1
|
Aguilar Pérez M, Henkes E, Hellstern V, Serna Candel C, Wendl C, Bäzner H, Ganslandt O, Henkes H. Endovascular Treatment of Anterior Circulation Aneurysms With the p64 Flow Modulation Device: Mid- and Long-Term Results in 617 Aneurysms From a Single Center. Oper Neurosurg (Hagerstown) 2021; 20:355-363. [PMID: 33469666 PMCID: PMC8133326 DOI: 10.1093/ons/opaa425] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 10/09/2020] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Flow diverters have become an important tool in the treatment of intracranial aneurysms, especially when dealing with difficult-to-treat or complex aneurysms. The p64 is the only fully resheathable and mechanically detachable flow diverter available for clinical use. OBJECTIVE To evaluate the safety and effectiveness of p64 for the treatment of intracranial saccular unruptured aneurysms arising from the anterior circulation over a long-term follow-up period. METHODS We retrospectively reviewed our prospectively maintained database to identify all patients who underwent treatment for an intracranial saccular (unruptured or beyond the acute hemorrhage phase) aneurysm arising from the anterior circulation with ≥1 p64 between December 2011 and December 2019. Fusiform aneurysms and dissections were excluded. Aneurysms with prior or concomitant saccular treatment (eg, coiling and clipping) were included. Aneurysms with parent vessel implants other than p64 were excluded. Anatomic features, intraprocedural complications, clinical outcome, as well as clinical and angiographic follow-ups were all recorded. RESULTS In total, 530 patients (388 females; median age 55.9 yr) with 617 intracranial aneurysms met the inclusion criteria. The average number of devices used per aneurysm was 1.1 (range 1-3). Mean aneurysm dome size was 4.8 mm (range 1-27 mm). Treatment-related morbimortality was 2.4%. Early, mid-term, and long-term angiographic follow-up showed complete or near-complete aneurysm occlusion in 76.8%, 89.7%, and 94.5%, respectively. CONCLUSION Treatment of intracranial saccular unruptured aneurysms of the anterior circulation using p64 is a safe and effective treatment option with high rate of occlusion at long-term follow-up and low morbimortality.
Collapse
Affiliation(s)
- Marta Aguilar Pérez
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Elina Henkes
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Victoria Hellstern
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Carmen Serna Candel
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Christina Wendl
- Institut für Röntgendiagnostik, Zentrum für Neuroradiologie, Universitätsklinikum Regensburg, Regensburg, Germany
| | - Hansjörg Bäzner
- Neurologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Oliver Ganslandt
- Neurochirurgische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Hans Henkes
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
- Medizinische Fakultät der Universität Duisburg-Essen, Essen, Germany
| |
Collapse
|
2
|
Aguilar Perez M, Hellstern V, Serna Candel C, Wendl C, Bäzner H, Gansladt O, Henkes H. Use of pCONUS HPC for the treatment of unruptured wide-necked bifurcation aneurysms: early clinical experience using single antiplatelet therapy. Stroke Vasc Neurol 2020; 6:57-64. [PMID: 32920538 PMCID: PMC8005901 DOI: 10.1136/svn-2020-000399] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 07/13/2020] [Accepted: 07/30/2020] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND In recent years, a growing number of stents and stent-like devices have become available to facilitate the treatment of challenging aneurysms. However, the need for dual antiplatelet therapy can limit their use, especially in ruptured aneurysms. The hydrophilic polymer coating (pHPC, phenox) is a novel glycan-based multilayer polymer that reduces platelet adhesion. This study aims to report our initial experience using the pCONUS HPC device for the treatment of unruptured wide-necked bifurcation aneurysms (WNBA) using acetylsalicylic acid (ASA) as single antiplatelet therapy (SAPT). METHODS We retrospectively identified all patients who were treated with the pCONUS HPC for unruptured WNBA in a multi-staged procedure using ASA as SAPT. Records were made of periprocedural complications, clinical outcome and angiographic and clinical follow-up. RESULTS We identified 15 patients with 15 WNBA. The average age was 69 years old (range, 41-76). Seven aneurysms were located in the middle cerebral artery, five in the anterior communicating artery, two at the basilar tip and one in the posterior communicating artery. Immediate post-treatment angiography showed five aneurysms with modified Raymond-Roy classification (mRRC) grade I and four aneurysms with mRRC grade II. There were no haemorrhagic complications. Four patients developed thrombus formation during the second treatment session, all of them completely resolving after administration of glycoprotein IIb/IIIa antagonists. Angiographic follow-up data were available for 10 patients and showed adequate occlusion (mRRC I or II) in eight aneurysms (80%). In-stent stenosis was observed in one patient whereas two patients showed de novo stenosis in one of the efferent branches. CONCLUSIONS This early experience on the use of the pCONUS HPC device suggests that it can be useful for treating unruptured WNBA under ASA as SAPT. Further investigation with a randomised treatment registry and larger cohort is needed.
Collapse
Affiliation(s)
- Marta Aguilar Perez
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Victoria Hellstern
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Carmen Serna Candel
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Christina Wendl
- Institut für Röntgendiagnostik, Zentrum für Neuroradiologie, Fakultät für Medizin der Universität Regensburg, Regensburg, Germany
| | - Hansjörg Bäzner
- Neurologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Oliver Gansladt
- Neurochirurgische, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany
| | - Hans Henkes
- Neuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.,Medizinische Fakultät, Universität Duisburg-Essen, Essen, Germany
| |
Collapse
|
3
|
Lenz-Habijan T, Bhogal P, Bannewitz C, Hannes R, Monstadt H, Simgen A, Mühl-Benninghaus R, Reith W, Henkes H. Prospective study to assess the tissue response to HPC-coated p48 flow diverter stents compared to uncoated devices in the rabbit carotid artery model. Eur Radiol Exp 2019; 3:47. [PMID: 31807964 PMCID: PMC6895370 DOI: 10.1186/s41747-019-0128-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 10/10/2019] [Indexed: 01/08/2023] Open
Abstract
Background Flow diverters (FDs) are widely used in the treatment of intracranial aneurysms, but the required medication increases the risk of haemorrhagic complications and limits their use in the acute setting. Surface modified FDs may limit the need for dual antiplatelet therapy (DAPT). Hydrophilic polymer coating (HPC) may reduce the need of medication. Methods This explorative study, approved by the local authorities and the local welfare committee, compared stent behaviour and overall tissue response between HPC-coated FDs and uncoated FDs, both implanted into the common carotid arteries of eight New Zealand white rabbits. Endothelialisation, inflammatory response, and performance during implantation were assessed. Angiographic follow-up was performed to observe the patency of the devices after implantation and after 30 days. Histological examinations were performed at 30 days to assess foreign body reaction and endothelialisation. Kruskal-Wallis and Wilcoxon tests were used to compare non-parametric variables. Results Angiography showed that both coated and uncoated FDs performed well during implantation. All devices remained patent during immediate follow-up and after 30 days. Histopathology showed no significant difference in inflammation within the vessel wall between the two cohorts (2.12 ± 0.75 vs. 1.96 ± 0.79, p = 0.7072). Complete endothelialisation of the stent struts was seen with very similar (0.04 ± 0.02 mm vs. 0.04 ± 0.03 mm, p = 0.892) neoendothelial thickness between the two cohorts after 30 days. Conclusion Taking into account the limitation in sample size, non-significant differences between the HPC-coated and uncoated FDs regarding implantation, foreign body response, and endothelialisation were found.
Collapse
Affiliation(s)
| | - Pervinder Bhogal
- Department of Interventional Neuroradiology, The Royal London Hospital, Whitechapel Road, London, E1 1BB, UK.
| | | | | | | | - Andreas Simgen
- Department of Neuroradiology, Saarland University, Homburg, Saar, Germany
| | | | - Wolfgang Reith
- Department of Neuroradiology, Saarland University, Homburg, Saar, Germany
| | - Hans Henkes
- Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany.,Medical Faculty, University Duisburg-Essen, Essen, Germany
| |
Collapse
|
4
|
Bhogal P, Bleise C, Chudyk J, Lylyk I, Perez N, Henkes H, Lylyk P. The p48_HPC antithrombogenic flow diverter: initial human experience using single antiplatelet therapy. J Int Med Res 2019; 48:300060519879580. [PMID: 31612765 PMCID: PMC7262863 DOI: 10.1177/0300060519879580] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Objective The p48 is a low-profile, intermediate-porosity flow diverter. phenox GmbH-trademarked hydrophilic polymer coating (pHPC) is a hydrophilic coating that has been shown in vitro to reduce the thrombogenicity of nitinol device surfaces. We performed the present study to determine whether the p48_HPC can be implanted using prasugrel alone. Methods We retrospectively identified all patients who were treated with the p48_HPC from January 2017 to December 2018 (n = 5) and underwent single antiplatelet therapy (SAPT) with prasugrel. P2Y12 inhibition was confirmed by the VerifyNow assay. The occurrence of thromboembolic and haemorrhagic complications was recorded alongside the occlusion rates of the treated aneurysms. Results All patients achieved adequate occlusion (Raymond–Roy Occlusion Classification I or II) during the follow-up period. No thromboembolic complications occurred. One patient developed a contained haematoma within the Sylvian fissure from the treated aneurysm 2 weeks postoperatively without clinical sequelae. Conclusions In this small series, no thromboembolic complications occurred in patients treated with the surface modified p48_HPC flow diverter and SAPT. Further studies with longer follow-up periods and larger cohorts should be performed.
Collapse
Affiliation(s)
- Pervinder Bhogal
- The Royal London Hospital, Whitechapel Road, London, UK
- Pervinder Bhogal, The Royal London Hospital, Whitechapel Road, London E1 1BB, UK.
| | - Carlos Bleise
- Clinica La Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - Jorge Chudyk
- Clinica La Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - Ivan Lylyk
- Clinica La Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - Nicolas Perez
- Clinica La Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - Hans Henkes
- Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany
- Medical Faculty, University Duisburg-Essen, Essen, Germany
| | - Pedro Lylyk
- Clinica La Sagrada Familia, ENERI, Buenos Aires, Argentina
| |
Collapse
|
5
|
Comparison of the Thrombogenicity of a Bare and Antithrombogenic Coated Flow Diverter in an In Vitro Flow Model. Cardiovasc Intervent Radiol 2019; 43:140-146. [PMID: 31410532 PMCID: PMC6940313 DOI: 10.1007/s00270-019-02307-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 08/05/2019] [Indexed: 12/25/2022]
Abstract
BACKGROUND Dual antiplatelet therapy is a pre-requisite for flow diverter (FD) implantation. The purpose of this study was to assess the thrombogenicity of the p48 FD, coated with the newly developed phenox Hydrophilic Polymer Coating (p48_HPC, phenox GmbH, Germany) in comparison with uncoated p48 FDs in an in vitro flow model (Chandler Loop). METHODS p48 and p48_HPC FDs were implanted into silicon tubes filled with whole human blood and incubated at 37 °C under pulsating flow. After 120 min, platelet count was determined in the blood. Platelet activation markers (PAR1) and formation of microparticles were analyzed in a flow cytometer. Fluorescence microscopy of CD42a positive cells and scanning electron microscopy was used to detect adherent platelets on the wire surface. RESULTS Platelets in contact with the uncoated p48 FDs are significantly more activated than those incubated with p48_HPC (73 ± 9% vs. 65 ± 6%, p < 0.05) and release more microparticles (1.8 ± 0.5 vs. 1.4 ± 0.4, p < 0.05). The platelet count after 120-min circulation in the Chandler Loop was significantly lower for the uncoated p48 compared to the p48_HPC indicating significantly greater adherence of the platelets to the p48 (71 ± 8% vs. 87 ± 5%, p < 0.05). SEM and fluorescent antibody imaging revealed minimal platelet adherence to the surface of the p48_HPC compared to the uncoated p48. CONCLUSION The pHPC coating significantly reduces thrombogenicity of the p48 FD. This may help to reduce the risk of thromboembolic complications when using these devices. A reduction in antiplatelet therapy may be possible.
Collapse
|
6
|
Hoemme A, Barth H, Haschke M, Krähenbühl S, Strasser F, Lehner C, von Kameke A, Wälti T, Thürlimann B, Früh M, Driessen C, Joerger M. Prognostic impact of polypharmacy and drug interactions in patients with advanced cancer. Cancer Chemother Pharmacol 2019; 83:763-774. [DOI: 10.1007/s00280-019-03783-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Accepted: 01/18/2019] [Indexed: 10/27/2022]
|
7
|
Bhogal P, AlMatter M, Hellstern V, Ganslandt O, Bäzner H, Henkes H, Aguilar-Pérez M. The Combined Use of Intraluminal and Intrasaccular Flow Diversion for the Treatment of Intracranial Aneurysms: Report of 25 Cases. Neurointervention 2018; 13:20-31. [PMID: 29535895 PMCID: PMC5847887 DOI: 10.5469/neuroint.2018.13.1.20] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2018] [Revised: 02/23/2018] [Accepted: 02/26/2018] [Indexed: 11/29/2022] Open
Abstract
PURPOSE The Medina Embolic Device (MED) is a new intrasaccular device with promising early results. Previously we documented our initial experience of this device both alone and in combination with other devices including flow diverter stents (FDS). We sought to determine the effect of the MED + FDS strategy for the treatment of selected aneurysms. MATERIALS AND METHODS We performed a retrospective analysis of prospectively collected data to identify all patients with aneurysms treated using both the MED and intraluminal FDS. We present our technical success rate, early and mid-term angiographic follow-up, and clinical outcome data. RESULTS We identified 25 non-consecutive patients. The treatment was staged in 9 patients and in a single session 16 patients. The average age was 61±12.8 years (range 40-82). The average fundus height was 11±3.6 mm and average fundus width was 10.1±3.4 mm. In the staged cohort (n=9) at delayed angiography (mean 10 mths) 8 aneurysms (89%) showed complete exclusion (mRRC 1) and in one patient there was a parent vessel occlusion. In the simultaneous cohort delayed angiography (n=10, mean 8.1 months) demonstrated complete occlusion (mRRC 1) in 6 aneurysms (60%), 3 neck remnants (mRRC 2) (30%) and 1 patient (10%) showed persistent aneurysmal filling (mRRC 3a). There were 5 complications with permanent morbidity (mRS >2) in two patients. There were no mortalities. CONCLUSION The MED can be successfully used in combination with intraluminal FDS and in selected aneurysms this may represent an alternative to FDS and adjunctive coiling.
Collapse
Affiliation(s)
- Pervinder Bhogal
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Germany
| | | | | | | | - Hansjörg Bäzner
- Neurological Clinic, Neurocenter, Klinikum Stuttgart, Germany
| | - Hans Henkes
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Germany
- Medical Faculty, University Duisburg-Essen, Germany
| | | |
Collapse
|