1
|
Lo TS, Harun F, Jhang LS, Hsieh WC, Loong Tan Y, Alzabedi A. Modified surelift anterior-apical transvaginal mesh for advanced urogenital prolapse: Retrospective surgical, functional and sonographic outcomes at 3 years. Eur J Obstet Gynecol Reprod Biol 2025; 304:1-8. [PMID: 39541615 DOI: 10.1016/j.ejogrb.2024.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2024] [Revised: 09/25/2024] [Accepted: 11/05/2024] [Indexed: 11/16/2024]
Abstract
OBJECTIVE This study evaluates the outcomes of modified transvaginal mesh (TVM) Surelift in managing advanced pelvic organ prolapse (POP) over a 3-year follow-up period, focusing on surgical success, functional improvement, and sonographic findings. METHODS A retrospective review was conducted on 99 women who underwent Surelift System surgery for advanced POP Stage III and IV between July 2018 to January 2020. Objective evaluation included Pelvic Organ Prolapse Quantification (POP-Q), multichannel urodynamic (UDS), and introital 2D ultrasonographic measurement. Subjective evaluation uses validated questionnaires of Incontinence Impact Questionnaire-7(IIQ-7), Urogenital Distress Inventory-6(UDI-6), Pelvic Organ Prolapse Distress Inventory 6(POPDI-6), Colorectal Anal Distress Inventory-8(CRADI-8) and Pelvic organ prolapse/ Urinary Incontinence Sexual Questionnaire (PISQ-12). Outcomes were examined at 3 months, yearly and at 3 years postoperative. Secondary outcome included de novo or persistent urodynamic stress incontinence (USI) and surgical complications. RESULTS Eighty-five women were included in the final analysis. At 3 years postoperative, the objective cure rate was 94.1 % and subjective cure rate of 91.8 %. Ultrasonography revealed initial mesh elongation and thickening at first year, resolving by the third year, while the distance between the bladder neck and mesh remained stable. Significant improvement in POP-Q components (Aa,Ba,C,Ap,Bp and TVL of p < 0.001), UDS (p < 0.001) and all validated Quality of Life (QoL) questionnaires (p < 0.001) were seen. De Novo USI and persistent USI occurred in 31.5 %. Complications included vaginal mesh exposure requiring excision in 4.7 % of patients, and one intraoperative bladder injury corrected promptly. CONCLUSION The Surelift System TVM demonstrates safety and efficacy in treating advanced anterior-apical POP, achieving high cure rates, secured mesh placement, and minimal complications at 3 years post-operative.
Collapse
Affiliation(s)
- Tsia-Shu Lo
- Division of Urogynecology, Department of Obstetrics and Gynecology, Linkou, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan; Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Taipei, Medical Center, Taipei, Taiwan; Chang Gung University, School of Medicine, Taoyuan, Taiwan.
| | - Fazlin Harun
- Department of Obstetrics and Gynecology, Women and Children Hospital (Hospital Tunku Azizah), Kuala Lumpur, Malaysia
| | - Lan-Sin Jhang
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Tucheng, Medical Center, Taipei, Taiwan
| | - Wu-Chiao Hsieh
- Division of Urogynecology, Department of Obstetrics and Gynecology, Linkou, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan; Chang Gung University, School of Medicine, Taoyuan, Taiwan
| | - Yiap Loong Tan
- Department of Obstetrics and Gynecology, Kuching Specialist Hospital, KPJ Healthcare Group, Sarawak, Malaysia
| | - Aisha Alzabedi
- Women Health Center, International Medical Center (IMC) Hospital, Jeddah, Saudi Arabia
| |
Collapse
|
2
|
Caramazza D, Campagna G, Moro F, Vacca L, Marturano M, Pizzacalla S, Trivellizzi IN, Panico G, Scambia G, Ercoli A, Testa AC. Transobturator tape versus single incision sling: how are they different? Clinical outcomes and ultrasonographic features of two mid-urethral slings. World J Urol 2022; 40:2521-2528. [PMID: 35982168 DOI: 10.1007/s00345-022-04109-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 07/17/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE Stress urinary incontinence (SUI) is usually treated with mid-urethral slings. The best approach is still debated and the relationship between slings and pelvic structures is not completely understood. The aim of this study is to identify any difference between trans-obturator tape (TOT) and single incision sling (minisling). METHODS Patients submitted to TOT or minisling were included in the study. Q-tip and stress test, ICIQ-SF questionnaire, PGI-I validated score, and 2D/3D transvaginal ultrasound parameters were collected at 1- and 6-month follow-up. Correlations between ultrasound parameters and clinical outcomes, PGI-I and ICIq-SF, were performed. RESULTS 61 patients were included in the study. PGI-I score was significantly lower in the minisling group than in TOT group at 1-month (p = 0.016) and 6-month follow-up (p = 0.076). The median distance between the sling and the lumen of urethra was significantly higher and the angle between the branches of the sling was significantly narrower in the minisling group. There were significant differences in distances between the sling and the bladder neck at 1-month and 6-month follow-up. An inverse correlation between angle of the branches and the Q-tip test was observed (p = 0.059 Pearson's Rho - 0.578). PGI-I correlated also with angle of the branches (p = 0.009, Pearson's Rho 0.503). CONCLUSION Patients undergoing TOT or minisling are similarly satisfied but show differences at ultrasound exam at 1- and 6-month follow-up. Pelvic floor ultrasound could be used in a short-term follow-up to visualize the sling position and to plan the most appropriate follow-up strategy.
Collapse
Affiliation(s)
- Daniela Caramazza
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC Uroginecologia e Medicina e Chirurgia Ricostruttiva Pelvica Femminile, Rome, Italy
| | - Giuseppe Campagna
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC Uroginecologia e Medicina e Chirurgia Ricostruttiva Pelvica Femminile, Rome, Italy
| | - Francesca Moro
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC di Ginecologia Oncologica, Rome, Italy.
| | - Lorenzo Vacca
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC Uroginecologia e Medicina e Chirurgia Ricostruttiva Pelvica Femminile, Rome, Italy
| | - Monia Marturano
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC Uroginecologia e Medicina e Chirurgia Ricostruttiva Pelvica Femminile, Rome, Italy
| | - Sara Pizzacalla
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC Uroginecologia e Medicina e Chirurgia Ricostruttiva Pelvica Femminile, Rome, Italy
| | | | - Giovanni Panico
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC Uroginecologia e Medicina e Chirurgia Ricostruttiva Pelvica Femminile, Rome, Italy
| | - Giovanni Scambia
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC di Ginecologia Oncologica, Rome, Italy
| | - Alfredo Ercoli
- PID Ginecologia Oncologica e Chirurgia Ginecologica Mininvasiva, Università degli Studi di Messina, Policlinico G. Martino, Messina, Italy
| | - Antonia Carla Testa
- Dipartimento di Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario A. Gemelli-IRCCS, UOC di Ginecologia Oncologica, Rome, Italy.,Dipartimento di Scienze della Vita e di Sanità Pubblica, Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
3
|
Knight KM, King GE, Palcsey SL, Suda A, Liang R, Moalli PA. Mesh Deformation: a mechanism underlying polypropylene prolapse mesh complications in vivo. Acta Biomater 2022; 148:323-335. [PMID: 35671876 DOI: 10.1016/j.actbio.2022.05.051] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 05/12/2022] [Accepted: 05/31/2022] [Indexed: 12/12/2022]
Abstract
Polypropylene meshes used in pelvic organ prolapse (POP) repair are hampered by complications. Most POP meshes are highly unstable after tensioning ex vivo, as evidenced by marked deformations (pore collapse and wrinkling) that result in altered structural properties and material burden. By intentionally introducing collapsed pores and wrinkles into a mesh that normally has open pores and remains relatively flat after implantation, we reproduce mesh complications in vivo. To do this, meshes were implanted onto the vagina of rhesus macaques in nondeformed (flat) vs deformed (pore collapse +/- wrinkles) configurations and placed on tension. Twelve weeks later, animals with deformed meshes had two complications, 1) mesh exposure through the vaginal epithelium, and 2) myofibroblast proliferation with fibrosis - a mechanism of pain. The overarching response to deformed mesh was vaginal thinning associated with accelerated apoptosis, reduced collagen content, increased proteolysis, deterioration of mechanical integrity, and loss of contractile function consistent with stress shielding - a precursor to mesh exposure. Regional differences were observed, however, with some areas demonstrating myofibroblast proliferation and matrix deposition. Variable mechanical cues imposed by deformed meshes likely induce these two disparate responses. Utilizing meshes associated with uniform stresses on the vagina by remaining flat with open pores after tensioning is critical to improving outcomes. STATEMENT OF SIGNIFICANCE: Pain and exposure are the two most reported complications associated with the use of polypropylene mesh in urogynecologic procedures. Most meshes have unstable geometries as evidenced by pore collapse and wrinkling after tensioning ex vivo, recapitulating what is observed in meshes excised from women with complications in vivo. We demonstrate that collapsed pores and wrinkling results in two distinct responses 1) mesh exposure associated with tissue degradation and atrophy and 2) myofibroblast proliferation and matrix deposition consistent with fibrosis, a tissue response associated with pain. In conclusion, mesh deformation leads to areas of tissue degradation and myofibroblast proliferation, the likely mechanisms of mesh exposure and pain, respectively. These data corroborate that mesh implantation in a flat configuration with open pores is a critical factor for reducing complications in mesh-augmented surgeries.
Collapse
Affiliation(s)
- Katrina M Knight
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Magee-Womens Research Institute, Pittsburgh, PA.
| | | | | | - Amanda Suda
- School of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Rui Liang
- Magee-Womens Research Institute, Pittsburgh, PA; Department of Obstetrics, Gynecology and Reproductive Sciences, University of Pittsburgh, Pittsburgh, PA
| | - Pamela A Moalli
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Department of Obstetrics, Gynecology and Reproductive Sciences, University of Pittsburgh, Pittsburgh, PA; Division of Urogynecology and Reconstructive Pelvic Surgery, Magee-Womens Hospital of the University of Pittsburgh, Pittsburgh, PA
| |
Collapse
|
4
|
Zhang L, Zhao Z, Chen J, Ma Y, Zhang G, Zhu L. Path-related pain after implantation of anterior transvaginal mesh: perspective from anatomical study. Int Urogynecol J 2022; 33:2551-2556. [PMID: 35034164 DOI: 10.1007/s00192-021-04924-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 06/11/2021] [Indexed: 01/05/2023]
Abstract
INTRODUCTION AND HYPOTHESIS Pelvic organ prolapse (POP) is a common gynecological disease caused by defects in pelvic support tissue that manifests as the descent of the pelvic organs, significantly impacting patient quality of life. Transvaginal mesh (TVM) is an effective treatment (Grade A). However, postoperative pain in the groin and medial thigh is very common. Although the use of mesh for transvaginal POP repair has been prohibited or the indications for such use have been extensively limited in many places, it is still an alternative in some countries. Therefore, the safety of the use of mesh still needs to be discussed. The current research on postoperative pain has mainly focused on management. The pathophysiology is unclear. METHODS In this study, anterior TVM surgery was performed on ten frozen cadavers. The obturator area was carefully dissected. We explored the relative position of the polypropylene mesh to the internal segment of the obturator nerve in the obturator canal. RESULTS Four out of 20 obturator explorations were insufficient to allow conclusions to be drawn. We observed a small branch of the obturator nerve, which is a new anatomical finding that we named the obturator externus muscle branch. This structure terminated in the external obturator muscle in 6 out of the 16 successfully dissected obturator areas. The mean distance between the superficial mesh arm and this nerve branch was 7.5 mm. The mean distance between the deep mesh arm and the closest nerve branch was 5.5 mm. CONCLUSION The path of the obturator externus muscle branch of the obturator nerve ran close to the mesh arm. It may provide a clinical anatomical basis explaining the observed postoperative pain.
Collapse
Affiliation(s)
- Lin Zhang
- Peking Union Medical College, Chinese Academy of Medical Sciences, Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, No. 9 Dongdan Santiao, Beijing, 100730, Dongcheng District, China
| | - Zichen Zhao
- Peking Union Medical College, Chinese Academy of Medical Sciences, Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, No. 9 Dongdan Santiao, Beijing, 100730, Dongcheng District, China
| | - Juan Chen
- Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, National Clinical Research Center for Obstetrics & Gynecologic Diseases, No. 1 Shuaifuyuan, Beijing, 100010, Dongcheng District, China
| | - Yidi Ma
- Peking Union Medical College, Chinese Academy of Medical Sciences, Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, No. 9 Dongdan Santiao, Beijing, 100730, Dongcheng District, China
| | - Guorui Zhang
- Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, National Clinical Research Center for Obstetrics & Gynecologic Diseases, No. 1 Shuaifuyuan, Beijing, 100010, Dongcheng District, China
| | - Lan Zhu
- Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, National Clinical Research Center for Obstetrics & Gynecologic Diseases, No. 1 Shuaifuyuan, Beijing, 100010, Dongcheng District, China.
| |
Collapse
|
5
|
Improvement in dyspareunia after vaginal mesh removal measured by a validated questionnaire. Int Urogynecol J 2021; 32:2937-2946. [PMID: 34351464 DOI: 10.1007/s00192-021-04923-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 06/12/2021] [Indexed: 12/14/2022]
Abstract
INTRODUCTION AND HYPOTHESIS The objective was to examine the effect of the surgical removal of vaginally placed prolapse and incontinence mesh on sexual function. We hypothesize that patients with painful complications of mesh will experience improvement in dyspareunia and sexual function after mesh removal. METHODS The eligible cohort consisted of 133 women who presented with a new onset of pain attributed to mesh-augmented incontinence or prolapse surgery and who elected to undergo mesh removal between 1 August 2012 and 1 July 2013. Sexual function symptoms were assessed before and after mesh removal surgery using the Pelvic Organ Prolapse and Urinary Incontinence Sexual Function Questionnaire short form (PISQ-12). Multivariate analysis was performed to identify predictors of improvement in dyspareunia. RESULTS Ninety-four patients undergoing mesh removal completed a pre-operative questionnaire, 63 of whom also completed a post-operative questionnaire. After mesh removal, there was a nearly 50% reduction in the proportion of women reporting always experiencing post-operative pain with intercourse among those experiencing pre-operative pain. There was a statistically significant quantitative improvement in pain with intercourse after mesh removal based on mean change score of PISQ-12 question 5 "How often do you experience pain with intercourse?". In multivariate analysis, only history of vaginal delivery was associated with symptom improvement. CONCLUSION Removal of transvaginal prolapse mesh is associated with improvement in self-reported dyspareunia based on a standardized question on a validated instrument in a small cohort of women. Although larger studies are needed to confirm the relationship between mesh-augmented surgeries and post-procedural dyspareunia, these data suggest that consideration of mesh removal is a reasonable step for patients with painful intercourse attributed to mesh-augmented prolapse and incontinence surgeries.
Collapse
|
6
|
Rogowski A, Krowicka-Wasyl M, Chotkowska E, Kluz T, Wróbel A, Berent D, Mierzejewski P, Sienkiewicz-Jarosz H, Wichniak A, Wojnar M, Samochowiec J, Kilis-Pstrusinska K, Bienkowski P. Psychiatric History and Overactive Bladder Symptom Severity in Ambulatory Urogynecological Patients. J Clin Med 2021; 10:jcm10173988. [PMID: 34501436 PMCID: PMC8432447 DOI: 10.3390/jcm10173988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 08/27/2021] [Accepted: 08/31/2021] [Indexed: 12/05/2022] Open
Abstract
Introduction and hypothesis: A link between psychiatric comorbidities and overactive bladder symptomatology has been suggested by preclinical and clinical studies. Given this, we hypothesized that a psychiatric history and current treatment with psychotropic medications could be related to the severity of overactive bladder and incontinence symptoms in patients referred to a tertiary care urogynecological center. Methods: One hundred and twenty-seven female patients diagnosed with an overactive bladder were screened for a lifetime history of psychiatric disorders and the type and number of psychotropic medications currently taken. The overall severity of overactive bladder symptoms was assessed using the Indevus Urgency Severity Scale. The severity and impact of urinary incontinence on the quality of life were quantified with the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form. Urinary incontinence was further quantified with the aid of the Urinary Distress Inventory-6. The patients were screened for stress urinary incontinence using the Stamey Incontinence Score. Results: A psychiatric history, as well as current use of at least two psychotropic medications, was associated with increased severity of overactive bladder symptoms. A history of depression and current treatment with any selective serotonin reuptake inhibitor was associated with increased severity of stress urinary incontinence symptoms. Current treatment with other psychotropic medications, including sedative-hypnotics and drugs with anticholinergic properties was not related to the severity of overactive bladder and incontinence symptoms.
Collapse
Affiliation(s)
- Artur Rogowski
- Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszynski University in Warsaw, 01-938 Warsaw, Poland
- Department of Obstetrics and Gynecology, Mother and Child Institute, 01-211 Warsaw, Poland; (M.K.-W.); (E.C.)
- Correspondence: ; Tel.: +48-604-060-090
| | - Maria Krowicka-Wasyl
- Department of Obstetrics and Gynecology, Mother and Child Institute, 01-211 Warsaw, Poland; (M.K.-W.); (E.C.)
| | - Ewa Chotkowska
- Department of Obstetrics and Gynecology, Mother and Child Institute, 01-211 Warsaw, Poland; (M.K.-W.); (E.C.)
| | - Tomasz Kluz
- Department of Gynecology and Obstetrics, Institute of Medical Sciences, Medical College of Rzeszow University, 35-310 Rzeszów, Poland;
| | - Andrzej Wróbel
- Second Department of Gynecology, Medical University of Lublin, Jaczewskiego 8, 20-954 Lublin, Poland;
| | - Dominika Berent
- Regional Psychiatric Hospital Drewnica, 05-091 Zabki, Poland;
| | - Paweł Mierzejewski
- Departments of Pharmacology, Institute of Psychiatry and Neurology, 02-957 Warsaw, Poland;
| | | | - Adam Wichniak
- Department of Psychiatry III, Institute of Psychiatry and Neurology, 02-957 Warsaw, Poland;
| | - Marcin Wojnar
- Department of Psychiatry, Medical University of Warsaw, 02-091 Warsaw, Poland; (M.W.); (P.B.)
| | - Jerzy Samochowiec
- Department of Psychiatry, Pomeranian Medical University, 70-111 Szczecin, Poland;
| | | | - Przemyslaw Bienkowski
- Department of Psychiatry, Medical University of Warsaw, 02-091 Warsaw, Poland; (M.W.); (P.B.)
| |
Collapse
|
7
|
Gamé X, Phé V. [Non-neurological overactive bladder and pelvic-perineal pathology in women]. Prog Urol 2021; 30:887-894. [PMID: 33220817 DOI: 10.1016/j.purol.2020.08.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 08/06/2020] [Accepted: 08/10/2020] [Indexed: 10/22/2022]
Abstract
INTRODUCTION The aim was to synthesize current knowledge on overactive bladder (OAB) and female pelvic-perineal diseases. METHOD A systematic literature review based on PubMed, Embase and Google Scholar was conducted in April 2020. RESULTS Women with pelvic organ prolapse very often have OAB. Prolapse surgery should be considered if the prolapse is symptomatic and never be indicated in case of overactive bladder symptoms solely. In case of symptomatic prolapse and OAB, pessary and surgical treatments are effective on both pathologies up to 71 % of the cases. OAB may occur in parallel or as part of a menopausal genitourinary syndrome. In the latter case, only local estrogen therapy is effective. OAB may occur alongside stress urinary incontinence (SUI) or be integrated into mixed urinary incontinence. The initial treatment should be based on the most troublesome symptoms. In case of SUI, the outcome of surgical treatment on OAB remains uncertain. De novo, OAB follows prolapse or SUI surgery. It requires investigations to exclude urinary tract infection, bladder outlet obstruction or erosion. The treatment is the same as OAB. CONCLUSION The clinician's challenge is to draw a balance between the OAB and a pelvic-perineal pathology in order to adapt the treatment.
Collapse
Affiliation(s)
- X Gamé
- Département d'urologie, transplantation rénale et andrologie, CHU de Rangueil, université Paul-Sabatier, Toulouse, France.
| | - V Phé
- Service d'urologie, hôpital Pitié-Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| |
Collapse
|
8
|
Poutakidis G, Marsk A, Altman D, Falconer C, Morcos E. Ultrasound evaluation of anterior transvaginal mesh for pelvic organ prolapse: correlation to 5-year clinical outcomes. Int Urogynecol J 2021; 33:1907-1915. [PMID: 34185122 PMCID: PMC9270286 DOI: 10.1007/s00192-021-04889-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 05/26/2021] [Indexed: 01/02/2023]
Abstract
Introduction and hypothesis Vaginal prolapse mesh may effectively restore vaginal anatomy. The aim of this study was to investigate how the in vivo mesh position correlates to clinical outcomes. Methods Seventy-one women operated on using Uphold mesh for apical pelvic organ prolapse (POP-Q, C ≥ stage II) were examined 5 years after surgery by introital-perineal 2D ultrasound in a midsagittal plane at rest and Valsalva. The horizontal line and pubis symphysis were considered the reference for all measures. Ultrasound measures were statistically compared to clinical outcomes: POP-Q, Pelvic Floor Distress Inventory (PFDI-20) and subscales [Pelvic Organ Distress Inventory (PODI-6), and Urinary Distress Inventory (UDI-6)] and the VAS scale for pain. Results Original mesh length was preserved by 86% and correlated to improved pain as estimated by VAS scale (r 0.321). Valsalva was associated with a lowering of the superior and inferior mesh margins by 7.3 and 6.1 mm, respectively (p < 0.001) but a reduction of total mesh length by only 1 mm (30.2 ± 5.2 to 29.2 ± 4.7 mm, p < 0.001). Mobility of the anterior vaginal wall (bladder neck and midurethra) at Valsalva was parallel to downward movement of the mesh inferior margin (r 0.346 and 0.314) but inversely correlated to total UDI-6 (r − 0.254 and − 0.263). Mobility of the midurethra was inversely correlated to bladder emptying (PFDI-20 Question 19, r − 0.245). Conclusions Five years after surgery, preserved original length of the mesh with apical support was correlated to improved anatomical and patient-reported outcomes. Mesh support to the vaginal apex was associated with improved bladder emptying and total urinary distress outcomes but not stress urinary incontinence.
Collapse
Affiliation(s)
- Georgios Poutakidis
- Department of Clinical Sciences, Division of Obstetrics and Gynecology, Karolinska Institutet Danderyd Hospital, SE-176 77, Stockholm, Sweden
| | - Anna Marsk
- Department of Gynecological Ultrasound, UltraGyn, Stockholm, Sweden
| | - Daniel Altman
- Department of Women's and Children's Health, Uppsala University, Uppsala, Sweden
| | - Christian Falconer
- Department of Clinical Sciences, Division of Obstetrics and Gynecology, Karolinska Institutet Danderyd Hospital, SE-176 77, Stockholm, Sweden
| | - Edward Morcos
- Department of Clinical Sciences, Division of Obstetrics and Gynecology, Karolinska Institutet Danderyd Hospital, SE-176 77, Stockholm, Sweden. .,Department of Gynecology & Obstetrics, Karolinska Institutet, Danderyd University Hospital, SE-182 88 Danderyd, Stockholm, Sweden.
| |
Collapse
|
9
|
Shek KL, Dietz HP. Ultrasound imaging of slings and meshes in urogynecology. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 57:526-538. [PMID: 33206433 DOI: 10.1002/uog.23545] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 10/30/2020] [Accepted: 11/06/2020] [Indexed: 06/11/2023]
Abstract
Imaging is used increasingly in urogynecology. One of the main applications is in the assessment of synthetic implants. Ultrasound is particularly useful for this purpose as most such implants appear highly echogenic on ultrasound but are not visible using other imaging techniques. The worldwide success of synthetic mid-urethral slings, introduced in the late 90s, led to the subsequent introduction of transvaginal mesh in 2003-2004. Widespread use of synthetic implants for both urinary incontinence and prolapse has caused a rise in implant-related complications and increasing negative publicity and litigation, with many products removed from the market. It is not surprising that there is increasing demand for the assessment and evaluation of sling and mesh implants using imaging. This review article discusses the role of translabial/transperineal ultrasound in the evaluation of synthetic implants used in the treatment of urinary incontinence and pelvic organ prolapse. The discussion focuses on those applications of the technique that are useful for surgeons dealing with patients after mesh and/or sling placement. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- K L Shek
- Liverpool Hospital, Western Sydney University, Liverpool, Australia
- Nepean Clinical School, University of Sydney, Penrith, Australia
| | - H P Dietz
- Nepean Clinical School, University of Sydney, Penrith, Australia
| |
Collapse
|
10
|
Allègre L, Callewaert G, Coudray C, Demattei C, Panel L, Carlier-Guerin C, Letouzey V, de Tayrac R, Fatton B. Prospective ultrasonographic follow-up of transvaginal lightweight meshes: a 1-year multicenter study. Int Urogynecol J 2020; 32:1505-1512. [PMID: 32803342 DOI: 10.1007/s00192-020-04483-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 07/28/2020] [Indexed: 10/23/2022]
Abstract
INTRODUCTION AND HYPOTHESIS The use of new lightweight meshes in pelvic organ prolapse (POP) surgery may reduce complications related to mesh retraction (chronic pain, dyspareunia, and mesh exposure). The aim of this study was to investigate changes in the area and position of Uphold Lite™ mesh 6 weeks and 12 months after anterior and/or apical prolapse repair. METHODS This observational prospective multicenter study included patients who had undergone transvaginal surgery for symptomatic POP-Q stage ≥ II anterior and/or apical compartment prolapse with placement of Uphold Lite mesh. The dimensions and position of the mesh were evaluated at 6 weeks and 12 months by ultrasonography. Correlations between ultrasonographic mesh characteristics and POP recurrence were analyzed. RESULTS Fifty evaluable women with an average age of 66.8 years were included. No statistically significant difference in mesh area was found between week 6 and month 12 postoperatively, either at rest (1746.92 vs. 1574.48 mm2; p = 0.15) or on Valsalva (1568.81 vs. 1542.98 mm2; p = 0.65). The ROC-AUC of the distance between the mesh and the bladder neck (M-BN) at 6 weeks for predicting cystocele recurrence at 12 months was 0.764 (95% CI 0.573-0.955) at rest and 0.724 (95% CI 0.533-0.916) on Valsalva. An M-BN distance > 12.5 mm could predict cystocele recurrence at month 12 with a sensitivity of 80% and a specificity of 69%. CONCLUSIONS Ultrasonographic measurements of the Uphold Lite™ mesh appear to remain stable between 6 weeks and 12 months postoperatively. M-BN distance correlates with cystocele recurrence. These results appear to confirm the value of ultrasound in mesh evaluation.
Collapse
Affiliation(s)
- Lucie Allègre
- Department of Obstetrics and Gynecology, Nîmes University Hospital, Nîmes, France.
| | - Geertje Callewaert
- Department of Obstetrics and Gynecology, Nîmes University Hospital, Nîmes, France
| | - Charles Coudray
- Department of Obstetrics and Gynecology, Nîmes University Hospital, Nîmes, France
| | - Christophe Demattei
- Department of BESPIM (Biostatistics, Epidemiology, Public Health, and Innovation in Methodology), Nîmes University Hospital, Nîmes, France
| | - Laure Panel
- Department of Gynecology, Clinique Beau Soleil, Montpellier, France
| | | | - Vincent Letouzey
- Department of Obstetrics and Gynecology, Nîmes University Hospital, Nîmes, France
| | - Renaud de Tayrac
- Department of Obstetrics and Gynecology, Nîmes University Hospital, Nîmes, France
| | - Brigitte Fatton
- Department of Obstetrics and Gynecology, Nîmes University Hospital, Nîmes, France
| |
Collapse
|
11
|
Duckett J, Thakar R, Shah V, Stephenson J, Balachandran A. The Use of Imaging for Synthetic Midurethral Slings. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:1497-1506. [PMID: 32125008 DOI: 10.1002/jum.15254] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 01/29/2020] [Accepted: 02/03/2020] [Indexed: 06/10/2023]
Abstract
Ultrasound and magnetic resonance imaging can be used to image midurethral slings, which have may have complications such as pain. There is considerable misunderstanding regarding the utility of the different modalities. This article aims to review the current literature to identify the benefits and limitations of each imaging modality and identify the place that each should have for patients with midurethral sling complications. A literature search was performed, and all relevant articles were identified and reviewed. Different imaging modalities are complementary, but more research is required in this area.
Collapse
Affiliation(s)
- Jonathan Duckett
- Department of Obstetrics and Gynecology, Medway Maritime Hospital, Gillingham, Kent, England
| | - Ranee Thakar
- Croydon Urogynecology and Pelvic Floor Reconstruction Unit, Croydon University Hospital, Croydon, Surrey, England
| | - Vikas Shah
- Gastrointestinal Imaging Group, Glenfield General Hospital, University Hospitals of Leicester, Leicester, England
| | - James Stephenson
- Gastrointestinal Imaging Group, Glenfield General Hospital, University Hospitals of Leicester, Leicester, England
| | - Aswini Balachandran
- Croydon Urogynecology and Pelvic Floor Reconstruction Unit, Croydon University Hospital, Croydon, Surrey, England
| |
Collapse
|
12
|
Mortier A, Cardaillac C, Perrouin-Verbe MA, Meurette G, Ploteau S, Lesveque A, Riant T, Dochez V, Thubert T. [Pelvic and perineal pain after genital prolapse: A literature review]. Prog Urol 2020; 30:571-587. [PMID: 32651103 DOI: 10.1016/j.purol.2020.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 06/05/2020] [Accepted: 06/09/2020] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Pelvic and perineal pain after genital prolapse surgery is a serious and frequent post-operative complication which diagnosis and therapeutic management can be complex. MATERIALS ET METHODS A literature review was carried out on the Pubmed database using the following words and MeSH : genital prolapse, pain, dyspareunia, genital prolapse and pain, genital prolapse and dyspareunia, genital prolapse and surgery, pain and surgery. RESULTS Among the 133 articles found, 74 were selected. Post-operative chronic pelvic pain persisting more than 3 months after surgery according to the International Association for the Study of Pain. It can be nociceptive, neuropathic or dysfunctional. Its diagnosis is mainly clinical. Its incidence is estimated between 1% and 50% and the risk factors are young age, the presence of comorbidities, history of prolapse surgery, severe prolapse, preoperative pain, invasive surgical approach, simultaneous placement of several meshes, less operator experience, increased operative time and early post-operative pain. The vaginal approach can cause a change in compliance and vaginal length as well as injury to the pudendal, sciatic and obturator nerves and in some cases lead to myofascial pelvic pain syndrome, whereas the laparoscopic approach can lead to parietal nerve damage. Therapeutic management is multidisciplinary and complex. CONCLUSION Pelvic pain after genital prolapse surgery is still obscure to this day.
Collapse
Affiliation(s)
- A Mortier
- Service de gynécologie, CHU de Nantes, 38, boulevard Jean-Monnet, 44000 Nantes, France
| | - C Cardaillac
- Service de gynécologie, CHU de Nantes, 38, boulevard Jean-Monnet, 44000 Nantes, France
| | - M-A Perrouin-Verbe
- Service d'urologie, CHU de Nantes, 1, place Alexis-Ricordeau, 44000 Nantes, France; GREEN, groupe de recherche clinique en neuro-urologie, GRCUPMC01, 75020 Paris, France
| | - G Meurette
- Service de chirurgie viscérale, CHU de Nantes, 1, place Alexis-Ricordeau, 44000 Nantes, France; Centre fédératif de pelvi-périnéologie, Nantes, France
| | - S Ploteau
- Service de gynécologie, CHU de Nantes, 38, boulevard Jean-Monnet, 44000 Nantes, France; Centre fédératif de pelvi-périnéologie, Nantes, France
| | - A Lesveque
- Service d'urologie, CHU de Nantes, 1, place Alexis-Ricordeau, 44000 Nantes, France; Centre fédératif de pelvi-périnéologie, Nantes, France
| | - T Riant
- Centre fédératif de pelvi-périnéologie, Nantes, France
| | - V Dochez
- Service de gynécologie, CHU de Nantes, 38, boulevard Jean-Monnet, 44000 Nantes, France; CIC, Centre d'investigation clinique, CHU de Nantes, 5, allée de l'Île-Gloriette, 44093 Nantes cedex 01, France
| | - T Thubert
- Service de gynécologie, CHU de Nantes, 38, boulevard Jean-Monnet, 44000 Nantes, France; CIC, Centre d'investigation clinique, CHU de Nantes, 5, allée de l'Île-Gloriette, 44093 Nantes cedex 01, France; GREEN, groupe de recherche clinique en neuro-urologie, GRCUPMC01, 75020 Paris, France; Centre fédératif de pelvi-périnéologie, Nantes, France.
| |
Collapse
|
13
|
IJsselmuiden MN, Oudheusden AMJ, Veen J, Pol G, Vollebregt A, Radder CM, Housmans S, Kuijk SMJ, Deprest J, Bongers MY, Eijndhoven HWF. Hysteropexy in the treatment of uterine prolapse stage 2 or higher: laparoscopic sacrohysteropexy versus sacrospinous hysteropexy—a multicentre randomised controlled trial (LAVA trial). BJOG 2020; 127:1284-1293. [DOI: 10.1111/1471-0528.16242] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/25/2020] [Indexed: 02/05/2023]
Affiliation(s)
- MN IJsselmuiden
- Department of Obstetrics and GynaecologyIsala Zwolle The Netherlands
- Department of Obstetrics and GynaecologyGROW School for Oncology and Developmental BiologyMaastricht University Medical Centre Maastricht The Netherlands
| | - AMJ Oudheusden
- Department of Obstetrics and GynaecologyGROW School for Oncology and Developmental BiologyMaastricht University Medical Centre Maastricht The Netherlands
| | - J Veen
- Department of Obstetrics and GynaecologyMáxima Medical Centre Veldhoven The Netherlands
| | - G Pol
- Department of Obstetrics and GynaecologyGelre Ziekenhuizen Apeldoorn The Netherlands
| | - A Vollebregt
- Department of Obstetrics and GynaecologySpaarne Gasthuis Hoofddorp The Netherlands
| | - CM Radder
- Department of Obstetrics and GynaecologyOLVG Amsterdam The Netherlands
| | - S Housmans
- Department of Obstetrics and GynaecologyUniversity Hospitals Leuven Leuven Belgium
| | - SMJ Kuijk
- Department of Obstetrics and GynaecologyGROW School for Oncology and Developmental BiologyMaastricht University Medical Centre Maastricht The Netherlands
| | - J Deprest
- Department of Obstetrics and GynaecologyUniversity Hospitals Leuven Leuven Belgium
| | - MY Bongers
- Department of Obstetrics and GynaecologyGROW School for Oncology and Developmental BiologyMaastricht University Medical Centre Maastricht The Netherlands
- Department of Obstetrics and GynaecologyMáxima Medical Centre Veldhoven The Netherlands
| | - HWF Eijndhoven
- Department of Obstetrics and GynaecologyIsala Zwolle The Netherlands
| |
Collapse
|
14
|
Mancuso E, Downey C, Doxford‐Hook E, Bryant MG, Culmer P. The use of polymeric meshes for pelvic organ prolapse: Current concepts, challenges, and future perspectives. J Biomed Mater Res B Appl Biomater 2019; 108:771-789. [DOI: 10.1002/jbm.b.34432] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 05/07/2019] [Accepted: 05/31/2019] [Indexed: 12/18/2022]
Affiliation(s)
- Elena Mancuso
- Ulster UniversityNanotechnology and Integrated Bio‐Engineering Centre (NIBEC) Jordanstown campus ‐ Newtownabbey UK
| | - Candice Downey
- Leeds Institute of Medical Research at St James'sUniversity of Leeds Leeds UK
| | | | | | - Peter Culmer
- School of Mechanical EngineeringUniversity of Leeds Leeds UK
| |
Collapse
|
15
|
Taithongchai A, Sultan AH, Wieczorek PA, Thakar R. Clinical application of 2D and 3D pelvic floor ultrasound of mid-urethral slings and vaginal wall mesh. Int Urogynecol J 2019; 30:1401-1411. [DOI: 10.1007/s00192-019-03973-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 04/22/2019] [Indexed: 12/22/2022]
|
16
|
Abstract
PURPOSE OF REVIEW Since 2011, there has been increasing attention paid to the use of synthetic grafts (mesh) in pelvic reconstructive surgery. Although synthetic grafts are considered permanent implants to improve outcomes, the use of this material has created inadvertent complications such as erosion, chronic pain, and dyspareunia. Patient evaluation is complex and surgical techniques carry risks not yet completely understood. This review summarizes current opinions in synthetic graft excision for the treatment of mesh-related complications. RECENT FINDINGS Recent studies reveal excisions are being increasingly performed and graft placement is decreasing. Patients of lower-volume surgeons have a higher risk of complication and need for excisional procedures. Pain is becoming the most common indication for vaginal mesh excision and that pain is mostly elicited with palpation of the mesh arms. Explantation is technically challenging and carries significant risks. SUMMARY Vaginal synthetic graft complications are increasingly being managed by surgical excision. Careful evaluation of patient symptoms and objective findings should help guide management. Surgeons considering operative management should counsel patients regarding the risks of excision including but not limited to hemorrhage, nerve damage, muscular injury, and recurrent symptoms.
Collapse
|
17
|
Natalia S, Menahem N, Haim K, Dmitri P. The "Pelvic Harness": a skeletonized mesh implant for safe pelvic floor reconstruction. Int Braz J Urol 2017; 42:507-13. [PMID: 27286114 PMCID: PMC4920568 DOI: 10.1590/s1677-5538.ibju.2015.0177] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2015] [Accepted: 05/06/2015] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES To evaluate the feasibility, safety and surgical results of skeletonized mesh implants to form a pelvic harness for pelvic floor reconstruction surgery. STUDY DESIGN Patients with advanced pelvic floor prolapse were enrolled to this study. Study model was a kit mesh, reduced to 75% of the original surface area by cutting out mesh material from the central mesh body. Patients were evaluated at the end of the 1st and 6th post-operative months and interviewed at the study conclusion. RESULTS Ninety-five women with advanced pelvic floor prolapse had this implant. Mean follow-up duration was 9 months (6-12 months). The POP-Q point's measurements showed marked and statistically significant improvements. Bladder over-activity symptoms, fecal incontinence, pelvic pain and constipation rates were all reduced as well. No adverse effects related to the dissection or mesh implantation were marked. The first and sixth post-operative month follow-up records as well as the study conclusion interview findings were satisfactory in terms of subjective and objective cure and adverse effects occurrence. CONCLUSION This study data proposes that skeletonizing meshes might be safely and successfully implanted for potentially improved pelvic floor reconstruction.
Collapse
Affiliation(s)
| | - Neuman Menahem
- Urogynecology Unit, Departaments of Obstetrics and Gynecology, Galilee Hospital, Nahariya.,Bar-Ilan University, Faculty of Medicine, Safed, Israel
| | - Krissi Haim
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva, and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Pushkar Dmitri
- Department of Urology, Moscow Medical Stomatological University, Russia
| |
Collapse
|
18
|
Ultrasound imaging in urogynecology - state of the art 2016. MENOPAUSE REVIEW 2016; 15:123-132. [PMID: 27980522 PMCID: PMC5137478 DOI: 10.5114/pm.2016.63060] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2016] [Accepted: 09/29/2016] [Indexed: 01/03/2023]
Abstract
The role of ultrasound imaging in urogynecology is not clearly defined. Despite significant developments in visualization techniques and interpretation of images, pelvic ultrasound is still more a tool for research than for clinical practice. Structures of the lower genitourinary tract and pelvic floor can be visualized from different approaches: transperineal, introital, transvaginal, abdominal or endoanal. According to contemporary guidelines and recommendations, the role of ultrasound in urogynecology is limited to the measurement of post-void residue. However, in many instances, including planning and audit of surgical procedures, management of recurrences or complications, ultrasound may be proposed as the initial examination of choice. Ultrasound may be used for assessment of bladder neck mobility before anti-incontinence procedures. On rare occasions it is helpful in recognition of pathologies mimicking vaginal prolapse such as vaginal cyst, urethral diverticula or rectal intussusception. In patients subjected to suburethral slings, causes of surgery failure or postsurgical voiding dysfunctions can be revealed by imaging. Many reports link the location of a tape close to the bladder neck to unfavorable outcomes of sling surgery. Some postoperative complications, such as urinary retention, mesh malposition, hematoma, or urinary tract injury, can be diagnosed by ultrasound. On the other hand, the clinical value of some applications of ultrasound in urogynecology, for example measurement of the bladder wall thickness as a marker of detrusor overactivity, has not been proved.
Collapse
|
19
|
Barone WR, Moalli PA, Abramowitch SD. Textile properties of synthetic prolapse mesh in response to uniaxial loading. Am J Obstet Gynecol 2016; 215:326.e1-9. [PMID: 27001219 PMCID: PMC5161096 DOI: 10.1016/j.ajog.2016.03.023] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Revised: 02/25/2016] [Accepted: 03/11/2016] [Indexed: 02/03/2023]
Abstract
BACKGROUND Although synthetic mesh is associated with superior anatomic outcomes for the repair of pelvic organ prolapse, the benefits of mesh have been questioned because of the relatively high complication rates. To date, the mechanisms that result in such complications are poorly understood, yet the textile characteristics of mesh products are believed to play an important role. Interestingly, the pore diameter of synthetic mesh has been shown to impact the host response after hernia repair greatly, and such findings have served as design criteria for prolapse meshes, with larger pores viewed as more favorable. Although pore size and porosity are well-characterized before implantation, the changes in these textile properties after implantation are unclear; the application of mechanical forces has the potential to greatly alter pore geometries in vivo. Understanding the impact of mechanical loading on the textile properties of mesh is essential for the development of more effective devices for prolapse repair. OBJECTIVE The objective of this study was to determine the effect of tensile loading and pore orientation on mesh porosity and pore dimensions. STUDY DESIGN In this study, the porosity and pore diameter of 4 currently available prolapse meshes were examined in response to uniaxial tensile loads of 0.1, 5, and 10 N while mimicking clinical loading conditions. The textile properties were compared with those observed for the unloaded mesh. Meshes included Gynemesh PS (Ethicon, Somerville, NJ), UltraPro (Artisyn; Ethicon), Restorelle (Coloplast, Minneapolis, MN), and Alyte Y-mesh (Bard, Covington, GA). In addition to the various pore geometries, 3 orientations of Restorelle (0-, 5-, 45-degree offset) and 2 orientations of UltraPro (0-, 90-degree offset) were examined. RESULTS In response to uniaxial loading, both porosity and pore diameter dramatically decreased for most mesh products. The application of 5 N led to reductions in porosity for nearly all groups, with values decreasing by as much as 87% (P < .05). On loading to 10 N of force, nearly all mesh products that were tested were found to have porosities that approached 0% and 0 pores with diameters >1 mm. CONCLUSION In this study, it was shown that the pore size of current prolapse meshes dramatically decreases in response to mechanical loading. These findings suggest that prolapse meshes, which are more likely to experience tensile forces in vivo relative to hernia repair meshes, have pores that are unfavorable for tissue integration after surgical tensioning and/or loading in urogynecologic surgeries. Such decreases in pore geometry support the hypothesis that regional increases in the concentration of mesh leads to an enhanced local foreign body response. Although pore deformation in transvaginal meshes requires further characterization, the findings presented here provide a mechanical understanding that can be used to recognize potential areas of concern for complex mesh geometries. Understanding mesh mechanics in response to surgical and in vivo loading conditions may provide improved design criteria for mesh and a refinement of surgical techniques, ultimately leading to better patient outcomes.
Collapse
Affiliation(s)
- William R Barone
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA
| | - Pamela A Moalli
- Magee-Womens Research Institute, Magee-Womens Hospital, University of Pittsburgh, Pittsburgh, PA
| | - Steven D Abramowitch
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Magee-Womens Research Institute, Magee-Womens Hospital, University of Pittsburgh, Pittsburgh, PA.
| |
Collapse
|
20
|
Vaginal Mesh in Pelvic Reconstructive Surgery: Controversies, Current Use, and Complications. Clin Obstet Gynecol 2016; 58:740-53. [PMID: 26512439 DOI: 10.1097/grf.0000000000000148] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
In 2001, the Food and Drug Administration approved the first surgical mesh product specifically designed for the surgical repair of pelvic organ prolapse and between 2004 and 2008, the use of vaginal mesh in gynecologic surgery was at its peak. Unfortunately, the rise in transvaginal mesh use was accompanied by a surge of adverse events and mesh-related complications. As a result, the Food and Drug Administration put forth several efforts to regulate the manufacturing of vaginal mesh products. These notifications have been supported by several gynecologic societies, and recommendations now exist not only on the placement of mesh and patient selection, but also on the evaluation and management of mesh-related complications. In addition, data on outcomes following management of these complications are now emerging.
Collapse
|
21
|
Nolfi AL, Brown BN, Liang R, Palcsey SL, Bonidie MJ, Abramowitch SD, Moalli PA. Host response to synthetic mesh in women with mesh complications. Am J Obstet Gynecol 2016; 215:206.e1-8. [PMID: 27094962 PMCID: PMC5201165 DOI: 10.1016/j.ajog.2016.04.008] [Citation(s) in RCA: 91] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 03/31/2016] [Accepted: 04/08/2016] [Indexed: 01/11/2023]
Abstract
BACKGROUND Despite good anatomic and functional outcomes, urogynecologic polypropylene meshes that are used to treat pelvic organ prolapse and stress urinary incontinence are associated with significant complications, most commonly mesh exposure and pain. Few studies have been performed that specifically focus on the host response to urogynecologic meshes. The macrophage has long been known to be the key cell type that mediates the foreign body response. Conceptually, macrophages that respond to a foreign body can be dichotomized broadly into M1 proinflammatory and M2 proremodeling subtypes. A prolonged M1 response is thought to result in chronic inflammation and the formation of foreign body giant cells with potential for ongoing tissue damage and destruction. Although a limited M2 predominant response is favorable for tissue integration and ingrowth, excessive M2 activity can lead to accelerated fibrillar matrix deposition and result in fibrosis and encapsulation of the mesh. OBJECTIVE The purpose of this study was to define and compare the macrophage response in patients who undergo mesh excision surgery for the indication of pain vs a mesh exposure. STUDY DESIGN Patients who were scheduled to undergo a surgical excision of mesh for pain or exposure at Magee-Womens Hospital were offered enrollment. Twenty-seven mesh-vagina complexes that were removed for the primary complaint of a mesh exposure (n = 15) vs pain in the absence of an exposure (n = 12) were compared with 30 full-thickness vaginal biopsy specimens from women who underwent benign gynecologic surgery without mesh. Macrophage M1 proinflammatory vs M2 proremodeling phenotypes were examined via immunofluorescent labeling for cell surface markers CD86 (M1) vs CD206 (M2) and M1 vs M2 cytokines via enzyme-linked immunosorbent assay. The amount of matrix metalloproteinase-2 (MMP-2) and matrix metalloproteinase-9 (MMP-9) proteolytic enzymes were quantified by zymography and substrate degradation assays, as an indication of tissue matrix degradation. Statistics were performed with the use of 1-way analysis of variance with appropriate post hoc tests, t-tests, and Fisher's Exact test. RESULTS Twenty-seven mesh-vaginal tissue complexes were excised from 27 different women with mesh complications: 15 incontinence mid urethral slings and 12 prolapse meshes. On histologic examination, macrophages surrounded each mesh fiber in both groups, with predominance of the M1 subtype. M1 and M2 cytokines/chemokines, MMP-9 (pro- and active), and MMP-2 (active) were increased significantly in mesh-vagina explants, as compared with vagina without mesh. Mesh explants that were removed for exposure had 88.4% higher pro-MMP-9 (P = .035) than those removed for pain. A positive correlation was observed between the profibrotic cytokine interleukin-10 and the percentage of M2 cells (r = 0.697; P = .037) in the pain group. CONCLUSION In women with complications, mesh induces a proinflammatory response that persists years after implantation. The increase in MMP-9 in mesh explants that were removed for exposure indicates degradation; the positive association between interleukin-10 and M2 macrophages in mesh explants that are removed for pain is consistent with fibrosis.
Collapse
Affiliation(s)
- Alexis L Nolfi
- Magee-Womens Research Institute, University of Pittsburgh, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Bryan N Brown
- Magee-Womens Research Institute, University of Pittsburgh, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Rui Liang
- Magee-Womens Research Institute, University of Pittsburgh, Pittsburgh, PA; Department of Obstetrics, Gynecology, and Reproductive Sciences, School of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Stacy L Palcsey
- Magee-Womens Research Institute, University of Pittsburgh, Pittsburgh, PA
| | - Michael J Bonidie
- Department of Obstetrics, Gynecology, and Reproductive Sciences, School of Medicine, University of Pittsburgh, Pittsburgh, PA
| | | | - Pamela A Moalli
- Magee-Womens Research Institute, University of Pittsburgh, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Department of Obstetrics, Gynecology, and Reproductive Sciences, School of Medicine, University of Pittsburgh, Pittsburgh, PA.
| |
Collapse
|
22
|
Assessing the use of the IUGA/ICS classification system for prosthesis/graft complications in publications from 2011 to 2015. Int Urogynecol J 2016; 27:1905-1911. [PMID: 27250834 DOI: 10.1007/s00192-016-3056-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 05/17/2016] [Indexed: 10/21/2022]
Abstract
INTRODUCTION AND HYPOTHESIS Complications of pelvic organ prolapse and urinary incontinence surgery have gained increasing attention from both lay media and medical societies. The International Urogynecological Association and International Continence Society proposed the category-time-site system to classify complications in 2011. Our objective is to assess the usage of the category-time-site system in the literature. METHODS We conducted a systematic review and identified records using PubMed search terms "mesh" and "prolapse or incontinence" and "complication or excision" (February 2011 to December 2015) to select publications following the introduction of category-time-site system. Relevant publications were included and reviewed for study design, initial procedure, number of patients assigned codes, number of unique codes applied, purpose of assigning codes, and duration of clinical follow-up. RESULTS Of 167 eligible records, 23 (14 %) used the system, 137 (82 %) used no system, and 7 (4 %) used another system. They included three study designs: randomized control trials, case reports, and case series. Given the very limited amount of data, no statistical tests were performed, but trends were noted. CONCLUSIONS Fourteen percent of the reports in the literature describing complications related to prosthesis/graft use in pelvic surgery utilize the category-time-site system. The system's limited and inconsistent use hinders the ability to draw conclusions useful for clinical practice. Effort should be directed toward improving appropriate usage or revising the system to increase its exposure in related publications. An improved system will better prepare pelvic surgeons for assessing future generations of prostheses/grafts.
Collapse
|
23
|
Unger CA. An Update on the Use of Mesh in Pelvic Reconstructive Surgery. CURRENT OBSTETRICS AND GYNECOLOGY REPORTS 2016. [DOI: 10.1007/s13669-016-0145-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
24
|
Rogowski A, Bienkowski P, Tarwacki D, Szafarowska M, Samochowiec J, Sienkiewicz-Jarosz H, Jerzak M, Baranowski W. Retrospective comparison between the Prolift and Elevate anterior vaginal mesh procedures: 18-month clinical outcome. Int Urogynecol J 2015; 26:1815-20. [DOI: 10.1007/s00192-015-2772-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Accepted: 06/19/2015] [Indexed: 01/19/2023]
|
25
|
Perioperative outcomes and prospective patient reported outcome measures for transvaginal mesh surgery. Arch Gynecol Obstet 2015; 292:875-82. [PMID: 25903519 DOI: 10.1007/s00404-015-3724-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Accepted: 04/13/2015] [Indexed: 01/26/2023]
Abstract
PURPOSE To determine perioperative morbidity associated with the transvaginal mesh and analyse patient reported outcome measures following transvaginal mesh surgery via a prospective cohort study. METHODS A retrospective review and a prospective cohort study of vaginal symptoms via a validated questionnaire (Ethically approved). 159 consecutive women who underwent transvaginal polypropylene mesh repair for pelvic organ prolapse from January 2009 to January 2012 by a single experienced urogynaecologist were identified using theatre records and formed the study population. The type and frequency of intraoperative and postoperative complications, mesh exposure rates and need for further surgery were recorded. 59/159 patients consented to complete both preoperative and postoperative assessment of vaginal symptoms using the validated International Consultation on Incontinence Modular Questionnaire-Vaginal symptoms (ICIQ-VS). 51/59 patients completed both questionnaires. RESULTS The average age of the study population was 63 years (range 39-87 years). The mean BMI was 28.5 (range 20-40). 86 % (n = 138/159) had a previous hysterectomy. 98 % (n = 156/159) of patients did not have any intraoperative complications. 0.62 % (n = 1/159) had a bladder injury. Mesh exposure was noted in 4 % of the entire group (n = 6/135) at follow-up with overall reoperation rate of 9 % (n = 13/135). Statistically significant improvement in most arms of the ICIQ-VS questionnaire was noted in the cohort of 51 patients at follow-up. CONCLUSION Our data revealed a very low intraoperative complication rate with a mesh exposure rate of 4 %. The prospective study showed a statistically significant improvement in vaginal symptoms.
Collapse
|
26
|
Abstract
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Surgical mesh has been used since the 1950s to repair abdominal hernias. In the 1970s, gynecologists began using surgical mesh products to indicate the repair of pelvic organ prolapse (POP), and in the 1990s, gynecologists began using surgical mesh for POP. Then the U.S. Food and Drug Administration (FDA) approved the first surgical mesh product specifically for use in POP. Surgical mesh materials can be divided into several categories. Most surgical mesh devices cleared for POP procedures are composed of non-absorbable synthetic polypropylene. Mesh can be placed in the anterior vaginal wall to aid in the correction of cystocele (anterior repair), in the posterior vaginal wall to aid in correction of rectocele (posterior repair), or attached to the top of the vagina to correct uterine prolapse or vaginal apical prolapse (apical repair). Over the past decades, surgical mesh products for transvaginal POP repair became incorporated into "kits" that included tools to aid in the delivery and insertion of the mesh. Surgical mesh kits continue to evolve, adding new insertion tools, tissue fixation anchors, surgical techniques, and ab- sorbable and biological materials. This procedure has been performed popularly. It was also performed increased in China. But this new technique met some trouble recently and let shake in urogynecology.
Collapse
|
27
|
Association between metabolic syndrome and pelvic organ prolapse severity. Int Urogynecol J 2014; 26:563-8. [PMID: 25047898 PMCID: PMC4371825 DOI: 10.1007/s00192-014-2468-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2014] [Accepted: 06/22/2014] [Indexed: 01/24/2023]
Abstract
Introduction and hypothesis As in the case of cardiovascular and metabolic diseases, the prevalence of pelvic organ prolapse (POP) has been rising with the increasing proportion of elderly women in the population. The purpose of the present cross-sectional study was to evaluate the components of metabolic syndrome (MS) in urogynecological patients with a variable POP severity. Methods The MS risk factors (elevated waist circumference, elevated triglycerides, decreased high-density lipoprotein cholesterol, elevated blood pressure, hyperglycemia) were assessed in 100 women who were referred to our urogynecological center with pelvic floor disorders (PFD). POP was evaluated with the Pelvic Organ Prolapse Quantification system (POP-Q). Results The χ2 test revealed that the diagnosis of MS and the presence of elevated triglycerides increased with the overall POP-Q stage. The other MS risk factors were not significantly associated with the overall POP-Q stage. MS and elevated triglycerides were predictors of the POP-Q stage ≥III [odds ratio (OR) 3.5, 95 % confidence interval (CI) 1.5–8.2 for MS and OR 3.4, 95 % CI 1.4–8.2 for elevated triglycerides, p < 0.01]. Conclusions The diagnosis of MS and the presence of elevated triglycerides may be associated with the severity of POP in urogynecological patients. Longitudinal studies are required to assess whether the MS risk factors might predict the progression of POP and whether elimination of the risk factors might improve the prognosis in POP patients.
Collapse
|
28
|
Abstract
The popularity of imaging in pelvic floor medicine continues to increase. Among the various modalities, ultrasound is superior as it is cheap, safe, easily accesible and simple, resulting in high patient compliance. It is the only technique that allows imaging of modern wide-weave polypropylene sling or mesh implants, and imaging of such implants is commonly required due to the popularity of surgical techniques that involve the placement of slings and meshes. This review article will discuss the role of translabial ultrasound in the evaluation of synthetic implants used in the treatment of urinary incontinence and pelvic organ prolapse.
Collapse
Affiliation(s)
- Ka Lai Shek
- Liverpool Hospital University of Western Sydney Liverpool New South Wales Australia
| | - Hans Peter Dietz
- Nepean Clinical School University of Sydney Sydney New South Wales Australia
| |
Collapse
|
29
|
Hou JC, Alhalabi F, Lemack GE, Zimmern PE. Outcome of transvaginal mesh and tape removed for pain only. J Urol 2014; 192:856-60. [PMID: 24735934 DOI: 10.1016/j.juro.2014.04.006] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/07/2014] [Indexed: 01/19/2023]
Abstract
PURPOSE Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. MATERIALS AND METHODS After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. RESULTS From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. CONCLUSIONS When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup.
Collapse
Affiliation(s)
- Jack C Hou
- Department of Urology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas
| | - Feras Alhalabi
- Department of Urology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas
| | - Gary E Lemack
- Department of Urology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas
| | - Philippe E Zimmern
- Department of Urology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas.
| |
Collapse
|
30
|
Abstract
OBJECTIVE Complications from transvaginal mesh placed for prolapse often require operative management. The aim of this study is to describe the outcomes of vaginal mesh removal. METHODS A retrospective review of all patients having surgery by the urogynecology group in the department of obstetrics and gynecology at our institution for a complication of transvaginal mesh placed for prolapse was performed. Demographics, presenting symptoms, surgical procedures, and postoperative symptoms were abstracted. Comparative statistics were performed using the χ or Fisher's exact test with significance at P<.05. RESULTS Between January 2008 and April 2012, 90 patients had surgery for complications related to vaginal mesh and 84 had follow-up data. The most common presenting signs and symptoms were: mesh exposure, 62% (n=56); pain, 64% (n=58); and dyspareunia, 48% (n=43). During operative management, mesh erosion was encountered unexpectedly in a second area of the vagina in 5% (n=4), in the bladder in 1% (n=1), and in the bowel in 2% (n=2). After vaginal mesh removal, 51% (n=43) had resolution of all presenting symptoms. Mesh exposure was treated successfully in 95% of patients, whereas pain was only successfully treated in 51% of patients. CONCLUSION Removal of vaginal mesh is helpful in relieving symptoms of presentation. Patients can be reassured that exposed mesh can almost always be successfully managed surgically, but pain and dyspareunia are only resolved completely in half of patients. LEVEL OF EVIDENCE III.
Collapse
|
31
|
Nohuz E, Alaboud M, Darcha C, Alloui A, Aublet-Cuvelier B, Jacquetin B. Effectiveness of Hyalobarrier and Seprafilm to prevent polypropylene mesh shrinkage: a macroscopic and histological experimental study. Int Urogynecol J 2014; 25:1081-7. [PMID: 24599179 DOI: 10.1007/s00192-014-2357-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Accepted: 02/07/2014] [Indexed: 02/03/2023]
Abstract
INTRODUCTION AND HYPOTHESIS Polypropylene (PP) mesh shrinkage represents a serious complication, as a significant cause of pain and recurrence of pelvic organ prolapse or ventral hernias, frequently requiring several surgical interventions. The retraction seems to be caused by the host, in response to the implantation, through the occurrence of periprosthetic adhesions and fibrosis. We hypothesized that avoiding the postoperative adhesions can prevent PP mesh shrinkage. METHODS Sixty rats were randomly assigned to three groups. A standardized hernia defect was induced on the abdominal wall, which was repaired using an extraperitoneal PP mesh alone (group 1), with application of a hyaluronate carboxymethylcellulose-based bioresorbable membrane (Seprafilm, group 2), or an auto-cross-linked polysaccharide hyaluronan-based solution (Hyalobarrier gel, group 3). Eight weeks after the procedure, a repeat laparotomy was performed. After scoring the adhesion and measuring the mesh surface, a microscopic study of the prosthesis-host tissue interfaces was performed. RESULTS Group 1 displayed a median shrinkage of 29% of the mesh. The Seprafilm group (p = 0.0238) and Hyalobarrier gel group (p = 0.0072) displayed a significantly smaller reduction of 19.12 and 17 %, respectively. Control group 1 displayed a significantly greater adhesion score (30.40) than the Seprafilm (11.67, p = 0.0028) and Hyalobarrier gel groups (11.19, p = 0.0013). The fibrosis was reduced in the Hyalobarrier gel group only. CONCLUSION This experimental study revealed that Hyalobarrier gel and Seprafilm can prevent PP mesh shrinkage and postoperative adhesions. They might be integrated in a mesh size-saving strategy, which should preserve the quality and durability of the surgical repair and limit the postoperative pain.
Collapse
Affiliation(s)
- Erdogan Nohuz
- Department of Obstetrics and Gynecology, General Hospital of Thiers, Route du Fau, 63300, Thiers, France,
| | | | | | | | | | | |
Collapse
|
32
|
Mesh retraction correlates with vaginal pain and overactive bladder symptoms after anterior vaginal mesh repair: reply to comment by Jacquetin. Int Urogynecol J 2014; 25:705. [PMID: 24566494 PMCID: PMC3997828 DOI: 10.1007/s00192-014-2334-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
33
|
Jacquetin B. Mesh retraction correlates with vaginal pain and overactive bladder symptoms after anterior vaginal mesh repair: comment on Rogowski et al. Int Urogynecol J 2014; 25:703-4. [PMID: 24566495 DOI: 10.1007/s00192-014-2335-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- B Jacquetin
- Urogynecology Unit, Department of Gynecology-Obstetrics & Human Reproduction, Estaing University Hospital, 1 place Lucie Aubrac, 63003, Clermont-Ferrand cedex 1, France,
| |
Collapse
|