1
|
Xia D, Pan G, Liu Y, Liu H, Zhao B, Wu J, Tang T, Lu G, Wang R. Unlocking the future potential of SWATH-MS: Advancing non-target screening workflow for the qualitative and quantitative analysis of emerging contaminants. WATER RESEARCH 2025; 277:123323. [PMID: 40020354 DOI: 10.1016/j.watres.2025.123323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2024] [Revised: 02/15/2025] [Accepted: 02/17/2025] [Indexed: 03/03/2025]
Abstract
SWATH-MS offers a robust data-independent acquisition method for complex proteomics and metabolomics. This study presents a detailed non-target screening workflow utilizing SWATH-MS to detect and analyze emerging contaminants (ECs) in aquatic environments. Our workflow, covering peak picking, alignment, prioritization, structure identification, and quantification, effectively identified all qualifying peaks from 298 standard compounds with different concentrations, discarding any that did not meet the criteria. In extracts of real water samples spiked at 100 and 10 ng/mL, our workflow prioritized 2083 and 1328 features, respectively. Following structure identification, these features were assigned confidence levels ranging from 1 to 5. Of these, 215 and 92 spiked standards achieved level 1. The remaining standards were not recognized as level 1 due to low intensities or poor peak shapes that failed to meet certain criteria. Additionally, using fragment ion peak areas for quantification significantly improved the linearity of standard curves, enhancing R2 values for ∼63 % of the standards. Incorporating fragment ion data improved quantification accuracy, increasing compounds within the 80 %-120 % range from 78 % to 90 % at 100 ng/mL and within the 50 %-150 % range from 36 % to 69 % at 10 ng/mL. These findings underscore SWATH-MS's potential to enhance monitoring of ECs and ecological risk assessments, providing critical insights for environmental management.
Collapse
Affiliation(s)
- Di Xia
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Water Environmental Simulation and Pollution Control, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Guofang Pan
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Water Environmental Simulation and Pollution Control, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Yaxiong Liu
- NMPA Key Laboratory of Rapid Drug Inspection Technology, Guangzhou 510663, China
| | - He Liu
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Water Environmental Simulation and Pollution Control, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Bo Zhao
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Water Environmental Simulation and Pollution Control, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Jiahui Wu
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Water Environmental Simulation and Pollution Control, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Ting Tang
- School of Environment and Energy, South China University of Technology, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China
| | - Guining Lu
- School of Environment and Energy, South China University of Technology, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China
| | - Rui Wang
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Water Environmental Simulation and Pollution Control, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia.
| |
Collapse
|
2
|
Pitterl F, Pavlic M, Liu J, Oberacher H. Insights into the human metabolism of hexahydrocannabinol by non-targeted liquid chromatography-high-resolution tandem mass spectrometry. J Anal Toxicol 2024; 48:350-358. [PMID: 38687640 PMCID: PMC11165647 DOI: 10.1093/jat/bkae022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 02/14/2024] [Accepted: 03/27/2024] [Indexed: 05/02/2024] Open
Abstract
Hexahydrocannabinol (HHC), 6,6,9-trimethyl-3-pentyl-6a,7,8,9,10,10a-hexahydrobenzo[c]chromen-1-ol, is a semi-synthetic cannabinoid that has presented challenges to analytical laboratories due to its emergence and spread in the drug market. The lack of information on human pharmacokinetics hinders the development and application of presumptive and confirmatory tests for reliably detecting HHC consumption. To address this knowledge gap, we report the analytical results obtained from systematic forensic toxicological analysis of body-fluid samples collected from three individuals suspected of drug-impaired driving after HHC consumption. Urine and plasma samples were analyzed using non-targeted liquid chromatography-high-resolution tandem mass spectrometry. The results provided evidence that HHC undergoes biotransformation reactions similar to other well-characterized cannabinoids, such as ∆9-tetrahydrocannabinol or cannabidiol. Notably, HHC itself was only detectable in plasma samples, not in urine samples. The observed Phase I reactions involved oxidation of C11 and the pentyl side chain, leading to corresponding hydroxylated and carboxylic acid species. Additionally, extensive glucuronidation of HHC and its Phase I metabolites was evident.
Collapse
Affiliation(s)
- Florian Pitterl
- Institute of Legal Medicine, Medical University of Innsbruck, Muellerstrasse 44, Innsbruck 6020, Austria
| | - Marion Pavlic
- Institute of Legal Medicine, Medical University of Innsbruck, Muellerstrasse 44, Innsbruck 6020, Austria
| | - Jianmei Liu
- Forensic Chemistry Division, Cayman Chemical Company, 1180 E Ellsworth Rd., Ann Arbor, MI 48108, USA
| | - Herbert Oberacher
- Institute of Legal Medicine, Medical University of Innsbruck, Muellerstrasse 44, Innsbruck 6020, Austria
- Core Facility Metabolomics, Medical University of Innsbruck, Muellerstrasse 44, Innsbruck 6020, Austria
| |
Collapse
|
3
|
Bates MN, Helm AE, Barkholtz HM. Screening for Forensically Relevant Drugs Using Data-Independent High-Resolution Mass Spectrometry. Chem Res Toxicol 2024; 37:571-579. [PMID: 38575522 PMCID: PMC11022238 DOI: 10.1021/acs.chemrestox.3c00379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 03/12/2024] [Accepted: 03/25/2024] [Indexed: 04/06/2024]
Abstract
Forensic and clinical laboratories are expected to provide a rapid screening of samples for a wide range of analytes; however, the ever-changing landscape of illicit substances makes analysis complicated. There is a great need for untargeted methods that can aid these laboratories in broad-scope drug screening. Liquid chromatography hyphenated with high-resolution mass spectrometry (LC-HRMS) has become a popular technique for untargeted screening and presumptive identification of drugs of abuse due to its superior sensitivity and detection capabilities in complex matrices. An untargeted extraction and data acquisition method was evaluated for the broad screening of high-priority drugs of abuse in whole blood. A total of 35 forensically relevant target analytes were identified and extracted at biologically relevant low and high (10× low) concentrations from whole blood using supported liquid extraction. Data-independent acquisition was accomplished using ultraperformance liquid chromatography and a quadrupole time-of-flight mass spectrometry. Results were acceptable for screening assays, with limits of detection at or below the recommended low-concentration cutoffs for most analytes. Analyte ionization varied from 30.1 to 267.6% (average: 110.5%) at low concentrations and from 8.6 to 383.5% (average: 93.6%) at high concentrations. Extraction recovery ranged from 8.5 to 330.5% (average: 105.3%) at low concentrations and from 9.4 to 127.5% (average: 82.7%) at high concentrations. This variability was also captured as precision, ranging from 4.7 to 135.2% (average: 36.5%) at low concentrations and from 0.9 to 59.0% (average: 21.7%) at high concentrations. The method described in this work is efficient and effective for qualitative forensic toxicology screening, as demonstrated by analysis of 166 authentic suspected impaired driver and postmortem specimens. That said, it is critical that laboratories establishing untargeted LC-HRMS screening assays be aware of the strengths and limitations across diverse drug categories and chemical structures.
Collapse
Affiliation(s)
- Maia N. Bates
- Department
of Chemistry, College of Letters and Science, University of Wisconsin-Madison, 1101 University Avenue, Madison, Wisconsin 53706, United States
- Forensic
Toxicology Section, Environmental Health Division, Wisconsin State Laboratory of Hygiene, 2601 Agriculture Drive, Madison, Wisconsin 53718, United States
| | - Abby E. Helm
- Pharmaceutical
Sciences Division, School of Pharmacy, University
of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53705, United States
| | - Heather M. Barkholtz
- Forensic
Toxicology Section, Environmental Health Division, Wisconsin State Laboratory of Hygiene, 2601 Agriculture Drive, Madison, Wisconsin 53718, United States
- Pharmaceutical
Sciences Division, School of Pharmacy, University
of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53705, United States
| |
Collapse
|
4
|
Guan F, You Y, Fay S, Adreance MA, McGoldrick LK, Robinson MA. Factors affecting untargeted detection of doping agents in biological samples. Talanta 2023; 258:124446. [PMID: 36940570 DOI: 10.1016/j.talanta.2023.124446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 03/06/2023] [Accepted: 03/09/2023] [Indexed: 03/12/2023]
Abstract
Doping control is essential for sports, and untargeted detection of doping agents (UDDA) is the holy grail for anti-doping strategies. The present study examined major factors impacting UDDA with metabolomic data processing, including the use of blank samples, signal-to-noise ratio thresholds, and the minimum chromatographic peak intensity. Contrary to data processing in metabolomics studies, both blank sample use (either blank solvent or plasma) and marking of background compounds were found to be unnecessary for UDDA in biological samples, the first such report to the authors' knowledge. The minimum peak intensity required to detect chromatographic peaks affected the limit of detection (LOD) and data processing time for untargeted detection of 57 drugs spiked into equine plasma. The ratio of the mean (ROM) of the extracted ion chromatographic peak area of a compound in the sample group (SG) to that in the control group (CG) impacted its LOD, and a small ROM value such as 2 is recommended for UDDA. Mathematical modeling of the required signal-to-noise ratio (S/N) for UDDA provided insights into the effect of the number of samples in the SG, the number of positive samples, and the ROM on the required S/N, highlighting the power of mathematics in addressing issues in analytical chemistry. The UDDA method was validated by its successful identification of untargeted doping agents in real-world post-competition equine plasma samples. This advancement in UDDA methodology will be a useful addition to the arsenal of approaches used to combat doping in sports.
Collapse
Affiliation(s)
- Fuyu Guan
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, USA; Pennsylvania Equine Toxicology and Research Laboratory, 220 East Rosedale Avenue, West Chester, PA, 19382, USA.
| | - Youwen You
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, USA; Pennsylvania Equine Toxicology and Research Laboratory, 220 East Rosedale Avenue, West Chester, PA, 19382, USA
| | - Savannah Fay
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, USA; Pennsylvania Equine Toxicology and Research Laboratory, 220 East Rosedale Avenue, West Chester, PA, 19382, USA
| | - Matthew A Adreance
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, USA; Pennsylvania Equine Toxicology and Research Laboratory, 220 East Rosedale Avenue, West Chester, PA, 19382, USA
| | - Leif K McGoldrick
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, USA; Pennsylvania Equine Toxicology and Research Laboratory, 220 East Rosedale Avenue, West Chester, PA, 19382, USA
| | - Mary A Robinson
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, USA; Pennsylvania Equine Toxicology and Research Laboratory, 220 East Rosedale Avenue, West Chester, PA, 19382, USA
| |
Collapse
|
5
|
Yang Y, Yang L, Zheng M, Cao D, Liu G. Data acquisition methods for non-targeted screening in environmental analysis. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
|
6
|
Hao Y, Lynch K, Fan P, Jurtschenko C, Cid M, Zhao Z, Yang HS. Development of a Machine Learning Algorithm for Drug Screening Analysis on High-Resolution UPLC-MSE/QTOF Mass Spectrometry. J Appl Lab Med 2023; 8:53-66. [PMID: 36610415 DOI: 10.1093/jalm/jfac100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 09/21/2022] [Indexed: 01/09/2023]
Abstract
BACKGROUND Ultra-performance liquid chromatography (UPLC)-MSE/quadrupole time-of-flight (QTOF) high-resolution mass spectrometry employs untargeted, data-independent acquisition in a dual mode that simultaneously collects precursor ions and product ions at low and ramped collision energies, respectively. However, algorithmic analysis of large-scale multivariate data of comprehensive drug screening as well as the positivity criteria of drug identification have not been systematically investigated. It is also unclear whether ion ratio (IR), the intensity ratio of a defined product ion divided by the precursor ion, is a stable parameter that can be incorporated into the MSE/QTOF data analysis algorithm. METHODS IR of 91 drugs were experimentally determined and variation of IR was investigated across 5 concentrations measured on 3 different days. A data-driven machine learning approach was employed to develop multivariate linear regression (MLR) models incorporating mass error, retention time, number of detected fragment ions and IR, accuracy of isotope abundance, and peak response using drug-supplemented urine samples. Performance of the models was evaluated in an independent data set of unknown clinical urine samples in comparison with the results of manual analysis. RESULTS IR of most compounds acquired by MSE/QTOF were low and concentration-dependent (i.e., IR increased at higher concentrations). We developed an MLR model with composite score outputs incorporating 7 parameters to predict positive drug identification. The model achieved a mean accuracy of 89.38% in the validation set and 87.92% agreement in the test set. CONCLUSIONS The MLR model incorporating all contributing parameters can serve as a decision-support tool to facilitate objective drug identification using UPLC-MSE/QTOF.
Collapse
Affiliation(s)
- Ying Hao
- Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, NY, USA
| | - Kara Lynch
- Department of Pathology and Laboratory Medicine, University of California, San Francisco, San Francisco, CA, USA
| | - Pengcheng Fan
- Proteomics and Metabolomics Core Laboratory, Weill Cornell Medicine, New York, NY
| | | | - Maria Cid
- Toxicology and Therapeutic Drug Monitoring Laboratory, New York-Presbyterian Hospital, Weill Cornell Medicine Center, New York, NY, USA
| | - Zhen Zhao
- Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, NY, USA.,Toxicology and Therapeutic Drug Monitoring Laboratory, New York-Presbyterian Hospital, Weill Cornell Medicine Center, New York, NY, USA
| | - He S Yang
- Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, NY, USA.,Toxicology and Therapeutic Drug Monitoring Laboratory, New York-Presbyterian Hospital, Weill Cornell Medicine Center, New York, NY, USA
| |
Collapse
|
7
|
Wille SMR, Desharnais B, Pichini S, Trana AD, Busardò FP, Wissenbach DK, Peters FT. Liquid Chromatography High Resolution Mass Spectrometry in Forensic Toxicology: What Are the Specifics of Method Development, Validation and Quality Assurance for Comprehensive Screening Approaches? Curr Pharm Des 2022; 28:1230-1244. [PMID: 35619258 DOI: 10.2174/1381612828666220526152259] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 04/12/2022] [Indexed: 11/22/2022]
Abstract
The use of High Resolution Mass Spectrometry (HRMS) has increased over the past decade in clinical and forensic toxicology, especially for comprehensive screening approaches. Despite this, few guidelines of this field have specifically addressed HRMS issues concerning compound identification, validation, measurement uncertainty and quality assurance. To fully implement this technique, certainly in an era in which the quality demands for laboratories are ever increasing due to various norms (e.g. the International Organization for Standardization's ISO 17025), these specific issues need to be addressed. This manuscript reviews 26 HRMS-based methods for qualitative systematic toxicological analysis (STA) published between 2011 and 2021. Key analytical data such as samples matrices, analytical platforms, numbers of analytes and employed mass spectral reference databases/libraries as well as the studied validation parameters are summarized and discussed. The article further includes a critical review of targeted and untargeted data acquisition approaches, available HRMS reference databases and libraries as well as current guidelines for HRMS data interpretation with a particular focus on identification criteria. Moreover, it provides an overview on current recommendations for the validation and determination measurement uncertainty of qualitative methods. Finally, the article aims to put forward suggestions for method development, compound identification, validation experiments to be performed, and adequate determination of measurement uncertainty for this type of wide-range qualitative HRMS-based methods.
Collapse
Affiliation(s)
- Sarah M R Wille
- Unit Toxicology, National Institute of Criminalistics and Criminology (NICC), Brussels, Belgium
| | - Brigitte Desharnais
- Laboratoire de sciences judiciaires et de médecine légale, Department of Toxicology, 1701 Parthenais St., Montréal, Québec, H2K 3S7, Canada
| | - Simona Pichini
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy
| | - Annagiulia Di Trana
- Department of Excellence of Biomedical Sciences and Public Health, University "Politecnica delle Marche", Ancona, Italy
| | - Francesco Paolo Busardò
- Department of Excellence of Biomedical Sciences and Public Health, University "Politecnica delle Marche", Ancona, Italy
| | - Dirk K Wissenbach
- Institute of Forensic Medicine, Jena University Hospital, Jena, Germany
| | | |
Collapse
|
8
|
Kim C, Wang X, Kültz D. Prediction and Experimental Validation of a New Salinity-Responsive Cis-Regulatory Element (CRE) in a Tilapia Cell Line. Life (Basel) 2022; 12:787. [PMID: 35743818 PMCID: PMC9225295 DOI: 10.3390/life12060787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 05/12/2022] [Accepted: 05/16/2022] [Indexed: 11/16/2022] Open
Abstract
Transcriptional regulation is a major mechanism by which organisms integrate gene x environment interactions. It can be achieved by coordinated interplay between cis-regulatory elements (CREs) and transcription factors (TFs). Euryhaline tilapia (Oreochromis mossambicus) tolerate a wide range of salinity and thus are an appropriate model to examine transcriptional regulatory mechanisms during salinity stress in fish. Quantitative proteomics in combination with the transcription inhibitor actinomycin D revealed 19 proteins that are transcriptionally upregulated by hyperosmolality in tilapia brain (OmB) cells. We searched the extended proximal promoter up to intron1 of each corresponding gene for common motifs using motif discovery tools. The top-ranked motif identified (STREME1) represents a binding site for the Forkhead box TF L1 (FoxL1). STREME1 function during hyperosmolality was experimentally validated by choosing two of the 19 genes, chloride intracellular channel 2 (clic2) and uridine phosphorylase 1 (upp1), that are enriched in STREME1 in their extended promoters. Transcriptional induction of these genes during hyperosmolality requires STREME1, as evidenced by motif mutagenesis. We conclude that STREME1 represents a new functional CRE that contributes to gene x environment interactions during salinity stress in tilapia. Moreover, our results indicate that FoxL1 family TFs are contribute to hyperosmotic induction of genes in euryhaline fish.
Collapse
Affiliation(s)
- Chanhee Kim
- Stress-Induced Evolution Laboratory, Department of Animal Sciences, University of California, Davis, CA 95616, USA;
| | - Xiaodan Wang
- Laboratory of Aquaculture Nutrition and Environmental Health, School of Life Sciences, East China Normal University, Shanghai 200241, China;
| | - Dietmar Kültz
- Stress-Induced Evolution Laboratory, Department of Animal Sciences, University of California, Davis, CA 95616, USA;
| |
Collapse
|
9
|
Zarrouk E, Lenski M, Bruno C, Thibert V, Contreras P, Privat K, Ameline A, Fabresse N. High-resolution mass spectrometry: Theoretical and technological aspects. TOXICOLOGIE ANALYTIQUE ET CLINIQUE 2022. [DOI: 10.1016/j.toxac.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
10
|
Tian T, Zhou BW, Wu LH, Zhang F, Chou GX, Feng CG, Lin GQ. Non-targeted screening of pyranosides in Rhodiola crenulata using an all ion fragmentation-exact neutral loss strategy combined with liquid chromatography-quadrupole time-of-flight mass spectrometry. PHYTOCHEMICAL ANALYSIS : PCA 2021; 32:1039-1050. [PMID: 33779008 DOI: 10.1002/pca.3045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 02/08/2021] [Accepted: 03/03/2021] [Indexed: 06/12/2023]
Abstract
INTRODUCTION Pyranosides as one kind of natural glycosides contain a pyran ring linked to an aglycone in the structure. They occur widely in plants and possess diverse biological activities. The discovery of new pyranosides not only contributes to research on natural products but also may promote pharmaceutical development. OBJECTIVES A non-targeted liquid chromatography-quadrupole time-of-flight mass spectrometry method coupled with an all ion fragmentation-exact neutral loss (AIF-ENL) strategy was developed for the screening of pyranosides in plants. METHODS Pyranosides in various types were collected as a model. The AIF-ENL strategy comprised three steps: AIF spectrum acquisition and generation, ENL-based searching and identification, and confirmation of structural type using target second-stage mass spectrometry (MS/MS). The strategy was systematically evaluated based on the matrix effects, fragmentation stability, scan rate and screening efficiency and finally applied to Rhodiola crenulata (Hook. f. et Thoms) H. Ohba. RESULTS The method was proved to be an efficient tool for the screening of pyranosides. When it was applied to R. crenulata, a total of 24 pyranoside candidates were detected. Among them, six were tentatively identified on the basis of the agreement of their elemental composition with the reported. The other 18 were detected in R. crenulata for the first time. CONCLUSION The method offers a new platform for discovering pyranosides. In addition, the developed non-targeted strategy can also be used for other natural products, such as flavonoids and coumarins, as long as there is a common fragmentation behaviour in their MS/MS to generate characteristic neutral losses or fragments.
Collapse
Affiliation(s)
- Tian Tian
- The Research Centre of Chiral Drugs, Innovation Research Institute of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Bo-Wen Zhou
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, China
| | - Li-Hong Wu
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Fang Zhang
- The Research Centre of Chiral Drugs, Innovation Research Institute of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, China
| | - Gui-Xin Chou
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Chen-Guo Feng
- The Research Centre of Chiral Drugs, Innovation Research Institute of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, China
| | - Guo-Qiang Lin
- The Research Centre of Chiral Drugs, Innovation Research Institute of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, China
| |
Collapse
|
11
|
Stempfer M, Reinstadler V, Lang A, Oberacher H. Analysis of cannabis seizures by non-targeted liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 2021; 205:114313. [PMID: 34474231 DOI: 10.1016/j.jpba.2021.114313] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 07/30/2021] [Accepted: 08/04/2021] [Indexed: 02/06/2023]
Abstract
Due to the popularity of recreational cannabis use, contamination of this drug with diverse classes of chemicals, including pesticides, mycotoxins, and synthetic cannabinoids, has been identified as major threat for public health. For the detection of these compounds in seized cannabis, a screening workflow involving non-targeted liquid chromatography-tandem mass spectrometry (LCMS/MS) was developed. A Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method was used for the extraction of small bioorganic molecules from ground dried material. Instrumental analysis involved chromatographic separation of compounds and subsequent mass spectrometric detection. Collection of MS and MS/MS information was accomplished by data-dependent acquisition. Compound identification was primarily based on matching acquired MS/MS-spectra to several thousands of reference spectra stored in multiple libraries. Additionally, for selected cannabinoid and pesticide standards, a retention time library was developed. Performance of the workflow was evaluated for 182 pesticides. All tested pesticides were detectable at 5000 μg/kg, 94 % at 500 μg/kg, and 50 % at 50 μg/kg. The workflow was applied to the screening of seized cannabis samples. 41 out of 93 analysed samples (44 %) were tested positive for one or more contaminants impairing quality and/or safety of the material. The detected contaminants included a synthetic cannabinoid (5F-MDMB-PINACA), fifteen pesticide residues (boscalid, carbendazim, chlorantraniliprole, chlorpyrifos, chlorotoluron, cyprodinil, diflubenzuron, ethiofencarb sulfoxide, hexythiazox, iprodione, metalaxyl, pyrimethanil, terbutryn, thiophanate methyl, and trifloxystrobin), and a mycotoxin (sterigmatocystin).
Collapse
Affiliation(s)
- Miriam Stempfer
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Mullerstrasse 44, 6020, Innsbruck, Austria
| | - Vera Reinstadler
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Mullerstrasse 44, 6020, Innsbruck, Austria
| | - Anna Lang
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Mullerstrasse 44, 6020, Innsbruck, Austria
| | - Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Mullerstrasse 44, 6020, Innsbruck, Austria.
| |
Collapse
|
12
|
Anxiety disturbs the blood plasma metabolome in acute coronary syndrome patients. Sci Rep 2021; 11:12897. [PMID: 34145340 PMCID: PMC8213718 DOI: 10.1038/s41598-021-92421-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 05/31/2021] [Indexed: 01/14/2023] Open
Abstract
Coronary heart disease (CHD) is the result of a complex metabolic disorder caused by various environmental and genetic factors, and often has anxiety as a comorbidity. Rupture of atherosclerotic plaque in CHD patients can lead to acute coronary syndrome (ACS). Anxiety is a known independent risk factor for the adverse cardiovascular events and mortality in ACS, but it remains unclear how stress-induced anxiety behavior impacts their blood plasma metabolome and contributes to worsening of CHD. The present study aimed to determine the effect of anxiety on the plasma metabolome in ACS patients. After receiving ethical approval 26 ACS patients comorbid anxiety were recruited and matched 26 ACS patients. Blood plasma samples were collected from the patients and stored at − 80 °C until metabolome profiling. Metabolome analysis was performed by liquid chromatography mass spectrometry (LC–MS), and the data were subjected to multivariate analysis. Disturbance of 39 plasma metabolites was noted in the ACS with comorbid anxiety group compared to the ACS group. These disturbed metabolites were mainly involved in tryptophan metabolism, pyrimidine metabolism, glycerophospholipid metabolism, pentose phosphate pathway, and pentose and glucuronate interconversions. The most significantly affected pathway was tryptophan metabolism including the down-regulation of tryptophan and serotonin. Glycerophospholipids metabolism, pentose and glucuronate interconversions, and pentose phosphate pathway were also greatly affected. These results suggest that anxiety can disturb three translation of material in ACS patients. Besides the above metabolism pathways pyrimidine metabolism was significantly disturbed. Based on the present findings the plasma metabolites monitoring can be recommended and may be conducive to early biomarkers detection for personalized treatment anxiety in CHD patients in future.
Collapse
|
13
|
Kleis J, Hess C, Germerott T, Roehrich J. Sensitive Screening of New Psychoactive Substances in Serum Using Liquid-Chromatography Quadrupole Time-of-Flight Mass Spectrometry. J Anal Toxicol 2021; 46:592-599. [PMID: 34125215 DOI: 10.1093/jat/bkab072] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 06/10/2021] [Accepted: 06/12/2021] [Indexed: 01/18/2023] Open
Abstract
Analysis of new psychoactive substances (NPS) still pose a challenge for many institutions due to the number of available substances and the constantly changing drug market. Both new and well-known substances keep appearing and disappearing on the market, making it hard to adapt analytical methods in a timely manner. In this study we developed a qualitative screening approach for serum samples by means of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS). Samples were measured in data-dependent auto-MS/MS mode and identified by fragment spectra comparison, retention time and accurate mass. Approximately 500 NPS, including 195 synthetic cannabinoids, 180 stimulants, 86 hallucinogens, 26 benzodiazepines and 7 others were investigated. Serum samples were fortified to 1 ng/mL and 10 ng/mL concentrations to estimate approximate limits of identification. Samples were extracted using solid-phase extraction with non-endcapped C18 material and elution in two consecutive steps. Benzodiazepines were eluted in the first step, while substances of other NPS subclasses were distributed among both extracts. To determine limits of identification, both extracts were combined. 96 % (470/492) of investigated NPS were detected in 10 ng/mL samples and 88 % (432/492) were detected in 1 ng/mL samples. Stimulants stood out with higher limits of identification, possibly due to instability of certain methcathinone derivatives. However, considering relevant blood concentrations, the method provided sufficient sensitivity for stimulants as well as other NPS subclasses. Data-dependent acquisition was proven to provide high sensitivity and reliability when combined with an information-dependent preferred list, without losing its untargeted operation principle. Summarizing, the developed method fulfilled its purpose as a sensitive untargeted screening for serum samples and allows uncomplicated expansion of the spectral library to include thousands of targets.
Collapse
Affiliation(s)
- J Kleis
- Institute of Forensic Medicine, Forensic Toxicology, Johannes Gutenberg University Mainz, Mainz, Germany
| | - C Hess
- Institute of Forensic Medicine, Forensic Toxicology, Johannes Gutenberg University Mainz, Mainz, Germany
| | - T Germerott
- Institute of Forensic Medicine, Forensic Toxicology, Johannes Gutenberg University Mainz, Mainz, Germany
| | - J Roehrich
- Institute of Forensic Medicine, Forensic Toxicology, Johannes Gutenberg University Mainz, Mainz, Germany
| |
Collapse
|
14
|
Root L, Campo A, MacNiven L, Con P, Cnaani A, Kültz D. A data-independent acquisition (DIA) assay library for quantitation of environmental effects on the kidney proteome of Oreochromis niloticus. Mol Ecol Resour 2021; 21:2486-2503. [PMID: 34101993 DOI: 10.1111/1755-0998.13445] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 04/30/2021] [Accepted: 06/01/2021] [Indexed: 12/31/2022]
Abstract
Interactions of organisms with their environment are complex and environmental regulation at different levels of biological organization is often nonlinear. Therefore, the genotype to phenotype continuum requires study at multiple levels of organization. While studies of transcriptome regulation are now common for many species, quantitative studies of environmental effects on proteomes are needed. Here we report the generation of a data-independent acquisition (DIA) assay library that enables simultaneous targeted proteomics of thousands of Oreochromis niloticus kidney proteins using a label- and gel-free workflow that is well suited for ecologically relevant field samples. We demonstrate the usefulness of this DIA assay library by discerning environmental effects on the kidney proteome of O. niloticus. Moreover, we demonstrate that the DIA assay library approach generates data that are complimentary rather than redundant to transcriptomic data. Transcript and protein abundance differences in kidneys of tilapia acclimated to freshwater and brackish water (25 g/kg) were correlated for 2114 unique genes. A high degree of non-linearity in salinity-dependent regulation of transcriptomes and proteomes was revealed suggesting that the regulation of O. niloticus renal function by environmental salinity relies heavily on post-transcriptional mechanisms. The application of functional enrichment analyses using STRING and KEGG to DIA assay data sets is demonstrated by identifying myo-inositol metabolism, antioxidant and xenobiotic functions, and signalling mechanisms as key elements controlled by salinity in tilapia kidneys. The DIA assay library resource presented here can be adopted for other tissues and other organisms to study proteome dynamics during changing ecological contexts.
Collapse
Affiliation(s)
- Larken Root
- Department of Animal Sciences, University of California Davis, Davis, CA, USA
| | - Aurora Campo
- Department of Poultry and Aquaculture, Institute of Animal Sciences, Agricultural Research Organization, Volcani Center, Rishon LeZion, Israel
| | - Leah MacNiven
- Department of Animal Sciences, University of California Davis, Davis, CA, USA
| | - Pazit Con
- Department of Poultry and Aquaculture, Institute of Animal Sciences, Agricultural Research Organization, Volcani Center, Rishon LeZion, Israel
| | - Avner Cnaani
- Department of Poultry and Aquaculture, Institute of Animal Sciences, Agricultural Research Organization, Volcani Center, Rishon LeZion, Israel
| | - Dietmar Kültz
- Department of Animal Sciences, University of California Davis, Davis, CA, USA
| |
Collapse
|
15
|
Polettini AE, Kutzler J, Sauer C, Guber S, Schultis W. LC-QTOF-MS Presumptive Identification of Synthetic Cannabinoids without Reference Chromatographic Retention/Mass Spectral Information. II. Evaluation of a Computational Approach for Predicting and Identifying Unknown High-Resolution Product Ion Mass Spectra. J Anal Toxicol 2021; 45:440-461. [PMID: 32896859 DOI: 10.1093/jat/bkaa127] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 08/17/2020] [Accepted: 09/03/2020] [Indexed: 11/14/2022] Open
Abstract
Despite liquid chromatography-high-resolution tandem mass spectrometry (MS2) enables untargeted acquisition, data processing in toxicological screenings is almost invariably performed in targeted mode. We developed a computational approach based on open source chemometrics software that, starting from a suspected synthetic cannabinoid (SC) determined formula, searches for isomers in different new psychoactive substances web databases, predicts retention time (RT) and high-resolution MS2 spectrum, and compares them with the unknown providing a rank-ordered candidates list. R was applied on 105 SC measured data to develop and validate a multiple linear regression quantitative structure-activity relationship model predicting RT. Competitive Fragmentation Modeling for Metabolite Identification (CFM-ID) freeware was used to predict/compare spectra with Jaccard similarity index. Data-dependent acquisition was performed with an Agilent Infinity 1290 LC-6550 iFunnel Q-TOF MS with ZORBAX Eclipse-Plus C18 (100 × 2.1 mm2/1.8 µm) in water/acetonitrile/ammonium formate gradient. Ability of the combined RT/MS2 prediction to identify unknowns was evaluated on SC standards (with leave-one-out from the RT model) and on unexpected SC encountered in real cases. RT prediction reduced the number of isomers retrieved from a group of new psychoactive substances web databases to one-third (2,792 ± 3,358→845 ± 983) and differentiated between SC isomers when spectra were not selective (4F-MDMB-BUTINACA, 4F-MDMB-BUTINACA 2'-indazole isomer) or unavailable (4CN-Cumyl-B7AICA, 4CN-Cumyl-BUTINACA). When comparing 30/40 eV measured spectra of 99 SC against RT-selected, CFM-ID predicted spectra of isomers, the right candidate ranked 1st on median and 4th on average; 54% and 88% of times the right match ranked 1st or within the first 5 matches, respectively. To our knowledge, this is the first case of extensive chemometrics application to toxicological screening. In most cases, presumptive identification (being based on computation, it requires further information for confirmation) of unexpected SC was achieved without reference measured information. This method is currently the closest possible to true unbiased/untargeted screening. The bottleneck of the method is the processing time required to predict mass spectra (ca. 30-35 s/compound using a 64-bit 2.50-GHz Intel® Core™ i5-7200U CPU). However, strategies can be implemented to reduce prediction processing time.
Collapse
Affiliation(s)
- Aldo E Polettini
- Department of Diagnostics & Public Health, University of Verona, 371334 Verona, Italy.,Department of Toxicology and Forensic Toxicology, Synlab MVZ Weiden GmbH, 92637 Weiden, Germany
| | - Johannes Kutzler
- Department of Toxicology and Forensic Toxicology, Synlab MVZ Weiden GmbH, 92637 Weiden, Germany
| | - Christoph Sauer
- Department of Toxicology and Forensic Toxicology, Synlab MVZ Weiden GmbH, 92637 Weiden, Germany
| | - Susanne Guber
- Department of Toxicology and Forensic Toxicology, Synlab MVZ Weiden GmbH, 92637 Weiden, Germany
| | - Wolfgang Schultis
- Department of Toxicology and Forensic Toxicology, Synlab MVZ Weiden GmbH, 92637 Weiden, Germany
| |
Collapse
|
16
|
González-Gaya B, Lopez-Herguedas N, Bilbao D, Mijangos L, Iker AM, Etxebarria N, Irazola M, Prieto A, Olivares M, Zuloaga O. Suspect and non-target screening: the last frontier in environmental analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1876-1904. [PMID: 33913946 DOI: 10.1039/d1ay00111f] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Suspect and non-target screening (SNTS) techniques are arising as new analytical strategies useful to disentangle the environmental occurrence of the thousands of exogenous chemicals present in our ecosystems. The unbiased discovery of the wide number of substances present over environmental analysis needs to find a consensus with powerful technical and computational requirements, as well as with the time-consuming unequivocal identification of discovered analytes. Within these boundaries, the potential applications of SNTS include the studies of environmental pollution in aquatic, atmospheric, solid and biological samples, the assessment of new compounds, transformation products and metabolites, contaminant prioritization, bioremediation or soil/water treatment evaluation, and retrospective data analysis, among many others. In this review, we evaluate the state of the art of SNTS techniques going over the normalized workflow from sampling and sample treatment to instrumental analysis, data processing and a brief review of the more recent applications of SNTS in environmental occurrence and exposure to xenobiotics. The main issues related to harmonization and knowledge gaps are critically evaluated and the challenges of their implementation are assessed in order to ensure a proper use of these promising techniques in the near future.
Collapse
Affiliation(s)
- B González-Gaya
- Department of Analytical Chemistry, University of the Basque Country (UPV/EHU), 48940 Leioa, Basque Country, Spain.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Di Rago M, Pantatan S, Hargreaves M, Wong K, Mantinieks D, Kotsos A, Glowacki L, Drummer OH, Gerostamoulos D. High Throughput Detection of 327 Drugs in Blood by LC-MS-MS with Automated Data Processing. J Anal Toxicol 2021; 45:154-183. [PMID: 32451548 DOI: 10.1093/jat/bkaa057] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 01/20/2020] [Accepted: 04/19/2020] [Indexed: 12/17/2022] Open
Abstract
The described procedure provides a rapid technique for the detection and semi-quantitation of a large number of drugs in blood. This procedure uses a minimal sample volume and employs a one-step liquid extraction and automated data processing to yield rapid turnaround times. A total of 327 of the most commonly used medicinal and illicit drugs in Australia were selected including various amphetamines, anesthetics, antidepressants, antipsychotics, anticonvulsants, benzodiazepines, beta blockers, opioid and nonopioid analgesics, stimulants, THC and a large number of synthetic cannabinoids and other novel psychoactive substances. The extracts were subject to 5-minute chromatography using a Kinetex C18 50 × 4.6 mm 2.6 μm solid-core analytical column and analyzed using a Sciex 3200 Q-TRAP MS-MS (+ ESI, MRM mode, two transitions per analyte). The method was fully validated in accordance with international guidelines. Matrix effects and extraction efficiencies were acceptable with most analytes showing > 80% response and low variation (within 25%RSD). Cannabinoids were most affected by the matrix and yielded poorest recovery values but were still detectable. Precision, accuracy, repeatability and multipoint linearity were assessed for all analytes. The method has been used in routine practice in the forensic toxicology service at the Victorian Institute of Forensic Medicine in over 6000 coronial investigations using both postmortem and clinical blood specimens. This technique has greatly increased throughput, reduced turnaround times and allowed for rapid same-day analysis of results when needed. The method is routinely used in routine overnight testing with results reported to pathologists within 4 h of data acquisition. This rapid toxicological technique is used in conjunction with other investigative processes such as full-body CT imaging, review of case circumstances and medical histories to provide an efficient death investigation process.
Collapse
Affiliation(s)
- Matthew Di Rago
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia.,Department of Forensic Medicine, Monash University, Clayton, Victoria, Australia
| | - Supranee Pantatan
- Toxicology, Central Institute of Forensic Science, Bangkok, Thailand
| | - Melynda Hargreaves
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia
| | - Katherine Wong
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia
| | - Dylan Mantinieks
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia.,Department of Forensic Medicine, Monash University, Clayton, Victoria, Australia
| | - Alex Kotsos
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia
| | - Linda Glowacki
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia
| | - Olaf H Drummer
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia.,Department of Forensic Medicine, Monash University, Clayton, Victoria, Australia
| | - Dimitri Gerostamoulos
- Toxicology, Victorian Institute of Forensic Medicine, Southbank, Victoria, Australia.,Department of Forensic Medicine, Monash University, Clayton, Victoria, Australia
| |
Collapse
|
18
|
Abstract
Synthetic drugs of abuse contain various psychoactive substances. These substances have recently emerged as novel drugs of abuse in public; thus, they are known as novel psychoactive substances (NPS). As these compounds are artificially synthesized in a laboratory, they are also called designer drugs. Synthetic cannabinoids and synthetic cathinones are the two primary classes of NPS or designer drugs. Synthetic cannabinoids, also known as "K2" or "Spice," are potent agonists of the cannabinoid receptors. Synthetic cathinones, known as "Bath salts," are beta-keto amphetamine derivatives. These compounds can cause severe intoxication, including overdose deaths. NPS are accessible locally and online. NPS are scheduled in the US and other countries, but the underground chemists keep modifying the chemical structure of these compounds to avoid legal regulation; thus, these compounds have been evolving rapidly. These drugs are not detectable by traditional drug screening, and thus, these substances are mainly abused by young individuals and others who wish to avoid drug detection. These compounds are analyzed primarily by mass spectrometry.
Collapse
|
19
|
Guo Z, Huang S, Wang J, Feng YL. Recent advances in non-targeted screening analysis using liquid chromatography - high resolution mass spectrometry to explore new biomarkers for human exposure. Talanta 2020; 219:121339. [DOI: 10.1016/j.talanta.2020.121339] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 05/16/2020] [Accepted: 06/09/2020] [Indexed: 12/29/2022]
|
20
|
Borden SA, Palaty J, Termopoli V, Famiglini G, Cappiello A, Gill CG, Palma P. MASS SPECTROMETRY ANALYSIS OF DRUGS OF ABUSE: CHALLENGES AND EMERGING STRATEGIES. MASS SPECTROMETRY REVIEWS 2020; 39:703-744. [PMID: 32048319 DOI: 10.1002/mas.21624] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
Mass spectrometry has been the "gold standard" for drugs of abuse (DoA) analysis for many decades because of the selectivity and sensitivity it affords. Recent progress in all aspects of mass spectrometry has seen significant developments in the field of DoA analysis. Mass spectrometry is particularly well suited to address the rapidly proliferating number of very high potency, novel psychoactive substances that are causing an alarming number of fatalities worldwide. This review surveys advancements in the areas of sample preparation, gas and liquid chromatography-mass spectrometry, as well as the rapidly emerging field of ambient ionization mass spectrometry. We have predominantly targeted literature progress over the past ten years and present our outlook for the future. © 2020 Periodicals, Inc. Mass Spec Rev.
Collapse
Affiliation(s)
- Scott A Borden
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
| | - Jan Palaty
- LifeLabs Medical Laboratories, Burnaby, BC, V3W 1H8, Canada
| | - Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Achille Cappiello
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
- Department of Chemistry, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, WA, 98195
| | - Pierangela Palma
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| |
Collapse
|
21
|
Leung DKK, Wong ASY, Zhou QL, Wan TSM, Ho ENM. Application of a non-target variable data independent workflow (vDIA) for the screening of prohibited substances in doping control testing. Drug Test Anal 2020; 13:1008-1033. [PMID: 32568425 DOI: 10.1002/dta.2881] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 06/16/2020] [Accepted: 06/17/2020] [Indexed: 12/24/2022]
Abstract
A non-target variable Data Independent Acquisition (vDIA) workflow based on accurate mass measurements using a Q Exactive OrbiTrap is presented for the first time for equine doping control testing. The vDIA workflow uses a combination of MS1 events (1 to 2) and multiple vDIA events to cover the analytes of interest. The workflow basically captures a digital image of a sample allowing all relevant MS1 and MS2 data to be recorded. In theory, the workflow can accommodate an unlimited number of analytes as long as they are amenable to the sample extraction protocol and fall within the mass limits of the workflow. Additional targets fulfilling the above requirements can be added without changing any settings. The performance of the vDIA workflow was illustrated by applying it to two screening methods in horse urine, with one workflow covering 331 basic drugs and the other covering 45 quaternary ammonium drugs (QADs). Both screening methods have good detection sensitivity with 84% of the basic drugs having Limits of Detection (LoDs) of ≤ 1 ng/mL and 84% of the QADs having LoDs of ≤ 0.4 ng/mL. Other method characteristics including retention reproducibility, method precision and false hit rate will also be presented.
Collapse
Affiliation(s)
- David K K Leung
- Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N. T., Hong Kong, China
| | - April S Y Wong
- Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N. T., Hong Kong, China
| | - Q L Zhou
- Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N. T., Hong Kong, China
| | - Terence S M Wan
- Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N. T., Hong Kong, China
| | - Emmie N M Ho
- Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N. T., Hong Kong, China
| |
Collapse
|
22
|
Zhao J, Zhai X, Ma Y, Zhang T, Wang Z, Chong T. Anatomic characteristics of epididymis based on histology, proteomic, and 3D reconstruction. Andrology 2020; 8:1787-1794. [PMID: 32558146 DOI: 10.1111/andr.12842] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 05/20/2020] [Accepted: 06/09/2020] [Indexed: 11/27/2022]
Abstract
BACKGROUND The epididymis is a popular research topic in urology and reproduction. OBJECTIVES To explore and identify the anatomical characteristics of the epididymis based on histology, proteomics, and 3D reconstruction of epididymal tubules. MATERIALS AND METHODS A 3D reconstruction of epididymal tubules was generated based on 7-μm-thick transverse serial sections of an epididymis. The proteins in the subcompartments of the epididymis were obtained and analyzed by non-labeled sequential window acquisition of all theoretical fragment ion spectra mass spectrometry (SWATH MS). Protein function, signaling pathways, protein expression, and the histology in different subcompartments were analyzed. RESULTS The caput (Cap), corpus (Cor), and cauda (Cau) of the epididymis were divided into 6, 10, and 4 subcompartments, respectively, and the subcompartment between the Cap and Cor is mixed together. A total of 3411 proteins were identified, and 854 proteins were accurately quantified after screening. When the subcompartment Cap 5 transitioned to Cap 6 and Cap 6 to Cap 7, 87 and 52 proteins were upregulated and 14 and 7 proteins were downregulated, respectively. The Cor 9 transition to Cau 1 was marked by 230 proteins that were downregulated, while 74 proteins were upregulated. At the junction of the cauda and the vas deferens, 57 proteins were downregulated, and 410 proteins were upregulated. Cap 6 histology was consistent with that of Cor 1. DISCUSSION AND CONCLUSION The epididymis contains distinct connective tissue septa that can be identified under a surgical tabletop microscope, enabling it to be divided into 20 subcompartments.
Collapse
Affiliation(s)
- Jun Zhao
- Department of Urology, The Second Affiliated Hospital, Xi'an Jiaotong University, Shaanxi, China
| | - Xiaoqiang Zhai
- Department of Urology, The Second Affiliated Hospital, Xi'an Jiaotong University, Shaanxi, China
| | - Yubo Ma
- Department of Urology, The Second Affiliated Hospital, Xi'an Jiaotong University, Shaanxi, China
| | - Tongdian Zhang
- Department of Urology, The Second Affiliated Hospital, Xi'an Jiaotong University, Shaanxi, China
| | - Ziming Wang
- Department of Urology, The Second Affiliated Hospital, Xi'an Jiaotong University, Shaanxi, China
| | - Tie Chong
- Department of Urology, The Second Affiliated Hospital, Xi'an Jiaotong University, Shaanxi, China
| |
Collapse
|
23
|
Azimi A, Lo K, Kim J, Fernandez-Penas P. Investigating proteome changes between primary and metastatic cutaneous squamous cell carcinoma using SWATH mass spectrometry. J Dermatol Sci 2020; 99:119-127. [PMID: 32651104 DOI: 10.1016/j.jdermsci.2020.06.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 06/14/2020] [Accepted: 06/28/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND Cutaneous squamous cell carcinoma (cSCC) is a common malignancy worldwide and the first as the cause of death from keratinocytic carcinomas. Around 5% of primary cSCCs metastasize, leading to a 5-year survival rate of only 11 %. OBJECTIVE This paper aims to investigate the proteome profile of primary and metastatic cSCC lesions for the identification of potential diagnostic biomarkers and molecular alterations. METHODS Liquid chromatography coupled with SWATH-MS workflow was used to analyse the proteome profile of formalin-fixed and paraffin-embedded samples of primary (n = 20) and metastatic cSCC (n = 25) lesions. Statistical and bioinformatics analysis was performed to identify differentially abundant proteins and molecular alterations between the lesions. RESULTS A total of 5037 proteins were identified across the samples of which 19 proteins including ISG15, APOA1 and MARCKS with roles in metastasis were increased and 11 proteins including DMKN, APCS and CST6 decreased in metastatic cSCC lesions relative to the primary phenotypes (adj. p-value <0.05). The proteomic data separated the lesions based on their histopathological diagnosis. Bioinformatics analysis revealed that cell migration, cell survival and immune response are likely activated, and apoptosis is inhibited in metastatic cSCC lesions, indicating increased lesion complexity as the disease progresses from primary to the metastatic phenotype. Two samples were reclassified after PCA analysis. CONCLUSION SWATH-MS analysis identified important molecular changes between primary and metastatic cSCC samples. Exploring these findings further will allow their translation into the clinic for improved tumour diagnosis, staging and therapeutic intervention.
Collapse
Affiliation(s)
- Ali Azimi
- Centre for Translational Skin Research, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales, Australia; Department of Dermatology, Westmead Hospital, Westmead, New South Wales, Australia
| | - Kitty Lo
- School of Mathematics and Statistics, The University of Sydney, Camperdown, New South Wales, Australia
| | - Jennifer Kim
- Department of Tissue Pathology and Diagnostic Oncology, Institute of Clinical Pathology and Medical Research (ICPMR) Westmead Hospital, Westmead, New South Wales, Australia
| | - Pablo Fernandez-Penas
- Centre for Translational Skin Research, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales, Australia; Department of Dermatology, Westmead Hospital, Westmead, New South Wales, Australia.
| |
Collapse
|
24
|
Klont F, Jahn S, Grivet C, König S, Bonner R, Hopfgartner G. SWATH data independent acquisition mass spectrometry for screening of xenobiotics in biological fluids: Opportunities and challenges for data processing. Talanta 2020; 211:120747. [DOI: 10.1016/j.talanta.2020.120747] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 01/11/2020] [Accepted: 01/13/2020] [Indexed: 12/23/2022]
|
25
|
Streun GL, Elmiger MP, Dobay A, Ebert L, Kraemer T. A machine learning approach for handling big data produced by high resolution mass spectrometry after data independent acquisition of small molecules – Proof of concept study using an artificial neural network for sample classification. Drug Test Anal 2020; 12:836-845. [DOI: 10.1002/dta.2775] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 01/17/2020] [Accepted: 01/28/2020] [Indexed: 01/08/2023]
Affiliation(s)
- Gabriel L. Streun
- Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic MedicineUniversity of Zurich Zurich Switzerland
| | - Marco P. Elmiger
- Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic MedicineUniversity of Zurich Zurich Switzerland
| | - Akos Dobay
- Department of Forensic Genetics, Zurich Institute of Forensic MedicineUniversity of Zurich Zurich Switzerland
- Department of Forensic Imaging/Virtopsy, Zurich Institute of Forensic MedicineUniversity of Zurich Zurich Switzerland
| | - Lars Ebert
- Department of Forensic Imaging/Virtopsy, Zurich Institute of Forensic MedicineUniversity of Zurich Zurich Switzerland
| | - Thomas Kraemer
- Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic MedicineUniversity of Zurich Zurich Switzerland
| |
Collapse
|
26
|
Beccaria M, Cabooter D. Current developments in LC-MS for pharmaceutical analysis. Analyst 2020; 145:1129-1157. [DOI: 10.1039/c9an02145k] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Liquid chromatography (LC) based techniques in combination with mass spectrometry (MS) detection have had a large impact on the development of new pharmaceuticals in the past decades.
Collapse
Affiliation(s)
- Marco Beccaria
- KU Leuven
- Department for Pharmaceutical and Pharmacological Sciences
- Pharmaceutical Analysis
- Leuven
- Belgium
| | - Deirdre Cabooter
- KU Leuven
- Department for Pharmaceutical and Pharmacological Sciences
- Pharmaceutical Analysis
- Leuven
- Belgium
| |
Collapse
|
27
|
Jaiswal D, Wangikar PP. SWATH: A Data-Independent Tandem Mass Spectrometry Method to Quantify 13C Enrichment in Cellular Metabolites and Fragments. Methods Mol Biol 2020; 2088:189-204. [PMID: 31893375 DOI: 10.1007/978-1-0716-0159-4_9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Recently, the sequential windowed acquisition of all theoretical fragment ion mass spectra (SWATH) method coupled with liquid chromatography has been demonstrated for the quantification of isotopic 13C enrichment in a large number of cellular metabolites and fragments. SWATH, a data-independent acquisition (DIA) method, alleviates the need for data deconvolution and shows greater accuracy in the quantification of low abundance isotopologs of fragments thereby resulting in a lower systematic error. Here we provide a detailed protocol for the design of Q1 mass isolation windows and the post-acquisition data analysis with emphasis on the untargeted nature of SWATH.
Collapse
Affiliation(s)
- Damini Jaiswal
- Department of Chemical Engineering, Indian Institute of Technology Bombay, Mumbai, India
| | - Pramod P Wangikar
- Department of Chemical Engineering, Indian Institute of Technology Bombay, Mumbai, India.
- DBT-PAN IIT Centre for Bioenergy, Indian Institute of Technology Bombay, Mumbai, India.
- Wadhwani Research Centre for Bioengineering, Indian Institute of Technology Bombay, Mumbai, India.
| |
Collapse
|
28
|
Azimi A, Yang P, Ali M, Howard V, Mann GJ, Kaufman KL, Fernandez-Penas P. Data Independent Acquisition Proteomic Analysis Can Discriminate between Actinic Keratosis, Bowen’s Disease, and Cutaneous Squamous Cell Carcinoma. J Invest Dermatol 2020; 140:212-222.e11. [DOI: 10.1016/j.jid.2019.06.128] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 05/28/2019] [Accepted: 06/11/2019] [Indexed: 12/19/2022]
|
29
|
Liu Y, Romijn EP, Verniest G, Laukens K, De Vijlder T. Mass spectrometry-based structure elucidation of small molecule impurities and degradation products in pharmaceutical development. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115686] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
30
|
Krotulski AJ, Mohr ALA, Logan BK. Emerging Synthetic Cannabinoids: Development and Validation of a Novel Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Assay for Real-Time Detection. J Anal Toxicol 2019; 44:207-217. [DOI: 10.1093/jat/bkz084] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 06/25/2019] [Accepted: 07/28/2019] [Indexed: 01/31/2023] Open
Abstract
Abstract
Synthetic cannabinoids pose significant threats to public health and safety, as their implications in overdose and adverse events continue to arise in United States and around the world. Synthetic cannabinoids have seen several generations of chemically diverse structural elements, impacting potency and effects. These factors create new analytical challenges for forensic laboratories. This report describes an efficient liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) assay for the identification of synthetic cannabinoid parent compounds and metabolites, including real-time identification of emergent compounds, using a SCIEX TripleTOF® 5600+ with non-targeted SWATH® acquisition. Method validation evaluated precision/accuracy, limits of detection, interferences, processed sample stability and carryover, for which 19 parent compounds and 19 metabolites were tested. To demonstrate feasibility, de-identified blood sample extracts were acquired from a large forensic toxicology laboratory and analyzed using the validated LC-QTOF-MS assay. In mid-2018, 200 blood extracts were analyzed, demonstrating a 19% positivity rate with > 94% agreement rate with original testing. In addition, three newly discovered synthetic cannabinoids were identified, including 5F-MDMB-PICA, 4-cyano CUMYL-BUTINACA and 5F-EDMB-PINACA. These synthetic cannabinoids were previously unreported in forensic toxicology casework in the United States. 5F-MDMB-PICA has become the most prevalent synthetic cannabinoid in United States, as of early 2019. These results demonstrate the effectiveness of this assay and workflow in the identification and characterization of synthetic cannabinoids, as well as the usefulness of sample-mining using non-targeted mass acquisition by LC-QTOF-MS for the discovery of NPS. High resolution mass spectrometry should be considered when developing new or novel assays for synthetic cannabinoids.
Collapse
Affiliation(s)
- Alex J Krotulski
- Center for Forensic Science Research and Education (CFSRE), Fredric Rieders Family Foundation, 2300 Stratford Ave, Willow Grove, PA, USA
| | - Amanda L A Mohr
- Center for Forensic Science Research and Education (CFSRE), Fredric Rieders Family Foundation, 2300 Stratford Ave, Willow Grove, PA, USA
| | - Barry K Logan
- Center for Forensic Science Research and Education (CFSRE), Fredric Rieders Family Foundation, 2300 Stratford Ave, Willow Grove, PA, USA
- NMS Labs, 200 Welsh Rd, Horsham, PA, USA
| |
Collapse
|
31
|
|
32
|
Krotulski AJ, Varnum SJ, Logan BK. Sample Mining and Data Mining: Combined Real‐Time and Retrospective Approaches for the Identification of Emerging Novel Psychoactive Substances. J Forensic Sci 2019; 65:550-562. [DOI: 10.1111/1556-4029.14184] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 08/13/2019] [Accepted: 08/14/2019] [Indexed: 11/29/2022]
Affiliation(s)
- Alex J. Krotulski
- Department of Chemistry Temple University 1801 North Broad Street Philadelphia PA
- Center for Forensic Science Research and Education Fredric Rieders Family Foundation 2300 Stratford Ave Willow Grove PA
| | - Susan Jansen Varnum
- Department of Chemistry Temple University 1801 North Broad Street Philadelphia PA
| | - Barry K. Logan
- Center for Forensic Science Research and Education Fredric Rieders Family Foundation 2300 Stratford Ave Willow Grove PA
- NMS Labs 200 Welsh Rd Horsham PA
| |
Collapse
|
33
|
Guyader ME, Warren LD, Green E, Butt C, Ivosev G, Kiesling RL, Schoenfuss HL, Higgins CP. Prioritizing potential endocrine active high resolution mass spectrometry (HRMS) features in Minnesota lakewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 670:814-825. [PMID: 30921715 DOI: 10.1016/j.scitotenv.2019.02.448] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 02/08/2019] [Accepted: 02/28/2019] [Indexed: 06/09/2023]
Abstract
Liquid chromatography high-resolution mass spectrometry (LC-HRMS) shows great potential for expanding our understanding of relevant unknown chemical components present within complex environmental mixtures. This study identified potentially endocrine active components within Minnesota lakewater by prioritizing LC-HRMS features uniquely present at sunfish spawning habitats where male fish showed signs of estrogen agonism. Porewater samples from four locations within the same lake were analyzed using liquid chromatography quadrupole time of flight mass spectrometry (LC-QToF/MS) with positive (ESI+) and negative (ESI-) electrospray ionization. Plasma vitellogenin concentrations of captured male sunfish was used to designate sites as either endocrine active (ACT; 2 sites) or reference (REF; 2 sites). Assuming unique chemical presence at active sites contributed to endocrine activity, features at significantly higher intensities (p-value < 0.05, t-value > t-critical, log-fold change > 0.1; equal variance t-test of log2 transformed data) in ACT sites were then compiled into a suspect search list for feature identification. Adducts and isotopes of prioritized features were deprioritized using pattern recognizing algorithms using mass, retention time, and intensity. Feature identities were reported according to established confidence metrics using spectral libraries and elemental composition algorithms. This LC-HRMS approach identified a number of features omitted by targeted analysis with higher relative abundances in ACT sites, including plant essential oils, fatty acids, and mycotoxins. Multivariate analysis determined whether features were either present at both sites (AB) or unique to individual ACT sites (A or B). Detection frequency across datasets indicated bias in feature prioritization influenced by the chosen sampling method and sample acquisition mode. The majority of features prioritized by this workflow remain tentatively identified or unidentified masses of interest, reflective of current limitations in shared spectral libraries for soft ionization analyses. Strategies similar to this workflow have the potential to reduce bias in database-driven toxicological prioritization frameworks.
Collapse
|
34
|
Klingberg J, Cawley A, Shimmon R, Fu S. Collision-Induced Dissociation Studies of Synthetic Opioids for Non-targeted Analysis. Front Chem 2019; 7:331. [PMID: 31139620 PMCID: PMC6527801 DOI: 10.3389/fchem.2019.00331] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 04/24/2019] [Indexed: 01/30/2023] Open
Abstract
The continual introduction of a large number of new psychoactive substances, along with the large turnover of these substances, necessitates the development of non-targeted detection strategies to keep pace with the ever-changing drug market. The production of certified reference materials often lags behind the introduction of new substances to the market, therefore these detection strategies need to be able to function without relying on reference materials or library spectra. Synthetic opioids have recently emerged as a drug class of particular concern due to the health issues caused by their incredibly high potency. A common method which has been used for non-targeted analysis in the past involves the identification of common product ions formed as a result of the fragmentation of the parent molecule. These common fragments can then potentially be used as markers to indicate the presence of a particular class of compounds within a sample. In this study, standards of a number of different synthetic opioids, including 14 fentanyl derivatives, 7 AH series opioids, 4 U series opioids, 4 W series opioids and MT-45, were subjected to collision-induced dissociation studies to determine how the compounds fragment. The spectra obtained from these studies included a number of diagnostic fragments common to the different opioid classes that, when used in combination, show potential for use as class predictors. By using simple data processing techniques, such as extracted ion chromatograms, these diagnostic product ions identified can be applied to a non-targeted screening workflow.
Collapse
Affiliation(s)
- Joshua Klingberg
- Centre for Forensic Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Adam Cawley
- Australian Racing Forensic Laboratory, Racing NSW, Sydney, NSW, Australia
| | - Ronald Shimmon
- Centre for Forensic Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Shanlin Fu
- Centre for Forensic Science, University of Technology Sydney, Ultimo, NSW, Australia
| |
Collapse
|
35
|
Whitman JD, Lynch KL. Optimization and Comparison of Information-Dependent Acquisition (IDA) to Sequential Window Acquisition of All Theoretical Fragment Ion Spectra (SWATH) for High-Resolution Mass Spectrometry in Clinical Toxicology. Clin Chem 2019; 65:862-870. [PMID: 30996055 DOI: 10.1373/clinchem.2018.300756] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 03/22/2019] [Indexed: 11/06/2022]
Abstract
BACKGROUND Untargeted data acquisition on high-resolution mass spectrometers (HRMSs) has been used in clinical toxicology for screening and identifying unknown compounds in patient samples. A common modality for untargeted HRMS data acquisition is information-dependent acquisition (IDA), which analyzes the most abundant small molecules within an acquisition cycle. This process can potentially lead to false negatives of clinically relevant compounds at low concentrations. Sequential window acquisition of all theoretical fragment ion spectra (SWATH) has emerged as a method of unbiased, untargeted HRMS data acquisition in which no spectral data are lost. SWATH has yet to be optimized and assessed for use in clinical toxicology. METHOD We developed a variable-window SWATH method (vSWATH) and compared it to IDA by limit of detection studies in drug-supplemented urine (81 compounds) and against a retrospective cohort of 50 clinical urine samples characterized by LC-MS/MS. RESULTS vSWATH had a lower limit of detection than IDA for 33 (41%) drugs and metabolites added into urine samples. Both IDA and vSWATH were equivalent in discovering compounds from clinical urine samples and confirmed 26 additional compounds not previously discovered by targeted LC-MS/MS. Lastly, the unbiased acquisition of spectra in vSWATH allowed for identification of 5 low-abundance compounds missed by IDA. CONCLUSIONS This vSWATH method for clinical toxicology demonstrated equivalent analytical sensitivity and specificity for untargeted drug screening and identification in urine samples. vSWATH provided the additional benefit of collecting all tandem mass spectrometry spectra in a sample, which could be useful in discovering low-abundance compounds not discovered by IDA.
Collapse
Affiliation(s)
- Jeffrey D Whitman
- Department of Laboratory Medicine, University of California San Francisco, San Francisco, CA.
| | - Kara L Lynch
- Department of Laboratory Medicine, University of California San Francisco, San Francisco, CA
| |
Collapse
|
36
|
Zubaidi FA, Choo YM, Tan GH, Myron P, Cornelia CS. High-throughput flow injection analysis-MRM3 (FIA-MRM3) spectrometry for alternative fast screening of the isomeric methamphetamine and phentermine in blood for forensic toxicology cases in Malaysia. TOXICOLOGY RESEARCH AND APPLICATION 2019. [DOI: 10.1177/2397847319831368] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
- Fathiah A Zubaidi
- Department of Chemistry, University of Malaya, Kuala Lumpur, Malaysia
- Department of Chemistry Malaysia, Ministry of Science, Technology and Innovation (MOSTI), Petaling Jaya, Malaysia
| | - Yeun-Mun Choo
- Department of Chemistry, University of Malaya, Kuala Lumpur, Malaysia
| | - Guan-Huat Tan
- Department of Chemistry, University of Malaya, Kuala Lumpur, Malaysia
| | - P Myron
- Department of Chemistry Malaysia, Ministry of Science, Technology and Innovation (MOSTI), Petaling Jaya, Malaysia
| | - CS Cornelia
- Department of Chemistry Malaysia, Ministry of Science, Technology and Innovation (MOSTI), Petaling Jaya, Malaysia
| |
Collapse
|
37
|
Liquid chromatography-high resolution mass spectrometry for broad-spectrum drug screening of dried blood spot as microsampling procedure. Anal Chim Acta 2019; 1063:110-116. [PMID: 30967174 DOI: 10.1016/j.aca.2019.02.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Revised: 01/28/2019] [Accepted: 02/04/2019] [Indexed: 12/31/2022]
Abstract
BACKGROUND Hyphenation of liquid chromatography (LC) with high-resolution mass spectrometry (HRMS) offers the potential to develop broad-spectrum screening procedures from low volumes of biological matrices. In parallel, dried blood spot (DBS) has become a valuable tool in the bioanalysis landscape to overcome conventional blood collection issues. Herein, we demonstrated the applicability of DBS as micro-sampling procedure for broad-spectrum toxicological screening. METHODS A method was developed on a HRMS system in data dependant acquisition (DDA) mode using an extensive inclusion list to promote collection of relevant data. 104 real toxicology cases were analysed, and the results were cross-validated with one published and one commercial screening procedures. Quantitative MRM analyses were also performed on identified substances on a triple quadrupole instrument as a complementary confirmation procedure. RESULTS The method showed limits of identification (LOIs) in appropriateness with therapeutic ranges for all the classes of interest. Applying the three screening approaches on 104 real cases, 271 identifications were performed including 14 and 6 classes of prescribed and illicit drugs, respectively. Among the detected substances, 23% were only detected by the proposed method. Based on confirmatory analyses, we demonstrated that the use of blood micro-samples did not impair the sensitivity allowing more identifications in the low concentration ranges. CONCLUSION A LC-HRMS assay was successfully developed for toxicological screening of blood microsamples demonstrating a high identification power at low concentration ranges. The validation procedure and the analysis of real cases demonstrated the potential of this assay by supplementing screening approaches of reference.
Collapse
|
38
|
Reinstadler V, Lierheimer S, Boettcher M, Oberacher H. A validated workflow for drug detection in oral fluid by non-targeted liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 2019; 411:867-876. [PMID: 30519959 PMCID: PMC6338695 DOI: 10.1007/s00216-018-1504-x] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 11/05/2018] [Accepted: 11/19/2018] [Indexed: 12/16/2022]
Abstract
Oral fluid is recognized as an important specimen for drug testing. Common applications are monitoring in substance abuse treatment programs, therapeutic drug monitoring, pain management, workplace drug testing, clinical toxicology, and driving under the influence of drugs (DRUID). In this study, we demonstrate that non-targeted LC-MS/MS with subsequent compound identification by tandem mass spectral library search is a valuable tool for comprehensive detection and confirmation of drugs in oral fluid samples. The workflow developed involves solid-phase extraction and chromatographic separation on reversed phase materials. Mass spectrometric detection is accomplished on a quadrupole-quadrupole-time-of-flight instrument operated with data-dependent acquisition control. The workflow was optimized for 500 μl of neat oral fluid collected with the Greiner Bio-One saliva collection system. The fitness of the developed method was tested and proven by analyzing blank and spiked samples as well as 59 authentic patient samples. We could demonstrate that compounds with logP values in the range 0.5-5.5 are efficiently detected at low nanograms per milliliter concentrations. The true positive and true negative rates of automated library search were equal or close to 100%. The beauty of the non-targeted LC-MS/MS approach is the ability to detect compounds hardly included in routinely applied targeted assays, and this was demonstrated by detecting the synthetic opioid U-47700 in two patient samples. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Vera Reinstadler
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Muellerstr. 44, 6020, Innsbruck, Austria
| | - Stefan Lierheimer
- MVZ Labor Dessau GmbH, Bauhüttenstr. 6, 06847, Dessau-Roßlau, Germany
| | - Michael Boettcher
- MVZ Labor Dessau GmbH, Bauhüttenstr. 6, 06847, Dessau-Roßlau, Germany
| | - Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Muellerstr. 44, 6020, Innsbruck, Austria.
| |
Collapse
|
39
|
Oberacher H, Reinstadler V, Kreidl M, Stravs MA, Hollender J, Schymanski EL. Annotating Nontargeted LC-HRMS/MS Data with Two Complementary Tandem Mass Spectral Libraries. Metabolites 2018; 9:metabo9010003. [PMID: 30583579 PMCID: PMC6359582 DOI: 10.3390/metabo9010003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 12/17/2018] [Accepted: 12/21/2018] [Indexed: 12/15/2022] Open
Abstract
Tandem mass spectral databases are indispensable for fast and reliable compound identification in nontargeted analysis with liquid chromatography–high resolution tandem mass spectrometry (LC-HRMS/MS), which is applied to a wide range of scientific fields. While many articles now review and compare spectral libraries, in this manuscript we investigate two high-quality and specialized collections from our respective institutes, recorded on different instruments (quadrupole time-of-flight or QqTOF vs. Orbitrap). The optimal range of collision energies for spectral comparison was evaluated using 233 overlapping compounds between the two libraries, revealing that spectra in the range of CE 20–50 eV on the QqTOF and 30–60 nominal collision energy units on the Orbitrap provided optimal matching results for these libraries. Applications to complex samples from the respective institutes revealed that the libraries, combined with a simple data mining approach to retrieve all spectra with precursor and fragment information, could confirm many validated target identifications and yield several new Level 2a (spectral match) identifications. While the results presented are not surprising in many ways, this article adds new results to the debate on the comparability of Orbitrap and QqTOF data and the application of spectral libraries to yield rapid and high-confidence tentative identifications in complex human and environmental samples.
Collapse
Affiliation(s)
- Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, 6020 Innsbruck, Austria.
| | - Vera Reinstadler
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, 6020 Innsbruck, Austria.
| | - Marco Kreidl
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, 6020 Innsbruck, Austria.
| | - Michael A Stravs
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland.
| | - Juliane Hollender
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland.
- Institute of Biogeochemistry and Pollutant Dynamics, ETH Zurich, 8092 Zurich, Switzerland.
| | - Emma L Schymanski
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland.
- Luxembourg Centre for Systems Biomedicine (LCSB), University of Luxembourg, 4367 Belvaux, Luxembourg.
| |
Collapse
|
40
|
Li J, Levitan B, Gomez-Jimenez S, Kültz D. Development of a Gill Assay Library for Ecological Proteomics of Threespine Sticklebacks ( Gasterosteus aculeatus). Mol Cell Proteomics 2018; 17:2146-2163. [PMID: 30093419 PMCID: PMC6210217 DOI: 10.1074/mcp.ra118.000973] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 08/07/2018] [Indexed: 12/31/2022] Open
Abstract
A data-independent acquisition (DIA) assay library for quantitative analyses of proteome dynamics has been developed for gills of threespine sticklebacks (Gasterosteus aculeatus). A raw spectral library was generated by data-dependent acquisition (DDA) and annotation of tryptic peptides to MSMS spectra and protein database identifiers. The assay library was constructed from the raw spectral library by removal of low-quality, ambiguous, and low-signal peptides. Only unique proteins represented by at least two peptides are included in the assay library, which consists of 1506 proteins, 5074 peptides, 5104 precursors, and 25,322 transitions. This assay library was used with DIA data to identify biochemical differences in gill proteomes of four populations representing different eco- and morpho-types of threespine sticklebacks. The assay library revealed unique and reproducible proteome signatures. Warm-adapted, low-plated, brackish-water fish from Laguna de la Bocana del Rosario (Mexico) show elevated HSP47, extracellular matrix, and innate immunity proteins whereas several immunoglobulins, interferon-induced proteins, ubiquitins, proteolytic enzymes, and nucleic acid remodeling proteins are reduced. Fully-plated, brackish-water fish from Westchester Lagoon (Alaska) display elevated ion regulation, GTPase signaling, and contractile cytoskeleton proteins, altered abundances of many ribosomal, calcium signaling and immunity proteins, and depleted transcriptional regulators and metabolic enzymes. Low-plated freshwater fish from Lake Solano (California) have elevated inflammasomes and proteolytic proteins whereas several iron containing and ion regulatory proteins are reduced. Gills of fully-plated, marine fish from Bodega Harbor (California) have elevated oxidative metabolism enzymes and reduced transglutaminase 2, collagens, and clathrin heavy chains. These distinct proteome signatures represent targets for testing ecological and evolutionary influences on molecular mechanisms of gill function in threespine sticklebacks. Furthermore, the gill assay library represents a model for other tissues and paves the way for accurate and reproducible network analyses of environmental context-dependent proteome dynamics in complex organisms.
Collapse
Affiliation(s)
- Johnathon Li
- From the ‡Department of Animal Sciences, University of California Davis, Meyer Hall, One Shields Ave., Davis, CA 95616
| | - Bryn Levitan
- From the ‡Department of Animal Sciences, University of California Davis, Meyer Hall, One Shields Ave., Davis, CA 95616
| | - Silvia Gomez-Jimenez
- §Centro de Investigación en Alimentación y Desarrollo, Carretera a la Victoria Km. 0.6, Apartado, Hermosillo, Sonora, México C.P. 83000
| | - Dietmar Kültz
- From the ‡Department of Animal Sciences, University of California Davis, Meyer Hall, One Shields Ave., Davis, CA 95616;
- ¶Coastal Marine Sciences Institute, University of California, Davis
| |
Collapse
|
41
|
Partridge E, Trobbiani S, Stockham P, Scott T, Kostakis C. A Validated Method for the Screening of 320 Forensically Significant Compounds in Blood by LC/QTOF, with Simultaneous Quantification of Selected Compounds. J Anal Toxicol 2018; 42:220-231. [PMID: 29329431 DOI: 10.1093/jat/bkx108] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Accepted: 12/08/2017] [Indexed: 11/14/2022] Open
Abstract
A broad drug screening method for toxicologically significant drugs and metabolites in whole blood using liquid chromatography time-of-flight mass spectrometry (LC/QTOF) was developed and comprehensively validated. The method qualitatively screens for 320 compounds while simultaneously quantifying 39. Compounds were extracted from the blood using alkaline liquid/liquid extraction and chromatographic separation was achieved in 12 min. The QTOF was operated using positive mode electrospray ionization using data dependent acquisition. Qualitative validation was performed for all 320 compounds, and included selectivity, recovery, limit of detection, matrix effects, carryover and extract stability. The limits of detection were in the low to sub ng/mL range for the majority of compounds. Full quantitative validation was performed for 39 compounds and accuracy and precision were within 15 and 18%, respectively. The qualitative data processing method uses an in-house retention time, accurate mass and MSMS spectral database, which can be easily updated with new compounds of interest as they emerge onto the market, without affecting method performance. The use of a non-targeted data acquisition method coupled with targeted data processing has proven to be a highly versatile, efficient and robust approach to screening, well suited to meet the needs of the modern toxicology laboratory involved in systematic toxicological analysis.
Collapse
Affiliation(s)
- Emma Partridge
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5001, Australia.,Flinders University of South Australia, Sturt Road, Bedford Park, South Australia, 5042, Australia
| | - Stephen Trobbiani
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5001, Australia
| | - Peter Stockham
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5001, Australia.,Flinders University of South Australia, Sturt Road, Bedford Park, South Australia, 5042, Australia
| | - Timothy Scott
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5001, Australia.,Flinders University of South Australia, Sturt Road, Bedford Park, South Australia, 5042, Australia
| | - Chris Kostakis
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5001, Australia
| |
Collapse
|
42
|
Wong JW, Wang J, Chow W, Carlson R, Jia Z, Zhang K, Hayward DG, Chang JS. Perspectives on Liquid Chromatography-High-Resolution Mass Spectrometry for Pesticide Screening in Foods. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2018; 66:9573-9581. [PMID: 30169025 DOI: 10.1021/acs.jafc.8b03468] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
This perspective discusses the use of liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) for multiresidue analysis of pesticides in foods and agricultural commodities. HRMS has the important distinction and advantage of mass-resolving power and, therefore, requires different concepts, experiments, and guidance for screening, identification, and quantitation of pesticides in complex food matrices over triple quadrupole mass spectrometry. HRMS approaches for pesticide screening, including full-scan experiments in conjunction with tandem mass spectrometry (MS/MS) experiments, are described. This approach results in the generation of chromatographic retention times and high-resolution mass spectra with accurate mass measurements that can be used to create compound databases. New data processing tools can create an efficient and optimized screening approach that can speed the analysis and identification of compounds, reduce the need for chemical standards, and harmonize pesticide analytical procedures.
Collapse
Affiliation(s)
- Jon W Wong
- Center for Food Safety and Applied Nutrition , United States Food and Drug Administration , 5001 Campus Drive , College Park , Maryland 20740 , United States
| | - Jian Wang
- Calgary Laboratory , Canadian Food Inspection Agency , 3650 36th Street Northwest , Calgary , Alberta T2L 2L1 , Canada
| | - Willis Chow
- Calgary Laboratory , Canadian Food Inspection Agency , 3650 36th Street Northwest , Calgary , Alberta T2L 2L1 , Canada
| | - Roland Carlson
- Center for Analytical Chemistry , California Department of Food and Agriculture , 3292 Meadowview Road , Sacramento , California 95832 , United States
| | - Zhengwei Jia
- Shanghai Institute for Food and Drug Control (SIFDC) , 1500 Zhangheng Road , Shanghai 210203 , People's Republic of China
| | - Kai Zhang
- Center for Food Safety and Applied Nutrition , United States Food and Drug Administration , 5001 Campus Drive , College Park , Maryland 20740 , United States
| | - Douglas G Hayward
- Center for Food Safety and Applied Nutrition , United States Food and Drug Administration , 5001 Campus Drive , College Park , Maryland 20740 , United States
| | - James S Chang
- Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States
| |
Collapse
|
43
|
Wang L, Su B, Zeng Z, Li C, Zhao X, Lv W, Xuan Q, Ouyang Y, Zhou L, Yin P, Peng X, Lu X, Lin X, Xu G. Ion-Pair Selection Method for Pseudotargeted Metabolomics Based on SWATH MS Acquisition and Its Application in Differential Metabolite Discovery of Type 2 Diabetes. Anal Chem 2018; 90:11401-11408. [PMID: 30148611 DOI: 10.1021/acs.analchem.8b02377] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The pseudotargeted metabolomics method integrates advantages of nontargeted and targeted analysis because it can acquire data of metabolites in the multireaction monitoring (MRM) mode of mass spectrometry (MS) without needing standards. The key is the ion-pair information collection from samples to be analyzed. It is well-known that sequential windowed acquisition of all theoretical Fragment ion (SWATH) MS mode can acquire MS2 information to a maximum extent. To expediently acquire as many ion-pairs as possible with optimal collision energy (CE), an ion-pair selection approach based on SWATH MS acquisition with variable isolation windows was developed in this study. Initially, nontargeted acquisition of all metabolites information in plasma Standard Reference Material (SRM 1950) was performed by ultra high-performance liquid chromatography (UHPLC)-quadrupole time-of-flight (Q-TOF) MS platform with three CEs. With the help of software tool, the ion-pairs of unique metabolites were gained. Then they were validated in scheduled MRM coupled with UHPLC. After removing false positive, the ion-pairs with an optimal CE was integrated. A total of 1373 unique metabolite ion-pairs were obtained at positive ion mode. And repeatability of the established pseudotargeted approach was evaluated by intraday and interday precision. The results demonstrated the method was stable, reliable, and suitable for metabolomics study. As an application example, alterations of serum metabolites in Type 2 diabetes were investigated by using the established method. This work provides a pseudotargeted ion-pair selection method based on SWATH MS acquisition with the characters of increased metabolite coverage, suitable CE, and convenient processing.
Collapse
Affiliation(s)
- Lichao Wang
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,State Key Laboratory of Fine Chemicals , Dalian University of Technology , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Benzhe Su
- School of Computer Science & Technology , Dalian University of Technology , Dalian 116024 , P. R. China
| | - Zhongda Zeng
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China
| | - Chao Li
- School of Computer Science & Technology , Dalian University of Technology , Dalian 116024 , P. R. China
| | - Xinjie Zhao
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Wangjie Lv
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Qiuhui Xuan
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Yang Ouyang
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Lina Zhou
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Peiyuan Yin
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Xiaojun Peng
- State Key Laboratory of Fine Chemicals , Dalian University of Technology , Dalian 116023 , P. R. China
| | - Xin Lu
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| | - Xiaohui Lin
- School of Computer Science & Technology , Dalian University of Technology , Dalian 116024 , P. R. China
| | - Guowang Xu
- CAS Key Laboratory of Separation Science for Analytical Chemistry , Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road , Dalian 116023 , P. R. China.,University of Chinese Academy of Sciences , Beijing 100049 , P. R. China
| |
Collapse
|
44
|
Schlotterbeck J, Chatterjee M, Gawaz M, Lämmerhofer M. Comprehensive MS/MS profiling by UHPLC-ESI-QTOF-MS/MS using SWATH data-independent acquisition for the study of platelet lipidomes in coronary artery disease. Anal Chim Acta 2018; 1046:1-15. [PMID: 30482286 DOI: 10.1016/j.aca.2018.08.060] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Revised: 08/29/2018] [Accepted: 08/30/2018] [Indexed: 01/13/2023]
Abstract
A non-targeted lipidomics workflow based on C8 core-shell particle ultra high-performance liquid chromatography (UHPLC) hyphenated to ESI-QTOF-MS in data-independent acquisition (DIA) mode with sequential window acquisition of all theoretical fragment ion spectra (SWATH) was developed and applied to differential platelet lipidomics profiling of cardiovascular disease patients (stable angina pectoris (n = 10), ST-elevated myocardial infarction (n = 13)) against healthy controls (n = 10). DIA with SWATH generates comprehensive MS and MS/MS data throughout the entire chromatograms and all study samples. Hence, chromatograms can be extracted based on precursors or fragments which provided some benefits in terms of assay specificity in some cases. SWATH acquisition offers flexible experimental design with variable Q1 isolation windows. Liquid chromatography as well as SWATH settings were optimized to cover the lipidome of human platelets. The flexibility of the SWATH experiment design was utilized to implement target SWATH windows with narrow 5 Da Q1 precursor ion selection width (multiple reaction monitoring (MRM)-like SWATH windows) for the detection of low abundant oxidized phospholipids. Data processing was performed with MS-DIAL, and its feasibilities and caveats are discussed by illustrative examples. Thereby, identification of lipids is still a bottleneck in non-targeted lipidomics workflow. MS-DIAL, however, offers automatic identification via spectral matching using an in silico library. In total 1971 molecular features were detected cross the samples of which 611 were identified (total score >70%). The quality of the acquired data was validated with embedded quality control samples (n = 11). 80.3% of all features detected in the QC samples showed a coefficient of variation of below 30%. Multivariate statistics were used to visualize differences in the lipidome of distinct sample groups at a false discovery rate of 5%.
Collapse
Affiliation(s)
- Jörg Schlotterbeck
- University of Tübingen, Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, Auf der Morgenstelle 8, 72076, Tübingen, Germany
| | - Madhumita Chatterjee
- Department of Cardiology and Cardiovascular Medicine, University Hospital Tübingen, Otfried-Müller-Strasse 10, 72076, Tübingen, Germany
| | - Meinrad Gawaz
- Department of Cardiology and Cardiovascular Medicine, University Hospital Tübingen, Otfried-Müller-Strasse 10, 72076, Tübingen, Germany
| | - Michael Lämmerhofer
- University of Tübingen, Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, Auf der Morgenstelle 8, 72076, Tübingen, Germany.
| |
Collapse
|
45
|
Drotleff B, Hallschmid M, Lämmerhofer M. Quantification of steroid hormones in plasma using a surrogate calibrant approach and UHPLC-ESI-QTOF-MS/MS with SWATH-acquisition combined with untargeted profiling. Anal Chim Acta 2018; 1022:70-80. [DOI: 10.1016/j.aca.2018.03.040] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 03/16/2018] [Accepted: 03/20/2018] [Indexed: 11/16/2022]
|
46
|
Fully-automated systems and the need for global approaches should exhort clinical labs to reinvent routine MS analysis? Bioanalysis 2018; 10:1129-1141. [DOI: 10.4155/bio-2018-0074] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Today, many LC–high-resolution MS instruments have become affordable, easy-to-use, sensitive and quantitative. Meanwhile, there is an increased need for more comprehensive approaches. However, omics analyses are still restricted to specialists whereas, in hospitals, routine analyses are targeted and quantitative and represent the main and heavy tasks. But the availability of fully automated LC–MS instruments that can handle independently from sample extraction to result reporting, as well as the increasing biomedical interest for global approaches, clinical analytical workflow should be reorganized. Bioanalysts are now in the position to develop/implement clinical metabolomics or proteomics as routine analyses. In this article, this coming evolution and the reasons to implement global/omics determinations as routine analysis, is described.
Collapse
|
47
|
Kind T, Tsugawa H, Cajka T, Ma Y, Lai Z, Mehta SS, Wohlgemuth G, Barupal DK, Showalter MR, Arita M, Fiehn O. Identification of small molecules using accurate mass MS/MS search. MASS SPECTROMETRY REVIEWS 2018; 37:513-532. [PMID: 28436590 PMCID: PMC8106966 DOI: 10.1002/mas.21535] [Citation(s) in RCA: 287] [Impact Index Per Article: 41.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 03/17/2017] [Accepted: 03/18/2017] [Indexed: 05/03/2023]
Abstract
Tandem mass spectral library search (MS/MS) is the fastest way to correctly annotate MS/MS spectra from screening small molecules in fields such as environmental analysis, drug screening, lipid analysis, and metabolomics. The confidence in MS/MS-based annotation of chemical structures is impacted by instrumental settings and requirements, data acquisition modes including data-dependent and data-independent methods, library scoring algorithms, as well as post-curation steps. We critically discuss parameters that influence search results, such as mass accuracy, precursor ion isolation width, intensity thresholds, centroiding algorithms, and acquisition speed. A range of publicly and commercially available MS/MS databases such as NIST, MassBank, MoNA, LipidBlast, Wiley MSforID, and METLIN are surveyed. In addition, software tools including NIST MS Search, MS-DIAL, Mass Frontier, SmileMS, Mass++, and XCMS2 to perform fast MS/MS search are discussed. MS/MS scoring algorithms and challenges during compound annotation are reviewed. Advanced methods such as the in silico generation of tandem mass spectra using quantum chemistry and machine learning methods are covered. Community efforts for curation and sharing of tandem mass spectra that will allow for faster distribution of scientific discoveries are discussed.
Collapse
Affiliation(s)
- Tobias Kind
- Genome Center, Metabolomics, UC Davis, Davis, California
| | - Hiroshi Tsugawa
- RIKEN Center for Sustainable Resource Science, Yokohama, Kanagawa, Japan
| | - Tomas Cajka
- Genome Center, Metabolomics, UC Davis, Davis, California
| | - Yan Ma
- National Institute of Biological Sciences, Beijing, People’s Republic of China
| | - Zijuan Lai
- Genome Center, Metabolomics, UC Davis, Davis, California
| | | | | | | | | | - Masanori Arita
- RIKEN Center for Sustainable Resource Science, Yokohama, Kanagawa, Japan
| | - Oliver Fiehn
- Genome Center, Metabolomics, UC Davis, Davis, California
- Faculty of Sciences, Department of Biochemistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
48
|
Jaiswal D, Prasannan CB, Hendry JI, Wangikar PP. SWATH Tandem Mass Spectrometry Workflow for Quantification of Mass Isotopologue Distribution of Intracellular Metabolites and Fragments Labeled with Isotopic 13C Carbon. Anal Chem 2018; 90:6486-6493. [PMID: 29712418 DOI: 10.1021/acs.analchem.7b05329] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Accurate quantification of mass isotopologue distribution (MID) of metabolites is a prerequisite for 13C-metabolic flux analysis. Currently used mass spectrometric (MS) techniques based on multiple reaction monitoring (MRM) place limitations on the number of MIDs that can be analyzed in a single run. Moreover, the deconvolution step results in amplification of error. Here, we demonstrate that SWATH MS/MS, a data independent acquisition (DIA) technique allows quantification of a large number of precursor and product MIDs in a single run. SWATH sequentially fragments all precursor ions in stacked mass isolation windows. Co-fragmentation of all precursor isotopologues in a single SWATH window yields higher sensitivity enabling quantification of MIDs of fragments with low abundance and lower systematic and random errors. We quantify the MIDs of 53 precursor and product ions corresponding to 19 intracellular metabolites from a dynamic 13C-labeling of a model cyanobacterium, Synechococcus sp. PCC 7002. The use of product MIDs resulted in an improved precision of many measured fluxes compared to when only precursor MIDs were used for flux analysis. The approach is truly untargeted and allows additional metabolites to be quantified from the same data.
Collapse
Affiliation(s)
- Damini Jaiswal
- Department of Chemical Engineering , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India
| | - Charulata B Prasannan
- Department of Chemical Engineering , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India.,DBT-Pan IIT Center for Bioenergy , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India
| | - John I Hendry
- Department of Chemical Engineering , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India
| | - Pramod P Wangikar
- Department of Chemical Engineering , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India.,DBT-Pan IIT Center for Bioenergy , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India.,Wadhwani Research Center for Bioengineering , Indian Institute of Technology Bombay , Powai , Mumbai 400076 , India
| |
Collapse
|
49
|
Samanipour S, Reid MJ, Bæk K, Thomas KV. Combining a Deconvolution and a Universal Library Search Algorithm for the Nontarget Analysis of Data-Independent Acquisition Mode Liquid Chromatography-High-Resolution Mass Spectrometry Results. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:4694-4701. [PMID: 29561135 DOI: 10.1021/acs.est.8b00259] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Nontarget analysis is considered one of the most comprehensive tools for the identification of unknown compounds in a complex sample analyzed via liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS). Due to the complexity of the data generated via LC-HRMS, the data-dependent acquisition mode, which produces the MS2 spectra of a limited number of the precursor ions, has been one of the most common approaches used during nontarget screening. However, data-independent acquisition mode produces highly complex spectra that require proper deconvolution and library search algorithms. We have developed a deconvolution algorithm and a universal library search algorithm (ULSA) for the analysis of complex spectra generated via data-independent acquisition. These algorithms were validated and tested using both semisynthetic and real environmental data. A total of 6000 randomly selected spectra from MassBank were introduced across the total ion chromatograms of 15 sludge extracts at three levels of background complexity for the validation of the algorithms via semisynthetic data. The deconvolution algorithm successfully extracted more than 60% of the added ions in the analytical signal for 95% of processed spectra (i.e., 3 complexity levels multiplied by 6000 spectra). The ULSA ranked the correct spectra among the top three for more than 95% of cases. We further tested the algorithms with 5 wastewater effluent extracts for 59 artificial unknown analytes (i.e., their presence or absence was confirmed via target analysis). These algorithms did not produce any cases of false identifications while correctly identifying ∼70% of the total inquiries. The implications, capabilities, and the limitations of both algorithms are further discussed.
Collapse
Affiliation(s)
- Saer Samanipour
- Norwegian Institute for Water Research (NIVA) , 0349 Oslo , Norway
| | - Malcolm J Reid
- Norwegian Institute for Water Research (NIVA) , 0349 Oslo , Norway
| | - Kine Bæk
- Norwegian Institute for Water Research (NIVA) , 0349 Oslo , Norway
| | - Kevin V Thomas
- Norwegian Institute for Water Research (NIVA) , 0349 Oslo , Norway
- Queensland Alliance for Environmental Health Science (QAEHS) , University of Queensland , 39 Kessels Road , Coopers Plains , Queensland 4108 , Australia
| |
Collapse
|
50
|
Integrated SWATH-based and targeted-based proteomics provide insights into the retinal emmetropization process in guinea pig. J Proteomics 2018; 181:1-15. [PMID: 29572162 DOI: 10.1016/j.jprot.2018.03.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 03/12/2018] [Accepted: 03/19/2018] [Indexed: 01/13/2023]
Abstract
Myopia is generally regarded as a failure of normal emmetropization process, however, its underlying molecular mechanisms are unclear. To investigate the retinal protein profile changes during emmetropization, we studied differential protein expressions of ocular growth in young guinea pigs at 3 and 21 days old respectively, when significant axial elongation was detected (P < 0.001, n = 10). Independent pooled retinal samples of both eyes were subjected to SWATH mass spectrometry (MS) followed by bioinformatics analysis using cloud-based platforms. A comprehensive retina SWATH ion-library consisting of 3138 (22,871) unique proteins (peptides) at 1% FDR was constructed. 40 proteins were found to be significantly up-regulated and 8 proteins down-regulated during emmetropization (≥log2 of 0.43 with ≥2 peptides matched per protein; P < 0.05). Using pathway analysis, the most significant pathway identifiable was 'phototransduction' (P = 1.412e-4). Expression patterns of 7 proteins identified in this pathway were further validated and confirmed (P < 0.05) with high-resolution Multiple Reaction Monitoring (MRM-HR) MS. Combining discovery and targeted proteomics approaches, this study for the first time comprehensively profiled protein changes in the guinea pig retina during normal emmetropization-associated eye growth. The findings of this study are also relevant to the myopia development, which is the result of failed emmetropization. SIGNIFICANCE Myopia is considered as a failure of emmetropization. However, the underlying biochemical mechanism of emmetropization, a visually guided process in which eye grows towards the optimal optical state of clear vision during early development, is not well understood. Retina is known as the key tissue to regulate this active eye growth. we studied eye growth of young guinea pigs and harvested their retinal tissues. A comprehensive SWATH ion library with identification of a total 3138 unique proteins were established, in which 48 proteins exhibited significant differential expressions between 3 and 21 days old. After MRM-HR confirmation, 'phototransduction' were found as the most active pathway during emmetropic eye growth. This study is the first in discovering key retinal protein players and pathways which are presumably orchestrated by biological mechanism(s) underlying emmetropization.
Collapse
|