Meerbothe TG, Florczak S, van den Berg CAT, Levato R, Mandija S. A reusable 3D printed brain-like phantom for benchmarking electrical properties tomography reconstructions. Magn Reson Med 2024. [PMID: 38852180 DOI: 10.1002/mrm.30189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/01/2024] [Accepted: 05/21/2024] [Indexed: 06/11/2024]
Abstract
PURPOSE In MR electrical properties tomography (MR-EPT), electrical properties (EPs, conductivity and permittivity) are reconstructed from MR measurements. Phantom measurements are important to characterize the performance of MR-EPT reconstruction methods, since they allow knowledge of reference EPs values. To assess reconstruction methods in a more realistic scenario, it is important to test the methods using phantoms with realistic shapes, internal structures, and dielectric properties. In this work, we present a 3D printing procedure for the creation of realistic brain-like phantoms to benchmark MR-EPT reconstructions. METHODS We created two brain-like geometries with three different compartments using 3D printing. The first geometry was filled once, while the second geometry was filled three times with different saline-gelatin solutions, resulting in a total of four phantoms with different EPs. The saline solutions were characterized using a probe. 3D MR-EPT reconstructions were performed from MR measurements at 3T. The reconstructed conductivity values were compared to reference values of the saline-gelatin solutions. The measured fields were also compared to simulated fields using the same phantom geometry and electrical properties. RESULTS The measured fields were consistent with simulated fields. Reconstructed conductivity values were consistent with the reference (probe) conductivity values. This indicated the suitability of such phantoms for benchmarking MR-EPT reconstructions. CONCLUSION We presented a new workflow to 3D print realistic brain-like phantoms in an easy and affordable way. These phantoms are suitable to benchmark MR-EPT reconstructions, but can also be used for benchmarking other quantitative MR methods.
Collapse
Affiliation(s)
- T G Meerbothe
- Department of Radiotherapy, Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Therapy and Diagnostics, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - S Florczak
- Department of Orthopaedics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - C A T van den Berg
- Department of Radiotherapy, Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Therapy and Diagnostics, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - R Levato
- Department of Orthopaedics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands
| | - S Mandija
- Department of Radiotherapy, Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Therapy and Diagnostics, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
2
|
Fritz V, Eisele S, Martirosian P, Machann J, Schick F. A straightforward procedure to build a non-toxic relaxometry phantom with desired T1 and T2 times at 3T. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01166-7. [PMID: 38733487 DOI: 10.1007/s10334-024-01166-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 05/01/2024] [Accepted: 05/03/2024] [Indexed: 05/13/2024]
Abstract
OBJECTIVE To prepare and analyze soy-lecithin-agar gels for non-toxic relaxometry phantoms with tissue-like relaxation times at 3T. METHODS Phantoms mimicking the relaxation times of various tissues (gray and white matter, kidney cortex and medulla, spleen, muscle, liver) were built and tested with a clinical 3T whole-body MR scanner. Simple equations were derived to calculate the appropriate concentrations of soy lecithin and agar in aqueous solutions to achieve the desired relaxation times. Phantoms were tested for correspondence between measurements and calculated T1 and T2 values, reproducibility, spatial homogeneity, and temporal stability. T1 and T2 mapping techniques and a 3D T1-weighted sequence with high spatial resolution were applied. RESULTS Except for the liver relaxation phantom, all phantoms were successfully and reproducibly produced. Good agreement was found between the targeted and measured relaxation times. The percentage deviations from the targeted relaxation times were less than 3% for T1 and less than 6.5% for T2. In addition, the phantoms were homogeneous and had little to no air bubbles. However, the phantoms were unstable over time: after a storage period of 4 weeks, mold growth and also changes in relaxation times were detected in almost all phantoms. CONCLUSION Soy-lecithin-agar gels are a non-toxic material for the construction of relaxometry phantoms with tissue-like relaxation times. They are easy to prepare, inexpensive and allow independent adjustment of T1 and T2. However, there is still work to be done to improve the long-term stability of the phantoms.
Collapse
Affiliation(s)
- Victor Fritz
- Section of Experimental Radiology, Department of Diagnostic and Interventional Radiology, University of Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
- Institute for Diabetes Research and Metabolic Diseases of the Helmholtz Centre Munich at the University of Tübingen, Tübingen, Germany.
- German Center for Diabetes Research (DZD), Neuherberg, Germany.
| | - Sabine Eisele
- Section of Experimental Radiology, Department of Diagnostic and Interventional Radiology, University of Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany
| | - Petros Martirosian
- Section of Experimental Radiology, Department of Diagnostic and Interventional Radiology, University of Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany
| | - Jürgen Machann
- Section of Experimental Radiology, Department of Diagnostic and Interventional Radiology, University of Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany
- Institute for Diabetes Research and Metabolic Diseases of the Helmholtz Centre Munich at the University of Tübingen, Tübingen, Germany
- German Center for Diabetes Research (DZD), Neuherberg, Germany
| | - Fritz Schick
- Section of Experimental Radiology, Department of Diagnostic and Interventional Radiology, University of Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany
| |
Collapse
|
3
|
Malyarenko D, Ono S, Lynch TJE, Swanson SD. Technical note: hydrogel-based mimics of prostate cancer with matched relaxation, diffusion and kurtosis for validating multi-parametric MRI. Med Phys 2024; 51:3590-3596. [PMID: 38128027 PMCID: PMC11138133 DOI: 10.1002/mp.16908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/16/2023] [Accepted: 12/10/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND Protocol standardization and optimization for clinical translation of emerging quantitative multiparametric (mp)MRI biomarkers of high-risk prostate cancer requires imaging references that mimic realistic tissue value combinations for bias assessment in derived relaxation and diffusion parameters. PURPOSE This work aimed to develop a novel class of hydrogel-based synthetic materials with simultaneously controlled quantitative relaxation, diffusion, and kurtosis parameters that mimic in vivo prostate value combinations in the same spatial compartment and allow stable assemblies of adjacent structures. METHODS A set of materials with tunable T2, diffusion, and kurtosis were assembled to create quantitative biomimetic (mp)MRI references. T2 was controlled with variable agarose concentration, monoexponential diffusion by polyvinylpyrrolidone (PVP), and kurtosis by addition of lamellar vesicles. The materials were mechanically stabilized by UV cross-linked polyacrylamide gels (PAG) to allow biomimetic morphologies. The reference T2 were measured on a 3T scanner using multi-echo CPMG, and diffusion kurtosis-with multi-b DWI. RESULTS Agarose concentration controls T2 values which are nominally independent of PVP or vesicle concentration. For agarose PVP hydrogels, monoexponential diffusion values are a function of PVP concentration and independent of agarose concentration. Compared to free vesicles, for agarose-PAG combined with vesicles, diffusion was predominantly controlled by vesicles and PAG, while kurtosis was affected by agarose and vesicle concentration. Both hydrogel classes achieved image voxel parameter values (T2, Da, Ka) for relaxation (T2: 65-255 ms), apparent diffusion (Da: 0.8-1.7 μm2/ms), and kurtosis (Ka: 0.5-1.25) within the target literature ranges for normal prostate zones and cancer lesions. Relaxation and diffusion parameters remained stable for over 6 months for layered material assemblies. CONCLUSION A stable biomimetic mpMR reference based on hydrogels has been developed with a range of multi-compartment diffusion and relaxation parameter combinations observed in cancerous and healthy prostate tissue.
Collapse
Affiliation(s)
- Dariya Malyarenko
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
| | - Shigeto Ono
- Computerized Imaging Reference Systems (Sun Nuclear), Mirion Technologies Inc., Norfolk, VA 23513, USA
| | - Ted J. E. Lynch
- Computerized Imaging Reference Systems (Sun Nuclear), Mirion Technologies Inc., Norfolk, VA 23513, USA
| | - Scott D. Swanson
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
4
|
Malmberg MA, Odéen H, Hofstetter LW, Hadley JR, Parker DL. Validation of single reference variable flip angle (SR-VFA) dynamic T 1 mapping with T 2 * correction using a novel rotating phantom. Magn Reson Med 2024; 91:1419-1433. [PMID: 38115639 PMCID: PMC10872756 DOI: 10.1002/mrm.29944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 10/12/2023] [Accepted: 11/09/2023] [Indexed: 12/21/2023]
Abstract
PURPOSE To validate single reference variable flip angle (SR-VFA) dynamic T1 mapping with and without T2 * correction against inversion recovery (IR) T1 measurements. METHODS A custom cylindrical phantom with three concentric compartments was filled with variably doped agar to produce a smooth spatial gradient of the T1 relaxation rate as a function of angle across each compartment. IR T1 , VFA T1 , and B1 + measurements were made on the phantom before rotation, and multi-echo stack-of-radial dynamic images were acquired during rotation via an MRI-compatible motor. B1 + -corrected SR-VFA and SR-VFA-T2 * T1 maps were computed from the sliding window reconstructed images and compared against rotationally registered IR and VFA T1 maps to determine the percentage error. RESULTS Both VFA and SR-VFA-T2 * T1 maps fell within 10% of IR T1 measurements for a low rotational speed, with a mean accuracy of 2.3% ± 2.6% and 2.8% ± 2.6%, respectively. Increasing rotational speed was found to decrease the accuracy due to increasing temporal smoothing over ranges where the T1 change had a nonconstant slope. SR-VFA T1 mapping was found to have similar accuracy as the SR-VFA-T2 * and VFA methods at low TEs (˜<2 ms), whereas accuracy degraded strongly with later TEs. T2 * correction of the SR-VFA T1 maps was found to consistently improve accuracy and precision, especially at later TEs. CONCLUSION SR-VFA-T2 * dynamic T1 mapping was found to be accurate against reference IR T1 measurements within 10% in an agar phantom. Further validation is needed in mixed fat-water phantoms and in vivo.
Collapse
Affiliation(s)
- Michael A. Malmberg
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | | | - J. Rock Hadley
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Dennis L. Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
5
|
Li T, Wang J, Yang Y, Glide-Hurst CK, Wen N, Cai J. Multi-parametric MRI for radiotherapy simulation. Med Phys 2023; 50:5273-5293. [PMID: 36710376 PMCID: PMC10382603 DOI: 10.1002/mp.16256] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 09/10/2022] [Accepted: 12/06/2022] [Indexed: 01/31/2023] Open
Abstract
Magnetic resonance imaging (MRI) has become an important imaging modality in the field of radiotherapy (RT) in the past decade, especially with the development of various novel MRI and image-guidance techniques. In this review article, we will describe recent developments and discuss the applications of multi-parametric MRI (mpMRI) in RT simulation. In this review, mpMRI refers to a general and loose definition which includes various multi-contrast MRI techniques. Specifically, we will focus on the implementation, challenges, and future directions of mpMRI techniques for RT simulation.
Collapse
Affiliation(s)
- Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Jihong Wang
- Department of Radiation Physics, Division of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas, USA
| | - Yingli Yang
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong Univeristy School of Medicine, Shanghai, China
- SJTU-Ruijing-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Carri K Glide-Hurst
- Department of Radiation Oncology, University of Wisconsin, Madison, Wisconsin, USA
| | - Ning Wen
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong Univeristy School of Medicine, Shanghai, China
- SJTU-Ruijing-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
- The Global Institute of Future Technology, Shanghai Jiaotong University, Shanghai, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
6
|
Kraft M, Ryger S, Berman BP, Downs ME, Jordanova KV, Poorman ME, Oberdick SD, Ogier SE, Russek SE, Dagher J, Keenan KE. Towards a barrier-free anthropomorphic brain phantom for quantitative magnetic resonance imaging: Design, first construction attempt, and challenges. PLoS One 2023; 18:e0285432. [PMID: 37437022 DOI: 10.1371/journal.pone.0285432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 04/21/2023] [Indexed: 07/14/2023] Open
Abstract
Existing magnetic resonance imaging (MRI) reference objects, or phantoms, are typically constructed from simple liquid or gel solutions in containers with specific geometric configurations to enable multi-year stability. However, there is a need for phantoms that better mimic the human anatomy without barriers between the tissues. Barriers result in regions without MRI signal between the different tissue mimics, which is an artificial image artifact. We created an anatomically representative 3D structure of the brain that mimicked the T1 and T2 relaxation properties of white and gray matter at 3 T. While the goal was to avoid barriers between tissues, the 3D printed barrier between white and gray matter and other flaws in the construction were visible at 3 T. Stability measurements were made using a portable MRI system operating at 64 mT, and T2 relaxation time was stable from 0 to 22 weeks. The phantom T1 relaxation properties did change from 0 to 10 weeks; however, they did not substantially change between 10 weeks and 22 weeks. The anthropomorphic phantom used a dissolvable mold construction method to better mimic anatomy, which worked in small test objects. The construction process, though, had many challenges. We share this work with the hope that the community can build on our experience.
Collapse
Affiliation(s)
- Mikail Kraft
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
| | - Slavka Ryger
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
| | - Ben P Berman
- The MITRE Corporation, McLean, Virginia, United States of America
| | - Matthew E Downs
- The MITRE Corporation, McLean, Virginia, United States of America
| | - Kalina V Jordanova
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
| | - Megan E Poorman
- Hyperfine, Inc, Guilford, Connecticut, United States of America
| | - Samuel D Oberdick
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
- Department of Physics, University of Colorado, Boulder, Colorado, United States of America
| | - Stephen E Ogier
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
- Department of Physics, University of Colorado, Boulder, Colorado, United States of America
| | - Stephen E Russek
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
| | - Joseph Dagher
- The MITRE Corporation, McLean, Virginia, United States of America
| | - Kathryn E Keenan
- National Institute of Standards and Technology, Physical Measurement Laboratory, Boulder, Colorado, United States of America
| |
Collapse
|
7
|
Kilian D, Kilian W, Troia A, Nguyen TD, Ittermann B, Zilberti L, Gelinsky M. 3D Extrusion Printing of Biphasic Anthropomorphic Brain Phantoms Mimicking MR Relaxation Times Based on Alginate-Agarose-Carrageenan Blends. ACS APPLIED MATERIALS & INTERFACES 2022; 14:48397-48415. [PMID: 36270624 PMCID: PMC9634698 DOI: 10.1021/acsami.2c12872] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
The availability of adapted phantoms mimicking different body parts is fundamental to establishing the stability and reliability of magnetic resonance imaging (MRI) methods. The primary purpose of such phantoms is the mimicking of physiologically relevant, contrast-creating relaxation times T1 and T2. For the head, frequently examined by MRI, an anthropomorphic design of brain phantoms would imply the discrimination of gray matter and white matter (WM) within defined, spatially distributed compartments. Multichannel extrusion printing allows the layer-by-layer fabrication of multiple pastelike materials in a spatially defined manner with a predefined shape. In this study, the advantages of this method are used to fabricate biphasic brain phantoms mimicking MR relaxation times and anthropomorphic geometry. The printable ink was based on purely naturally derived polymers: alginate as a calcium-cross-linkable gelling agent, agarose, ι-carrageenan, and GdCl3 in different concentrations (0-280 μmol kg-1) as the paramagnetic component. The suggested inks (e.g., 3Alg-1Agar-6Car) fulfilled the requirements of viscoelastic behavior and printability of large constructs (>150 mL). The microstructure and distribution of GdCl3 were assessed by scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX). In closely monitored steps of technological development and characterization, from monophasic and biphasic samples as printable inks and cross-linked gels, we describe the construction of large-scale phantom models whose relaxation times were characterized and checked for stability over time.
Collapse
Affiliation(s)
- David Kilian
- Centre
for Translational Bone, Joint and Soft Tissue Research, Faculty of
Medicine Carl Gustav Carus, Technische Universität
Dresden (TUD), Dresden01307, Germany
| | - Wolfgang Kilian
- Physikalisch-Technische
Bundesanstalt (PTB), Berlin10587, Germany
| | - Adriano Troia
- Istituto
Nazionale di Ricerca Metrologica (INRiM), Turin10135, Italy
| | - Thanh-Duc Nguyen
- Centre
for Translational Bone, Joint and Soft Tissue Research, Faculty of
Medicine Carl Gustav Carus, Technische Universität
Dresden (TUD), Dresden01307, Germany
| | - Bernd Ittermann
- Physikalisch-Technische
Bundesanstalt (PTB), Berlin10587, Germany
| | - Luca Zilberti
- Istituto
Nazionale di Ricerca Metrologica (INRiM), Turin10135, Italy
| | - Michael Gelinsky
- Centre
for Translational Bone, Joint and Soft Tissue Research, Faculty of
Medicine Carl Gustav Carus, Technische Universität
Dresden (TUD), Dresden01307, Germany
| |
Collapse
|
8
|
Karakuzu A, Biswas L, Cohen-Adad J, Stikov N. Vendor-neutral sequences and fully transparent workflows improve inter-vendor reproducibility of quantitative MRI. Magn Reson Med 2022; 88:1212-1228. [PMID: 35657066 DOI: 10.1002/mrm.29292] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 04/18/2022] [Accepted: 04/19/2022] [Indexed: 12/20/2022]
Abstract
PURPOSE We developed an end-to-end workflow that starts with a vendor-neutral acquisition and tested the hypothesis that vendor-neutral sequences decrease inter-vendor variability of T1, magnetization transfer ratio (MTR), and magnetization transfer saturation-index (MTsat) measurements. METHODS We developed and deployed a vendor-neutral 3D spoiled gradient-echo (SPGR) sequence on three clinical scanners by two MRI vendors. We then acquired T1 maps on the ISMRM-NIST system phantom, as well as T1, MTR, and MTsat maps in three healthy participants. We performed hierarchical shift function analysis in vivo to characterize the differences between scanners when the vendor-neutral sequence is used instead of commercial vendor implementations. Inter-vendor deviations were compared for statistical significance to test the hypothesis. RESULTS In the phantom, the vendor-neutral sequence reduced inter-vendor differences from 8% to 19.4% to 0.2% to 5% with an overall accuracy improvement, reducing ground truth T1 deviations from 7% to 11% to 0.2% to 4%. In vivo, we found that the variability between vendors is significantly reduced (p = 0.015) for all maps (T1, MTR, and MTsat) using the vendor-neutral sequence. CONCLUSION We conclude that vendor-neutral workflows are feasible and compatible with clinical MRI scanners. The significant reduction of inter-vendor variability using vendor-neutral sequences has important implications for qMRI research and for the reliability of multicenter clinical trials.
Collapse
Affiliation(s)
- Agah Karakuzu
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, Quebec, Canada.,Montréal Heart Institute, Montréal, Quebec, Canada
| | - Labonny Biswas
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
| | - Julien Cohen-Adad
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, Quebec, Canada.,Functional Neuroimaging Unit, CRIUGM, Université de Montréal, Montréal, Quebec, Canada.,Mila - Quebec AI Institute, Montreal, Quebec, Canada
| | - Nikola Stikov
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, Quebec, Canada.,Montréal Heart Institute, Montréal, Quebec, Canada.,Center for Advanced Interdisciplinary Research, Ss. Cyril and Methodius University, Skopje, North Macedonia
| |
Collapse
|