1
|
Sun H, Wu A, Lu M, Cao S. Liability, risks, and recommendations for ultrasound use in the diagnosis of obstetrics diseases. Heliyon 2023; 9:e21829. [PMID: 38045126 PMCID: PMC10692788 DOI: 10.1016/j.heliyon.2023.e21829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Revised: 10/27/2023] [Accepted: 10/30/2023] [Indexed: 12/05/2023] Open
Abstract
This literature review will summarize the liability issues, risks, and ultrasound recommendations for diagnosing obstetrics diseases. One liability issue is related to misdiagnosis or failure to detect abnormalities during an ultrasound examination. Ultrasound images can be subjective interpretations, and errors may occur due to factors such as operator skill, equipment limitations, or fetal positioning. Another liability concern is related to the potential adverse effects of ultrasound exposure on both the mother and fetus. While extensive research has shown that diagnostic ultrasound is generally safe when used appropriately, there are still uncertainties regarding long-term effects. Some studies suggest a possible association between prolonged or excessive exposure to ultrasound waves and adverse outcomes such as low birth weight, developmental delays, or hearing impairment. Additionally, obtaining informed consent from patients is crucial in mitigating liability risks. Patients should be informed about the purpose of the ultrasound examination, its benefits, limitations, potential risks (even if minimal), and any alternative diagnostic options available. This ensures that patients know the procedure and can make informed decisions about their healthcare. Proper documentation helps establish a clear record of the care provided and can serve as evidence in any legal disputes.
Collapse
Affiliation(s)
- Haiting Sun
- Department of Ultrasound, The Affiliated Xiangshan Hospital of Wenzhou Medical University, Ningbo, 315700, Zhejiang Province, PR China
| | - An Wu
- Department of Ultrasound, The Affiliated Xiangshan Hospital of Wenzhou Medical University, Ningbo, 315700, Zhejiang Province, PR China
| | - Minli Lu
- Department of Ultrasound, The Affiliated Xiangshan Hospital of Wenzhou Medical University, Ningbo, 315700, Zhejiang Province, PR China
| | - Shan Cao
- Department of Obstetrics, The Affiliated Second People's Hospital of Yuhang District, Hangzhou City, Hangzhou, 311100, Zhejiang Province, PR China
| |
Collapse
|
2
|
Moyano DB, Paraiso DA, González-Lezcano RA. Possible Effects on Health of Ultrasound Exposure, Risk Factors in the Work Environment and Occupational Safety Review. Healthcare (Basel) 2022; 10:423. [PMID: 35326901 PMCID: PMC8954895 DOI: 10.3390/healthcare10030423] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/12/2022] [Accepted: 02/22/2022] [Indexed: 02/05/2023] Open
Abstract
Ultrasonic waves are mechanical waves with a frequency greater than 20,000 Hz. Ultrasonic waves are emitted by devices that are used in industry or that have a medical or aesthetic purpose. There is growing interest in the effect of ultrasound absorption on the human body, since people's exposure to these acoustic waves has increased considerably in recent years. There are more and more devices that emit ultrasounds used for different sanitary procedures, aesthetic treatments and industrial processes, creating more possibilities of ultrasound noise, and therefore an increased risk of occupational hazard and occupational danger. Experiments on animals have shown damage to internal organs from receiving different ultrasonic frequencies. The main task of this work was to organize and summarize recent studies on ultrasound to reflect the current state of this technique and establish a systematic basis for future lines of research. This work has allowed us to better understand the unknown field of these high frequencies of sound, and highlights the need to carry out more studies on the ultrasound emissions that can be absorbed by the human body to determine how this energy could affect humans by calculating the maximum dose of exposure and developing manuals for the use of ultrasound-emitting equipment to protect the health of workers and all people. It is necessary to develop regulations by public administrations to improve the protection of workers, health professionals, patients and all people in general for better occupational safety, indoor environmental quality and environmental health.
Collapse
Affiliation(s)
- David Baeza Moyano
- Department of Chemistry and Biochemistry, Campus Montepríncipe University San Pablo CEU, Alcorcón, 28668 Madrid, Spain;
| | - Daniel Arranz Paraiso
- Department Pharmaceutical and Health Sciences, Knowledge Area Pharmaceutics and Pharmaceutical Technology, Campus Montepríncipe, University San Pablo CEU, Alcorcón, 28668 Madrid, Spain;
| | - Roberto Alonso González-Lezcano
- Architecture and Design Department, Escuela Politécnica Superior, Campus Montepríncipe, University San Pablo CEU, Alcorcón, 28668 Madrid, Spain
| |
Collapse
|
3
|
Dudwiesus H, Merz E. How safe is it to use ultrasound in prenatal medicine? Facts and contradictions - Part 2 - Laboratory experiments regarding non-thermal effects and epidemiological studies. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2021; 42:460-502. [PMID: 33836546 DOI: 10.1055/a-1394-6194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The first part of this CME article (issue 5/20) provided a detailed examination of the biophysical effects of ultrasound waves, the exposure values, and in particular the thermal effect. In vivo and in vitro measurements have shown that the temperature increase in tissue associated with B-mode ultrasound is far too low to pose a potential risk. Even experiments with exposure values in the range of pulsed Doppler have shown that temperature increases of over 1.5 °C can only occur in areas in direct contact with the probe, thus making a limited exposure time particularly in the case of transvaginal application advisable. The second part of this CME article describes various laboratory and animal experiments for evaluating non-thermal effects and also presents the most important epidemiological studies in the last 30 years in the form of an overview and review. In addition to direct insonation of isolated cells to examine possible mutagenic effects, the blood of patients exposed in vivo to ultrasound was also analyzed in multiple experiments. Reproducible chromosome aberrations could not be found in any of the studies. In contrast, many experiments on pregnant rodents showed some significant complications, such as abortion, deformities, and behavioral disorders. As in the case of thermal effects, the results of these experiments indicate the presence of an intensity- or pressure-dependent effect threshold. Numerous epidemiological studies examining possible short-term and long-term consequences after intrauterine ultrasound exposure are available with the most important studies being discussed in the following. In contrast to information presented incorrectly in the secondary literature and in the lay press, health problems could not be seen in the children observed in the postpartum period in any of these studies.
Collapse
Affiliation(s)
| | - Eberhard Merz
- Centre for Ultrasound and Prenatal Medicine Frankfurt/Main, Germany
| |
Collapse
|
4
|
Mogren I, Ntaganira J, Sengoma JPS, Holmlund S, Small R, Pham Thi L, Kidanto HL, Ngarina M, Bergström C, Edvardsson K. Maternal health care professionals' experiences and views on the use of obstetric ultrasound in Rwanda: A cross-sectional study. BMC Health Serv Res 2021; 21:789. [PMID: 34376210 PMCID: PMC8356395 DOI: 10.1186/s12913-021-06758-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 07/12/2021] [Indexed: 11/25/2022] Open
Abstract
Background This study, undertaken in Rwanda, aimed to investigate health professionals’ experiences and views on the following topics: current clinical guidelines for ultrasound from second trimester at the clinic, regional and national levels, and adherence to clinical guidelines; medically indicated ultrasound examinations; non-medical use of ultrasound including ultrasounds on maternal request; commercialisation of ultrasound; the value of ultrasound in relation to other clinical examinations in pregnancy; and ultrasound and medicalisation of pregnancy. Methods A cross-sectional design was adopted. Health professionals providing antenatal care and delivery services to pregnant women in 108 health facilities were invited to complete a survey, which was developed based on the results of earlier qualitative studies undertaken as part of the CROss Country Ultrasound Study (CROCUS). Results Nine hundred and seven health professionals participated: obstetricians/gynecologists (3.2%,) other physicians (24.5%), midwives (29.7%) and nurses (42.7%). Few physicians reported the existence of clinical guidelines at clinic, regional or national levels in Rwanda, and guidelines were moderately adhered to. Three obstetric ultrasound examinations were considered medically indicated in an uncomplicated pregnancy. Most participants (73.0%) were positive about obstetric ultrasound examinations on maternal request. Commercialisation was not considered a problem, and the majority (88.5%) agreed that ultrasound had contributed to medicalisation of pregnancy. Conclusions Findings indicate that clinical guidelines for the use of obstetric ultrasound are limited in Rwanda. Non-medically indicated obstetric ultrasound was not considered a current problem at any level of the healthcare system. The positive attitude to obstetric ultrasound examinations on maternal request may contribute to further burden on a maternal health care system with limited resources. It is essential that limited obstetric ultrasound resources are allocated where they are most beneficial, and clearly stated medical indications would likely facilitate this.
Collapse
Affiliation(s)
- Ingrid Mogren
- Department of Clinical Sciences, Obstetrics and Gynecology, Umeå University, S-90187, Umeå, Sweden. .,Judith Lumley Centre, School of Nursing and Midwifery, La Trobe University, Melbourne, Australia.
| | - Joseph Ntaganira
- School of Public Health, College of Medicine and Health Sciences, University of Rwanda, Kigali, Rwanda
| | - Jean Paul Semasaka Sengoma
- Department of Clinical Sciences, Obstetrics and Gynecology, Umeå University, S-90187, Umeå, Sweden.,School of Public Health, College of Medicine and Health Sciences, University of Rwanda, Kigali, Rwanda
| | - Sophia Holmlund
- Department of Clinical Sciences, Obstetrics and Gynecology, Umeå University, S-90187, Umeå, Sweden.,Department of Nursing, Umeå University, Umeå, Sweden
| | - Rhonda Small
- Judith Lumley Centre, School of Nursing and Midwifery, La Trobe University, Melbourne, Australia.,Department of Women's and Children's and Reproductive Health, Karolinska Institutet, Stockholm, Sweden
| | - Lan Pham Thi
- Department of Dermatology and Venereology, Hanoi Medical University, Hanoi, Vietnam
| | | | - Matilda Ngarina
- Department of Obstetrics and Gynaecology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Cecilia Bergström
- Department of Clinical Sciences, Obstetrics and Gynecology, Umeå University, S-90187, Umeå, Sweden
| | - Kristina Edvardsson
- Judith Lumley Centre, School of Nursing and Midwifery, La Trobe University, Melbourne, Australia
| |
Collapse
|
5
|
Efectos biológicos adversos y seguridad del ultrasonido en el embarazo. Revisión sistemática. PERINATOLOGÍA Y REPRODUCCIÓN HUMANA 2018. [DOI: 10.1016/j.rprh.2018.06.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
6
|
Lash TL, Collin LJ, Van Dyke ME. The replication crisis in epidemiology: snowball, snow job, or winter solstice? CURR EPIDEMIOL REP 2018; 5:175-183. [PMID: 33907664 PMCID: PMC8075285 DOI: 10.1007/s40471-018-0148-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE OF REVIEW Like a snowball rolling down a steep hill, the most recent crisis over the perceived lack of reproducibility of scientific results has outpaced the evidence of crisis. It has led to new actions and new guidelines that have been rushed to market without plans for evaluation, metrics for success, or due consideration of the potential for unintended consequences. RECENT FINDINGS The perception of the crisis is at least partly a snow job, heavily influenced by a small number of centers lavishly funded by a single foundation, with undue and unsupported attention to preregistration as a solution to the perceived crisis. At the same time, the perception of crisis provides an opportunity for introspection. Two studies' estimates of association may differ because of undue attention on null hypothesis statistical testing, because of differences in the distribution of effect modifiers, because of differential susceptibility to threats to validity, or for other reasons. Perhaps the expectation of what reproducible epidemiology ought to look like is more misguided than the practice of epidemiology. We advocate for the idea of "replication and advancement." Studies should not only replicate earlier work, but also improve on it in by enhancing the design or analysis. SUMMARY Abandoning blind reliance on null hypothesis significance testing for statistical inference, finding consensus on when pre-registration of non-randomized study protocols has merit, and focusing on replication and advance are the most certain ways to emerge from this solstice for the better.
Collapse
Affiliation(s)
- Timothy L. Lash
- Department of Epidemiology, Rollins School of Public Health, Emory University
| | - Lindsay J. Collin
- Department of Epidemiology, Rollins School of Public Health, Emory University
| | - Miriam E. Van Dyke
- Department of Epidemiology, Rollins School of Public Health, Emory University
| |
Collapse
|
7
|
Rosman NP, Vassar R, Doros G, DeRosa J, Froman A, DiMauro A, Santiago S, Abbott J. Association of Prenatal Ultrasonography and Autism Spectrum Disorder. JAMA Pediatr 2018; 172:336-344. [PMID: 29435580 PMCID: PMC5875374 DOI: 10.1001/jamapediatrics.2017.5634] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Accepted: 12/07/2017] [Indexed: 12/28/2022]
Abstract
Importance The prevalence of autism spectrum disorder (ASD) has been increasing rapidly, with current estimates of 1 in 68 children affected. Simultaneously, use of prenatal ultrasonography has increased substantially, with limited investigation into its safety and effects on brain development. Animal studies have demonstrated that prenatal ultrasonography can adversely affect neuronal migration. Objective To quantify prenatal ultrasound exposure by the frequency, timing, duration, and strength of ultrasonographic scans in children with later ASD, developmental delay, and typical development. Design, Setting, and Participants This case-control study included 107 patients with ASD, 104 control individuals with developmental delay, and 209 controls with typical development. Participants were identified from medical records based on prenatal care and delivery at Boston Medical Center, a diverse, academic, safety-net medical center, from July 1, 2006, through December 31, 2014, with a gestational age at birth of at least 37 weeks. Data were analyzed from May 1, 2015, through November 30, 2017. Exposures Ultrasonographic exposure was quantified by the number and timing of scans, duration of exposure, mean strength (depth, frame rate, mechanical index, and thermal index), and time of Doppler and 3- and 4-dimensional imaging. Main Outcomes and Measures Among participants with ASD and controls with developmental delay and typical development, ultrasound exposure was quantified and compared per trimester and for the entire pregnancy, with adjustment for infant sex, gestational age at birth, and maternal age. Results A total of 420 participants were included in the study (328 boys [78.1%] and 92 girls [21.9%]; mean age as of January 1, 2016, 6.6 years; 95% CI, 6.5-6.8 years). The ASD group received a mean of 5.9 scans (95% CI, 5.2-6.6), which was not significantly different from the 6.1 scans (95% CI, 5.4-6.8) in the developmental delay group or the 6.3 scans (95% CI, 5.8-6.8) in the typical development group. Compared with the typical development group, the ASD group had shorter duration of ultrasound exposure during the first (290.4 seconds [95% CI, 212.8-368.0 seconds] vs 406.4 seconds [95% CI, 349.5-463.3 seconds]) and second (1687.6 seconds [95% CI, 1493.8-1881.4 seconds] vs 2011.0 seconds [95% CI, 1868.9-2153.1 seconds]) trimesters but no difference in the number of scans. The ASD group had greater mean depth of ultrasonographic penetration than the developmental delay group in the first trimester (12.5 cm [95% CI, 12.0-13.0 cm] vs 11.6 cm [95% CI, 11.1-12.1 cm]). The ASD group had greater mean depth than the typical development group during the first (12.5 cm [95% CI, 12.0-13.0 cm] vs 11.6 cm [95% CI, 11.3-12.0 cm]) and the second (12.9 cm [95% CI, 12.6-13.3 cm] vs 12.5 cm [95% CI, 12.2-12.7 cm]) trimesters. Conclusions and Relevance This study found significantly greater mean depth of ultrasonographic penetration in the ASD group compared with the developmental delay group in the first trimester and compared with the typical development group in the first and second trimesters. Further research is needed to determine whether other variables of ultrasound exposure also have adverse effects on the developing fetus.
Collapse
Affiliation(s)
- N. Paul Rosman
- Department of Pediatrics, Boston University School of Medicine, Boston Medical Center, Boston, Massachusetts
- Department of Neurology, Boston University School of Medicine, Boston Medical Center, Boston, Massachusetts
- Division of Pediatric Neurology, Boston University School of Medicine, Boston Medical Center, Boston, Massachusetts
- Departments of Pediatrics and Neurology, Division of Pediatric Neurology, Boston Medical Center, Boston, Massachusetts
| | - Rachel Vassar
- medical student at Boston University School of Medicine, Boston, Massachusetts
- Department of Pediatrics, Benioff Children’s Hospital, University of California, San Francisco
| | - Gheorghe Doros
- Department of Biostatistics, Boston University School of Public Health, Boston, Massachusetts
| | - James DeRosa
- graduate student at Boston University School of Public Health, Boston, Massachusetts
| | - Allison Froman
- graduate student at Boston University School of Public Health, Boston, Massachusetts
| | - Audrey DiMauro
- medical student at Boston University School of Medicine, Boston, Massachusetts
- Department of Pediatrics, Floating Hospital for Children, Tufts Medical Center, Boston, Massachusetts
| | - Sherry Santiago
- Division of Pediatric Neurology, Boston University School of Medicine, Boston Medical Center, Boston, Massachusetts
- Division of Pediatric Neurology, Puerto Rico Children’s Hospital, Bayamón, Puerto Rico
| | - Jodi Abbott
- Division of Maternal and Fetal Medicine, Department of Obstetrics and Gynecology, Boston University School of Medicine, Boston, Massachusetts
| |
Collapse
|
8
|
Quality and Safety of Obstetric Practices Using New Modalities— Ultrasound, MR, and CT. Clin Obstet Gynecol 2017; 60:546-561. [DOI: 10.1097/grf.0000000000000300] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
9
|
Retz K, Kotopoulis S, Kiserud T, Matre K, Eide GE, Sande R. Measured acoustic intensities for clinical diagnostic ultrasound transducers and correlation with thermal index. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 50:236-241. [PMID: 27608142 DOI: 10.1002/uog.17298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Revised: 08/14/2016] [Accepted: 08/26/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES To investigate if the thermal index for bone (TIB) displayed on screen is an adequate predictor for the derated spatial-peak temporal-average (ISPTA.3 ) and spatial-peak pulse-average (ISPPA.3 ) acoustic intensities in a selection of clinical diagnostic ultrasound machines and transducers. METHODS We calibrated five clinical diagnostic ultrasound scanners and 10 transducers, using two-dimensional grayscale, color Doppler and pulsed-wave Doppler, both close to and far from the transducer, with a TIB between 0.1 and 4.0, recording 103 unique measurements. Acoustic measurements were performed in a bespoke three-axis computer-controlled scanning tank, using a 200-μm-diameter calibrated needle hydrophone. RESULTS There was significant but poor correlation between the acoustic intensities and the on-screen TIB. At a TIB of 0.1, the ISPTA.3 range was 0.51-50.49 mW/cm2 and the ISPPA.3 range was 0.01-207.29 W/cm2 . At a TIB of 1.1, the ISPTA.3 range was 19.02-309.44 mW/cm2 and the ISPPA.3 range was 3.87-51.89 W/cm2 . CONCLUSIONS TIB is a poor predictor for ISPTA.3 and ISPPA.3 and for the potential bioeffects of clinical diagnostic ultrasound scanners. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- K Retz
- Department of Obstetrics and Gynecology, Helse Stavanger, Stavanger, Norway
| | - S Kotopoulis
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - T Kiserud
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Science, University of Bergen, Bergen, Norway
| | - K Matre
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway
| | - G E Eide
- Centre for Clinical Research, Haukeland University Hospital, Bergen, Norway
- Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - R Sande
- Department of Obstetrics and Gynecology, Helse Stavanger, Stavanger, Norway
- Department of Clinical Science, University of Bergen, Bergen, Norway
| |
Collapse
|
10
|
Höglund Carlsson L, Saltvedt S, Anderlid BM, Westerlund J, Gillberg C, Westgren M, Fernell E. Prenatal ultrasound and childhood autism: long-term follow-up after a randomized controlled trial of first- vs second-trimester ultrasound. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2016; 48:285-288. [PMID: 27184020 DOI: 10.1002/uog.15962] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 05/10/2016] [Accepted: 05/11/2016] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To analyze whether the frequency of autism spectrum disorder (ASD) in a cohort of Swedish children differs between those exposed to ultrasound in the 12(th) week and those exposed to ultrasound in the 18(th) week of gestation. METHODS The study cohort consisted of approximately 30 000 children born between 1999 and 2003 to mothers who had been randomized to a prenatal ultrasound examination at either 12 or 18 weeks' gestation as part of the framework for a study on nuchal translucency screening. The outcome measure in the present study was the rate of ASD diagnoses among the children. Information on ASD diagnoses was based on data from the Swedish social insurance agency concerning childcare allowance granted for ASD. RESULTS Between 1999 and 2003, a total of 14 726 children were born to women who underwent a 12-week ultrasound examination and 14 596 to women who underwent an 18-week ultrasound examination. Of these, 181 (1.2%) and 176 (1.2%) children, respectively, had been diagnosed with ASD. There was no difference in ASD frequency between the early and late ultrasound groups. CONCLUSIONS Women subjected to at least one prenatal ultrasound examination at either 12 or 18 weeks' gestation had children with similar rates of ASD. However, this result reflects routine care 10-15 years ago in Sweden. Today, higher intensity ultrasound scans are performed more frequently, at earlier stages during pregnancy and for non-medical purposes, implying longer exposure time for the fetus. This change in the use of ultrasound necessitates further follow-up study of the possible effects that high exposure to ultrasound during the gestational period has on the developing brain. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- L Höglund Carlsson
- Gillberg Neuropsychiatry Centre, Gothenburg University, Gothenburg, Sweden
- Department of Pediatrics, Karolinska University Hospital, Stockholm, Sweden
| | - S Saltvedt
- Department of Obstetrics and Gynaecology, Karolinska University Hospital, Stockholm, Sweden
| | - B-M Anderlid
- Department of Molecular Medicine and Surgery and Centre for Molecular Medicine, Karolinska Institutet and Department of Clinical Genetics, Karolinska University Hospital, Stockholm, Sweden
| | - J Westerlund
- Gillberg Neuropsychiatry Centre, Gothenburg University, Gothenburg, Sweden
- Department of Psychology, Stockholm University, Stockholm, Sweden
| | - C Gillberg
- Gillberg Neuropsychiatry Centre, Gothenburg University, Gothenburg, Sweden
| | - M Westgren
- Center for Fetal Medicine, Karolinska University Hospital and Division of Clintec, Karolinska Institutet, Stockholm, Sweden
| | - E Fernell
- Gillberg Neuropsychiatry Centre, Gothenburg University, Gothenburg, Sweden
| |
Collapse
|
11
|
Ultrasound-targeted microbubble destruction in gene therapy: A new tool to cure human diseases. Genes Dis 2016; 4:64-74. [PMID: 30258909 PMCID: PMC6136600 DOI: 10.1016/j.gendis.2016.08.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 08/01/2016] [Indexed: 01/11/2023] Open
Abstract
Human gene therapy has made significant advances in less than two decades. Within this short period of time, gene therapy has proceeded from the conceptual stage to technology development and laboratory research, and finally to clinical trials for the treatment of a variety of deadly diseases. Cardiovascular disease, cancer, and stroke are leading causes of death worldwide. Despite advances in medical, interventional, radiation and surgical treatments, the mortality rate remains high, and the need for novel therapies is great. Gene therapy provides an efficient approach to disease treatment. Notable advances in gene therapy have been made for genetic disorders, including severe combined immune deficiency, chronic granulomatus disorder, hemophilia and blindness, as well as for acquired diseases, including cancer and neurodegenerative and cardiovascular diseases. However, lack of an efficient delivery system to target cells as well as the difficulty of sustained expression of transgenes has hindered advancements in gene therapy. Ultrasound targeted microbubble destruction (UTMD) is a promising approach for target-specific gene delivery, and it has been successfully investigated for the treatment of many diseases in the past decade. In this paper, we review UTMD-mediated gene delivery for the treatment of cardiovascular diseases, cancer and stroke.
Collapse
|
12
|
Salvesen K. Author's Reply re: Maternal outcomes at 3 months after planned caesarean section versus planned vaginal birth for twin pregnancies in the Twin Birth Study: a randomised controlled trial. BJOG 2016; 123:644-5. [PMID: 26914899 DOI: 10.1111/1471-0528.13770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2015] [Indexed: 11/30/2022]
Affiliation(s)
- Kå Salvesen
- Professor at Norwegian University for Science and Technology, Trondheim, Norway
| |
Collapse
|
13
|
van der Pol CB, McInnes MDF, Petrcich W, Tunis AS, Hanna R. Is quality and completeness of reporting of systematic reviews and meta-analyses published in high impact radiology journals associated with citation rates? PLoS One 2015; 10:e0119892. [PMID: 25775455 PMCID: PMC4361663 DOI: 10.1371/journal.pone.0119892] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Accepted: 01/20/2015] [Indexed: 01/01/2023] Open
Abstract
Purpose The purpose of this study is to determine whether study quality and completeness of reporting of systematic reviews (SR) and meta-analyses (MA) published in high impact factor (IF) radiology journals is associated with citation rates. Methods All SR and MA published in English between Jan 2007–Dec 2011, in radiology journals with an IF >2.75, were identified on Ovid MEDLINE. The Assessing the Methodologic Quality of Systematic Reviews (AMSTAR) checklist for study quality, and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist for study completeness, was applied to each SR & MA. Each SR & MA was then searched in Google Scholar to yield a citation rate. Spearman correlation coefficients were used to assess the relationship between AMSTAR and PRISMA results with citation rate. Multivariate analyses were performed to account for the effect of journal IF and journal 5-year IF on correlation with citation rate. Values were reported as medians with interquartile range (IQR) provided. Results 129 studies from 11 journals were included (50 SR and 79 MA). Median AMSTAR result was 8.0/11 (IQR: 5–9) and median PRISMA result was 23.0/27 (IQR: 21–25). The median citation rate for SR & MA was 0.73 citations/month post-publication (IQR: 0.40–1.17). There was a positive correlation between both AMSTAR and PRISMA results and SR & MA citation rate; ρ=0.323 (P=0.0002) and ρ=0.327 (P=0.0002) respectively. Positive correlation persisted for AMSTAR and PRISMA results after journal IF was partialed out; ρ=0.243 (P=0.006) and ρ=0.256 (P=0.004), and after journal 5-year IF was partialed out; ρ=0.235 (P=0.008) and ρ=0.243 (P=0.006) respectively. Conclusion There is a positive correlation between the quality and the completeness of a reported SR or MA with citation rate which persists when adjusted for journal IF and journal 5-year IF.
Collapse
Affiliation(s)
| | - Matthew D. F. McInnes
- Department of Radiology, University of Ottawa, Ottawa, Ontario, Canada
- Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
- * E-mail:
| | - William Petrcich
- Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
| | - Adam S. Tunis
- Department of Radiology, University of Ottawa, Ottawa, Ontario, Canada
| | - Ramez Hanna
- Department of Radiology, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
14
|
Edvardsson K, Small R, Persson M, Lalos A, Mogren I. 'Ultrasound is an invaluable third eye, but it can't see everything': a qualitative study with obstetricians in Australia. BMC Pregnancy Childbirth 2014; 14:363. [PMID: 25336335 PMCID: PMC4287579 DOI: 10.1186/1471-2393-14-363] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2014] [Accepted: 10/07/2014] [Indexed: 11/28/2022] Open
Abstract
Background Obstetric ultrasound has come to play a significant role in obstetrics since its introduction in clinical care. Today, most pregnant women in the developed world are exposed to obstetric ultrasound examinations, and there is no doubt that the advantages of obstetric ultrasound technique have led to improvements in pregnancy outcomes. However, at the same time, the increasing use has also raised many ethical challenges. This study aimed to explore obstetricians’ experiences of the significance of obstetric ultrasound for clinical management of complicated pregnancy and their perceptions of expectant parents’ experiences. Methods A qualitative study was undertaken in November 2012 as part of the CROss-Country Ultrasound Study (CROCUS). Semi-structured individual interviews were held with 14 obstetricians working at two large hospitals in Victoria, Australia. Transcribed data underwent qualitative content analysis. Results An overall theme emerged during the analyses, ‘Obstetric ultrasound - a third eye’, reflecting the significance and meaning of ultrasound in pregnancy, and the importance of the additional information that ultrasound offers clinicians managing the surveillance of a pregnant woman and her fetus. This theme was built on four categories: I:‘Everyday-tool’ for pregnancy surveillance, II: Significance for managing complicated pregnancy, III: Differing perspectives on obstetric ultrasound, and IV: Counselling as a balancing act. In summary, the obstetricians viewed obstetric ultrasound as an invaluable tool in their everyday practice. More importantly however, the findings emphasise some of the clinical dilemmas that occur due to its use: the obstetricians’ and expectant parents’ differing perspectives and expectations of obstetric ultrasound examinations, the challenges of uncertain ultrasound findings, and how this information was conveyed and balanced by obstetricians in counselling expectant parents. Conclusions This study highlights a range of previously rarely acknowledged clinical dilemmas that obstetricians face in relation to the use of obstetric ultrasound. Despite being a tool of considerable significance in the surveillance of pregnancy, there are limitations and uncertainties that arise with its use that make counselling expectant parents challenging. Research is needed which further investigates the effects and experiences of the continuing worldwide rapid technical advances in surveillance of pregnancies.
Collapse
Affiliation(s)
- Kristina Edvardsson
- Department of Clinical Sciences, Obstetrics and Gynecology, Umeå University, SE 901 87 Umeå, Sweden.
| | | | | | | | | |
Collapse
|
15
|
Forward H, Yazar S, Hewitt AW, Khan J, Mountain JA, Pesudovs K, McKnight CM, Tan AX, Pennell CE, Mackey DA, Newnham JP. Multiple prenatal ultrasound scans and ocular development: 20-year follow-up of a randomized controlled trial. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2014; 44:166-170. [PMID: 24789332 DOI: 10.1002/uog.13399] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2013] [Revised: 04/14/2014] [Accepted: 04/20/2014] [Indexed: 06/03/2023]
Abstract
OBJECTIVES Through comprehensive ophthalmic examination of adult offspring we sought to determine the impact of multiple prenatal ultrasound scans on ocular development. METHODS 2743 pregnant women recruited to the Western Australian Pregnancy (Raine) Cohort study during 1989-1991 were randomized to receive at King Edward Memorial Hospital, Western Australia either multiple prenatal ultrasound scans and Doppler flow studies (intensive group) or a single ultrasound scan at 18 weeks' gestation. Neonatal birth weight of the offspring and other physical measurements were collected prospectively. At age 20 years, participants underwent a comprehensive ophthalmic examination including measurement of ocular biometry and visual acuity. RESULTS Complete data were available for 1134 adult offspring participants. The mothers of 563 of these had been randomized to receive multiple prenatal ultrasound scans. The mean age of participants at follow-up was 20.0 years. There was no statistically significant difference between the two groups with regard to ocular biometric or visual outcomes, except for slightly higher intraocular pressure identified in individuals exposed to multiple ultrasound scans (P = 0.034). Although infants in the intensive-ultrasound arm were more likely to have birth weights in the lower quartiles, this was not reflected in adult eye development. Axial length, lens thickness, corneal curvature and thickness and optic cup to disc ratio (a risk factor for glaucomatous optic neuropathy) were not significantly influenced by the more frequent ultrasound protocol. CONCLUSIONS Prior to this study, there was a paucity of safety data for ultrasound with regard to eye development. We found that frequent in-utero exposure to ultrasound, including B-mode imaging and the use of spectral Doppler mode from 18 weeks' gestation, had no significant impact on visual outcomes or ocular biometry.
Collapse
Affiliation(s)
- H Forward
- Centre for Ophthalmology and Vision Science, University of Western Australia, Perth, Australia; Lions Eye Institute, Perth, Australia
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Fazio RL, Lykins AD, Cantor JM. Elevated rates of atypical handedness in paedophilia: theory and implications. Laterality 2014; 19:690-704. [PMID: 24666135 PMCID: PMC4151814 DOI: 10.1080/1357650x.2014.898648] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Revised: 01/16/2014] [Accepted: 02/23/2014] [Indexed: 11/18/2022]
Abstract
Multiple factors determine handedness including genetics, prenatal stress and post-natal environmental conditions. Atypical handedness, whether manifest as increased sinistrality or decreased strength of lateral preference, has been noted in a wide variety of populations with neuropathology. Those with atypical sexual preferences, specifically paedophilia, also manifest reduced rates of right-handedness. This paper uses the largest sample of phallometrically assessed men to date to establish the pattern of atypical handedness in paedophilia. Specifically, whereas prior research has largely characterized participants dichotomously as right-handed or non-right-handed and/or used self-report of writing hand, this paper expands upon such reports by using the Edinburgh Handedness Inventory's laterality quotient. Participants' handedness and phallometrically assessed sexual preference were analyzed both as continuous and categorical variables, and the responses of those scoring in the range of ambiguous-handedness were evaluated to ascertain whether they were ambiguously handed or more accurately described as mixed-handed. Results indicated those producing scores in the range of ambiguous-handedness demonstrated response patterns consistent with ambiguous-handedness, rather than mixed-handedness. Paedophiles demonstrated high rates of non-right-handedness primarily manifested as sinistrality, whereas those who had a sexual preference for pubescent children evidenced increased ambiguous-handedness. Results support a view of ambiguous-handedness as less pathological than previously hypothesized, and of a neurodevelopmental origin of paraphilic sexual preferences.
Collapse
Affiliation(s)
- Rachel L. Fazio
- Law and Mental Health Program, Centre for Addiction and Mental Health (CAMH), Toronto, ON, Canada
| | - Amy D. Lykins
- School of Behavioural, Cognitive and Social Sciences, University of New England, Armidale, NSW, Australia
| | - James M. Cantor
- Law and Mental Health Program, Centre for Addiction and Mental Health (CAMH), Toronto, ON, Canada
- Department of Psychiatry, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
17
|
Tunis AS, McInnes MDF, Hanna R, Esmail K. Association of Study Quality with Completeness of Reporting: Have Completeness of Reporting and Quality of Systematic Reviews and Meta-Analyses in Major Radiology Journals Changed Since Publication of the PRISMA Statement? Radiology 2013; 269:413-26. [DOI: 10.1148/radiol.13130273] [Citation(s) in RCA: 122] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
18
|
Abstract
Ultrasound is, arguably, the most commonly used diagnostic procedure in obstetrics. It is convenient, painless, yields immediate, extensive results, and is widely considered to be safe. Some (but not all) benefits described in the literature have been validated by evidence-based analysis, such as pregnancy dating. Others are considered clinically useful, although objective evidence may be less strong. As is the case with almost any medical procedure, however, its performance carries some risks: misdiagnosis on the one hand and possible undesired effects on the other. The general belief exists that diagnostic ultrasound (DUS) does not pose any risk to the pregnant patient nor to her fetus. Nonetheless, ultrasound is a form of energy and, as such, demonstrates effects in biological tissues it traverses (bioeffects). The physical mechanisms responsible for these effects are thermal or non-thermal (mechanical). It is the role of science to show whether any of these bioeffects may be harmful. A risk-benefit analysis may also be important, as well as education of the end users to assure patients' safety.
Collapse
Affiliation(s)
- Jacques S Abramowicz
- Department of Ob/Gyn, Division of Maternal Fetal Medicine and Center for Fetal diagnosis and Therapy, Wayne State university, Detroit, MI.
| |
Collapse
|
19
|
Sande RK, Matre K, Eide GE, Kiserud T. The effects of reducing the thermal index for bone from 1.0 to 0.5 and 0.1 on common obstetric pulsed wave Doppler measurements in the second half of pregnancy. Acta Obstet Gynecol Scand 2013; 92:790-6. [DOI: 10.1111/aogs.12114] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2012] [Accepted: 02/05/2013] [Indexed: 11/30/2022]
Affiliation(s)
| | - Knut Matre
- Institute of Medicine; University of Bergen; Bergen; Norway
| | | | | |
Collapse
|
20
|
Sande RK, Matre K, Eide GE, Kiserud T. The effect of ultrasound output level on obstetric biometric measurements. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:37-43. [PMID: 23078999 DOI: 10.1016/j.ultrasmedbio.2012.08.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Revised: 07/18/2012] [Accepted: 08/15/2012] [Indexed: 06/01/2023]
Abstract
We tested the effect of reducing the ultrasound output energy on obstetric measurements made from two-dimensional (2-D) grayscale images. We measured three fetal structures (femur, umbilical vein and lateral cerebral ventricle) in 113 pregnant women, commencing with an output energy that provided a thermal index for bone (TIB) of ≤1.0, and then repeated the measurements at TIB ≤ 0.5 and then TIB ≤ 0.1. There was a trend toward shorter femur measurements and larger umbilical vein diameter measurements with decreasing output energy. However, since these effects (which did not exceed 0.03 mm) were very small compared with the inter- and intraobserver variations, they were considered to be of no clinical significance. Furthermore, the residuals did not increase when the output energy decreased, indicating that the precision of the measurements was unaltered. We conclude that using a reduced output energy setting corresponding to a TIB of 0.1 does not compromise ultrasound biometry findings.
Collapse
Affiliation(s)
- Ragnar Kvie Sande
- Clinical Fetal Physiology Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway.
| | | | | | | |
Collapse
|
21
|
Abramowicz JS. Ultrasound and autism: association, link, or coincidence? JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:1261-1269. [PMID: 22837291 DOI: 10.7863/jum.2012.31.8.1261] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Autism spectrum disorders (ASDs) affect an estimated 1% of children in the United States. The etiology is probably multifactorial, including genetic components and exposure to infections, toxins, and other environmental factors, particularly unfavorable perinatal and neonatal conditions. There has been an increase in the frequency of diagnosis of ASDs over the last 20 years with a parallel increase in the use of obstetric diagnostic ultrasound, with prenatal ultrasound exposure mentioned as the possible main etiology for autism "epidemics." Central nervous system alterations have been described in ASDs, and certain similar changes have been described in animals after exposure to ultrasound. However, analysis of in utero exposure in humans has failed to show harmful effects in neonates or children, particularly in school performance, attention disorders, and behavioral changes. There is no independently confirmed peer-reviewed published evidence that a cause-effect relationship exists between in utero exposure to clinical ultrasound and development of ASDs in childhood. Ultrasound is a form of energy with effects in the tissues it traverses, and its use should be restricted to medical indications, by trained professionals, for as short a period and as low an intensity as compatible with accurate diagnosis.
Collapse
Affiliation(s)
- Jacques S Abramowicz
- Department of Obstetrics and Gynecology and Rush Fetal and Neonatal Medicine Center, Rush University, Chicago, Illinois 60612, USA.
| |
Collapse
|
22
|
Huang K, Tao F, Raven J, Liu L, Wu X, Tang S. Utilization of antenatal ultrasound scan and implications for caesarean section: a cross-sectional study in rural Eastern China. BMC Health Serv Res 2012; 12:93. [PMID: 22494358 PMCID: PMC3350450 DOI: 10.1186/1472-6963-12-93] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Accepted: 04/12/2012] [Indexed: 11/30/2022] Open
Abstract
Background Antenatal ultrasound scan is a widely accepted component of antenatal care. Studies have looked at the relationship between ultrasound scanning and caesarean section (CS) in certain groups of women in China. However, there are limited data on the utilization of antenatal ultrasound scanning in the general population, including its association with CS. The purpose of this study is to describe the utilization of antenatal ultrasound screening in rural Eastern China and to explore the association between antenatal ultrasound scan and uptake of CS. Methods Based on a cluster randomized sample, a total of 2326 women with childbirth participated in the study. A household survey was conducted to collect socio-economic information, obstetric history and utilization of maternal health services. Results Coverage of antenatal care was 96.8% (2251/2326). During antenatal care, 96.1% (2164/2251) women received ultrasound screening and the reported average number was 2.55. 46.8% women received at least 3 ultrasound scans and the maximum number reached 11. The CS rate was found to be 54.8% (1275/2326). After adjusting for socio-demographic and clinical variables, it showed a statistically significant association between antenatal ultrasound scans and uptake of CS by multivariate logistic regression model. High husband education level, high maternal age, having previous adverse pregnant outcome and pregnancy complications during the index pregnancy were also found to be risk factors of choosing a CS. Conclusions A high use of antenatal ultrasound scan in rural Eastern China is found and is influenced by socio-demographic and clinical factors. Evidence-based guidelines for antenatal ultrasound scans need to be developed and disseminated to clinicians including physicians, nurses and sonographers. Guidance about the appropriate use of ultrasound scans should also be shared with women in order to discourage unreasonable expectations and demands. It is important to monitor the use of antenatal ultrasound scan as well as the indications for caesarean section in rural China.
Collapse
Affiliation(s)
- Kun Huang
- School of Public Health, Anhui Medical University, Hefei city, Anhui Province, People's Republic of China
| | | | | | | | | | | |
Collapse
|
23
|
Sande RK, Matre K, Eide GE, Kiserud T. Ultrasound safety in early pregnancy: reduced energy setting does not compromise obstetric Doppler measurements. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2012; 39:438-443. [PMID: 22102527 DOI: 10.1002/uog.10148] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 11/04/2011] [Indexed: 05/31/2023]
Abstract
OBJECTIVES We hypothesized that first-trimester Doppler ultrasonography can be carried out at lower output energies than the currently advocated limits without compromising clinically important information. METHODS We recruited 42 pregnant women for an ultrasound examination at 12 weeks' gestation. Twenty-one women were examined with a transvaginal transducer, the rest with a transabdominal transducer. We used pulsed Doppler to measure pulsatility index (PI) and peak systolic velocity (PSV) in five clinically relevant fetal and maternal blood vessels. The energy indicator thermal index for bone (TIb) was set at 1.0, 0.5 and 0.1. Each measurement was repeated three times. A mixed linear regression model accounting for correlation between measurements was used to assess the effect of different TIb levels and transducers. RESULTS We were able to visualize the vessels by color Doppler and measure PI and PSV in all vessels at all energy levels in all the participants with the exception of the ductus venosus in two participants, yielding 1872 recordings for statistical analysis. A reduction in TIb from 1.0 to 0.5 and 0.1 had no effect on the PI or PSV values, nor was there any trend towards higher parameter variance with decreasing TIb. There was no difference between measured values of PI and PSV between the transducers, but the transabdominal technique was associated with a greater parameter variance. CONCLUSION Reliable first-trimester Doppler data can be obtained with output energy reduced to a TIb of 0.5 or 0.1.
Collapse
Affiliation(s)
- R K Sande
- Clinical Fetal Physiology Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway.
| | | | | | | |
Collapse
|
24
|
Aiken CE, Lees CC. Long-term effects of in utero Doppler ultrasound scanning--a developmental programming perspective. Med Hypotheses 2012; 78:539-41. [PMID: 22325988 DOI: 10.1016/j.mehy.2012.01.030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2011] [Accepted: 01/16/2012] [Indexed: 11/19/2022]
Abstract
Ultrasound scanning has been used as a diagnostic and screening tool in obstetric practice for over 50 years. There is no evidence of immediate or long-term harm to the developing fetus from exposure to B mode ultrasound. However, exposure to high levels of Doppler ultrasound during early development is increasingly common, and the full safety implications of this exposure are not clear. Doppler ultrasound exposure in utero gives rise to increased apoptosis in animal models, and there is evidence of the effects of exposure to Doppler ultrasound persisting throughout life, with increased non-right-handedness observed in human epidemiological studies. We consider the idea that there may be long-term developmental implications for fetuses exposed to Doppler ultrasound early in gestation. These effects may be mediated via thermal or mechanical disruption to the developing conceptus, giving rise to free radical damage. Excess free radical exposure early in gestation is a strong candidate for the final common pathway underlying developmental programming effects, and gives rise to concern that fetuses exposed to high levels of ultrasound are at risk of a developmental programming effect. It is suggested that there is a need for animal studies of developmental programming using exposure to Doppler ultrasound scanning as the exposure of interest, and for more observational data to be collected in the clinical setting. While these data are collected, it seems prudent to continue to adhere to the principle of 'as low as reasonably achievable' (ALARA) when exposing first-trimester fetuses to Doppler ultrasound.
Collapse
Affiliation(s)
- C E Aiken
- Division of Fetal Medicine, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge CB2 0QQ, UK
| | | |
Collapse
|
25
|
Salvesen KÅ, Lees C, Abramowicz J, Brezinka C, Ter Haar G, Maršál K. Safe use of Doppler ultrasound during the 11 to 13 + 6-week scan: is it possible? ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 37:625-628. [PMID: 21618312 DOI: 10.1002/uog.9025] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
MESH Headings
- Animals
- Female
- Fetal Development
- Humans
- Liver/embryology
- Liver/pathology
- Pregnancy
- Pregnancy Trimester, First
- Rats
- Risk Assessment
- Time Factors
- Ultrasonography, Doppler, Color/adverse effects
- Ultrasonography, Doppler, Color/instrumentation
- Ultrasonography, Doppler, Color/methods
- Ultrasonography, Prenatal/adverse effects
- Ultrasonography, Prenatal/instrumentation
- Ultrasonography, Prenatal/methods
Collapse
Affiliation(s)
- K Å Salvesen
- National Center for Fetal Medicine, St. Olav University Hospital of Trondheim and Department of Laboratory Medicine, Women's and Child Health, Norwegian University of Science and Technology, N 7006 Trondheim, Norway.
| | | | | | | | | | | |
Collapse
|