• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4591780)   Today's Articles (1340)   Subscriber (49315)
For: Curtis MA, Matassa LC, Demers R, Fegan K. Expanding the linear dynamic range in quantitative high performance liquid chromatography/tandem mass spectrometry by the use of multiple product ions. Rapid Commun Mass Spectrom 2001;15:963-968. [PMID: 11400204 DOI: 10.1002/rcm.327] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Number Cited by Other Article(s)
1
High throughput LC/ESI-MS/MS method for simultaneous analysis of 20 oral molecular-targeted anticancer drugs and the active metabolite of sunitinib in human plasma. Heliyon 2023;9:e16926. [PMID: 37484337 PMCID: PMC10360929 DOI: 10.1016/j.heliyon.2023.e16926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 05/20/2023] [Accepted: 06/01/2023] [Indexed: 07/25/2023]  Open
2
From fundamentals in calibration to modern methodologies: A tutorial for small molecules quantification in liquid chromatography-mass spectrometry bioanalysis. Anal Chim Acta 2023;1240:340711. [PMID: 36641149 DOI: 10.1016/j.aca.2022.340711] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 12/05/2022] [Accepted: 12/06/2022] [Indexed: 12/12/2022]
3
Importance of Utilizing Natural Isotopologue Transitions in Expanding the Linear Dynamic Range of LC-MS/MS Assay for Small-Molecule Pharmacokinetic Sample Analysis - A mini-review. J Pharm Sci 2021;111:1245-1249. [PMID: 34919967 PMCID: PMC9018470 DOI: 10.1016/j.xphs.2021.12.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/10/2021] [Accepted: 12/10/2021] [Indexed: 12/14/2022]
4
A Comprehensive Multi-Analyte Method for Hair Analysis: Substance-Specific Quantification Ranges and Tool for Task-Oriented Data Evaluation. J Anal Toxicol 2021;45:701-712. [PMID: 32986078 DOI: 10.1093/jat/bkaa131] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 06/09/2020] [Accepted: 09/17/2020] [Indexed: 12/14/2022]  Open
5
Development and validation of a UPLC-MS/MS method with a broad linear dynamic range for the quantification of morphine, morphine-3-glucuronide and morphine-6-glucuronide in mouse plasma and tissue homogenates. J Chromatogr B Analyt Technol Biomed Life Sci 2021;1166:122403. [PMID: 33246879 DOI: 10.1016/j.jchromb.2020.122403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/26/2020] [Accepted: 10/09/2020] [Indexed: 11/24/2022]
6
Development and validation of an LC-MS/MS method with a broad linear dynamic range for the quantification of tivozanib in human and mouse plasma, mouse tissue homogenates, and culture medium. J Chromatogr B Analyt Technol Biomed Life Sci 2019;1125:121723. [DOI: 10.1016/j.jchromb.2019.121723] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 07/09/2019] [Accepted: 07/17/2019] [Indexed: 12/17/2022]
7
Strategies and analytical workflows to extend the dynamic range in quantitative LC–MS/MS analysis. Bioanalysis 2019;11:1189-1206. [DOI: 10.4155/bio-2018-0309] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]  Open
8
Clinical Chemistry Based on Highly Accurate Separation Analysis Technology. CHROMATOGRAPHY 2018. [DOI: 10.15583/jpchrom.2018.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
9
Increasing the linear dynamic range in LC-MS: is it valid to use a less abundant isotopologue? Drug Test Anal 2017;9:1630-1636. [DOI: 10.1002/dta.2175] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 02/13/2017] [Accepted: 02/14/2017] [Indexed: 12/15/2022]
10
Expanding the Versatility of a Quantitative Determination Range Adjustment Technique Using In-Source CID in LC/MS/MS. CHROMATOGRAPHY 2017. [DOI: 10.15583/jpchrom.2017.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
11
A simultaneous determination method for 5-fluorouracil and its metabolites in human plasma with linear range adjusted by in-source collision-induced dissociation using hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry. Biomed Chromatogr 2016;30:1882-1886. [PMID: 27078498 DOI: 10.1002/bmc.3743] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Revised: 04/04/2016] [Accepted: 04/11/2016] [Indexed: 12/21/2022]
12
Potential of monitoring isotopologues by quantitative gas chromatography with time-of-flight mass spectrometry for metabolomic assay. J Sep Sci 2016;39:1137-43. [DOI: 10.1002/jssc.201501137] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Revised: 12/24/2015] [Accepted: 12/25/2015] [Indexed: 12/26/2022]
13
Shifting the Linear Range in Electrospray Ionization by In-Source Collision-Induced Dissociation. Chem Pharm Bull (Tokyo) 2016;64:356-9. [DOI: 10.1248/cpb.c15-00741] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
14
Development and validation of a dynamic range-extended LC-MS/MS multi-analyte method for 11 different postmortem matrices for redistribution studies applying solvent calibration and additional 13C isotope monitoring. Anal Bioanal Chem 2015;407:8681-712. [DOI: 10.1007/s00216-015-9023-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 08/29/2015] [Accepted: 09/01/2015] [Indexed: 11/28/2022]
15
Sample reduction strategies in discovery bioanalysis. Bioanalysis 2013;5:1691-701. [DOI: 10.4155/bio.13.133] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]  Open
16
A systematic approach for developing a robust LC–MS/MS method for bioanalysis. Bioanalysis 2013;5:91-115. [DOI: 10.4155/bio.12.295] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]  Open
17
Systematic evaluation of the root cause of non-linearity in liquid chromatography/tandem mass spectrometry bioanalytical assays and strategy to predict and extend the linear standard curve range. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2012;26:1465-1474. [PMID: 22592990 DOI: 10.1002/rcm.6252] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
18
Expanding the linear dynamic range for multiple reaction monitoring in quantitative liquid chromatography–tandem mass spectrometry utilizing natural isotopologue transitions. Talanta 2011;87:307-10. [DOI: 10.1016/j.talanta.2011.09.063] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2011] [Revised: 09/27/2011] [Accepted: 09/28/2011] [Indexed: 11/25/2022]
19
Use of a variably sensitive selected reaction monitoring method to extend the linear dynamic range for quantitative high-performance liquid chromatography/tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007;21:369-74. [PMID: 17206741 DOI: 10.1002/rcm.2856] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
20
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001;36:1076-1082. [PMID: 11599087 DOI: 10.1002/jms.96] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA