1
|
Suherman AL, Ngamchuea K, Tanner EEL, Sokolov SV, Holter J, Young NP, Compton RG. Electrochemical Detection of Ultratrace (Picomolar) Levels of Hg2+ Using a Silver Nanoparticle-Modified Glassy Carbon Electrode. Anal Chem 2017; 89:7166-7173. [DOI: 10.1021/acs.analchem.7b01304] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Alex L. Suherman
- Department
of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Kamonwad Ngamchuea
- Department
of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Eden E. L. Tanner
- Department
of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Stanislav V. Sokolov
- Department
of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Jennifer Holter
- Department
of Materials, University of Oxford, Parks Road, OxfordOX1 3PH, United Kingdom
| | - Neil P. Young
- Department
of Materials, University of Oxford, Parks Road, OxfordOX1 3PH, United Kingdom
| | - Richard G. Compton
- Department
of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| |
Collapse
|
2
|
Svanberg-Larsson J, Nelson GW, Escobar Steinvall S, Leo BF, Brooke E, Payne DJ, Foord JS. A Comparison of Explicitly-terminated Diamond Electrodes Decorated with Gold Nanoparticles. ELECTROANAL 2015. [DOI: 10.1002/elan.201500442] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
3
|
Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection–anodic stripping voltammetry. Anal Chim Acta 2014; 852:55-62. [DOI: 10.1016/j.aca.2014.09.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 09/05/2014] [Accepted: 09/09/2014] [Indexed: 11/23/2022]
|
4
|
Battistel D, Baldi F, Marchetto D, Gallo M, Daniele S. A rapid electrochemical procedure for the detection of Hg(0) produced by mercuric-reductase: application for monitoring Hg-resistant bacteria activity. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2012; 46:10675-10681. [PMID: 22928857 DOI: 10.1021/es301444a] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
In this work, gold microelectrodes are employed as traps for the detection of volatilized metallic mercury produced by mercuric reductase (MerA) extracted from an Hg-resistant Pseudomonas putida strain FB1. The enzymatic reduction of Hg (II) to Hg (0) was induced by NADPH cofactor added to the samples. The amount of Hg(0) accumulated on the gold microelectrode surface was determined by anodic stripping voltammetry (ASV) after transferring the gold microelectrode in an aqueous solution containing 0.1 M HNO(3) + 1 M KNO(3). Electrochemical measurements were combined with spectrofluorometric assays of NADPH consumption to derive an analytical expression for the detection of a relative MerA activity of different samples with respect to that of P. putida. The method developed here was employed for the rapid determination of MerA produced by bacteria harbored in soft tissues of clams (Ruditapes philippinarum), collected in high Hg polluted sediments of Northern Adriatic Sea in Italy.
Collapse
Affiliation(s)
- Dario Battistel
- Dipartimento di Scienze Molecolari e Nanosistemi, Università Cà Foscari Venezia, Calle Larga S. Marta 2137 - 30127 Venice, Italy.
| | | | | | | | | |
Collapse
|
5
|
|
6
|
Korolczuk M, Stepniowska A. Stripping Voltammetric Determination of Methylmercury in the Presence of Inorganic Mercury. ELECTROANAL 2010. [DOI: 10.1002/elan.201000073] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
7
|
SAHOO S, SATPATI AK, REDDY AVR. Voltammetric Determination of Trace Levels of Hg in Ayurvedic Medicine and in Cobalt-Containing Samples Using a Carbon Paste Electrode. ANAL SCI 2010; 26:1309-12. [DOI: 10.2116/analsci.26.1309] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- S. SAHOO
- Analytical Chemistry Division, Bhabha Atomic Research Centre
| | - A. K. SATPATI
- Analytical Chemistry Division, Bhabha Atomic Research Centre
| | - A. V. R. REDDY
- Analytical Chemistry Division, Bhabha Atomic Research Centre
| |
Collapse
|
8
|
|
9
|
Stozhko NY, Malakhova NA, Fyodorov MV, Brainina KZ. Modified carbon-containing electrodes in stripping voltammetry of metals. Part II. Composite and microelectrodes. J Solid State Electrochem 2007. [DOI: 10.1007/s10008-007-0474-2] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
10
|
Dong H, Lin L, Zheng H, Zhao G, Ye B. Electrode Modified with Langmuir–Blodgett (LB) Film of Calixarenes for Preconcentration and Stripping Analysis of Hg(II). ELECTROANAL 2006. [DOI: 10.1002/elan.200603520] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
11
|
Ordeig O, Banks C, del Campo J, Muñoz F, Compton R. Trace Detection of Mercury(II) Using Gold Ultra-Microelectrode Arrays. ELECTROANAL 2006. [DOI: 10.1002/elan.200503437] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
12
|
Skogvold S, Mikkelsen Ø, Schrøder K. Electrochemical Properties and Application of Mixed Silver-Bismuth Electrodes. ELECTROANAL 2005. [DOI: 10.1002/elan.200503328] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
13
|
Manivannan A, Ramakrishnan L, Seehra M, Granite E, Butler J, Tryk D, Fujishima A. Mercury detection at boron doped diamond electrodes using a rotating disk technique. J Electroanal Chem (Lausanne) 2005. [DOI: 10.1016/j.jelechem.2004.12.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
14
|
Manivannan A, Seehra MS, Tryk DA, Fujishima A. ELECTROCHEMICAL DETECTION OF IONIC MERCURY AT BORON-DOPED DIAMOND ELECTRODES. ANAL LETT 2002. [DOI: 10.1081/al-120002535] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
15
|
Mikkelsen Ø, Schrøder KH. An Oscillating and Renewing Silver Electrode for Cadmium and Lead Detection in Differential Pulse Stripping Voltammetry. ELECTROANAL 2001. [DOI: 10.1002/1521-4109(200105)13:8/9<687::aid-elan687>3.0.co;2-s] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
16
|
Faller C, Stojko N, Henze G, Brainina K. Stripping voltammetric determination of mercury at modified solid electrodes. Anal Chim Acta 1999. [DOI: 10.1016/s0003-2670(99)00434-1] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
17
|
Watson CM, Dwyer DJ, Andle JC, Bruce AE, Bruce MRM. Stripping Analyses of Mercury Using Gold Electrodes: Irreversible Adsorption of Mercury. Anal Chem 1999; 71:3181-6. [DOI: 10.1021/ac981312b] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
18
|
Bertocchi P, Ciranni E, Compagnone D, Magearu V, Palleschi G, Pirvutoiu S, Valvo L. Flow injection analysis of mercury(II) in pharmaceuticals based on enzyme inhibition and biosensor detection. J Pharm Biomed Anal 1999; 20:263-9. [PMID: 10704031 DOI: 10.1016/s0731-7085(99)00032-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
An enzymatic amperometric procedure for measurement of mercury(II) in pharmaceuticals, based on the inhibition of invertase and on a glucose electrode was studied. Analytical parameters for measurements in batch and flow injection analysis (FIA) have been optimised. Mercury(II) was detected in the 10-60 ppb range with RSD < or =2%. A sample throughput of 6 h(-1) for batch and 15 h(-1) for FIA was obtained. The total mercury(II) from thimerosal (thiomersal, sodium ethylmercurithiosalicylate) in eye-drop samples was measured with the amperometric procedure after oxidative cleavage treatment. Results for both batch and FIA procedures correlated well with atomic absorbtion spectroscopy (AAS) data.
Collapse
Affiliation(s)
- P Bertocchi
- Laboratorio di Chimica del Farmaco, Istituto Superiore di Sanita, Rome, Italy
| | | | | | | | | | | | | |
Collapse
|
19
|
Application of Cold Vapor Differential Pulse Voltammetric Method for Determination of Mercury in Urine Samples. Microchem J 1997. [DOI: 10.1006/mchj.1997.1492] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|