1
|
Nair AS, Viannie LR. Piezoelectric barium titanate/hydroxyapatite composite coatings on Ti-6Al-4V alloy via electrophoretic deposition. Heliyon 2024; 10:e39102. [PMID: 39640757 PMCID: PMC11620139 DOI: 10.1016/j.heliyon.2024.e39102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 09/05/2024] [Accepted: 10/07/2024] [Indexed: 12/07/2024] Open
Abstract
Electrophoretic deposition (EPD) is a widely accepted, cost-effective and simple method to obtain conformal coatings of dense nanoparticles via application of a DC voltage. This paper reports the physical and mechanical properties of nanostructured barium titanate/hydroxyapatite (BT/HA) ceramic composites coated onto Ti-6Al-4V alloy via cathodic EPD in various ratios of 40:60, 50:50 and 60:40 (HB4, HB5 and HB6) respectively. Homogenous BT/HA coatings were obtained at a notably low voltage of 10 V. The crystallinity and phase analysis confirmed the formation of tetragonal phase of BT indicating the piezoelectric property. HB6 exhibits maximum piezoelectric coefficient (d33) of 159 pC/N and Vicker's hardness of 242.31 HV. The cross-sectional electron micrographs show well connected and homogeneous coatings with increasing amounts of BT. Human mesenchymal stem cell lines were utilized in biocompatibility experiments, which revealed that HB composites had greater viability of HW-MSCs cells than pure BT, with HB6 exhibiting a maximum cell viability of more than 90 %.
Collapse
Affiliation(s)
- Akhila S Nair
- Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, 632 014, Tamil Nadu, India
| | - Leema Rose Viannie
- Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, 632 014, Tamil Nadu, India
| |
Collapse
|
2
|
Ali A, Chowdhury S, Janorkar A, Marquart M, Griggs JA, Bumgardner J, Roach MD. A novel single-step anodization approach for PANI-doping oxide surfaces to improve the photocatalytic activity of titanium implants. Biomed Mater 2022; 18:015010. [PMID: 36384042 DOI: 10.1088/1748-605x/aca37d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Crystalline titanium oxides have shown photocatalytic activity (PCA) and the formation of antibacterial reactive oxygen species (ROS) when stimulated with UV light. Polyaniline (PANI) is a conductive polymer that has shown antibacterial effects. Previously, titanium oxides have been PANI-doped using a multi-step approach. In the present study, we compared PANI-doped specimens produced with a two-step method (ACV), to PANI-doped specimens produced by a novel single-step direct anodization (AAn) method, and a control group of anodized un-doped specimens. The surface morphology, oxide crystallinity, surface elemental composition, surface roughness, surface wettability, oxide adhesion, corrosion resistance, PCA, and ROS generation of each oxide group were evaluated. All groups exhibited mixed anatase and rutile phase oxides. The AAn group revealed less anatase and rutile, but more PANI-surface coverage. The AAn group exhibited significantly increased PCA after 60 minutes of direct UVA illumination compared to the ACV group, despite containing lower amounts of anatase and rutile. The ACV and AAn groups showed significant increases in ROS production after 4 hours UVA illumination while the control group showed similar ROS production. These findings suggested that PANI doping using the novel direct anodization technique significantly improved PCA even for oxides containing less crystallinity. The S. aureus attachment response to each oxide group was also compared under UVA pre-illumination, UVA direct illumination, and no illumination (dark) lighting conditions. Although no significant differences were shown in the bacterial response, both PANI-doped groups exhibited less average bacterial attachment compared to the control group. The response of MC3T3-E1 pre-osteoblast cells to each oxide group was evaluated using MTT and live/dead assays, and no evidence of cytotoxicity was found. Since many, if not most, titanium implant devices are routinely anodized as a part of the manufacturing processes, these study findings are applicable to a wide variety of implant applications.
Collapse
Affiliation(s)
- Aya Ali
- Department of Biomedical Materials Science, D528, The University of Mississippi Medical Center, 2500 North State Street, Jackson, Mississippi, 39216-4505, UNITED STATES
| | - Sheetal Chowdhury
- Department of Biomedical Materials Science, D528, The University of Mississippi Medical Center, 2500 North State Street, Jackson, Mississippi, 39216-4505, UNITED STATES
| | - Amol Janorkar
- Department of Biomedical Materials Science, D528, The University of Mississippi Medical Center, School of Dentistry, 2500 North State Street, Jackson, Mississippi, 39216-4505, UNITED STATES
| | - Mary Marquart
- Department of Microbiology and Immunology, The University of Mississippi Medical Center, 2500 North State Street, Jackson, Mississippi, 39216-4505, UNITED STATES
| | - Jason A Griggs
- Department of Biomedical Materials Science, D528, The University of Mississippi Medical Center, School of Dentistry, 2500 North State Street, Jackson, Mississippi, 39216-4505, UNITED STATES
| | - Joel Bumgardner
- Biomedical Engineering Department, The University of Memphis Herff College of Engineering, Engineering Technology Building, 330, Memphis, Tennessee, 38152, UNITED STATES
| | - Michael D Roach
- Department of Biomedical Materials Science, D528, The University of Mississippi Medical Center, 2500 North State Street, School of Dentistry, Jackson, Mississippi, 39216, UNITED STATES
| |
Collapse
|
3
|
Beta-Titanium Alloy Covered by Ferroelectric Coating–Physicochemical Properties and Human Osteoblast-Like Cell Response. COATINGS 2021. [DOI: 10.3390/coatings11020210] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Beta-titanium alloys are promising materials for bone implants due to their advantageous mechanical properties. For enhancing the interaction of bone cells with this perspective material, we developed a ferroelectric barium titanate (BaTiO3) coating on a Ti39Nb alloy by hydrothermal synthesis. This coating was analyzed by scanning electron and Raman microscopy, X-ray diffraction, piezoresponse force microscopy, X-ray photoelectron spectroscopy, nanoindentation, and roughness measurement. Leaching experiments in a saline solution revealed that Ba is released from the coating. A progressive decrease of Ba concentration in the material was also found after 1, 3, and 7 days of cultivation of human osteoblast-like Saos-2 cells. On day 1, the Saos-2 cells adhered on the BaTiO3 film in higher initial numbers than on the bare alloy, but they were less spread, and their initial proliferation rate was slower. These cells also contained a lower amount of beta1-integrins and vinculin, i.e., molecules involved in cell adhesion, and produced a lower amount of collagen I. This cell behavior was attributed to a higher surface roughness of BaTiO3 film rather than to its potential cytotoxicity, because the cell viability on this film was very high, reaching almost 99%. The amount of alkaline phosphatase, an enzyme involved in bone matrix mineralization, was similar in cells on the BaTiO3-coated and uncoated alloy, and on day 7, the cells on BaTiO3 film attained a higher final cell population density. These results indicate that after some improvements, particularly in its roughness and stability, the hydrothermal ferroelectric BaTiO3 film could be promising coating for improved osseointegration of bone implants.
Collapse
|
4
|
İzmir M, Tufan Y, Tan G, Ercan B. Ti6Al4V foams having nanotubular surfaces for orthopaedic applications. SURF INTERFACE ANAL 2019. [DOI: 10.1002/sia.6687] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Merve İzmir
- Department of Metallurgical and Materials EngineeringMiddle East Technical University Çankaya, Ankara Turkey
| | - Yiğithan Tufan
- Department of Metallurgical and Materials EngineeringMiddle East Technical University Çankaya, Ankara Turkey
| | - Güher Tan
- Department of Metallurgical and Materials EngineeringMersin University Mersin Turkey
| | - Batur Ercan
- Department of Metallurgical and Materials EngineeringMiddle East Technical University Çankaya, Ankara Turkey
- Biomedical Engineering ProgramMiddle East Technical University Ankara Turkey
- BIOMATEN, METU Center of Excellence in Biomaterials and Tissue EngineeringMiddle East Technical University Ankara Turkey
| |
Collapse
|