1
|
Guo X, Wang J, Bu J, Zhang H, Arshad M, Kanwal A, Majeed MK, Chen WX, Saxena KK, Liu X. Designing Nanocomposite-Based Electrochemical Biosensors for Diabetes Mellitus Detection: A Review. ACS OMEGA 2024; 9:30071-30086. [PMID: 39035943 PMCID: PMC11256292 DOI: 10.1021/acsomega.4c02540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 06/08/2024] [Accepted: 06/21/2024] [Indexed: 07/23/2024]
Abstract
This review will unveil the development of a new generation of electrochemical sensors utilizing a transition-metal-oxide-based nanocomposite with varying morphology. There has been considerable discussion on the role of transition metal oxide-based nanocomposite, including iron, nickel, copper, cobalt, zinc, platinum, manganese, conducting polymers, and their composites, in electrochemical and biosensing applications. Utilizing these materials to detect glucose and hydrogen peroxide selectively and sensitively with the correct chemical functionalization is possible. These transition metals and their oxide nanoparticles offer a potential method for electrode modification in sensors. Nanotechnology has made it feasible to develop nanostructured materials for glucose and H2O2 biosensor applications. Highly sensitive and selective biosensors with a low detection limit can detect biomolecules at nanomolar to picomolar (10-9 to 10-12 molar) concentrations to assess physiological and metabolic parameters. By mixing carbon-based materials (graphene oxide) with inorganic nanoparticles, nanocomposite biosensor devices with increased sensitivity can be made using semiconducting nanoparticles, quantum dots, organic polymers, and biomolecules.
Collapse
Affiliation(s)
- Xiang Guo
- Science and
Technology on Aerospace Chemical Power Laboratory, Laboratory of Emergency
Safety and Rescue Technology, Hubei Institute
of Aerospace Chemotechnology, Xiangyang 441003, China
| | - Jiaxin Wang
- Science and
Technology on Aerospace Chemical Power Laboratory, Laboratory of Emergency
Safety and Rescue Technology, Hubei Institute
of Aerospace Chemotechnology, Xiangyang 441003, China
| | - Jinyan Bu
- Science and
Technology on Aerospace Chemical Power Laboratory, Laboratory of Emergency
Safety and Rescue Technology, Hubei Institute
of Aerospace Chemotechnology, Xiangyang 441003, China
| | - Huichao Zhang
- Science and
Technology on Aerospace Chemical Power Laboratory, Laboratory of Emergency
Safety and Rescue Technology, Hubei Institute
of Aerospace Chemotechnology, Xiangyang 441003, China
| | - Muhammad Arshad
- Department
of Chemistry, National Sun Yat-sen University, 70 Lien-Hai Road, Kaohsiung 80424, Taiwan China
- CAS Key Laboratory
for Biomedical Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology (NCNST), Beijing 100190, China
| | - Ayesha Kanwal
- Department
of Chemistry, IRCBM, COSMAT University Islamabad, Lahore campus 54000, Lahore, Pakistan
| | - Muhammad K. Majeed
- Department
of Materials Science and Engineering, The
University of Texas at Arlington, 76019 Arlington, Texas, United States
| | - Wu-Xing Chen
- Institute
of Environmental Engineering, National Sun
Yat-Sen University, 80424 Kaohsiung, Taiwan
| | - Kuldeep K Saxena
- Division
of Research and Development, Lovely Professional
University, 144411 Phagwara, India
| | - Xinghui Liu
- Science and
Technology on Aerospace Chemical Power Laboratory, Laboratory of Emergency
Safety and Rescue Technology, Hubei Institute
of Aerospace Chemotechnology, Xiangyang 441003, China
| |
Collapse
|
2
|
Rapid preparation of CuO composite graphene for portable electrochemical sensing of sulfites based on laser etching technique. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
3
|
Cui X, Bao Y, Han T, Liu Z, Ma Y, Sun Z. A wearable electrochemical sensor based on β-CD functionalized graphene for pH and potassium ion analysis in sweat. Talanta 2022; 245:123481. [DOI: 10.1016/j.talanta.2022.123481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 04/08/2022] [Accepted: 04/13/2022] [Indexed: 12/22/2022]
|
4
|
Garima, Sachdev A, Matai I. An electrochemical sensor based on cobalt oxyhydroxide nanoflakes/reduced graphene oxide nanocomposite for detection of illicit drug-clonazepam. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
5
|
Geraskevich AV, Solomonenko AN, Dorozhko EV, Korotkova EI, Barek J. Electrochemical Sensors for the Detection of Reactive Oxygen Species in Biological Systems: A Critical Review. Crit Rev Anal Chem 2022; 54:742-774. [PMID: 35867547 DOI: 10.1080/10408347.2022.2098669] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Reactive oxygen species (ROS) involving superoxide anion, hydrogen peroxide and hydroxyl radical play important role in human health. ROS are known to be the markers of oxidative stress associated with different pathologies including neurodegenerative and cardiovascular diseases, as well as cancer. Accordingly, ROS level detection in biological systems is an essential problem for biomedical and analytical research. Electrochemical methods seem to have promising prospects in ROS determination due to their high sensitivity, rapidity, and simple equipment. This review demonstrates application of modern electrochemical sensors for ROS detection in biological objects (e.g., cell lines and body fluids) over a decade between 2011 and 2021. Particular attention is paid to sensors materials and various types of modifiers for ROS selective detection. Moreover, the sensors comparative characteristics, their main advantages, disadvantages and their possibilities and limitations are discussed.
Collapse
Affiliation(s)
- Alina V Geraskevich
- Division for Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Anna N Solomonenko
- Division for Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Elena V Dorozhko
- Division for Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Elena I Korotkova
- Division for Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Jiří Barek
- UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University, Prague 2, Czechia, Czech Republic
| |
Collapse
|
6
|
Dong Y, Zhao T, Zhong D, Liu G, Hao G, Li J, Zhao Q. Amorphous CoV phosphate nanosheets as efficient oxygen evolution electrocatalyst. Chem Asian J 2022; 17:e202200126. [PMID: 35293701 DOI: 10.1002/asia.202200126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 03/12/2022] [Indexed: 11/11/2022]
Abstract
Oxygen evolution reaction (OER) is crucial for hydrogen production. However, OER with four-electron transfer requires electrocatalysts to speed up its sluggish kinetics in alkaline solutions. Herein, amorphous CoV phosphate (denoted as CoV-Pi) nanosheets synthesized by a straightforward one-step hydrothermal approach is reported, which provide a low overpotential of 320 mV at 10 mA cm-2 , a small Tafel slope down to 48.8 mV dec-1 and long-term durability over 80 h. The efficient activity is ascribed to the amorphous nanosheets structure, high electrochemically active surface area, enhanced surface wettability and the synergistic effect of the active metal atoms. This study significantly indicates that CoV-Pi is a promising alternative to replace expensive noble metal-based catalysts for electrochemical water splitting.
Collapse
Affiliation(s)
- Yuming Dong
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, CHINA
| | - Tao Zhao
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, CHINA
| | - Dazhong Zhong
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, CHINA
| | - Guang Liu
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, CHINA
| | - Genyan Hao
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, CHINA
| | - Jinping Li
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, CHINA
| | - Qiang Zhao
- Taiyuan University of Technology, College of Chemistry and Chemical Engineering, No.79 West Yingze Street, 030024, Taiyuan, CHINA
| |
Collapse
|
7
|
Mei T, Zhang S, Sun J, Hu Y. 2D CoOOH nanosheets as oxidase mimic for the colorimetric assay of sulfite in food. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:764-768. [PMID: 33566878 DOI: 10.1039/d1ay00039j] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Here, we report a rapid, sensitive and selective colorimetric assay for sulfite (SO32-) based on the intrinsic oxidase-like activity of 2D cobalt oxyhydroxide nanosheets (CoOOH NSs). The 2D CoOOH nanozyme could directly oxidize 3,3',5,5'-tetramethylbenzidine (TMB) into blue products (TMBox) in an aerobic solution without H2O2. Interestingly, the presence of SO32- could effectively inhibit the CoOOH NS-O2-TMB reaction system and thus caused changes in color and absorbance, which facilitated a colorimetric sensor for sulfite. After optimizing detection conditions, a facile and robust approach was developed for SO32- detection in food.
Collapse
Affiliation(s)
- Tianxiao Mei
- Institute for Regenerative Medicine, Shanghai East Hospital, School of Life Sciences and Technology, Tongji University, Shanghai 200092, China.
| | - Sheng Zhang
- Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, China Pharmaceutical University, Nanjing 210009, China
| | - Jie Sun
- Shanghai Blood Center, Shanghai 200051, China
| | - Yihui Hu
- Institute for Regenerative Medicine, Shanghai East Hospital, School of Life Sciences and Technology, Tongji University, Shanghai 200092, China. and Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, China Pharmaceutical University, Nanjing 210009, China
| |
Collapse
|
8
|
Guan JF, Huang ZN, Zou J, Jiang XY, Peng DM, Yu JG. A sensitive non-enzymatic electrochemical sensor based on acicular manganese dioxide modified graphene nanosheets composite for hydrogen peroxide detection. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2020; 190:110123. [PMID: 31891837 DOI: 10.1016/j.ecoenv.2019.110123] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 12/16/2019] [Accepted: 12/21/2019] [Indexed: 06/10/2023]
Abstract
In this work, a novel manganese dioxide-graphene nanosheets (MnO2-GNSs) composite was synthesized by a facile one-step hydrothermal method, in which manganese dioxide (MnO2) was fabricated by hydrothermal reduction of KMnO4 with GNSs. The structure and morphology of MnO2-GNSs composite were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) analysis and X-ray photoelectron spectroscopy (XPS). A sensitive non-enzymatic electrochemical sensor based on MnO2-GNSs composite for the detection of low concentration hydrogen peroxide (H2O2) was fabricated. The electrochemical properties of MnO2-GNSs composite modified glassy carbon electrode (MnO2-GNSs/GCE) were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and amperometry. The observations confirmed that the fabricated sensor exhibited high electrocatalytic activity for oxidation of H2O2 owing to the catalytic ability of MnO2 particles and the conductivity of GNSs. Under the optimum conditions, the calibration curve was linear for the amperometric response versus H2O2 concentration over the range 0.5-350 μM with a low detection limit of 0.19 μM (S/N = 3) and high sensitivity of 422.10 μA mM-1 cm-2. The determination and quantitative analysis of H2O2 in antiseptic solution on MnO2-GNSs/GCE exhibited percent recovery of 96.50%-101.22% with relative standard deviation (RSD) of 1.48%-4.47%. The developed MnO2-GNSs/GCE might be a promising platform for the practical detection of H2O2 due to its prominent properties including excellent reproducibility, good anti-interference and repeatability.
Collapse
Affiliation(s)
- Jin-Feng Guan
- College of Chemistry and Chemical Engineering, Hunan Provincial Key Laboratory of Efficient and Clean Utilization of Manganese Resources, Central South University, Changsha, Hunan, 410083, China
| | - Zhao-Ning Huang
- College of Chemistry and Chemical Engineering, Hunan Provincial Key Laboratory of Efficient and Clean Utilization of Manganese Resources, Central South University, Changsha, Hunan, 410083, China
| | - Jiao Zou
- College of Chemistry and Chemical Engineering, Hunan Provincial Key Laboratory of Efficient and Clean Utilization of Manganese Resources, Central South University, Changsha, Hunan, 410083, China
| | - Xin-Yu Jiang
- College of Chemistry and Chemical Engineering, Hunan Provincial Key Laboratory of Efficient and Clean Utilization of Manganese Resources, Central South University, Changsha, Hunan, 410083, China
| | - Dong-Ming Peng
- School of Pharmacy, Hunan University of Chinese Medicine, Changsha, 410208, China.
| | - Jin-Gang Yu
- College of Chemistry and Chemical Engineering, Hunan Provincial Key Laboratory of Efficient and Clean Utilization of Manganese Resources, Central South University, Changsha, Hunan, 410083, China.
| |
Collapse
|
9
|
Cui X, Cao D, Djellabi R, Qiao M, Wang Y, Zhao S, Mao R, Gong Y, Zhao X, Yang B. Enhancement of Ni/NiO/graphitized carbon and β-Cyclodextrin/reduced graphene oxide for the electrochemical detection of norfloxacin in water sample. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113407] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
10
|
Cui X, Yue C, Zhu R, Fang W, Wang J, Zhao H, Li Z. Nitrogen-doped-carbon-coated hexagonal cobalt oxyhydroxide/reduced graphene oxide nanocomposite for sensitive and selective detection of nitrite in human hepatoma cells. NANOTECHNOLOGY 2019; 30:265502. [PMID: 30802895 DOI: 10.1088/1361-6528/ab0a48] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Selective and sensitive determination of nitrite is of great importance in practical application. In the present work, a novel nitrite sensing platform was built based on the fabrication of nitrogen-doped-carbon-coated hexagonal cobalt oxyhydroxide (CN@CoOOH) on reduced graphene oxide (RGO) using zeolitic imidazolate framework (ZIF)-67 as a precursor. The CN@CoOOH/RGO nanocomposite was confirmed by UV-visible spectroscopy, Fourier transform infrared spectroscopy, x-ray photoelectron spectrum, transmission electron microscopy, scanning electron microscopy, and x-ray diffraction. We applied the nanocomposite to detect nitrite selectively and sensitively through amperometry for the first time. The anodic current values increased with the addition of nitrite. Therefore, the concentrations of nitrite were quantitatively detected using a CN@CoOOH/RGO based sensor. A wider linear range of 0.1 to 7000 μM was obtained with a lower detection limit of 10 nM (S/N = 3). The proposed method was also applied to detect nitrite released from normal liver cells and human hepatoma cells.
Collapse
|
11
|
Taniselass S, Md Arshad M, Gopinath SC. Current state of green reduction strategies: Solution-processed reduced graphene oxide for healthcare biodetection. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 96:904-914. [DOI: 10.1016/j.msec.2018.11.062] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 10/27/2018] [Accepted: 11/27/2018] [Indexed: 12/17/2022]
|