normal bone (Normal) subjects using the Kruskal-Wallis test by ranks. Spearman's rank correlation coefficients were calculated between dual-energy x-ray absorptiometry (DEXA) T-score and UTE-MRI results. Results PI was significantly higher in the OPo group compared with the Normal (24.1%) and OPe (16.3%) groups. SR was significantly higher in the OPo group compared with the Normal (41.5%) and OPe (21.8%) groups. SR differences between the OPe and Normal groups were also statistically significant (16.2%). Cortical bone was significantly thinner in the OPo group compared with the Normal (22.0%) and OPe (13.0%) groups. DEXA T-scores in subjects were significantly correlated with PI (R=-0.32), SR (R=-0.50), and bone thickness (R=0.51). Discussion PI and SR, as rapid UTE-MRI-based techniques, may be useful tools to detect and monitor bone quality changes, in addition to bone morphology, in individuals affected by osteoporosis.
Collapse
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, Department of Research, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
- Department of Orthopaedic Surgery, University of California, San Diego, CA, United States
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, Department of Research, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Dina Moazamian
- Department of Radiology, University of California, San Diego, CA, United States
| | - Jiyo Athertya
- Department of Radiology, University of California, San Diego, CA, United States
| | - Sophia Dwek
- Department of Radiology, University of California, San Diego, CA, United States
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, Department of Research, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Gina Woods
- Department of Medicine, University of California, San Diego, CA, United States
| | - Christine B. Chung
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, Department of Research, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, Department of Research, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Jiang Du
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, Department of Research, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| |
Collapse
|
3
|
Lombardi AF, Ma YJ, Jang H, Jerban S, Du J, Chang EY, Chung CB. Synthetic CT in Musculoskeletal Disorders: A Systematic Review. Invest Radiol 2023; 58:43-59. [PMID: 36070535 PMCID: PMC9742139 DOI: 10.1097/rli.0000000000000916] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
ABSTRACT Repeated computed tomography (CT) examinations increase patients' ionizing radiation exposure and health costs, making an alternative method desirable. Cortical and trabecular bone, however, have short T2 relaxation times, causing low signal intensity on conventional magnetic resonance (MR) sequences. Different techniques are available to create a "CT-like" contrast of bone, such as ultrashort echo time, zero echo time, gradient-echo, and susceptibility-weighted image MR sequences, and artificial intelligence. This systematic review summarizes the essential technical background and developments of ultrashort echo time, zero echo time, gradient-echo, susceptibility-weighted image MR imaging sequences and artificial intelligence; presents studies on research and clinical applications of "CT-like" MR imaging; and describes their main advantages and limitations. We also discuss future opportunities in research, which patients would benefit the most, the most appropriate situations for using the technique, and the potential to replace CT in the clinical workflow.
Collapse
Affiliation(s)
- Alecio F Lombardi
- From the Department of Radiology, University of California San Diego, La Jolla, and the Research Service, Veterans Affairs San Diego Healthcare System, California
| | | | | | | | | | | | | |
Collapse
|
4
|
Wei Z, Jang H, Bydder GM, Yang W, Ma YJ. Fast T 1 measurement of cortical bone using 3D UTE actual flip angle imaging and single-TR acquisition (3D UTE-AFI-STR). Magn Reson Med 2021; 85:3290-3298. [PMID: 33404142 DOI: 10.1002/mrm.28655] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 12/02/2020] [Accepted: 12/03/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To describe a new method for accurate T1 measurement of cortical bone that fits the data sets of both 3D UTE actual flip angle imaging (UTE-AFI) and UTE with a single TR (UTE-STR) simultaneously (UTE-AFI-STR). THEORY AND METHODS To make both the constant values and longitudinal mapping functions in the signal equations for UTE-AFI and UTE-STR identical, the same RF pulses and flip angles were used. Therefore, there were three unknowns in the three equations. This was sufficient to fit the data. Numerical simulation as well as ex vivo and in vivo cortical bone studies were performed to validate the T1 measurement accuracy with the UTE-AFI-STR method. The original UTE-AFI variable TR (VTR) (ie, combined UTE-AFI and UTE with VTR) and simultaneous fitting (sf) of UTE-AFI and UTE-VTR (sf-UTE-AFI-VTR) methods were performed for comparison. RESULTS The numerical simulation study showed that the UTE-AFI-STR method provided accurate value of T1 when the SNR of the UTE-STR image was higher than 40. The ex vivo study showed that the UTE-AFI-STR method measured the T1 of cortical bone accurately, with difference ratios ranging from -5.0% to 0.4%. The in vivo study showed a mean T1 of 246 ms with the UTE-AFI-STR method, and mean difference ratios of 2.4% and 5.0%, respectively, compared with the other two methods. CONCLUSION The 3D UTE-AFI-STR method provides accurate mapping of the T1 of cortical bone with improved time efficiency compared with the UTE-AFI-VTR/sf-UTE-AFI-VTR methods.
Collapse
Affiliation(s)
- Zhao Wei
- Department of Radiology, University of California San Diego, San Diego, California, USA
- Institute of Electrical Engineering Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Hyungseok Jang
- Department of Radiology, University of California San Diego, San Diego, California, USA
| | - Graeme M Bydder
- Department of Radiology, University of California San Diego, San Diego, California, USA
| | - Wenhui Yang
- Institute of Electrical Engineering Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Ya-Jun Ma
- Department of Radiology, University of California San Diego, San Diego, California, USA
| |
Collapse
|
5
|
Stobbe RW, Beaulieu C. Three-dimensional Yarnball k-space acquisition for accelerated MRI. Magn Reson Med 2020; 85:1840-1854. [PMID: 33009872 DOI: 10.1002/mrm.28536] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 08/20/2020] [Accepted: 09/08/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To introduce an efficient sampling technique named Yarnball, which may serve as a direct alternative to 3D Cones. METHODS Yarnball evolves through 3D k-space with increasing loop size, and the differential equations defining this flexible trajectory are presented in detail. The sampling efficiencies of Yarnball and 3D Cones were compared through point spread function analysis and simulated imaging (which highlights undersampling in the absence of other scanning effects). The feasibility of Yarnball implementation was demonstrated for fully sampled T1 -weighted images of the human head at 3 T. RESULTS The mostly large 3D loops of the Yarnball trajectory facilitate rapid sampling under peripheral nerve stimulation constraint, an advantage that increases with readout duration (TRO ). Point spread function analysis yielded 89% (TRO = 2 ms) and 77% (TRO = 10 ms) of Yarnball voxels with magnitude less than 0.01% of the point spread function peak. For 3D Cones, these values were only 52% and 29%. The 3D-Cones technique required 1.4 times (TRO = 2 ms) and 1.8 times (TRO = 10 ms) more trajectories than Yarnball to produce simulated images of a sphere free from undersampling artifact. For a prolate spheroidal (head-like) object, 1.75 times and 2.6 times more trajectories were required for 3D Cones. Yarnball produced 0.72 mm (1/2kmax ) isotropic T1 -weighted human brain images free from undersampling artifact in only 98 seconds at 3 T. CONCLUSION Yarnball demonstrated greater k-space sampling efficiency than directly comparable 3D Cones, and may have value wherever 3D Cones has been considered. Yarnball may also have value in the context of rapid T1 -weighted brain imaging.
Collapse
Affiliation(s)
- Robert W Stobbe
- Department of Biomedical Engineering, Faculty of Medicine and Dentistry, 1098 Research Transition Facility, University of Alberta, Edmonton, Alberta, Canada
| | - Christian Beaulieu
- Department of Biomedical Engineering, Faculty of Medicine and Dentistry, 1098 Research Transition Facility, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
6
|
Ma YJ, Jerban S, Jang H, Chang D, Chang EY, Du J. Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of Bone: An Update. Front Endocrinol (Lausanne) 2020; 11:567417. [PMID: 33071975 PMCID: PMC7531487 DOI: 10.3389/fendo.2020.567417] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 08/17/2020] [Indexed: 12/24/2022] Open
Abstract
Bone possesses a highly complex hierarchical structure comprised of mineral (~45% by volume), organic matrix (~35%) and water (~20%). Water exists in bone in two forms: as bound water (BW), which is bound to bone mineral and organic matrix, or as pore water (PW), which resides in Haversian canals as well as in lacunae and canaliculi. Magnetic resonance (MR) imaging has been increasingly used for assessment of cortical and trabecular bone. However, bone appears as a signal void on conventional MR sequences because of its short T2*. Ultrashort echo time (UTE) sequences with echo times (TEs) 100-1,000 times shorter than those of conventional sequences allow direct imaging of BW and PW in bone. A series of quantitative UTE MRI techniques has been developed for bone evaluation. UTE and adiabatic inversion recovery prepared UTE (IR-UTE) sequences have been developed to quantify BW and PW. UTE magnetization transfer (UTE-MT) sequences have been developed to quantify collagen backbone protons, and UTE quantitative susceptibility mapping (UTE-QSM) sequences have been developed to assess bone mineral.
Collapse
Affiliation(s)
- Ya-Jun Ma
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| | - Douglas Chang
- Department of Orthopedic Surgery, University of California, San Diego, San Diego, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Jiang Du
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| |
Collapse
|