1
|
Bani A, Whitby C, Colbeck I, Dumbrell AJ, Ferguson RMW. Rapid In-Field Detection of Airborne Pathogens Using Loop-Mediated Isothermal Amplification (LAMP). Microorganisms 2024; 12:2578. [PMID: 39770780 PMCID: PMC11678261 DOI: 10.3390/microorganisms12122578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2024] [Revised: 12/04/2024] [Accepted: 12/06/2024] [Indexed: 01/11/2025] Open
Abstract
Multiple human and plant pathogens are dispersed and transmitted as bioaerosols (e.g., Mycobacterium tuberculosis, SARS-CoV-2, Legionella pneumophila, Aspergillus fumigatus, Phytophthora spp., and Fusarium graminearum). Rapid, on-site methods to detect airborne pathogens would greatly enhance our ability to monitor exposure and trigger early mitigation measures across different settings. Analysis of air samples for microorganisms in a regulatory context is often based on culture-based methods, which are slow, lack specificity, and are not suitable for detecting viruses. Molecular methods (based on nucleic acids) could overcome these challenges. For example, loop-mediated isothermal amplification (LAMP) is rapid, sensitive, specific, and may detect microbial pathogens from air samples in under 60 min. However, the low biomass in air samples makes recovering sufficient nucleic acids for detection challenging. To overcome this, we present a simple method for concentrating bioaerosols collected through liquid impingement (one of the most common methods for bioaerosol collection). This method paired with LAMP (or other molecular approaches) offers simple, rapid, and sensitive detection of pathogens. We validated this method using three airborne pathogens (Mycobacterium tuberculosis, Legionella pneumophila, and Aspergillus fumigatus), and we were able to detect fewer than five cells in a 15 mL liquid impinger air sample in under 60 min. This simple method offers rapid pathogen detection without the use of specialist equipment, and it can be used across healthcare, education, environmental monitoring, and military settings.
Collapse
Affiliation(s)
- Alessia Bani
- School of Life Sciences, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK; (A.B.); (C.W.); (I.C.); (A.J.D.)
- Aquatic Research Facility, Nature-Based Solutions Research Centre, University of Derby, Derby DE22 1GB, UK
| | - Corinne Whitby
- School of Life Sciences, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK; (A.B.); (C.W.); (I.C.); (A.J.D.)
| | - Ian Colbeck
- School of Life Sciences, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK; (A.B.); (C.W.); (I.C.); (A.J.D.)
| | - Alex J. Dumbrell
- School of Life Sciences, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK; (A.B.); (C.W.); (I.C.); (A.J.D.)
| | - Robert M. W. Ferguson
- School of Life Sciences, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK; (A.B.); (C.W.); (I.C.); (A.J.D.)
| |
Collapse
|
2
|
Screpis GA, Aleo A, Privitera N, Capuano GE, Farina R, Corso D, Libertino S, Coniglio MA. Biosensing Technologies for Detecting Legionella in Environmental Samples: A Systematic Review. Microorganisms 2024; 12:1855. [PMID: 39338529 PMCID: PMC11434302 DOI: 10.3390/microorganisms12091855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2024] [Revised: 08/31/2024] [Accepted: 09/05/2024] [Indexed: 09/30/2024] Open
Abstract
The detection of Legionella in environmental samples, such as water, is crucial for public health monitoring and outbreak prevention. Although effective, traditional detection methods, including culture-based techniques and polymerase chain reaction, have limitations such as long processing times, trained operators, and the need for specialized laboratory equipment. Biosensing technologies offer a promising alternative due to their rapid, sensitive, cost-effectiveness, and on-site detection capabilities. To summarize the current advancements in biosensor development for detecting Legionella in environmental samples, we used 'Legionella' AND 'biosensors' NEAR 'environmental samples' OR 'water' as keywords searching through the most relevant biomedical databases for research articles. After removing duplicates and inadequate articles from the n.1268 records identified using the PRISMA methodology exclusion criteria, we selected n.65 full-text articles which suited the inclusion criteria. Different results between the studies describing the current biosensing techniques, including optical, electrochemical, magnetic, and mass-sensitive sensors were observed. For each biosensing technique, sensitivity, specificity, and detection limits were evaluated. Furthermore, the integration of nanomaterials, microfluidics, and portable devices in biosensor systems' design were discussed, highlighting their role in enhancing detection performance. The potential challenges and future directions in the field of Legionella biosensing were also addressed, providing insights into the feasibility of implementing these technologies in routine environmental monitoring. Undoubtedly, biosensors can play a crucial role in the early detection and management of Legionella infections and outbreaks, ultimately protecting public health and safety.
Collapse
Affiliation(s)
- Giuseppe Andrea Screpis
- Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, Via S. Sofia 87, 95123 Catania, Italy; (G.A.S.); (A.A.); (N.P.); (M.A.C.)
| | - Andrea Aleo
- Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, Via S. Sofia 87, 95123 Catania, Italy; (G.A.S.); (A.A.); (N.P.); (M.A.C.)
| | - Natalia Privitera
- Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, Via S. Sofia 87, 95123 Catania, Italy; (G.A.S.); (A.A.); (N.P.); (M.A.C.)
| | - Giuseppe Emanuele Capuano
- Institute for Microelectronics and Microsystems (CNR—IMM), HQ, National Research Council of Italy, VIII Street Z.I., 5, 95121 Catania, Italy; (D.C.); (S.L.)
| | - Roberta Farina
- Institute for Microelectronics and Microsystems (CNR—IMM), HQ, National Research Council of Italy, VIII Street Z.I., 5, 95121 Catania, Italy; (D.C.); (S.L.)
- Department of Chemical Sciences, University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy
| | - Domenico Corso
- Institute for Microelectronics and Microsystems (CNR—IMM), HQ, National Research Council of Italy, VIII Street Z.I., 5, 95121 Catania, Italy; (D.C.); (S.L.)
| | - Sebania Libertino
- Institute for Microelectronics and Microsystems (CNR—IMM), HQ, National Research Council of Italy, VIII Street Z.I., 5, 95121 Catania, Italy; (D.C.); (S.L.)
| | - Maria Anna Coniglio
- Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, Via S. Sofia 87, 95123 Catania, Italy; (G.A.S.); (A.A.); (N.P.); (M.A.C.)
- Institute for Microelectronics and Microsystems (CNR—IMM), HQ, National Research Council of Italy, VIII Street Z.I., 5, 95121 Catania, Italy; (D.C.); (S.L.)
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Azienda Ospedaliero Universitaria Policlinico “G. Rodolico-San Marco”, Via S. Sofia 78, 95123 Catania, Italy
| |
Collapse
|
3
|
Singh S, Ahmed AI, Almansoori S, Alameri S, Adlan A, Odivilas G, Chattaway MA, Salem SB, Brudecki G, Elamin W. A narrative review of wastewater surveillance: pathogens of concern, applications, detection methods, and challenges. Front Public Health 2024; 12:1445961. [PMID: 39139672 PMCID: PMC11319304 DOI: 10.3389/fpubh.2024.1445961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Accepted: 07/18/2024] [Indexed: 08/15/2024] Open
Abstract
Introduction The emergence and resurgence of pathogens have led to significant global health challenges. Wastewater surveillance has historically been used to track water-borne or fecal-orally transmitted pathogens, providing a sensitive means of monitoring pathogens within a community. This technique offers a comprehensive, real-time, and cost-effective approach to disease surveillance, especially for diseases that are difficult to monitor through individual clinical screenings. Methods This narrative review examines the current state of knowledge on wastewater surveillance, emphasizing important findings and techniques used to detect potential pathogens from wastewater. It includes a review of literature on the detection methods, the pathogens of concern, and the challenges faced in the surveillance process. Results Wastewater surveillance has proven to be a powerful tool for early warning and timely intervention of infectious diseases. It can detect pathogens shed by asymptomatic and pre-symptomatic individuals, providing an accurate population-level view of disease transmission. The review highlights the applications of wastewater surveillance in tracking key pathogens of concern, such as gastrointestinal pathogens, respiratory pathogens, and viruses like SARS-CoV-2. Discussion The review discusses the benefits of wastewater surveillance in public health, particularly its role in enhancing existing systems for infectious disease surveillance. It also addresses the challenges faced, such as the need for improved detection methods and the management of antimicrobial resistance. The potential for wastewater surveillance to inform public health mitigation strategies and outbreak response protocols is emphasized. Conclusion Wastewater surveillance is a valuable tool in the fight against infectious diseases. It offers a unique perspective on the spread and evolution of pathogens, aiding in the prevention and control of disease epidemics. This review underscores the importance of continued research and development in this field to overcome current challenges and maximize the potential of wastewater surveillance in public health.
Collapse
Affiliation(s)
- Surabhi Singh
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Amina Ismail Ahmed
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Sumayya Almansoori
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Shaikha Alameri
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Ashraf Adlan
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Giovanni Odivilas
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Marie Anne Chattaway
- United Kingdom Health Security Agency, Gastrointestinal Bacteria Reference Laboratory, London, United Kingdom
| | - Samara Bin Salem
- Central Testing Laboratory, Abu Dhabi Quality and Conformity Council, Abu Dhabi, United Arab Emirates
| | - Grzegorz Brudecki
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| | - Wael Elamin
- Microbiology Lab, Reference and Surveillance Intelligence Department, Abu Dhabi, United Arab Emirates
| |
Collapse
|
4
|
Shaukat A, Chrouda A, Sadaf S, Alhamlan F, Eissa S, Zourob M. Cell-SELEX for aptamer discovery and its utilization in constructing electrochemical biosensor for rapid and highly sensitive detection of Legionella pneumophila serogroup 1. Sci Rep 2024; 14:14132. [PMID: 38898115 PMCID: PMC11187191 DOI: 10.1038/s41598-024-65075-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 06/17/2024] [Indexed: 06/21/2024] Open
Abstract
This study introduces an innovative electrochemical aptasensor designed for the highly sensitive and rapid detection of Legionella pneumophila serogroup 1 (L. pneumophila SG1), a particularly virulent strain associated with Legionellosis. Employing a rigorous selection process utilizing cell-based systematic evolution of ligands by exponential enrichment (cell-SELEX), we identified new high-affinity aptamers specifically tailored for L. pneumophila SG1. The selection process encompassed ten rounds of cell-SELEX cycles with live L. pneumophila, including multiple counter-selection steps against the closely related Legionella sub-species. The dissociation constant (Kd) of the highest affinity sequence to L. pneumophila SG1 was measured at 14.2 nM, representing a ten-fold increase in affinity in comparison with the previously reported aptamers. For the development of electrochemical aptasensor, a gold electrode was modified with the selected aptamer through the formation of self-assembled monolayers (SAMs). The newly developed aptasensor exhibited exceptional sensitivity, and specificity in detecting and differentiating various Legionella sp., with a detection limit of 5 colony forming units (CFU)/mL and an insignificant/negligible cross-reactivity with closely related sub-species. Furthermore, the aptasensor effectively detected L. pneumophila SG1 in spiked water samples, demonstrating an appreciable recovery percentage. This study shows the potential of our aptamer-based electrochemical biosensor as a promising approach for detecting L. pneumophila SG1 in diverse environments.
Collapse
Affiliation(s)
- Aysha Shaukat
- Department of Chemistry, Alfaisal University, 11533, Riyadh, Kingdom of Saudi Arabia
- School of Biochemistry and Biotechnology, University of the Punjab, Lahore, Pakistan
| | - Amani Chrouda
- Department of Chemistry, Alfaisal University, 11533, Riyadh, Kingdom of Saudi Arabia
| | - Saima Sadaf
- School of Biochemistry and Biotechnology, University of the Punjab, Lahore, Pakistan
| | - Fatimah Alhamlan
- King Faisal Specialist Hospital and Research Center, Riyadh, Kingdom of Saudi Arabia
| | - Shimaa Eissa
- Department of Chemistry, Khalifa University of Science and Technology, 127788, Abu Dhabi, United Arab Emirates
- Center for Catalysis and Separations, Khalifa University of Science and Technology, 127788, Abu Dhabi, United Arab Emirates
| | - Mohammed Zourob
- Department of Chemistry, Alfaisal University, 11533, Riyadh, Kingdom of Saudi Arabia.
| |
Collapse
|
5
|
Clinical and Laboratory Diagnosis of Legionella Pneumonia. Diagnostics (Basel) 2023; 13:diagnostics13020280. [PMID: 36673091 PMCID: PMC9858276 DOI: 10.3390/diagnostics13020280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/09/2023] [Accepted: 01/10/2023] [Indexed: 01/13/2023] Open
Abstract
Legionella pneumonia is a relatively rare but extremely progressive pulmonary infection with high mortality. Traditional cultural isolation remains the gold standard for the diagnosis of Legionella pneumonia. However, its harsh culture conditions, long turnaround time, and suboptimal sensitivity do not meet the clinical need for rapid and accurate diagnosis, especially for critically ill patients. So far, pathogenic detection techniques including serological assays, urinary antigen tests, and mass spectrometry, as well as nucleic acid amplification technique, have been developed, and each has its own advantages and limitations. This review summarizes the clinical characteristics and imaging findings of Legionella pneumonia, then discusses the advances, advantages, and limitations of the various pathogenetic detection techniques used for Legionella pneumonia diagnosis. The aim is to provide rapid and accurate guiding options for early identification and diagnosis of Legionella pneumonia in clinical practice, further easing healthcare burden.
Collapse
|
6
|
Du J, Ma B, Li J, Wang Y, Dou T, Xu S, Zhang M. Rapid Detection and Differentiation of Legionella pneumophila and Non-Legionella pneumophila Species by Using Recombinase Polymerase Amplification Combined With EuNPs-Based Lateral Flow Immunochromatography. Front Chem 2022; 9:815189. [PMID: 35198541 PMCID: PMC8859533 DOI: 10.3389/fchem.2021.815189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 12/28/2021] [Indexed: 11/13/2022] Open
Abstract
Legionella, a waterborne pathogen, is the main cause of Legionnaires’ disease. Therefore, timely and accurate detection and differentiation of Legionella pneumophila and non-Legionella pneumophila species is crucial. In this study, we develop an easy and rapid recombinase polymerase amplification assay combined with EuNPs-based lateral flow immunochromatography (EuNPs-LFIC-RPA) to specifically distinguish Legionella pneumophila and non-Legionella pneumophila. We designed primers based on the mip gene of Legionella pneumophila and the 5S rRNA gene of non-Legionella pneumophila. The recombinase polymerase amplification reaction could go to completion in 10 min at 37°C, and the amplification products could be detected within 5 min with EuNPs-LFIC strips. Using a florescent test strip reader, the quantitative results were achieved by reading the colored signal intensities on the strips. The sensitivity was 1.6 × 101 CFU/ml, and a linear standard linear curve plotted from the test strip reader had a correlation coefficient for the determination of Legionella pneumophila (R2 = 0.9516). Completed concordance for the presence or absence of Legionella pneumophila by EuNPs-LFIC-RPA and qPCR was 97.32% (κ = 0.79, 95% CI), according to an analysis of practical water samples (n = 112). In short, this work shows the feasibility of EuNPs-LFIC-RPA for efficient and rapid monitoring of Legionella pneumophila and non-Legionella pneumophila in water samples.
Collapse
|
7
|
Buultjens AH, Vandelannoote K, Sharkey LK, Howden BP, Monk IR, Lee JYH, Stinear TP. Low-Cost, Open-Source Device for High-Performance Fluorescence Detection of Isothermal Nucleic Acid Amplification Reactions. ACS Biomater Sci Eng 2021; 7:4982-4990. [PMID: 34521204 DOI: 10.1021/acsbiomaterials.1c01105] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The ability to detect SARS-CoV-2 is critical to implementing evidence-based strategies to address the COVID-19 global pandemic. Expanding SARS-CoV-2 diagnostic ability beyond well-equipped laboratories widens the opportunity for surveillance and control efforts. However, such advances are predicated on the availability of rapid, scalable, accessible, yet high-performance diagnostic platforms. Methods to detect viral RNA using reverse transcription loop-mediated isothermal amplification (RT-LAMP) show promise as rapid and field-deployable tests; however, the per-unit costs of the required diagnostic hardware can be a barrier for scaled deployment. Here, we describe a diagnostic hardware configuration for LAMP technology, named the FABL-8, that can be built for approximately US$380 per machine and provide results in under 30 min. Benchmarking showed that FABL-8 has a similar performance to a high-end commercial instrument for detecting fluorescence-based LAMP reactions. Performance testing of the instrument with RNA extracted from a SARS-CoV-2 virus dilution series revealed an analytical detection sensitivity of 50 virus copies per microliter-a detection threshold suitable to detect patient viral load in the first few days following symptom onset. In addition to the detection of SARS-CoV-2, we show that the system can be used to detect the presence of two bacterial pathogens, demonstrating the versatility of the platform for the detection of other pathogens. This cost-effective and scalable hardware alternative allows democratization of the instrumentation required for high-performance molecular diagnostics, such that it could be available to laboratories anywhere-supporting infectious diseases surveillance and research activities in resource-limited settings.
Collapse
Affiliation(s)
- Andrew H Buultjens
- Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia
| | - Koen Vandelannoote
- Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia
| | - Liam K Sharkey
- Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia
| | - Benjamin P Howden
- Microbiological Diagnostic Unit Public Health Laboratory, Level 1, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia.,Doherty Applied Microbial Genomics, Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia.,Department of Infectious Diseases, Austin Hospital, 145 Studley Road, Heidelberg 3084, Victoria, Australia
| | - Ian R Monk
- Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia
| | - Jean Y H Lee
- Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia.,Department of Infectious Diseases, Monash Health, 246 Clayton Road, Clayton 3168, Victoria, Australia
| | - Timothy P Stinear
- Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia.,Doherty Applied Microbial Genomics, Department of Microbiology and Immunology, The University of Melbourne at The Doherty Institute for Infection and Immunity, 792 Elizabeth Street, Melbourne 3000, Victoria, Australia
| |
Collapse
|
8
|
Vittal R, Raj JRM, Kumar BK, Karunasagar I. Advances in Environmental Detection and Clinical Diagnostic Tests for Legionella Species. JOURNAL OF HEALTH AND ALLIED SCIENCES NU 2021. [DOI: 10.1055/s-0041-1731863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Abstract
Legionella is a fastidious organism that is difficult to culture in the lab but is widely distributed in environmental, domestic, and hospital settings. The clinical manifestations due to Legionella infections range from mild fever to fatal pneumonia and multiorgan pathologies. Legionella outbreaks though prevalent globally are not reported in developing countries due to difficulties in isolating this organism and the lack of simple diagnostic protocols. Here, we review the literature from across countries to present various methods used to detect Legionella from environmental and clinical samples. We compare the sensitivity and the specificity of the conventional culture-based assays with the recent methods and discuss approaches to develop better detection and diagnostic tests. With better cost-effective detection techniques and regular monitoring of the susceptible sites, which may harbor Legionella colonies, most of the Legionella infections can be prevented. As a result, considerable burden, caused by Legionella infections, on the healthcare system, in especially economically weaker countries, can be mitigated.
Collapse
Affiliation(s)
- Rajeshwari Vittal
- Division of Infectious Diseases, Nitte University Centre for Science Education and Research, Deralakatte, Mangaluru, Karnataka, India
| | - Juliet Roshini Mohan Raj
- Division of Infectious Diseases, Nitte University Centre for Science Education and Research, Deralakatte, Mangaluru, Karnataka, India
| | - Ballamoole Krishna Kumar
- Division of Infectious Diseases, Nitte University Centre for Science Education and Research, Deralakatte, Mangaluru, Karnataka, India
| | - Indrani Karunasagar
- Nitte University Centre for Science Education and Research, Mangaluru, Karnataka, India
| |
Collapse
|
9
|
Oda N, Taki T, Mitani R, Takata I. Legionella longbeachae pneumonia: A case report and literature review in Japan. J Infect Chemother 2021; 27:751-754. [PMID: 33402302 DOI: 10.1016/j.jiac.2020.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 12/07/2020] [Accepted: 12/12/2020] [Indexed: 10/22/2022]
Abstract
Herein, we report the case of a 74-year-old man diagnosed with Legionella pneumonia detected by Loop-Mediated Isothermal Amplification (LAMP) method, which was suspected to have been transmitted from the potting soil. Legionella longbeachae was identified in the sputum culture. The patient was intubated and maintained on mechanical ventilation. Antimicrobial therapy with azithromycin was also administered. His symptoms were resolved and he was discharged after 26 days of hospitalization. Legionella longbeachae pneumonia rarely occurs in Japan, and published literature of Legionella longbeachae pneumonia cases in Japan was reviewed. Patients with severe pneumonia exposed to potting soils, but with negative urinary antigen test results, should be examined by LAMP method.
Collapse
Affiliation(s)
- Naohiro Oda
- Department of Internal Medicine, Fukuyama City Hospital, Fukuyama, Japan.
| | - Takahiro Taki
- Department of Internal Medicine, Fukuyama City Hospital, Fukuyama, Japan
| | - Reo Mitani
- Department of Internal Medicine, Fukuyama City Hospital, Fukuyama, Japan
| | - Ichiro Takata
- Department of Internal Medicine, Fukuyama City Hospital, Fukuyama, Japan
| |
Collapse
|
10
|
Nakanishi M, Shiroshita A, Nakashima K, Takeshita M, Kiguchi T, Yamada H. Clinical and computed tomographic features of Legionella pneumonia with negative urine antigen test results. Respir Investig 2020; 59:204-211. [PMID: 33339738 DOI: 10.1016/j.resinv.2020.11.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 11/11/2020] [Accepted: 11/16/2020] [Indexed: 01/10/2023]
Abstract
BACKGROUND Legionella spp. can cause severe pneumonia and most Legionella pneumonia (LP) cases are diagnosed using the urine antigen test (UAT). However, diagnosis of LP with negative UAT results (LPNUAT) is challenging. We investigated the clinical and radiological features of LPNUAT. METHODS We retrospectively collected LP cases with positive UAT (LPPUAT) and cases of suspected LP with negative UAT that were examined by Legionella culture between July 2014 and March 2020. We investigated the clinical and CT findings for LP that showed negative UAT results and was diagnosed by culture and compared these findings with those for other pneumonias suspicious for LP with negative results in UAT and Legionella culture (OPSLP). RESULTS Eight LPNUAT, 20 LPPUAT, and 19 OPSLP cases were included in this study. There were no significant differences in the clinical and CT findings between LPPUAT and LPNUAT when examined by UAT. In LPNUAT, dyspnea, renal dysfunction, liver dysfunction, and bilateral lesions were more commonly observed and inflammatory changes and the number of affected lobes were significantly higher when examined by culture than when examined by UAT. Comparison to OPSLP, LPNUAT did not show such differences, but rather showed disturbances in consciousness, hyponatremia and rhabdomyolysis. Furthermore, lobar consolidation was observed more frequently and bronchial wall thickening and centrilobular nodules were observed less frequently in LPNUAT. CONCLUSIONS LP characteristics such as disturbance of consciousness, hyponatremia, rhabdomyolysis, lobar consolidation, and less bronchial wall thickening and centrilobular nodule contribute to the diagnosis of LP in patients with negative UAT results.
Collapse
Affiliation(s)
- Masanori Nakanishi
- Department of Respiratory Medicine, Ichinomiya-nishi Hospital, Ichinomiya, Japan.
| | - Akihiro Shiroshita
- Department of Respiratory Medicine, Ichinomiya-nishi Hospital, Ichinomiya, Japan
| | - Kiyoshi Nakashima
- Department of Respiratory Medicine, Ichinomiya-nishi Hospital, Ichinomiya, Japan
| | - Masafumi Takeshita
- Department of Respiratory Medicine, Ichinomiya-nishi Hospital, Ichinomiya, Japan
| | - Takao Kiguchi
- Department of Radiology, Ichinomiya-nishi Hospital, Ichinomiya, Japan
| | - Hiroki Yamada
- Department of Radiology, Ichinomiya-nishi Hospital, Ichinomiya, Japan
| |
Collapse
|
11
|
Kawashima A, Katagiri D, Kondo I, Sakamoto E, Suzuki M, Arai Y, Sato F, Tada M, Hinoshita F. Fatal Fulminant Legionnaires' Disease in a Patient on Maintenance Hemodialysis. Intern Med 2020; 59:1913-1918. [PMID: 32321897 PMCID: PMC7474993 DOI: 10.2169/internalmedicine.4530-20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
We herein report a case of fulminant Legionnaires' disease with autopsy findings in a patient on maintenance hemodialysis (HD). Chronic kidney disease is a strong risk factor for Legionnaires' disease, although there have been only a few reports in HD patients. Because most patients on HD are anuric, the use of rapid assay kits to detect antigens in urine samples for the diagnosis of Legionnaires' disease is not always feasible. We suggest the use of clinical predictive tools or the loop-mediated isothermal amplification (LAMP) method, which can be applied for anuric patients, such as those on HD, with pneumonia.
Collapse
Affiliation(s)
- Akira Kawashima
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Daisuke Katagiri
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Isao Kondo
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Emi Sakamoto
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Minami Suzuki
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Yohei Arai
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Fumie Sato
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Manami Tada
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| | - Fumihiko Hinoshita
- Department of Nephrology, National Center for Global Health and Medicine, Japan
| |
Collapse
|
12
|
Olabarria G, Eletxigerra U, Rodriguez I, Bilbao A, Berganza J, Merino S. Highly sensitive and fast Legionella spp. in situ detection based on a loop mediated isothermal amplification technique combined to an electrochemical transduction system. Talanta 2020; 217:121061. [PMID: 32498831 DOI: 10.1016/j.talanta.2020.121061] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 04/15/2020] [Accepted: 04/17/2020] [Indexed: 12/25/2022]
Abstract
A rapid highly sensitive genosensor has been developed for monitoring the presence of Legionella spp. in different water systems (domestic hot water, heating/cooling systems or cooling towers) in order to avoid its spreading from the source of contamination. The genosensor integrates a loop mediated isothermal amplification (LAMP) reaction with an electrochemical transduction signal, producing a very simple, rapid to perform and cost effective method, suitable for in situ analyses. This approach detects as low as 10 fg of Legionella nucleic acid, corresponding to only 2 number copies of the bacteria. The use of an electrochemical redox-active double stranded DNA (dsDNA) intercalating molecule, known as methylen blue (MB), allows the immediate electrochemical reading during the DNA polymerization. The sensor can obtain quantitative results in 20 min with a correlation between the electrochemical data and Legionella spp. copy number (at a logarithmic scale) of r = -0.97. In conclusion, a fast, easy to use, and accurate electrochemical genosensor, with high precision, sensitivity, and specificity has been developed for in situ detection of Legionella spp. enabling real time decision making and improving significantly the current detection methods for the prevention and screening of Legionella.
Collapse
Affiliation(s)
- Garbiñe Olabarria
- GAIKER Technology Centre, Basque Research and Technology Alliance (BRTA). Parque Tecnológico, Edificio 202. 48170, Zamudio, Spain.
| | - Unai Eletxigerra
- Surface Chemistry and Nanotechnologies Unit, Tekniker, Eibar, 20600, Spain
| | - Isabel Rodriguez
- GAIKER Technology Centre, Basque Research and Technology Alliance (BRTA). Parque Tecnológico, Edificio 202. 48170, Zamudio, Spain
| | - Ainhoa Bilbao
- GAIKER Technology Centre, Basque Research and Technology Alliance (BRTA). Parque Tecnológico, Edificio 202. 48170, Zamudio, Spain
| | - Jesus Berganza
- GAIKER Technology Centre, Basque Research and Technology Alliance (BRTA). Parque Tecnológico, Edificio 202. 48170, Zamudio, Spain
| | - Santos Merino
- Surface Chemistry and Nanotechnologies Unit, Tekniker, Eibar, 20600, Spain; Departamento de Electricidad y Electrónica, Universidad Del País Vasco UPV/EHU, 48940, Leioa, Spain
| |
Collapse
|
13
|
Reuter C, Slesiona N, Hentschel S, Aehlig O, Breitenstein A, Csáki A, Henkel T, Fritzsche W. Loop-mediated amplification as promising on-site detection approach for Legionella pneumophila and Legionella spp. Appl Microbiol Biotechnol 2019; 104:405-415. [PMID: 31832709 DOI: 10.1007/s00253-019-10286-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/08/2019] [Accepted: 11/28/2019] [Indexed: 12/16/2022]
Abstract
Recently Legionella pneumophila is the main causative waterborne organism of severe respiratory infections. Additionally, other Legionella species are documented as human pathogens. In our work, we describe a rapid detection method which combines two advantages for sensitive and specific detection of the genus Legionella: the fast isothermal amplification method "Loop-mediated isothermal AMPlification" (LAMP), and a colorimetric detection method using the metal indicator hydroxynaphtol blue (HBN) which allows to determine an optical signal with a simple readout (with the naked eye). Moreover, we present two approaches for minimizing the assay volume using a stationary microchip LAMP and droplet digital-based LAMP (ddLAMP) as promising highly sensitive setups.
Collapse
Affiliation(s)
- Cornelia Reuter
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany.
| | - Nicole Slesiona
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Stefanie Hentschel
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Oliver Aehlig
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | | | - Andrea Csáki
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Thomas Henkel
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Wolfgang Fritzsche
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| |
Collapse
|
14
|
Ferguson RMW, Garcia‐Alcega S, Coulon F, Dumbrell AJ, Whitby C, Colbeck I. Bioaerosol biomonitoring: Sampling optimization for molecular microbial ecology. Mol Ecol Resour 2019; 19:672-690. [PMID: 30735594 PMCID: PMC6850074 DOI: 10.1111/1755-0998.13002] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 01/25/2019] [Accepted: 01/29/2019] [Indexed: 12/31/2022]
Abstract
Bioaerosols (or biogenic aerosols) have largely been overlooked by molecular ecologists. However, this is rapidly changing as bioaerosols play key roles in public health, environmental chemistry and the dispersal ecology of microbes. Due to the low environmental concentrations of bioaerosols, collecting sufficient biomass for molecular methods is challenging. Currently, no standardized methods for bioaerosol collection for molecular ecology research exist. Each study requires a process of optimization, which greatly slows the advance of bioaerosol science. Here, we evaluated air filtration and liquid impingement for bioaerosol sampling across a range of environmental conditions. We also investigated the effect of sampling matrices, sample concentration strategies and sampling duration on DNA yield. Air filtration using polycarbonate filters gave the highest recovery, but due to the faster sampling rates possible with impingement, we recommend this method for fine -scale temporal/spatial ecological studies. To prevent bias for the recovery of Gram-positive bacteria, we found that the matrix for impingement should be phosphate-buffered saline. The optimal method for bioaerosol concentration from the liquid matrix was centrifugation. However, we also present a method using syringe filters for rapid in-field recovery of bioaerosols from impingement samples, without compromising microbial diversity for high -throughput sequencing approaches. Finally, we provide a resource that enables molecular ecologists to select the most appropriate sampling strategy for their specific research question.
Collapse
Affiliation(s)
| | | | - Frederic Coulon
- School of Water, Energy and EnvironmentCranfield UniversityCranfieldUK
| | | | - Corinne Whitby
- School of Biological SciencesUniversity of EssexColchesterUK
| | - Ian Colbeck
- School of Biological SciencesUniversity of EssexColchesterUK
| |
Collapse
|
15
|
Moosavian M, Seyed-Mohammadi S, Saki M, Shahi F, Khoshkholgh Sima M, Afshar D, Barati S. Loop-mediated isothermal amplification for detection of Legionella pneumophila in respiratory specimens of hospitalized patients in Ahvaz, southwest Iran. Infect Drug Resist 2019; 12:529-534. [PMID: 30881058 PMCID: PMC6402708 DOI: 10.2147/idr.s198099] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Background Legionnaires’ disease is an important public health problem that can cause substantial mortality and morbidity. Legionnaires’ disease-risk estimation may be compromised by uncertainties in Legionella-detection methods. The aim of this study was the detection of L. pneumophila in respiratory specimens of hospitalized patients with respiratory symptoms by culture, PCR, and loop-mediated isothermal amplification (LAMP) methods. Methods Sputum and bronchoalveolar lavage samples were obtained from patients with pneumonia admitted to teaching hospitals in Ahvaz, Iran from June 2016 to March 2017. Isolation of Legionella spp. was done by culturing the samples directly onto buffered charcoal–yeast extract and modified Wadowsky–Yee agar medium. Then, PCR and LAMP assays were performed for detection of L. pneumophila via its mip gene in respiratory specimens. Results A total of 100 respiratory specimens were collected. Our results showed that 1% of the samples were culture positive for Legionella spp., and 3% and 7% of samples were positive for L. pneumophila using the mip gene on PCR and LAMP assays, respectively. Conclusion Legionnaires’ disease should be considered in the diagnosis of pulmonary infectious diseases. Also, the LAMP assay is a faster method with higher sensitivity and specificity than conventional methods, such as PCR and culture, for laboratory diagnosis of Legionnaires’ disease.
Collapse
Affiliation(s)
- Mojtaba Moosavian
- Infectious and Tropical Diseases Research Center, Health Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.,Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran,
| | - Sakineh Seyed-Mohammadi
- Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, .,Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran,
| | - Morteza Saki
- Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, .,Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran,
| | - Fatemeh Shahi
- Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, .,Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran,
| | - Mahtab Khoshkholgh Sima
- Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran,
| | - Davoud Afshar
- Department of Microbiology and Virology, School of Medicine, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Sara Barati
- Department of Pathobiology, School of Veterinary, University of Shahid Chamran, Ahvaz, Iran
| |
Collapse
|
16
|
Kersting S, Rausch V, Bier FF, von Nickisch-Rosenegk M. A recombinase polymerase amplification assay for the diagnosis of atypical pneumonia. Anal Biochem 2018; 550:54-60. [DOI: 10.1016/j.ab.2018.04.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Revised: 04/11/2018] [Accepted: 04/12/2018] [Indexed: 12/15/2022]
|
17
|
Moriguchi S, Abe M, Kimura M, Yoshino C, Baba M, Okada C, Izutsu K, Taniguchi S, Araoka H, Yoneyama A. The Diagnosis of Legionella pneumophila Serogroup 5 Bacteremic Pneumonia during Severe Neutropenia Using Loop-mediated Isothermal Amplification. Intern Med 2018; 57:1045-1048. [PMID: 29269681 PMCID: PMC5919869 DOI: 10.2169/internalmedicine.9810-17] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Accepted: 07/31/2017] [Indexed: 11/13/2022] Open
Abstract
A 60-year-old man developed pneumonia after undergoing autologous peripheral blood stem cell transplantation for diffuse large-B cell lymphoma. A urinary antigen test and sputum culture were both negative for Legionella pneumophila; however, a sputum sample that was examined by loop-mediated isothermal amplification (LAMP) was positive for Legionella spp. On admission, the results of blood culturing using a BACTEC system were negative for 7 days. However, L. pneumophila serogroup 5 was detected in a blood subculture using WYOα medium. The patient was successfully treated with a fluoroquinolone-based regimen. LAMP is useful for the diagnosis of Legionella spp.
Collapse
Affiliation(s)
| | - Masahiro Abe
- Department of Infectious Diseases, Toranomon Hospital, Japan
| | | | - Chiemi Yoshino
- Department of Infectious Diseases, Toranomon Hospital, Japan
| | - Masaru Baba
- Department of Infectious Diseases, Toranomon Hospital, Japan
| | - Chikako Okada
- Department of Infectious Diseases, Toranomon Hospital, Japan
| | - Koji Izutsu
- Department of Hematology, Toranomon Hospital, Japan
| | | | - Hideki Araoka
- Department of Infectious Diseases, Toranomon Hospital, Japan
| | - Akiko Yoneyama
- Department of Infectious Diseases, Toranomon Hospital, Japan
| |
Collapse
|
18
|
Nakayama T, Yamazaki T, Yo A, Tone K, Mahdi Alshahni M, Fujisaki R, Makimura K. Detection of Fungi from an Indoor Environment using Loop-mediated Isothermal Amplification (LAMP) Method. Biocontrol Sci 2018; 22:97-104. [PMID: 28659561 DOI: 10.4265/bio.22.97] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) is a useful DNA detection method with high specificity and sensitivity. The LAMP reaction is carried out within a short time at a constant temperature without the need for thermal cycling. We developed a LAMP primer set for detecting a wide range of fungi by aligning the sequences of the large subunit ribosomal RNA gene of Candida albicans (Ascomycota), Cryptococcus neoformans (Basidiomycota), and Mucor racemosus (Mucorales). The threshold of C. albicans rDNA as template with our LAMP primer set was in the range of 10-100 copies per a reaction. In this study, we evaluated the correlation between colony forming units (CFU) and LAMP detection rate using the LAMP method for environmental fungi. The LAMP method should be a useful means of detecting fungi in indoor environments, disaster areas, or even in confined manned spacecraft to prevent allergies or infections caused by fungi.
Collapse
Affiliation(s)
- Takako Nakayama
- Division of Clinical Laboratory Medicine, Graduate School of Medical Care and Technology
| | - Takashi Yamazaki
- Laboratory of Space and Environmental Medicine, Graduate School of Medicine.,General Medical Education Research Center
| | - Ayaka Yo
- Laboratory of Space and Environmental Medicine, Graduate School of Medicine
| | - Kazuya Tone
- Laboratory of Space and Environmental Medicine, Graduate School of Medicine
| | | | - Ryuichi Fujisaki
- Emergency Room (ER), Department of Emergency -Medicine, Faculty of Medicine, Teikyo University
| | - Koichi Makimura
- Division of Clinical Laboratory Medicine, Graduate School of Medical Care and Technology.,Laboratory of Space and Environmental Medicine, Graduate School of Medicine.,General Medical Education Research Center
| |
Collapse
|
19
|
Samhan FA, Stedtfeld TM, Waseem H, Williams MR, Stedtfeld RD, Hashsham SA. On-filter direct amplification of Legionella pneumophila for rapid assessment of its abundance and viability. WATER RESEARCH 2017; 121:162-170. [PMID: 28527390 PMCID: PMC5525548 DOI: 10.1016/j.watres.2017.05.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 05/08/2017] [Accepted: 05/12/2017] [Indexed: 05/14/2023]
Abstract
Guidelines and regulations to control Legionella pneumophila in cooling water systems of large buildings are evolving due to the increasing number of outbreaks. Rapid, on-site, simple, and sensitive quantification methods that are also able to assess viability may be extremely useful in monitoring and control. Culture-based methods for measuring L. pneumophila may take 4-10 days and qPCR-based methods are also slow, requiring at least a day from sample to result, albeit mainly due to the need for sample transport to a centralized laboratory. This study reports a rapid isothermal amplification method for L. pneumophila concentration and detection with live/dead differentiation under field conditions. Using an on-filter direct amplification (i.e., amplification of cells without DNA extraction and purification) approach with propidium monoazide (PMA), and a real time isothermal amplification platform (Gene-Z), L. pneumophila could be detected in 1-2 h at ∼1 cfu/100 ml of tap water. Signature sequences from 16S rRNA and cadA genes were used as genetic markers for L. pneumophila and loop-mediated isothermal amplification (LAMP) primers were designed using Primer Explorer V4. Result were also compared with direct amplification of cells spiked into distilled, tap, and cooling water samples as well as extracted DNA by qPCR. This method may be useful to managers of cooling water systems in large buildings for rapid detection of L. pneumophila. The overall approach of on-site sample concentration, on-filter amplification, and live/dead differentiation may be extended to other organisms where analytical sensitivity and speed are equally important.
Collapse
Affiliation(s)
- Farag A Samhan
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA
| | - Tiffany M Stedtfeld
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA
| | - Hassan Waseem
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA
| | - Maggie R Williams
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA
| | - Robert D Stedtfeld
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA
| | - Syed A Hashsham
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA; Center for Microbial Ecology, Michigan State University, East Lansing, MI, USA.
| |
Collapse
|
20
|
Pierre DM, Baron J, Yu VL, Stout JE. Diagnostic testing for Legionnaires' disease. Ann Clin Microbiol Antimicrob 2017; 16:59. [PMID: 28851372 PMCID: PMC5576257 DOI: 10.1186/s12941-017-0229-6] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 08/01/2017] [Indexed: 11/10/2022] Open
Abstract
Legionnaires' disease is commonly diagnosed clinically using a urinary antigen test. The urinary antigen test is highly accurate for L. pneumophila serogroup 1, however other diagnostic tests should also be utilized in conjunction with the urinary antigen as many other Legionella species and serogroups are pathogenic. Culturing of patient specimens remains the gold standard for diagnosis of Legionnaires' disease. Selective media, BYCE with the addition of antibiotics, allows for a high sensitivity and specificity. Culturing can identify all species and serogroups of Legionella. A major benefit of culturing is that it provides the recovery of a patient isolate, which can be used to find an environmental match. Other diagnostic tests, including DFA and molecular tests such as PCR and LAMP, are useful tests to supplement culturing. Molecular tests provide much more rapid results in comparison to culture, however these tests should not be a primary diagnostic tool given their lower sensitivity and specificity in comparison to culturing. It is recommended that all laboratories develop the ability to culture patient specimens in-house with the selective media.
Collapse
Affiliation(s)
- David M. Pierre
- Special Pathogens Laboratory, 1401 Forbes Avenue, Pittsburgh, PA 15219 USA
| | - Julianne Baron
- Special Pathogens Laboratory, 1401 Forbes Avenue, Pittsburgh, PA 15219 USA
- University of Pittsbrugh, Pittsburgh, Pennsylvania 15219 United States
| | - Victor L. Yu
- Special Pathogens Laboratory, 1401 Forbes Avenue, Pittsburgh, PA 15219 USA
- Department of Medicine, School of Medicine, University of Pittsburgh, Pittsburgh, PA USA
| | - Janet E. Stout
- Special Pathogens Laboratory, 1401 Forbes Avenue, Pittsburgh, PA 15219 USA
- University of Pittsbrugh, Pittsburgh, Pennsylvania 15219 United States
| |
Collapse
|
21
|
Xiong L, Yan H, Shi L, Mo Z. Antibiotic susceptibility of Legionella strains isolated from public water sources in Macau and Guangzhou. JOURNAL OF WATER AND HEALTH 2016; 14:1041-1046. [PMID: 27959883 DOI: 10.2166/wh.2016.056] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The purpose of this study was to investigate the susceptibility of waterborne strains of Legionella to eight antimicrobials commonly used in legionellosis therapy. The minimum inhibitory concentrations (MICs) of 66 environmental Legionella strains, isolated from fountains and cooling towers of public facilities (hotels, schools, and shopping malls) in Macau and Guangzhou, were tested using the microdilution method in buffered yeast extract broth. The MIC50/MIC90 values for erythromycin, cefotaxime (CTX), doxycycline (DOC), minocycline (MIN), azithromycin, ciprofloxacin, levofloxacin (LEV), and moxifloxacin were 0.125/0.5 mg/L, 4/8 mg/L, 8/16 mg/L, 4/8 mg/L, 0.125/0.5 mg/L, 0.031/0.031 mg/L, 0.031/0.031 mg/L, and 0.031/0.062 mg/L, respectively. Legionella isolates were inhibited by either low concentrations of macrolides and fluoroquinolones, or high concentrations of CTX and tetracycline drugs. LEV was the most effective drug against different Legionella species and serogroups of L. pneumophila isolates. The latter were inhibited in decreasing order by MIN > CTX >DOC, while non-L. pneumophila isolates were inhibited by CTX> MIN >DOC. In this study, we evaluated drug resistance of pathogenic bacteria from the environment. This may help predict the emergence of drug resistance, improve patient outcomes, and reduce hospitalization costs.
Collapse
Affiliation(s)
- Lina Xiong
- School of Food Science and Technology, South China University of Technology, No. 381, Wushan Road, TianHe District, Guangzhou, Guangdong 510641, China
| | - He Yan
- School of Food Science and Technology, South China University of Technology, No. 381, Wushan Road, TianHe District, Guangzhou, Guangdong 510641, China
| | - Lei Shi
- School of Food Science and Technology, South China University of Technology, No. 381, Wushan Road, TianHe District, Guangzhou, Guangdong 510641, China
| | - Ziyao Mo
- State Key Laboratory of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Institute of Respiratory Disease, No. 151, YanJiang Xi Road, YueXiu District, Guangzhou, Guangdong 510120, China E-mail:
| |
Collapse
|
22
|
Janczarek M, Palusińska-Szysz M. PCR method for the rapid detection and discrimination of Legionella spp. based on the amplification of pcs, pmtA, and 16S rRNA genes. J Appl Genet 2015; 57:251-61. [PMID: 26423783 DOI: 10.1007/s13353-015-0317-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 08/18/2015] [Accepted: 09/14/2015] [Indexed: 10/23/2022]
Abstract
Legionella bacteria are organisms of public health interest due to their ability to cause pneumonia (Legionnaires' disease) in susceptible humans and their ubiquitous presence in water supply systems. Rapid diagnosis of Legionnaires' disease allows the use of therapy specific for the disease. L. pneumophila serogroup 1 is the most common cause of infection acquired in community and hospital environments. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this work, simplex and duplex PCR assays with the use of new molecular markers pcs and pmtA involved in phosphatidylcholine synthesis were specified for rapid and cost-efficient identification and distinguishing Legionella species. The sets of primers developed were found to be sensitive and specific for reliable detection of Legionella belonging to the eight most clinically relevant species. Among these, four primer sets I, II, VI, and VII used for duplex-PCRs proved to have the highest identification power and reliability in the detection of the bacteria. Application of this PCR-based method should improve detection of Legionella spp. in both clinical and environmental settings and facilitate molecular typing of these organisms.
Collapse
Affiliation(s)
- Monika Janczarek
- Department of Genetics and Microbiology, Institute of Microbiology and Biotechnology, Maria Curie-Sklodowska University, Akademicka St. 19, 20-033, Lublin, Poland
| | - Marta Palusińska-Szysz
- Department of Genetics and Microbiology, Institute of Microbiology and Biotechnology, Maria Curie-Sklodowska University, Akademicka St. 19, 20-033, Lublin, Poland.
| |
Collapse
|
23
|
Mercante JW, Winchell JM. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clin Microbiol Rev 2015; 28:95-133. [PMID: 25567224 PMCID: PMC4284297 DOI: 10.1128/cmr.00029-14] [Citation(s) in RCA: 223] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic "blind spot" for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed.
Collapse
Affiliation(s)
- Jeffrey W Mercante
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Jonas M Winchell
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| |
Collapse
|
24
|
Song L, Li J, Hou S, Li X, Chen S. Establishment of loop-mediated isothermal amplification (LAMP) for rapid detection of Brucella spp. and application to milk and blood samples. J Microbiol Methods 2012; 90:292-7. [PMID: 22688008 DOI: 10.1016/j.mimet.2012.05.024] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Revised: 05/31/2012] [Accepted: 05/31/2012] [Indexed: 10/28/2022]
Abstract
Brucella spp. are facultative intracellular bacteria that infect humans and animals. In this study, the loop-mediated isothermal amplification (LAMP) was used to detect the Brucella-specific gene omp25. Reaction conditions were optimized as temperature 65°C, reaction time 60 min, Mg(2+) concentration 8.0 mmol/L, polymerase content Bst DNA, 0.5 μL, deoxyribonucleotide concentration 1.6 mmol/L, and inner/outer primer ratio 1:8. The LAMP method was evaluated with 4 Brucella species and 29 non-Brucella bacteria species. Positive reactions were observed on all the 4 Brucella species but not on any non-Brucella species. The limit of detection of the LAMP method was 3.81 CFU Brucella spp. Using the LAMP method, 7 of 110 raw milk samples and 5 of 59 sheep blood samples were detected positive of Brucella spp. Results indicated that LAMP is a fast, specific, sensitive, inexpensive, and suitable method for diagnosis of Brucella spp. infection.
Collapse
Affiliation(s)
- Liuyan Song
- Department of Microbiology, Guangzhou Center for Disease Control and Prevention, Guangzhou, China
| | | | | | | | | |
Collapse
|