1
|
Derichsweiler C, Herbertz S, Kruss S. Optical Bionanosensors for Sepsis Diagnostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2025; 21:e2409042. [PMID: 39745136 PMCID: PMC11855245 DOI: 10.1002/smll.202409042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Revised: 11/29/2024] [Indexed: 02/26/2025]
Abstract
Sepsis is a global health challenge, characterized by a dysregulated immune response, leading to organ dysfunction and death. Despite advances in medical care, sepsis continues to claim a significant toll on human lives, with mortality rates from 10-25% for sepsis and 30-50% for septic shock, making it a leading cause of death worldwide. Current diagnostic methods rely on clinical signs, laboratory parameters, or microbial cultures and suffer from delays and inaccuracies. Therefore, there is a pressing need for novel diagnostic tools that can rapidly and accurately identify sepsis. This review highlights advances in biosensor development that could ultimately lead to faster and more accurate sepsis diagnostics. The focus is on nanomaterial-based optical approaches that promise rapid diagnostics without the need for large equipment or trained personnel. An overview of sepsis is provided, highlighting potential molecular targets and the challenges they present for assay development. The requirements for an ideal point-of-care test (POC) are discussed, including speed, simplicity, and cost-effectiveness. Different nanomaterials suitable for various optical detection methods are reviewed and innovative nanosensors are discussed for sepsis diagnostics, focusing on chemical design and approaches to increase selectivity by multiplexing.
Collapse
Affiliation(s)
- Christina Derichsweiler
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 6147057DuisburgGermany
- Physical ChemistryRuhr‐University Bochum Universitätsstrasse 15044801BochumGermany
| | - Svenja Herbertz
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 6147057DuisburgGermany
| | - Sebastian Kruss
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 6147057DuisburgGermany
- Physical ChemistryRuhr‐University Bochum Universitätsstrasse 15044801BochumGermany
| |
Collapse
|
2
|
Strohmaier-Nguyen D, Horn C, Baeumner AJ. Innovations in one-step point-of-care testing within microfluidics and lateral flow assays for shaping the future of healthcare. Biosens Bioelectron 2025; 267:116795. [PMID: 39332251 DOI: 10.1016/j.bios.2024.116795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 08/31/2024] [Accepted: 09/17/2024] [Indexed: 09/29/2024]
Abstract
Point-of-care testing (POCT) technology, using lateral flow assays and microfluidic systems, facilitates cost-effective diagnosis, timely treatment, ongoing monitoring, and prevention of life-threatening outcomes. Aside from significant advancements demonstrated in academic research, implementation in real-world applications remains frustratingly limited. The divergence between academic developments and practical utility is often due to factors such as operational complexity, low sensitivity and the need for trained personnel. Taking this into consideration, our objective is to present a critical and objective overview of the latest advancements in fully integrated one-step POCT assays for home-testing which would be commercially viable. In particular, aspects of signal amplification, assay design modification, and sample preparation are critically evaluated and their features and medical applications along with future perspective and challenges with respect to minimal user intervention are summarized. Associated with and very important for the one-step POCT realization are also readout devices and fabrication processes. Critical analysis of available and useful technologies are presented in the SI section.
Collapse
Affiliation(s)
- Dan Strohmaier-Nguyen
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany
| | - Carina Horn
- Roche Diagnostics GmbH, 68305, Mannheim, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany.
| |
Collapse
|
3
|
Phunpae P, Thongkum W, Panyasit W, Laopajon W, Takheaw N, Pata S, Yasamut U, Kasinrerk W, Tayapiwatana C. Rapid lateral flow test for Mycobacterium tuberculosis complex and non-tuberculous mycobacteria differentiation. Appl Microbiol Biotechnol 2024; 108:456. [PMID: 39222096 PMCID: PMC11369055 DOI: 10.1007/s00253-024-13293-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2024] [Revised: 08/03/2024] [Accepted: 08/19/2024] [Indexed: 09/04/2024]
Abstract
The diagnosis of mycobacterial infections, including both the Mycobacterium tuberculosis complex (MTBC) and non-tuberculous mycobacteria (NTM), poses a significant global medical challenge. This study proposes a novel approach using immunochromatographic (IC) strip tests for the simultaneous detection of MTBC and NTM. Traditional methods for identifying mycobacteria, such as culture techniques, are hindered by delays in distinguishing between MTBC and NTM, which can affect patient care and disease control. Molecular methods, while sensitive, are resource-intensive and unable to differentiate between live and dead bacteria. In this research, we developed unique monoclonal antibodies (mAbs) against Ag85B, a mycobacterial secretory protein, and successfully implemented IC strip tests named 8B and 9B. These strips demonstrated high concordance rates with conventional methods for detecting MTBC, with positivity rates of 93.9% and 85.9%, respectively. For NTM detection, the IC strip tests achieved a 63.2% detection rate compared to culture methods, considering variations in growth rates among different NTM species. Furthermore, this study highlights a significant finding regarding the potential of MPT64 and Ag85B proteins as markers for MTBC detection. In conclusion, our breakthrough method enables rapid and accurate detection of both MTBC and NTM bacteria within the BACTEC MGIT system. This approach represents a valuable tool in clinical settings for distinguishing between MTBC and NTM infections, thereby enhancing the management and control of mycobacterial diseases. KEY POINTS: • Panel of mAbs for differentiating MTB versus NTM • IC strips for diagnosing MTBC and NTM after the BACTEC MGIT • Combined detection of MTP64 and Ag85B enhances diagnostic accuracy.
Collapse
Affiliation(s)
- Ponrut Phunpae
- Division of Clinical Microbiology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Weeraya Thongkum
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
- Center of Innovative Immunodiagnostic Development, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Wutthichai Panyasit
- Office of Disease Prevention and Control Region 1, Chiang Mai, 50100, Thailand
| | - Witida Laopajon
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
- Biomedical Technology Research Center, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency at the Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Nuchjira Takheaw
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
- Biomedical Technology Research Center, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency at the Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Supansa Pata
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
- Biomedical Technology Research Center, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency at the Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Umpa Yasamut
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
- Center of Innovative Immunodiagnostic Development, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Watchara Kasinrerk
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand.
- Biomedical Technology Research Center, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency at the Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand.
| | - Chatchai Tayapiwatana
- Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand.
- Center of Innovative Immunodiagnostic Development, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand.
| |
Collapse
|
4
|
Park S, Gordon CT, Swager TM. Resistivity detection of perfluoroalkyl substances with fluorous polyaniline in an electrical lateral flow sensor. Proc Natl Acad Sci U S A 2024; 121:e2317300121. [PMID: 38470924 PMCID: PMC10963003 DOI: 10.1073/pnas.2317300121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 02/06/2024] [Indexed: 03/14/2024] Open
Abstract
Perfluoroalkyl substances (PFAS), known as "forever chemicals," are a growing concern in the sphere of human and environmental health. In response, rapid, reproducible, and inexpensive methods for PFAS detection in the environment and home water supplies are needed. We have developed a simple and inexpensive perfluoroalkyl acid detection method based on an electrically read lateral flow assay (e-LFA). Our method employs a fluorous surfactant formulation with undoped polyaniline (F-PANI) fabricated to create test lines for the lateral flow assay. In perfluoroalkyl acid sensing studies, an increase in conductivity of the F-PANI film is caused by acidification and doping of PANI. A conductivity enhancement by 104-fold can be produced by this method, and we demonstrate a limit of detection for perfluorooctanoic acid (PFOA) of 400 ppt and perfluorobutanoic acid of 200 ppt. This method for PFOA detection can be expanded for wide-scale environmental and at-home water testing.
Collapse
Affiliation(s)
- Sohyun Park
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA02139
| | - Collette T. Gordon
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA02139
| | - Timothy M. Swager
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA02139
| |
Collapse
|
5
|
Perju A, Holzhausen F, Lauerer AM, Wongkaew N, Baeumner AJ. Flow-Through Carbon Nanofiber-Based Transducer for Inline Electrochemical Detection in Paper-Based Analytical Devices. ACS APPLIED MATERIALS & INTERFACES 2023; 15:44641-44653. [PMID: 37704205 DOI: 10.1021/acsami.3c07314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/15/2023]
Abstract
Point-of-care (POC) devices are rapid, simple, portable, inexpensive, and convenient, but typically they only deliver qualitative results when used in the form of a lateral flow assay (LFA). Electrochemical detection could improve their sensitivity and ensure quantitative detection; however, a breakthrough in material-based technology is needed. We demonstrate a new concept in which electrodes are directly embedded within the lateral flow, enabling flow-through and hence interaction with the entire sample. This is accomplished through laser-induced carbon nanofibers (LCNFs) made by electrospinning Matrimid into nanofiber mats with subsequent pyrolyzing of electrode structures through a CO2 laser. Their highly porous 3D structure and superior graphene-like electrochemical properties are ideally suited for flow-through electrochemical LFA (EC-LFA), where the LCNFs are simply added in line with the other membranes. After optimization of the setup, biological binding assays typical for LFA diagnostics were successfully implemented, enabling the highly sensitive and quantitative detection of 137 pM DNA target sequences of a pathogenic organism that rivals the performance of pump-controlled microfluidic bioassays. This demonstrates that LCNF-based transducers can transform paper-based diagnostic tests to enable precise, quantitative analysis without reliance on cost-intensive read-out systems.
Collapse
Affiliation(s)
- Antonia Perju
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Ferdinand Holzhausen
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Anna-Maria Lauerer
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Nongnoot Wongkaew
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
6
|
Wu T, Yagati AK, Min J. Electrochemical Detection of Different Foodborne Bacteria for Point-of-Care Applications. BIOSENSORS 2023; 13:641. [PMID: 37367006 DOI: 10.3390/bios13060641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/06/2023] [Accepted: 06/09/2023] [Indexed: 06/28/2023]
Abstract
Bacterial infections resulting from foodborne pathogenic bacteria cause millions of infections that greatly threaten human health and are one of the leading causes of mortality around the world. To counter this, the early, rapid, and accurate detection of bacterial infections is very important to address serious health issue concerns. We, therefore, present an electrochemical biosensor based on aptamers that selectively bind with the DNA of specific bacteria for the accurate and rapid detection of various foodborne bacteria for the selective determination of bacterial infection types. Different aptamers were synthesized and immobilized on Au electrodes for selective bindings of different types of bacterial DNA (Escherichia coli, Salmonella enterica, and Staphylococcus aureus) for the accurate detection and quantification of bacterial concentrations from 101 to 107 CFU/mL without using any labeling methods. Under optimized conditions, the sensor showed a good response to the various concentrations of bacteria, and a robust calibration curve was obtained. The sensor could detect the bacterial concentration at meager quantities and possessed an LOD of 4.2 × 101, 6.1 × 101, and 4.4 × 101 CFU/mL for S. Typhimurium, E. Coli, and S. aureus, respectively, with a linear range from 100 to 104 CFU/mL for the total bacteria probe and 100 to 103 CFU/mL for individual probes, respectively. The proposed biosensor is simple and rapid and has shown a good response to bacterial DNA detections and thus can be applied in clinical applications and food safety monitoring.
Collapse
Affiliation(s)
- Tailin Wu
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
| | - Ajay Kumar Yagati
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
| | - Junhong Min
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
| |
Collapse
|
7
|
Streif S, Neckermann P, Spitzenberg C, Weiss K, Hoecherl K, Kulikowski K, Hahner S, Noelting C, Einhauser S, Peterhoff D, Asam C, Wagner R, Baeumner AJ. Liposome-based high-throughput and point-of-care assays toward the quick, simple, and sensitive detection of neutralizing antibodies against SARS-CoV-2 in patient sera. Anal Bioanal Chem 2023; 415:1421-1435. [PMID: 36754874 PMCID: PMC9909147 DOI: 10.1007/s00216-023-04548-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/21/2022] [Accepted: 01/16/2023] [Indexed: 02/10/2023]
Abstract
The emergence of severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) in 2019 caused an increased interest in neutralizing antibody tests to determine the immune status of the population. Standard live-virus-based neutralization assays such as plaque-reduction assays or pseudovirus neutralization tests cannot be adapted to the point-of-care (POC). Accordingly, tests quantifying competitive binding inhibition of the angiotensin-converting enzyme 2 (ACE2) receptor to the receptor-binding domain (RBD) of SARS-CoV-2 by neutralizing antibodies have been developed. Here, we present a new platform using sulforhodamine B encapsulating liposomes decorated with RBD as foundation for the development of both a fluorescent, highly feasible high-throughput (HTS) and a POC-ready neutralizing antibody assay. RBD-conjugated liposomes are incubated with serum and subsequently immobilized in an ACE2-coated plate or mixed with biotinylated ACE2 and used in test strip with streptavidin test line, respectively. Polyclonal neutralizing human antibodies were shown to cause complete binding inhibition, while S309 and CR3022 human monoclonal antibodies only caused partial inhibition, proving the functionality of the assay. Both formats, the HTS and POC assay, were then tested using 20 sera containing varying titers of neutralizing antibodies, and a control panel of sera including prepandemic sera and reconvalescent sera from respiratory infections other than SARS-CoV-2. Both assays correlated well with a standard pseudovirus neutralization test (r = 0.847 for HTS and r = 0.614 for POC format). Furthermore, excellent correlation (r = 0.868) between HTS and POC formats was observed. The flexibility afforded by liposomes as signaling agents using different dyes and sizes can hence be utilized in the future for a broad range of multianalyte neutralizing antibody diagnostics.
Collapse
Affiliation(s)
- Simon Streif
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Patrick Neckermann
- Institute of Medical Microbiology & Hygiene, Molecular Microbiology (Virology), University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Clemens Spitzenberg
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Katharina Weiss
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Kilian Hoecherl
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Kacper Kulikowski
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Sonja Hahner
- Mikrogen GmbH, Floriansbogen 2-4, 82061, Neuried, Germany
| | | | - Sebastian Einhauser
- Institute of Medical Microbiology & Hygiene, Molecular Microbiology (Virology), University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - David Peterhoff
- Institute of Medical Microbiology & Hygiene, Molecular Microbiology (Virology), University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
- Institute of Clinical Microbiology and Hygiene, University Hospital Regensburg, Regensburg, Germany
| | - Claudia Asam
- Institute of Medical Microbiology & Hygiene, Molecular Microbiology (Virology), University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
| | - Ralf Wagner
- Institute of Medical Microbiology & Hygiene, Molecular Microbiology (Virology), University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany
- Institute of Clinical Microbiology and Hygiene, University Hospital Regensburg, Regensburg, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstr. 31, 93053, Regensburg, Germany.
| |
Collapse
|
8
|
Rink S, Baeumner AJ. Progression of Paper-Based Point-of-Care Testing toward Being an Indispensable Diagnostic Tool in Future Healthcare. Anal Chem 2023; 95:1785-1793. [PMID: 36608282 DOI: 10.1021/acs.analchem.2c04442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Point-of-care (POC) diagnostics in particular focuses on the timely identification of harmful conditions close to the patients' needs. For future healthcare these diagnostics could be an invaluable tool especially in a digitalized or telemedicine-based system. However, while paper-based POC tests, with the most prominent example being the lateral flow assay (LFA), have been especially successful due to their simplicity and timely response, the COVID-19 pandemic highlighted their limitations, such as low sensitivity and ambiguous responses. This perspective discusses strategies that are currently being pursued to evolve such paper-based POC tests toward a superior diagnostic tool that provides high sensitivities, objective result interpretation, and multiplexing options. Here, we pinpoint the challenges with respect to (i) measurability and (ii) public applicability, exemplified with select cases. Furthermore, we highlight promising endeavors focused on (iii) increasing the sensitivity, (iv) multiplexing capability, and (v) objective evaluation to also ready the technology for integration with machine learning into digital diagnostics and telemedicine. The status quo in academic research and industry is outlined, and the likely highly relevant role of paper-based POC tests in future healthcare is suggested.
Collapse
Affiliation(s)
- Simone Rink
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
9
|
Li J, Yuan W, Luo SXL, Bezdek MJ, Peraire-Bueno A, Swager TM. Wireless Lateral Flow Device for Biosensing. J Am Chem Soc 2022; 144:15786-15792. [PMID: 35976081 DOI: 10.1021/jacs.2c06579] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Many biosensing methods rely on signals produced by enzyme-catalyzed reactions and efficient methods to detect and record this activity. Herein, we report a wireless lateral flow device and demonstrate the conversion of oxidase reactions to changes in the resonance of radio frequency identification (RFID) circuits. The detection is triggered by polyoxometalate-catalyzed oxidative doping of polypyrrole (pPy) when exposed to oxidase-generated H2O2. We have integrated this transduction and RFID capability into a lateral flow device to create a low-cost, rapid, and portable method for quantitative biological signal detection. We further report a new method for creating functional coatings from pPy core-shell colloidal particles bioconjugated for streptavidin-biotin recognition with glucose oxidase or pyruvate oxidase. The biofunctionalized pPy particles coalesce on the nitrocellulose membrane to produce a chemiresistive band. Glucose or pyruvate solutions result in formation of H2O2 at the pPy bands, functionalized with the respective oxidase, to produce conductivity enhancements exceeding 7·105%. Placing the pPy band in the RFID circuit converts the resistivity response to a change of RF resonance. The enzymatic response of glucose oxidase is recorded within 30 min with as low as 0.6 mM of glucose using this lateral flow device. Pyruvate is also shown to produce large responses. The oxidase enzymes/pPy transduction establishes a resistivity-based platform for the construction of a new family of lateral flow devices capable of detecting and quantifying biological targets.
Collapse
Affiliation(s)
- Jie Li
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Weize Yuan
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Shao-Xiong Lennon Luo
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Máté J Bezdek
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Alexander Peraire-Bueno
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Timothy M Swager
- Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|