1
|
Liu Y, Xu S, Deng Y, Luo J, Zhang K, Yang Y, Sha L, Hu R, Xu Z, Yin E, Xu Q, Wu Y, Cai X. SWCNTs/PEDOT:PSS nanocomposites-modified microelectrode arrays for revealing locking relations between burst and local field potential in cultured cortical networks. Biosens Bioelectron 2024; 253:116168. [PMID: 38452571 DOI: 10.1016/j.bios.2024.116168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/04/2024] [Accepted: 02/23/2024] [Indexed: 03/09/2024]
Abstract
Burst and local field potential (LFP) are fundamental components of brain activity, representing fast and slow rhythms, respectively. Understanding the intricate relationship between burst and LFP is crucial for deciphering the underlying mechanisms of brain dynamics. In this study, we fabricated high-performance microelectrode arrays (MEAs) using the SWCNTs/PEDOT:PSS nanocomposites, which exhibited favorable electrical properties (low impedance: 12.8 ± 2.44 kΩ) and minimal phase delay (-11.96 ± 1.64°). These MEAs enabled precise exploration of the burst-LFP interaction in cultured cortical networks. After a 14-day period of culture, we used the MEAs to monitor electrophysiological activities and revealed a time-locking relationship between burst and LFP, indicating the maturation of the neural network. To further investigate this relationship, we modulated burst firing patterns by treating the neural culture with increasing concentrations of glycine. The results indicated that glycine effectively altered burst firing patterns, with both duration and spike count increasing as the concentration rose. This was accompanied by an enhanced level of time-locking between burst and LFP but a decrease in synchrony among neurons. This study not only highlighted the pivotal role of SWCNTs/PEDOT:PSS-modified MEAs in elucidating the interaction between burst and LFP, bridging the gap between slow and fast brain rhythms in vitro but also provides valuable insights into the potential therapeutic strategies targeting neurological disorders associated with abnormal rhythm generation.
Collapse
Affiliation(s)
- Yaoyao Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Shihong Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Yu Deng
- State Key Laboratory of Common Mechanism Research for Major Diseases, Institute of Basic Medical Sciences Chinese Academy of Medical Sciences, School of Basic Medicine Peking Union Medical College, Beijing, 100005, China
| | - Jinping Luo
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Kui Zhang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Yan Yang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Longze Sha
- State Key Laboratory of Common Mechanism Research for Major Diseases, Institute of Basic Medical Sciences Chinese Academy of Medical Sciences, School of Basic Medicine Peking Union Medical College, Beijing, 100005, China
| | - Ruilin Hu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Zhaojie Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China
| | - Erwei Yin
- Tianjin Artificial Intelligence Innovation Center (TAIIC), Tianjin, 300450, China
| | - Qi Xu
- State Key Laboratory of Common Mechanism Research for Major Diseases, Institute of Basic Medical Sciences Chinese Academy of Medical Sciences, School of Basic Medicine Peking Union Medical College, Beijing, 100005, China.
| | - Yirong Wu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China.
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Science, Beijing, 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100149, China.
| |
Collapse
|
2
|
Schmidt S, Li W, Schubert M, Binnewerg B, Prönnecke C, Zitzmann FD, Bulst M, Wegner S, Meier M, Guan K, Jahnke HG. Novel high-dense microelectrode array based multimodal bioelectronic monitoring system for cardiac arrhythmia re-entry analysis. Biosens Bioelectron 2024; 252:116120. [PMID: 38394704 DOI: 10.1016/j.bios.2024.116120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/26/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024]
Abstract
In recent decades, significant progress has been made in the treatment of heart diseases, particularly in the field of personalized medicine. Despite the development of genetic tests, phenotyping and risk stratification are performed based on clinical findings and invasive in vivo techniques, such as stimulation conduction mapping techniques and programmed ventricular pacing. Consequently, label-free non-invasive in vitro functional analysis systems are urgently needed for more accurate and effective in vitro risk stratification, model-based therapy planning, and clinical safety profile evaluation of drugs. To overcome these limitations, a novel multilayer high-density microelectrode array (HD-MEA), with an optimized configuration of 512 sensing and 4 pacing electrodes on a sensor area of 100 mm2, was developed for the bioelectronic detection of re-entry arrhythmia patterns. Together with a co-developed front-end, we monitored label-free and in parallel cardiac electrophysiology based on field potential monitoring and mechanical contraction using impedance spectroscopy at the same microelectrode. In proof of principle experiments, human induced pluripotent stem cell (hiPS)-derived cardiomyocytes were cultured on HD-MEAs and used to demonstrate the sensitive quantification of contraction strength modulation by cardioactive drugs such as blebbistatin (IC50 = 4.2 μM), omecamtiv and levosimendan. Strikingly, arrhythmia-typical rotor patterns (re-entry) can be induced by optimized electrical stimulation sequences and detected with high spatial resolution. Therefore, we provide a novel cardiac re-entry analysis system as a promising reference point for diagnostic approaches based on in vitro assays using patient-specific hiPS-derived cardiomyocytes.
Collapse
Affiliation(s)
- Sabine Schmidt
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany
| | - Wener Li
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Mario Schubert
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Björn Binnewerg
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Christoph Prönnecke
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany
| | - Franziska D Zitzmann
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany
| | - Martin Bulst
- Sciospec Scientific Instruments GmbH, Leipziger Str. 43b, D-04828, Bennewitz, Germany
| | - Sebastian Wegner
- Sciospec Scientific Instruments GmbH, Leipziger Str. 43b, D-04828, Bennewitz, Germany
| | - Matthias Meier
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany; Helmholtz Pioneer Campus, Helmholtz Zentrum Munich, Neuherberg, Germany
| | - Kaomei Guan
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Heinz-Georg Jahnke
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany.
| |
Collapse
|
3
|
Song SS, Druschel LN, Conard JH, Wang JJ, Kasthuri NM, Ricky Chan E, Capadona JR. Depletion of complement factor 3 delays the neuroinflammatory response to intracortical microelectrodes. Brain Behav Immun 2024; 118:221-235. [PMID: 38458498 DOI: 10.1016/j.bbi.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/26/2024] [Accepted: 03/02/2024] [Indexed: 03/10/2024] Open
Abstract
The neuroinflammatory response to intracortical microelectrodes (IMEs) used with brain-machine interfacing (BMI) applications is regarded as the primary contributor to poor chronic performance. Recent developments in high-plex gene expression technologies have allowed for an evolution in the investigation of individual proteins or genes to be able to identify specific pathways of upregulated genes that may contribute to the neuroinflammatory response. Several key pathways that are upregulated following IME implantation are involved with the complement system. The complement system is part of the innate immune system involved in recognizing and eliminating pathogens - a significant contributor to the foreign body response against biomaterials. Specifically, we have identified Complement 3 (C3) as a gene of interest because it is the intersection of several key complement pathways. In this study, we investigated the role of C3 in the IME inflammatory response by comparing the neuroinflammatory gene expression at the microelectrode implant site between C3 knockout (C3-/-) and wild-type (WT) mice. We have found that, like in WT mice, implantation of intracortical microelectrodes in C3-/- mice yields a dramatic increase in the neuroinflammatory gene expression at all post-surgery time points investigated. However, compared to WT mice, C3 depletion showed reduced expression of many neuroinflammatory genes pre-surgery and 4 weeks post-surgery. Conversely, depletion of C3 increased the expression of many neuroinflammatory genes at 8 weeks and 16 weeks post-surgery, compared to WT mice. Our results suggest that C3 depletion may be a promising therapeutic target for acute, but not chronic, relief of the neuroinflammatory response to IME implantation. Additional compensatory targets may also be required for comprehensive long-term reduction of the neuroinflammatory response for improved intracortical microelectrode performance.
Collapse
Affiliation(s)
- Sydney S Song
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH 44106, United States.
| | - Lindsey N Druschel
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH 44106, United States.
| | - Jacob H Conard
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States.
| | - Jaime J Wang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH 44106, United States.
| | - Niveda M Kasthuri
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH 44106, United States.
| | - E Ricky Chan
- Cleveland Institute for Computational Biology, Case Western Reserve University, Cleveland, OH 44106, United States.
| | - Jeffrey R Capadona
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH 44106, United States.
| |
Collapse
|
4
|
Huang S, Liu X, Lin S, Glynn C, Felix K, Sahasrabudhe A, Maley C, Xu J, Chen W, Hong E, Crosby AJ, Wang Q, Rao S. Control of polymers' amorphous-crystalline transition enables miniaturization and multifunctional integration for hydrogel bioelectronics. Nat Commun 2024; 15:3525. [PMID: 38664445 DOI: 10.1038/s41467-024-47988-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 04/17/2024] [Indexed: 04/28/2024] Open
Abstract
Soft bioelectronic devices exhibit motion-adaptive properties for neural interfaces to investigate complex neural circuits. Here, we develop a fabrication approach through the control of metamorphic polymers' amorphous-crystalline transition to miniaturize and integrate multiple components into hydrogel bioelectronics. We attain an about 80% diameter reduction in chemically cross-linked polyvinyl alcohol hydrogel fibers in a fully hydrated state. This strategy allows regulation of hydrogel properties, including refractive index (1.37-1.40 at 480 nm), light transmission (>96%), stretchability (139-169%), bending stiffness (4.6 ± 1.4 N/m), and elastic modulus (2.8-9.3 MPa). To exploit the applications, we apply step-index hydrogel optical probes in the mouse ventral tegmental area, coupled with fiber photometry recordings and social behavioral assays. Additionally, we fabricate carbon nanotubes-PVA hydrogel microelectrodes by incorporating conductive nanomaterials in hydrogel for spontaneous neural activities recording. We enable simultaneous optogenetic stimulation and electrophysiological recordings of light-triggered neural activities in Channelrhodopsin-2 transgenic mice.
Collapse
Affiliation(s)
- Sizhe Huang
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Xinyue Liu
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, USA
| | - Shaoting Lin
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI, USA
| | - Christopher Glynn
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Kayla Felix
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Atharva Sahasrabudhe
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Collin Maley
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Jingyi Xu
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Weixuan Chen
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Eunji Hong
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA
| | - Alfred J Crosby
- Department of Polymer Science and Engineering, University of Massachusetts, Amherst, MA, USA
| | - Qianbin Wang
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA.
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA.
| | - Siyuan Rao
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA.
- Department of Biomedical Engineering, University of Massachusetts, Amherst, MA, USA.
| |
Collapse
|
5
|
Wang X, Lu T, Cai Z, Han D, Ye X, Liu Z. A Photoelectrochemical Sensor for Real-Time Monitoring of Neurochemical Signals in the Brain of Awake Animals. Anal Chem 2024; 96:6079-6088. [PMID: 38563576 DOI: 10.1021/acs.analchem.4c00934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Metal ion homeostasis is imperative for normal functioning of the brain. Considering the close association between brain metal ions and various pathological processes in brain diseases, it becomes essential to track their dynamics in awake animals for accurate physiological insights. Although ion-selective microelectrodes (ISMEs) have demonstrated great advantage in recording ion signals in awake animals, their intrinsic potential drift impairs their accuracy in long-term in vivo analysis. This study addresses the challenge by integrating ISMEs with photoelectrochemical (PEC) sensing, presenting an excitation-detection separated PEC platform based on potential regulation of ISMEs. A flexible indium tin oxide (Flex-ITO) electrode, modified with MoS2 nanosheets and Au NPs, serves as the photoelectrode and is integrated with a micro-LED. The integrated photoelectrode is placed on the rat skull to remain unaffected by animal activity. The potential of ISME dependent on the concentration of target K+ serves as the modulator of the photocurrent signal of the photoelectrode. The proposed design allows deep brain detection while minimizing interference with neurons, thus enabling real-time monitoring of neurochemical signals in awake animals. It successfully monitors changes in extracellular K+ levels in the rat brain after exposure to PM2.5, presenting a valuable analytical tool for understanding the impact of environmental factors on the nervous system.
Collapse
Affiliation(s)
- Xiao Wang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Tao Lu
- College of Health Science and Engineering, Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Wuhan 430062, China
| | - Zirui Cai
- College of Health Science and Engineering, Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Wuhan 430062, China
| | - Dongfang Han
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Xiaoxue Ye
- College of Health Science and Engineering, Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Wuhan 430062, China
| | - Zhihong Liu
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
- College of Health Science and Engineering, Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Wuhan 430062, China
| |
Collapse
|
6
|
Jamalzadeh M, Cuniberto E, Huang Z, Feeley RM, Patel JC, Rice ME, Uichanco J, Shahrjerdi D. Toward robust quantification of dopamine and serotonin in mixtures using nano-graphitic carbon sensors. Analyst 2024; 149:2351-2362. [PMID: 38375597 DOI: 10.1039/d3an02086j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
Monitoring the coordinated signaling of dopamine (DA) and serotonin (5-HT) is important for advancing our understanding of the brain. However, the co-detection and robust quantification of these signals at low concentrations is yet to be demonstrated. Here, we present the quantification of DA and 5-HT using nano-graphitic (NG) sensors together with fast-scan cyclic voltammetry (FSCV) employing an engineered N-shape potential waveform. Our method yields 6% error in quantifying DA and 5-HT analytes present in in vitro mixtures at concentrations below 100 nM. This advance is due to the electrochemical properties of NG sensors which, in combination with the engineered FSCV waveform, provided distinguishable cyclic voltammograms (CVs) for DA and 5-HT. We also demonstrate the generalizability of the prediction model across different NG sensors, which arises from the consistent voltammetric fingerprints produced by our NG sensors. Curiously, the proposed engineered waveform also improves the distinguishability of DA and 5-HT CVs obtained from traditional carbon fiber (CF) microelectrodes. Nevertheless, this improved distinguishability of CVs obtained from CF is inferior to that of NG sensors, arising from differences in the electrochemical properties of the sensor materials. Our findings demonstrate the potential of NG sensors and our proposed FSCV waveform for future brain studies.
Collapse
Affiliation(s)
- Moeid Jamalzadeh
- Electrical and Computer Engineering Department, New York University, Brooklyn, NY 11201, USA.
| | - Edoardo Cuniberto
- Electrical and Computer Engineering Department, New York University, Brooklyn, NY 11201, USA.
| | - Zhujun Huang
- Electrical and Computer Engineering Department, New York University, Brooklyn, NY 11201, USA.
| | - Ryan M Feeley
- Department of Neurosurgery, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Jyoti C Patel
- Department of Neurosurgery, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Margaret E Rice
- Department of Neurosurgery, New York University Grossman School of Medicine, New York, NY 10016, USA
- Department of Neuroscience and Physiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Joline Uichanco
- Ross School of Business, University of Michigan, Ann Arbor, MI, 48109, USA.
| | - Davood Shahrjerdi
- Electrical and Computer Engineering Department, New York University, Brooklyn, NY 11201, USA.
| |
Collapse
|
7
|
Corna A, Cojocaru AE, Bui MT, Werginz P, Zeck G. Avoidance of axonal stimulation with sinusoidal epiretinal stimulation. J Neural Eng 2024; 21:026036. [PMID: 38547529 DOI: 10.1088/1741-2552/ad38de] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 03/28/2024] [Indexed: 04/11/2024]
Abstract
Objective.Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies.Approach.RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested inex-vivophotoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution.Main results.We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23µA (corresponding to 17.3µC cm-2) at 40 Hz and up to a stimulation amplitude of 0.28µA (14.8µC cm-2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles.Significance.Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.
Collapse
Affiliation(s)
- Andrea Corna
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | | | - Mai Thu Bui
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Paul Werginz
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Günther Zeck
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| |
Collapse
|
8
|
Jiang H, Liu X, Jia YK, Wang YQ, Li W, Wang JD. Electrochemical Monitoring of Sphingosine-1-phosphate-Induced ATP Release Using a Microsensor Based on an Entropy-Driven Bipedal DNA Walker. Anal Chem 2024; 96:5719-5726. [PMID: 38544485 DOI: 10.1021/acs.analchem.4c00964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
Neuropathic pain is a chronic and severe syndrome for which effective therapy is insufficient and the release of ATP from microglia induced by sphingosine-1-phosphate (S1P) plays a vital role in neuropathic pain. Therefore, there is an urgent demand to develop highly sensitive and selective ATP biosensors for quantitative monitoring of low-concentration ATP in the complex nervous system, which helps in understanding the mechanism involved in neuropathic pain. Herein, we developed an electrochemical microsensor based on an entropy-driven bipedal DNA walker. First, the microsensor specifically recognized ATP via ATP aptamers, initiating the entropy-driven bipedal DNA walker. Subsequently, the bipedal DNA walker autonomously traversed the microelectrode interface, introducing methylene blue to the electrode surface and achieving cascade signal amplification. This microsensor showed excellent selectivity, stability, and a low limit of detection at 1.13 nM. The S1P-induced ATP release from BV2 cells was successfully monitored, and it was observed that dicumarol could inhibit this release, suggesting dicumarol as a potential treatment for neuropathic pain. The microsensor's small size exhibited significant potential for monitoring ATP level changes in neuropathic pain in vivo, which provides a new strategy for in situ and quantitative monitoring of nonelectroactive biomolecules associated with neurological diseases.
Collapse
Affiliation(s)
- Hong Jiang
- State Key Laboratory of Metastable Materials Science and Technology, Nano-biotechnology Key Lab of Hebei Province, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
| | - Xiao Liu
- State Key Laboratory of Metastable Materials Science and Technology, Nano-biotechnology Key Lab of Hebei Province, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
| | - Yu-Kang Jia
- State Key Laboratory of Metastable Materials Science and Technology, Nano-biotechnology Key Lab of Hebei Province, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
| | - Ya-Qin Wang
- State Key Laboratory of Metastable Materials Science and Technology, Nano-biotechnology Key Lab of Hebei Province, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
| | - Wei Li
- State Key Laboratory of Metastable Materials Science and Technology, Nano-biotechnology Key Lab of Hebei Province, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
| | - Ji-Dong Wang
- State Key Laboratory of Metastable Materials Science and Technology, Nano-biotechnology Key Lab of Hebei Province, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
| |
Collapse
|
9
|
Zhang Y, Lin T, Han M, Hu M, Xu Y, Huang W, Xiao F, Zhao A. A microelectrode electrochemical sensing platform based on heteroatoms doped carbon nanotubes arrays with peroxidase-like activity for in-situ detection in live cell. Anal Chim Acta 2024; 1297:342386. [PMID: 38438231 DOI: 10.1016/j.aca.2024.342386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 02/05/2024] [Accepted: 02/17/2024] [Indexed: 03/06/2024]
Abstract
In this work, we developed a new strategy to fabricate a series of transition metallic nanoparticles (NPs) embedded on B, N co-doped carbon nanotubes (CNTs) arrays modified flexible carbon fiber electrodes (M@BNCNTs/CF, M = Co, Fe, Ni) via facile inkjet printing assisted with chemical vapor deposition using Ionic liquid as solvent of printing ink and heteroatom dopants. Furthermore, Pt NPs via impregnation-thermal reduction process was anchored on the surface of Co@BNCNTs/CF (Pt-Co@BNCNTs/CF), which holds enhanced peroxidase-like activity and could be directly used as freestanding electrode to detect H2O2, exhibiting a low detection limit of 0.19 μM with wide linear range (0.5 μM-9.4 mM), and high sensitivity (1679 μA cm-2 mM-1). The excellent sensing performance of Pt-Co@BNCNTs/CF is attributed to the Pt, Co NPs anchored on CNTs with great catalytic activity, and the doping B, N would cause graphitic carbon with more defects to improve its inherent reactivity toward H2O2. Besides, CNTs arrays with high surface area also enlarge the exposure of active sites. Moreover, the Pt-Co@NBCNTs/CF microelectrode has been successfully applied in monitoring H2O2 secreted from human colonic cancer cells and normal colonic epithelial cells, which could offer crucial data for distinguishing various cell types and identifying cancer cells from normal cells. This work opens a new horizon to fabricate flexible miniaturized sensing device for extracellular analysis and offers an extended strategy to fabricate other metallic NPs embedded in heteroatoms doped CNTs functionalized flexible fiber electrode, by choosing diverse metal ions and ILs as inkjet printing precursors.
Collapse
Affiliation(s)
- Yan Zhang
- Glyn O. Phillips Hydrocolloid Research Centre, National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering of Ministry of Education, Key Laboratory of Industrial Microbiology in Hubei Province, Department of Bioengineering and Food Science, Hubei University of Technology, Wuhan, 430068, China.
| | - Tao Lin
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Huazhong University of Science and Technology), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Minghui Han
- Glyn O. Phillips Hydrocolloid Research Centre, National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering of Ministry of Education, Key Laboratory of Industrial Microbiology in Hubei Province, Department of Bioengineering and Food Science, Hubei University of Technology, Wuhan, 430068, China
| | - Min Hu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Huazhong University of Science and Technology), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yun Xu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Huazhong University of Science and Technology), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Wei Huang
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Huazhong University of Science and Technology), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Fei Xiao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Huazhong University of Science and Technology), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Anshun Zhao
- Henan Key Laboratory of Cancer Epigenetics, Cancer Institute, The First Affiliated Hospital, and College of Clinical Medicine, Henan University of Science and Technology, Luoyang, 471003, China.
| |
Collapse
|
10
|
McNamara IN, Wellman SM, Li L, Eles JR, Savya S, Sohal HS, Angle MR, Kozai TDY. Electrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays. J Neural Eng 2024; 21:026030. [PMID: 38518365 DOI: 10.1088/1741-2552/ad36e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 03/22/2024] [Indexed: 03/24/2024]
Abstract
Objective. Over the past decade, neural electrodes have played a crucial role in bridging biological tissues with electronic and robotic devices. This study focuses on evaluating the optimal tip profile and insertion speed for effectively implanting Paradromics' high-density fine microwire arrays (FμA) prototypes into the primary visual cortex (V1) of mice and rats, addressing the challenges associated with the 'bed-of-nails' effect and tissue dimpling.Approach. Tissue response was assessed by investigating the impact of electrodes on the blood-brain barrier (BBB) and cellular damage, with a specific emphasis on tailored insertion strategies to minimize tissue disruption during electrode implantation.Main results.Electro-sharpened arrays demonstrated a marked reduction in cellular damage within 50μm of the electrode tip compared to blunt and angled arrays. Histological analysis revealed that slow insertion speeds led to greater BBB compromise than fast and pneumatic methods. Successful single-unit recordings validated the efficacy of the optimized electro-sharpened arrays in capturing neural activity.Significance.These findings underscore the critical role of tailored insertion strategies in minimizing tissue damage during electrode implantation, highlighting the suitability of electro-sharpened arrays for long-term implant applications. This research contributes to a deeper understanding of the complexities associated with high-channel-count microelectrode array implantation, emphasizing the importance of meticulous assessment and optimization of key parameters for effective integration and minimal tissue disruption. By elucidating the interplay between insertion parameters and tissue response, our study lays a strong foundation for the development of advanced implantable devices with a reduction in reactive gliosis and improved performance in neural recording applications.
Collapse
Affiliation(s)
- Ingrid N McNamara
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Steven M Wellman
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Lehong Li
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - James R Eles
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Sajishnu Savya
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | | | | | - Takashi D Y Kozai
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
- Center of the Basis of Neural Cognition, Pittsburgh, PA, United States of America
- McGowan Institute of Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States of America
- NeuroTech Center, University of Pittsburgh Brain Institute, Pittsburgh, PA, United States of America
| |
Collapse
|
11
|
López L, Lozano K, Cruz J, Flores K, Fernández-Vega L, Cunci L. Measurement of neuropeptide Y with molecularly imprinted polypyrrole on carbon fiber microelectrodes. Neuropeptides 2024; 104:102413. [PMID: 38335798 PMCID: PMC10940184 DOI: 10.1016/j.npep.2024.102413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/24/2024] [Accepted: 02/03/2024] [Indexed: 02/12/2024]
Abstract
The measurement of neuropeptides using small electrodes for high spatial resolution would provide us with localized information on the release of neuromolecules. The release of Neuropeptide Y (NPY) is related to different neurological diseases such as stress, obesity, and PTSD, among others. In this conference paper, we electrodeposited polypyrrole on carbon fiber microelectrodes in the presence of NPY to develop a molecularly imprinted polypyrrole sensitive to NPY. Optimization of the electrodeposition process resulted in the full coverage of the polymer with nucleation sites on the carbon fiber ridges, achieving completion by the seventh cycle. Electrodeposition was performed for five cycles, and using cyclic voltammetry (CV), we studied the change in the oxidation current peak for polypyrrole due to the presence of NPY. We also observed a change in capacitance due to the presence of NPY, which was studied by electrochemical impedance spectroscopy (EIS). A linear correlation was found between the oxidation peak and the concentration of NPY between 50 ng/mL and 1000 ng/mL. In addition, a linear correlation was also found between microelectrode capacitance and the concentration of NPY between 50 ng/mL and 1000 ng/mL at 100 kHz.
Collapse
Affiliation(s)
- Luis López
- Department of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States
| | - Kelly Lozano
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States
| | - John Cruz
- Department of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States
| | - Krystal Flores
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States
| | - Lauren Fernández-Vega
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States
| | - Lisandro Cunci
- Department of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States.
| |
Collapse
|
12
|
Verlaat L, Rijks N, Dilai J, Admiraal M, Beudel M, de Bie RM, van der Zwaag W, Schuurman R, van den Munckhof P, Bot M. 7-Tesla Magnetic Resonance Imaging Scanning in Deep Brain Stimulation for Parkinson's Disease: Improving Visualization of the Dorsolateral Subthalamic Nucleus. Mov Disord Clin Pract 2024; 11:373-380. [PMID: 38385792 PMCID: PMC10982587 DOI: 10.1002/mdc3.13982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 12/14/2023] [Accepted: 01/05/2024] [Indexed: 02/23/2024] Open
Abstract
BACKGROUND Identifying the dorsolateral subthalamic nucleus (STN) for deep brain stimulation (DBS) in Parkinson's disease (PD) can be challenging due to the size and double-oblique orientation. Since 2015 we implemented 7-Tesla T2 weighted magnetic resonance imaging (7 T T2) for improving visualization and targeting of the dorsolateral STN. We describe the changes in surgical planning and outcome since implementation of 7 T T2 for DBS in PD. METHODS By comparing two cohorts of STN DBS patients in different time periods we evaluated the influence of 7 T T2 on STN target planning, the number of microelectrode recording (MER) trajectories, length of STN activity and the postoperative motor (UPDRS) improvement. RESULTS From February 2007 to January 2014, 1.5 and 3-Tesla T2 guided STN DBS with 3 MER channels was performed in 76 PD patients. Average length of recorded STN activity in the definite electrode trajectory was 3.9 ± 1.5 mm. From January 2015 to January 2022 7 T T2 and MER-guided STN DBS was performed in 182 PD patients. Average length of recorded STN activity in the definite electrode trajectory was 5.1 ± 1.3 mm and used MER channels decreased from 3 to 1. Average UPDRS improvement was comparable. CONCLUSION Implementation of 7 T T2 for STN DBS enabled a refinement in targeting. Combining classical DBS targeting with dorsolateral STN alignment may be used to determine the optimal trajectory. The improvement in dorsolateral STN visualization can be used for further target refinements, for example adding probabilistic subthalamic connectivity, to enhance clinical outcome of STN DBS.
Collapse
Affiliation(s)
- Lisa Verlaat
- Department of NeurosurgeryUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Niels Rijks
- Department of NeurosurgeryUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - José Dilai
- Department of Neurology and Clinical NeurophysiologyUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Marjolein Admiraal
- Department of Neurology and Clinical NeurophysiologyUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Martijn Beudel
- Department of Neurology and Clinical NeurophysiologyUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Rob M.A. de Bie
- Department of Neurology and Clinical NeurophysiologyUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Wietske van der Zwaag
- Spinoza Centre for Neuroimaging, Royal Netherlands Academy of Arts and SciencesAmsterdamthe Netherlands
| | - Rick Schuurman
- Department of NeurosurgeryUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Pepijn van den Munckhof
- Department of NeurosurgeryUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| | - Maarten Bot
- Department of NeurosurgeryUniversity Medical Centers, Academic Medical CenterAmsterdamthe Netherlands
| |
Collapse
|
13
|
Hayase J, Salama G. A Catheter With a View: Characterizing the Conventional and Microelectrode Intracardiac "Field of View". JACC Clin Electrophysiol 2024; 10:651-653. [PMID: 38520435 DOI: 10.1016/j.jacep.2024.102336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 01/28/2024] [Indexed: 03/25/2024]
Affiliation(s)
- Justin Hayase
- UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine at UCLA, Los Angeles, California, USA.
| | - Guy Salama
- UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| |
Collapse
|
14
|
Abu Shihada J, Jung M, Decke S, Koschinski L, Musall S, Rincón Montes V, Offenhäusser A. Highly Customizable 3D Microelectrode Arrays for In Vitro and In Vivo Neuronal Tissue Recordings. Adv Sci (Weinh) 2024; 11:e2305944. [PMID: 38240370 PMCID: PMC10987114 DOI: 10.1002/advs.202305944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/05/2023] [Indexed: 02/16/2024]
Abstract
Planar microelectrode arrays (MEAs) for - in vitro or in vivo - neuronal signal recordings lack the spatial resolution and sufficient signal-to-noise ratio (SNR) required for a detailed understanding of neural network function and synaptic plasticity. To overcome these limitations, a highly customizable three-dimensional (3D) printing process is used in combination with thin film technology and a self-aligned template-assisted electrochemical deposition process to fabricate 3D-printed-based MEAs on stiff or flexible substrates. Devices with design flexibility and physical robustness are shown for recording neural activity in different in vitro and in vivo applications, achieving high-aspect ratio 3D microelectrodes of up to 33:1. Here, MEAs successfully record neural activity in 3D neuronal cultures, retinal explants, and the cortex of living mice, thereby demonstrating the versatility of the 3D MEA while maintaining high-quality neural recordings. Customizable 3D MEAs provide unique opportunities to study neural activity under regular or various pathological conditions, both in vitro and in vivo, and contribute to the development of drug screening and neuromodulation systems that can accurately monitor the activity of large neural networks over time.
Collapse
Affiliation(s)
- J. Abu Shihada
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
- RWTH Aachen University52062AachenGermany
| | - M. Jung
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
- RWTH Aachen University52062AachenGermany
| | - S. Decke
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
| | - L. Koschinski
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
- RWTH Aachen University52062AachenGermany
- Helmholtz Nano Facility (HNF)Forschungszentrum Jülich52428JülichGermany
| | - S. Musall
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
- RWTH Aachen University52062AachenGermany
- Faculty of MedicineInstitute of Experimental Epileptology and Cognition ResearchUniversity of Bonn53127BonnGermany
- University Hospital Bonn53127BonnGermany
| | - V. Rincón Montes
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
| | - A. Offenhäusser
- Institute of Biological Information Processing (IBI‐3) – BioelectronicsForschungszentrum52428JülichGermany
| |
Collapse
|
15
|
Boltcreed E, Ersöz A, Han M, McConnell GC. Short-Term Effects of Gamma Stimulation on Neuroinflammation at the Tissue-Electrode Interface in Motor Cortex. Neuromodulation 2024; 27:500-508. [PMID: 38099883 PMCID: PMC10990794 DOI: 10.1016/j.neurom.2023.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/20/2023] [Accepted: 11/07/2023] [Indexed: 04/05/2024]
Abstract
OBJECTIVES The reliability of long-term neural recordings as therapeutic interventions for motor and sensory disorders is hampered by the brain tissue response. Previous work showed that flickering light at gamma frequencies (ie, 20-50 Hz) causes enhanced microglial recruitment in the visual cortex. The effects of gamma stimulation on glial cells surrounding implanted neural electrodes are not well understood. We hypothesized that invasive stimulation in the gamma frequency band increases microglial recruitment in the short term and reduces astrogliosis at the tissue-electrode interface. MATERIALS AND METHODS Male Long Evans rats were implanted with dual-shank silicon microelectrode arrays into the motor cortex. After implantation, rats received one hour of 40-Hz stimulation at a constant current of 10 μA using charge-balanced, biphasic pulses on one shank, and the other shank served as the nonstimulated control. Postmortem, tissue sections were stained with ectodermal dysplasia 1 (ED1) for activated microglia, glial fibrillary acidic protein (GFAP) for astrocytes, and 4',6-diamidino-2-phenylindole (DAPI) for nonspecific nuclei. Fluorescent intensity and cell number as a function of distance from the tissue-electrode interface were used to quantify all stained sections. RESULTS Fluorescent intensity for ED1 was nearly 40% lower for control than for stimulated sites (0-500 μm away from the implant), indicating increased microglial recruitment to the stimulated site (p < 0.05). Fluorescent intensity for GFAP was >67% higher for control than for stimulated sites (0-500 μm away from the implant), indicating reduced astrogliosis at the stimulated site (p < 0.05). No differences were observed in DAPI-stained sections between conditions. CONCLUSIONS These results suggest that short-term gamma stimulation modulates glial recruitment in the immediate vicinity of the microelectrode. Future studies will investigate the long-term effects of gamma stimulation on glial recruitment at the tissue-electrode interface as a strategy to improve long-term recording reliability.
Collapse
Affiliation(s)
- Emily Boltcreed
- Stevens Institute of Technology, Hoboken, NJ; Semcer Center for Healthcare Innovation, Hoboken, NJ
| | - Alpaslan Ersöz
- Mechanical Engineering Department, Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering, University of Connecticut, Storrs, CT
| | - Martin Han
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT
| | - George C McConnell
- Stevens Institute of Technology, Hoboken, NJ; Semcer Center for Healthcare Innovation, Hoboken, NJ.
| |
Collapse
|
16
|
Ramezani M, Kim JH, Liu X, Ren C, Alothman A, De-Eknamkul C, Wilson MN, Cubukcu E, Gilja V, Komiyama T, Kuzum D. High-density transparent graphene arrays for predicting cellular calcium activity at depth from surface potential recordings. Nat Nanotechnol 2024; 19:504-513. [PMID: 38212523 DOI: 10.1038/s41565-023-01576-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 11/16/2023] [Indexed: 01/13/2024]
Abstract
Optically transparent neural microelectrodes have facilitated simultaneous electrophysiological recordings from the brain surface with the optical imaging and stimulation of neural activity. A remaining challenge is to scale down the electrode dimensions to the single-cell size and increase the density to record neural activity with high spatial resolution across large areas to capture nonlinear neural dynamics. Here we developed transparent graphene microelectrodes with ultrasmall openings and a large, transparent recording area without any gold extensions in the field of view with high-density microelectrode arrays up to 256 channels. We used platinum nanoparticles to overcome the quantum capacitance limit of graphene and to scale down the microelectrode diameter to 20 µm. An interlayer-doped double-layer graphene was introduced to prevent open-circuit failures. We conducted multimodal experiments, combining the recordings of cortical potentials of microelectrode arrays with two-photon calcium imaging of the mouse visual cortex. Our results revealed that visually evoked responses are spatially localized for high-frequency bands, particularly for the multiunit activity band. The multiunit activity power was found to be correlated with cellular calcium activity. Leveraging this, we employed dimensionality reduction techniques and neural networks to demonstrate that single-cell and average calcium activities can be decoded from surface potentials recorded by high-density transparent graphene arrays.
Collapse
Affiliation(s)
- Mehrdad Ramezani
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Jeong-Hoon Kim
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Xin Liu
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Chi Ren
- Department of Neurosciences, University of California San Diego, La Jolla, CA, USA
| | - Abdullah Alothman
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Chawina De-Eknamkul
- Department of NanoEngineering, University of California San Diego, La Jolla, CA, USA
| | - Madison N Wilson
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Ertugrul Cubukcu
- Department of NanoEngineering, University of California San Diego, La Jolla, CA, USA
| | - Vikash Gilja
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA
| | - Takaki Komiyama
- Department of Neurosciences, University of California San Diego, La Jolla, CA, USA
| | - Duygu Kuzum
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, USA.
| |
Collapse
|
17
|
Omara S, Glashan CA, Tofig BJ, Leenknegt L, Dierckx H, Panfilov AV, Beukers HKC, van Waasbergen MH, Tao Q, Stevenson WG, Nielsen JC, Lukac P, Kristiansen SB, van der Geest RJ, Zeppenfeld K. Multisize Electrode Field-of-View: Validation by High Resolution Gadolinium-Enhanced Cardiac Magnetic Resonance. JACC Clin Electrophysiol 2024; 10:637-650. [PMID: 38276927 DOI: 10.1016/j.jacep.2023.12.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 12/01/2023] [Accepted: 12/04/2023] [Indexed: 01/27/2024]
Abstract
BACKGROUND Voltage mapping to detect ventricular scar is important for guiding catheter ablation, but the field-of-view of unipolar, bipolar, conventional, and microelectrodes as it relates to the extent of viable myocardium (VM) is not well defined. OBJECTIVES The purpose of this study was to evaluate electroanatomic voltage-mapping (EAVM) with different-size electrodes for identifying VM, validated against high-resolution ex-vivo cardiac magnetic resonance (HR-LGE-CMR). METHODS A total of 9 swine with early-reperfusion myocardial infarction were mapped with the QDOT microcatheter. HR-LGE-CMR (0.3-mm slices) were merged with EAVM. At each EAVM point, the underlying VM in multisize transmural cylinders and spheres was quantified from ex vivo CMR and related to unipolar and bipolar voltages recorded from conventional and microelectrodes. RESULTS In each swine, 220 mapping points (Q1, Q3: 216, 260 mapping points) were collected. Infarcts were heterogeneous and nontransmural. Unipolar and bipolar voltage increased with VM volumes from >175 mm3 up to >525 mm3 (equivalent to a 5-mm radius cylinder with height >6.69 mm). VM volumes in subendocardial cylinders with 1- or 3-mm depth correlated poorly with all voltages. Unipolar voltages recorded with conventional and microelectrodes were similar (difference 0.17 ± 2.66 mV) and correlated best to VM within a sphere of radius 10 and 8 mm, respectively. Distance-weighting did not improve the correlation. CONCLUSIONS Voltage increases with transmural volume of VM but correlates poorly with small amounts of VM, which limits EAVM in defining heterogeneous scar. Microelectrodes cannot distinguish thin from thick areas of subendocardial VM. The field-of-view for unipolar recordings for microelectrodes and conventional electrodes appears to be 8 to 10 mm, respectively, and unexpectedly similar.
Collapse
Affiliation(s)
- Sharif Omara
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Claire A Glashan
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Bawer J Tofig
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Lore Leenknegt
- Department of Mathematics, KU Leuven campus Kortrijk, Kortrijk, Belgium
| | - Hans Dierckx
- Department of Mathematics, KU Leuven campus Kortrijk, Kortrijk, Belgium
| | | | - Hans K C Beukers
- Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Qian Tao
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - William G Stevenson
- Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Jens C Nielsen
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Peter Lukac
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Steen B Kristiansen
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Rob J van der Geest
- Department of Radiology, Division of Image Processing, Leiden University Medical Center, Leiden, the Netherlands
| | - Katja Zeppenfeld
- Willem Einthoven Center for Cardiac Arrhythmia Research and Management, Leiden, the Netherlands, and Aarhus, Denmark; Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark.
| |
Collapse
|
18
|
Rocca A, Lehner C, Wafula-Wekesa E, Luna E, Fernández-Cornejo V, Abarca-Olivas J, Soto-Sánchez C, Fernández-Jover E, González-López P. Robot-assisted implantation of a microelectrode array in the occipital lobe as a visual prosthesis: technical note. J Neurosurg 2024; 140:1169-1176. [PMID: 37890180 DOI: 10.3171/2023.8.jns23772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 08/22/2023] [Indexed: 10/29/2023]
Abstract
The prospect of direct interaction between the brain and computers has been investigated in recent decades, revealing several potential applications. One of these is sight restoration in profoundly blind people, which is based on the ability to elicit visual perceptions while directly stimulating the occipital cortex. Technological innovation has led to the development of microelectrodes implantable on the brain surface. The feasibility of implanting a microelectrode on the visual cortex has already been shown in animals, with promising results. Current research has focused on the implantation of microelectrodes into the occipital brain of blind volunteers. The technique raises several technical challenges. In this technical note, the authors suggest a safe and effective approach for robot-assisted implantation of microelectrodes in the occipital lobe for sight restoration.
Collapse
Affiliation(s)
- Alessandra Rocca
- 1Department of Neurosurgery, Alicante General University Hospital, Alicante Institute of Health and Biomedical Research (ISABIAL), Alicante, Spain
- 2Department of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Christian Lehner
- 1Department of Neurosurgery, Alicante General University Hospital, Alicante Institute of Health and Biomedical Research (ISABIAL), Alicante, Spain
- 3Department of Neurosurgery, Medical University Graz, Austria
| | - Emmanuel Wafula-Wekesa
- 1Department of Neurosurgery, Alicante General University Hospital, Alicante Institute of Health and Biomedical Research (ISABIAL), Alicante, Spain
- 4Department of Neurosurgery, Tenwek Hospital, Bomet, Kenya
| | - Enrique Luna
- 6Department of Neurosurgery, Elche General University Hospital, Alicante, Spain
| | - Víctor Fernández-Cornejo
- 1Department of Neurosurgery, Alicante General University Hospital, Alicante Institute of Health and Biomedical Research (ISABIAL), Alicante, Spain
| | - Javier Abarca-Olivas
- 1Department of Neurosurgery, Alicante General University Hospital, Alicante Institute of Health and Biomedical Research (ISABIAL), Alicante, Spain
| | - Cristina Soto-Sánchez
- 5Instituto de Bioingeniería, University Miguel Hernández, CIBER-BBN, Elche, Alicante, Spain; and
| | - Eduardo Fernández-Jover
- 5Instituto de Bioingeniería, University Miguel Hernández, CIBER-BBN, Elche, Alicante, Spain; and
| | - Pablo González-López
- 1Department of Neurosurgery, Alicante General University Hospital, Alicante Institute of Health and Biomedical Research (ISABIAL), Alicante, Spain
| |
Collapse
|
19
|
Liggett JE, Gonzalez BC, Lytle DA, Pressman JG, Dionysiou DD, Lee WH, Harmon SM, Wahman DG. Applying microelectrodes to investigate aged ductile iron and copper coupon reactivity during free chlorine application. Water Res 2024; 253:121324. [PMID: 38382294 DOI: 10.1016/j.watres.2024.121324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 01/22/2024] [Accepted: 02/14/2024] [Indexed: 02/23/2024]
Abstract
In drinking water distribution systems, including premise plumbing, dissolved oxygen (DO) and free chlorine (FC) are common oxidants and ductile iron (DI) and copper (Cu) are commonly used pipe materials. Microelectrodes as a tool have been applied in previous corrosion research and were used in this study to collect quantifiable data and understand DO and FC reactivity and pH changes at the water-metal interface. Using microelectrodes, pH, DO, and FC profiles from the bulk water to near and at the surface of aged DI (154-190 d) and Cu (2 d and 86-156 d) coupons were investigated during periods of flow and stagnation (30 min). Using the measured microelectrode profiles, oxidant fluxes and apparent surface reaction rate constants were calculated to elucidate differences between DO and FC reactivity with the coupons. Microelectrodes were successfully applied to measure pH, DO, and FC profiles from the bulk water to near aged DI and Cu coupon surfaces; Cu coupons aged quickly and exhibited less reactivity at 2 d with DO and FC than aged DI coupons did after 154-190 d; and for the aged DI coupon experiments, orthophosphate presence stabilized pH profiles where without orthophosphate pH fluctuations of greater than 2 pH units occurred from the bulk water to the DI coupon surface.
Collapse
Affiliation(s)
- Jennifer E Liggett
- College of Engineering and Applied Science, Department 2600 Clifton Ave, University of Cincinnati, Cincinnati, OH 45220, USA
| | - Beatriz C Gonzalez
- Oak Ridge Institute for Science and Education (ORISE) Post-Doctoral Fellow at U.S. Environmental Protection Agency, Cincinnati, OH 45268, USA
| | - Darren A Lytle
- Center for Environmental Solutions & Emergency Response, U.S. Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268, USA
| | - Jonathan G Pressman
- Center for Environmental Solutions & Emergency Response, U.S. Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268, USA
| | - Dionysios D Dionysiou
- Environmental Engineering Program, University of Cincinnati, Cincinnati, OH 45211, USA
| | - Woo Hyoung Lee
- Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL 32816-2450, USA
| | - Stephen M Harmon
- Center for Environmental Solutions & Emergency Response, U.S. Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268, USA
| | - David G Wahman
- Center for Environmental Solutions & Emergency Response, U.S. Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268, USA.
| |
Collapse
|
20
|
Viana D, Walston ST, Masvidal-Codina E, Illa X, Rodríguez-Meana B, Del Valle J, Hayward A, Dodd A, Loret T, Prats-Alfonso E, de la Oliva N, Palma M, Del Corro E, Del Pilar Bernicola M, Rodríguez-Lucas E, Gener T, de la Cruz JM, Torres-Miranda M, Duvan FT, Ria N, Sperling J, Martí-Sánchez S, Spadaro MC, Hébert C, Savage S, Arbiol J, Guimerà-Brunet A, Puig MV, Yvert B, Navarro X, Kostarelos K, Garrido JA. Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation. Nat Nanotechnol 2024; 19:514-523. [PMID: 38212522 PMCID: PMC11026161 DOI: 10.1038/s41565-023-01570-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 11/07/2023] [Indexed: 01/13/2024]
Abstract
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm-2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Collapse
Affiliation(s)
- Damià Viana
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Steven T Walston
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Eduard Masvidal-Codina
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Xavi Illa
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Campus UAB, Bellaterra, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Madrid, Spain
| | - Bruno Rodríguez-Meana
- Institute of Neurosciences, Department of Cell Biology, Physiology and Immunology, Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Jaume Del Valle
- Institute of Neurosciences, Department of Cell Biology, Physiology and Immunology, Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Universitat Autònoma de Barcelona, Barcelona, Spain
- Secció de Fisiologia, Department de Bioquímica i Fisiologia, Facultat de Farmàcia i Ciències de l'Alimentació, Institut de Neurociències, Universitat de Barcelona, Barcelona, Spain
| | - Andrew Hayward
- Nanomedicine Lab, National Graphene Institute and Faculty of Biology, Medicine & Health, Manchester, UK
| | - Abbie Dodd
- Nanomedicine Lab, National Graphene Institute and Faculty of Biology, Medicine & Health, Manchester, UK
| | - Thomas Loret
- Nanomedicine Lab, National Graphene Institute and Faculty of Biology, Medicine & Health, Manchester, UK
| | - Elisabet Prats-Alfonso
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Campus UAB, Bellaterra, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Madrid, Spain
| | - Natàlia de la Oliva
- Institute of Neurosciences, Department of Cell Biology, Physiology and Immunology, Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Marie Palma
- Univ. Grenoble Alpes, Inserm, U1216, Grenoble Institut Neurosciences, Grenoble, France
| | - Elena Del Corro
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - María Del Pilar Bernicola
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Elisa Rodríguez-Lucas
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
- Hospital del Mar Research Institute, Barcelona, Spain
| | - Thomas Gener
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
- Hospital del Mar Research Institute, Barcelona, Spain
| | - Jose Manuel de la Cruz
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Miguel Torres-Miranda
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Fikret Taygun Duvan
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Nicola Ria
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Justin Sperling
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Sara Martí-Sánchez
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Maria Chiara Spadaro
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Clément Hébert
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
| | - Sinead Savage
- Nanomedicine Lab, National Graphene Institute and Faculty of Biology, Medicine & Health, Manchester, UK
| | - Jordi Arbiol
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
- ICREA, Barcelona, Spain
| | - Anton Guimerà-Brunet
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Campus UAB, Bellaterra, Spain
| | - M Victoria Puig
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain
- Hospital del Mar Research Institute, Barcelona, Spain
| | - Blaise Yvert
- Univ. Grenoble Alpes, Inserm, U1216, Grenoble Institut Neurosciences, Grenoble, France
| | - Xavier Navarro
- Institute of Neurosciences, Department of Cell Biology, Physiology and Immunology, Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Kostas Kostarelos
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain.
- Institute of Neurosciences, Department of Cell Biology, Physiology and Immunology, Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Universitat Autònoma de Barcelona, Barcelona, Spain.
- Nanomedicine Lab, National Graphene Institute and Faculty of Biology, Medicine & Health, Manchester, UK.
| | - Jose A Garrido
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Barcelona, Spain.
- ICREA, Barcelona, Spain.
| |
Collapse
|
21
|
Huan Y, Tibbetts BN, Richie JM, Chestek CA, Chiel HJ. Intracellular neural control of an active feeding structure in Aplysia using a carbon fiber electrode array. J Neurosci Methods 2024; 404:110077. [PMID: 38336092 DOI: 10.1016/j.jneumeth.2024.110077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 01/23/2024] [Accepted: 02/05/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND To study neural control of behavior, intracellular recording and stimulation of many neurons in freely moving animals would be ideal. However, current technologies limit the number of neurons that can be monitored and manipulated. A new technology has become available for intracellular recording and stimulation which we demonstrate in the tractable nervous system of Aplysia. NEW METHOD Carbon fiber electrode arrays (whose tips are coated with platinum-iridium) were used with an in vitro feeding preparation to intracellularly record from and to control the activity of multiple neurons during feeding movements. RESULTS In an in vitro feeding preparation, the carbon fiber electrode arrays recorded action potentials and subthreshold synaptic potentials during feeding movements. Depolarizing or hyperpolarizing currents activated or inhibited identified neurons (respectively), manipulating the movements of the feeding apparatus. COMPARISON WITH EXISTING METHOD(S) Standard glass microelectrodes that are commonly used for intracellular recording are stiff, liable to break in response to movement, and require many micromanipulators to be precisely positioned. In contrast, carbon fiber arrays are less sensitive to movement, but are capable of multiple channels of intracellular recording and stimulation. CONCLUSIONS Carbon fiber arrays are a novel technology for intracellular recording that can be used in moving preparations. They can record both action potentials and synaptic activity in multiple neurons and can be used to stimulate multiple neurons in complex patterns.
Collapse
Affiliation(s)
- Yu Huan
- Department of Biology, Case Western Reserve University, Cleveland, OH 44106-7080, USA
| | - Benjamin N Tibbetts
- Department of Biology, Case Western Reserve University, Cleveland, OH 44106-7080, USA
| | - Julianna M Richie
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Cynthia A Chestek
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Hillel J Chiel
- Department of Biology, Case Western Reserve University, Cleveland, OH 44106-7080, USA; Department of Neuroscience, Case Western Reserve University, Cleveland, OH 44106-7080, USA; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106-7080, USA.
| |
Collapse
|
22
|
Liu H, Wei CM, Feng TY, Dong WX, Xiao C. Research progress on insect visual electrophysiological techniques. Ying Yong Sheng Tai Xue Bao 2024; 35:858-866. [PMID: 38646774 DOI: 10.13287/j.1001-9332.202403.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
Insect visual electrophysiological techniques are important to study the electrical characteristics of photoreceptor cells and visual neurons in insects, including electroretinography (ERG) and microelectrode intracellular recording (MIR). ERG records the changes of voltage or electric current in the retina of insects in response to different light stimuli, which occurs outside the cell. MIR records the changes in individual photoreceptor cells or visual neurons of an insect exposed to different lights, which occurs inside the cell. Insect visual electrophysiological techniques can explore the mechanism of electrophysiological response of insects' vision to light and reveal their sensitive light spectra and photoreceptor types. This review introduced the basic structure and the principle of ERG and MIR, and summarized their applications in insect researches in the past 20 years, which would provide references for elucidating the mechanism of light perception in insects and the use of insect phototropism to control pests.
Collapse
Affiliation(s)
- Hang Liu
- National Key Laboratory for Conservation and Utilization of Bio-Resources, Kunming 650201, China
- College of Plant Protection, Yunnan Agricultural University, Kunming 650201,China
| | - Cheng-Mei Wei
- National Key Laboratory for Conservation and Utilization of Bio-Resources, Kunming 650201, China
- College of Plant Protection, Yunnan Agricultural University, Kunming 650201,China
| | - Tai-Yang Feng
- National Key Laboratory for Conservation and Utilization of Bio-Resources, Kunming 650201, China
- College of Plant Protection, Yunnan Agricultural University, Kunming 650201,China
| | - Wen-Xia Dong
- National Key Laboratory for Conservation and Utilization of Bio-Resources, Kunming 650201, China
- College of Plant Protection, Yunnan Agricultural University, Kunming 650201,China
| | - Chun Xiao
- National Key Laboratory for Conservation and Utilization of Bio-Resources, Kunming 650201, China
- College of Plant Protection, Yunnan Agricultural University, Kunming 650201,China
| |
Collapse
|
23
|
Cho YU, Lee JY, Yu KJ. Integration of in vivo electrophysiology and optogenetics in rodents with PEDOT:PSS neural electrode array. STAR Protoc 2024; 5:102909. [PMID: 38427565 PMCID: PMC10918330 DOI: 10.1016/j.xpro.2024.102909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 12/27/2023] [Accepted: 02/07/2024] [Indexed: 03/03/2024] Open
Abstract
Here, we present a protocol for the fabrication of transparent implantable electrode arrays for integrating optogenetics and electrophysiology. We describe steps for fabricating microelectrodes using the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate). We then detail procedures for analyzing performance of the electrodes and recording light-evoked neural activities from the transgenic mouse. This protocol utilizes photolithography rather than conventional electrodeposition. For complete details on the use and execution of this protocol, please refer to Cho et al. (2022).1.
Collapse
Affiliation(s)
- Young Uk Cho
- School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemungu, Seoul 03722, Republic of Korea
| | - Ju Young Lee
- School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemungu, Seoul 03722, Republic of Korea
| | - Ki Jun Yu
- School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemungu, Seoul 03722, Republic of Korea; School of Electrical and Electronic Engineering, YU-KIST Institute, Yonsei University, 50 Yonsei-ro, Seodaemungu, Seoul 03722, Republic of Korea.
| |
Collapse
|
24
|
Varga I, Bakstein E, Gilmore G, May J, Novak D. Statistical segmentation model for accurate electrode positioning in Parkinson's deep brain stimulation based on clinical low-resolution image data and electrophysiology. PLoS One 2024; 19:e0298320. [PMID: 38483943 PMCID: PMC10939223 DOI: 10.1371/journal.pone.0298320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 01/22/2024] [Indexed: 03/17/2024] Open
Abstract
BACKGROUND Deep Brain Stimulation (DBS), applying chronic electrical stimulation of subcortical structures, is a clinical intervention applied in major neurologic disorders. In order to achieve a good clinical effect, accurate electrode placement is necessary. The primary localisation is typically based on presurgical MRI imaging, often followed by intra-operative electrophysiology recording to increase the accuracy and to compensate for brain shift, especially in cases where the surgical target is small, and there is low contrast: e.g., in Parkinson's disease (PD) and in its common target, the subthalamic nucleus (STN). METHODS We propose a novel, fully automatic method for intra-operative surgical navigation. First, the surgical target is segmented in presurgical MRI images using a statistical shape-intensity model. Next, automated alignment with intra-operatively recorded microelectrode recordings is performed using a probabilistic model of STN electrophysiology. We apply the method to a dataset of 120 PD patients with clinical T2 1.5T images, of which 48 also had available microelectrode recordings (MER). RESULTS The proposed segmentation method achieved STN segmentation accuracy around dice = 0.60 compared to manual segmentation. This is comparable to the state-of-the-art on low-resolution clinical MRI data. When combined with electrophysiology-based alignment, we achieved an accuracy of 0.85 for correctly including recording sites of STN-labelled MERs in the final STN volume. CONCLUSION The proposed method combines image-based segmentation of the subthalamic nucleus with microelectrode recordings to estimate their mutual location during the surgery in a fully automated process. Apart from its potential use in clinical targeting, the method can be used to map electrophysiological properties to specific parts of the basal ganglia structures and their vicinity.
Collapse
Affiliation(s)
- Igor Varga
- Department of Cybernetics, Czech Technical University in Prague, Prague, Czech Republic
- Czech Centre for Phenogenomics, Institute of Molecular Genetics of the Czech Academy of Sciences, Prague, Czech Republic
| | - Eduard Bakstein
- Department of Cybernetics, Czech Technical University in Prague, Prague, Czech Republic
- National Institute of Mental Health, Klecany, Czech Republic
| | - Greydon Gilmore
- Movement Disorder Centre, University Hospital, University of Western Ontario, Ontario, Canada
| | - Jaromir May
- Department of Neurosurgery, Na Homolce Hospital, Prague, Czech Republic
| | - Daniel Novak
- Department of Cybernetics, Czech Technical University in Prague, Prague, Czech Republic
| |
Collapse
|
25
|
Jones PD, Molina-Martínez B, Niedworok A, Cesare P. A microphysiological system for parallelized morphological and electrophysiological read-out of 3D neuronal cell culture. Lab Chip 2024; 24:1750-1761. [PMID: 38348692 DOI: 10.1039/d3lc00963g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
Three-dimensional in vitro models in microfluidic systems are promising tools for studying cell biology, with complex models using multiple cell types combined with high resolution imaging. Neuronal models demand electrical readout of the activity of networks of single neurons, yet classical planar microelectrode arrays struggle to capture extracellular action potentials when neural soma are suspended distant from the microelectrodes. This study introduces sophisticated microfluidic microelectrode arrays, specifically tailored for electrophysiology of 3D neuronal cultures. Using multilayer photolithography of permanent epoxy photoresists, we developed devices having 12 independent culture modules in a convenient format. Each module has two adjacent compartments for hydrogel-based 3D cell culture, with tunnels allowing projection of neurites between compartments. Microelectrodes integrated in the tunnels record action potentials as they pass between the compartments. Mesh ceilings separate the compartments from overlying wells, allowing for simple cell seeding and later nutrient, gas and waste exchange and application of test substances. Using these devices, we have demonstrated 3D neuronal culture, including electrophysiological recording and live imaging. This microphysiological platform will enable high-throughput investigation of neuronal networks for investigation of neurological disorders, neural pharmacology and basic neuroscience. Further models could include cocultures representing multiple brain regions or innervation models of other organs.
Collapse
Affiliation(s)
- Peter D Jones
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany.
| | - Beatriz Molina-Martínez
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany.
| | - Anita Niedworok
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany.
| | - Paolo Cesare
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany.
- Department for Microphysiological Systems, Institute of Biomedical Engineering, Eberhard Karls University Tübingen, 72074 Tübingen, Germany
| |
Collapse
|
26
|
De Falco E, Solcà M, Bernasconi F, Babo-Rebelo M, Young N, Sammartino F, Tallon-Baudry C, Navarro V, Rezai AR, Krishna V, Blanke O. Single neurons in the thalamus and subthalamic nucleus process cardiac and respiratory signals in humans. Proc Natl Acad Sci U S A 2024; 121:e2316365121. [PMID: 38451949 PMCID: PMC10945861 DOI: 10.1073/pnas.2316365121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 01/16/2024] [Indexed: 03/09/2024] Open
Abstract
Visceral signals are constantly processed by our central nervous system, enable homeostatic regulation, and influence perception, emotion, and cognition. While visceral processes at the cortical level have been extensively studied using non-invasive imaging techniques, very few studies have investigated how this information is processed at the single neuron level, both in humans and animals. Subcortical regions, relaying signals from peripheral interoceptors to cortical structures, are particularly understudied and how visceral information is processed in thalamic and subthalamic structures remains largely unknown. Here, we took advantage of intraoperative microelectrode recordings in patients undergoing surgery for deep brain stimulation (DBS) to investigate the activity of single neurons related to cardiac and respiratory functions in three subcortical regions: ventral intermedius nucleus (Vim) and ventral caudalis nucleus (Vc) of the thalamus, and subthalamic nucleus (STN). We report that the activity of a large portion of the recorded neurons (about 70%) was modulated by either the heartbeat, the cardiac inter-beat interval, or the respiration. These cardiac and respiratory response patterns varied largely across neurons both in terms of timing and their kind of modulation. A substantial proportion of these visceral neurons (30%) was responsive to more than one of the tested signals, underlining specialization and integration of cardiac and respiratory signals in STN and thalamic neurons. By extensively describing single unit activity related to cardiorespiratory function in thalamic and subthalamic neurons, our results highlight the major role of these subcortical regions in the processing of visceral signals.
Collapse
Affiliation(s)
- Emanuela De Falco
- Laboratory of Cognitive Neuroscience, School of Life Sciences, Neuro-X Institute and Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne1015, Switzerland
- Department of Neuroscience, Rockefeller Neuroscience Institute–West Virginia University, Morgantown, WV26505
| | - Marco Solcà
- Laboratory of Cognitive Neuroscience, School of Life Sciences, Neuro-X Institute and Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne1015, Switzerland
- Department of Psychiatry, University Hospital Geneva, Geneva1205, Switzerland
| | - Fosco Bernasconi
- Laboratory of Cognitive Neuroscience, School of Life Sciences, Neuro-X Institute and Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne1015, Switzerland
| | - Mariana Babo-Rebelo
- Laboratory of Cognitive Neuroscience, School of Life Sciences, Neuro-X Institute and Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne1015, Switzerland
| | - Nicole Young
- Medical Department, SpecialtyCare, Brentwood, TN37027
| | - Francesco Sammartino
- Department of Physical Medicine and Rehabilitation, The Ohio State University, Columbus, OH43210
| | - Catherine Tallon-Baudry
- Laboratoire de Neurosciences Cognitives et Computationnelles, Département d’Etudes Cognitives, École normale supérieure-Paris Sciences et Lettres University, Inserm, Paris75005, France
| | - Vincent Navarro
- Sorbonne Université, Paris Brain Institute—Institut du Cerveau et de la Moelle épinière, Inserm, CNRS, Assistance Publique - Hôpitaux de Paris, Epilepsy Unit, Hôpital de la Pitié-Salpêtrière, Paris75013, France
| | - Ali R. Rezai
- Department of Neurosurgery, Rockefeller Neuroscience Institute—West Virginia University, Morgantown, WV26505
| | - Vibhor Krishna
- Department of Neurosurgery, University of North Carolina at Chapel Hill, Durham, NC27516
| | - Olaf Blanke
- Laboratory of Cognitive Neuroscience, School of Life Sciences, Neuro-X Institute and Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne1015, Switzerland
- Department of Clinical Neurosciences, University Hospital Geneva, Geneva1205, Switzerland
| |
Collapse
|
27
|
Lefebvre C, Vreulx AC, Dumortier C, Bégard S, Gelle C, Siedlecki-Wullich D, Colin M, Kilinc D, Halliez S. Integration of Microfluidic Devices with Microelectrode Arrays to Functionally Assay Amyloid-β-Induced Synaptotoxicity. ACS Biomater Sci Eng 2024; 10:1856-1868. [PMID: 38385618 DOI: 10.1021/acsbiomaterials.3c00997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Alzheimer's disease (AD) is a neurodegenerative disease and the most frequent cause of dementia. It is characterized by the accumulation in the brain of two pathological protein aggregates: amyloid-β peptides (Aβ) and abnormally phosphorylated tau. The progressive cognitive decline observed in patients strongly correlates with the synaptic loss. Many lines of evidence suggest that soluble forms of Aβ accumulate into the brain where they cause synapse degeneration. Stopping their spreading and/or targeting the pathophysiological mechanisms leading to synaptic loss would logically be beneficial for the patients. However, we are still far from understanding these processes. Our objective was therefore to develop a versatile model to assay and study Aβ-induced synaptotoxicity. We integrated a microfluidic device that physically isolates synapses from presynaptic and postsynaptic neurons with a microelectrode array. We seeded mouse primary cortical cells in the presynaptic and postsynaptic chambers. After functional synapses have formed in the synaptic chamber, we exposed them to concentrated conditioned media from cell lines overexpressing the wild-type or mutated amyloid precursor protein and thus secreting different levels of Aβ. We recorded the neuronal activity before and after exposition to Aβ and quantified Aβ's effects on the connectivity between presynaptic and postsynaptic neurons. We observed that the application of Aβ on the synapses for 48 h strongly decreased the interchamber connectivity without significantly affecting the neuronal activity in the presynaptic or postsynaptic chambers. Thus, through this model, we are able to functionally assay the impact of Aβ peptides (or other molecules) on synaptic connectivity and to use the latter as a proxy to study Aβ-induced synaptotoxicity. Moreover, since the presynaptic, postsynaptic, and synaptic chambers can be individually targeted, our assay provides a powerful tool to evaluate the involvement of candidate genes in synaptic vulnerability and/or test therapeutic strategies for AD.
Collapse
Affiliation(s)
- Camille Lefebvre
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Anaïs-Camille Vreulx
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Corentin Dumortier
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Séverine Bégard
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Carla Gelle
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Dolores Siedlecki-Wullich
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Morvane Colin
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Devrim Kilinc
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Sophie Halliez
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| |
Collapse
|
28
|
Emery BA, Khanzada S, Hu X, Klütsch D, Amin H. Recording and Analyzing Multimodal Large-Scale Neuronal Ensemble Dynamics on CMOS-Integrated High-Density Microelectrode Array. J Vis Exp 2024. [PMID: 38526084 DOI: 10.3791/66473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024] Open
Abstract
Large-scale neuronal networks and their complex distributed microcircuits are essential to generate perception, cognition, and behavior that emerge from patterns of spatiotemporal neuronal activity. These dynamic patterns emerging from functional groups of interconnected neuronal ensembles facilitate precise computations for processing and coding multiscale neural information, thereby driving higher brain functions. To probe the computational principles of neural dynamics underlying this complexity and investigate the multiscale impact of biological processes in health and disease, large-scale simultaneous recordings have become instrumental. Here, a high-density microelectrode array (HD-MEA) is employed to study two modalities of neural dynamics - hippocampal and olfactory bulb circuits from ex-vivo mouse brain slices and neuronal networks from in-vitro cell cultures of human induced pluripotent stem cells (iPSCs). The HD-MEA platform, with 4096 microelectrodes, enables non-invasive, multi-site, label-free recordings of extracellular firing patterns from thousands of neuronal ensembles simultaneously at high spatiotemporal resolution. This approach allows the characterization of several electrophysiological network-wide features, including single/-multi-unit spiking activity patterns and local field potential oscillations. To scrutinize these multidimensional neural data, we have developed several computational tools incorporating machine learning algorithms, automatic event detection and classification, graph theory, and other advanced analyses. By supplementing these computational pipelines with this platform, we provide a methodology for studying the large, multiscale, and multimodal dynamics from cell assemblies to networks. This can potentially advance our understanding of complex brain functions and cognitive processes in health and disease. Commitment to open science and insights into large-scale computational neural dynamics could enhance brain-inspired modeling, neuromorphic computing, and neural learning algorithms. Furthermore, understanding the underlying mechanisms of impaired large-scale neural computations and their interconnected microcircuit dynamics could lead to the identification of specific biomarkers, paving the way for more accurate diagnostic tools and targeted therapies for neurological disorders.
Collapse
Affiliation(s)
- Brett Addison Emery
- Group of "Biohybrid Neuroelectronics (BIONICS)", German Center for Neurodegenerative Diseases (DZNE)
| | - Shahrukh Khanzada
- Group of "Biohybrid Neuroelectronics (BIONICS)", German Center for Neurodegenerative Diseases (DZNE)
| | - Xin Hu
- Group of "Biohybrid Neuroelectronics (BIONICS)", German Center for Neurodegenerative Diseases (DZNE)
| | - Diana Klütsch
- Group of "Biohybrid Neuroelectronics (BIONICS)", German Center for Neurodegenerative Diseases (DZNE)
| | - Hayder Amin
- Group of "Biohybrid Neuroelectronics (BIONICS)", German Center for Neurodegenerative Diseases (DZNE); Faculty of Medicine Carl Gustav Carus, Technical University Dresden; Dresden Center for Intelligent Materials (DCIM), Technical University Dresden;
| |
Collapse
|
29
|
Zheng Z, Grall S, Kim SH, Chovin A, Clement N, Demaille C. Activationless Electron Transfer of Redox-DNA in Electrochemical Nanogaps. J Am Chem Soc 2024; 146:6094-6103. [PMID: 38407938 DOI: 10.1021/jacs.3c13532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
Our recent discovery of decreased reorganization energy in electrode-tethered redox-DNA systems prompts inquiries into the origin of this phenomenon and suggests its potential use to lower the activation energy of electrochemical reactions. Here, we show that the confinement of the DNA chain in a nanogap amplifies this effect to an extent to which it nearly abolishes the intrinsic activation energy of electron transfer. Employing electrochemical atomic force microscopy (AFM-SECM), we create sub-10 nm nanogaps between a planar electrode surface bearing end-anchored ferrocenylated DNA chains and an incoming microelectrode tip. The redox cycling of the DNA's ferrocenyl (Fc) moiety between the surface and the tip generates a measurable current at the scale of ∼10 molecules. Our experimental findings are rigorously interpreted through theoretical modeling and original molecular dynamics simulations (Q-Biol code). Several intriguing findings emerge from our investigation: (i) The electron transport resulting from DNA dynamics is many times faster than predicted by simple diffusion considerations. (ii) The current in the nanogap is solely governed by the electron transfer rate at the electrodes. (iii) This rate rapidly saturates as overpotentials applied to the nanogap electrodes increase, implying near-complete suppression of the reorganization energy for the oxidation/reduction of the Fc heads within confined DNA. Furthermore, evidence is presented that this may constitute a general, previously unforeseen, behavior of redox polymer chains in electrochemical nanogaps.
Collapse
Affiliation(s)
- Zhiyong Zheng
- Université Paris Cité, CNRS, Laboratoire d'Electrochimie Moléculaire, F-75013 Paris, France
| | - Simon Grall
- IIS, LIMMS/CNRS-IIS UMI2820, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, 153-8505 Tokyo, Japan
| | - Soo Hyeon Kim
- IIS, LIMMS/CNRS-IIS UMI2820, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, 153-8505 Tokyo, Japan
| | - Arnaud Chovin
- Université Paris Cité, CNRS, Laboratoire d'Electrochimie Moléculaire, F-75013 Paris, France
| | - Nicolas Clement
- IIS, LIMMS/CNRS-IIS UMI2820, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, 153-8505 Tokyo, Japan
- LAAS, 7 avenue du Colonel Roche, 31400 Toulouse, France
| | - Christophe Demaille
- Université Paris Cité, CNRS, Laboratoire d'Electrochimie Moléculaire, F-75013 Paris, France
| |
Collapse
|
30
|
Haga W, Sekine K, Hamid SA, Imayasu M, Yoshida T, Tsutsui H. Development of artificial synapse organizers liganded with a peptide tag for molecularly inducible neuron-microelectrode interface. Biochem Biophys Res Commun 2024; 699:149563. [PMID: 38277728 DOI: 10.1016/j.bbrc.2024.149563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 01/20/2024] [Indexed: 01/28/2024]
Abstract
It has been proposed that cell-type-specific bioelectronic interfaces for neuronal circuits could be established by utilizing the function of synapse organizers. For this purpose, using neurexin-1β and a peptide tag, we engineered compact synapse organizers that do not interact with the naturally occurring receptors but induce presynaptic differentiation upon contact with nanobody-decorated objects in cultured mammalian and chick forebrain neurons. In chick neurons, the engineered organizer exerted synaptogenesis typically in ∼4 h after the contact, even under an air atmosphere at room temperature, thereby providing a useful cellular model for establishing the molecularly inducible neuron-microelectrode interface.
Collapse
Affiliation(s)
- Wataru Haga
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa, 923-1292, Japan
| | - Kosuke Sekine
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa, 923-1292, Japan
| | - Sm Ahasanul Hamid
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa, 923-1292, Japan
| | - Mieko Imayasu
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa, 923-1292, Japan
| | - Tomoyuki Yoshida
- Department of Molecular Neuroscience, Faculty of Medicine, University of Toyama, Toyama, 930-0194, Japan; Research Center for Idling Brain Science, University of Toyama, Toyama, 930-0194, Japan
| | - Hidekazu Tsutsui
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa, 923-1292, Japan; Division of Transdisciplinary Sciences, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa, 923-1292, Japan.
| |
Collapse
|
31
|
Soft high-density neural probes enable stable single-neuron recordings. Nat Nanotechnol 2024; 19:277-8. [PMID: 38135718 DOI: 10.1038/s41565-023-01546-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
|
32
|
Ernault AC, Al-Shama RFM, Li J, Devalla HD, de Groot JR, Coronel R, Vigmond E, Boukens BJ. Interpretation of field and LEAP potentials recorded from cardiomyocyte monolayers. Am J Physiol Heart Circ Physiol 2024; 326:H800-H811. [PMID: 38180452 DOI: 10.1152/ajpheart.00463.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 12/04/2023] [Accepted: 01/02/2024] [Indexed: 01/06/2024]
Abstract
Multielectrode arrays (MEAs) are the method of choice for electrophysiological characterization of cardiomyocyte monolayers. The field potentials recorded using an MEA are like extracellular electrograms recorded from the myocardium using conventional electrodes. Nevertheless, different criteria are used to interpret field potentials and extracellular electrograms, which hamper correct interpretation and translation to the patient. To validate the criteria for interpretation of field potentials, we used neonatal rat cardiomyocytes to generate monolayers. We recorded field potentials using an MEA and simultaneously recorded action potentials using sharp microelectrodes. In parallel, we recreated our experimental setting in silico and performed simulations. We show that the amplitude of the local RS complex of a field potential correlated with conduction velocity in silico but not in vitro. The peak time of the T wave in field potentials exhibited a strong correlation with APD90 while the steepest upslope correlated well with APD50. However, this relationship only holds when the T wave displayed a biphasic pattern. Next, we simulated local extracellular action potentials (LEAPs). The shape of the LEAP differed markedly from the shape of the local action potential, but the final duration of the LEAP coincided with APD90. Criteria for interpretation of extracellular electrograms should be applied to field potentials. This will provide a strong basis for the analysis of heterogeneity in conduction velocity and repolarization in cultured monolayers of cardiomyocytes. Finally, a LEAP is not a recording of the local action potential but is generated by intracellular current provided by neighboring cardiomyocytes and is superior to field potential duration in estimating APD90.NEW & NOTEWORTHY We present a physiological basis for the interpretation of multielectrode array-derived, extracellular, electrical signals.
Collapse
Affiliation(s)
- Auriane C Ernault
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Rushd F M Al-Shama
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Jiuru Li
- Department of Medical Biology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Harsha D Devalla
- Department of Medical Biology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Joris R de Groot
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Ruben Coronel
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Edward Vigmond
- IHU Liryc, Fondation Bordeaux Université, Bordeaux, France
- University of Bordeaux, Talence, France
| | - Bastiaan J Boukens
- Department of Medical Biology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, Amsterdam, The Netherlands
- Department of Physiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
33
|
Roy S, Kang S, Choi KY, Lee KH, Shin KS, Kang JY. Implementation of an ultra-sensitive microwell-based electrochemical sensor for the detection of Alzheimer's disease. Biosens Bioelectron 2024; 247:115898. [PMID: 38104391 DOI: 10.1016/j.bios.2023.115898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/24/2023] [Accepted: 11/27/2023] [Indexed: 12/19/2023]
Abstract
Alzheimer's Disease (AD) is one of the most common neurodegenerative disorders in elderly people. It is diagnosed by detecting amyloid beta (Aβ) protein in cerebrospinal fluid (CSF) obtained by lumbar puncture or through expensive positron emission tomography (PET) imaging. Although blood-based diagnosis of AD offers a less invasive and cost-effective alternative, the quantification of Aβ is technically challenging due to its low abundance in peripheral blood. To address this, we developed a compact yet highly sensitive microwell-based electrochemical sensor with a densely packed microelectrode array (20 by 20) for enhancing sensitivity. Employing microwells on the working and counter electrodes minimized the leakage current from the metallic conductors into the assay medium, refining the signal fidelity. We achieved a detection limit <10 fg/mL for Aβ by elevating the signal-to-noise ratio, thus capable of AD biomarker quantification. Moreover, the microwell structure maintained the performance irrespective of variations in bead number, indicative of the sensor's robustness. The sensor's efficacy was validated through the analysis of Aβ concentrations in plasma samples from 96 subjects, revealing a significant distinction between AD patients and healthy controls with an area under the receiver operating characteristic curve (AUC) of 0.85. Consequently, our novel microwell-based electrochemical biosensor represents a highly sensitive platform for detecting scant blood-based biomarkers, including Aβ, offering substantial potential for advancing AD diagnostics.
Collapse
Affiliation(s)
- Soumi Roy
- Brain Science Institute, Biomedical Engineering, Korea Institute of Science and Technology, KIST School, Seoul, 02792, Republic of Korea; Department of Biomedical Engineering, University of Science and Technology, Daejeon, Republic of Korea
| | - Sarang Kang
- Gwangju Alzheimer's Disease and Related Dementia Cohort Research Center, Chosun University, Gwangju, 61452, Republic of Korea; BK21 FOUR Educational Research Group for Age-Associated Disorder Control Technology, Chosun University, Gwangju, 61452, Republic of Korea
| | - Kyu Yeong Choi
- Gwangju Alzheimer's Disease and Related Dementia Cohort Research Center, Chosun University, Gwangju, 61452, Republic of Korea; Kolab Inc., Gwangju, 61436, Republic of Korea
| | - Kun Ho Lee
- Gwangju Alzheimer's Disease and Related Dementia Cohort Research Center, Chosun University, Gwangju, 61452, Republic of Korea; Department of Biomedical Science, Chosun University, Gwangju, 61452, Republic of Korea; Korea Brain Research Institute, Daegu, 41062, Republic of Korea
| | | | - Ji Yoon Kang
- Brain Science Institute, Biomedical Engineering, Korea Institute of Science and Technology, KIST School, Seoul, 02792, Republic of Korea; Department of Biomedical Engineering, University of Science and Technology, Daejeon, Republic of Korea.
| |
Collapse
|
34
|
Dos Santos B, Vaz R, Braga AC, Rito M, Lucas D, Chamadoira C. Intracerebral hemorrhage after deep brain stimulation surgery guided with microelectrode recording: analysis of 297 procedures. Neurocirugia (Astur : Engl Ed) 2024; 35:79-86. [PMID: 37865159 DOI: 10.1016/j.neucie.2023.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 09/13/2023] [Indexed: 10/23/2023]
Abstract
OBJECTIVES Report the incidence of symptomatic and asymptomatic intracerebral hemorrhage (ICH) in patients submitted to deep brain stimulation (DBS) guided with microelectrode recording (MER) with further analysis of potential risk factors, both inherent to the patient and related to the pathology and surgical technique. METHODS We performed a retrospective observational study. 297 DBS procedures were concluded in 277 patients in a single hospital centre between January 2010 and December 2020. All surgeries were guided with MER. We analysed the incidence of symptomatic and asymptomatic ICH and its correlation to age, sex, diagnosis, hypertension and perioperative hypertension, diabetes, dyslipidaemia, antiplatelet drugs, anatomic target, and number of MER trajectories. RESULTS There were a total of 585 electrodes implanted in 277 patients. 16 ICH were observed, of which 6 were symptomatic and 10 asymptomatic, none of which incurred in permanent neurological deficit. The location of the hemorrhage varied between cortical and subcortical plans, always in relation with the trajectory or the final position of the electrode. The incidence of symptomatic ICH per lead-implantation was 1%, and the CT-scan demonstrated asymptomatic ICH in 1.7% more patients. Male patients or with hypertension are 2.7 and 2.2 times more likely to develop ICH, respectively. However, none of these characteristics has been shown to have a statistically significant association with the occurrence of ICH, as well as age, diagnosis, diabetes, dyslipidaemia, antiplatelet drugs, anatomic target, number of MER trajectories and perioperative hypertension. CONCLUSIONS MER-guided DBS is a safe technique, with low incidence of ICH and no permanent deficits in our study. Hypertension and male sex seem to be risk factors for the development of ICH in this surgery. Nevertheless, no statistically significant factors were found for the occurrence of this complication.
Collapse
Affiliation(s)
| | - Rui Vaz
- Faculty of Medicine of the University of Porto (FMUP), Porto, Portugal; Neurosurgery Department, Centro Hospitalar Universitário de São João (CHUSJ), Porto, Portugal
| | | | - Manuel Rito
- Neurosurgery Department, Centro Hospitalar Universitário de São João (CHUSJ), Porto, Portugal
| | - Diana Lucas
- Neurosurgery Department, Centro Hospitalar Universitário de São João (CHUSJ), Porto, Portugal
| | - Clara Chamadoira
- Faculty of Medicine of the University of Porto (FMUP), Porto, Portugal; Neurosurgery Department, Centro Hospitalar Universitário de São João (CHUSJ), Porto, Portugal
| |
Collapse
|
35
|
Tan H, Paulk AC, Stedelin B, Cleary DR, Nerison C, Tchoe Y, Brown EC, Bourhis A, Russman S, Lee J, Tonsfeldt KJ, Yang JC, Oh H, Ro YG, Lee K, Ganji M, Galton I, Siler D, Han SJ, Collins KL, Ben-Haim S, Halgren E, Cash SS, Dayeh S, Raslan AM. Intraoperative application and early experience with novel high-resolution, high-channel-count thin-film electrodes for human microelectrocorticography. J Neurosurg 2024; 140:665-676. [PMID: 37874692 DOI: 10.3171/2023.7.jns23885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 07/18/2023] [Indexed: 10/26/2023]
Abstract
OBJECTIVE The study objective was to evaluate intraoperative experience with newly developed high-spatial-resolution microelectrode grids composed of poly(3,4-ethylenedioxythiophene) with polystyrene sulfonate (PEDOT:PSS), and those composed of platinum nanorods (PtNRs). METHODS A cohort of patients who underwent craniotomy for pathological tissue resection and who had high-spatial-resolution microelectrode grids placed intraoperatively were evaluated. Patient demographic and baseline clinical variables as well as relevant microelectrode grid characteristic data were collected. The primary and secondary outcome measures of interest were successful microelectrode grid utilization with usable resting-state or task-related data, and grid-related adverse intraoperative events and/or grid dysfunction. RESULTS Included in the analysis were 89 cases of patients who underwent a craniotomy for resection of neoplasms (n = 58) or epileptogenic tissue (n = 31). These cases accounted for 94 grids: 58 PEDOT:PSS and 36 PtNR grids. Of these 94 grids, 86 were functional and used successfully to obtain cortical recordings from 82 patients. The mean cortical grid recording duration was 15.3 ± 1.15 minutes. Most recordings in patients were obtained during experimental tasks (n = 52, 58.4%), involving language and sensorimotor testing paradigms, or were obtained passively during resting state (n = 32, 36.0%). There were no intraoperative adverse events related to grid placement. However, there were instances of PtNR grid dysfunction (n = 8) related to damage incurred by suboptimal preoperative sterilization (n = 7) and improper handling (n = 1); intraoperative recordings were not performed. Vaporized peroxide sterilization was the most optimal sterilization method for PtNR grids, providing a significantly greater number of usable channels poststerilization than did steam-based sterilization techniques (median 905.0 [IQR 650.8-935.5] vs 356.0 [IQR 18.0-597.8], p = 0.0031). CONCLUSIONS High-spatial-resolution microelectrode grids can be readily incorporated into appropriately selected craniotomy cases for clinical and research purposes. Grids are reliable when preoperative handling and sterilization considerations are accounted for. Future investigations should compare the diagnostic utility of these high-resolution grids to commercially available counterparts and assess whether diagnostic discrepancies relate to clinical outcomes.
Collapse
Affiliation(s)
- Hao Tan
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
| | - Angelique C Paulk
- 2Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts
- 3Harvard Medical School, Boston, Massachusetts
| | - Brittany Stedelin
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
| | - Daniel R Cleary
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
- Departments of4Neurological Surgery
| | - Caleb Nerison
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
| | - Youngbin Tchoe
- 5Electrical and Computer Engineering, and
- 6Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea
- 10Ulsan National Institute of Science and Technology, Ulsan, Korea
| | - Erik C Brown
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
- 7Department of Neurological Surgery, Nicklaus Children's Hospital, Miami, Florida
| | | | | | - Jihwan Lee
- 5Electrical and Computer Engineering, and
| | - Karen J Tonsfeldt
- 5Electrical and Computer Engineering, and
- 8Department of Obstetrics, Gynecology, and Reproductive Sciences, Center for Reproductive Science and Medicine, University of California, San Diego, La Jolla, California
| | - Jimmy C Yang
- 2Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts
- 3Harvard Medical School, Boston, Massachusetts
| | - Hongseok Oh
- 5Electrical and Computer Engineering, and
- 9Soongsil University, Seoul, Korea
| | - Yun Goo Ro
- 5Electrical and Computer Engineering, and
- 9Soongsil University, Seoul, Korea
| | | | | | - Ian Galton
- 5Electrical and Computer Engineering, and
| | - Dominic Siler
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
| | - Seunggu Jude Han
- 12Department of Neurological Surgery, Stanford University, Palo Alto, California
| | - Kelly L Collins
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
- 11Papé Family Pediatric Research Institute, Oregon Health & Science University, Portland, Oregon; and
| | | | - Eric Halgren
- 13Neurology, University of California, San Diego, California
| | - Sydney S Cash
- 2Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts
- 3Harvard Medical School, Boston, Massachusetts
| | | | - Ahmed M Raslan
- 1Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
| |
Collapse
|
36
|
Furukawa R, Yoshikawa T, Murakami S, Tateno T. A piezoelectric micromachined ultrasound transducer combined with recording electrodes for acute brain preparations in vitro. J Neurosci Methods 2024; 403:110048. [PMID: 38151186 DOI: 10.1016/j.jneumeth.2023.110048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 12/11/2023] [Accepted: 12/21/2023] [Indexed: 12/29/2023]
Abstract
BACKGROUND Ultrasound stimulation is used to noninvasively stimulate the local and deep areas of the brain. However, the detailed cellular mechanisms of neural activation are still unclear because studies on micro-stimulation at the cellular level are lacking. NEW METHOD To modulate neural activity at the cellular level, we developed a piezoelectric micromachined ultrasound transducer (PMUT), having circular diaphragms for application on acute brain slice preparations. To monitor neural activities, additionally, we fabricated recording microelectrodes onto the same PMUT device for closed-loop application. RESULTS To examine the PMUT-driven cellular responses of a brain slice, intracellular calcium signals in individual cells were measured using two calcium indicators. We successfully observed the intracellular responses triggered by the ultrasound of our novel PMUT. In addition, we performed recordings of local field potentials in a brain slice, demonstrating its usefulness as a simultaneous recording interface. COMPARISON WITH EXISTING METHOD(S) Conventional ultrasound stimulators are open-loop systems that risk inducing excessive neural activity because of the absence of neural activity monitoring. In contrast, our PMUT is packaged in a single device with both stimulation and sensor interface for neuromodulation. Further, there are no published reports on in vitro microdevices that can be used for ultrasound stimulation in rodent cortical slices that are several hundred micrometers thick, which maintain the cortical laminar structure and intrinsic neural networks. CONCLUSIONS Our findings suggest that this novel PMUT device has the potential for being a powerful tool for in vitro brain slice applications and effective closed loop ultrasound stimulation.
Collapse
Affiliation(s)
- Ryo Furukawa
- Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Kita 14, Nishi 9, Kita-ku, Sapporo 060-0814, Japan.
| | - Takahiro Yoshikawa
- Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Kita 14, Nishi 9, Kita-ku, Sapporo 060-0814, Japan.
| | - Shuichi Murakami
- Osaka Research Institute of Industrial Science and Technology, 2-7-1, Ayumino, Izumi, Osaka 594-1157, Japan.
| | - Takashi Tateno
- Bioengineering and Bioinformatics, Faculty of Information Science and Technology, Hokkaido University, Kita 14, Nishi 9, Kita-ku, Sapporo 060-0814, Japan.
| |
Collapse
|
37
|
Tawakol O, Herman MD, Foxley S, Mushahwar VK, Towle VL, Troyk PR. In-vivo testing of a novel wireless intraspinal microstimulation interface for restoration of motor function following spinal cord injury. Artif Organs 2024; 48:263-273. [PMID: 37170929 DOI: 10.1111/aor.14562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/21/2023] [Accepted: 05/09/2023] [Indexed: 05/13/2023]
Abstract
BACKGROUND Spinal cord injury causes a drastic loss in motor and sensory function. Intraspinal microstimulation (ISMS) is an electrical stimulation method developed for restoring motor function by activating the spinal networks below the level of injury. Current ISMS technology uses fine penetrating microwires to stimulate the ventral horn of the lumbar enlargement. The penetrating wires traverse the dura mater through a transdural conduit that connects to an implantable pulse generator. OBJECTIVE A wireless, fully intradural ISMS implant was developed to mitigate the potential complications associated with the transdural conduit, including tethering and leakage of cerebrospinal fluid. METHODS Two wireless floating microelectrode array (WFMA) devices were implanted in the lumbar enlargement of an adult domestic pig. Voltage transients were used to assess the electrochemical stability of the interface. Manual flexion and extension movements of the spine were performed to evaluate the mechanical stability of the interface. Post-mortem 9T MRI imaging was used to confirm the location of the electrodes. RESULTS The WFMA-based ISMS interface successfully evoked extension and flexion movements of the hip joint. Stimulation thresholds remained stable following manual extension and flexion of the spine. CONCLUSION The preliminary results demonstrate the surgical feasibility as well as the functionality of the proposed wireless ISMS system.
Collapse
Affiliation(s)
- Omar Tawakol
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois, USA
| | - Martin D Herman
- Department of Neurosurgery, University of Chicago, Chicago, Illinois, USA
| | - Sean Foxley
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| | - Vivian K Mushahwar
- Department of Medicine and Neuroscience, Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada
- Sensory Motor Adaptive Rehabilitation Technology (SMART) Network, University of Alberta, Edmonton, Alberta, Canada
| | - Vernon L Towle
- Department of Neurology, University of Chicago, Chicago, Illinois, USA
| | - Philip R Troyk
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois, USA
- Sensory Motor Adaptive Rehabilitation Technology (SMART) Network, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
38
|
Verardo C, Mele LJ, Selmi L, Palestri P. Finite-element modeling of neuromodulation via controlled delivery of potassium ions using conductive polymer-coated microelectrodes. J Neural Eng 2024; 21:026002. [PMID: 38306702 DOI: 10.1088/1741-2552/ad2581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 02/02/2024] [Indexed: 02/04/2024]
Abstract
Objective. The controlled delivery of potassium is an interesting neuromodulation modality, being potassium ions involved in shaping neuron excitability, synaptic transmission, network synchronization, and playing a key role in pathological conditions like epilepsy and spreading depression. Despite many successful examples of pre-clinical devices able to influence the extracellular potassium concentration, computational frameworks capturing the corresponding impact on neuronal activity are still missing.Approach. We present a finite-element model describing a PEDOT:PSS-coated microelectrode (herein, simplyionic actuator) able to release potassium and thus modulate the activity of a cortical neuron in anin-vitro-like setting. The dynamics of ions in the ionic actuator, the neural membrane, and the cellular fluids are solved self-consistently.Main results. We showcase the capability of the model to describe on a physical basis the modulation of the intrinsic excitability of the cell and of the synaptic transmission following the electro-ionic stimulation produced by the actuator. We consider three case studies for the ionic actuator with different levels of selectivity to potassium: ideal selectivity, no selectivity, and selectivity achieved by embedding ionophores in the polymer.Significance. This work is the first step toward a comprehensive computational framework aimed to investigate novel neuromodulation devices targeting specific ionic species, as well as to optimize their design and performance, in terms of the induced modulation of neural activity.
Collapse
Affiliation(s)
- Claudio Verardo
- Polytechnic Department of Engineering and Architecture, Università degli Studi di Udine, Udine, Italy
- BioRobotics Institute and Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Leandro Julian Mele
- Polytechnic Department of Engineering and Architecture, Università degli Studi di Udine, Udine, Italy
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, United States of America
| | - Luca Selmi
- Department of Engineering "Enzo Ferrari", Università degli Studi di Modena e Reggio Emilia, Modena, Italy
| | - Pierpaolo Palestri
- Polytechnic Department of Engineering and Architecture, Università degli Studi di Udine, Udine, Italy
- Department of Engineering "Enzo Ferrari", Università degli Studi di Modena e Reggio Emilia, Modena, Italy
| |
Collapse
|
39
|
Ogata G, Yoneda M, Ogawa R, Hanawa A, Asai K, Yamagishi R, Honjo M, Aihara M, Einaga Y. Real-Time Measurement of Antiglaucoma Drugs in Porcine Eyes Using Boron-Doped Diamond Microelectrodes. ACS Sens 2024; 9:781-788. [PMID: 38244038 DOI: 10.1021/acssensors.3c02088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2024]
Abstract
The primary treatment for glaucoma, the most common cause of intermediate vision impairment, involves administering ocular hypotensive drugs in the form of topical eye drops. Observing real-time changes in the drugs that pass through the cornea and reach the anterior chamber of the eye is crucial for improving and developing safe, reliable, and effective medical treatments. Traditional methods for measuring temporal changes in drug concentrations in the aqueous humor employ separation analyzers such as LC-MS/MS. However, this technique requires multiple measurements on the eyes of various test subjects to track changes over time with a high temporal resolution. To address this issue, we have developed a measurement method that employs boron-doped diamond (BDD) microelectrodes to monitor real-time drug concentrations in the anterior chamber of the eye. First, we confirmed the electrochemical reactivity of 13 antiglaucoma drugs in a phosphate buffer solution with a pH of 7.4. Next, we optimized the method for continuous measurement of timolol maleate (TIM), a sympathetic beta-receptor antagonist, and generated calibration curves for each BDD microelectrode using aqueous humor collected from enucleated porcine eyes. We successfully demonstrated the continuous ex vivo monitoring of TIM concentrations in the anterior chambers of these enucleated porcine eyes. The results indicate that changes in intracameral TIM concentrations can be monitored through electrochemical measurements using BDD microelectrodes. This technique holds promise for future advancements in optimizing glaucoma treatment and drug administration strategies.
Collapse
Affiliation(s)
- Genki Ogata
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan
| | - Mao Yoneda
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan
| | - Risa Ogawa
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan
| | - Ai Hanawa
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan
| | - Kai Asai
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan
| | - Reiko Yamagishi
- Department of Ophthalmology, School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8655, Japan
| | - Megumi Honjo
- Department of Ophthalmology, School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8655, Japan
| | - Makoto Aihara
- Department of Ophthalmology, School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8655, Japan
| | - Yasuaki Einaga
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan
| |
Collapse
|
40
|
Shabani H, Zrenner E, Rathbun DL, Hosseinzadeh Z. Electrical Input Filters of Ganglion Cells in Wild Type and Degenerating rd10 Mouse Retina as a Template for Selective Electrical Stimulation. IEEE Trans Neural Syst Rehabil Eng 2024; 32:850-864. [PMID: 38294929 DOI: 10.1109/tnsre.2024.3360890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
Bionic vision systems are currently limited by indiscriminate activation of all retinal ganglion cells (RGCs)- despite the dozens of known RGC types which each encode a different visual message. Here, we use spike-triggered averaging to explore how electrical responsiveness varies across RGC types toward the goal of using this variation to create type-selective electrical stimuli. A battery of visual stimuli and a randomly distributed sequence of electrical pulses were delivered to healthy and degenerating (4-week-old rd10) mouse retinas. Ganglion cell spike trains were recorded during stimulation using a 60-channel microelectrode array. Hierarchical clustering divided the recorded RGC populations according to their visual and electrical response patterns. Novel electrical stimuli were presented to assess type-specific selectivity. In healthy retinas, responses fell into 35 visual patterns and 14 electrical patterns. In degenerating retinas, responses fell into 12 visual and 23 electrical patterns. Few correspondences between electrical and visual response patterns were found except for the known correspondence of ON visual type with upward deflecting electrical type and OFF cells with downward electrical profiles. Further refinement of the approach presented here may yet yield the elusive nuances necessary for type-selective stimulation. This study greatly deepens our understanding of electrical input filters in the context of detailed visual response characterization and includes the most complete examination yet of degenerating electrical input filters.
Collapse
|
41
|
Hettiarachchi P, Niyangoda S, Shigemoto A, Solowiej IJ, Burdette SC, Johnson MA. Caged Zn 2+ Photolysis in Zebrafish Whole Brains Reveals Subsecond Modulation of Dopamine Uptake. ACS Chem Neurosci 2024; 15:772-782. [PMID: 38301116 PMCID: PMC11036533 DOI: 10.1021/acschemneuro.3c00668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2024] Open
Abstract
Free, ionic zinc (Zn2+) modulates neurotransmitter dynamics in the brain. However, the sub-s effects of transient concentration changes of Zn2+ on neurotransmitter release and uptake are not well understood. To address this lack of knowledge, we have combined the photolysis of the novel caged Zn2+ compound [Zn(DPAdeCageOMe)]+ with fast scan cyclic voltammetry (FSCV) at carbon fiber microelectrodes in live, whole brain preparations from zebrafish (Danio rerio). After treating the brain with [Zn(DPAdeCageOMe)]+, Zn2+ was released by application of light that was gated through a computer-controlled shutter synchronized with the FSCV measurements and delivered through a 1 mm fiber optic cable. We systematically optimized the photocage concentration and light application parameters, including the total duration and light-to-electrical stimulation delay time. While sub-s Zn2+ application with this method inhibited DA reuptake, assessed by the first-order rate constant (k) and half-life (t1/2), it had no effect on the electrically stimulated DA overflow ([DA]STIM). Increasing the photocage concentration and light duration progressively inhibited uptake, with maximal effects occurring at 100 μM and 800 ms, respectively. Furthermore, uptake was inhibited 200 ms after Zn2+ photorelease, but no measurable effect occurred after 800 ms. We expect that application of this method to the zebrafish whole brain and other preparations will help expand the current knowledge of how Zn2+ affects neurotransmitter release/uptake in select neurological disease states.
Collapse
Affiliation(s)
- Piyanka Hettiarachchi
- Department of Chemistry and R.N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas 66045
| | - Sayuri Niyangoda
- Department of Chemistry and R.N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas 66045
| | - Austin Shigemoto
- Department of Chemistry and Biochemistry, Worcester Polytechnic Institute, Worcester, MA 01609
| | - Isabel J. Solowiej
- Department of Chemistry and R.N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas 66045
| | - Shawn C. Burdette
- Department of Chemistry and Biochemistry, Worcester Polytechnic Institute, Worcester, MA 01609
| | - Michael A. Johnson
- Department of Chemistry and R.N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas 66045
| |
Collapse
|
42
|
Sturgill B, Hernandez-Reynoso AG, Druschel LN, Smith TJ, Boucher PE, Hoeferlin GF, Thai TTD, Jiang MS, Hess JL, Alam NN, Menendez DM, Duncan JL, Cogan SF, Pancrazio JJ, Capadona JR. Reactive Amine Functionalized Microelectrode Arrays Provide Short-Term Benefit but Long-Term Detriment to In Vivo Recording Performance. ACS Appl Bio Mater 2024; 7:1052-1063. [PMID: 38290529 PMCID: PMC10880090 DOI: 10.1021/acsabm.3c01014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 02/01/2024]
Abstract
Intracortical microelectrode arrays (MEAs) are used for recording neural signals. However, indwelling devices result in chronic neuroinflammation, which leads to decreased recording performance through degradation of the device and surrounding tissue. Coating the MEAs with bioactive molecules is being explored to mitigate neuroinflammation. Such approaches often require an intermediate functionalization step such as (3-aminopropyl)triethoxysilane (APTES), which serves as a linker. However, the standalone effect of this intermediate step has not been previously characterized. Here, we investigated the effect of coating MEAs with APTES by comparing APTES-coated to uncoated controls in vivo and ex vivo. First, we measured water contact angles between silicon uncoated and APTES-coated substrates to verify the hydrophilic characteristics of the APTES coating. Next, we implanted MEAs in the motor cortex (M1) of Sprague-Dawley rats with uncoated or APTES-coated devices. We assessed changes in the electrochemical impedance and neural recording performance over a chronic implantation period of 16 weeks. Additionally, histology and bulk gene expression were analyzed to understand further the reactive tissue changes arising from the coating. Results showed that APTES increased the hydrophilicity of the devices and decreased electrochemical impedance at 1 kHz. APTES coatings proved detrimental to the recording performance, as shown by a constant decay up to 16 weeks postimplantation. Bulk gene analysis showed differential changes in gene expression between groups that were inconclusive with regard to the long-term effect on neuronal tissue. Together, these results suggest that APTES coatings are ultimately detrimental to chronic neural recordings. Furthermore, interpretations of studies using APTES as a functionalization step should consider the potential consequences if the final functionalization step is incomplete.
Collapse
Affiliation(s)
- Brandon
S. Sturgill
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Ana G. Hernandez-Reynoso
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Lindsey N. Druschel
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Thomas J. Smith
- School
of Behavioral and BrainSciences, The University
of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Pierce E. Boucher
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - George F. Hoeferlin
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Teresa Thuc Doan Thai
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Madison S. Jiang
- School
of Behavioral and BrainSciences, The University
of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Jordan L. Hess
- School
of Behavioral and BrainSciences, The University
of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Neeha N. Alam
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Dhariyat M. Menendez
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Jonathan L. Duncan
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Stuart F. Cogan
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Joseph J. Pancrazio
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Jeffrey R. Capadona
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| |
Collapse
|
43
|
Rodilla BL, Arché-Núñez A, Ruiz-Gómez S, Domínguez-Bajo A, Fernández-González C, Guillén-Colomer C, González-Mayorga A, Rodríguez-Díez N, Camarero J, Miranda R, López-Dolado E, Ocón P, Serrano MC, Pérez L, González MT. Flexible metallic core-shell nanostructured electrodes for neural interfacing. Sci Rep 2024; 14:3729. [PMID: 38355737 PMCID: PMC10866994 DOI: 10.1038/s41598-024-53719-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/04/2024] [Indexed: 02/16/2024] Open
Abstract
Electrodes with nanostructured surface have emerged as promising low-impedance neural interfaces that can avoid the charge-injection restrictions typically associated to microelectrodes. In this work, we propose a novel approximation, based on a two-step template assisted electrodeposition technique, to obtain flexible nanostructured electrodes coated with core-shell Ni-Au vertical nanowires. These nanowires benefit from biocompatibility of the Au shell exposed to the environment and the mechanical properties of Ni that allow for nanowires longer and more homogeneous in length than their only-Au counterparts. The nanostructured electrodes show impedance values, measured by electrochemical impedance spectroscopy (EIS), at least 9 times lower than those of flat reference electrodes. This ratio is in good accordance with the increased effective surface area determined both from SEM images and cyclic voltammetry measurements, evidencing that only Au is exposed to the medium. The observed EIS profile evolution of Ni-Au electrodes over 7 days were very close to those of Au electrodes and differently from Ni ones. Finally, the morphology, viability and neuronal differentiation of rat embryonic cortical cells cultured on Ni-Au NW electrodes were found to be similar to those on control (glass) substrates and Au NW electrodes, accompanied by a lower glial cell differentiation. This positive in-vitro neural cell behavior encourages further investigation to explore the tissue responses that the implantation of these nanostructured electrodes might elicit in healthy (damaged) neural tissues in vivo, with special emphasis on eventual tissue encapsulation.
Collapse
Affiliation(s)
- Beatriz L Rodilla
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias S/N, 28040, Madrid, Spain
| | - Ana Arché-Núñez
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
| | - Sandra Ruiz-Gómez
- Max Planck Institute for Chemical Physics of Solids, Dresden, Germany
| | - Ana Domínguez-Bajo
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
- Animal Molecular and Cellular Biology group (AMCB), Louvain Institute of Biomolecular Science and Technology (LIBST), Université catholique de Louvain, Place Croix du Sud 5, 1348 , Louvain la Neuve, Belgium
| | | | | | | | | | - Julio Camarero
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Department de Física de la Materia Condensada and Instituto "Nicolás Cabrera", Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Rodolfo Miranda
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Department de Física de la Materia Condensada and Instituto "Nicolás Cabrera", Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Elisa López-Dolado
- Hospital Nacional de Parapléjicos, SESCAM, Finca la Peraleda S/N, 45071, Toledo, Spain
- Design and development of Biomaterials for Neural Regeneration, HNP-SESCAM, Associated Unit With CSIC Through ICMM, Finca La Peraleda S/N, 45071, Toledo, Spain
| | - Pilar Ocón
- Departamento de Química Física Aplicada, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - María C Serrano
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
| | - Lucas Pérez
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias S/N, 28040, Madrid, Spain
| | | |
Collapse
|
44
|
Hornauer P, Prack G, Anastasi N, Ronchi S, Kim T, Donner C, Fiscella M, Borgwardt K, Taylor V, Jagasia R, Roqueiro D, Hierlemann A, Schröter M. DeePhys: A machine learning-assisted platform for electrophysiological phenotyping of human neuronal networks. Stem Cell Reports 2024; 19:285-298. [PMID: 38278155 PMCID: PMC10874850 DOI: 10.1016/j.stemcr.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 12/18/2023] [Accepted: 12/20/2023] [Indexed: 01/28/2024] Open
Abstract
Reproducible functional assays to study in vitro neuronal networks represent an important cornerstone in the quest to develop physiologically relevant cellular models of human diseases. Here, we introduce DeePhys, a MATLAB-based analysis tool for data-driven functional phenotyping of in vitro neuronal cultures recorded by high-density microelectrode arrays. DeePhys is a modular workflow that offers a range of techniques to extract features from spike-sorted data, allowing for the examination of functional phenotypes both at the individual cell and network levels, as well as across development. In addition, DeePhys incorporates the capability to integrate novel features and to use machine-learning-assisted approaches, which facilitates a comprehensive evaluation of pharmacological interventions. To illustrate its practical application, we apply DeePhys to human induced pluripotent stem cell-derived dopaminergic neurons obtained from both patients and healthy individuals and showcase how DeePhys enables phenotypic screenings.
Collapse
Affiliation(s)
- Philipp Hornauer
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland.
| | - Gustavo Prack
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland
| | - Nadia Anastasi
- Roche Pharma Research and Early Development, Neuroscience and Rare Diseases, Roche Innovation Center Basel, F. Hoffmann-La Roche, 4070 Basel, Switzerland
| | - Silvia Ronchi
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland
| | - Taehoon Kim
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland
| | | | - Michele Fiscella
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland; MaxWell Biosystems AG, 8047 Zürich, Switzerland
| | - Karsten Borgwardt
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland; Swiss Institute of Bioinformatics, 1015 Lausanne, Switzerland
| | - Verdon Taylor
- Department of Biomedicine, University of Basel, 4031 Basel, Switzerland
| | - Ravi Jagasia
- Roche Pharma Research and Early Development, Neuroscience and Rare Diseases, Roche Innovation Center Basel, F. Hoffmann-La Roche, 4070 Basel, Switzerland
| | - Damian Roqueiro
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland; Roche Pharma Research and Early Development, Neuroscience and Rare Diseases, Roche Innovation Center Basel, F. Hoffmann-La Roche, 4070 Basel, Switzerland
| | - Andreas Hierlemann
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland
| | - Manuel Schröter
- Department of Biosystems Science and Engineering, ETH Zürich, 4056 Basel, Switzerland
| |
Collapse
|
45
|
Sharafkhani N, Long JM, Adams SD, Kouzani AZ. A self-stiffening compliant intracortical microprobe. Biomed Microdevices 2024; 26:17. [PMID: 38345721 PMCID: PMC10861748 DOI: 10.1007/s10544-024-00700-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/06/2024] [Indexed: 02/15/2024]
Abstract
Utilising a flexible intracortical microprobe to record/stimulate neurons minimises the incompatibility between the implanted microprobe and the brain, reducing tissue damage due to the brain micromotion. Applying bio-dissolvable coating materials temporarily makes a flexible microprobe stiff to tolerate the penetration force during insertion. However, the inability to adjust the dissolving time after the microprobe contact with the cerebrospinal fluid may lead to inaccuracy in the microprobe positioning. Furthermore, since the dissolving process is irreversible, any subsequent positioning error cannot be corrected by re-stiffening the microprobe. The purpose of this study is to propose an intracortical microprobe that incorporates two compressible structures to make the microprobe both adaptive to the brain during operation and stiff during insertion. Applying a compressive force by an inserter compresses the two compressible structures completely, resulting in increasing the equivalent elastic modulus. Thus, instant switching between stiff and soft modes can be accomplished as many times as necessary to ensure high-accuracy positioning while causing minimal tissue damage. The equivalent elastic modulus of the microprobe during operation is ≈ 23 kPa, which is ≈ 42% less than the existing counterpart, resulting in ≈ 46% less maximum strain generated on the surrounding tissue under brain longitudinal motion. The self-stiffening microprobe and surrounding neural tissue are simulated during insertion and operation to confirm the efficiency of the design. Two-photon polymerisation technology is utilised to 3D print the proposed microprobe, which is experimentally validated and inserted into a lamb's brain without buckling.
Collapse
Affiliation(s)
- Naser Sharafkhani
- School of Engineering, Deakin University, Geelong, VIC, 3216, Australia
| | - John M Long
- School of Engineering, Deakin University, Geelong, VIC, 3216, Australia
| | - Scott D Adams
- School of Engineering, Deakin University, Geelong, VIC, 3216, Australia
| | - Abbas Z Kouzani
- School of Engineering, Deakin University, Geelong, VIC, 3216, Australia.
| |
Collapse
|
46
|
van der Moolen M, Lovera A, Ersoy F, Mommo S, Loskill P, Cesare P. Cancer-mediated axonal guidance of sensory neurons in a microelectrode-based innervation MPS. Biofabrication 2024; 16:025013. [PMID: 38262053 DOI: 10.1088/1758-5090/ad218a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 01/23/2024] [Indexed: 01/25/2024]
Abstract
Despite recent advances in the field of microphysiological systems (MPSs), availability of models capable of mimicking the interactions between the nervous system and innervated tissues is still limited. This represents a significant challenge in identifying the underlying processes of various pathological conditions, including neuropathic, cardiovascular and metabolic disorders. In this novel study, we introduce a compartmentalized three-dimensional (3D) coculture system that enables physiologically relevant tissue innervation while recording neuronal excitability. By integrating custom microelectrode arrays into tailored glass chips microfabricated via selective laser-etching, we developed an entirely novel class of innervation MPSs (INV-MPS). This INV-MPS allows for manipulation, visualization, and electrophysiological analysis of individual axons innervating complex 3D tissues. Here, we focused on sensory innervation of 3D tumor tissue as a model case study since cancer-induced pain represents a major unmet medical need. The system was compared with existing nociception models and successfully replicated axonal chemoattraction mediated by nerve growth factor (NGF). Remarkably, in the absence of NGF, 3D cancer spheroids cocultured in the adjacent compartment induced sensory neurons to consistently cross the separating barrier and establish fine innervation. Moreover, we observed that crossing sensory fibers could be chemically excited by distal application of known pain-inducing agonists only when cocultured with cancer cells. To our knowledge, this is the first system showcasing morphological and electrophysiological analysis of 3D-innervated tumor tissuein vitro, paving the way for a plethora of studies into innervation-related diseases and improving our understanding of underlying pathophysiology.
Collapse
Affiliation(s)
- Matthijs van der Moolen
- NMI Natural and Medical Sciences Institute at the University of Tübingen, Markwiesenstr. 55, 72770 Reutlingen, Germany
- Department for Microphysiological Systems, Institute of Biomedical Engineering, Eberhard Karls University Tübingen, Österbergstr. 3, 72074 Tübingen, Germany
| | - Andrea Lovera
- FEMTOprint SA, Via Industria 3, 6933 Muzzano, Switzerland
| | - Fulya Ersoy
- NMI Natural and Medical Sciences Institute at the University of Tübingen, Markwiesenstr. 55, 72770 Reutlingen, Germany
- Department for Microphysiological Systems, Institute of Biomedical Engineering, Eberhard Karls University Tübingen, Österbergstr. 3, 72074 Tübingen, Germany
| | - Sacha Mommo
- FEMTOprint SA, Via Industria 3, 6933 Muzzano, Switzerland
| | - Peter Loskill
- NMI Natural and Medical Sciences Institute at the University of Tübingen, Markwiesenstr. 55, 72770 Reutlingen, Germany
- Department for Microphysiological Systems, Institute of Biomedical Engineering, Eberhard Karls University Tübingen, Österbergstr. 3, 72074 Tübingen, Germany
| | - Paolo Cesare
- NMI Natural and Medical Sciences Institute at the University of Tübingen, Markwiesenstr. 55, 72770 Reutlingen, Germany
- Department for Microphysiological Systems, Institute of Biomedical Engineering, Eberhard Karls University Tübingen, Österbergstr. 3, 72074 Tübingen, Germany
- Current address: Eurac Research, Institute for Biomedicine, via Volta 13A, 39100 Bolzano, Italy
| |
Collapse
|
47
|
Jiang B, Zhang T, Liu S, Sheng Y, Hu J. Polydopamine-assisted aptamer-carrying tetrahedral DNA microelectrode sensor for ultrasensitive electrochemical detection of exosomes. J Nanobiotechnology 2024; 22:55. [PMID: 38331774 PMCID: PMC10854160 DOI: 10.1186/s12951-024-02318-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 01/26/2024] [Indexed: 02/10/2024] Open
Abstract
BACKGROUND Exosomes are nanoscale extracellular vesicles (30-160 nm) with endosome origin secreted by almost all types of cells, which are considered to be messengers of intercellular communication. Cancerous exosomes serve as a rich source of biomarkers for monitoring changes in cancer-related physiological status, because they carry a large number of biological macromolecules derived from parental tumors. The ultrasensitive quantification of trace amounts of cancerous exosomes is highly valuable for non-invasive early cancer diagnosis, yet it remains challenging. Herein, we developed an aptamer-carrying tetrahedral DNA (Apt-TDNA) microelectrode sensor, assisted by a polydopamine (PDA) coating with semiconducting properties, for the ultrasensitive electrochemical detection of cancer-derived exosomes. RESULTS The stable rigid structure and orientation of Apt-TDNA ensured efficient capture of suspended exosomes. Without PDA coating signal amplification strategy, the sensor has a linear working range of 102-107 particles mL-1, with LOD of ~ 69 exosomes and ~ 42 exosomes for EIS and DPV, respectively. With PDA coating, the electrochemical signal of the microelectrode is further amplified, achieving single particle level sensitivity (~ 14 exosomes by EIS and ~ 6 exosomes by DPV). CONCLUSIONS The proposed PDA-assisted Apt-TDNA microelectrode sensor, which integrates efficient exosome capture, sensitive electrochemical signal feedback with PDA coating signal amplification, provides a new avenue for the development of simple and sensitive electrochemical sensing techniques in non-invasive cancer diagnosis and monitoring treatment response.
Collapse
Affiliation(s)
- Bowen Jiang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Tenghua Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Silan Liu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Yan Sheng
- Institute of Translational Medicine, Shanghai University, Shanghai, 200444, China.
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| | - Jiaming Hu
- International Joint Laboratory of Catalytic Chemistry, State Key Laboratory of Advanced Special Steel, Innovation Institute of Carbon Neutrality, College of Sciences, Shanghai University, Shanghai, 200444, China.
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
48
|
Gao Y, Yin B, Liu X, Wu S. Difunctional Microelectrode Arrays for Single-Cell Electrical Stimulation and pH Detection. Anal Chem 2024; 96:2087-2093. [PMID: 38275169 DOI: 10.1021/acs.analchem.3c04766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Due to its direct effect on biomolecules and cells, electrical stimulation (ES) is now widely used to regulate cell proliferation, differentiation, and neurostimulation and is even used in the clinic for pain relief, treatment of nerve damage, and muscle rehabilitation. Conventional ES is mostly studied on cell populations, but the heterogeneity of cancer cells results in the inability to access the response of individual cells to ES. Therefore, detecting the extracellular pH change (ΔpHe) after ES at the single-cell level is important for the application of ES in tumor therapy. In this study, cellular ΔpHe after periodic impulse electrostimulation (IES) was monitored in situ by using a polyaniline (PANI)-modified gold microelectrode array. The PANI sensor had excellent sensitivity (53.68 mV/pH) and linear correlation coefficient (R2 = 0.999) over the pH range of 5.55-7.41. The cells showed different degrees of ΔpHe after the IES with different intervals and stimulation potential. A shorter pulse interval and a higher stimulation potential could effectively enhance stimulation and increase cellular ΔpHe. At 0.5 V potential stimulation, the cellular ΔpHe increased with decreasing pulse interval. However, if the pulse interval was long enough, even at a higher potential of 0.7 V, there was no significant additional ΔpHe due to the insufficient stimulus strength. Based on the above conclusions, the prepared PANI microelectrode arrays (MEAs) were capable of stimulating and detecting single cells, which contributed to the deeper application of ES in tumor therapy.
Collapse
Affiliation(s)
- Yuan Gao
- School of Chemistry, Dalian University of Technology, Dalian 116023, P. R. China
| | - Bing Yin
- School of Chemistry, Dalian University of Technology, Dalian 116023, P. R. China
| | - Xiaobo Liu
- School of Chemistry, Dalian University of Technology, Dalian 116023, P. R. China
| | - Shuo Wu
- School of Chemistry, Dalian University of Technology, Dalian 116023, P. R. China
| |
Collapse
|
49
|
Steinmetz PN. Simulation of background neuronal activity and noise in human intracranial microwire recordings. J Neurosci Methods 2024; 402:110017. [PMID: 38036184 DOI: 10.1016/j.jneumeth.2023.110017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/30/2023] [Accepted: 11/18/2023] [Indexed: 12/02/2023]
Abstract
BACKGROUND Human intracranial microwire recordings allow measurement of neuronal activity in human subjects at a fine temporal and spatial scale. The recorded extracellular potentials represent a mixture of action potentials from nearby neurons, local field potentials, and other noise sources. Signal processing of these recordings is used to separate the activity of putative single neurons from other background and noise. To better understand the separation of single neuron activity, one approach is to simulate the signals produced by neurons firing action potentials combined with background activity and noise. NEW METHOD This paper characterizes the background activity and noise in human intracranial microwire recordings and presents an accurate and efficient method of simulation using an infinite impulse response filter to color white noise. RESULTS AND COMPARISON This method reproduces the power spectral density of the background activity and noise over a frequency range of 1-5000 Hz and is over 200 times faster than previously used methods. It thus facilitates large scale studies of variation of noise sources, field potentials, and processing parameters. It performs equivalently in terms of spike sorting to simulation using white noise. Another advantage is that the simulated signals are known to arise from a pseudorandom number generator and cannot be the result of detecting simulated background spiking activity. CONCLUSIONS This approach provides a rapid and accurate method of simulating background noise and neural activity in human intracranial microwire recordings. It is suitable for use in large scale simulations to study spike sorting in this type of recording.
Collapse
|
50
|
Liu S, Wang Y, Zhao Y, Liu L, Sun S, Zhang S, Liu H, Liu S, Li Y, Yang F, Jiao M, Sun X, Zhang Y, Liu R, Mu X, Wang H, Zhang S, Yang J, Xie X, Duan X, Zhang J, Hong G, Zhang XD, Ming D. A Nanozyme-Based Electrode for High-Performance Neural Recording. Adv Mater 2024; 36:e2304297. [PMID: 37882151 DOI: 10.1002/adma.202304297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 10/19/2023] [Indexed: 10/27/2023]
Abstract
Implanted neural electrodes have been widely used to treat brain diseases that require high sensitivity and biocompatibility at the tissue-electrode interface. However, currently used clinical electrodes cannot meet both these requirements simultaneously, which hinders the effective recording of electronic signals. Herein, nanozyme-based neural electrodes incorporating bioinspired atomically precise clusters are developed as a general strategy with a heterogeneous design for multiscale and ultrasensitive neural recording via quantum transport and biocatalytic processes. Owing to the dual high-speed electronic and ionic currents at the electrode-tissue interface, the impedance of nanozyme electrodes is 26 times lower than that of state-of-the-art metal electrodes, and the acquisition sensitivity for the local field potential is ≈10 times higher than that of clinical PtIr electrodes, enabling a signal-to-noise ratio (SNR) of up to 14.7 dB for single-neuron recordings in rats. The electrodes provide more than 100-fold higher antioxidant and multi-enzyme-like activities, which effectively decrease 67% of the neuronal injury area by inhibiting glial proliferation and allowing sensitive and stable neural recording. Moreover, nanozyme electrodes can considerably improve the SNR of seizures in acute epileptic rats and are expected to achieve precise localization of seizure foci in clinical settings.
Collapse
Affiliation(s)
- Shuangjie Liu
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Yang Wang
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Yue Zhao
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Ling Liu
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Si Sun
- Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Science, Tianjin University, Tianjin, 300354, China
| | - Shaofang Zhang
- Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Science, Tianjin University, Tianjin, 300354, China
| | - Haile Liu
- Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Science, Tianjin University, Tianjin, 300354, China
| | - Shuhu Liu
- Beijing Synchrotron Radiation Facility (BSRF), Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS), Beijing, 100049, China
| | - Yonghui Li
- Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Science, Tianjin University, Tianjin, 300354, China
| | - Fan Yang
- Department of Materials Science and Engineering, Stanford University, Stanford, California, 94305, USA
| | - Menglu Jiao
- Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Science, Tianjin University, Tianjin, 300354, China
| | - Xinyu Sun
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Yuqin Zhang
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Renpeng Liu
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Xiaoyu Mu
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Hao Wang
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| | - Shu Zhang
- Tianjin Neurological Institute, Department of Neurosurgery, General Hospital, Tianjin Medical University, Tianjin, 300041, China
| | - Jiang Yang
- School of Electronics and Information Technology and Medicine, Sun Yat-sen University, Guangzhou, 510060, China
| | - Xi Xie
- School of Electronics and Information Technology and Medicine, Sun Yat-sen University, Guangzhou, 510060, China
| | - Xiaojie Duan
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, 100871, China
| | - Jianning Zhang
- Tianjin Neurological Institute, Department of Neurosurgery, General Hospital, Tianjin Medical University, Tianjin, 300041, China
| | - Guosong Hong
- Department of Materials Science and Engineering, Stanford University, Stanford, California, 94305, USA
| | - Xiao-Dong Zhang
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
- Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Science, Tianjin University, Tianjin, 300354, China
| | - Dong Ming
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China
| |
Collapse
|