1
|
Detection of Incidental Nonosseous Thoracic Pathology on State-of-the-Art Ultralow-Dose Protocol Computed Tomography in Pediatric Patients With Pectus Excavatum. J Comput Assist Tomogr 2022; 46:492-498. [DOI: 10.1097/rct.0000000000001285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
2
|
Facchini G, Ceccarelli L, Tomà P, Bartoloni A. Recent Imaging Advancements for Lung Metastases in Children with Sarcoma. Curr Med Imaging 2021; 17:236-243. [PMID: 33371858 DOI: 10.2174/1573405616666201228125657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 11/19/2020] [Accepted: 12/07/2020] [Indexed: 11/22/2022]
Abstract
In children and adolescents affected by musculoskeletal sarcomas (both soft tissue and bone sarcomas), the presence of lung metastases is a frequent complication, that should be known since the patient's prognosis, as management, and treatment depend on it. During the staging phase, the detection of lung metastases should be sensitive and specific, and it should be carried out by minimizing the radiation exposure. To deal with this problem, imaging has reached important goals in recent years, thanks to the development of cone-beam CT or low-dose computed tomography, with some new iterative reconstruction methods, such as Veo and ASIR. Imaging is also fundamental for the possibility to perform lung biopsies under CT guidance, with less morbidity, less time-consumption, and shorter recovery time, compared to surgical biopsies.Moreover, important results have also been demonstrated in the treatment of lung metastases, due to the improvement of new mini-invasive image-guided percutaneous thermal ablation procedures, which proved to be safe and effective also in young patients.
Collapse
Affiliation(s)
- Giancarlo Facchini
- Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Luca Ceccarelli
- Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Paolo Tomà
- Department of Imaging, IRCCS Ospedale Pediatrico Bambino Gesu, Rome, Italy
| | | |
Collapse
|
3
|
Combination of Deep Learning-Based Denoising and Iterative Reconstruction for Ultra-Low-Dose CT of the Chest: Image Quality and Lung-RADS Evaluation. AJR Am J Roentgenol 2020; 215:1321-1328. [PMID: 33052702 DOI: 10.2214/ajr.19.22680] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE. The objective of our study was to assess the effect of the combination of deep learning-based denoising (DLD) and iterative reconstruction (IR) on image quality and Lung Imaging Reporting and Data System (Lung-RADS) evaluation on chest ultra-low-dose CT (ULDCT). MATERIALS AND METHODS. Forty-one patients with 252 nodules were evaluated retrospectively. All patients underwent ULDCT (mean ± SD, 0.19 ± 0.01 mSv) and standard-dose CT (SDCT) (6.46 ± 2.28 mSv). ULDCT images were reconstructed using hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MBIR), and they were postprocessed using DLD (i.e., HIR-DLD and MBIR-DLD). SDCT images were reconstructed using filtered back projection. Three independent radiologists subjectively evaluated HIR, HIR-DLD, MBIR, and MBIR-DLD images on a 5-point scale in terms of noise, streak artifact, nodule edge, clarity of small vessels, homogeneity of the normal lung parenchyma, and overall image quality. Two radiologists independently evaluated the nodules according to Lung-RADS using HIR, MBIR, HIR-DLD, and MBIR-DLD ULDCT images and SDCT images. The median scores for subjective analysis were analyzed using Wilcoxon signed rank test with Bonferroni correction. Intraobserver agreement for Lung-RADS category between ULDCT and SDCT was evaluated using the weighted kappa coefficient. RESULTS. In the subjective analysis, ULDCT with DLD showed significantly better scores than did ULDCT without DLD (p < 0.001), and MBIR-DLD showed the best scores among the ULDCT images (p < 0.001) for all items. In the Lung-RADS evaluation, HIR showed fair or moderate agreement (reader 1 and reader 2: κw = 0.46 and 0.32, respectively); MBIR, moderate or good agreement (κw = 0.68 and 0.57); HIR-DLD, moderate agreement (κw = 0.53 and 0.48); and MBIR-DLD, good agreement (κw = 0.70 and 0.72). CONCLUSION. DLD improved the image quality of both HIR and MBIR on ULDCT. MBIR-DLD was superior to HIR_DLD for image quality and for Lung-RADS evaluation.
Collapse
|
4
|
Zhang G, Cao Y, Zhang J, Zhao Z, Zhang W, Zhou J. Epidermal growth factor receptor mutations in lung adenocarcinoma: associations between dual-energy spectral CT measurements and histologic results. J Cancer Res Clin Oncol 2020; 147:1169-1178. [PMID: 32980961 DOI: 10.1007/s00432-020-03402-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 09/19/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To analyze the relationship between dual-energy spectral CT and epidermal growth factor receptor (EGFR) mutation status in patients with lung adenocarcinoma. METHODS The quantitative parameters of spectral CT were analyzed in 208 patients with lung adenocarcinoma. The quantitative parameters including CT40keV and CT70keV values, effective atomic number (Zeff), iodine concentration (IC), water concentration (WC), and the slope of the spectral curve (λ HU) were calculated. Statistical analysis was used to determine the clinical characteristics and quantitative parameters for the diagnosis of EGFR-mutation status. The ROC curves were used to calculate diagnostic efficiency. RESULTS Sex (p = 0.027) and smoking history (p = 0.019) differed significantly according to the EGFR-mutation status. Spectral CT quantitative parameters (CT40keV and CT70keV values, λ HU, Zeff and IC) differed significantly between the EGFR mutant and the EGFR wild-type groups (p < 0.05) during the arterial phase (AP) and venous phase (VP). However, WC was not statistically different between the two groups (p > 0.05). ROC curve analysis revealed the combination of the significantly different quantitative parameters provided the best diagnostic performance for determining the EGFR-mutation status (AUC: 76.0%) in the AP, while the AUC during the VP was 75.6%. CONCLUSION The quantitative parameters of dual-energy spectral CT have potential value for identifying the EGFR-mutation status.
Collapse
Affiliation(s)
- Guojin Zhang
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Department of Radiology, Lanzhou University Second Hospital, Chengguan District, Cuiyingmen No.82, Lanzhou, 730030, People's Republic of China
| | - Yuntai Cao
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Department of Radiology, Lanzhou University Second Hospital, Chengguan District, Cuiyingmen No.82, Lanzhou, 730030, People's Republic of China
| | - Jing Zhang
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China
| | - Zhiyong Zhao
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China
| | - Wenjuan Zhang
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China
| | - Junlin Zhou
- Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China. .,Department of Radiology, Lanzhou University Second Hospital, Chengguan District, Cuiyingmen No.82, Lanzhou, 730030, People's Republic of China.
| |
Collapse
|
5
|
Warin Fresse K, Isorni MA, Dacher JN, Pontana F, Gorincour G, Boddaert N, Jacquier A, Raimondi F. Cardiac computed tomography angiography in the paediatric population: Expert consensus from the Filiale de cardiologie pédiatrique et congénitale (FCPC) and the Société française d'imagerie cardiaque et vasculaire diagnostique et interventionnelle (SFICV). Arch Cardiovasc Dis 2020; 113:579-586. [PMID: 32522436 DOI: 10.1016/j.acvd.2020.03.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 03/10/2020] [Accepted: 03/11/2020] [Indexed: 12/30/2022]
Abstract
This paper aims to provide a paediatric cardiac computed tomography angiography expert panel consensus based on the opinions of experts from the Société française d'imagerie cardiaque et vasculaire diagnostique et interventionnelle (SFICV) and the Filiale de cardiologie pédiatrique congénitale (FCPC). This expert panel consensus includes recommendations for indications, patient preparation, computed tomography angiography radiation dose reduction techniques and postprocessing techniques. We think that to realize its full potential and to avoid pitfalls, cardiac computed tomography angiography in children with congenital heart disease requires training and experience. Moreover, paediatric cardiac computed tomography angiography protocols should be standardized to acquire optimal images in this population with the lowest radiation dose possible, to prevent unnecessary radiation exposure. We also provide a suggested structured report and a list of acquisition protocols and technical parameters in relation to specific vendors.
Collapse
Affiliation(s)
- Karine Warin Fresse
- Imagerie cardiovasculaire fédération des cardiopathies congénitales, CHU de Nantes HGRL, 44093 Nantes, France
| | - Marc Antoine Isorni
- Unité de radiologie diagnostique et thérapeutique, hôpital Marie-Lannelongue, 92350 Le Plessis Robinson, France
| | - Jean Nicolas Dacher
- Cardiac MR/CT Unit, University Hospital, 76031 Rouen, France; Inserm U1096, UFR Médecine-Pharmacie, 76183 Rouen, France
| | - François Pontana
- Inserm UMR 1011, Department of Cardiovascular Radiology, EGID (European Genomic Institute for Diabetes), université de Lille, Institut Cœur-Poumon, Institut Pasteur de Lille, CHU de Lille, FR3508, 59000 Lille, France
| | - Guillaume Gorincour
- Image(2), institut méditerranéen d'imagerie médicale appliquée à la gynecologie, grossesse et enfance, 13008 Marseille, France
| | - Nathalie Boddaert
- Paediatric Radiology Unit, Hôpital Universitaire Necker-Enfants Malades, 75743 Paris, France
| | - Alexis Jacquier
- Department of Radiology, University of Marseille Méditerranée, CHU La Timone, Marseille, France
| | - Francesca Raimondi
- Unité médicochirurgicale de cardiologie congénitale et pédiatrique, centre de référence des maladies cardiaques congénitales complexes (M3C), hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743 Paris cedex 15, France.
| |
Collapse
|
6
|
Warin-Fresse K, Isornii MA, Dacher JN, Pontana F, Gorincour G, Boddaert N, Jacquier A, Raimondi F. Pediatric cardiac computed tomography angiography: Expert consensus from the Filiale de Cardiologie Pédiatrique et Congénitale (FCPC) and the Société Française d'Imagerie Cardiaque et Vasculaire diagnostique et interventionnelle (SFICV). Diagn Interv Imaging 2020; 101:335-345. [PMID: 32029386 DOI: 10.1016/j.diii.2020.01.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 01/11/2020] [Accepted: 01/15/2020] [Indexed: 02/06/2023]
Abstract
This article was designed to provide a pediatric cardiac computed tomography angiography (CCTA) expert panel consensus based on opinions of experts of the Société Française d'Imagerie Cardiaque et Vasculaire diagnostique et interventionnelle (SFICV) and of the Filiale de Cardiologie Pédiatrique Congénitale (FCPC). This expert panel consensus includes recommendations for indications, patient preparation, CTA radiation dose reduction techniques, and post-processing techniques. The consensus was based on data from available literature (original papers, reviews and guidelines) and on opinions of a group of specialists with extensive experience in the use of CT imaging in congenital heart disease. In order to reach high potential and avoid pitfalls, CCTA in children with congenital heart disease requires training and experience. Moreover, pediatric cardiac CCTA protocols should be standardized to acquire optimal images in this population with the lowest radiation dose possible to prevent unnecessary radiation exposure. We also provided a suggested structured report and a list of acquisition protocols and technical parameters in relation to specific vendors.
Collapse
Affiliation(s)
- K Warin-Fresse
- Department of Cardiovascular Imaging, CHU Nantes HGRL, 44093 Nantes, France
| | - M-A Isornii
- Department of Radiology, Hôpital Marie Lannelongue, 92350 Le Plessis-Robinson, France
| | - J-N Dacher
- Department of Radiology, Rouen University Hospital, 76031 Rouen, France; Inserm U1096, UFR Médecine-Pharmacie, University of Rouen, 76000 Rouen, France
| | - F Pontana
- Department of Cardiovascular Radiology, Institut Cœur-Poumon, CHU Lille, INSERM UMR 1011, Institut Pasteur de Lille, EGID, FR3508, Univ Lille, 59000 Lille, France
| | - G Gorincour
- Image2, Mediterranean Institute of Medical Imaging, 13008 Marseille, France
| | - N Boddaert
- Pediatric Radiology Unit, Hôpital Universitaire Necker Enfants-Malades, 75015 Paris, France; Université de Paris, Descartes-Paris 5, 75006 Paris, France
| | - A Jacquier
- Department of Radiology, University of Marseille Méditerranée, CHU la Timone, 13000 Marseille, France
| | - F Raimondi
- Unité Médicochirurgicale de Cardiologie Congénitale et Pédiatrique, Centre de Référence des Maladies Cardiaques Congénitales Complexes - M3C, Hôpital Universitaire Necker Enfants-Malades, 75015 Paris, France.
| |
Collapse
|
7
|
Tanoue S, Nakaura T, Iyama Y, Iyama A, Nagayama Y, Yoshida M, Yamashita Y. Diagnostic Performance of Dual-Layer Computed Tomography for Deep Vein Thrombosis in Indirect Computed Tomography Venography. Circ J 2020; 84:636-641. [PMID: 32101814 DOI: 10.1253/circj.cj-19-0722] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The aim of this study was to evaluate the quality and diagnostic performance of virtual monochromatic images (VMI) obtained with dual-layer dual-energy computed tomography (DL-DECT) during indirect CT venography (CTV) for deep vein thrombosis (DVT).Methods and Results:This retrospective study was approved by the Institutional Review Board, which waived the requirement for informed consent. We retrospectively enrolled 45 patients who underwent CTV with DL-DECT, and VMI were retrospectively generated. We compared the venous attenuation, noise, contrast, and contrast-to-noise ratio (CNR) between VMI with the highest CNR and conventional CT on paired t-test. Furthermore, we compared the pooled area under the curve (AUC) of each technique with Delong's test in 34 patients who underwent color Doppler ultrasonography. The 40-keV VMI had the best CNR. The noise was significantly lower on 40-keV (9.7±2.5 HU) than on 120-kVp VMI (10.5±2.5 HU; P<0.01). The contrast (120 kVp, 38.2±15.3 HU vs. 40 keV, 131.6±43.6 HU) and CNR (120 kVp, 3.8±1.7 vs. 40 keV, 14.4±6.1) were significantly higher in 40-keV VMI than in 120-kVp VMI (P<0.01). Furthermore, the pooled AUC was significantly higher for 40-keV (0.84) than for 120-kVp VMI (0.78; P=0.03). CONCLUSIONS In indirect CTV, 40-keV VMI obtained with DL-DECT offers better image quality and diagnostic performance for DVT than conventional CT.
Collapse
Affiliation(s)
- Shota Tanoue
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Yuji Iyama
- Department of Diagnostic Radiology, Red Cross Kumamoto Hospital
| | - Ayumi Iyama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Yasunori Nagayama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | | | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| |
Collapse
|
8
|
Hata A, Yanagawa M, Honda O, Miyata T, Tomiyama N. Ultra-low-dose chest computed tomography for interstitial lung disease using model-based iterative reconstruction with or without the lung setting. Medicine (Baltimore) 2019; 98:e15936. [PMID: 31145365 PMCID: PMC6708979 DOI: 10.1097/md.0000000000015936] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The aim of this study was to assess the effects of reconstruction on the image quality and quantitative analysis for interstitial lung disease (ILD) using filtered back projection (FBP) and model-based iterative reconstruction (MBIR) with the lung setting and the conventional setting on ultra-low-dose computed tomography (CT).Fifty-two patients with known ILD were prospectively enrolled and underwent CT at an ultra-low dose (0.18 ± 0.02 mSv) and a standard dose (7.01 ± 2.66 mSv). Ultra-low-dose CT was reconstructed using FBP (uFBP) and MBIR with the lung setting (uMBIR-Lung) and the conventional setting (uMBIR-Stnd). Standard-dose CT was reconstructed using FBP (sFBP). Three radiologists subjectively evaluated the images on a 3-point scale (1 = worst, 3 = best). For objective image quality analysis, regions of interest were placed in the lung parenchyma and the axillary fat, and standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. For 32 patients with clinically diagnosed idiopathic interstitial pneumonia, quantitative measurements including total lung volume (TLV) and the percentage of ILD volume (%ILDV) were obtained. The medians of 3 radiologists' scores were analyzed using the Wilcoxon signed-rank test and the objective noise was analyzed using the paired t test. The Bonferroni correction was used for multiple comparisons. The quantitative measurements were analyzed using the Bland-Altman method.uMBIR-Lung scored better than uMBIR-Stnd and worse than sFBP (P < .001), except for noise and streak artifact in subjective analysis. The SD decreased significantly in the order of uMBIR-Stnd, uMBIR-Lung, sFBP, and uFBP (P < .001). The SNR and CNR increased significantly in the order of uMBIR-Stnd, uMBIR-Lung, sFBP, and uFBP (P < .001). For TLV, there was no significant bias between ultra-low-dose MBIRs and sFBP (P > .3). For %ILDV, there was no significant bias between uMBIR-Lung and sFBP (p = 0.8), but uMBIR-Stnd showed significantly lower %ILDV than sFBP (P = .013).uMBIR-Lung provided more appropriate image quality than uMBIR-Stnd. Although inferior to standard-dose CT for image quality, uMBIR-Lung showed equivalent CT quantitative measurements to standard-dose CT.
Collapse
|
9
|
Hamamura T, Hayashida Y, Takeshita Y, Sugimoto K, Ueda I, Futatsuya K, Kakeda S, Aoki T, Korogi Y. The usefulness of full-iterative reconstruction algorithm for the visualization of cystic artery on CT angiography. Jpn J Radiol 2019; 37:526-533. [PMID: 31041661 DOI: 10.1007/s11604-019-00839-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 04/08/2019] [Indexed: 02/07/2023]
Abstract
PURPOSE To evaluate the potential of full-iterative reconstruction (IR) for improving image quality of the cystic artery on CT angiography and to assess observer performance. METHODS Thirty patients who underwent both liver dynamic CT and conventional angiography were included in this retrospective study. All CT data were reconstructed through filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR3D), and forward-projected, model-based, iterative reconstruction solution (FIRST), respectively. In objective study, we analyzed mean ΔCT numbers (the difference between the HU peak of the vessel and the background) and full-width at tenth-maximum (FWTM) of three parts of the cystic artery by profile curve method comparing the three reconstructions. Subjectively, visualization was evaluated using a four-point scale performed by two blinded observers. ANOVA was used for statistical analysis. RESULTS In all parts of the cystic artery, the mean ΔCT number of FIRST was shown to be significantly better than that of FBP and AIDR3D (p < 0.05). FWTM in FIRST was the smallest in all of the vessels. The mean visualization score was significantly better with FIRST than with other CT reconstructions (p < 0.05). CONCLUSIONS The FIRST algorithm led to improved CTA visualization of the cystic artery.
Collapse
Affiliation(s)
- Toshihiko Hamamura
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan.
| | - Yoshiko Hayashida
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Yohei Takeshita
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Koichiro Sugimoto
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Issei Ueda
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Koichiro Futatsuya
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Shingo Kakeda
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Takatoshi Aoki
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| | - Yukunori Korogi
- Department of Radiology, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, 807-8555, Japan
| |
Collapse
|
10
|
Afadzi M, Lysvik EK, Andersen HK, Martinsen ACT. Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality. Eur J Radiol 2019; 114:62-68. [PMID: 31005179 DOI: 10.1016/j.ejrad.2019.02.021] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 01/03/2019] [Accepted: 02/16/2019] [Indexed: 11/19/2022]
Abstract
PURPOSE To optimize image quality and radiation dose of chest CT with respect to various iterative reconstruction levels, detector collimations and body sizes. METHOD A Kyoto Kagaku Lungman with and without extensions was scanned using fixed ultra-low doses of 0.25, 0.49 and 0.74 mGy CTDIvol, and collimations of 40 and 80 mm. Images were reconstructed with the lung kernel, filtered back projection (FBP) and different ASIR-V levels (10-100%). Contrast-to-noise ratios (CNR) were calculated for 12 mm simulated lesions of different densities in the lung. Image noise, signal-to-noise ratios (SNR), variations in Hounsfield units (HU), noise power spectrum (NPS) and noise texture deviations (NTD) were evaluated for all reconstructions. NTD was calculated as percentage of pixels outside 3 standard deviations to evaluate IR-specific artefacts. RESULTS Compared to the FBP, image noise reduced (5-55%) with ASIR-V levels irrespective of dose or collimation. SNR correlated positively (r ≥ 0.925, p ≤ 0.001) with ASIR-V levels at all doses, collimations, and phantom sizes. ASIR-V enhanced the CNR of the lesion with the lowest contrast from 12.7-42.1 (0-100% ASIR-V) at 0.74 mGy with 40 mm collimation. As expected, higher SNR and CNR were measured in the smaller phantom than the bigger phantom. Uniform HU were observed between FBP and ASIR-V levels at all doses, collimations, and phantom sizes. NPS curves left-shifted towards lower frequencies at increasing levels of ASIR-V irrespective of collimation. A positive correlation (r ≥ 0.946, p ≥ 0.001) was observed between NTD and ASIR-V levels. NTD of the FBP was not significantly (p ≤ 0.087) different from NTD of ASIR-V ≤ 20%. The data from the NPS and NTD indicates a blotchier and coarser noise texture at higher levels of ASIR-V, especially at 100% ASIR-V. CONCLUSION In comparison with the FBP technique, ASIR-V enhanced quantitative image quality parameters at all ultra-low doses tested. Moreover, the use of ASIR-V showed consistency with body size and collimation. Hence, ASIR-V may be useful for improving image quality of chest CT at ultra-low doses.
Collapse
Affiliation(s)
- Mercy Afadzi
- Department of Diagnostic Physics, Oslo University Hospital, Oslo, Norway.
| | | | | | - Anne Catrine T Martinsen
- Department of Diagnostic Physics, Oslo University Hospital, Oslo, Norway; The Department of Physics, University of Oslo, Oslo, Norway
| |
Collapse
|
11
|
Choy S, Parhar D, Lian K, Schmiedeskamp H, Louis L, O'Connell T, McLaughlin P, Nicolaou S. Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*). Abdom Radiol (NY) 2019; 44:355-361. [PMID: 29980828 DOI: 10.1007/s00261-018-1687-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
PURPOSE To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). METHODS Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1-5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen's κ test. RESULTS With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). CONCLUSIONS Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.
Collapse
Affiliation(s)
- Stephen Choy
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada.
| | - Dennis Parhar
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada
| | - Kevin Lian
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada
| | | | - Luck Louis
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada
| | - Timothy O'Connell
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada
| | - Patrick McLaughlin
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada
| | - Savvas Nicolaou
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 3350-950 W 10th Avenue, Vancouver, BC, V5Z 1M9, Canada
| |
Collapse
|
12
|
Inoue T, Nakaura T, Yoshida M, Yokoyama K, Uetani H, Oda S, Utsunomiya D, Kitajima M, Harada K, Yamashita Y. Brain computed tomography using iterative reconstruction to diagnose acute middle cerebral artery stroke: usefulness in combination of narrow window setting and thin slice reconstruction. Neuroradiology 2018; 60:373-379. [PMID: 29476209 DOI: 10.1007/s00234-018-1982-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 01/11/2018] [Indexed: 12/16/2022]
Abstract
PURPOSE The purpose of this study is to determine whether iterative model reconstruction (IMR) optimized for brain CT could improve the detection of acute stroke in the setting of thin image slices and narrow window settings. METHODS We retrospectively reviewed 27 patients who presented acute middle cerebral artery (MCA) stroke. Images were reconstructed using filtered back projection (FBP; 1- and 5-mm slice thickness) and IMR (1 mm thickness), and contrast-to-noise ratios (CNRs) of infarcted and non-infarcted areas were compared. To analyze the performance of acute MCA stroke detection, we used receiver operating characteristic (ROC) curve techniques and compared 5-mm FBP with standard and narrow window settings, and 1-mm FBP and IMR with narrow window settings. RESULTS The CNR in 1-mm IMR (1.1 ± 1.0) was significantly higher than in 5- (0.8 ± 0.7) and 1-mm FBP (0.4 ± 0.4) (p < 0.001). Furthermore, the average area under the ROC curve was significantly higher with 1-mm IMR with narrow window settings (0.90, 95% CI: 0.86, 0.94) than it was with 5-mm FBP (0.78, 95% CI: 0.72, 0.83). CONCLUSION The combination of thin image slices and narrow window settings under IMR reconstruction provide better diagnostic performance for acute MCA stroke than conventional reconstruction methods.
Collapse
Affiliation(s)
- Taihei Inoue
- Department of Radiology, Amakusa Medical Center, 854-1 Jikiba, Amakusa, Kumamoto, Japan.
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Morikatsu Yoshida
- Department of Radiology, Amakusa Medical Center, 854-1 Jikiba, Amakusa, Kumamoto, Japan
| | - Koichi Yokoyama
- Department of Radiology, Amakusa Medical Center, 854-1 Jikiba, Amakusa, Kumamoto, Japan
| | - Hiroyuki Uetani
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Seitaro Oda
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Daisuke Utsunomiya
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Mika Kitajima
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Kazunori Harada
- Department of Surgery, Amakusa Medical Center, Kumamoto, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, Kumamoto, Japan
| |
Collapse
|
13
|
Qin L, Ma Z, Yan F, Yang W. Iterative model reconstruction (IMR) algorithm for reduced radiation dose renal artery CT angiography with different tube voltage protocols. Radiol Med 2017; 123:83-90. [DOI: 10.1007/s11547-017-0821-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Accepted: 09/28/2017] [Indexed: 10/18/2022]
|
14
|
Roik D, Barczuk M, Burzyńska Z, Biejat A, Żerańska M, Mierzewska-Schmidt M, Floriańczyk T, Brzewski M. Postnatal Evaluation of Congenital Chest Pathologies Using a Low-Dose Computed Tomography (CT) Protocol - a Pictorial Review. Pol J Radiol 2017; 82:466-472. [PMID: 29662574 PMCID: PMC5894012 DOI: 10.12659/pjr.900615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 11/25/2016] [Indexed: 11/24/2022] Open
Abstract
Computed tomography with its excellent spatial and temporal resolution remains a valuable diagnostic modality in pediatrics. On the other hand an increasing attention has been placed on the radiation risks associated with CT imaging, especially in children. In recent years, many advances in CT hardware and software, for example, automatic exposure control tools and iterative reconstruction techniques, have allowed for a reduction of applied radiation doses while maintaining image quality. The purpose of this paper is to present our protocol for chest CT imaging in the youngest age group, together with a pictorial review of congenital pathologies of the chest, and to emphasize factors that optimize postnatal CT imaging in infants. In our opinion, modern CT imaging with the use of dose reduction techniques and iterative reconstructions allows for a proper visualization of chest pathologies in small children, which has no influence on observer performance. The presented review of low-dose diagnostic images of a wide spectrum of congenital pathologies may serve as an example of routine utilization of the current concepts in pediatric CT optimization.
Collapse
Affiliation(s)
- Danuta Roik
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| | - Marzena Barczuk
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| | - Zofia Burzyńska
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| | - Agnieszka Biejat
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| | - Maria Żerańska
- Department of Pediatric Surgery, Medical University of Warsaw, Warsaw, Poland
| | | | - Tomasz Floriańczyk
- Department of Pediatric Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Michał Brzewski
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
15
|
Pediatric chest CT at chest radiograph doses: when is the ultralow-dose chest CT clinically appropriate? Emerg Radiol 2017; 24:369-376. [PMID: 28289906 DOI: 10.1007/s10140-017-1487-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Accepted: 02/07/2017] [Indexed: 10/20/2022]
Abstract
PURPOSE Computed tomography (CT) use in emergency departments represents a significant contribution to pediatric patients' exposure to ionizing radiation. Here, we evaluate whether ultralow-dose chest CT can be diagnostically adequate for other diagnoses and whether model-based iterative reconstruction (MBIR) can improve diagnostic adequacy compared to adaptive statistical iterative reconstruction (ASIR) at ultralow doses. METHODS Twenty children underwent chest CTs: 10 standard-dose reconstructed with ASIR and 10 ultralow-dose reconstructed with ASIR and MBIR. Four radiologists assessed images for their adequacy to exclude five hypothetical diagnoses: foreign body, fracture, lung metastasis, pulmonary infection, and interstitial lung disease. Additionally, pairwise comparison for subjective image quality was used to compare ultralow-dose chest CT with ASIR and MBIR. Radiation dose and objective image noise measures were obtained. RESULTS For exclusion of an airway foreign body, the adequacy of ultralow-dose CT was comparable to standard-dose (p = 0.6). For the remaining diagnoses, ultralow-dose CT was inferior to standard-dose (p = 0.03-<0.001). MBIR partially recovered the adequacy of ultralow-dose CT to exclude pulmonary infection (p = 0.017), but was suboptimal for the other diagnoses. Image noise was significantly lower with MBIR compared to ASIR in ultralow-dose CT (p < 0.001), although subjective preference showed only a slight advantage of MBIR (58 versus 42%). CONCLUSIONS Ultralow-dose chest CT may be adequate for airway assessment, but suboptimal for the evaluation parenchymal lung disease. Although MBIR improves objective and subjective image quality, it does not completely restore the diagnostic adequacy of ultralow-dose CT when compared to standard-dose CT.
Collapse
|
16
|
Inoue T, Nakaura T, Yoshida M, Yokoyama K, Hirata K, Kidoh M, Oda S, Utsunomiya D, Harada K, Yamashita Y. Diagnosis of small posterior fossa stroke on brain CT: effect of iterative reconstruction designed for brain CT on detection performance. Eur Radiol 2017; 27:3710-3715. [DOI: 10.1007/s00330-017-4773-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 01/30/2017] [Accepted: 02/09/2017] [Indexed: 10/20/2022]
|
17
|
Use of Model-based Iterative Reconstruction to Improve Detection of Congenital Cardiovascular Anomalies in Infants Undergoing Free-breathing Computed Tomographic Angiography. J Thorac Imaging 2017; 32:127-135. [PMID: 28221263 DOI: 10.1097/rti.0000000000000257] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
PURPOSE The aim of the study was to assess the detection of congenital cardiovascular anomalies (congenital heart disease) in neonates and infants using model-based iterative reconstruction (MBIR) algorithm compared with hybrid iterative reconstruction (HIR) and filtered back projection (FBP) reconstructions on axial computed tomography (CT) performed at minimum scanner dose. MATERIALS AND METHODS Over 1 year, all CT angiographies performed in infants below 3 months of age with congenital heart disease were assessed retrospectively. All were scanned on a 256-slice CT (Brilliance iCT) using single axial rotation at minimum allowable scanner dose (80 kV/10 mAs), with patients free-breathing. Intravenous contrast was 1 mL/kg. Scan reconstruction was 0.9 mm/0.45 mm overlap, reconstructed with FBP, HIR (iDose5), and MBIR (IMR2). The 3 reconstructions per study were anonymized and randomized. Four cardiac radiologists (23, 9, 7, and 6 y experience) evaluated each reconstruction on a workstation for presence of an atrial septal defect, a ventricular septal defect, patent ductus arteriosus, and surgical shunt or anomalies of the aorta, pulmonary arteries, and pulmonary veins. Unevaluable structures were classified as nondiagnostic. Gold standard was surgery or both echocardiogram and cardiac catheterization. The sensitivity, specificity, and accuracy were determined for each reconstruction. RESULTS Fifteen scans in 14 infants met the inclusion criteria, with a total of 48 anomalies. Pooled sensitivity for MBIR of 0.82 (range, 0.75 to 0.9) was significantly better than those for FBP (0.58; range, 0.54 to 0.6; P<0.001) and HIR (0.67; range, 0.60 to 0.79; P<0.001). Pooled accuracy of MBIR, HIR, and FBP was 0.91, 0.84, and 0.81, respectively. Readers deemed 39 and 15 structures nondiagnostic with FBP and HIR, respectively, versus 2 with MBIR (MBIR-FBP, MBIR-HIR, P<0.0001). The CTDIvol, DLP, and estimated dose for all cases was 0.52 mGy, 4.2 mGy×cm, and 0.16 mSv. CONCLUSIONS MBIR significantly improves the detection of congenital anomalies in neonates and infants undergoing CT angiography at minimum allowable dose.
Collapse
|
18
|
Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography. Pediatr Radiol 2017; 47:31-38. [PMID: 27637188 DOI: 10.1007/s00247-016-3698-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 07/09/2016] [Accepted: 08/26/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Hybrid iterative reconstruction can reduce image noise and produce better image quality compared with filtered back-projection (FBP), but few reports describe optimization of the iteration level. OBJECTIVE We optimized the iteration level of iDose4 and evaluated image quality for pediatric cardiac CT angiography. MATERIALS AND METHODS Children (n = 160) with congenital heart disease were enrolled and divided into full-dose (n = 84) and half-dose (n = 76) groups. Four series were reconstructed using FBP, and iDose4 levels 2, 4 and 6; we evaluated subjective quality of the series using a 5-grade scale and compared the series using a Kruskal-Wallis H test. For FBP and iDose4-optimal images, we compared contrast-to-noise ratios (CNR) and size-specific dose estimates (SSDE) using a Student's t-test. We also compared diagnostic-accuracy of each group using a Kruskal-Wallis H test. RESULTS Mean scores for iDose4 level 4 were the best in both dose groups (all P < 0.05). CNR was improved in both groups with iDose4 level 4 as compared with FBP. Mean decrease in SSDE was 53% in the half-dose group. Diagnostic accuracy for the four datasets were in the range 92.6-96.2% (no statistical difference). CONCLUSION iDose4 level 4 was optimal for both the full- and half-dose groups. Protocols with iDose4 level 4 allowed 53% reduction in SSDE without significantly affecting image quality and diagnostic accuracy.
Collapse
|
19
|
The Detection of Focal Liver Lesions Using Abdominal CT: A Comparison of Image Quality Between Adaptive Statistical Iterative Reconstruction V and Adaptive Statistical Iterative Reconstruction. Acad Radiol 2016; 23:1532-1538. [PMID: 27745816 DOI: 10.1016/j.acra.2016.08.013] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 08/05/2016] [Accepted: 08/07/2016] [Indexed: 01/21/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate image quality characteristics of abdominal computed tomography (CT) scans reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) vs currently using applied adaptive statistical iterative reconstruction (ASIR). MATERIALS AND METHOD This institutional review board-approved study included 35 consecutive patients who underwent CT of the abdomen. Among these 35 patients, 27 with focal liver lesions underwent abdomen CT with a 128-slice multidetector unit using the following parameters: fixed noise index of 30, 1.25 mm slice thickness, 120 kVp, and a gantry rotation time of 0.5 seconds. CT images were analyzed depending on the method of reconstruction: ASIR (30%, 50%, and 70%) vs ASIR-V (30%, 50%, and 70%). Three radiologists independently assessed randomized images in a blinded manner. Imaging sets were compared to focal lesion detection numbers, overall image quality, and objective noise with a paired sample t test. Interobserver agreement was assessed with the intraclass correlation coefficient. RESULTS The detection of small focal liver lesions (<10 mm) was significantly higher when ASIR-V was used when compared to ASIR (P <0.001). Subjective image noise, artifact, and objective image noise in liver were generally significantly better for ASIR-V compared to ASIR, especially in 50% ASIR-V. Image sharpness and diagnostic acceptability were significantly worse in 70% ASIR-V compared to various levels of ASIR. CONCLUSION Images analyzed using 50% ASIR-V were significantly better than three different series of ASIR or other ASIR-V conditions at providing diagnostically acceptable CT scans without compromising image quality and in the detection of focal liver lesions.
Collapse
|
20
|
Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction. Clin Imaging 2016; 40:1018-22. [DOI: 10.1016/j.clinimag.2016.06.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Revised: 05/03/2016] [Accepted: 06/13/2016] [Indexed: 11/23/2022]
|
21
|
Hultenmo M, Caisander H, Mack K, Thilander-Klang A. COMPARISON OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASIR™) AND MODEL-BASED ITERATIVE RECONSTRUCTION (VEO™) FOR PAEDIATRIC ABDOMINAL CT EXAMINATIONS: AN OBSERVER PERFORMANCE STUDY OF DIAGNOSTIC IMAGE QUALITY. RADIATION PROTECTION DOSIMETRY 2016; 169:107-114. [PMID: 26873711 DOI: 10.1093/rpd/ncv557] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The diagnostic image quality of 75 paediatric abdominal computed tomography (CT) examinations reconstructed with two different iterative reconstruction (IR) algorithms-adaptive statistical IR (ASiR™) and model-based IR (Veo™)-was compared. Axial and coronal images were reconstructed with 70 % ASiR with the Soft™ convolution kernel and with the Veo algorithm. The thickness of the reconstructed images was 2.5 or 5 mm depending on the scanning protocol used. Four radiologists graded the delineation of six abdominal structures and the diagnostic usefulness of the image quality. The Veo reconstruction significantly improved the visibility of most of the structures compared with ASiR in all subgroups of images. For coronal images, the Veo reconstruction resulted in significantly improved ratings of the diagnostic use of the image quality compared with the ASiR reconstruction. This was not seen for the axial images. The greatest improvement using Veo reconstruction was observed for the 2.5 mm coronal slices.
Collapse
Affiliation(s)
- Maria Hultenmo
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
| | - Håkan Caisander
- Department of Paediatric Radiology and Physiology, The Queen Silvia Children's Hospital, SE-413 45 Gothenburg, Sweden
| | - Karsten Mack
- Department of Paediatric Radiology and Physiology, The Queen Silvia Children's Hospital, SE-413 45 Gothenburg, Sweden
| | - Anne Thilander-Klang
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, SE-413 45 Gothenburg, Sweden
| |
Collapse
|
22
|
Xiao H, Liu Y, Tan H, Liang P, Wang B, Su L, Wang S, Gao J. A pilot study using low-dose Spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm to diagnose solitary pulmonary nodules. BMC Med Imaging 2015; 15:54. [PMID: 26576676 PMCID: PMC4647278 DOI: 10.1186/s12880-015-0096-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Accepted: 10/25/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Lung cancer is the most common cancer which has the highest mortality rate. With the development of computed tomography (CT) techniques, the case detection rates of solitary pulmonary nodules (SPN) has constantly increased and the diagnosis accuracy of SPN has remained a hot topic in clinical and imaging diagnosis. The aim of this study was to evaluate the combination of low-dose spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm in the diagnosis of solitary pulmonary nodules (SPN). METHODS 62 patients with SPN (42 cases of benign SPN and 20 cases of malignant SPN, pathology confirmed) were scanned by spectral CT with a dual-phase contrast-enhanced method. The iodine and water concentration (IC and WC) of the lesion and the artery in the image that had the same density were measured by the GSI (Gemstone Spectral Imaging) software. The normalized iodine and water concentration (NIC and NWC) of the lesion and the normalized iodine and water concentration difference (ICD and WCD) between the arterial and venous phases (AP and VP) were also calculated. The spectral HU (Hounsfield Unit ) curve was divided into 3 sections based on the energy (40-70, 70-100 and 100-140 keV) and the slopes (λHU) in both phases were calculated. The ICAP, ICVP, WCAP and WCVP, NIC and NWC, and the λHU in benign and malignant SPN were compared by independent sample t-test. RESULTS The iodine related parameters (ICAP, ICVP, NICAP, NICVP, and the ICD) of malignant SPN were significantly higher than that of benign SPN (t = 3.310, 1.330, 2.388, 1.669 and 3.251, respectively, P <0.05). The 3 λHU values of venous phase in malignant SPN were higher than that of benign SPN (t = 3.803, 2.846 and 3.205, P <0.05). The difference of water related parameters (WCAP, WCVP, NWCAP, NWCVP and WCD) between malignant and benign SPN were not significant (t = 0.666, 0.257, 0.104, 0.550 and 0.585, P > 0.05). CONCLUSIONS The iodine related parameters and the slope of spectral curve are useful markers to distinguish the benign from the malignant lung diseases, and its application is extremely feasible in clinical applications.
Collapse
Affiliation(s)
- Huijuan Xiao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| | - Yihe Liu
- The No.7 People's Hospital of Zhengzhou, 17 Jingnan 5th Road, Zhengzhou Economic and Technological Development Zone, Zhengzhou, Henan Province, 450000, China.
| | - Hongna Tan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| | - Pan Liang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| | - Bo Wang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| | - Lei Su
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| | - Suya Wang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| |
Collapse
|
23
|
Kwon H, Cho J, Oh J, Kim D, Cho J, Kim S, Lee S, Lee J. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique. Br J Radiol 2015; 88:20150463. [PMID: 26234823 DOI: 10.1259/bjr.20150463] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. METHODS 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. RESULTS At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. CONCLUSION Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. ADVANCES IN KNOWLEDGE This study represents the first clinical research experiment to use ASIR-V, the newest version of iterative reconstruction. Use of the ASIR-V algorithm decreased image noise and increased image quality when compared with the ASIR and FBP methods. These results suggest that high-quality low-dose CT may represent a new clinical option.
Collapse
Affiliation(s)
- Heejin Kwon
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Jinhan Cho
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Jongyeong Oh
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Dongwon Kim
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Junghyun Cho
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Sanghyun Kim
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Sangyun Lee
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| | - Jihyun Lee
- Department of Radiology, Dong-A University Hospital, Busan, Republic of Korea
| |
Collapse
|
24
|
Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v. J Comput Assist Tomogr 2015; 39:443-8. [PMID: 25654782 DOI: 10.1097/rct.0000000000000216] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The purpose of this study was to assess the image quality of a novel advanced iterative reconstruction (IR) method called as "adaptive statistical IR V" (ASIR-V) by comparing the image noise, contrast-to-noise ratio (CNR), and spatial resolution from those of filtered back projection (FBP) and adaptive statistical IR (ASIR) on computed tomography (CT) phantom image. MATERIALS AND METHODS We performed CT scans at 5 different tube currents (50, 70, 100, 150, and 200 mA) using 3 types of CT phantoms. Scanned images were subsequently reconstructed in 7 different scan settings, such as FBP, and 3 levels of ASIR and ASIR-V (30%, 50%, and 70%). The image noise was measured in the first study using body phantom. The CNR was measured in the second study using contrast phantom and the spatial resolutions were measured in the third study using a high-resolution phantom. We compared the image noise, CNR, and spatial resolution among the 7 reconstructed image scan settings to determine whether noise reduction, high CNR, and high spatial resolution could be achieved at ASIR-V. RESULTS At quantitative analysis of the first and second studies, it showed that the images reconstructed using ASIR-V had reduced image noise and improved CNR compared with those of FBP and ASIR (P < 0.001). At qualitative analysis of the third study, it also showed that the images reconstructed using ASIR-V had significantly improved spatial resolution than those of FBP and ASIR (P < 0.001). CONCLUSIONS Our phantom studies showed that ASIR-V provides a significant reduction in image noise and a significant improvement in CNR as well as spatial resolution. Therefore, this technique has the potential to reduce the radiation dose further without compromising image quality.
Collapse
|
25
|
Haggerty JE, Smith EA, Kunisaki SM, Dillman JR. CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose. Pediatr Radiol 2015; 45:989-97. [PMID: 25636530 DOI: 10.1007/s00247-015-3281-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 11/25/2014] [Accepted: 01/07/2015] [Indexed: 12/01/2022]
Abstract
BACKGROUND Different iterative reconstruction techniques are available for use in pediatric computed tomography (CT), but these techniques have not been systematically evaluated in infants. OBJECTIVE To determine the effect of iterative reconstruction on diagnostic performance, image quality and radiation dose in infants undergoing CT evaluation for congenital lung lesions. MATERIALS AND METHODS A retrospective review of contrast-enhanced chest CT in infants (<1 year) with congenital lung lesions was performed. CT examinations were reviewed to document the type of lung lesion, vascular anatomy, image noise measurements and image reconstruction method. CTDIvol was used to calculate size-specific dose estimates (SSDE). CT findings were correlated with intraoperative and histopathological findings. Analysis of variance and the Student's t-test were used to compare image noise measurements and radiation dose estimates between groups. RESULTS Fifteen CT examinations used filtered back projection (FBP; mean age: 84 days), 15 used adaptive statistical iterative reconstruction (ASiR; mean age: 93 days), and 11 used model-based iterative reconstruction (MBIR; mean age: 98 days). Compared to operative findings, 13/15 (87%), 14/15 (93%) and 11/11 (100%) lesions were correctly characterized using FBP, ASiR and MBIR, respectively. Arterial anatomy was correctly identified in 12/15 (80%) using FBP, 13/15 (87%) using ASiR and 11/11 (100%) using MBIR. Image noise was less for MBIR vs. ASiR (P < 0.0001). Mean SSDE was different among groups (P = 0.003; FBP = 7.35 mGy, ASiR = 1.89 mGy, MBIR = 1.49 mGy). CONCLUSION Congenital lung lesions can be adequately characterized in infants using iterative CT reconstruction techniques while maintaining image quality and lowering radiation dose.
Collapse
Affiliation(s)
- Jay E Haggerty
- Section of Pediatric Radiology, Department of Radiology, C.S. Mott Children's Hospital, University of Michigan Health System, 1540 E. Hospital Drive, SPC 4252, Ann Arbor, MI, 48109-4252, USA
| | | | | | | |
Collapse
|
26
|
Abstract
OBJECTIVE. Radiation exposure from CT examinations should be reduced to a minimum in children. Iterative reconstruction (IR) is a method to reduce image noise that can be used to improve CT image quality, thereby allowing radiation dose reduction. This article reviews the use of hybrid and model-based IRs in pediatric CT and discusses the possibilities, advantages, and disadvantages of IR in pediatric CT and the importance of radiation dose reduction for CT of children. CONCLUSION. IR is a promising and potentially highly valuable technique that can be used to substantially reduce the amount of radiation in pediatric imaging. Future research should determine the maximum achievable radiation dose reduction in pediatric CT that is possible without a loss of diagnostic image quality.
Collapse
|
27
|
Effect of iterative reconstruction algorithms on peripheral MDCT angiography virtual histology plaque volumes: have we been overestimating disease burden? Clin Imaging 2014; 38:821-5. [PMID: 25069752 DOI: 10.1016/j.clinimag.2014.06.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Revised: 06/07/2014] [Accepted: 06/19/2014] [Indexed: 11/22/2022]
Abstract
Our objective was to compare plaque volumes of multidetector computed tomographic images reconstructed using adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR), and filtered back projection (FBP). We reviewed 25 patients for a total of 50 extremities imaged on the same scanner. Calcified plaque FBP volume (3468.2 ± 2634.8 mm(3)) was higher than ASIR (2548.1 ± 2166.5 mm(3)). Calcified plaque FBP volume was higher than MBIR (mean=2345.7 ± 1935.4 mm(3)). Our findings suggest that traditional FBP methods overestimate disease compared to newer reconstruction methods.
Collapse
|