1
|
Hopman LHGA, van Pouderoijen N, Mulder MJ, van der Laan AM, Bhagirath P, Nazarian S, Niessen HWM, Ferrari VA, Allaart CP, Götte MJW. Atrial Ablation Lesion Evaluation by Cardiac Magnetic Resonance: Review of Imaging Strategies and Histological Correlations. JACC Clin Electrophysiol 2023; 9:2665-2679. [PMID: 37737780 DOI: 10.1016/j.jacep.2023.08.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 08/09/2023] [Indexed: 09/23/2023]
Abstract
Cardiac magnetic resonance (CMR) imaging is a valuable noninvasive tool for evaluating tissue response following catheter ablation of atrial tissue. This review provides an overview of the contemporary CMR strategies to visualize atrial ablation lesions in both the acute and chronic postablation stages, focusing on their strengths and limitations. Moreover, the accuracy of CMR imaging in comparison to atrial lesion histology is discussed. T2-weighted CMR imaging is sensitive to edema and tends to overestimate lesion size in the acute stage after ablation. Noncontrast agent-enhanced T1-weighted CMR imaging has the potential to provide more accurate assessment of lesions in the acute stage but may not be as effective in the chronic stage. Late gadolinium enhancement imaging can be used to detect chronic atrial scarring, which may inform repeat ablation strategies. Moreover, novel imaging strategies are being developed, but their efficacy in characterizing atrial lesions is yet to be determined. Overall, CMR imaging has the potential to provide virtual histology that aids in evaluating the efficacy and safety of catheter ablation and monitoring of postprocedural myocardial changes. However, technical factors, scanning during arrhythmia, and transmurality assessment pose challenges. Therefore, further research is needed to develop CMR strategies to visualize the ablation lesion maturation process more effectively.
Collapse
Affiliation(s)
| | | | - Mark J Mulder
- Department of Cardiology, Amsterdam UMC, Amsterdam, the Netherlands
| | | | - Pranav Bhagirath
- Department of Cardiology, Amsterdam UMC, Amsterdam, the Netherlands
| | - Saman Nazarian
- Penn Cardiovascular Institute, Penn Heart and Vascular Center, Perelman Center for Advanced Medicine, Philadelphia, Pennsylvania, USA
| | - Hans W M Niessen
- Department of Pathology, Amsterdam UMC, Amsterdam, the Netherlands
| | - Victor A Ferrari
- Penn Cardiovascular Institute, Penn Heart and Vascular Center, Perelman Center for Advanced Medicine, Philadelphia, Pennsylvania, USA
| | | | - Marco J W Götte
- Department of Cardiology, Amsterdam UMC, Amsterdam, the Netherlands.
| |
Collapse
|
2
|
Marhabaie S, Delcey M, El Hamrani D, Vaillant F, Ginefri JC, Ozenne V, Abell E, Poirier-Quinot M, Quesson B. Remotely detuned receiver coil for high-resolution interventional cardiac magnetic resonance imaging. Front Cardiovasc Med 2023; 10:1249572. [PMID: 38028485 PMCID: PMC10643167 DOI: 10.3389/fcvm.2023.1249572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 10/03/2023] [Indexed: 12/01/2023] Open
Abstract
Introduction Interventional cardiac MRI in the context of the treatment of cardiac arrhythmia requires submillimeter image resolution to precisely characterize the cardiac substrate and guide the catheter-based ablation procedure in real-time. Conventional MRI receiver coils positioned on the thorax provide insufficient signal-to-noise ratio (SNR) and spatial selectivity to satisfy these constraints. Methods A small circular MRI receiver coil was developed and evaluated under different experimental conditions, including high-resolution MRI anatomical and thermometric imaging at 1.5 T. From the perspective of developing a therapeutic MR-compatible catheter equipped with a receiver coil, we also propose alternative remote active detuning techniques of the receiver coil using one or two cables. Theoretical details are presented, as well as simulations and experimental validation. Results Anatomical images of the left ventricle at 170 µm in-plane resolution are provided on ex vivo beating heart from swine using a 2 cm circular receiver coil. Taking advantage of the increase of SNR at its vicinity (up to 35 fold compared to conventional receiver coils), real-time MR-temperature imaging can reach an uncertainty below 0.1°C at the submillimetric spatial resolution. Remote active detuning using two cables has similar decoupling efficiency to conventional on-site decoupling, at the cost of an acceptable decrease in the resulting SNR. Discussion This study shows the potential of small dimension surface coils for minimally invasive therapy of cardiac arrhythmia intraoperatively guided by MRI. The proposed remote decoupling approaches may simplify the construction process and reduce the cost of such single-use devices.
Collapse
Affiliation(s)
- Sina Marhabaie
- Laboratoire D'Imagerie Biomédicale Multimodale Paris Saclay, Université Paris-Saclay, CNRS, Inserm, Orsay, France
| | - Marylène Delcey
- Univ. Bordeaux, INSERM, CRCTB, U 1045, IHU Liryc, Bordeaux, France
- Siemens Healthineers, Saint-Denis, France
| | | | - Fanny Vaillant
- Univ. Bordeaux, INSERM, CRCTB, U 1045, IHU Liryc, Bordeaux, France
| | - Jean-Christophe Ginefri
- Laboratoire D'Imagerie Biomédicale Multimodale Paris Saclay, Université Paris-Saclay, CNRS, Inserm, Orsay, France
| | - Valéry Ozenne
- Univ. Bordeaux, CNRS, CRMSB, UMR 5536, IHU Liryc, Bordeaux, France
| | - Emma Abell
- Univ. Bordeaux, INSERM, CRCTB, U 1045, IHU Liryc, Bordeaux, France
| | - Marie Poirier-Quinot
- Laboratoire D'Imagerie Biomédicale Multimodale Paris Saclay, Université Paris-Saclay, CNRS, Inserm, Orsay, France
| | - Bruno Quesson
- Univ. Bordeaux, CNRS, CRMSB, UMR 5536, IHU Liryc, Bordeaux, France
| |
Collapse
|
3
|
Tampakis K, Pastromas S, Sykiotis A, Kampanarou S, Kourgiannidis G, Pyrpiri C, Bousoula M, Rozakis D, Andrikopoulos G. Real-time cardiovascular magnetic resonance-guided radiofrequency ablation: A comprehensive review. World J Cardiol 2023; 15:415-426. [PMID: 37900261 PMCID: PMC10600785 DOI: 10.4330/wjc.v15.i9.415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 08/10/2023] [Accepted: 08/31/2023] [Indexed: 09/21/2023] Open
Abstract
Cardiac magnetic resonance (CMR) imaging could enable major advantages when guiding in real-time cardiac electrophysiology procedures offering high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Over the last decade, technologies and platforms for performing electrophysiology procedures in a CMR environment have been developed. However, performing procedures outside the conventional fluoroscopic laboratory posed technical, practical and safety concerns. The development of magnetic resonance imaging compatible ablation systems, the recording of high-quality electrograms despite significant electromagnetic interference and reliable methods for catheter visualization and lesion assessment are the main limiting factors. The first human reports, in order to establish a procedural workflow, have rationally focused on the relatively simple typical atrial flutter ablation and have shown that CMR-guided cavotricuspid isthmus ablation represents a valid alternative to conventional ablation. Potential expansion to other more complex arrhythmias, especially ventricular tachycardia and atrial fibrillation, would be of essential impact, taking into consideration the widespread use of substrate-based strategies. Importantly, all limitations need to be solved before application of CMR-guided ablation in a broad clinical setting.
Collapse
Affiliation(s)
- Konstantinos Tampakis
- Department of Pacing & Electrophysiology, Henry Dunant Hospital Center, Athens 11526, Greece.
| | - Sokratis Pastromas
- Department of Pacing & Electrophysiology, Henry Dunant Hospital Center, Athens 11526, Greece
| | - Alexandros Sykiotis
- Department of Pacing & Electrophysiology, Henry Dunant Hospital Center, Athens 11526, Greece
| | | | - Georgios Kourgiannidis
- Department of Pacing & Electrophysiology, Henry Dunant Hospital Center, Athens 11526, Greece
| | - Chrysa Pyrpiri
- Department of Radiology, Henry Dunant Hospital Center, Athens 11526, Greece
| | - Maria Bousoula
- Department of Anesthesiology, Henry Dunant Hospital Center, Athens 11526, Greece
| | - Dimitrios Rozakis
- Department of Anesthesiology, Henry Dunant Hospital Center, Athens 11526, Greece
| | - George Andrikopoulos
- Department of Pacing & Electrophysiology, Henry Dunant Hospital Center, Athens 11526, Greece
| |
Collapse
|