1
|
Hjorth MH, Mechlenburg I, Soballe K, Rømer L, Jakobsen SS, Stilling M. The anatomical location of cystic pseudotumors and muscle atrophy in metal-on-metal resurfacing hip arthroplasty is related to the surgical approach used for implantation. A subgroup analyses of a randomized controlled trial. Arch Orthop Trauma Surg 2023; 143:5967-5976. [PMID: 36802238 DOI: 10.1007/s00402-023-04788-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 01/22/2023] [Indexed: 02/23/2023]
Abstract
BACKGROUND Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."
Collapse
Affiliation(s)
- Mette Holm Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark.
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| | - Lone Rømer
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Stig Storgaard Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| |
Collapse
|
2
|
The AIUM Practice Parameter for the Performance of the Musculoskeletal Ultrasound Examination. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:E23-E35. [PMID: 37130137 DOI: 10.1002/jum.16228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 03/17/2023] [Indexed: 05/03/2023]
|
3
|
Bellamkonda KS, Tonnessen BH, Molho DA, Lindskog D, Wiznia D. Retroperitoneal Approach for Excision of Wear-Debris Pseudotumor: A Case Report. JBJS Case Connect 2021; 11:01709767-202103000-00030. [PMID: 33730003 DOI: 10.2106/jbjs.cc.20.00166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE Pelvic pseudotumors may occur as a reaction to wear-debris after hip arthroplasty and are rarely treated with surgery. We describe an instance in which a pelvic pseudotumor along the iliopsoas muscle tendon sheath was debulked using a retroperitoneal approach in a patient presenting for treatment of a prosthetic hip infection. The patient recovered uneventfully and was ambulatory with a new hip prosthesis at 3 months after procedure. CONCLUSIONS Retroperitoneal exposure provided safe, excellent exposure to a wear-debris pelvic pseudotumor in this case.
Collapse
Affiliation(s)
| | - Britt H Tonnessen
- Division of Vascular Surgery, Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| | - David A Molho
- Department of Orthopaedics, Yale School of Medicine, New Haven, Connecticut
| | - Dieter Lindskog
- Department of Orthopaedics, Yale School of Medicine, New Haven, Connecticut
| | - Daniel Wiznia
- Department of Orthopaedics, Yale School of Medicine, New Haven, Connecticut
| |
Collapse
|
4
|
Metal-on-Metal Total Hip Revisions: Pearls and Pitfalls. J Arthroplasty 2020; 35:S68-S72. [PMID: 32081501 DOI: 10.1016/j.arth.2020.01.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/07/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND At the turn of the 21st century, there was a re-emergence of metal-on-metal (MoM) articulation with 35% of all total hip arthroplasty implants having MoM articulation. Approximately 10 years after its peak use, MoM articulation began to decrease dramatically as revisions became more apparent because of adverse reaction to metal debris. Today, there are surveillance guidelines and reconstructive clinical pearls a surgeon should recognize. METHODS This article gives a literature-based overview of clinical pearls and discusses how to avoid pitfalls when performing revision of a metal-on-metal total hip arthroplasty. RESULTS Patients with MoM can be risk-stratified based on symptom, implant, and testing variables. Those patients who are symptomatic and/or develop adverse reaction to metal debris with local tissue destruction will require a revision. The revision of MoM can be challenging due to bone and soft tissue destruction. Constraint may be needed in cases of abductor deficiency. CONCLUSION Although MoM implants for THA have declined significantly, surgeons are still faced with the revision burden from a decade of high use. Risk stratification tools are available to aid in revision decision making, and the surgeon should be prepared to address the challenges these revisions present.
Collapse
|
5
|
Kovochich M, Finley BL, Novick R, Monnot AD, Donovan E, Unice KM, Fung ES, Fung D, Paustenbach DJ. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review. Crit Rev Toxicol 2019; 48:853-901. [DOI: 10.1080/10408444.2018.1563048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
6
|
Kilb BKJ, Kurmis AP, Parry M, Sherwood K, Keown P, Masri BA, Duncan CP, Garbuz DS. Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs. Clin Orthop Relat Res 2018; 476. [PMID: 29529651 PMCID: PMC6259707 DOI: 10.1007/s11999.0000000000000028] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Once touted as the future of hip arthroplasty, metal-on-metal (MoM) bearing surfaces have fallen sharply from favor with the emergence of a strong body of evidence demonstrating unacceptably high premature implant failure rates. The previously unpredictable development of adverse local tissue reactions (ALTRs) has been a substantive contributor to this. Although the underlying pathophysiology of these so-called "pseudotumors" is now well understood, the fundamental predisposing patient risk factors have remained elusive. QUESTIONS/PURPOSES The aim of this research, as a clinical-genotype correlation analysis, was to identify specific alleles (genes) associated with the development of ALTRs in patients with in situ MoM THAs. METHODS A case-control study of patients who received a large-head, primary MoM THA between 2005 and 2008 was performed with a minimum followup of 5 years. Twenty-six patients who had undergone revision of a primary MoM THA secondary to symptomatic ALTRs were recruited. The mean timeframe from primary MoM THA to symptomatic revision was 5.5 years (range, 1-10 years). Twenty-eight control subjects were randomly selected asymptomatic patients with no evidence of ALTRs on protocol-specific screening. Baseline demographics and high-resolution genotype (human leukocyte antigen [HLA] Class II) were collected for all patients. Cohorts were similar with respect to age at the time of primary MoM THA (mean, 54.8 versus 54.9 years, p = 0.95) and serum cobalt (mean, 5.5 versus 8.5 μg/L, p = 0.09) and chromium concentrations (mean, 2.9 versus 4.2 μg/L, p = 0.27). The association between genotype and revision surgery secondary to ALTRs was determined with gender as a covariate. RESULTS The prevalence of the risk genotype was 30% (16 of 54) among the entire cohort. Adjusting for sex, the odds of revision were 6.1 times greater among patients with the risk genotype present than among patients without (95% confidence interval [CI], 1.5-25.4; p = 0.01). Among females, the specificity of the risk genotype was 1.0 (95% CIexact, 0.5-1.0; pexact = 0.03), and for males, it was 0.8 (95% CIexact, 0.6-0.9; pexact < 0.01). CONCLUSIONS The findings of this study suggest that, among patients with a primary MoM THA, allelic variation within the HLA Class II loci may be a strong, independent risk factor associated with the need for subsequent revision surgery secondary to pseudotumor formation. CLINICAL RELEVANCE Given the hypothesis-generating nature of this novel undertaking, confirmatory prospective clinical studies are required to further elucidate this correlation and to explore the clinical utility of targeted genetic screening in this specific population. This research may, however, represent a key missing piece in the puzzle that is metal ion-induced pseudotumor formation.
Collapse
Affiliation(s)
- Brett K J Kilb
- B. K. J. Kilb, A. P. Kurmis, M. Parry, B. A. Masri, C. P. Duncan, D. S., Garbuz Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada K. Sherwood, P. Keown Department of Pathology (&) Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada P. Keown, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada A. P. Kurmis, Discipline of Medical Specialties, University of Adelaide, Adelaide, SA, Australia
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Matharu GS, Judge A, Eskelinen A, Murray DW, Pandit HG. What is appropriate surveillance for metal-on-metal hip arthroplasty patients? Acta Orthop 2018; 89:29-39. [PMID: 29105547 PMCID: PMC5810829 DOI: 10.1080/17453674.2017.1398011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory authorities recommending regular surveillance, even for asymptomatic individuals. However, these recommendations are not evidence-based and are very costly. The rapidly evolving evidence base requires an update regarding the investigation and management of MoMHA patients. This article is the first of 2 (the second article in this series will consider the threshold for performing revision, and the outcomes following ARMD revision surgery: Matharu et al., Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: A clinical update. Acta Orthop 2018; in press), and considers the various investigative modalities used during surveillance, with specific focus on blood metal ion sampling and cross-sectional imaging. No single investigation can universally be used during MoMHA patient surveillance. Recent studies have now provided important information on interpreting blood metal ions (effective in identifying patients at low risk of problems), clarifying the roles of cross-sectional imaging (reserve combined ultrasound and MARS-MRI for complex cases), and providing parameters to safely exclude many asymptomatic patients from regular surveillance. This information will be useful when designing future surveillance protocols for MoMHA patients.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK;,Correspondence:
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | | | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| |
Collapse
|
8
|
O'Connor SM, Wobker SE, Cardona DM, Eward W, Esther RJ, Dodd LG. Iatrogenic lesions of soft tissue and bone. Semin Diagn Pathol 2017; 35:208-217. [PMID: 29110897 DOI: 10.1053/j.semdp.2017.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- S M O'Connor
- Department of Pathology and Laboratory Medicine, University of North Carolina Chapel Hill, United States
| | - S E Wobker
- Department of Pathology and Laboratory Medicine, University of North Carolina Chapel Hill, United States
| | - D M Cardona
- Department of Pathology, Duke University, Durham, NC, United States
| | - W Eward
- Division of Oncology, Department of Orthopaedic Surgery, Duke University, Durham, NC, United States
| | - R J Esther
- Department of Orthopaedic Surgery, University of North Carolina Chapel Hill, United States
| | - L G Dodd
- Department of Pathology and Laboratory Medicine, University of North Carolina Chapel Hill, United States.
| |
Collapse
|
9
|
Adverse tissue reactions after total hip arthroplasty. Ann Diagn Pathol 2017; 27:83-87. [DOI: 10.1016/j.anndiagpath.2016.07.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Accepted: 07/27/2016] [Indexed: 01/03/2023]
|
10
|
Teo WZW, Schalock PC. Metal Hypersensitivity Reactions to Orthopedic Implants. Dermatol Ther (Heidelb) 2017; 7:53-64. [PMID: 27995484 PMCID: PMC5336431 DOI: 10.1007/s13555-016-0162-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Indexed: 01/08/2023] Open
Abstract
Total hip and knee replacement surgery using metal alloy devices is common. Type IV allergic reactions to these implants occur, though infrequently. While uncommon, peri-implant metal allergic reactions may cause significant morbidity for the affected individual-including aseptic loosening, pseudotumor formation and frank device failure. It is challenging to predict who will have these reactions, even in those with established pre-implant metal allergy. At this time, the scientific literature clearly supports few conclusions. Despite this, we believe several conclusions can be made: routine pre-implant testing in asymptomatic individuals is not indicated; listen to patient's concerns about metal allergy if the concern arises; patch testing is probably the best pre- and post-implant screening test; post-implantation testing is controversial and even positive LTT or patch test does not definitively diagnose morbidity from a metal allergy; and complete recovery following revision placement of an immunologically inert device is diagnostic. More research is needed to scientifically approach this issue.
Collapse
Affiliation(s)
- Wendy Z W Teo
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA
| | - Peter C Schalock
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
| |
Collapse
|
11
|
Craig R, Vlychou M, McCarthy CL, Gibbons CLMH, Athanasou NA. Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma. Skeletal Radiol 2017; 46:967-974. [PMID: 28271180 PMCID: PMC5438826 DOI: 10.1007/s00256-017-2610-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 01/19/2017] [Accepted: 02/14/2017] [Indexed: 02/08/2023]
Abstract
Pseudotumours are well recognised as a complication of metal-on-metal hip arthroplasties and are thought to develop on the basis of an innate and adaptive immune response to cobalt-chrome (Co-Cr) wear particles. We report a case of a large pseudotumour that developed following a knee endoprosthetic replacement (EPR) undertaken for Ewing sarcoma. The lesion contained necrotic and degenerate connective tissue in which there were numerous scattered metal wear-containing macrophages, eosinophil polymorphs, lymphocytes, plasma cells and aseptic lymphocyte-dominated vascular-associated lesion-like lymphoid aggregates. Metal ion levels were elevated. No evidence of infection or tumour was noted and it was concluded that the lesion was most likely an inflammatory pseudotumour developing on the basis of an innate and adaptive immune response to components of Co-Cr metal wear derived from the knee EPR.
Collapse
Affiliation(s)
- Richard Craig
- Department of Orthopaedics, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | - Marianna Vlychou
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | - Catherine L McCarthy
- Department of Radiology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | | | - N A Athanasou
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK.
| |
Collapse
|
12
|
Shah A, Botchu R, Dunlop D, Davies AM, James SL. Metal-on-Metal Total Hip Arthroplasty Associated with Adverse Local Tissue Reaction and Pseudoaneurysm of the Superior Gluteal Artery: A Case Report and Literature Review. Surg J (N Y) 2016; 2:e113-e118. [PMID: 28825003 PMCID: PMC5553479 DOI: 10.1055/s-0036-1593855] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Accepted: 10/03/2016] [Indexed: 12/14/2022] Open
Abstract
Adverse local tissue reaction (ALTR) and pseudoaneurysm formation are rare but known complications following metal-on-metal hip total hip arthroplasty (THA). We report the first known case in the English literature of a concurrent unilateral ALTR and pseudoaneurysm of the superior gluteal artery in the same patient. Following minimal rise in serum metal ions, an ultrasound of the right hip demonstrated an avascular solid/cystic lesion anterolaterally in keeping with an ALTR. More posterolaterally, a second discrete thick-walled cystic lesion was identified. Doppler interrogation demonstrated a “yin yang” pattern suggestive of a pseudoaneurysm. Magnetic resonance imaging confirmed the presence of an anterolateral periarticular lesion with a second discrete lesion within the gluteus medius. Subsequent computed tomography angiography confirmed the presence of arterial contrast blush within the posterior gluteal lesion adjacent to the superior gluteal artery. The patient remains asymptomatic and is being managed conservatively. We review the imaging characteristics of ALTR and pseudoaneurysm occurring post-THA. When a complex solid/cystic lesion is encountered in a patient with a THA, radiologists must ensure that the lesion is interrogated with color Doppler to confidently distinguish a pseudotumor from a pseudoaneurysm. This information is vital to the surgeon to avoid unexpected hemorrhage if revision joint replacement surgery is being contemplated.
Collapse
Affiliation(s)
- Amit Shah
- Department of Musculoskeletal Radiology, Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Rajesh Botchu
- Department of Musculoskeletal Radiology, Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - David Dunlop
- Department of Orthopaedics, Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - A Mark Davies
- Department of Musculoskeletal Radiology, Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Steven L James
- Department of Musculoskeletal Radiology, Royal Orthopaedic Hospital, Birmingham, United Kingdom
| |
Collapse
|
13
|
Kwon YM, Khormaee S, Liow MHL, Tsai TY, Freiberg AA, Rubash HE. Asymptomatic Pseudotumors in Patients with Taper Corrosion of a Dual-Taper Modular Femoral Stem: MARS-MRI and Metal Ion Study. J Bone Joint Surg Am 2016; 98:1735-1740. [PMID: 27869625 DOI: 10.2106/jbjs.15.01325] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Modularity in total hip arthroplasty facilitates intraoperative restoration of patient anatomy. Although dual-taper modular total hip arthroplasty offers potential advantages for optimizing the hip center of rotation, it has been associated with modular taper corrosion. This corrosion has led to adverse local tissue reactions (pseudotumors) at the neck-stem junction and elevated metal-ion levels. However, the occurrence of taper-corrosion-related pseudotumors in patients who remain asymptomatic following total hip arthroplasty with a dual-taper modular femoral stem remains largely unknown. The aims of this study were (1) to determine the prevalence of asymptomatic pseudotumors by utilizing metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) and (2) compare serum metal-ion levels between symptomatic and asymptomatic patients with a dual-taper modular stem total hip replacement. METHODS We performed a retrospective cross-sectional study of 97 consecutive patients who had been treated with a dual-taper modular femoral stem total hip arthroplasty. Eighty-three patients were stratified into symptomatic and asymptomatic groups and evaluated with MARS-MRI, measurement of serum metal-ion levels, and the University of California at Los Angeles (UCLA) functional hip score. RESULTS The prevalence of pseudotumors as determined with MARS-MRI was 15% in our asymptomatic patients and 36% in the overall cohort. The median serum cobalt level and cobalt/chromium ratio were significantly higher in patients with a pseudotumor than in those without a pseudotumor (8.0 versus 2.0 μg/L [p = 0.004] and 10.3 versus 2.4 μg/L [p = 0.012], respectively). However, there was no significant difference in the serum cobalt level or cobalt/chromium ratio between symptomatic patients with a pseudotumor and asymptomatic patients with a pseudotumor (7.6 versus 6.2 μg/L [p = 0.37] and 8.3 versus 10.6 μg/L [p = 0.46], respectively). The UCLA scores of asymptomatic patients with a pseudotumor were similar to those of patients without a pseudotumor (6.7 versus 6.6). CONCLUSIONS The prevalence of asymptomatic taper-corrosion-related pseudotumors on MARS-MRI in this study demonstrated that the absence of symptoms does not exclude the presence of adverse local tissue reactions. Elevated cobalt levels and cobalt/chromium ratios were associated with the presence of pseudotumors in asymptomatic and symptomatic patients. Cross-sectional imaging such as MARS-MRI is indicated for patients with elevated metal-ion levels. A longitudinal study is required to determine whether asymptomatic patients with taper-corrosion-related pseudotumors will develop symptoms with time. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Sariah Khormaee
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Tsung-Yuan Tsai
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Andrew A Freiberg
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Harry E Rubash
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
14
|
Berber R, Khoo M, Cook E, Guppy A, Hua J, Miles J, Carrington R, Skinner J, Hart A. Muscle atrophy and metal-on-metal hip implants: a serial MRI study of 74 hips. Acta Orthop 2015; 86:351-7. [PMID: 25588091 PMCID: PMC4443469 DOI: 10.3109/17453674.2015.1006981] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. PATIENTS AND METHODS We retrospectively reviewed 74 hips in 56 patients (32 of them women) using serial MRI. Median age was 59 (23-83) years. The median time post-implantation was 83 (35-142) months, and the median interval between scans was 11 months. Hip muscles were scored using the Pfirrmann system. The mean scores for muscle atrophy were compared between the first and second MRI scans. Blood cobalt and chromium concentrations were determined. RESULTS The median blood cobalt was 6.84 (0.24-90) ppb and median chromium level was 4.42 (0.20-45) ppb. The median Oxford hip score was 34 (5-48). The change in the gluteus minimus mean atrophy score between first and second MRI was 0.12 (p = 0.002). Mean change in the gluteus medius posterior portion (unaffected by surgical approach) was 0.08 (p = 0.01) and mean change in the inferior portion was 0.10 (p = 0.05). Mean pseudotumor grade increased by 0.18 (p = 0.02). INTERPRETATION Worsening muscle atrophy and worsening pseudotumor grade occur over a 1-year period in a substantial proportion of patients with MOM hip implants. Serial MRI helps to identify those patients who are at risk of developing worsening soft-tissue pathology. These patients should be considered for revision surgery before irreversible muscle destruction occurs.
Collapse
Affiliation(s)
- Reshid Berber
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | - Michael Khoo
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | - Erica Cook
- University of Bedfordshire,Park Square, Luton, Bedfordshire
| | - Andrew Guppy
- University of Bedfordshire,Park Square, Luton, Bedfordshire
| | - Jia Hua
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex,Middlesex University London, The Burroughs, London, UK
| | - Jonathan Miles
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | | | - John Skinner
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | - Alister Hart
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| |
Collapse
|
15
|
What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clin Orthop Relat Res 2015; 473:477-84. [PMID: 25085361 PMCID: PMC4294930 DOI: 10.1007/s11999-014-3824-2] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Soft tissue masses, or "pseudotumors," around metal-on-metal total hip arthroplasty (MoM THA) have been reported frequently; however, their prevalence remains unknown. Several risk factors, including elevated metal ion levels, have been associated with the presence of pseudotumor, although this remains controversial. QUESTIONS/PURPOSES The goals of this study were to (1) determine the prevalence of pseudotumors after large-diameter head MoM THA; (2) identify risk factors associated with pseudotumor formation and elevated metal ion levels; and (3) determine the early failure rate of large-diameter MoM THA. METHODS Between December 2005 and November 2012, 258 hips (215 patients) underwent large-diameter head primary MoM THA at our institution. Clinical followup was obtained in 235 hips (91%). Using an inclusion criteria of a minimum followup of 1 year, a subset of 191 hips (mean followup, 4 years; range, 1-7 years) was recruited for high-resolution ultrasound screening for the presence of pseudotumor. Whole blood cobalt and chromium ion levels, UCLA activity level, WOMAC score, patient demographics as well as surgical, implant, and radiographic data were collected. Bivariate correlations and multivariate log-linear regression models were used to compare the presence of pseudotumor and elevated metal ions with all other factors. RESULTS Ultrasound detected a solid, cystic, or mixed mass in 20% hips (38 of 191). No correlation was found between the presence of pseudotumor and any risk factor that we examined. After controlling for confounding variables, elevated cobalt ions were correlated (p<0.001, R=0.50, R2=0.25) with smaller femoral head size, the presence of bilateral MoM THA, and female sex. Elevated chromium ions were correlated (p<0.001, R=0.59, R2=0.34) with smaller femoral head size, presence of bilateral MoM THA, and lower body mass index. The overall survival of MoM THA was 96% at a mean followup of 4.5 years (range, 2-8 years). CONCLUSIONS With the numbers available, we found no associations between the presence of pseudotumor and the potential risk factors we analyzed, including elevated metal ion levels. Further work is needed to explain why larger femoral head sizes resulted in lower metal ion levels despite being associated with higher early failure rates in joint registry data. LEVEL OF EVIDENCE Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
16
|
A case series of 35 hip revisions for adverse reactions to metal debris following Cormet hip resurfacing. Hip Int 2014; 24:575-81. [PMID: 25096457 DOI: 10.5301/hipint.5000161] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/09/2014] [Indexed: 02/04/2023]
Abstract
The primary aim of this study was to analyse our painful metal-on-metal (MoM) hip resurfacing revisions with evidence of 'adverse reactions to metal debris' (ARMD). In our series of 35 revisions the median whole blood Cobalt levels were 58 nmols/l (range 12-1407 nmols/l), and whole blood Chromium levels were 73 nmols/l (range 2-353 nmols/l). Thirty-four of our 35 patients had abnormal imaging on Ultrasound scanning (USS). The mean histological Campbell grading of ARMD was 4, and ranged from 0-9. The mean Oxford Hip Score (OHS) increased from 19 pre-revision (range 4-46) to 33 post-revision surgery (range 23-47).We found no correlation between the preoperative metal ion levels, and the severity of the disease or the outcome.Pain following hip resurfacing may arise from a number of causes and when groin pain arises in conjunction with abnormal cross sectional imaging we have offered our patients revision surgery regardless of raised metal ions or grossly abnormal imaging, with good results.
Collapse
|
17
|
Reito A, Elo P, Puolakka T, Pajamäki J, Nieminen J, Eskelinen A. Repeated magnetic resonance imaging in 154 hips with large-diameter metal-on-metal hip replacement. Acta Orthop 2014; 85:570-6. [PMID: 25238435 PMCID: PMC4259038 DOI: 10.3109/17453674.2014.961868] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Accepted: 06/02/2014] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE The US Food and Drug Administration and the UK Medicines and Health Regulation Agency recommend using MRI in the evaluation of patients with large-diameter metal-on-metal (LD-MoM) hips. Such recommendations do not take into account the relevance of repeated cross-sectional imaging. We therefore investigated the natural course of pseudotumors in patients with LD-MoM hip replacements. PATIENTS AND METHODS Of 888 ASR patients (1,036 hips) 674 patients (798 hips) underwent 2 follow-up visits at our institution. Of these, we identified 124 patients (154 hips) who had undergone repeated clinical assessment including MRI and whole-blood metal ion assessment. RESULTS A change in classification in imaging findings between the 2 MRIs was seen in 17 of the 154 hips (11%). In 13 hips (8%), a significant progression of the pseudotumor was evident, while in 4 (3 %) there was a retrogressive change. 10 of these 13 hips had had a normal first MRI. Patients with a progressive change in the scans did not differ significantly from those without a change in MRI classification regarding follow-up time, time interval between MRIs, or changes in whole-blood Cr and Co levels between assessments. INTERPRETATION A change in classification was rare, considering that all patients had a clinical indication for repeated imaging. Progression of the findings did not appear to correlate clearly with symptoms or whole-blood metal values.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement , Tampere , Finland
| | | | | | | | | | | |
Collapse
|
18
|
Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N. Is ultrasound screening reliable for adverse local tissue reaction after hip arthroplasty? J Arthroplasty 2014; 29:2239-44. [PMID: 24908625 DOI: 10.1016/j.arth.2014.04.030] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 03/27/2014] [Accepted: 04/22/2014] [Indexed: 02/01/2023] Open
Abstract
There is increasing awareness of prevalence of adverse local tissue reaction (ALTR) surrounding metal-on-metal (MoM) and highly cross-linked polyethylene (HXLPE) bearings, and sensitive and simple screening modalities for ALTR are required. We examined reliability of ultrasound screening for ALTR in 131 hips of 105 patients who received both ultrasound and MRI examinations after hip arthroplasty with MoM or HXLPE bearings. Using the MRI results as reference, sensitivity, specificity and accuracy of ultrasound were 74%, 92% and 84% around MoM bearings, and 90%, 83%, and 85% around HXLPE bearings. Ultrasound detected ALTR in 11 hips that were not shown with MRI. Ultrasound examination is assumed to be a reliable screening tool for detecting clinically important ALTR lesions developing in the anterior region around MoM or HXLPE bearings.
Collapse
Affiliation(s)
- Takashi Nishii
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Masaki Takao
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Hideki Yoshikawa
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
19
|
Abstract
OBJECTIVE The purpose of this article is to explain the basic physics of imaging patients with metal implants, explain conflicting information regarding MRI scanning of "MR Conditional" devices, and relate our experience of scanning total joint arthroplasty (TJA) at our institution. CONCLUSION MRI near TJA is effective with appropriate imaging protocols and standardized safety precautions. Strict adherence to MR Conditional labeling may preclude broad use of MRI for TJA assessment.
Collapse
|
20
|
Siddiqui IA, Sabah SA, Satchithananda K, Lim AK, Cro S, Henckel J, Skinner JA, Hart AJ. A comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty. Acta Orthop 2014; 85:375-82. [PMID: 24694273 PMCID: PMC4105768 DOI: 10.3109/17453674.2014.908345] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Metal artifact reduction sequence (MARS) MRI and ultrasound scanning (USS) can both be used to detect pseudotumors, abductor muscle atrophy, and tendinous pathology in patients with painful metal-on-metal (MOM) hip arthroplasty. We wanted to determine the diagnostic test characteristics of USS using MARS MRI as a reference for detection of pseudotumors and muscle atrophy. PatienTS AND METHODS: We performed a prospective cohort study to compare MARS MRI and USS findings in 19 consecutive patients with unilateral MOM hips. Protocolized USS was performed by consultant musculoskeletal radiologists who were blinded regarding clinical details. Reports were independently compared with MARS MRI, the imaging gold standard, to calculate predictive values. RESULTS The prevalence of pseudotumors on MARS MRI was 68% (95% CI: 43-87) and on USS it was 53% (CI: 29-76). The sensitivity of USS in detecting pseudotumors was 69% (CI 39-91) and the specificity was 83% (CI: 36-97). The sensitivity of detection of abductor muscle atrophy was 47% (CI: 24-71). In addition, joint effusion was detected in 10 cases by USS and none were seen by MARS MRI. INTERPRETATION We found a poor agreement between USS and MARS MRI. USS was inferior to MARS MRI for detection of pseudotumors and muscle atrophy, but it was superior for detection of joint effusion and tendinous pathologies. MARS MRI is more advantageous than USS for practical reasons, including preoperative planning and longitudinal comparison.
Collapse
Affiliation(s)
- Imran A Siddiqui
- Institute of Orthopedic and Musculoskeletal Science, University College London, the Royal National Orthopedic Hospital, Brockley Hill, Stanmore
| | - Shiraz A Sabah
- Institute of Orthopedic and Musculoskeletal Science, University College London, the Royal National Orthopedic Hospital, Brockley Hill, Stanmore
| | | | - Adrian K Lim
- Department of Radiology, Imperial College Healthcare NHS Trust, London
| | - Suzie Cro
- MRC Clinical Trials Unit, London, UK
| | - Johann Henckel
- Institute of Orthopedic and Musculoskeletal Science, University College London, the Royal National Orthopedic Hospital, Brockley Hill, Stanmore
| | - John A Skinner
- Institute of Orthopedic and Musculoskeletal Science, University College London, the Royal National Orthopedic Hospital, Brockley Hill, Stanmore
| | - Alister J Hart
- Institute of Orthopedic and Musculoskeletal Science, University College London, the Royal National Orthopedic Hospital, Brockley Hill, Stanmore
| |
Collapse
|
21
|
Kwon YM. Cross-sectional imaging in evaluation of soft tissue reactions secondary to metal debris. J Arthroplasty 2014; 29:653-6. [PMID: 24655608 DOI: 10.1016/j.arth.2014.02.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Accepted: 02/03/2014] [Indexed: 02/01/2023] Open
Abstract
An integral component of systematic treatment algorithms to optimize evaluation and management of patients with MoM hip arthroplasty recommend the use of cross-sectional imaging to diagnose the presence of adverse local tissue reactions. Cross-sectional imaging studies such as ultrasound is a useful screening tool to detect the presence of a soft-tissue mass adjacent to a MoM implant. MARS MRI is a useful diagnostic test for assessing MoM hip arthroplasty and modular taper corrosion for adverse tissue reactions. Each cross-sectional imaging modality has unique utility and limitations. As metal artifact reduction technique continues to be refined, the utility of MARS MRI in evaluating patients with MoM hip arthroplasty and modular taper corrosion is likely to have an increased role in the clinical decision making process. However, over-reliance on any single investigative tool in the clinical decision-making process should be avoided.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery Massachusetts General Hospital Harvard Medical School Boston, Massachusetts
| |
Collapse
|
22
|
van der Weegen W, Brakel K, Horn RJ, Hoekstra HJ, Sijbesma T, Pilot P, Nelissen RGHH. Asymptomatic pseudotumours after metal-on-metal hip resurfacing show little change within one year. Bone Joint J 2014; 95-B:1626-31. [PMID: 24293591 DOI: 10.1302/0301-620x.95b12.32248] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The aim of this study was to establish the natural course of unrevised asymptomatic pseudotumours after metal-on-metal (MoM) hip resurfacing during a six- to 12-month follow-up period. We used repeated metal artefact reduction sequence (MARS)-magnetic resonance imaging (MRI), serum metal ion analysis and clinical examination to study 14 unrevised hips (mean patient age 52.7 years, 46 to 68, 5 female, 7 male) with a pseudotumour and 23 hips (mean patient age 52.8 years, 38 to 69, 7 female, 16 male) without a pseudotumour. The mean post-operative time to the first MARS-MRI scan was 4.3 years (2.2 to 8.3), and mean time between the first and second MARS-MRI scan was eight months (6 to 12). At the second MRI scan, the grade of severity of the pseudotumour had not changed in 35 hips. One new pseudotumour (Anderson C2 score, moderate) was observed, and one pseudotumour was downgraded from C2 (moderate) to C1 (mild). In general, the characteristics of the pseudotumours hardly changed. Repeated MARS-MRI scans within one year in patients with asymptomatic pseudotumours after MoM hip resurfacing showed little or no variation. In 23 patients without pseudotumour, one new asymptomatic pseudotumour was detected. This is the first longitudinal study on the natural history of pseudotumours using MARS-MRI scans in hip resurfacing, and mirrors recent results for 28 mm diameter MoM total hip replacement.
Collapse
Affiliation(s)
- W van der Weegen
- St. Anna Hospital, Department of Orthopaedic Surgery, Bogardeind 2, 5664 EH Geldrop, the Netherlands
| | | | | | | | | | | | | |
Collapse
|
23
|
The John Charnley Award: Diagnostic accuracy of MRI versus ultrasound for detecting pseudotumors in asymptomatic metal-on-metal THA. Clin Orthop Relat Res 2014; 472:417-23. [PMID: 23868425 PMCID: PMC3890209 DOI: 10.1007/s11999-013-3181-6] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The prevalence of pseudotumors in patients with large-head metal-on-metal (MOM) THA has been the subject of implant recalls and warnings from various regulatory agencies. To date, there is no consensus on whether ultrasound or MRI is superior for the detection of pseudotumors. QUESTIONS/PURPOSES We prospectively compared ultrasound to MRI for pseudotumor detection in an asymptomatic cohort of patients with MOM THAs. We also compared ultrasound to MRI for assessment of pseudotumor growth and progressive soft tissue involvement at a 6-month interval. METHODS We enrolled 40 patients with large-head MOM THAs in the study. The mean age was 54 years (range, 34-76 years). The mean time from surgery was 54 months (range, 40-81 months). There were 28 men and 12 women. All patients underwent ultrasound and MRI using slice encoding for metal artifact correction. The gold standard was defined as follows: if both ultrasound and MRI agreed, this was interpreted as concordant and the result was considered accurate. RESULTS Ultrasound and MRI agreed in 37 of 40 patients (93%). The prevalence of pseudotumors was 31% (12 of 39) in our cohort. Twenty-three of 39 patients (59%) had completely normal tests and four (10%) had simple fluid collections. Ultrasound had a sensitivity of 100% and specificity of 96% while MRI had a sensitivity of 92% and specificity of 100%. CONCLUSIONS A negative ultrasound rules out pseudotumor in asymptomatic patients as this test is 100% sensitive. Given its lower cost, we recommend ultrasound as the initial screening tool for pseudotumors.
Collapse
|
24
|
Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME. Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am 2014; 96:e4. [PMID: 24382732 DOI: 10.2106/jbjs.m.00160] [Citation(s) in RCA: 120] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
There should be a low threshold to perform a systematic evaluation of patients with MoM hip arthroplasty as early recognition and diagnosis will facilitate the initiation of appropriate treatment prior to significant adverse biological reactions. A painful MoM hip arthroplasty has various intrinsic and extrinsic causes, and a systematic treatment approach based on the currently available data is presented to optimize management of MoM patients. The risk stratification algorithm presented will continue to develop as further evidence becomes available providing additional insights. While specialized tests such as metal ion analysis are useful modalities for assessing MoM hip arthroplasty, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. Future research focusing on validation of the current diagnostic tools for detecting adverse local tissue reactions as well as optimization of MoM bearings and modular connections to further diminish wear and corrosion is warranted.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114
| | - Adolph V Lombardi
- Joint Implant Surgeons, Inc., The Ohio State University, 7277 Smith's Mill Road, Suite 200, New Albany, OH 43054
| | - Joshua J Jacobs
- Department of Orthopaedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| | - Thomas K Fehring
- Ortho Carolina Hip and Knee Center, 2001 Vail Avenue, #200a, Charlotte, NC 28207
| | - Courtland G Lewis
- Orthopedic Associates of Hartford, 85 Seymour Street, Hartford, CT 06106
| | - Miguel E Cabanela
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905
| |
Collapse
|
25
|
Tam H, Bhaludin B, Rahman F, Weller A, Ejindu V, Parthipun A. SPECT-CT in total hip arthroplasty. Clin Radiol 2014; 69:82-95. [DOI: 10.1016/j.crad.2013.08.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2013] [Revised: 07/23/2013] [Accepted: 08/05/2013] [Indexed: 10/26/2022]
|
26
|
Abstract
BACKGROUND Adverse reaction to metal debris is a relatively recently described and often a silent complication of metal-on-metal (MOM) total hip replacements (THR). The Norfolk & Norwich University Hospital has been performing metal artefact reduction (MARS) MRI for 8 years in a variety of different types of MOM THR. QUESTIONS/PURPOSES The aims of this review are to describe the experience of using MARS MRI in Norwich and to compare our experience with that published by other groups. METHODS A MEDLINE keyword search was performed for studies including MRI in MOM THR. Relevant publications were reviewed and compared with published data from the Norfolk & Norwich University Hospital. The similarities and differences between these data were compared and possible explanations for these discussed. RESULTS MARS MRI appears to be the most useful tool for diagnosing, staging and monitoring adverse reactions to metal debris (ARMD). There appears to be no clinically useful association between clinical and serological markers of disease and the severity of MR findings. Although severe early ARMD is associated with significant morbidity, mild disease is often stable for years. If patients with normal initial MR examinations develop ARMD, this usually occurs 7 years. A 1-year interval between MRI examinations is reasonable in asymptomatic patients. CONCLUSIONS There is a general international consensus that ARMD is prevalent in symptomatic and asymptomatic patients with MOM THR and that while appearances vary with the type of prosthesis, there are characteristic features that make MARS MRI essential for diagnosis, staging and surveillance of the disease.
Collapse
|
27
|
Siddiqui I, Sabah S, Satchithananda K, Lim A, Henckel J, Skinner J, Hart A. Cross-sectional imaging of the metal-on-metal hip prosthesis: The London ultrasound protocol. Clin Radiol 2013; 68:e472-8. [DOI: 10.1016/j.crad.2013.02.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2012] [Revised: 01/29/2013] [Accepted: 02/07/2013] [Indexed: 11/26/2022]
|
28
|
Mittal S, Revell M, Barone F, Hardie DL, Matharu GS, Davenport AJ, Martin RA, Grant M, Mosselmans F, Pynsent P, Sumathi VP, Addison O, Revell PA, Buckley CD. Lymphoid aggregates that resemble tertiary lymphoid organs define a specific pathological subset in metal-on-metal hip replacements. PLoS One 2013; 8:e63470. [PMID: 23723985 PMCID: PMC3665779 DOI: 10.1371/journal.pone.0063470] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Accepted: 04/02/2013] [Indexed: 12/12/2022] Open
Abstract
Aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) has been used to describe the histological lesion associated with metal-on-metal (M-M) bearings. We tested the hypothesis that the lymphoid aggregates, associated with ALVAL lesions resemble tertiary lymphoid organs (TLOs). Histopathological changes were examined in the periprosthetic tissue of 62 M-M hip replacements requiring revision surgery, with particular emphasis on the characteristics and pattern of the lymphocytic infiltrate. Immunofluorescence and immunohistochemistry were used to study the classical features of TLOs in cases where large organized lymphoid follicles were present. Synchrotron X-ray fluorescence (XRF) measurements were undertaken to detect localisation of implant derived ions/particles within the samples. Based on type of lymphocytic infiltrates, three different categories were recognised; diffuse aggregates (51%), T cell aggregates (20%), and organised lymphoid aggregates (29%). Further investigation of tissues with organised lymphoid aggregates showed that these tissues recapitulate many of the features of TLOs with T cells and B cells organised into discrete areas, the presence of follicular dendritic cells, acquisition of high endothelial venule like phenotype by blood vessels, expression of lymphoid chemokines and the presence of plasma cells. Co-localisation of implant-derived metals with lymphoid aggregates was observed. These findings suggest that in addition to the well described general foreign body reaction mediated by macrophages and a T cell mediated type IV hypersensitivity response, an under-recognized immunological reaction to metal wear debris involving B cells and the formation of tertiary lymphoid organs occurs in a distinct subset of patients with M-M implants.
Collapse
Affiliation(s)
- Saloni Mittal
- Rheumatology Research Group, Institute of Biomedical Research, MRC Centre for Immune Regulation, University of Birmingham, Birmingham, United Kingdom
- Royal Orthopedic Hospital, Birmingham, United Kingdom
| | | | - Francesca Barone
- Rheumatology Research Group, Institute of Biomedical Research, MRC Centre for Immune Regulation, University of Birmingham, Birmingham, United Kingdom
| | - Debbie L. Hardie
- Rheumatology Research Group, Institute of Biomedical Research, MRC Centre for Immune Regulation, University of Birmingham, Birmingham, United Kingdom
| | | | - Alison J. Davenport
- School of Metallurgy and Materials, University of Birmingham, Birmingham, United Kingdom
| | - Richard A. Martin
- School of Engineering and Applied Sciences & Aston Research Centre for Healthy Ageing, University of Aston, Birmingham, United Kingdom
| | - Melissa Grant
- Biomaterials Unit, School of Dentistry, University of Birmingham, Birmingham, United Kingdom
| | | | - Paul Pynsent
- Royal Orthopedic Hospital, Birmingham, United Kingdom
| | | | - Owen Addison
- Biomaterials Unit, School of Dentistry, University of Birmingham, Birmingham, United Kingdom
| | | | - Christopher D. Buckley
- Rheumatology Research Group, Institute of Biomedical Research, MRC Centre for Immune Regulation, University of Birmingham, Birmingham, United Kingdom
| |
Collapse
|
29
|
Macnair RD, Wynn-Jones H, Wimhurst JA, Toms A, Cahir J. Metal ion levels not sufficient as a screening measure for adverse reactions in metal-on-metal hip arthroplasties. J Arthroplasty 2013; 28:78-83. [PMID: 22771092 DOI: 10.1016/j.arth.2012.05.029] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 04/02/2012] [Accepted: 05/15/2012] [Indexed: 02/01/2023] Open
Abstract
This study aims to assess the accuracy of metal ion analysis in the diagnosis of adverse reaction to metal debris (ARMD) in patients with metal-on-metal hip arthroplasties by comparing the cobalt and chromium levels in 57 patients (62 hips) to findings on metal artifact reduction magnetic resonance imaging (MRI). An ARMD was detected using MRI in 18 (29%) of the hips. Forty patients had cobalt levels less than 7 μg/L, and 33 had chromium levels less than 7 μg/L, but 8 of these had an ARMD on MRI and only minimal symptoms (Oxford Hip Score ≥ 44/48). The incidence of ARMD was significantly higher when chromium concentration was above 7 μg/L (P = .02), but normal metal ion levels can be misleading and metal artifact reduction MRI imaging is advised in all patients.
Collapse
Affiliation(s)
- Rory D Macnair
- Department of Orthopaedic Surgery, Royal Cornwall Hospital, Truro, Cornwall, UK
| | | | | | | | | |
Collapse
|
30
|
Abstract
OBJECTIVE The objective of our study was to compare the frequency of osseous and soft-tissue abnormalities in patients presenting with hip pain after resurfacing arthroplasty and after total hip arthroplasty (THA), correlate the MRI findings with histologic results, and determine which MRI findings are predictive of aseptic lymphocytic vasculitis-associated lesions. MATERIALS AND METHODS The MRI examinations of patients with metal-on-metal hip prostheses placed at resurfacing arthroplasty (n=31) or THA (n=29) were reviewed for osteolysis, synovitis, extracapsular disease, synovial pattern, and mode of decompression into adjacent bursae. Regional muscles and tendons were assessed for tendinosis, tear, atrophy, and edema. Histologic and operative findings were reviewed in 19 patients (20 hips) who underwent revision surgery. Chi-square tests were performed to detect differences between the resurfacing arthroplasty and THA groups. The Wilcoxon rank sum test was performed to detect differences in MRI findings in patients with and those without aseptic lymphocytic vasculitis-associated lesions. RESULTS Synovitis was detected in 77.4% of resurfacing arthroplasty hips and 86.2% of THA hips. Extracapsular disease was present in 6.5% of resurfacing arthroplasty hips and 10.3% of THA hips. Osteolysis was detected in 9.7% of resurfacing arthroplasty hips and 24.1% of THA hips. There was no difference in the incidence of synovitis (p=0.51), osteolysis (p=0.17), or extracapsular disease (p=0.67) between the resurfacing arthroplasty and THA groups. Patients with aseptic lymphocytic vasculitis-associated lesions had higher volumes of synovitis (p=0.04) than patients without aseptic lymphocytic vasculitis-associated lesions. Extracapsular disease and muscle edema were seen only in patients with aseptic lymphocytic vasculitis-associated lesions. CONCLUSION Synovitis is common in patients with metal-on-metal hip prostheses and occurs with a similar incidence after resurfacing arthroplasty and after THA; osteolysis and extracapsular disease are uncommon. The MRI signs most suggestive of aseptic lymphocytic vasculitis-associated lesions are high volumes of synovitis, extracapsular disease, and intramuscular edema.
Collapse
|
31
|
Patel AR, Patel RM, Thomas D, Bauer TW, Stulberg SD. Caveat Emptor: Adverse Inflammatory Soft-Tissue Reactions in Total Hip Arthroplasty with Modular Femoral Neck Implants: A Report of Two Cases. JBJS Case Connect 2012; 2:e80. [PMID: 29252376 DOI: 10.2106/jbjs.cc.l.00136] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Anay R Patel
- 676 North Saint Clair Street, Suite 1350, Chicago, IL 60611.
| | - Ronak M Patel
- 676 North Saint Clair Street, Suite 1350, Chicago, IL 60611.
| | | | - Thomas W Bauer
- Cleveland Clinic Main Campus, Mail Code L25, 9500 Euclid Avenue, Cleveland, OH 44195
| | - S David Stulberg
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, 680 North Lake Shore Drive, Suite 924, Chicago, IL 60611-3057
| |
Collapse
|
32
|
Kwon YM, Jacobs JJ, MacDonald SJ, Potter HG, Fehring TK, Lombardi AV. Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients. J Arthroplasty 2012; 27:20-5. [PMID: 22608691 DOI: 10.1016/j.arth.2012.03.029] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2012] [Accepted: 03/13/2012] [Indexed: 02/01/2023] Open
Abstract
Adverse biological reactions causing failures of metal-on-metal (MoM) hip arthroplasty can be local or systemic. Both dose-dependent cytotoxicity of wear debris leading to subsequent necrosis of periprosthetic soft tissues and adaptive immunity may play an important role in pathogenesis in susceptible patients. There appears to be a spectrum of clinical presentations of adverse soft tissue reactions, reflecting a complex interplay of implant, surgical, and patient factors. A systematic treatment approach is helpful in optimizing evidence-based management of MoM patients. Although specialized tests such as metal ion levels are a useful diagnostic tool for evaluating MoM hip arthroplasty patients, overreliance on any single investigative tool in clinical decision-making process should be avoided. Future research focusing on diagnostic tools for detecting adverse periprosthetic soft tissue necrosis as well as optimization of MoM bearings and modular connections to further diminish wear and corrosion is warranted.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, USA
| | | | | | | | | | | |
Collapse
|
33
|
Douis H, Dunlop DJ, Pearson AM, O'Hara JN, James SLJ. The role of ultrasound in the assessment of post-operative complications following hip arthroplasty. Skeletal Radiol 2012; 41:1035-46. [PMID: 22426776 DOI: 10.1007/s00256-012-1390-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2011] [Revised: 01/09/2012] [Accepted: 02/26/2012] [Indexed: 02/02/2023]
Abstract
Hip arthroplasty is one of the most commonly performed orthopedic procedures. Clinicians can be faced with the diagnostic dilemma of the patient presenting with a painful hip following arthroplasty and satisfactory post-operative radiographs. Identifying the cause of symptoms can be challenging and ultrasound is increasingly being utilized in the evaluation of potential soft tissue complications following hip surgery. In this article, we describe the common surgical approaches used during hip arthroplasty as this can influence the nature and location of subsequent complications. A review of the literature is presented along with the imaging appearances frequently encountered when imaging this patient population.
Collapse
Affiliation(s)
- H Douis
- Department of Radiology, The Royal Orthopaedic Hospital NHS Foundation Trust, Bristol Road South, Northfield, Birmingham, B31 2AP, UK
| | | | | | | | | |
Collapse
|
34
|
Metal-on-metal bearings, inflammatory pseudotumours and their neurological manifestations. Hip Int 2012; 22:129-36. [PMID: 22476931 DOI: 10.5301/hip.2012.9185] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/17/2012] [Indexed: 02/04/2023]
Abstract
Metal-on-metal bearings have become more popular for hip arthroplasty in younger patients in the last 15 years. We present a review of the neurological consequences relating to such bearing surfaces illustrated by an appropriate case report. The mechanisms of increased metal ion production and pseudotumour formation are discussed. If unexplained neurology, hip/groin pain or a localised mass around the hip are present with a metal bearing hip then urgent referral to a specialist orthopaedic surgeon is warranted for consideration of exchange arthroplasty.
Collapse
|
35
|
Stürup J, Dahl LB, Jensen KE, Larsen AB, Gebuhr P. Few adverse reactions to metal on metal articulation in total hip arthroplasty in a review study on 358 consecutive cases with 1 to 5 years follow-up. Open Orthop J 2012; 6:366-70. [PMID: 22930667 PMCID: PMC3428671 DOI: 10.2174/1874325001206010366] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Revised: 07/17/2012] [Accepted: 07/22/2012] [Indexed: 12/12/2022] Open
Abstract
The aim of the present study was to determine the frequency of adverse reaction to metal on metal total hip arthroplasty using a M2a-38 articulation and a Magnum articulation, (Biomet Warsaw, Indiana).All patients who had received a Metal on Metal bearing prosthesis, in two centres in Copenhagen, were asked to complete a questionnaire about groin pain. Patients with self-reported groin pain, 68/314, underwent a physical examination and had Co and Cr ion levels measured in full blood samples. Fifty patients also had a CT scan performed.The present study found one patient with bilateral arthroplasty, who had an adverse reaction on one side. In addition the study showed that females had higher values of Co and Cr, and that younger patient reported groin pain more often.The conclusion of this study is that the number of adverse reactions is low, despite the time of observation being relatively short, no high frequency of adverse reactions to this prosthesis is expected.
Collapse
Affiliation(s)
- Jens Stürup
- Orthopaedic Department U, 2162, Rigshospitalet, University of Copenhagen, Denmark
| | | | | | | | | |
Collapse
|
36
|
MRI of aseptic lymphocytic vasculitis-associated lesions in metal-on-metal hip replacements. AJR Am J Roentgenol 2012; 198:1394-402. [PMID: 22623554 DOI: 10.2214/ajr.11.7504] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The aim of this review is to describe the clinical, histopathologic, and MRI features of aseptic lymphocytic vasculitis-associated lesions in total hip replacements. CONCLUSION The introduction of modern metal-on-metal hip arthroplasty has been accompanied by a newly described disease, aseptic lymphocytic vasculitis-associated lesions, which is characterized histologically by bland necrosis and dense perivascular lymphocytic infiltrates. Conventional radiographic findings are often normal, but the typical MRI findings include periprosthetic fluid collections, soft-tissue masses, gluteal tendon avulsion, bone loss, periosteal stripping, neurovascular involvement, and periprosthetic fractures. The severity of the histologic and MRI appearances can be graded according to defined published criteria.
Collapse
|
37
|
Thomas MS, O'Hara JN, Davies AM, James SLJ. Profunda femoris pseudoaneurysm following Birmingham hip resurfacing: an important differential diagnosis for a periarticular cystic mass. Skeletal Radiol 2012; 41:853-6. [PMID: 22197889 DOI: 10.1007/s00256-011-1341-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Revised: 11/23/2011] [Accepted: 11/28/2011] [Indexed: 02/02/2023]
Abstract
Vascular injury following hip resurfacing arthroplasty is rare: we present a case of profunda femoris pseudoaneurysm complicating hip resurfacing arthroplasty performed via an anterolateral approach. Over recent years, it has been recognized that an adverse reaction to metal debris from metal-on-metal arthroplasties can also result in the development of cystic masses around the hip. This case highlights a potential rare differential diagnosis that needs to be considered when imaging cystic mass lesions around the postoperative hip. Imaging can provide a definitive diagnosis if this entity is considered and its appearances recognized, resulting in appropriate management of this potentially limb- and life-threatening complication.
Collapse
Affiliation(s)
- M S Thomas
- Department of Radiology, The Royal Orthopaedic Hospital NHS Foundation Trust, Bristol Road South, Northfield, Birmingham, B31 2AP, UK.
| | | | | | | |
Collapse
|
38
|
Roth TD, Maertz NA, Parr JA, Buckwalter KA, Choplin RH. CT of the Hip Prosthesis: Appearance of Components, Fixation, and Complications. Radiographics 2012; 32:1089-107. [DOI: 10.1148/rg.324115183] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
39
|
Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings. J Arthroplasty 2012; 27:895-900. [PMID: 22047978 DOI: 10.1016/j.arth.2011.09.015] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Accepted: 09/16/2011] [Indexed: 02/01/2023] Open
Abstract
Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities.
Collapse
Affiliation(s)
- Takashi Nishii
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, Japan
| | | | | | | | | |
Collapse
|
40
|
Kwon YM, Mellon SJ, Monk P, Murray DW, Gill HS. In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours. Bone Joint Res 2012; 1:42-9. [PMID: 23610670 PMCID: PMC3626206 DOI: 10.1302/2046-3758.14.2000019] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 03/20/2012] [Indexed: 12/12/2022] Open
Abstract
Objectives Pseudotumours (abnormal peri-prosthetic soft-tissue reactions)
following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have
been associated with elevated metal ion levels, suggesting that
excessive wear may occur due to edge-loading of these MoM implants.
This study aimed to quantify in vivo edge-loading
in MoMHRA patients with and without pseudotumours during functional
activities. Methods The duration and magnitude of edge-loading in vivo was
quantified during functional activities by combining the dynamic
hip joint segment contact force calculated from the three-dimensional
(3D) motion analysis system with the 3D reconstruction of orientation
of the acetabular component and each patient’s specific hip joint
centre, based on CT scans. Results Edge-loading in the hips with pseudotumours occurred with a four-fold
increase in duration and magnitude of force compared with the hips
without pseudotumours (p = 0.02). Conclusions The study provides the first in vivo evidence to support that
edge-loading is an important mechanism that leads to localised excessive
wear (edge-wear), with subsequent elevation of metal ion levels
in MoMHRA patients with pseudotumours.
Collapse
Affiliation(s)
- Y-M Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Suite 3B, Boston, Massachusetts 02114, USA
| | | | | | | | | |
Collapse
|
41
|
Harvie P, Torres-Grau J, Beaver RJ. Common peroneal nerve palsy associated with pseudotumour after total knee arthroplasty. Knee 2012; 19:148-50. [PMID: 21497506 DOI: 10.1016/j.knee.2011.02.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2010] [Revised: 01/16/2011] [Accepted: 02/04/2011] [Indexed: 02/02/2023]
Abstract
Pseudotumours about the hip as a result of metal-on-metal wear debris are now widely reported. Nerve palsies associated with such lesions are less commonly described. To our knowledge no previous reports exist which describe pseudotumours about a total knee arthroplasty. The case of a metal-on-metal debris-induced pseudotumour about a total knee arthroplasty with an associated common peroneal nerve palsy is presented. The use of serum ion levels is discussed, specifically for the early detection and diagnosis of full-thickness polyethylene liner wear and subsequent revision options.
Collapse
Affiliation(s)
- Paul Harvie
- The Department Of Elective Orthopaedics, Royal Perth Hospital, Shenton Park, Western Australia 6008.
| | | | | |
Collapse
|
42
|
Abstract
We compared 47 patients with groin pain following hip resurfacing to a matched control group. Functional scores and plain radiographs were assessed along with measurement of whole blood cobalt and chromium by inductively coupled mass spectrometry. Symptomatic patients underwent ultrasound scan of the affected hip. Mean functional outcomes were poor in those with pain and good in the control group. Groin pain was associated with valgus stem positioning and lower neck:head ratio (relatively narrow neck) (p=0.03, p=0.04 respectively). We classified patients with groin pain into two groups: biological and mechanical. The biological group had soft tissue abnormalities on USS and higher levels of cobalt and chromium (p=0.04, p=0.05 respectively). The mechanical group had normal USS, lower metal ion levels and more retroverted femoral components (p=0.01).
Collapse
|
43
|
von Domarus C, Rosenberg JP, Rüther W, Zustin J. Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties. Acta Orthop 2011; 82:596-601. [PMID: 22112191 PMCID: PMC3242957 DOI: 10.3109/17453674.2011.625534] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that both findings are unspecific for metal-on-metal bearing coupes. Thus, we wished to quantify the extent of necrobiosis and the amount of T-lymphocyte infiltration in aseptically loosened metal-on-polyethylene prostheses. MATERIALS AND METHODS We analyzed 28 consecutive synovial biopsy specimens obtained at revision surgery of aseptically loosened metal-on-polyethylene prostheses (19 hips and 9 knees) and quantified both the extent of necrobiosis vertically and the density of CD3+, CD4+, and CD8+ lymphocytes within the joint capsular tissue. We excluded patients with inflammatory skeletal disease or with a history of metal hypersensitivity. RESULTS We found necrobiosis in 23 of 28 cases and it was most often connected with the superficial portions of the synovium. Necrobiosis of deeper tissues was seen in 8 specimens and it was strongly associated with superficial necrobiosis. While CD3+ lymphocytes were detected in each biopsy, 4 cases with more than 300 CD3+ lymphocytes were identified in the group of 26 cases that presented with more than 100 CD3+ lymphocytes within one high-power field. 16 cases with more than 100 CD3+ lymphocytes also showed concomitant superficial necrobiosis of the synovium. In the inflammatory infiltration of periprosthetic synovium, CD8+ lymphocytes predominated over CD4+ cells. INTERPRETATION Synovial necrobiosis and infiltration of T-lymphocytes are common findings in tissues around aseptically loosened metal-on-polyethylene arthroplasty in patients without a clinically suspected metal hypersensitivity reaction. Thus, neither necrobiosis nor infiltration of T-lymphocytes should be considered to be specific for failed metal-on-metal bearings or metal hypersensitivity reaction.
Collapse
Affiliation(s)
| | - Jens P Rosenberg
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Jozef Zustin
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
44
|
Cousen PJ, Gawkrodger DJ. Metal allergy and second-generation metal-on-metal arthroplasties. Contact Dermatitis 2011; 66:55-62. [DOI: 10.1111/j.1600-0536.2011.01970.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
45
|
Abstract
Hip resurfacing arthroplasty is an increasingly common procedure for osteoarthritis. Conventional radiographs are used routinely for follow-up assessment, however they only provide limited information on the radiological outcome. Various complications have been reported in the scientific literature although not all are fully understood. In an effort to investigate problematic or failing hip resurfacings, various radiological methods have been utilized. These methods can be used to help make a diagnosis and guide management. This paper aims to review and illustrate the radiographic findings in the form of radiography, computerized tomography (CT), magnetic resonance imaging (MRI), and ultrasound of both normal and abnormal findings in hip resurfacing arthroplasty. However, imaging around a metal prosthesis with CT and MRI is particularly challenging and therefore the potential techniques used to overcome this are discussed.
Collapse
|
46
|
Wynn-Jones H, Macnair R, Wimhurst J, Chirodian N, Derbyshire B, Toms A, Cahir J. Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty. Acta Orthop 2011; 82:301-7. [PMID: 21504335 PMCID: PMC3235307 DOI: 10.3109/17453674.2011.579518] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2010] [Accepted: 12/16/2010] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty. METHODS We studied the early clinical results and results of routine metal artifact-reduction MRI screening in a series of 79 large-head metal-on-metal hip arthroplasties (ASR; DePuy, Leeds, UK) in 68 patients. 75 hips were MRI scanned at mean 31 (12-52) months after surgery. RESULTS 27 of 75 hips had MRI-detected metal debris-related abnormalities, of which 5 were mild, 18 moderate, and 4 severe. 8 of these hips have been revised, 6 of which were revised for an adverse reaction to metal debris, diagnosed preoperatively with MRI and confirmed histologically. The mean Oxford hip score (OHS) for the whole cohort was 21. It was mean 23 for patients with no MRI-based evidence of adverse reactions and 19 for those with adverse reactions detected by MRI. 6 of 12 patients with a best possible OHS of 12 had MRI-based evidence of an adverse reaction. INTERPRETATION We have found a high early revision rate with a modern, large-head metal-on-metal hip arthroplasty. MRI-detected adverse rections to metal debris was common and often clinically "silent". We recommend that patients with this implant should be closely followed up and undergo routine metal artifact-reduction MRI screening.
Collapse
Affiliation(s)
- Henry Wynn-Jones
- The Centre for Hip Surgery, Wrightington Hospital, Lancashire, UK.
| | | | | | | | | | | | | |
Collapse
|
47
|
Kwon YM, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW. "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplasty 2011; 26:511-8. [PMID: 20591612 DOI: 10.1016/j.arth.2010.05.030] [Citation(s) in RCA: 261] [Impact Index Per Article: 18.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2009] [Accepted: 05/25/2010] [Indexed: 02/06/2023] Open
Abstract
Symptomatic abnormal periprosthetic soft-tissue reactions ("pseudotumors") have been reported after metal-on-metal hip resurfacing arthroplasty (MoMHRA). The aims of this study were (1) to determine the prevalence of asymptomatic pseudotumors after MoMHRA and (2) to measure metal ion levels in these patients. A total of 201 hips in 158 patients were evaluated at a mean follow-up of 61 months (range, 36-88) using ultrasound/magnetic resonance imaging and serum/hip aspirate cobalt and chromium measurements. Pseudotumors found in 7 patients (4%) were associated with significantly higher cobalt and chromium levels and inferior functional scores. Elevated levels of cobalt and chromium ions suggest that pseudotumors are associated with increased wear generated from metal-on-metal articulations. Clinicians need to be aware of pseudotumors as a differential diagnosis during clinical evaluation of MoMHRA patients, and further imaging such as ultrasound or magnetic resonance imaging is recommended to confirm the diagnosis.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02116, USA
| | | | | | | | | | | |
Collapse
|
48
|
MRI of asymptomatic patients with metal-on-metal and polyethylene-on-metal total hip arthroplasties. Clin Radiol 2011; 66:540-5. [DOI: 10.1016/j.crad.2011.02.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2010] [Revised: 01/31/2011] [Accepted: 02/02/2011] [Indexed: 11/19/2022]
|
49
|
Sabah SA, Mitchell AWM, Henckel J, Sandison A, Skinner JA, Hart AJ. Magnetic resonance imaging findings in painful metal-on-metal hips: a prospective study. J Arthroplasty 2011; 26:71-6, 76.e1-2. [PMID: 20149575 DOI: 10.1016/j.arth.2009.11.008] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2009] [Revised: 07/14/2009] [Accepted: 11/15/2009] [Indexed: 02/01/2023] Open
Abstract
Metal artifact reduction sequence magnetic resonance imaging findings are reported in a prospective series of 31 patients with unexplained painful metal-on-metal (MOM) hips. The abnormalities identified were fluid collection (20 patients), solid mass (2 patients), moderate to severe muscle atrophy (23 patients), and muscle edema (8 patients). In conclusion, soft tissue lesions and muscle atrophy appear to be prevalent in unexplained painful MOM hips. Metal artifact reduction sequence magnetic resonance imaging may be useful to diagnose and monitor at-risk hips but requires validation in well-functioning MOM hips before it can guide clinical decision making.
Collapse
|
50
|
Watters TS, Cardona DM, Menon KS, Vinson EN, Bolognesi MP, Dodd LG. Aseptic lymphocyte-dominated vasculitis-associated lesion: a clinicopathologic review of an underrecognized cause of prosthetic failure. Am J Clin Pathol 2010; 134:886-93. [PMID: 21088151 DOI: 10.1309/ajcpltneuah8xi4w] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
It is estimated that 35% of total hip arthroplasties (THAs) involve a second-generation metal-on-metal (MOM) prosthesis. A novel complication has appeared in a subset of patients with MOM THAs that is described as an aseptic, lymphocyte-dominated vasculitis-associated lesion (ALVAL). The clinical features of ALVAL are nonspecific, but patients complain of pain and may develop "pseudotumors." It is hypothesized that metal ions are released from the prosthesis and form haptens with native proteins that elicit a type IV hypersensitivity response in the local soft tissues. Histopathologic descriptions of ALVAL are similar to those of failed arthroplasty in general, with the addition of a dense perivascular inflammatory infiltrate that is the hallmark of ALVAL. We report 3 cases of ALVAL with clinical, radiographic, and histologic findings. Accurate assessment is crucial because an intraoperative diagnosis of chronic inflammation suggestive of ALVAL will necessitate a replacement of the prosthetic component surfaces.
Collapse
|