1
|
Metrard G, Cohen C, Bailly M. Comprehensive literature review of oral and intravenous contrast-enhanced PET/CT: a step forward? Front Med (Lausanne) 2024; 11:1373260. [PMID: 38566921 PMCID: PMC10985176 DOI: 10.3389/fmed.2024.1373260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 03/06/2024] [Indexed: 04/04/2024] Open
Abstract
The integration of diagnostic CT scans into PET/CT facilitates a comprehensive single examination, presenting potential advantages for patients seeking a thorough one-shot check-up. The introduction of iodinated contrast media during PET scanning raises theoretical concerns about potential interference with uptake quantification, due to the modification of tissue density on CT. Nevertheless, this impact appears generally insignificant for clinical use, compared to the intrinsic variability of standardized uptake values. On the other hand, with the growing indications of PET, especially 18F-FDG PET, contrast enhancement increases the diagnostic performances of the exam, and provides additional information. This improvement in performance achieved through contrast-enhanced PET/CT must be carefully evaluated considering the associated risks and side-effects stemming from the administration of iodinated contrast media. Within this article, we present a comprehensive literature review of contrast enhanced PET/CT, examining the potential impact of iodinated contrast media on quantification, additional side-effects and the pivotal clinically demonstrated benefits of an all-encompassing examination for patients. In conclusion, the clinical benefits of iodinated contrast media are mainly validated by the large diffusion in PET protocols. Contrary to positive oral contrast, which does not appear to offer any major advantage in patient management, intravenous iodine contrast media provides clinical benefits without significant artifact on images or quantification. However, studies on the benefit-risk balance for patients are still lacking.
Collapse
Affiliation(s)
- Gilles Metrard
- Nuclear Medicine Department, Orléans University Hospital, Orléans, France
- Centre de Biophysique Moléculaire, CNRS UPR 4301, Université d’Orléans, Orléans, France
| | - Clara Cohen
- Radiology Department, Orléans University Hospital, Orléans, France
| | - Matthieu Bailly
- Nuclear Medicine Department, Orléans University Hospital, Orléans, France
- Centre de Biophysique Moléculaire, CNRS UPR 4301, Université d’Orléans, Orléans, France
| |
Collapse
|
2
|
Alves VDPV, Ata NA, MacLean J, Sharp SE, Li Y, Brady S, Trout AT. Reduced count pediatric whole-body 18F-FDG PET imaging reconstruction with a Bayesian penalized likelihood algorithm. Pediatr Radiol 2024; 54:170-180. [PMID: 37962603 DOI: 10.1007/s00247-023-05801-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/24/2023] [Accepted: 10/26/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Advanced positron emission tomography (PET) image reconstruction methods promise to allow optimized PET/CT protocols with improved image quality, decreased administered activity and/or acquisition times. OBJECTIVE To evaluate the impact of reducing counts (simulating reduced acquisition time) in block sequential regularized expectation maximization (BSREM) reconstructed pediatric whole-body 18F-fluorodeoxyglucose (FDG) PET images, and to compare BSERM with ordered-subset expectation maximization (OSEM) reconstructed reduced-count images. MATERIALS AND METHODS Twenty children (16 male) underwent clinical whole-body 18F-FDG PET/CT examinations using a 25-cm axial field-of-view (FOV) digital PET/CT system at 90 s per bed (s/bed) with BSREM reconstruction (β=700). Reduced count simulations with varied BSREM β levels were generated from list-mode data: 60 s/bed, β=800; 50 s/bed, β=900; 40 s/bed, β=1000; and 30 s/bed, β=1300. In addition, a single OSEM reconstruction was created at 60 s/bed based on prior literature. Qualitative (Likert scores) and quantitative (standardized uptake value [SUV]) analyses were performed to evaluate image quality and quantitation across simulated reconstructions. RESULTS The mean patient age was 9.0 ± 5.5 (SD) years, mean weight was 38.5 ± 24.5 kg, and mean administered 18F-FDG activity was 4.5 ± 0.7 (SD) MBq/kg. Between BSREM reconstructions, no qualitative measure showed a significant difference versus the 90 s/bed β=700 standard (all P>0.05). SUVmax values for lesions were significantly lower from 90 s/bed, β=700 only at a simulated acquisition time of 30 s/bed, β=1300 (P=0.001). In a side-by-side comparison of BSREM versus OSEM reconstructions, 40 s/bed, β=1000 images were generally preferred over 60 s/bed TOF OSEM images. CONCLUSION In children who undergo whole-body 18F-FDG PET/CT on a 25-cm FOV digital PET/CT scanner, reductions in acquisition time or, by corollary, administered radiopharmaceutical activity of >50% from a clinical standard of 90 s/bed may be possible while maintaining diagnostic quality when a BSREM reconstruction algorithm is used.
Collapse
Affiliation(s)
- Vinicius de Padua V Alves
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
| | - Nadeen Abu Ata
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Joseph MacLean
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
| | - Susan E Sharp
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Yinan Li
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Samuel Brady
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA.
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| |
Collapse
|
3
|
Hu S, Lu R, Zhu Y, Zhu W, Jiang H, Bi S. Application of Medical Image Navigation Technology in Minimally Invasive Puncture Robot. SENSORS (BASEL, SWITZERLAND) 2023; 23:7196. [PMID: 37631733 PMCID: PMC10459274 DOI: 10.3390/s23167196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 08/11/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023]
Abstract
Microneedle puncture is a standard minimally invasive treatment and surgical method, which is widely used in extracting blood, tissues, and their secretions for pathological examination, needle-puncture-directed drug therapy, local anaesthesia, microwave ablation needle therapy, radiotherapy, and other procedures. The use of robots for microneedle puncture has become a worldwide research hotspot, and medical imaging navigation technology plays an essential role in preoperative robotic puncture path planning, intraoperative assisted puncture, and surgical efficacy detection. This paper introduces medical imaging technology and minimally invasive puncture robots, reviews the current status of research on the application of medical imaging navigation technology in minimally invasive puncture robots, and points out its future development trends and challenges.
Collapse
Affiliation(s)
| | - Rongjian Lu
- School of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China; (S.H.)
| | | | | | | | | |
Collapse
|
4
|
Bıçakçı N, Elli M. 18Fluorine-fluorodeoxyglucose PET/CT Imaging in Childhood Malignancies. Mol Imaging Radionucl Ther 2021; 30:18-27. [PMID: 33586403 PMCID: PMC7885281 DOI: 10.4274/mirt.galenos.2020.64436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Objectives: The aim of the study was to evaluate the utility of 18fluorine-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in the diagnosis, staging, restaging, and treatment response of childhood malignancies. Methods: This study included 52 patients (32 boys, 20 girls) who were referred to our clinic between November 2008 and December 2018 with the diagnosis of malignancy. The patients were evaluated retrospectively. Median age of the patients was 13 years (range 2-17). 18F-FDG was given to the patients intravenously, and time of flight with PET/16 slice CT was performed 1 hour thereafter. The lowest dose was 2 mCi (74 MBq) and the highest dose was 10 mCi (370 MBq). Fasting blood sugars of all patients were found below 200 mg/dL (11.1 mmol/L). Results: 18F-FDG PET/CT was performed to evaluate the response to treatment in 38 of 52 children, staging in 11 patients (staging and evaluation of the response to treatment in nine of them), restaging in 2 patients, restaging, and evaluation of the response to treatment in 1 patient. 18F-FDG PET/CT examination was reported as normal in 13 patients (5 girls, 8 boys). The pathological 18F-FDG uptake was detected in 39 patients (14 girls, 25 boys), which indicated metastasis and/or recurrence of the primary disease. Total number of deaths was 30 (13 girls, 17 boys). Conclusion: 18F-FDG PET/CT has a significant role for staging, restaging, treatment response, and detection of metastatic disease but it is limited for the early diagnosis of childhood cancers
Collapse
Affiliation(s)
- Nilüfer Bıçakçı
- University of Health Sciences Turkey, Samsun Training and Research Hospital, Clinic of Nuclear Medicine, Samsun, Turkey
| | - Murat Elli
- İstanbul Medipol University Faculty of Medicine, Department of Pediatric Oncology, İstanbul, Turkey
| |
Collapse
|