1
|
Rzagalinski I, Volmer DA. Quantification of low molecular weight compounds by MALDI imaging mass spectrometry - A tutorial review. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2016; 1865:726-739. [PMID: 28012871 DOI: 10.1016/j.bbapap.2016.12.011] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Revised: 12/01/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
Abstract
Matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry imaging (MSI) permits label-free in situ analysis of chemical compounds directly from the surface of two-dimensional biological tissue slices. It links qualitative molecular information of compounds to their spatial coordinates and distribution within the investigated tissue. MALDI-MSI can also provide the quantitative amounts of target compounds in the tissue, if proper calibration techniques are performed. Obviously, as the target molecules are embedded within the biological tissue environment and analysis must be performed at their precise locations, there is no possibility for extensive sample clean-up routines or chromatographic separations as usually performed with homogenized biological materials; ion suppression phenomena therefore become a critical side effect of MALDI-MSI. Absolute quantification by MALDI-MSI should provide an accurate value of the concentration/amount of the compound of interest in relatively small, well-defined region of interest of the examined tissue, ideally in a single pixel. This goal is extremely challenging and will not only depend on the technical possibilities and limitations of the MSI instrument hardware, but equally on the chosen calibration/standardization strategy. These strategies are the main focus of this article and are discussed and contrasted in detail in this tutorial review. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann.
Collapse
Affiliation(s)
- Ignacy Rzagalinski
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany
| | - Dietrich A Volmer
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany.
| |
Collapse
|
2
|
Buse J, Purves RW, Verrall RE, Badea I, Zhang H, Mulligan CC, Peru KM, Bailey J, Headley JV, El-Aneed A. The development and assessment of high-throughput mass spectrometry-based methods for the quantification of a nanoparticle drug delivery agent in cellular lysate. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:1171-1180. [PMID: 25395133 DOI: 10.1002/jms.3444] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Revised: 07/03/2014] [Accepted: 07/13/2014] [Indexed: 05/29/2023]
Abstract
The safe use of lipid-based drug delivery agents requires fast and sensitive qualitative and quantitative assessment of their cellular interactions. Many mass spectrometry (MS) based analytical platforms can achieve such task with varying capabilities. Therefore, four novel high-throughput MS-based quantitative methods were evaluated for the analysis of a small organic gene delivery agent: N,N-bis(dimethylhexadecyl)-1,3-propane-diammonium dibromide (G16-3). Analysis utilized MS instruments that detect analytes using low-resolution tandem MS (MS/MS) analysis (i.e. QTRAP or linear ion trap in this work) or high-resolution MS analysis (i.e. time of flight (ToF) or Orbitrap). Our results indicate that the validated fast chromatography (FC)-QTRAP-MS/MS, FC- LTQ-Orbitrap-MS, desorption electrospray ionization-collision-induced dissociation (CID)-MS/MS and matrix assisted laser desorption ionization-ToF/ToF-MS MS methods were superior in the area of method development and sample analysis time to a previously developed liquid chromatography (LC)-CID-MS/MS. To our knowledge, this is the first evaluation of the abilities of five MS-based quantitative methods that target a single pharmaceutical analyte. Our findings indicate that, in comparison to conventional LC-CID-MS/MS, the new MS-based methods resulted in a (1) substantial reduction in the analysis time, (2) reduction in the time required for method development and (3) production of either superior or comparable quantitative data. The four new high-throughput MS methods, therefore, were faster, more efficient and less expensive than a conventional LC-CID-MS/MS for the quantification of the G16-3 analyte within tissue culture. When applied to cellular lysate, no significant change in the concentration of G16-3 gemini surfactant within PAM212 cells was observed between 5 and 53 h, suggesting the absence of any metabolism/excretion from PAM212 cells.
Collapse
Affiliation(s)
- Joshua Buse
- College of Pharmacy and Nutrition, University of Saskatchewan, 110 Science Place, Saskatoon, SK, S7N 5C9, Canada
| | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Mohamed R, Guy PA. The pivotal role of mass spectrometry in determining the presence of chemical contaminants in food raw materials. MASS SPECTROMETRY REVIEWS 2011; 30:1073-1095. [PMID: 21425183 DOI: 10.1002/mas.20314] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
During recent years, a rising interest from consumers and various governmental organizations towards the quality of food has continuously been observed. Human intervention across the different stages of the food supply chain can lead to the presence of several types of chemical contaminants in food-based products. On a normal daily consumption basis, some of these chemicals are not harmful; however, for those that present a risk to consumers, legislation rules were established to specify tolerance levels or in some cases the total forbiddance of these specific contaminants. Hence, the use of appropriate analytical tools is recommended to properly identify chemical contaminants. In that context, mass spectrometry (MS)-based techniques coupled or not to chromatography offer a vast panel of features such as sensitivity, selectivity, quantification at trace levels, and/or structural elucidation. Because of the complexity of food-based matrices, sample preparation is a crucial step before final detection. In the present manuscript, we review the contribution and the potentialities of MS-based techniques to ensure the absence of chemical contaminants in food-based products.
Collapse
Affiliation(s)
- Rayane Mohamed
- Nestlé Research Center, Nestec Ltd, P.O. Box 44, Vers-Chez-Les-Blanc 1000, Lausanne 26, Switzerland
| | | |
Collapse
|
4
|
Ho YC, Tseng MC, Lu YW, Lin CC, Chen YJ, Fuh MR. Nanoparticle-assisted MALDI-TOF MS combined with seed-layer surface preparation for quantification of small molecules. Anal Chim Acta 2011; 697:1-7. [DOI: 10.1016/j.aca.2011.04.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2010] [Revised: 04/06/2011] [Accepted: 04/07/2011] [Indexed: 11/25/2022]
|
5
|
van Kampen JJA, Burgers PC, de Groot R, Gruters RA, Luider TM. Biomedical application of MALDI mass spectrometry for small-molecule analysis. MASS SPECTROMETRY REVIEWS 2011; 30:101-120. [PMID: 20169623 DOI: 10.1002/mas.20268] [Citation(s) in RCA: 114] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is an emerging analytical tool for the analysis of molecules with molar masses below 1,000 Da; that is, small molecules. This technique offers rapid analysis, high sensitivity, low sample consumption, a relative high tolerance towards salts and buffers, and the possibility to store sample on the target plate. The successful application of the technique is, however, hampered by low molecular weight (LMW) matrix-derived interference signals and by poor reproducibility of signal intensities during quantitative analyses. In this review, we focus on the biomedical application of MALDI-MS for the analysis of small molecules and discuss its favorable properties and its challenges as well as strategies to improve the performance of the technique. Furthermore, practical aspects and applications are presented.
Collapse
Affiliation(s)
- Jeroen J A van Kampen
- Laboratories of Neuro-Oncology/Clinical and Cancer Proteomics, Department of Neurology, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|
6
|
Marchese S, Perret D, Bafile E, Gentili A, Caretti F, Berardino M. Pressurized Liquid Extraction Coupled with LC–ESI–MS–MS for the Determination of Herbicides Chlormequat and Mepiquat in Flours. Chromatographia 2009. [DOI: 10.1365/s10337-009-1266-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
7
|
Kamel A, Moreira F, Almeida S, Sales M. Novel Potentiometric Sensors of Molecular Imprinted Polymers for Specific Binding of Chlormequat. ELECTROANAL 2008. [DOI: 10.1002/elan.200704039] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Amini A, Nilsson E. Quantitative analysis of polypeptide pharmaceuticals by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. J Pharm Biomed Anal 2007; 46:411-7. [PMID: 18068324 DOI: 10.1016/j.jpba.2007.10.028] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2007] [Revised: 10/15/2007] [Accepted: 10/21/2007] [Indexed: 10/22/2022]
Abstract
An accurate method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been developed for quantitative analysis of calcitonin and insulin in different commercially available pharmaceutical products. Tryptic peptides derived from these polypeptides were chemically modified at their C-terminal lysine-residues with 2-methoxy-4,5-dihydro-imidazole (light tagging) as standard and deuterated 2-methoxy-4,5-dihydro-imidazole (heavy tagging) as internal standard (IS). The heavy modified tryptic peptides (4D-Lys tag), differed by four atomic mass units from the corresponding light labelled counterparts (4H-Lys tag). The normalized peak areas (the ratio between the light and heavy tagged peptides) were used to construct a standard curve to determine the concentration of the analytes. The concentrations of calcitonin and insulin content of the analyzed pharmaceutical products were accurately determined, and less than 5% error was obtained between the present method and the manufacturer specified values. It was also found that the cysteine residues in CSNLSTCVLGK from tryptic calcitonin were converted to lanthionine by the loss of one sulfhydryl group during the labelling procedure.
Collapse
Affiliation(s)
- Ahmad Amini
- Medical Products Agency, Box 26, Dag Hammarskjölds väg 42, SE-751 03 Uppsala, Sweden.
| | | |
Collapse
|
9
|
Tian YW, Sun SH, Xie JP, Zong YL, Nie C, Guo YL. Detection of Radical Adducts with Small Molecular Weights by Matrix-Assisted Laser Desorption/Ionization with Fourier Transform Mass Spectrometry. CHINESE J CHEM 2007. [DOI: 10.1002/cjoc.200790213] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
10
|
Howard KL, Boyer GL. Quantitative analysis of cyanobacterial toxins by matrix-assisted laser desorption ionization mass spectrometry. Anal Chem 2007; 79:5980-6. [PMID: 17590013 DOI: 10.1021/ac0705723] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microcystins (MCs) are a growing problem in drinking water supplies worldwide. Common analytical techniques used to determine MC concentrations have several shortcomings, including extensive sample handling and lengthy analysis times. A simple, rapid method for quantitation of MCs by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented. Four potential internal standards were tested, including an 15N-labeled MC. For MC-LR in mixed standard solutions, a linear range of 0.11-5.0 microM (R2 = 0.98) was achieved, with a method detection limit (MDL) of 0.015 microM. Matrix effects due to extracted cell components decreased the MC-LR linear range slightly to 0.19-5.0 microM (R2 = 0.99), with MDL = 0.058 microM. Extensive analysis of possible internal standards indicates that nodularin was preferred over [15N]10-microcystin-YR or angiotensin I. The ionization efficiency and analyte-analyte suppression for four MCs of varying polarity are presented; the three polar congeners exhibited good ionization efficiency and acceptable levels of analyte-analyte suppression. These results indicate that MALDI-TOF MS represents a viable alternative for the quantitative measurement of MCs in field samples.
Collapse
Affiliation(s)
- Karen L Howard
- Department of Chemistry, State University of New York, College of Environmental Science and Forestry, 1 Forestry Drive, Syracuse, New York 13210, USA
| | | |
Collapse
|
11
|
Hurtado P, Hortal AR, Cruz-Guzmán M, Martínez-Haya B. Fragmentation and gas phase aggregation processes in the laser desorption ionization of chlorodiaminotriazines. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2007; 13:321-329. [PMID: 18192725 DOI: 10.1255/ejms.892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Fragmentation and supramolecular aggregation induced during the laser desorption/ionization (LDI) of four chlorodiaminotriazines (simazine, atrazine, terbutylazine and propazine) have been investigated. The laser wavelength employed (266 nm) lies within the first absorption band of the four triazines. The main fragmentation channel observed involves the prompt cleavage of the Cl atom, followed by partial or total fragmentation of the side alkyl chains. Breakage of the triazinic ring becomes efficient at moderate laser powers; however, the deamination of the triazine is not observed to take place. In addition, the formation of both covalent and non-covalent triazinic aggregates in the desorption plume is found to be particularly efficient. Aggregates as large as heptamers are neatly detected, with the observation that those with the most intense signal involve the dechlorinated triazinic fragment. Both aggregation and fragmentation are largely suppressed upon dilution of the triazine under matrix-assisted laser desorption/ionization conditions.
Collapse
Affiliation(s)
- Paola Hurtado
- Departamento de Sistemas Físicos Químicos y Naturales, Universidad Pablo de Olavide, 41013 Seville, Spain
| | | | | | | |
Collapse
|
12
|
Tholey A, Heinzle E. Ionic (liquid) matrices for matrix-assisted laser desorption/ionization mass spectrometry-applications and perspectives. Anal Bioanal Chem 2006; 386:24-37. [PMID: 16830111 DOI: 10.1007/s00216-006-0600-5] [Citation(s) in RCA: 233] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2006] [Revised: 06/06/2006] [Accepted: 06/07/2006] [Indexed: 11/30/2022]
Abstract
A large number of matrix substances have been used for various applications in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The majority of matrices applied in ultraviolet-MALDI MS are crystalline, low molecular weight compounds. A problem encountered with many of these matrices is the formation of hot spots, which lead to inhomogeneous samples, thus leading to increased measurement times and hampering the application of MALDI MS for quantitative purposes. Recently, ionic (liquid) matrices (ILM or IM) have been introduced as a potential alternative to the classical crystalline matrices. ILM are equimolar mixtures of conventional MALDI matrix compounds such as 2,5-dihydroxybenzoic acid (DHB), alpha-cyano-4-hydroxycinnamic acid (CCA) or sinapinic acid (SA) together with organic bases [e.g., pyridine (Py), tributylamine (TBA) or N,N-dimethylethylenediamine (DMED)]. The present article presents a first overview of this new class of matrices. Characteristic properties of ILM, their influence on mass spectrometric parameters such as sensitivity, resolution and adduct formation and their application in the fields of proteome analysis, the measurement of low molecular weight compounds, the use of MALDI MS for quantitative purposes and in MALDI imaging will be presented. Scopes and limitations for the application of ILM are discussed.
Collapse
Affiliation(s)
- Andreas Tholey
- Technische Biochemie, Geb. 1.5, Universität des Saarlandes, 66123 Saarbrücken, Germany.
| | | |
Collapse
|
13
|
Maillard LT, Guérineau V, Badet-Denisot MA, Badet B, Laprévote O, Durand P. Monitoring enzyme-catalyzed production of glucosamine-6P by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: a new enzymatic assay for glucosamine-6P synthase. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:666-72. [PMID: 16444800 DOI: 10.1002/rcm.2361] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) method for quantification of D-glucosamine-6P (GlcN-6P) that allows the kinetic study of glucosamine-6P synthase (Glms) is presented. The present report describes the optimization of the different steps of a new enzymatic assay for Glms based on in situ N-acetylation of GlcN-6P and MALDI-TOFMS analysis using N-(13C2)acetylglucosamine-6P as internal standard. Since no isotopically substituted GlcN-6P was available, the N-(13C2)acetyl derivative, easily obtained from (13C4)-acetic anhydride, was used as internal standard. Validation of the assay was achieved by measuring the fructose-6P Michaelis constant, in full agreement with reported values, and by studying the inhibition properties of arabinose-5P oxime.
Collapse
Affiliation(s)
- Ludovic T Maillard
- Institut de Chimie des Substances Naturelles, UPR 2301-CNRS, Avenue de la Terrasse, 91198 Gif-sur-Yvette, France
| | | | | | | | | | | |
Collapse
|
14
|
Sleno L, Volmer DA. Assessing the properties of internal standards for quantitative matrix-assisted laser desorption/ionization mass spectrometry of small molecules. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:1517-24. [PMID: 16628567 DOI: 10.1002/rcm.2498] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Growing interest in the ability to conduct quantitative assays for small molecules by matrix-assisted laser desorption/ionization (MALDI) has been the driving force for several recent studies. This present work includes the investigation of internal standards for these analyses using a high-repetition rate MALDI triple quadrupole instrument. Certain physicochemical properties are assessed for predicting possible matches for internal standards for different small molecules. The importance of similar molecular weight of an internal standard to its analyte is seen through experiments with a series of acylcarnitines, having a fixed charge site and growing alkyl chain length. Both acetyl- and hexanoyl-carnitine were systematically assessed with several other acylcarnitine compounds as internal standards. The results clearly demonstrate that closely matched molecular weights between analyte and internal standard are essential for acceptable quantitation results. Using alpha-cyano-4-hydroxycinnamic acid as the organic matrix, the similarities between analyte and internal standard remain the most important parameter and not necessarily their even distribution within the solid sample spot. Several 4-quinolone antibiotics as well as a diverse group of pharmaceutical drugs were tested as internal standards for the 4-quinolone, ciprofloxacin. Quantitative results were shown using the solution-phase properties, log D and pKa, of these molecules. Their distribution coefficients, log D, are demonstrated as a fundamental parameter for similar crystallization patterns of analyte and internal standard. In the end, it was also possible to quantify ciprofloxacin using a drug from a different compound class, namely quinidine, having a similar log D value as the analyte.
Collapse
Affiliation(s)
- Lekha Sleno
- Institute for Marine Biosciences, 1411 Oxford Street, Halifax, Nova Scotia, Canada B3H 3Z1
| | | |
Collapse
|
15
|
Qualitative and quantitative analysis of quaternary ammonium alkaloids from Rhizoma Corydalis by matrix-assisted laser desorption/ionization Fourier transform mass spectrometry coupled with a selective precipitation reaction using Reinecke salt. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.09.003] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
16
|
Tholey A, Zabet-Moghaddam M, Heinzle E. Quantification of Peptides for the Monitoring of Protease-Catalyzed Reactions by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Using Ionic Liquid Matrixes. Anal Chem 2006; 78:291-7. [PMID: 16383339 DOI: 10.1021/ac0514319] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Ionic liquid matrixes (ILM) have been shown to allow very homogeneous sample preparations, facilitating relative quantifications using internal standards in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). In the present work, the ability to perform quantifications of peptides without using internal standards in these matrixes was investigated. Linear correlations between peptide amount and signal intensities could be observed when increased molar matrix-to-analyte ratios were applied. The dynamic range of linearity was approximately 1 order of magnitude. The method was applied successfully to monitor the time-dependent evolution of substrates and products in trypsin-catalyzed digests of single peptides and peptide mixtures. Thus, ionic liquid matrixes allow quantitative MALDI-MS without the need for internal standards, making the method a suitable tool for the fast screening of new enzymes or the search for substrates or inhibitors.
Collapse
Affiliation(s)
- Andreas Tholey
- Technische Biochemie, Universität des Saarlandes, 66123 Saarbrücken, Germany.
| | | | | |
Collapse
|
17
|
Colgrave ML, Jones A, Craik DJ. Peptide quantification by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry: Investigations of the cyclotide kalata B1 in biological fluids. J Chromatogr A 2005; 1091:187-93. [PMID: 16395810 DOI: 10.1016/j.chroma.2005.07.094] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A rapid method has been developed for the quantification of the prototypic cyclotide kalata B1 in water and plasma utilizing matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF) mass spectrometry. The unusual structure of the cyclotides means that they do not ionise as readily as linear peptides and as a result of their low ionisation efficiency, traditional LC/MS analyses were not able to reach the levels of detection required for the quantification of cyclotides in plasma for pharmacokinetic studies. MALDI-TOF-MS analysis showed linearity (R2 > 0.99) in the concentration range 0.05-10 microg/mL with a limit of detection of 0.05 microg/mL (9 fmol) in plasma. This paper highlights the applicability of MALDI-TOF mass spectrometry for the rapid and sensitive quantification of peptides in biological samples without the need for extensive extraction procedures.
Collapse
Affiliation(s)
- Michelle L Colgrave
- Institutefor Molecular Bioscience, University of Queensland, ARC Special Research Centre for Functional and Applied Genomics, Brisbane 4072, Australia
| | | | | |
Collapse
|
18
|
Gobey J, Cole M, Janiszewski J, Covey T, Chau T, Kovarik P, Corr J. Characterization and Performance of MALDI on a Triple Quadrupole Mass Spectrometer for Analysis and Quantification of Small Molecules. Anal Chem 2005; 77:5643-54. [PMID: 16131077 DOI: 10.1021/ac0506130] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The usefulness of MALDI for small-molecule work has been limited by matrix chemical interference in the mass range of interest, tedious sample preparation, and various crystallization and sample deposition issues. We report instrument characterization and small-molecule quantification performance data from a high repetition rate laser MALDI ion source coupled to a triple quadrupole mass spectrometer. The high repetition rate laser improves sensitivity and precision and allows a proportional increase in sample throughput. Tandem mass spectrometry is used to discriminate the signal from the high chemical background caused by the MALDI matrix. Successful quantification requires use of an internal standard and a means of sample cleanup for typical in vitro sample compositions. This instrument combination and analysis technique is relatively insensitive to sample crystal quality and spot homogeneity. Quantitative performance results are characterized for 53 small-molecule pharmaceutical compounds and compared to those obtained by ESI-MS/MS. Further comparison between MALDI and ESI is examined, and the potential for high-throughput MALDI-MS/MS quantification is demonstrated.
Collapse
Affiliation(s)
- Jason Gobey
- Groton/New London Laboratories, Pfizer Global Research and Development, Eastern Point Road, Groton, Connecticut 06340, USA.
| | | | | | | | | | | | | |
Collapse
|
19
|
Zabet-Moghaddam M, Krüger R, Heinzle E, Tholey A. Matrix-assisted laser desorption/ionization mass spectrometry for the characterization of ionic liquids and the analysis of amino acids, peptides and proteins in ionic liquids. JOURNAL OF MASS SPECTROMETRY : JMS 2004; 39:1494-1505. [PMID: 15578746 DOI: 10.1002/jms.746] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Ionic liquids are interesting solvents for a number of applications in chemistry and biotechnology. We characterized five different ionic liquids by laser desorption/ionization (LDI) and by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) and studied the analysis of amino acids, peptides and proteins dissolved in these solvents. Signals of both anions and cations of the ionic liquids could be observed both in LDI- and in MALDI-MS. In the latter case, adduct formation between anions and cations of the analytes was observed. Amino acids, peptides and proteins could be analyzed in ionic liquids after addition of matrix substances. Sodium and potassium adducts were not observed in any analysis involving ionic liquids. Low molecular mass compounds and peptides could be analyzed best in the presence of water-immiscible ionic liquids, whereas proteins gave the best results in water-miscible ionic liquids. Optimal analysis conditions such as molar matrix-to-analyte and ionic liquid-to-matrix ratios were determined. Homogeneity of samples in the presence of ionic liquids was reduced compared with classical MALDI preparations. Relative quantitation of amino acids was possible using isotope-labeled internal standards. MALDI-MS thus can be used for the analysis of chemical reactions and the screening of enzyme-catalyzed reactions in ionic liquids and for the analysis of the biocatalysts dissolved in these solvents. Theoretical aspects of ion formation in the presence of ionic liquids both in LDI and MALDI analysis are discussed.
Collapse
|
20
|
Time-of-flight high resolution versus triple quadrupole tandem mass spectrometry for the analysis of quaternary ammonium herbicides in drinking water. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.08.006] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
21
|
Cui M, McCooeye MA, Fraser C, Mester Z. Quantitation of Lysergic Acid Diethylamide in Urine Using Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Ion Trap Mass Spectrometry. Anal Chem 2004; 76:7143-8. [PMID: 15571372 DOI: 10.1021/ac049285e] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A quantitative method was developed for analysis of lysergic acid diethylamide (LSD) in urine using atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry (AP MALDI-ITMS). Following solid-phase extraction of LSD from urine samples, extracts were analyzed by AP MALDI-ITMS. The identity of LSD was confirmed by fragmentation of the [M + H](+) ion using tandem mass spectrometry. The quantification of LSD was achieved using stable-isotope-labeled LSD (LSD-d(3)) as the internal standard. The [M + H](+) ion fragmented to produce a dominant fragment ion, which was used for a selected reaction monitoring (SRM) method for quantitative analysis of LSD. SRM was compared with selected ion monitoring and produced a wider linear range and lower limit of quantification. For SRM analysis of samples of LSD spiked in urine, the calibration curve was linear in the range of 1-100 ng/mL with a coefficient of determination, r(2), of 0.9917. This assay was used to determine LSD in urine samples and the AP MALDI-MS results were comparable to the HPLC/ ESI-MS results.
Collapse
Affiliation(s)
- Meng Cui
- Institute for National Measurement Standards, National Research Council of Canada, Ottawa K1A 0R6, Canada
| | | | | | | |
Collapse
|
22
|
Corpillo D, Cabella C, Geninatti Crich S, Barge A, Aime S. Detection and Quantification of Lanthanide Complexes in Cell Lysates by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. Anal Chem 2004; 76:6012-6. [PMID: 15481948 DOI: 10.1021/ac049162u] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Gadolinium (III) complexes are under intense scrutiny as contrast agents for magnetic resonance imaging. Although currently used mainly as extracellular agents, there is a growing interest to exploit their contrast enhancing ability in the intracellular environment. To ascertain the preservation of their chemical integrity upon the intracellular entrapment, it is necessary to have a method for their dosage in the cell lysates. Herein, a mass spectrometric method for detection and quantification of gadolinium complexes in cell lysates is reported. The detection by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was carried out by using a non-acidic matrix (2,4,6-trihydroxyacetophenone), which does not allow any leakage of gadolinium from the complex. Quantification has been possible by using as an internal standard an ytterbium complex with the same ligand of the analyte. Ytterbium was chosen because, among the lanthanides, it is the one with the isotopic distribution pattern the most similar to that of gadolinium. Sensitivity was enough to detect low micromolar quantities of a cationic complex and high micromolar quantities of a neutral complex in cell lysates of rat hepatoma cells. In the case of anionic complexes, sensitivity was too low for quantitative analysis. To the best of our knowledge, this is the first report concerning the quantification of metal complexes by MALDI-TOF-MS.
Collapse
Affiliation(s)
- Davide Corpillo
- Laboratorio Integrato Metodologie Avanzate, Bioindustry Park Canavese, 10010 Colleretto Giacosa, Via Ribes 5, Italy.
| | | | | | | | | |
Collapse
|
23
|
Bungert D, Heinzle E, Tholey A. Quantitative matrix-assisted laser desorption/ionization mass spectrometry for the determination of enzyme activities. Anal Biochem 2004; 326:167-75. [PMID: 15003557 DOI: 10.1016/j.ab.2003.11.013] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2003] [Indexed: 10/26/2022]
Abstract
Quantitative matrix-assisted laser desorption/ionization (MALDI) time-of-flight (ToF) mass spectrometry (MS) was applied for the determination of concentrations of low-molecular-weight (< 400Da) substrates and products of enzyme-catalyzed reactions. Isotope-labeled and fluorinated internal standards were used for the quantification. Automated quantitative MALDI-ToF MS analysis of quenched samples allowed the direct and simultaneous observation of time-dependent decrease of substrate concentration and increase of product concentration without any need for prepurification or desalting steps. The results showed good agreement with established but more elaborate analytical methods. MALDI-ToF MS thus is an interesting alternative tool for the determination of enzyme activities. Due to automated and miniaturized measurement it is especially suitable for the screening of biocatalysts.
Collapse
Affiliation(s)
- Ditte Bungert
- Technische Biochemie, Universität des Saarlandes, 66123 Saarbrücken, Germany
| | | | | |
Collapse
|
24
|
Dally JE, Gorniak J, Bowie R, Bentzley CM. Quantitation of Underivatized Free Amino Acids in Mammalian Cell Culture Media Using Matrix Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry. Anal Chem 2003; 75:5046-53. [PMID: 14708777 DOI: 10.1021/ac026243m] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this investigation, a quantitative matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) method was developed for the analysis of underivatized free amino acids in mammalian cell culture media. Calibration curves were developed for 12 amino acids over the linear range of 1-100 microM with coefficients of determination ranging from r2 = 0.9220 to r2 = 0.9973. An aerospray method was utilized for the sample deposition method, and the matrix, alpha-cyano-4-hydroxycinnamic acid, served as the internal standard. This assay was used to analyze bioreactor samples from five time points in the process. Concentrations determined through interpolation of the calibration curves were comparable to those obtained via reversed-phase HPLC based analysis with an average percent difference of 19.71%. Repeatability and intermediate precision studies were also performed, and the relative standard deviations ranged from 0.5943 to 21.41 and 3.157 to 18.97, respectively.
Collapse
Affiliation(s)
- Jennifer E Dally
- Department of Chemistry and Biochemistry, University of the Sciences in Philadelphia, Philadelphia, Pennsylvania 19104, USA.
| | | | | | | |
Collapse
|
25
|
Hatsis P, Brombacher S, Corr J, Kovarik P, Volmer DA. Quantitative analysis of small pharmaceutical drugs using a high repetition rate laser matrix-assisted laser/desorption ionization source. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2003; 17:2303-2309. [PMID: 14558130 DOI: 10.1002/rcm.1192] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In this work, a high repetition rate laser matrix-assisted laser desorption/ionization (MALDI) source is studied on a quadrupole-time-of-flight (QqTOF) and a triple quadrupole (QqQ) mass spectrometer for rapid quantification of small pharmaceutical drugs. The high repetition rate laser allows an up to 100-fold higher pulse frequency as compared with regular MALDI lasers, resulting in much larger sample throughput and number of accumulated spectra. This increases the reproducibility of signal intensities considerably, with average values being around 5% relative standard deviation after taking into account the area ratio of the analyte to an internal standard. Experiments were conducted in MS/MS mode to circumvent the large chemical background due to MALDI matrix ions in the low mass range. The dynamic range of calibration curves on the QqTOF mass spectrometer extended over at least two orders of magnitude, whereas on the QqQ it extended over at least three orders of magnitude. Detection limits ranged from 60-400 pg/microL on the QqTOF and from 6-70 pg/microL on the QqQ for a series of benzodiazepines. The benzodiazepine content of commercial pill formulations was quantified, and less than 5% error was obtained between the present method and the manufacturer's certified values. Furthermore, a high sample throughput was achieved with this method, so that a single MALDI spot could be quantitatively scanned in as little as 15 s, and an entire 96-well MALDI plate in 24 min.
Collapse
Affiliation(s)
- Panos Hatsis
- Institute for Marine Biosciences, National Research Council, 1411 Oxford Street, Halifax, Nova Scotia B3H 3Z1, Canada
| | | | | | | | | |
Collapse
|
26
|
Tholey A, Wittmann C, Kang MJ, Bungert D, Hollemeyer K, Heinzle E. Derivatization of small biomolecules for optimized matrix-assisted laser desorption/ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2002; 37:963-973. [PMID: 12271439 DOI: 10.1002/jms.355] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is a powerful tool for the measurement of low molecular mass compounds of biological interest. The limitations for this method are the volatility of many analytes, possible interference with matrix signals or bad ionization or desorption behavior of the compounds. We investigated the application of well-known and straightforward one-pot derivatization procedures to circumvent these problems. The derivatizations tested allow the measurement and the labeling of alcohols, aldehydes and ketones, carboxylic acids, alpha-ketocarboxylic acids and amines.
Collapse
Affiliation(s)
- Andreas Tholey
- Technische Biochemie, Universität des Saarlandes, 66123 Saarbrücken, Germany
| | | | | | | | | | | |
Collapse
|
27
|
Bucknall M, Fung KYC, Duncan MW. Practical quantitative biomedical applications of MALDI-TOF mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2002; 13:1015-27. [PMID: 12322949 DOI: 10.1016/s1044-0305(02)00426-9] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) is used to obtain fast and accurate determinations of molecular mass, but quantitative determinations are generally made by other techniques. In this study we illustrate the practical utility of automated MALDI-TOFMS as a tool for quantifying a diverse array of biomolecules covering an extensive molecular weight range, and present in biological extracts and fluids. Growth hormone was measured in rat pituitary tissue; insulin in human pancreatic tissue; homovanillic acid in human urine; and LVV-hemorphin-7, epinephrine and norepinephrine in human adrenal and pheochromocytoma tissues. Internal standards including compounds of similar molecular weight, structural analogs or isotopomers were incorporated into each analysis. We report on the current practical limitations of quantitative MALDI-TOFMS and highlight some of the potential benefits of this technique as a quantitative tool.
Collapse
Affiliation(s)
- Martin Bucknall
- Ray Williams Biomedical Mass Spectrometry Facility, University of New South Wales, Sydney, Australia
| | | | | |
Collapse
|
28
|
Kokko KP, Dix TA. Monitoring neurotensin[8-13] degradation in human and rat serum utilizing matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Anal Biochem 2002; 308:34-41. [PMID: 12234461 DOI: 10.1016/s0003-2697(02)00235-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A method was developed to quantify neurotensin (NT) fragment [8-13] and a novel NT[8-13] derivative, KK1, in human and rat serum utilizing matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The method allows for simultaneous quantification of the major NT[8-13] metabolite, NT[9-13] (according to molecular mass), and detection of the major KK1 metabolite, KK1M (according to molecular mass). The degradation rates of NT[8-13] and KK1 were calculated to be 24.1+/-1.0 and 193+/-8min in human serum and 5.90+/-0.22 and 153+/-4min in rat serum, respectively. The method utilizes a novel sample drying technique and spectrum acquisition protocol. In addition, an internal standard dissimilar in structure to the analytes was used. This method may be broadly applicable to the quantification of NT[8-13] and other peptide analogues of varying structure.
Collapse
Affiliation(s)
- Kyle P Kokko
- Department of Pharmaceutical Sciences, Medical University of South Carolina, 280 Calhoun Street, P.O. Box 250140, Charleston 29425-2303, USA
| | | |
Collapse
|
29
|
Riediker S, Obrist H, Varga N, Stadler RH. Determination of chlormequat and mepiquat in pear, tomato, and wheat flour using on-line solid-phase extraction (Prospekt) coupled with liquid chromatography-electrospray ionization tandem mass spectrometry. J Chromatogr A 2002; 966:15-23. [PMID: 12214689 DOI: 10.1016/s0021-9673(02)00737-9] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A sensitive and selective method is presented for the simultaneous analysis of the pesticides chlormequat and mepiquat at trace levels in tomato, pear, and wheat flour. The method entails direct injection of the food extract onto an on-line solid-phase extraction (SPE) instrument (Prospekt) using a strong cation-exchange resin. Analyte separation and detection is done by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). Surrogate standards (d9-chlormequat, d6-mepiquat) are employed to compensate for recovery losses and potential MS-MS signal suppression. The method achieves a limit of quantification for both cationic analytes at or below 5 microg/kg, and good intra- and inter-assay precision with mean variability values <7% over a concentration range up to 195 microg/kg. This study also addresses potential analyte carry-over in an SPE on-line system, as well as the robustness of the procedure and its applicability in routine quality control operations.
Collapse
Affiliation(s)
- Sonja Riediker
- Department of Quality and Safety Assurance, Nestle Research Center, Nestec Ltd, Lausanne, Switzerland
| | | | | | | |
Collapse
|
30
|
Current awareness. Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:581-588. [PMID: 11391815 DOI: 10.1002/jms.92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of mass spectrometry. Each bibliography is divided into 11 sections: 1 Books, Reviews & Symposia; 2 Instrumental Techniques & Methods; 3 Gas Phase Ion Chemistry; 4 Biology/Biochemistry: Amino Acids, Peptides & Proteins; Carbohydrates; Lipids; Nucleic Acids; 5 Pharmacology/Toxicology; 6 Natural Products; 7 Analysis of Organic Compounds; 8 Analysis of Inorganics/Organometallics; 9 Surface Analysis; 10 Environmental Analysis; 11 Elemental Analysis. Within each section, articles are listed in alphabetical order with respect to author (3 Weeks journals - Search completed at 7th. Mar. 2001)
Collapse
|
31
|
Kang MJ, Tholey A, Heinzle E. Application of automated matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the measurement of enzyme activities. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2001; 15:1327-33. [PMID: 11466793 DOI: 10.1002/rcm.376] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Sample preparation methods and data acquisition protocols were optimized for the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to high-throughput quantitative analysis of low molecular mass substrates and products of an enzyme-catalyzed reaction. Using a deuterlum-labeled internal standard, precise standard curves were obtained (r(2) = 0.9998) over two orders of magnitude of concentration of rac-1-phenylethylamine (PEA), which is converted to 2-methoxy-N-[(1R)-1-phenylethyl]acetamide (MET) by a lipase-catalyzed reaction with ethylmethoxyacetate (EMA) as second substrate. Reliable relative standard deviations were achieved (< or =5%) using automated analysis with peak intensity ratios between 0.2 and 5 of analyte to internal standard. This method permitted quantitative analysis of the lipase reaction, producing results comparable to those from gas chromatographic (GC) analysis in the dynamic range of GC. This work shows that MALDI-TOFMS can be applied for the high-throughput screening of enzymes.
Collapse
Affiliation(s)
- M J Kang
- Technische Biochemie, Saarland University, Im Stadtwald, Bldg. 2, D-66123 Saarbruecken, Germany
| | | | | |
Collapse
|