1
|
Cai Z, Zhu C, Hu A, Chen G. An "on-off-on" Fluorescent Sensor Based on Carbon Dots for the Detection of Au (III) and Creatinine. J Fluoresc 2025; 35:661-672. [PMID: 38148407 DOI: 10.1007/s10895-023-03567-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 12/20/2023] [Indexed: 12/28/2023]
Abstract
The present study proposes a new approach for detecting trace amounts of creatinine (Cre) through the utilization of a fluorescence sensor system consisting of nitrogen doped carbon dots (NCDs) and gold ions (Au3+). Yellow fluorescent carbon dots were prepared using a one-step hydrothermal method with o-phenylenediamine and isopropanol as raw materials. First, gold ions are reduced to gold nanoparticles (Au NPs), which bind to NCDs, resulting in electron transfer and fluorescence quenching of NCDs. After adding creatinine, Cre and Au NPs were preferentially combined to form non-fluorescent complexes, and the NCDs fluorescence was restored. The study achieved a detection limit of 1.06 × 10-7 M for Au3+ and 9.29 × 10-9 M for creatinine, indicating a high level of sensitivity. The sensing system has also been successfully utilized for detecting Au3+ in lake water and Cre in human urine, indicating its promising potential and practical applications in the areas of environmental monitoring and biosensing.
Collapse
Affiliation(s)
- Zicheng Cai
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Chun Zhu
- School of Science, Jiangnan University, Wuxi, 214122, China.
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China.
| | - Anqi Hu
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Guoqing Chen
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| |
Collapse
|
2
|
Bais S, Singh PK. Al 3+-Responsive Ratiometric Fluorescent Sensor for Creatinine Detection: Thioflavin-T and Sulfated-β-Cyclodextrin Synergy. ACS APPLIED BIO MATERIALS 2023; 6:4146-4157. [PMID: 37702182 DOI: 10.1021/acsabm.3c00349] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
Kidney disorders are a rising global health issue, necessitating early diagnosis for effective treatment. Creatinine, a metabolic waste product from muscles, serves as an ideal biomarker for kidney damage. The existing optical methods for creatinine detection often involve labor-intensive synthesis processes and present challenges with the aqueous solubility and sensitivity to experimental variations. In this study, we introduce a straightforward fluorescence "turn-on" ratiometric sensor system for creatinine detection in aqueous media with a limit of detection of 0.5 μM. The sensor is based on sulfated-β-cyclodextrin (SCD)-templated H-aggregate of a commercially available, ultrafast rotor dye thioflavin-T (ThT). The Al3+ ion-induced dissociation of ThT-SCD aggregates, followed by reassociation upon creatinine addition, generates a detectable signal. The modulation of monomer/aggregate equilibrium due to the disassembly/reassembly of the ThT-SCD system under Al3+/creatinine influence serves as the optimal strategy for ratiometric creatinine detection in aqueous media. Our sensor framework offers several advantages: utilization of the readily available dye ThT, which eliminates the need for a laborious synthesis of custom fluorescent probes; ratiometric sensing, which improves quantitative analysis accuracy; and compatibility with complex aqueous media. The sensor's practical utility has been successfully demonstrated in artificial urine samples. In summary, our sensor system represents a significant advancement in the rapid, selective, and sensitive detection of the clinically crucial bioanalyte creatinine, offering potential benefits for the early diagnosis and management of kidney disorders.
Collapse
Affiliation(s)
- Sujata Bais
- Radiation & Photochemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India
| | - Prabhat K Singh
- Radiation & Photochemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India
- Homi Bhabha National Institute, Training School Complex, Anushaktinagar, Mumbai 400094, India
| |
Collapse
|
3
|
Francis S, Sunny N, Rajith L. Picomolar Selective Fluorescent Detection of Creatinine Using Porphyrin in Aqueous Medium. J Photochem Photobiol A Chem 2022. [DOI: 10.1016/j.jphotochem.2022.114534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
4
|
Ortiz-Gómez I, Ramírez-Rodríguez GB, Capitán-Vallvey LF, Salinas-Castillo A, Delgado-López JM. Highly stable luminescent europium-doped calcium phosphate nanoparticles for creatinine quantification. Colloids Surf B Biointerfaces 2020; 196:111337. [PMID: 32949922 DOI: 10.1016/j.colsurfb.2020.111337] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 07/31/2020] [Accepted: 08/13/2020] [Indexed: 11/28/2022]
Abstract
The determination of creatinine levels is essential for the detection of renal and muscular dysfunction. Luminescent nanoparticles are emerging as fast, cheap and highly selective sensors for the detection and quantification of creatinine. Nevertheless, current nanosensors only have a short shelf life due to their poor chemical and colloidal stability, which limits their clinical functionality. In this work, we have developed a highly stable, selective and sensitive nanosensor based on europium-doped, amorphous calcium phosphate nanoparticles (Eu-ACP) for the determination of creatinine by luminescence spectroscopy. The colloidal stability of Eu-ACP nanoparticles in aqueous solutions was optimised to ensure a constant signal after up to 4 months in storage. The luminescence intensity of Eu-ACP decreased linearly with the creatinine concentration over the range of 1-120 μM (R2 = 0.995). This concentration-response relationship was used to determine creatinine levels in real urine samples resulting in good recovery percentages. Significantly, selectivity assays indicated that none of the potential interfering species provoked discernible changes in the luminescence intensity.
Collapse
Affiliation(s)
- Inmaculada Ortiz-Gómez
- Department of Analytical Chemistry, University of Granada, Faculty of Science, Av. Fuente Nueva, s/n, 18071 Granada, Spain; Unit of Excellence in Chemistry applied to Biomedicine and the Environment of the University of Granada, Spain
| | - Gloria B Ramírez-Rodríguez
- Department of Inorganic Chemistry, University of Granada, Faculty of Science, Av. Fuente Nueva, s/n, 18071 Granada, Spain; Unit of Excellence in Chemistry applied to Biomedicine and the Environment of the University of Granada, Spain.
| | - Luis F Capitán-Vallvey
- Department of Analytical Chemistry, University of Granada, Faculty of Science, Av. Fuente Nueva, s/n, 18071 Granada, Spain; Unit of Excellence in Chemistry applied to Biomedicine and the Environment of the University of Granada, Spain
| | - Alfonso Salinas-Castillo
- Department of Analytical Chemistry, University of Granada, Faculty of Science, Av. Fuente Nueva, s/n, 18071 Granada, Spain; Unit of Excellence in Chemistry applied to Biomedicine and the Environment of the University of Granada, Spain
| | - José M Delgado-López
- Department of Inorganic Chemistry, University of Granada, Faculty of Science, Av. Fuente Nueva, s/n, 18071 Granada, Spain; Unit of Excellence in Chemistry applied to Biomedicine and the Environment of the University of Granada, Spain.
| |
Collapse
|
5
|
Kumar P, Kamboj M, Jaiwal R, Pundir CS. Fabrication of an improved amperometric creatinine biosensor based on enzymes nanoparticles bound to Au electrode. Biomarkers 2019; 24:739-749. [PMID: 31617777 DOI: 10.1080/1354750x.2019.1682045] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
An improved amperometric creatinine biosensor was fabricated that dependent on covalent immobilisation of nanoparticles of creatininase (CANPs), creatinase (CINPs) and sarcosine oxidase (SOxNPs) onto gold electrode (AuE). The CANPs/CINPs/SOxNPs/AuE was characterised by scanning electron microscopy and cyclic voltammetry at various stages. The working electrode exhibited optimal response within 2 s at a potential of 0.6 V, against Ag/AgCl, pH 6.5 and 30 °C. A linear relationship was observed between creatinine concentration range, 0.1-200μM and biosensor response i.e. current in mA, under optimum conditions. Biosensor offered a low detection limit of 0.1 μM with long storage stability. Analytical recoveries of added creatinine in blood sera at 0.5 mM and at 1.0 mM concentrations, were 92.0% and 79.20% respectively. The precision i.e. within and between-batch coefficients of variation were 2.04% and 3.06% respectively. There was a good correlation (R2 = 0.99) between level of creatinine in sera, as calculated by the colorimetric method and present electrode. The CANPs/CINPs/SOxNPs/Au electrode was reused 200 times during the period of 180 days, with just 10% loss in its initial activity, while being stored at 4 °C, when not in use.HighlightsPrepared and characterised creatininase (CA), creatinase (CI) sarcosine oxidase (SOx) nanoparticles and immobilised them onto gold electrode (AuE) for fabrication of an improved amperometric creatinine biosensor.The biosensor displayed a limit of detection (LOD) of 0.1 μM with a linear working range of 0.1 μM-200 μM.The biosensor was evaluated and applied to measure elevated creatinine levels in sera from whom suffering from kidney and muscular disorders.The working electrode retained 90% of its initial activity, while being stored dry at 4 ˚C for 180 days.
Collapse
Affiliation(s)
- Parveen Kumar
- Department of Biochemistry, M.D. University, Rohtak, India
| | - Mohit Kamboj
- Department of Zoology, M.D. University, Rohtak, India
| | | | - C S Pundir
- Department of Biochemistry, M.D. University, Rohtak, India
| |
Collapse
|
6
|
Hao Y, Yin Q, Zhang Y, Xu M, Chen S. Recent Progress in the Development of Fluorescent Probes for Thiophenol. Molecules 2019; 24:E3716. [PMID: 31623065 PMCID: PMC6832550 DOI: 10.3390/molecules24203716] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 10/14/2019] [Accepted: 10/14/2019] [Indexed: 02/07/2023] Open
Abstract
Thiophenol (PhSH) belongs to a class of highly reactive and toxic aromatic thiols with widespread applications in the chemical industry for preparing pesticides, polymers, and pharmaceuticals. In this review, we comprehensively summarize recent progress in the development of fluorescent probes for detecting and imaging PhSH. These probes are classified according to recognition moieties and are detailed on the basis of their structures and sensing performances. In addition, prospects for future research are also discussed.
Collapse
Affiliation(s)
- Yuanqiang Hao
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China.
- Key Laboratory of Theoretical Organic Chemistry and Function Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China.
| | - Qianye Yin
- Key Laboratory of Theoretical Organic Chemistry and Function Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China.
| | - Yintang Zhang
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China.
| | - Maotian Xu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China.
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, China.
| | - Shu Chen
- Key Laboratory of Theoretical Organic Chemistry and Function Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China.
| |
Collapse
|
7
|
Development of a new fluorescent probe for cysteine detection in processed food samples. Anal Bioanal Chem 2019; 411:6203-6212. [PMID: 31300856 DOI: 10.1007/s00216-019-02012-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 06/15/2019] [Accepted: 07/01/2019] [Indexed: 10/26/2022]
Abstract
Cysteine is a crucial amino acid, found in a huge amount in protein-rich foods. We focused our research to determine the amount of free cysteine consumed highly in foods such as pork, beef, poultry, eggs, dairy, red peppers, soybeans, broccoli, brussels sprouts, oats, and wheat germs. A newly designed carbazole-pyridine-based fluorescent probe (CPI) has been introduced for quantitative estimation of cysteine (Cys) with a "turn on" fluorescence in some popular processed food samples chosen from our daily diet. CPI shows both naked eye and UV-visible color changes upon interaction with cysteine. The binding approach between CPI and Cys at biological pH has been thoroughly explored by UV-visible and fluorescence spectroscopy. From Job's plot analysis, 1:1 stoichiometric reaction between CPI and Cys is observed with a detection limit of 3.8 μM. NMR, ESI mass spectrometry, and time-dependent density functional theory (TD-DFT) study enlightens the formation of more stable product CPI-Cys. The "turn on" response of the probe CPI occurs due to the interruption of intra-molecular charge transfer (ICT) process upon reacting with cysteine. Moreover, CPI is a very stable, cost-effective compound and exhibits excellent real-time selectivity towards Cys over all other comparative biorelevant analytes. Interestingly, our proposed method is much advantageous as it is able to estimate cysteine predominantly by screening out other comparative biocomponents found in different protein-rich foods.
Collapse
|