1
|
Stauss R, Savov P, Ettinger M. [New technologies in total knee arthroplasty : Current concepts and personalized treatment strategies]. ORTHOPADIE (HEIDELBERG, GERMANY) 2025; 54:190-198. [PMID: 39961906 DOI: 10.1007/s00132-025-04618-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 01/13/2025] [Indexed: 02/28/2025]
Abstract
BACKGROUND In total knee arthroplasty (TKA), there is a trend towards personalized concepts. This includes the implementation of new technologies and the increasing popularity of individualized alignment strategies. TARGETS The purpose of personalized TKA is to restore the patient's bony anatomy and constitutional alignment, as well as the physiological soft tissue balance and joint kinematics. Modern technologies facilitate a thorough, three-dimensional analysis of the bony structures and the patient's constitutional alignment. Virtual planning enables a simulation component placement, gap balancing and postoperative alignment. After approval of the surgical plan, the technology-aided execution shows a greater accuracy, precision and reproducibility of implant alignment compared to conventional manual instrumentation. OVERVIEW This article focuses on novel technologies in total knee arthroplasty, including patient-specific instrumentation (PSI), custom implants, navigation and robotics. The purpose of this article is to summarize current evidence, including radiological and functional outcomes, as well as economic aspects. Furthermore, the implementation of novel technologies in the context of personalized alignment strategies will be discussed.
Collapse
Affiliation(s)
- Ricarda Stauss
- Universitätsklinik für Orthopädie im Pius Hospital, Carl von Ossietzky Universität Oldenburg, Georgstraße 12, 26121, Oldenburg, Deutschland.
| | - Peter Savov
- Universitätsklinik für Orthopädie im Pius Hospital, Carl von Ossietzky Universität Oldenburg, Georgstraße 12, 26121, Oldenburg, Deutschland
| | - Max Ettinger
- Universitätsklinik für Orthopädie im Pius Hospital, Carl von Ossietzky Universität Oldenburg, Georgstraße 12, 26121, Oldenburg, Deutschland
| |
Collapse
|
2
|
Oh SM, Bin SI, Kim JM, Lee BS, Lee J, Bae K. Limb length change after total knee arthroplasty for valgus deformity does not affect the clinical score and is not affected by fixed flexion deformity. Orthop Traumatol Surg Res 2024; 110:103787. [PMID: 38070733 DOI: 10.1016/j.otsr.2023.103787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 10/31/2023] [Accepted: 12/05/2023] [Indexed: 12/17/2023]
Abstract
BACKGROUND The limb length change (LLC) after total knee arthroplasty (TKA) is especially significant in valgus deformity. The higher LLC could cause higher incidences of lower limb length discrepancy (LLD) and low clinical score. However, studies about LLC after TKA for valgus deformity are limited, and there are none on the relationship between LLC and fixed flexion deformity (FFD) in valgus deformity. HYPOTHESIS (1) The amount of LLC would affect the postoperative LLD, (2) the improvement of fixed flexion deformity (FFD) would affect the amount of LLC, (3) The amount of LLC would affect the improvement in the clinical score after TKA for valgus deformity. PATIENTS AND METHODS Fifty knees of 50 patients who underwent primary unilateral TKA for valgus-type osteoarthritis between January 2000 and October 2021 were included. A radiological and clinical assessment were performed the day before the operation and at 12 months post-operatively. Full-length standing anteroposterior radiographs were used to measure HKA and LLC. FFD and Hospital for Special Surgery (HSS) score were measured in the outpatient department. RESULTS The incidence of lengthening was 92.0% and the mean LLC was 18.85mm (SD, 19.60mm). Postoperative LLD over 10mm occurred in 26% and the mean of postoperative LLD was 4.21mm (SD, 7.96mm). The LLC was correlated with postoperative LLD (rs=0.357, p=0.011) and the HKA change (rs=0.375, p=0.007), but not with the FFD improvement (rs=0.164, p=0.255) and HSS improvement (rs=0.076, p=0.613) or postoperative HSS (rs=0.094, p=0.528). CONCLUSION LLC was affected by HKA improvement but not by FFD improvement after TKA for patients with valgus deformity. Additionally, LLC did not affect the clinical score. LEVEL OF EVIDENCE III; retrospective cohort study.
Collapse
Affiliation(s)
- Sung-Mok Oh
- Department of Orthopedic surgery, Barun Hospital, 145, Yeouidaebang-ro, Yeongdeungpo-gu, Seoul, Korea
| | - Seong-Il Bin
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, 05505 Seoul, Korea.
| | - Jong-Min Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, 05505 Seoul, Korea
| | - Bum-Sik Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, 05505 Seoul, Korea
| | - Jongjin Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, 05505 Seoul, Korea
| | - Kinam Bae
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, 05505 Seoul, Korea
| |
Collapse
|
3
|
Li S, Liu X, Chen X, Xu H, Zhang Y, Qian W. Development and Validation of an Artificial Intelligence Preoperative Planning and Patient-Specific Instrumentation System for Total Knee Arthroplasty. Bioengineering (Basel) 2023; 10:1417. [PMID: 38136008 PMCID: PMC10740483 DOI: 10.3390/bioengineering10121417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 11/29/2023] [Accepted: 12/12/2023] [Indexed: 12/24/2023] Open
Abstract
BACKGROUND Accurate preoperative planning for total knee arthroplasty (TKA) is crucial. Computed tomography (CT)-based preoperative planning offers more comprehensive information and can also be used to design patient-specific instrumentation (PSI), but it requires well-reconstructed and segmented images, and the process is complex and time-consuming. This study aimed to develop an artificial intelligence (AI) preoperative planning and PSI system for TKA and to validate its time savings and accuracy in clinical applications. METHODS The 3D-UNet and modified HRNet neural network structures were used to develop the AI preoperative planning and PSI system (AIJOINT). Forty-two patients who were scheduled for TKA underwent both AI and manual CT processing and planning for component sizing, 20 of whom had their PSIs designed and applied intraoperatively. The time consumed and the size and orientation of the postoperative component were recorded. RESULTS The Dice similarity coefficient (DSC) and loss function indicated excellent performance of the neural network structure in CT image segmentation. AIJOINT was faster than conventional methods for CT segmentation (3.74 ± 0.82 vs. 128.88 ± 17.31 min, p < 0.05) and PSI design (35.10 ± 3.98 vs. 159.52 ± 17.14 min, p < 0.05) without increasing the time for size planning. The accuracy of AIJOINT in planning the size of both femoral and tibial components was 92.9%, while the accuracy of the conventional method in planning the size of the femoral and tibial components was 42.9% and 47.6%, respectively (p < 0.05). In addition, AI-based PSI improved the accuracy of the hip-knee-ankle angle and reduced postoperative blood loss (p < 0.05). CONCLUSION AIJOINT significantly reduces the time needed for CT processing and PSI design without increasing the time for size planning, accurately predicts the component size, and improves the accuracy of lower limb alignment in TKA patients, providing a meaningful supplement to the application of AI in orthopaedics.
Collapse
Affiliation(s)
- Songlin Li
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100010, China
| | - Xingyu Liu
- School of Life Sciences, Tsinghua University, Beijing 100084, China
- Institute of Biomedical and Health Engineering (iBHE), Tsinghua Shenzhen International Graduate School, Shenzhen 518000, China
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xi Chen
- Departments of Orthopedics, West China Hospital, West China School of Medicine, Sichuan University, Chengdu 610041, China
| | - Hongjun Xu
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100010, China
| | - Yiling Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Wenwei Qian
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100010, China
| |
Collapse
|
4
|
Keskinis A, Paraskevopoulos K, Diamantidis DE, Ververidis A, Fiska A, Tilkeridis K. The Role of 3D-Printed Patient-Specific Instrumentation in Total Knee Arthroplasty: A Literature Review. Cureus 2023; 15:e43321. [PMID: 37700954 PMCID: PMC10493459 DOI: 10.7759/cureus.43321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/11/2023] [Indexed: 09/14/2023] Open
Abstract
Total knee arthroplasty (TKA) is currently one of the most common orthopedic surgeries due to the ever-increasing average life expectancy. The constant need for effective and accurate techniques was contributed to the development of three-dimensional (3D) printing in that field, especially for patient-specific instrumentation (PSI) and custom-made implants fabrication. PSI may offer numerous benefits, such as resection accuracy, mechanical axis alignment, cost-effectiveness, and time economy. Nonetheless, the results of existing studies are controversial. For this purpose, a review article of the published articles was conducted to summarize the role of 3D-printed PSI in TKA.
Collapse
Affiliation(s)
- Anthimos Keskinis
- Orthopedic Surgery Department, University General Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, GRC
| | - Konstantinos Paraskevopoulos
- Orthopedic Surgery Department, University General Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, GRC
| | | | - Athanasios Ververidis
- Orthopedic Surgery Department, University General Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, GRC
| | - Aliki Fiska
- Anatomy Laboratory, Democritus University of Thrace, Alexandroupolis, GRC
| | - Konstantinos Tilkeridis
- Orthopedic Surgery Department, University General Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, GRC
| |
Collapse
|
5
|
Tibesku CO, Haas SB, Saunders C, Harwood DA. Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis. Arch Orthop Trauma Surg 2023; 143:4379-4393. [PMID: 36449066 PMCID: PMC10293358 DOI: 10.1007/s00402-022-04698-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 11/10/2022] [Indexed: 12/05/2022]
Abstract
INTRODUCTION Malalignment and resulting complications are major challenges in total knee arthroplasty (TKA) which patient-specific instrumentation (PSI) is proposed to alleviate. Previous PSI meta-analyses of TKA outcomes typically do not differentiate between PSI systems and assess relatively few outcomes, so the value of their findings is limited. VISIONAIRE™ cutting guides (Smith + Nephew Inc., Memphis, TN, USA) is a PSI system based on preoperative magnetic resonance and X-ray imaging. A systematic literature review (SLR) and meta-analysis, focussed specifically on VISIONAIRE, were conducted to assess TKA accuracy, intraoperative outcomes, and postoperative outcomes, compared with conventional instrumentation (CI). MATERIALS AND METHODS The SLR was performed using PubMed, Embase, and Google Scholar databases to identify relevant studies published until March 2022. Depending on statistical heterogeneity, meta-analyses were performed for outcome measures with fixed effect (I2 < 50%) or random-effects models (I2 ≥ 50%). Dichotomous outcomes were reported as odds ratios and continuous outcomes were reported as mean differences. Descriptive analyses were performed for outcomes not amenable to meta-analysis. RESULTS Outcomes for VISIONAIRE versus CI were reported in 25 studies. Compared with CI, VISIONAIRE reduced odds of mechanical outliers by 40% (p < 0.0001), with no statistically significant differences in odds of overall coronal, sagittal, or rotational plane component outliers. VISIONAIRE improved surgical efficiency (operating room, turnover, and tourniquet times reduced by 7.3% (p = 0.02), 42% (p = 0.022), and 15.9% (p = 0.01), respectively), lowering the odds of blood transfusion by 53% (p = 0.01) and shortening patients' hospital stays (11.1% reduction; p < 0.0001). There were no significant differences between groups in incidence of postoperative complications and (descriptively analyzed) return-to-function outcomes. CONCLUSION Options for PSI in TKA differ substantially, and it is important to assess the outcomes of individual systems. The current findings suggest that VISIONAIRE guides can lead to improved alignment accuracy and surgical efficiency compared with CI, without compromising postoperative safety and return-to-function outcomes.
Collapse
Affiliation(s)
| | - Steven B Haas
- Knee Surgery, Hospital for Special Surgery, Weill Cornell Medical College, New York, NY, USA
| | | | | |
Collapse
|
6
|
Hinloopen JH, Puijk R, Nolte PA, Schoones JW, de Ridder R, Pijls BG. The efficacy and safety of patient-specific instrumentation in primary total knee replacement: a systematic review and meta-analysis. Expert Rev Med Devices 2023; 20:245-252. [PMID: 36736371 DOI: 10.1080/17434440.2023.2177152] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
INTRODUCTION Patient-specific instrumentation (PSI) for primary total knee arthroplasty (TKA) surgery has been shown to increase accuracy of component positioning. However, it is unclear whether this also translates to actual benefits for patients in terms of better outcomes (efficacy) or less complications such as revisions (safety). We therefore systematically reviewed the literature to determine the efficacy and safety of PSI in primary TKA. METHODS Randomized controlled trials comparing PSI to non-PSI in primary TKA were included. A random effects model was used with meta-regression in case of heterogeneity. RESULTS Forty-three studies were included with a total of 1816 TKA in the PSI group and 1887 TKA in the control group. There were no clinically relevant differences between the PSI-group and non-PSI group regarding all outcomes. There was considerable heterogeneity: meta-regression analyses showed that the year the study was published was an important effect modifier. Early publications tended to show a positive effect for PSI compared to non-PSI TKA, whereas later studies found the opposite. CONCLUSION Based on evidence of moderate certainty, our study suggested that there were no clinically relevant differences in efficacy and safety between patients treated with PSI TKA and patients treated with non-PSI TKA.
Collapse
Affiliation(s)
- J H Hinloopen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - R Puijk
- Department of Orthopedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - P A Nolte
- Department of Orthopedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands.,Department Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - J W Schoones
- Directorate of Research Policy (Formerly: Walaeus Library), Leiden University Medical Centre, Leiden, The Netherlands
| | - R de Ridder
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.,Department of Orthopaedics, Reinier Haga Orthopaedic Centre, Zoetermeer, Netherlands
| | - B G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
7
|
Pereira EG, Carvalho MM, Oliveira T, Sacramento T, Cruz H, Viegas R, Fontes AP, Marreiros A, Sousa JP. Benefits of Tranexamic Acid in Total Knee Arthroplasty: A Classification and Regression Tree Analysis in Function of Instrumentation, BMI, and Gender. J Knee Surg 2023; 36:173-180. [PMID: 34225366 DOI: 10.1055/s-0041-1731455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Tranexamic acid (TXA) is an antifibrinolytic drug that reduces blood loss in patients that undergo Total knee arthroplasty (TKA). Few studies compare its effect on conventional instrumentation (CI) versus patient-specific instrumentation (PSI). The main objective of this study was to understand analytically how TXA usage in both instrumentations influenced blood loss in TKA differently and see if the differences seen could be explained by the patient's body mass index (BMI) and gender. This nonrandomized retrospective study sample consisted of 688 TKA procedures performed on patients who had symptomatic arthrosis resistant to conservative treatment. Descriptive analysis was used to evaluate blood loss using hemoglobin (Hb) mean values and mean variation (%). The Classification and Regression Tree (CRT) method was applied to understand how the independent variables affected the dependent variable. Comparing patients submitted to the same instrumentation, where some received TXA and others did not, patients that received TXA had lower blood loss. Comparing patients who underwent TKA with different instrumentations and without the use of TXA, it was found that patients who underwent TKA with PSI had lower blood loss than those who underwent TKA with CI. However, when these same instruments were compared again, but associated with the use of TXA, the opposite was true with patients undergoing TKA with PSI showing greater blood loss than patients undergoing TKA with CI. TXA usage in TKA is significantly beneficial in minimizing blood loss and regardless of instrumentation. When using TXA, the lowest blood loss was obtained in patients with higher BMI and submitted to TKA with CI. This is most likely explained by the synergistic antifibrotic effect of TXA with adipokines, such as plasminogen activator inhibitor-1 (PAI-1), found in the femoral bone marrow which is perforated using CI. If, however, TXA wasn't used, the lowest blood loss was obtained in patients submitted to TKA with PSI.
Collapse
Affiliation(s)
- Eduardo G Pereira
- Universidade do Algarve-Faculdade de Medicina e Ciências Biomédicas, Campus de Gambelas Faro, Portugal
| | - Maria M Carvalho
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Tiago Oliveira
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Telmo Sacramento
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Henrique Cruz
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Rui Viegas
- Departamento de Ortopedia e Traumatologia, Hospital Beatriz Ângelo, Loures, Portugal
| | - Ana P Fontes
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Ana Marreiros
- Universidade do Algarve-Faculdade de Medicina e Ciências Biomédicas, Campus de Gambelas Faro, Portugal.,Algarve Biomedical Center - Research Institute (ABC-RI)-Faculdade de Medicina e Ciência Biomédicas, Campus de Gambelas Faro, Portugal
| | - João P Sousa
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| |
Collapse
|
8
|
León-Muñoz VJ, López-López M, Santonja-Medina F. Patient-specific instrumentation makes sense in total knee arthroplasty. Expert Rev Med Devices 2022; 19:489-497. [PMID: 35903900 DOI: 10.1080/17434440.2022.2108320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) surgery was initially developed to increase accuracy. The potential PSI benefits have expanded in the last decade, and other advantages have been published. However, different authors are critical of PSI and argue that the advantages are not such and do not compensate for the extra cost. This article aims to describe the recently published advantages and disadvantages of PSI. AREAS COVERED Narrative description of the latest publications related to PSI in accuracy, clinical and functional outcomes, operative time, efficiency, and other benefits. EXPERT COMMENTARY We have published high accuracy of the system, with a not clinically relevant loss of accuracy, significantly higher precision with PSI than with conventional instruments, and a high percentage of cases in the optimal range and similar to that obtained with computer-assisted navigation, greater imprecision for tibial slope, a significant blood loss reduction, and time consumption, an acceptable and non-significant increase in the cost per procedure and no difference in complications during hospital admission and at 90 days. We think that PSI will not follow the Scott Parabola and that it will continue to be a valuable type of device in some instances of TKA surgery.
Collapse
Affiliation(s)
- Vicente J León-Muñoz
- Department of Orthopedic Surgery and Traumatology. Hospital General Universitario Reina Sofía. Murcia (Spain)
| | - Mirian López-López
- Subdirección General de Tecnologías de la Información. Servicio Murciano de Salud. Murcia (Spain)
| | - Fernando Santonja-Medina
- Department of Orthopedic Surgery and Traumatology. Hospital Clínico Universitario Virgen de la Arrixaca. Murcia (Spain).,Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia. Murcia (Spain)
| |
Collapse
|
9
|
Correlation between Surface Area Ratio of Medial to Lateral Tibial Plateau and Knee Alignment in Adults. Curr Med Sci 2022; 42:577-583. [DOI: 10.1007/s11596-022-2590-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Accepted: 01/07/2022] [Indexed: 11/03/2022]
|
10
|
董 子, 李 杨, 田 华. [Research progress on comparison of the application effects between personal specific instrumentation and computer-assisted navigation surgery in total knee arthroplasty]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:1492-1498. [PMID: 34779179 PMCID: PMC8586758 DOI: 10.7507/1002-1892.202104048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 09/13/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To compare the application effects between personal specific instrumentation (PSI) and computer-assisted navigation surgery (CAS) in total knee arthroplasty (TKA). METHODS The literature comparing the application effects of PSI and CAS in TKA in recent years was widely consulted, and the difference between PSI-TKA and CAS-TKA in operation time, lower limb alignment, blood loss, and knee function were compared. RESULTS Compared to CAS-TKA, PSI-TKA simplifies operation procedures and shortens operation time but probably has worse lower limb alignment. It is still controversial in comparison of perioperative blood loss and knee function between two techniques. CONCLUSION PSI-TKA and CAS-TKA both have advantages and disadvantages, and their differences need to be confirmed by further high-quality clinical trial.
Collapse
Affiliation(s)
- 子漾 董
- 北京大学第三医院骨科(北京 100191)Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P.R.China
- 骨与关节精准医学教育部工程研究中心(北京 100191)Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, P.R.China
| | - 杨 李
- 北京大学第三医院骨科(北京 100191)Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P.R.China
- 骨与关节精准医学教育部工程研究中心(北京 100191)Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, P.R.China
| | - 华 田
- 北京大学第三医院骨科(北京 100191)Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P.R.China
- 骨与关节精准医学教育部工程研究中心(北京 100191)Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, P.R.China
| |
Collapse
|
11
|
Patientenspezifische Instrumentierung und Totalendoprothesen am Knie. ARTHROSKOPIE 2021. [DOI: 10.1007/s00142-021-00460-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Zusammenfassung
Hintergrund
Die patientenspezifische Instrumentierung (PSI) ist eine vielversprechende neue Technologie in der orthopädischen Chirurgie, die das Ziel verfolgt, die Implantationstechnik der Knietotalendoprothese (Knie-TEP) im Vergleich zur konventionellen Instrumentierung zu vereinfachen und präziser zu machen. Ziel dieses Artikels ist es, Vorteile und Grenzen der PSI für die primäre Knie-TEP zu beschreiben.
Material und Methoden
Es erfolgte eine umfassende Literaturrecherche zum Thema PSI in der Knieprothetik hinsichtlich Evidenz für Planung, Präzision, klinische Ergebnisse, intraoperative Parameter sowie Kosten und Effizienz.
Ergebnisse
Die dreidimensionale Computertomographie (CT) weist in der präoperativen Planung der Knie-TEP eine höhere Genauigkeit auf als 2‑D-Röntgenaufnahmen. Die meisten Arbeiten postulierten keine signifikanten Effekte zugunsten der Genauigkeit der PSI gegenüber der Standard-Knie-TEP. Aber sie berichteten auch nicht, dass die Genauigkeit mit PSI schlechter sei. Hinsichtlich des klinischen Outcomes gibt es genügend Konsens unter den veröffentlichten Studien, um festzuhalten, dass es kurz- und mittelfristig keinen Unterschied zwischen Patienten gibt, die mit PSI oder konventioneller Technik operiert wurden. Eine große Metaanalyse konnte weder eine kürzere Operationszeit noch eine geringere Komplikationsrate für die PSI-Knie-TEP feststellen. Lediglich der intraoperative Blutverlust erwies sich als niedriger im Vergleich zur Standardtechnik, jedoch mit unveränderter Transfusionsrate. Kosteneffektivitätsanalysen lassen schlussfolgern, dass die PSI aktuell (noch) nicht kosteneffektiv ist.
Diskussion
Obwohl die aktuell vorliegenden Studienergebnisse die PSI-Technologie hinsichtlich vieler messbaren Kriterien nicht eindeutig von der Standardtechnik abheben, zeigt die PSI viele theoretische und praktische Vorteile.
Collapse
|
12
|
Sezer HB, Bohu Y, Hardy A, Lefevre N. Knee Prosthesis in the Computer Era. Orthop Surg 2021; 13:395-401. [PMID: 33506615 PMCID: PMC7957434 DOI: 10.1111/os.12762] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 06/24/2020] [Accepted: 06/25/2020] [Indexed: 12/11/2022] Open
Abstract
Over the past two decades, computer assistance has revolutionalized surgery and has enabled enormous advancements in knee prosthesis surgery. Total knee arthroplasty (TKA) is a hot topic of orthopaedic research. Reflecting population dynamics, its use continues to increase, especially in high demand populations. Therefore, efforts to achieve the best fit and precise alignment in TKA continue. Computer assistance is valuable for knee prosthesis surgeons in this regard. This manuscript investigated the use of computer assistance in knee prosthesis surgery. The effects of computer use on important facets of knee prosthesis surgery, such as precision, clinical aspects, and costs, were examined. Moreover, an overall review of the recent literature on the navigation and personalized cutting guides was conducted.
Collapse
Affiliation(s)
| | - Yoann Bohu
- Clinique du Sport Paris VParisFrance
- Institut de L'Appareil Locomoteur NolletParisFrance
| | - Alexandre Hardy
- Clinique du Sport Paris VParisFrance
- Institut de L'Appareil Locomoteur NolletParisFrance
| | - Nicolas Lefevre
- Clinique du Sport Paris VParisFrance
- Institut de L'Appareil Locomoteur NolletParisFrance
| |
Collapse
|
13
|
Massé V, Ghate RS. Using standard X-ray images to create 3D digital bone models and patient-matched guides for aiding implant positioning and sizing in total knee arthroplasty. Comput Assist Surg (Abingdon) 2021; 26:31-40. [PMID: 33721547 DOI: 10.1080/24699322.2021.1894239] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
X-Atlas™ is a new imaging technology intended to advance the state of the art in patient-specific instrumentation. It uses standard AP and lateral radiographs instead of CT or MRI scans to create 3D bone models, which can be used to perform pre-operative surgical planning and fabricate TKA personalized guides. The aim of this study was to validate X-Atlas™ and evaluate the accuracy of personalized guides created with this imaging technology. Its ability to predict implant size was also determined. The accuracy of the X-Atlas™ imaging technology was evaluated by comparing the landmarks of X-Atlas™ 3D Bone models to MRI-reconstructed bone models. The accuracy of PSI guides created with X-Atlas™ (X-PSI™ guides) was evaluated during a validation study (16 specimen knees) and a clinical study (50 patients; Health Canada #CSU2015-12K). Optical navigation was used to measure positioning accuracy. In addition, the ability of X-Atlas™ to predict implant size was assessed. The accuracy of the X-Atlas™ imaging technology was below 0.87 and 1.28 mm for the femoral and tibial landmarks, respectively. The accuracy of X-PSI™ guides to reproduce the pre-operative planned HKA was within ± 3° in 100% and 86.1% of cases, for the laboratory and clinical study respectively, which was significantly better than historical data for conventional instrumentation. X-Atlas™ was able to predict implant size to ± 1 size in 95.6% and 100%, for the femur and tibia component respectively. The X-Atlas™ imaging technology demonstrated excellent accuracy for reconstructing a 3D bone model. The results show that PSI guides created with X-Atlas™ (X-PSI™ guides) provide greater implant positioning accuracy than conventional instrumentation, without the requirement of advanced imaging. Furthermore, the X-Atlas™ imaging technology could effectively predict implant sizing, potentially reducing the number of instrument trays and improving surgical efficiency.
Collapse
Affiliation(s)
- Vincent Massé
- Department of Orthopaedic Surgery, Maisonneuve-Rosemont Hospital, Montreal University, Montreal, Canada
| | - Raju S Ghate
- Department of Orthopaedic Surgery, NorthShore University HealthSystem, Skokie, IL, USA.,Pritzker School of Medicine, The University of Chicago, Chicago, IL, USA
| |
Collapse
|
14
|
Li Z, Yang Z, Liao W, Wang W, Zou Y, Pan Y, Feng Z. Fewer femoral rotational outliers produced with CT- than with MRI-based patient-specific instrumentation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:2930-2941. [PMID: 31435705 DOI: 10.1007/s00167-019-05678-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 08/02/2019] [Indexed: 01/27/2023]
Abstract
PURPOSE Previous studies comparing the surgical accuracy between computed tomography (CT)- and magnetic resonance imaging (MRI)-based patient-specific instrumentation (PSI) methods have produced contradictory results. The aim of this study was to determine which is the more reliable imaging method (CT versus MRI) for patient-specific total knee arthroplasty (TKA). CT-based PSI is hypothesised to have an advantage regarding the number of outliers. METHODS A total of 22 randomised controlled trials (RCTs), including 1749 TKA cases, were eligible for the meta-analysis. RCTs, systematic reviews and meta-analyses on this topic published in databases before September 2018 were identified by a literature search. The primary outcome was the number of lower extremities with greater than 3° of difference in alignment angles between the postoperative outcomes and target outcomes. The parameters calculated from the meta-analysis included risk ratios (RRs) and 95% confidence intervals (CIs). Additionally, the publication bias and heterogeneity of the studies were assessed. RESULTS The risk of femoral rotational outliers in the PSI group (RR = 0.48; 95% CI 0.24-0.98) was significantly reduced. Furthermore, subgroup analysis showed that the accuracy in the CT-based PSI group was significantly higher than that in the MRI-based CSI group (RR = 0.31; 95% CI 0.10-0.92). CONCLUSION This meta-analysis shows that when performing TKA with PSI, preoperative CT is beneficial for the production of the PSI, resulting in a significantly lower proportion of outliers in femoral rotational alignment. CT should be the preferred choice for imaging when performing TKA surgery with PSI to obtain better femoral rotational alignment. LEVEL OF EVIDENCE Therapeutic study (systematic review and meta-analysis), Level I.
Collapse
Affiliation(s)
- Zhihao Li
- Guangzhou University of Traditional Chinese Medicine, No. 12, Jichang Road, Baiyun District, Guangzhou, 510403, Guangdong, People's Republic of China
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Zhidong Yang
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Wencui Liao
- The Liuzhou Hospital of Traditional Chinese Medicine, No. 32, Jiefang North Road, Chengzhong District, Liuzhou, 545000, Guangxi, People's Republic of China
| | - Weigang Wang
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Yonggen Zou
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Yaocheng Pan
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Zongquan Feng
- Guangzhou University of Traditional Chinese Medicine, No. 12, Jichang Road, Baiyun District, Guangzhou, 510403, Guangdong, People's Republic of China.
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China.
| |
Collapse
|
15
|
Matar HE, Platt SR, Gollish JD, Cameron HU. Overview of Randomized Controlled Trials in Total Knee Arthroplasty (47,675 Patients): What Have We Learnt? J Arthroplasty 2020; 35:1729-1736.e1. [PMID: 32088054 DOI: 10.1016/j.arth.2020.01.065] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Revised: 01/20/2020] [Accepted: 01/22/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of this study is to provide an overview of randomized controlled trials (RCTs) in primary total knee arthroplasty summarizing the available high-quality evidence. METHODS Following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, we searched the Cochrane Central Register of Controlled Trials (CENTRAL, 2019, Issue 3), Ovid MEDLINE, and Embase. We excluded nonrandomized trials, trials on unicompartmental knee arthroplasty or revision surgery, systematic reviews, and meta-analyses. Trials that met our inclusion criteria were assessed using a binary outcome measure of whether they reported statistically significant findings. These were then classified according to the intervention groups (surgical approach, tourniquet use, design, etc.). RESULTS Four hundred and three RCTs met the inclusion criteria and were included. The total number of patients in those 403 RCTs was 47,675. Only 33 RCTs (8.2%) reported significant differences between the intervention and the control groups. The trials were grouped into surgical approach 34, tourniquet 31, minimally invasive surgery 13, patient specific instrumentation 30, knee design 37, fixation 27, mobile bearing 47, navigation 50, polyethylene 19, technique 27, patella resurfacing 26, drain 19, closure 16, and others 27 RCTs. CONCLUSION For the vast majority of patients, a standard conventional total knee arthroplasty with a surgical approach familiar to the surgeon using standard well-established components, with or without tourniquet, without surgical drain leads to satisfactory long-term clinical outcomes.
Collapse
Affiliation(s)
- Hosam E Matar
- Sunnybrook Holland Centre, University of Toronto, Toronto, ON, Canada; Holland Orthopaedic & Arthritic Centre, Sunnybrook Health Sciences, University of Toronto, Toronto, ON, Canada
| | - Simon R Platt
- Department of Orthopaedic Surgery, Gold Coast University Hospital, Southport, Queensland, Australia
| | - Jeffrey D Gollish
- Holland Orthopaedic & Arthritic Centre, Sunnybrook Health Sciences, University of Toronto, Toronto, ON, Canada
| | - Hugh U Cameron
- Holland Orthopaedic & Arthritic Centre, Sunnybrook Health Sciences, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
16
|
Turgeon TR, Cameron B, Burnell CD, Hedden DR, Bohm ER. A double-blind randomized controlled trial of total knee replacement using patient-specific cutting block instrumentation versus standard instrumentation. Can J Surg 2020; 62:460-467. [PMID: 31782643 DOI: 10.1503/cjs.018318] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Background Patient-specific cutting blocks in total knee arthroplasty have been promoted to improve mechanical alignment, reduce alignment outliers and improve patient outcomes. The aim of this study was to compare the efficacy of patient-specific instrumentation (PSI) and conventional instrumentation (CI) in achieving neutral alignment and accurate component positioning in total knee arthroplasty. Methods We conducted a double-blinded randomized controlled trial in which patients were randomly assigned to treatment with either PSI or CI. Results Fifty-four patients were included in the study. No relevant improvement in coronal alignment was found between the PSI and CI groups with post-hoc power of 0.91. Tibial slope was found to be more accurately reproduced to the preoperative target of 3° with PSI than with CI (3.8°± 3.1° v. 7.7°± 3.6°, respectively, p < 0.001). There were no differences found in patient-reported outcome measures, surgical time or length of hospital stay. Conclusion Given the added cost of the PSI technique, its use is difficult to justify given the small improvement in only a single alignment parameter. Clinical trial registration Clinicaltrials.gov, no. NCT03416946
Collapse
Affiliation(s)
- Thomas R. Turgeon
- From the Department of Surgery, Section of Orthopaedics, Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); the Concordia Joint Replacement Group, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); and the Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Cameron)
| | - Brett Cameron
- From the Department of Surgery, Section of Orthopaedics, Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); the Concordia Joint Replacement Group, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); and the Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Cameron)
| | - Colin D. Burnell
- From the Department of Surgery, Section of Orthopaedics, Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); the Concordia Joint Replacement Group, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); and the Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Cameron)
| | - David R. Hedden
- From the Department of Surgery, Section of Orthopaedics, Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); the Concordia Joint Replacement Group, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); and the Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Cameron)
| | - Eric R. Bohm
- From the Department of Surgery, Section of Orthopaedics, Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); the Concordia Joint Replacement Group, Winnipeg, Man. (Turgeon, Burnell, Hedden, Bohm); and the Max Rady College of Medicine, University of Manitoba, Winnipeg, Man. (Cameron)
| |
Collapse
|
17
|
Patient-Specific or Conventional Instrumentations: A Meta-analysis of Randomized Controlled Trials. BIOMED RESEARCH INTERNATIONAL 2020; 2020:2164371. [PMID: 32258107 PMCID: PMC7085852 DOI: 10.1155/2020/2164371] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Accepted: 02/13/2020] [Indexed: 02/05/2023]
Abstract
Objective To conduct a meta-analysis of randomized controlled trials (RCTs) to compare knee arthroplasty with patient-specific instrumentation (PSI) with the conventional instrumentation (CI). Methods RCTs were selected in PubMed and Embase from 2012 to 2018. Key data extracted included malalignment of mechanical axis, blood loss, surgical time, Oxford Knee Score (OKS), Knee Society Score (KSS), length of stay, and complications. Subgroup analysis was also performed regarding different PSI systems and different image processing methods. Results 29 RCTs with 2487 knees were eligible for the meta-analysis. Results showed that PSI did not improve the alignment of the mechanical axis compared with CI, but MRI-based PSI and Visionaire-specific PSI decrease the risk of malalignment significantly (P = 0.04 and P = 0.04 and P = 0.04 and P = 0.04 and P = 0.04 and Conclusion PSI reduced the blood loss and improved KSS. MRI-based PSI reduced operative time and risk of malalignment of mechanical axis compared with CT-based PSI. Moreover, Visionaire-specific PSI achieves better alignment result of the mechanical axis than other systems.
Collapse
|
18
|
Kizaki K, Shanmugaraj A, Yamashita F, Simunovic N, Duong A, Khanna V, Ayeni OR. Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis. BMC Musculoskelet Disord 2019; 20:561. [PMID: 31759392 PMCID: PMC6875166 DOI: 10.1186/s12891-019-2940-2] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 11/11/2019] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Total knee arthroplasty using patient-specific instrumentation (TKA-PSI), which are disposable cutting block guides generated to fit each patient's 3-dimensional knee anatomy, has been developed to treat patients with end-stage osteoarthritis of the knee. Surrogate markers such as radiographic malalignment have been well investigated, however, patient-important outcomes are not well examined to elucidate the efficacy of TKA-PSI. The aim of this review is to determine if TKA-PSI improves patient-reported outcome measures (PROM), surgery time, blood loss, transfusion and complications (e.g. surgical site infection, deep venous thrombosis, and revision TKA). METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and ongoing clinical trials. For PROMs, surgery time, blood loss, and transfusion rate, we included randomized controlled trials (RCT) comparing TKA-PSI and standard TKA to treat osteoarthritis of the knee. For complications, we also included non-randomized comparative studies (non-RCT). RESULTS This review includes 38 studies, 24 of which were RCT and 14 of which were non-RCT. These included a total of 3487 patients. The predominant population in the included studies highly reflected the general population, with 62% being female, aged over 60 and having end-stage osteoarthritis of the knee. TKA-PSI did not improve PROMs as compared to standard TKA for less than 1-year (mean difference 0.48, 95% confidence interval (CI) -1.92-0.97 in the Oxford knee score, mean 3-month follow-up) and for 1-year or more (mean difference 0.25, 95%CI - 4.39-4.89 in the WOMAC score, mean 29-month follow-up). TKA-PSI did not reduce surgery time (mean difference - 3.09 min, 95%CI -6.73-0.55). TKA-PSI decreased blood loss with a small effect size corresponding to a 0.4 g/dl hemoglobin decrease (95%CI 0.18-0.88), but did not decrease transfusion rate (risk difference - 0.04, 95%CI -0.09-0.01). TKA-PSI did not reduce complication rates (risk difference 0.00, 95%CI - 0.01-0.01 in the composite outcome). CONCLUSIONS TKA-PSI does not improve patient-reported outcome measures, surgery time, and complication rates as compared to standard TKA. TKA-PSI decreases blood loss with a small effect, which is not enough to reduce transfusion rate.
Collapse
Affiliation(s)
- Kazuha Kizaki
- Department of Health Research Methods, Evidence, and Impact, McMaster University Medical Centre, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada.,Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Ajaykumar Shanmugaraj
- Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Fumiharu Yamashita
- Department of Orthopaedic surgery and rheumatology, Kyoto Shimogamo Hospital, 17 Shimogamo, Kyoto, 606-0866, Japan
| | - Nicole Simunovic
- Department of Health Research Methods, Evidence, and Impact, McMaster University Medical Centre, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada.,Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Andrew Duong
- Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Vickas Khanna
- Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Olufemi R Ayeni
- Department of Health Research Methods, Evidence, and Impact, McMaster University Medical Centre, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada. .,Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada.
| |
Collapse
|
19
|
León-Muñoz V, Lisón-Almagro A, López-López M. Influence of instrumentation on the surgical time to implant a total knee prosthesis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2019. [DOI: 10.1016/j.recote.2019.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
20
|
Harold RE, Macleod J, Butler BA, Sullivan R, Beal MD, Manning DW. Single-Use Custom Instrumentation in Total Knee Arthroplasty: Effect on In-Hospital Complications, Length of Stay, and Discharge Disposition. Orthopedics 2019; 42:299-303. [PMID: 30964541 DOI: 10.3928/01477447-20190403-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Accepted: 10/29/2018] [Indexed: 02/03/2023]
Abstract
Total knee arthroplasty (TKA) is a quality surgical intervention with rapidly increasing use. This growth has brought with it a host of new technologies, including custom instrumentation (CI). With the current emphasis on value-based health care, the clinical benefit of CI TKA must be evaluated. The goal of this study was to compare CI and conventional TKA regarding multiple quality metrics, in-hospital complications, length of stay, and discharge destination. The authors propensity score matched 231 conventional TKAs to 231 consecutive CI TKAs for age, sex, and body mass index. Preoperative risk factors analyzed were age, sex, body mass index, and preoperative hemoglobin. Perioperative factors included transfusion rate, hemoglobin drop, hemovac output, operative time, length of stay, discharge disposition, deep venous thrombosis and pulmonary embolism rates, and in-hospital vital sign data. There were no differences in preoperative demographics between groups. Postoperatively, there was no difference between conventional and CI TKA in operative time, transfusion rate, discharge hemoglobin, length of stay, discharge disposition, or in-hospital venous thromboembolism rates. In the conventional and CI groups, length of stay was 2.6 and 2.5 days (P=.43) and discharge disposition was 82% home and 83% home (P=.90), respectively. Although CI TKA is commonly implemented, in this analysis, compared with conventional TKA, it was not associated with any difference in length of stay, discharge disposition, operative time, transfusion rate, or in-hospital complications. [Orthopedics. 2019; 42(5):299-303.].
Collapse
|
21
|
Randelli PS, Menon A, Pasqualotto S, Zanini B, Compagnoni R, Cucchi D. Patient-Specific Instrumentation Does Not Affect Rotational Alignment of the Femoral Component and Perioperative Blood Loss in Total Knee Arthroplasty: A Prospective, Randomized, Controlled Trial. J Arthroplasty 2019; 34:1374-1381.e1. [PMID: 30979672 DOI: 10.1016/j.arth.2019.03.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 02/17/2019] [Accepted: 03/06/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Proposed aims of patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) are to improve accuracy of component alignment, while reducing blood loss and surgical time. The primary goal of this prospective, randomized, controlled, clinical trial is to verify whether PSI improves the rotational alignment of the femoral component in comparison to conventionally implanted TKA. METHODS One-hundred thirty-three consecutive patients were assessed for eligibility. Block randomization was performed to allocated patients in the treatment (PSI) or control group. During hospital stay, surgical times were recorded, and total blood volume loss and estimated red blood cell were calculated. Two months after surgery, a computed tomography of the knee was obtained to measure femoral component rotation to the transepicondylar axis and tibial component slope. RESULTS Sixty-nine patients were enrolled. PSI did neither result in a significant improvement in femoral component rotation nor result in a reduction of outliers, as compared with conventional instrumentation. No significant improvement in terms of tibial slope, blood loss, total surgical time, and ischemia time could be identified. The number of tibial recuts required in the PSI group was significantly higher than in the control group (P = .0003). CONCLUSION PSI does not improve the accuracy of femoral component rotation in TKA in comparison to conventional instrumentation. Moreover, PSI did not appear to influence any of the other variables investigated as secondary goals by this study. The results of this study do not support its routine use during standard TKA. LEVEL OF EVIDENCE Level I, randomized, controlled trial.
Collapse
Affiliation(s)
- Pietro S Randelli
- Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy; 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan, Italy
| | - Alessandra Menon
- Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy; 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan, Italy
| | - Stefano Pasqualotto
- Divisione di Ortopedia e Traumatologia, IRCCS Ospedale Classificato Equiparato Sacro Cuore - Don Calabria, Negrar, Italy
| | - Beatrice Zanini
- Dipartimento di Scienze della Salute, Università del Piemonte Orientale A. Avogadro, Novara, Italy
| | - Riccardo Compagnoni
- 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan, Italy
| | - Davide Cucchi
- Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy; Department of Orthopaedics and Trauma Surgery, Universitätsklinikum Bonn, Bonn, Germany
| |
Collapse
|
22
|
León-Muñoz VJ, Lisón-Almagro AJ, López-López M. Influence of instrumentation on the surgical time to implant a total knee prosthesis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2019; 63:321-326. [PMID: 31182387 DOI: 10.1016/j.recot.2019.04.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 03/26/2019] [Accepted: 04/07/2019] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE To demonstrate if there is a difference in the time that the surgery is prolonged to implant a knee prosthesis according to the instrumentation system used. MATERIAL AND METHODS Retrospective analysis of the duration of 243 interventions (skin-to-skin time and ischemia time) performed by the same surgeon. Seventy-two cases operated with conventional instruments (IC), 68 by means of computer assisted surgery (CAS) and 103 with personalized instrumentation system (PSI). RESULTS IC skin-to-skin time 87,85 min (SD 11,86). IC ischemia time 94,44 min (SD 11,49). Computer assisted surgery skin-to-skin time 123,46 min (SD 11,27). Computer assisted surgery ischemia time 129,63 min (SD 11,37). PSI skin-to-skin time 78,69 min (SD 13,06). PSI ischemia time 84,63 min (SD 12,06). There is a significant difference between PSI and the other instrumentation systems (p 0,000). CONCLUSIONS In our study, the time consumption for the implantation of a knee prosthesis has been significantly lower when cutting blocks have been used, than when we have used other systems.
Collapse
Affiliation(s)
- V J León-Muñoz
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, España.
| | - A J Lisón-Almagro
- Servicio de Cirugía Ortopédica y Traumatología, Hospital de la Vega Lorenzo Guirao, Cieza, Murcia, España
| | - M López-López
- Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Murcia, España
| |
Collapse
|
23
|
León-Muñoz VJ, Martínez-Martínez F, López-López M, Santonja-Medina F. Patient-specific instrumentation in total knee arthroplasty. Expert Rev Med Devices 2019; 16:555-567. [PMID: 31154870 DOI: 10.1080/17434440.2019.1627197] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) is one of the most commonly performed orthopedic procedures. During the past decade, patient-specific instrumentation (PSI) has been commercially introduced in order to simplify and make TKA surgery more effective, precise and efficient than conventional mechanical instrumentation (CI) and computer-assisted surgery (CAS). Nevertheless, there are critical arguments against PSI for routine use. The aim of the current manuscript is to describe advantages and limitations of PSI for primary TKA. AREAS COVERED By means of a description of the available literature different aspects are discussed (accuracy, clinical and functional outcomes, operative time, blood loss, efficiency and costs). EXPERT OPINION Most publications do not claim a significant increase in PSI accuracy over CI, but they also do not postulate PSIs accuracy is worse either. Regarding clinical aspects, PSI did not appear to give any advantage over standard techniques although, equally, it did not appear to show any disadvantages. PSI seems to reduce operative time, could reduce perioperative blood loss and provides logistical benefits in the operation room. Further studies will be required to more thoroughly assess all the advantages and disadvantages of this promising technology as an alternative to CI and CAS.
Collapse
Affiliation(s)
- Vicente J León-Muñoz
- a Orthopaedic Surgery and Traumatology Department , Hospital Clínico Universitario Virgen de la Arrixaca , Murcia , Spain
| | - Francisco Martínez-Martínez
- a Orthopaedic Surgery and Traumatology Department , Hospital Clínico Universitario Virgen de la Arrixaca , Murcia , Spain.,b Faculty of Medicine , University of Murcia , Murcia , Spain
| | - Mirian López-López
- c Subdirección General de Tecnologías de la Información. Servicio Murciano de Salud , Murcia , Spain
| | - Fernando Santonja-Medina
- a Orthopaedic Surgery and Traumatology Department , Hospital Clínico Universitario Virgen de la Arrixaca , Murcia , Spain.,b Faculty of Medicine , University of Murcia , Murcia , Spain
| |
Collapse
|
24
|
Gong S, Xu W, Wang R, Wang Z, Wang B, Han L, Chen G. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2019; 27:1083-1095. [PMID: 30377714 PMCID: PMC6435625 DOI: 10.1007/s00167-018-5256-0] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Accepted: 10/19/2018] [Indexed: 12/29/2022]
Abstract
PURPOSE The purpose of the present study was to compare patient-specific instrumentation (PSI) with standard instrumentation (SI) in patients undergoing total knee arthroplasty (TKA). PSI is hypothesized to have advantages with respect to component alignment; number of outliers (defined as alignment > 3° from the target alignment); operative time; perioperative blood loss; and length of hospital stay. This new surgical technique is expected to exhibit superior performance. METHODS A total of 23 randomized controlled trials (RCTs) involving 2058 knees that compared the clinical outcomes of TKA between PSI and SI were included in the present analysis; these RCTs were identified via a literature search of the PubMed, Embase, and Cochrane Library databases through March 1, 2018. The outcomes of interest included coronal, sagittal and axial component alignment (presented as the angle of deviation from the transcondylar line); number of outliers; operative time; perioperative blood loss; and length of hospital stay. RESULTS There was a significant difference in postoperative femoral axial alignment between PSI and SI patients (95% CI - 0.71 to - 0.21, p = 0.0004, I2 = 48%). PSI resulted in approximately 0.4° less deviation from the transcondylar line than SI. Based on our results, PSI reduced operative time by a mean of 7 min compared with SI (95% CI - 10.95 to - 3.75, p < 0.0001, I2 = 78%). According to the included literature, PSI reduced perioperative blood loss by approximately 90 ml compared with SI (95% CI - 146.65 to - 20.18, p = 0.01, I2 = 74%). We did not find any differences between PSI and SI with respect to any other parameters. CONCLUSIONS PSI has advantages in axial alignment of the femoral component, operative time, and perioperative blood loss relative to SI. No significant differences were found between PSI and SI with respect to alignment of the remaining components, number of outliers, or length of hospital stay. LEVEL OF EVIDENCE Therapeutic study (systematic review and meta-analysis), Level I.
Collapse
Affiliation(s)
- Song Gong
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Weihua Xu
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
| | - Ruoyu Wang
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Zijian Wang
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Bo Wang
- 0000 0004 0368 7223grid.33199.31Department of Rehabilitation, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Lizhi Han
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Guo Chen
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| |
Collapse
|
25
|
Klasan A, Dworschak P, Heyse TJ, Lahner M, Malcherczyk D, Efe T, El-Zayat BF. Patient-specific instruments’ routine use over conventional total knee arthroplasty remains inconclusive: Analysis of 961 cases. Technol Health Care 2018; 26:523-528. [DOI: 10.3233/thc-171167] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Antonio Klasan
- Center for Orthopaedics and Traumatology, University Clinic Marburg, Marburg, Germany
| | - Philipp Dworschak
- Center for Orthopaedics and Traumatology, University Clinic Marburg, Marburg, Germany
| | - Thomas J. Heyse
- Center for Orthopaedics and Traumatology, University Clinic Marburg, Marburg, Germany
| | - Matthias Lahner
- Joint Center Hilden, Ruhr-University Bochum, Bochum, Germany
| | - Dominik Malcherczyk
- Center for Orthopaedics and Traumatology, University Clinic Marburg, Marburg, Germany
| | - Turgay Efe
- Center for Orthopaedics and Traumatology, University Clinic Marburg, Marburg, Germany
| | - Bilal Farouk El-Zayat
- Center for Orthopaedics and Traumatology, University Clinic Marburg, Marburg, Germany
| |
Collapse
|
26
|
Kosse NM, Heesterbeek PJC, Schimmel JJP, van Hellemondt GG, Wymenga AB, Defoort KC. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 2018; 26:1792-1799. [PMID: 29181560 DOI: 10.1007/s00167-017-4792-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Accepted: 11/06/2017] [Indexed: 11/30/2022]
Abstract
PURPOSE The primary aim of the study was to examine stability and alignment after total knee arthroplasty (TKA) using patient-specific instrumentation (PSI) and conventional instrumentation (CI). The hypothesis was that stability and alignment would be better using PSI than CI, 12 months postoperatively. The secondary aim included the evaluation of clinical outcomes after TKA. METHODS In this prospective randomized controlled trial, 42 patients with knee osteoarthritis received a Genesis II PS prosthesis with either PSI or CI. Patients visited the hospital preoperatively and postoperatively after 6 weeks and 3 and 12 months. To evaluate stability, varus-valgus laxity was determined in extension and flexion using stress radiographs 12 months postoperatively. Three months postoperatively, a long-leg radiograph and CT scan were obtained to measure hip-knee-ankle (HKA) alignment and component rotation. Furthermore, frontal and sagittal alignment of the components, the Knee Society Score, VAS Pain, VAS Satisfaction, Knee injury and Osteoarthritis Outcome score, Patella score (Kujala), University of California Los Angeles activity score, anterior-posterior laxity, (serious) adverse device-related events, and intraoperative complications were reported. The clinical outcomes were compared using independent t tests or non-parametric alternatives, and repeated measurements ANOVA with a significance level of p < 0.05. RESULTS No significant differences were found between the two groups regarding stability, HKA angle, and rotational alignment. In four patients, the PSI did not fit correctly on the tibia and/or femur requiring intraoperative modifications. Both groups improved significantly over time on all clinical outcomes, with no significant differences between the groups 12 months postoperatively. The PSI group showed less tibial slope than the patients in the CI group [PSI 2.6° versus CI 4.8° (p = 0.02)]. Finally, the PSI group more frequently received a thinner insert size than the CI group (p = 0.03). CONCLUSIONS Patients operated with PSI did not differ from CI in terms of stability and alignment. However, in the PSI group ligament releases were more often required intraoperatively. Furthermore, the two methods did not show different clinical results. It seems that the preoperative planning for the PSI facilitates more conservative bone cuts than CI, but whether this is clinically relevant should be investigated. Since PSI is more expensive and time consuming than CI, and does not outperform CI with regard to clinical results, we recommend to use CI. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Nienke M Kosse
- Sint Maartenskliniek Research, Sint Maartenskliniek, P.O. Box 9011, 6500 GM, Nijmegen, The Netherlands.
| | - Petra J C Heesterbeek
- Sint Maartenskliniek Research, Sint Maartenskliniek, P.O. Box 9011, 6500 GM, Nijmegen, The Netherlands
| | - Janneke J P Schimmel
- Sint Maartenskliniek Research, Sint Maartenskliniek, P.O. Box 9011, 6500 GM, Nijmegen, The Netherlands
| | | | - Ate B Wymenga
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Koen C Defoort
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, The Netherlands
| |
Collapse
|
27
|
Chen SC, Zeng YM, Yan MN, Yue B, Zhang J, Wang Y. Effect of Femoral Component Flexion Implantation on the Mediolateral Bone-prosthetic Fit in Total Knee Arthroplasty. Orthop Surg 2017; 9:91-96. [PMID: 28371503 DOI: 10.1111/os.12319] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Accepted: 02/13/2016] [Indexed: 11/27/2022] Open
Abstract
OBJECTIVE Femoral component overhang in total knee arthroplasty (TKA) has been reported in previous studies. The purpose of this study was to evaluate the effect of femoral component flexion implantation on mediolateral bone-prosthetic fit in TKA. METHODS Virtual prosthesis implantations were performed on computed tomographic models of 10 Chinese knees with femoral prostheses of the Advance Medial-Pivot knee system (MicroPort Orthopedics, Arlington, TN, USA), with the femoral component positioned at 0°, 3°, or 6° of flexion in the sagittal plane. For each degree of flexion implantation, the differences between the knee and femoral component models on the lateral and medial sides at trochlea (zone 1), anterior-distal condyle (zone 2), posterior-distal condyle (zone 3), and posterior condyle (zone 4) were measured. Positive difference values indicate component overhang, and negative difference values indicate component underhang. The values of component overhang (underhang) in each zone were statistically analyzed across the 3° of flexion implantation. RESULTS With a greater degree of flexion implantation, overhang was reduced and even changed to underhang. With 0° of flexion implantation, an overhang exceeding 3 mm existed mainly on the medial side of zone 1 (5.81 mm) and the lateral side of zone 2 (3.39 mm). With 3° of flexion, overhang exceeding 3 mm was observed only on the medial side of zone 1 (3.10 mm), and underhang was observed only on the medial side of zone 4 (-0.32 mm). No overhang exceeding 3 mm was observed for 6° of flexion, while underhang was observed except on the lateral sides of zone 2 (1.32 mm) and zone 4 (1.10 mm) and on the medial side of zone 1 (1.54 mm). A significant difference in overhang values on the lateral and medial sides of zone 1 was observed between 0 and 6° of flexion (P < 0.05). CONCLUSION The present study demonstrated that femoral component flexion implantation by 3° can reduce excessive overhang, although 3.10 mm of overhang remained at the medial side of zone 1. Conversely, 6° of flexion implantation can avoid 3 mm of overhang for any zone, but increases the risk of underhang. Slight flexion implantation may be an effective alternative technique to prevent excessive component overhang, especially in the trochlea and anterior region of the distal condyle, in Chinese patients with standard TKA prostheses.
Collapse
Affiliation(s)
- Shi-Chang Chen
- Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Yi-Ming Zeng
- Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Meng-Ning Yan
- Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Bing Yue
- Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Jun Zhang
- Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - You Wang
- Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| |
Collapse
|
28
|
Beal MD, Delagramaticas D, Fitz D. Improving outcomes in total knee arthroplasty-do navigation or customized implants have a role? J Orthop Surg Res 2016; 11:60. [PMID: 27216272 PMCID: PMC4877731 DOI: 10.1186/s13018-016-0396-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Accepted: 05/07/2016] [Indexed: 01/15/2023] Open
Abstract
Modern total knee arthroplasty is effective at treating the pain and disability associated with osteoarthritis. The number of total knee replacements done in the USA continues to increase. Despite the great care taken during all of these procedures, some patients remain dissatisfied with their outcome. While this dissatisfaction is likely multifactorial, malalignment of the prosthetic components is a major cause of postoperative complications. A neutral mechanical axis plus or minus 3° is felt to have a positive impact on the survivorship of the prosthesis. Conventional instrumentation has been shown to have a significant number of total knee replacements that lie well outside a neutral coronal alignment. With that in mind, significant effort has been placed into the development of technology to improve the overall alignment of the prosthesis. In order to reduce the number of outliers, several companies have developed cost-effective systems to aid the surgeon in achieving a more predictably aligned prosthesis in all three planes. We will review the literature that is available regarding several of these tools to examine if navigation or custom guides improve outcomes in total knee arthroplasty. Our review supports that while both navigation and custom implants guides seem to be a cost effective way to achieve a predictable mechanical alignment of a total knee prosthesis therefore reducing the number of outliers, the cost may be increased operative times with no perceived difference in patient satisfaction with navigation custom guides.
Collapse
Affiliation(s)
- Matthew D Beal
- Northwestern University Feinberg School of Medicine, Chicago, USA.
| | | | - David Fitz
- Northwestern University Feinberg School of Medicine, Chicago, USA
| |
Collapse
|