1
|
Sarvazyan N. Building Valveless Impedance Pumps From Biological Components: Progress and Challenges. Front Physiol 2022; 12:770906. [PMID: 35173623 PMCID: PMC8842681 DOI: 10.3389/fphys.2021.770906] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 12/08/2021] [Indexed: 01/20/2023] Open
Abstract
Valveless pumping based on Liebau mechanism entails asymmetrical positioning of the compression site relative to the attachment sites of the pump's elastic segment to the rest of the circuit. Liebau pumping is believed to play a key role during heart development and be involved in several other physiological processes. Until now studies of Liebau pump have been limited to numerical analyses, in silico modeling, experiments using non-biological elements, and a few indirect in vivo measurements. This review aims to stimulate experimental efforts to build Liebau pumps using biologically compatible materials in order to encourage further exploration of the fundamental mechanisms behind valveless pumping and its role in organ physiology. The covered topics include the biological occurrence of Liebau pumps, the main differences between them and the peristaltic flow, and the potential uses and body sites that can benefit from implantable valveless pumps based on Liebau principle. We then provide an overview of currently available tools to build such pumps and touch upon limitations imposed by the use of biological components. We also talk about the many variables that can impact Liebau pump performance, including the concept of resonant frequencies, the shape of the flowrate-frequency relationship, the flow velocity profiles, and the Womersley numbers. Lastly, the choices of materials to build valveless impedance pumps and possible modifications to increase their flow output are briefly discussed.
Collapse
Affiliation(s)
- Narine Sarvazyan
- Department of Pharmacology and Physiology, School of Medicine and Health Science, The George Washington University, Washington, DC, United States
| |
Collapse
|
2
|
Nagaraja S, Leichsenring K, Ambati M, De Lorenzis L, Böl M. On a phase-field approach to model fracture of small intestine walls. Acta Biomater 2021; 130:317-331. [PMID: 34119714 DOI: 10.1016/j.actbio.2021.06.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 12/15/2022]
Abstract
We address anisotropic elasticity and fracture in small intestine walls (SIWs) with both experimental and computational methods. Uniaxial tension experiments are performed on porcine SIW samples with varying alignments and quantify their nonlinear elastic anisotropic behavior. Fracture experiments on notched SIW strips reveal a high sensitivity of the crack propagation direction and the failure stress on the tissue orientation. From a modeling point of view, the observed anisotropic elastic response is studied with a continuum mechanical model stemming from a strain energy density with a neo-Hookean component and an anisotropic component with four families of fibers. Fracture is addressed with the phase-field approach, featuring two-fold anisotropy in the fracture toughness. Elastic and fracture model parameters are calibrated based on the experimental data, using the maximum and minimum limits of the experimental stress-stretch data set. A very good agreement between experimental data and computational results is obtained, the role of anisotropy being effectively captured by the proposed model in both the elastic and the fracture behavior. STATEMENT OF SIGNIFICANCE: This article reports a comprehensive experimental data set on the mechanical failure behavior of small intestinal tissue, and presents the corresponding protocols for preparing and testing the samples. On the one hand, the results of this study contribute to the understanding of small intestine mechanics and thus to understanding of load transfer mechanisms inside the tissue. On the other hand, these results are used as input for a phase-field modelling approach, presented in this article. The presented model can reproduce the mechanical failure behavior of the small intestine in an excellent way and is thus a promising tool for the future mechanical description of diseased small intestinal tissue.
Collapse
|
3
|
Piterina AV, Cloonan AJ, Meaney CL, Davis LM, Callanan A, Walsh MT, McGloughlin TM. ECM-based materials in cardiovascular applications: Inherent healing potential and augmentation of native regenerative processes. Int J Mol Sci 2009; 10:4375-4417. [PMID: 20057951 PMCID: PMC2790114 DOI: 10.3390/ijms10104375] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2009] [Revised: 09/07/2009] [Accepted: 09/30/2009] [Indexed: 01/21/2023] Open
Abstract
The in vivo healing process of vascular grafts involves the interaction of many contributing factors. The ability of vascular grafts to provide an environment which allows successful accomplishment of this process is extremely difficult. Poor endothelisation, inflammation, infection, occlusion, thrombosis, hyperplasia and pseudoaneurysms are common issues with synthetic grafts in vivo. Advanced materials composed of decellularised extracellular matrices (ECM) have been shown to promote the healing process via modulation of the host immune response, resistance to bacterial infections, allowing re-innervation and reestablishing homeostasis in the healing region. The physiological balance within the newly developed vascular tissue is maintained via the recreation of correct biorheology and mechanotransduction factors including host immune response, infection control, homing and the attraction of progenitor cells and infiltration by host tissue. Here, we review the progress in this tissue engineering approach, the enhancement potential of ECM materials and future prospects to reach the clinical environment.
Collapse
Affiliation(s)
- Anna V. Piterina
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| | - Aidan J. Cloonan
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| | - Claire L. Meaney
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| | - Laura M. Davis
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| | - Anthony Callanan
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| | - Michael T. Walsh
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| | - Tim M. McGloughlin
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland; E-Mails:
(A.V.P.);
(A.J.C.);
(C.L.M.);
(L.M.D.);
(A.C.);
(M.T.W.)
| |
Collapse
|
4
|
Kasyanov VA, Hodde J, Hiles MC, Eisenberg C, Eisenberg L, De Castro LEF, Ozolanta I, Murovska M, Draughn RA, Prestwich GD, Markwald RR, Mironov V. Rapid biofabrication of tubular tissue constructs by centrifugal casting in a decellularized natural scaffold with laser-machined micropores. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2009; 20:329-337. [PMID: 18807150 DOI: 10.1007/s10856-008-3590-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2007] [Accepted: 09/04/2008] [Indexed: 05/26/2023]
Abstract
Centrifugal casting allows rapid biofabrication of tubular tissue constructs by suspending living cells in an in situ cross-linkable hydrogel. We hypothesize that introduction of laser-machined micropores into a decellularized natural scaffold will facilitate cell seeding by centrifugal casting and increase hydrogel retention, without compromising the biomechanical properties of the scaffold. Micropores with diameters of 50, 100, and 200 mum were machined at different linear densities in decellularized small intestine submucosa (SIS) planar sheets and tubular SIS scaffolds using an argon laser. The ultimate stress and ultimate strain values for SIS sheets with laser-machined micropores with diameter 50 mum and distance between holes as low as 714 mum were not significantly different from unmachined control SIS specimens. Centrifugal casting of GFP-labeled cells suspended in an in situ cross-linkable hyaluronan-based hydrogel resulted in scaffold recellularization with a high density of viable cells inside the laser-machined micropores. Perfusion tests demonstrated the retention of the cells encapsulated within the HA hydrogel in the microholes. Thus, an SIS scaffold with appropriately sized microholes can be loaded with hydrogel encapsulated cells by centrifugal casting to give a mechanically robust construct that retains the cell-seeded hydrogel, permitting rapid biofabrication of tubular tissue construct in a "bioreactor-free" fashion.
Collapse
|
5
|
Lu SH, Sacks MS, Chung SY, Gloeckner DC, Pruchnic R, Huard J, de Groat WC, Chancellor MB. Biaxial mechanical properties of muscle-derived cell seeded small intestinal submucosa for bladder wall reconstitution. Biomaterials 2005; 26:443-9. [PMID: 15275818 DOI: 10.1016/j.biomaterials.2004.05.006] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Bladder wall replacement remains a challenging problem for urological surgery due to leakage, infection, stone formation, and extensive time needed for tissue regeneration. To explore the feasibility of producing a more functional biomaterial for bladder reconstitution, we incorporated muscle-derived cells (MDC) into small intestinal submucosa (SIS) scaffolds. MDC were harvested from mice hindleg muscle, transfected with a plasmid encoding for beta-galactosidase, and placed into single-layer SIS cell culture inserts. Twenty-five MDC and/or SIS specimens were incubated at 37 degrees C for either 10 or 20 days. After harvesting, mechanical properties were characterized using biaxial testing, and the areal strain under 1 MPa peak stress used to quantify tissue compliance. Histological results indicated that MDC migrated throughout the SIS after 20 days. The mean (+/-SE) areal strain of the 0 day control group was 0.182 +/- 0.027 (n=5). After 10 days incubation, the mean (+/-SE) areal strain in MDC/SIS was 0.247 +/- 0.014 (n=5) compared to 10 day control SIS 0.200 +/- 0.024 (n=6). After 20 days incubation, the mean areal strain of MDC/SIS was 0.255 +/- 0.019 (n=5) compared to control SIS 0.170 +/- 0.025 (n=5). Both 10 and 20 days seeded groups were significantly different (p=0.027) than that of incubated SIS alone, but were not different from each other. These results suggest that MDC growth was supported by SIS and that initial remodeling of the SIS ECM had occurred within the first 10 days of incubation, but may have slowed once the MDC had grown to confluence within the SIS.
Collapse
Affiliation(s)
- Shing-Hwa Lu
- Department of Urology, University of Pittsburgh, Pittsburgh, PA 15219, USA
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Freytes DO, Badylak SF, Webster TJ, Geddes LA, Rundell AE. Biaxial strength of multilaminated extracellular matrix scaffolds. Biomaterials 2004; 25:2353-61. [PMID: 14741600 DOI: 10.1016/j.biomaterials.2003.09.015] [Citation(s) in RCA: 152] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Xenogeneic extracellular matrix (ECM) can be harvested and configured to function as a bioscaffold for tissue and organ reconstruction. The mechanical properties of the ECM vary depending upon the tissue from which it is harvested. Likewise, the manufacturing steps required to develop ECMs into medical grade devices will affect the surface morphology and the mechanical properties of the bioscaffold; important properties for constructive tissue remodeling. The present study compared the ball-burst strength of five different ECM scaffolds before and after treatment with peracetic acid (PAA): porcine small intestinal submucosa (SIS), porcine urinary bladder submucosa (UBS), porcine urinary bladder matrix (UBM), a composite of UBS + UBM, and canine stomach submucosa (SS). This study also compared the mechanical properties of 2- and 4-layer ECM scaffolds. Results showed 2-layer SS devices had the highest ball-burst value of all 2-layer ECM devices. Moreover, all 4-layer ECM devices had similar ball-burst strength except for 4-layer UBM devices which was the weakest. PAA-treatment decreased the ball-burst strength of SS and increased the ball-burst strength of UBS 2-layer devices. This study showed the material properties of the ECM scaffolds could be engineered to mimic those of native soft tissues (i.e. vascular, musculotendinous, etc) by varying the number of layers and modifying the disinfection/sterilization treatments used for manufacturing.
Collapse
Affiliation(s)
- Donald O Freytes
- Department of Biomedical Engineering, Purdue University, West Lafayette, IN 47907-2022, USA
| | | | | | | | | |
Collapse
|
7
|
Sarikaya A, Record R, Wu CC, Tullius B, Badylak S, Ladisch M. Antimicrobial activity associated with extracellular matrices. TISSUE ENGINEERING 2002; 8:63-71. [PMID: 11886655 DOI: 10.1089/107632702753503063] [Citation(s) in RCA: 138] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Materials derived from extracellular matrices (ECMs) are being evaluated as scaffolds for surgical reconstruction of damaged or missing tissues. It is important to understand the susceptibility of these biological materials to bacterial infections. ECMs derived from porcine small intestinal submucosa (SIS) and urinary bladder submucosa (UBS) were found to possess antimicrobial activity. ECM extracts, obtained by digesting these acellular matrices in acetic acid, demonstrated antibacterial activity against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus. Antimicrobial activity was determined using a minimal inhibitory concentration assay. Bacteriostatic activity was detected at protein concentrations of ECM extracts equivalent to 0.77-1.60 mg/mL. ECM extracts were found to inhibit bacterial growth for up to at least 13 h. The resulting extracts consisted of water-soluble peptides and proteins with molecular weights ranging from <4 to >100 kDa and lower molecular weight compounds, as determined by size exclusion liquid chromatography.
Collapse
Affiliation(s)
- Ayda Sarikaya
- Laboratory of Renewable Resources Engineering, School of Veterinary Medicine, Purdue University, West Lafayette, Indiana 47907-1295, USA
| | | | | | | | | | | |
Collapse
|
8
|
Gloeckner DC, Sacks MS, Billiar KL, Bachrach N. Mechanical evaluation and design of a multilayered collagenous repair biomaterial. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2000; 52:365-73. [PMID: 10951377 DOI: 10.1002/1097-4636(200011)52:2<365::aid-jbm17>3.0.co;2-3] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
One method of fabricating implantable biomaterials is to utilize biologically derived, chemically modified tissues to form constructs that are both biocompatible and remodelable. Rigorous mechanical characterization is a necessary component in material evaluation to ensure that the constructs will withstand in vivo loading. In this study we performed an in-depth biaxial mechanical and quantitative structural analysis of GraftPatch (GP), a biomaterial constructed by assembling chemically treated layers of porcine small intestinal submucosa (SIS). The mechanical behavior of GP was compared to both native SIS and to glutaraldehyde-treated bovine pericardium (GLBP) as a reference biomaterial. Under biaxial loading, GP was found to be stiffer than native SIS and mechanically anisotropic, with the preferred fiber direction demonstrating greater stiffness. Quantitative structural analysis using small-angle light scattering indicated a uniform fiber structure similar to GLBP and SIS. To enable test-protocol-independent quantitative comparisons, the biaxial mechanical data were fit to an orthotropic constitutive model, which indicated a similar degree of mechanical anisotropy between the three groups. We also demonstrate how the constitutive model can be used to design layered biocomposite materials that can undergo large deformations.
Collapse
Affiliation(s)
- D C Gloeckner
- Tissue Mechanics Laboratory, Department of Bioengineering, 749 Benedum Hall, 3700 O'Hara Street, Pittsburgh, Pennsylvania 15261, USA
| | | | | | | |
Collapse
|
9
|
Badylak S, Liang A, Record R, Tullius R, Hodde J. Endothelial cell adherence to small intestinal submucosa: an acellular bioscaffold. Biomaterials 1999; 20:2257-63. [PMID: 10614932 DOI: 10.1016/s0142-9612(99)00156-8] [Citation(s) in RCA: 123] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Degradable biomaterials to be used as scaffolds for tissue repair will ideally be able to support new blood vessel growth. The present study evaluated the adherence of human dermal microvascular endothelial cells (HMECs) to an acellular resorbable scaffold material derived from the small intestinal submucosa (SIS). HMECs were exposed to hydrated and dehydrated forms of SIS and to plastic surfaces coated with one of four different known components of the SIS extracellular matrix: collagen Type I, collagen Type IV, fibronectin, and laminin. Results showed that adherence of HMECs to hydrated SIS was greater than to any of the other tested surfaces (P < 0.05). Exposure of HMECs to either soluble collagen Type IV or soluble fibronectin prior to exposure of these cells to hydrated SIS showed only partial inhibition of HMEC attachment. We conclude that HMECs find hydrated SIS to be a suitable substrate for adherence and that dehydration of SIS adversely affects the ability of HMECs to adhere in vitro. The cause of HMEC adherence to SIS appears to be a combination of both its composition and architecture.
Collapse
Affiliation(s)
- S Badylak
- Department of Biomedical Engineering, Purdue University, West Lafayette, IN 47097-1296, USA
| | | | | | | | | |
Collapse
|
10
|
Roeder R, Wolfe J, Lianakis N, Hinson T, Geddes LA, Obermiller J. Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 1999; 47:65-70. [PMID: 10400882 DOI: 10.1002/(sici)1097-4636(199910)47:1<65::aid-jbm9>3.0.co;2-f] [Citation(s) in RCA: 116] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Small-intestine submucosa (SIS) is cell-free collagen, 100 mu thick, derived from the small intestine. It has been used as a vascular graft and has the highly desirable property of remodeling itself to become host tissue. To date there has been limited reporting on its preimplantation mechanical properties as a vascular graft. In this study, compliance, elastic modulus, and burst pressure have been measured on 5- and 8-mm SIS grafts. The compliance (percent of diameter increase for a pressure rise from 80 to 120 mmHg) was 4.6% av (range 2.9 to 8.6%) for the 5-mm grafts. For the 8-mm graft, the increase in diameter for the same pressure rise was 8.7% av (range 7.2 to 9.5%). The modulus of elasticity (E) increased exponentially with increasing pressure according to E = E(o)e(alphaP), where Eo is the zero-pressure modulus and alpha is the exponent that describes the rate of increase in E with pressure; the units for E, Eo, and P are g/cm2. The mean value for Eo was 4106 (g/cm2 range 1348-5601). The mean value for alpha was 0.0059 (range 0.0028-0.0125). At 100 mmHg, the mean value for E was 8.91 x 10(3) g/cm2 (range 1.02-8.80 x 10(3)). The mean burst pressure for 5.5-mm grafts was 3517 mm Hg (range 2069-4654). In terms of preimplant compliance, the small-diameter SIS graft is about (1/2) as compliant as the dog carotid artery, about four times more compliant than a typical vein graft, and more than an order of magnitude more compliant than synthetic vascular grafts.
Collapse
Affiliation(s)
- R Roeder
- Department of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907-1296, USA
| | | | | | | | | | | |
Collapse
|
11
|
Sacks MS, Gloeckner DC. Quantification of the fiber architecture and biaxial mechanical behavior of porcine intestinal submucosa. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 1999; 46:1-10. [PMID: 10357130 DOI: 10.1002/(sici)1097-4636(199907)46:1<1::aid-jbm1>3.0.co;2-7] [Citation(s) in RCA: 120] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Porcine small intestinal submucosa (SIS) has been shown to serve as a remodelable tissue scaffold in a wide range of applications. Despite the large number of experimental studies, there is a lack of fundamental information on SIS anisotropic mechanical behavior and how this behavior changes postimplantation. As a first step in our study of remodeling biomaterials, we performed biaxial mechanical testing to quantify the anisotropic mechanical behavior and used small-angle light scattering (SALS) to quantify the gross fiber structure of fresh, unimplanted SIS. Structural results indicate that SIS displays primarily a single, continuous preferred fiber direction oriented parallel to the long axis of the intestine. Occasionally, two distinct fiber populations oriented at approximately +/-28 degrees with respect to the longitudinal axis could be distinguished. Consistent with this structure, SIS exhibited a nonlinear, anisotropic mechanical response with higher stresses along the longitudinal axis. Further, the circumferential stress-strain response was strongly affected by the maximum longitudinal strain level, but the maximum circumferential strain level only weakly affected the longitudinal stress-strain response. This asymmetric mechanical coupling suggests strong mechanical interactions on a fiber level. SIS stress-strain response also was similar to glutaraldehyde-treated bovine pericardium, attesting to the substantial strength of SIS in the fresh, untreated state. The results of this study will provide a basis for a future analysis of the structural and mechanical changes during the remodeling process.
Collapse
Affiliation(s)
- M S Sacks
- Department of Bioengineering, University of Pittsburgh, Pennsylvania 15260, USA
| | | |
Collapse
|
12
|
Kropp BP, Sawyer BD, Shannon HE, Rippy MK, Badylak SF, Adams MC, Keating MA, Rink RC, Thor KB. Characterization of small intestinal submucosa regenerated canine detrusor: assessment of reinnervation, in vitro compliance and contractility. J Urol 1996; 156:599-607. [PMID: 8683741 DOI: 10.1097/00005392-199608001-00008] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE We characterized small intestinal submucosa regenerated canine bladder. MATERIALS AND METHODS We subjected 15-month small intestinal submucosa regenerated canine bladder strips to in vitro muscle bath compliance, contractility testing and immunohistochemical staining. RESULTS Compliance studies demonstrated no significant difference between small intestinal submucosa regenerated and control bladders, which were 30-fold more compliant than native small intestinal submucosal graft material. Contractility studies demonstrated contractile responses and innervation similar to those of normal canine bladder. Afferent nerves were demonstrated through immunohistochemical techniques. CONCLUSIONS These characteristics further support the regenerative capacity of small intestinal submucosa and its potential use as a bladder augmentation material.
Collapse
Affiliation(s)
- B P Kropp
- Department of Urology, Riley Children's Hospital, Indiana University School of Medicine, Lafayette, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Kropp BP, Sawyer BD, Shannon HE, Rippy MK, Badylak SF, Adams MC, Keating MA, Rink RC, Thor KB. Characterization of Small Intestinal Submucosa Regenerated Canine Detrusor: Assessment of Reinnervation, in Vitro Compliance and Contractility. J Urol 1996. [DOI: 10.1016/s0022-5347(01)65761-6] [Citation(s) in RCA: 136] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|