1
|
Yang J, Yu X, Zhang Z, Xu R, Wu F, Wang T, Liu Y, Ouyang J, Deng F. Surface modification of titanium manufactured through selective laser melting inhibited osteoclast differentiation through mitogen-activated protein kinase signaling pathway. J Biomater Appl 2020; 35:169-181. [PMID: 32340522 DOI: 10.1177/0885328220920457] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Selective laser melting used in manufacturing custom-made titanium implants becomes more popular. In view of the important role played by osteoclasts in peri-implant bone resorption and osseointegration, we modified selective laser melting-manufactured titanium surfaces using sandblasting/alkali-heating and sandblasting/acid-etching, and investigated their effect on osteoclast differentiation as well as their underlying mechanisms. The properties of the surfaces, including elements, roughness, wettability and topography, were analyzed. We evaluated the proliferation and morphology of primary mouse bone marrow-derived monocytes, as well as induced osteoclasts derived from bone marrow-derived monocytes, on samples. Then, osteoclast differentiation was determined by the tartrate-resistant acid phosphatase activity assay, calcitonin receptors immunofluorescence staining and the expression of osteoclast-related genes. The results showed that sandblasting/alkali-heating established nanonet structure with the lowest water contact angle, and both sandblasting/alkali-heating and sandblasting/acid-etching significantly decreased surface roughness and heterogeneity compared with selective laser melting. Surface modifications of selective laser melting-produced titanium altered bone marrow-derived monocyte morphology and suppressed bone marrow-derived monocyte proliferation and osteoclastogenesis in vitro (sandblasting/alkali-heating>sandblasting/acid-etching>selective laser melting). These surface modifications reduced the activation of extracellular signal-regulated kinase and c-Jun N-terminal kinases compared to native-selective laser melting. Sandblasting/alkali-heating additionally blocked tumor necrosis factor receptor-associated factor 6 recruitment. The results suggested that sandblasting/alkali-heating and sandblasting/acid-etching modifications on selective laser melting titanium could inhibit osteoclast differentiation through suppressing extracellular signal-regulated kinase and c-Jun N-terminal kinase phosphorylation in mitogen-activated protein kinase signaling pathway and provide a promising technique which might reduce peri-implant bone resorption for optimizing native-selective laser melting implants.
Collapse
Affiliation(s)
- Jiamin Yang
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Xiaolin Yu
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Zhengchuan Zhang
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Ruogu Xu
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Fan Wu
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Tianlu Wang
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Yun Liu
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| | - Jianglin Ouyang
- Guangzhou Institute of Advanced Technology, Chinese Academy of Science, Guangzhou, PR China.,Guangzhou Janus Biotechnology Co., Ltd, Chinese Academy of Sciences, Guangzhou, PR China
| | - Feilong Deng
- Department of Oral Implantology, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, PR China
| |
Collapse
|
2
|
Canabarro A, Paiva CG, Ferreira HT, Tholt-de-Vasconcellos B, De-Deus G, Prioli R, Linhares ABR, Alves GG, Granjeiro JM. Short-term response of human osteoblast-like cells on titanium surfaces with micro- and nano-sized features. SCANNING 2012; 34:378-386. [PMID: 22753315 DOI: 10.1002/sca.21020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Accepted: 02/09/2012] [Indexed: 06/01/2023]
Abstract
Since the way that human bone cells behave on contact with different surfaces topographies seems to be crucial to osseointegration, the aim of the present study is to evaluate the participation of some micro- and nanosized features of Ti surfaces in the short-term response of primary human osteoblast-like cells (HOC). Surfaces were prepared as ground (G-Ti), hydrofluoric acid etched (HF-Ti), and sandblasted/HF-etched (SLA-Ti), and analyzed using both three-dimensional (3D) profilometer and atomic force microscope (AFM). Cell morphology was assessed using scanning electron microscopy (SEM) after 4 and 24 h in culture. Cell viability, adhesion, and spreading were also evaluated 4 and 24 h after seeding over each surface. Data were compared by analysis of variance (ANOVA) complemented by Duncan test. Cell morphology, cell counting, and membrane integrity (Neutral Red, NR) were not affected by surface treatment at any time. However, HF-Ti presented the smallest surface area and did not increase tetrazolium hydroxide (XTT) reduction from 4 to 24 h. On the other hand, a higher level of spreading was only found on the rougher and isotropic SLA-Ti at 4 h. In conclusion, although all evaluated Ti surfaces allowed HOC short-term adhesion, the finer topography introduced by HF as single treatment did not favor HOC mitochondrial activity and spreading. The rougher and more complex SLA surface seems to provide a better substrate for HOC short-term response.
Collapse
Affiliation(s)
- Antonio Canabarro
- Department of Implantology, Veiga de Almeida University, Rio de Janeiro, Brazil.
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Osorio E, Aguilera FS, Osorio R, García-Godoy F, Cabrerizo-Vilchez MA, Toledano M. Determining efficacy of monitoring devices on ceramic bond to resin composite. Med Oral Patol Oral Cir Bucal 2012; 17:e833-40. [PMID: 22549693 PMCID: PMC3482530 DOI: 10.4317/medoral.18200] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2012] [Accepted: 03/11/2012] [Indexed: 11/20/2022] Open
Abstract
Objectives: This paper aims to assess the effectiveness of 3D nanoroughness and 2D microroughness evaluations, by their correlation with contact angle measurements and shear bond strength test, in order to evaluate the effect of two different acids conditioning on the bonding efficacy of a leucite-based glass-ceramic to a composite resin.
Study Design: Ceramic (IPS Empress) blocks were treated as follows: 1) no treatment, 2) 37% phosphoric acid (H3PO4), 15 s, 3) 9% hydrofluoric acid (HF), 5 min. Micro- and nano-roughness were assessed with a profilometer and by means of an atomic force microscopy (AFM). Water contact angle (CA) measurements were determined to assess wettability of the ceramic surfaces with the asixymetric drop shape analysis contact diameter technique. Shear bond strength (SBS) was tested to a resin composite (Z100) with three different adhesive systems (Scotchbond Multipurpose Plus, Clearfil New Bond, ProBOND). Scanning electron microscopy (SEM) images were performed.
Results: Nanoroughness values assessed in 50x50 μm areas were higher for the HF group, these differences were not detected by profilometric analysis. HF treatment created the nano- roughest surfaces and the smallest CA (p<0.05), producing the highest SBS to the composite resin with all tested adhesive systems (p<0.05). No differences existed between the SBS produced by the adhesive systems evaluated with any of the surface treatments tested.
Conclusions: Nano-roughness obtained in a 50x50 µm scan size areas was the most reliable data to evaluate the topographical changes produced by the different acid treatments on ceramic surfaces.
Key words:Dental ceramic, acid etching, bonding efficacy, resin composite, adhesive systems, contact angle, roughness.
Collapse
Affiliation(s)
- Estrella Osorio
- Department of Dental Materials, School of Dentistry, University of Granada, Avda. de las Fuerzas Armadas 1, 1B, 18014 Granada, Spain
| | | | | | | | | | | |
Collapse
|