1
|
Guo J, Zhang Z. Effects of Predictive Nursing Process on Elderly Patients with Total Hip Arthroplasty. Rejuvenation Res 2025; 28:37-44. [PMID: 39515785 DOI: 10.1089/rej.2024.0059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2024] Open
Abstract
Elderly individuals represent a significant demographic undergoing total hip arthroplasty, with distinct risks and complications. The study aimed to determine whether predictive nursing, guided by risk assessment, could reduce these risks and improve patient outcomes. A total of 191 elderly patients undergoing total hip arthroplasty were included in the study, with 142 patients randomly assigned to either the control or observation groups. The control group received routine care, while the observation group received predictive nursing based on comprehensive risk assessment. Various assessment tools were employed to evaluate risks such as venous thrombosis, pressure injuries, falls, joint dislocation, infections, and psychological factors. The primary outcomes included functional improvement measured by the Harris Hip Score, Activities of Daily Living (ADL), anxiety levels, and patient satisfaction. Our study demonstrated that predictive nursing interventions, guided by comprehensive risk assessment, yielded significant reductions in postoperative complications, particularly deep vein thrombosis, in elderly patients undergoing total hip arthroplasty. In addition, patients who received predictive nursing care experienced notable benefits, including shorter hospital stays, heightened satisfaction levels, enhanced hip function, improved ADL scores, and reduced anxiety levels compared with those receiving standard care. The study underscores the substantial benefits of predictive nursing interventions guided by risk assessment in improving outcomes for elderly patients undergoing total hip arthroplasty, highlighting the potential of individualized nursing care to optimize postoperative recovery and enhance patient well-being.
Collapse
Affiliation(s)
- Jianyu Guo
- Department of Orthopedic Surgery, First Affiliated Hospital of Qiqihar Medical College, Qiqihar, China
| | | |
Collapse
|
2
|
Zhao G, Zhao C, Bao H, Liu J, Zhou B, Wang Y. Role of the Conjoined Tendon in Hip Stability Post-Total Hip Arthroplasty: Insights From a Direct Anterior Approach Cadaver Study. Arthroplast Today 2024; 30:101487. [PMID: 39492994 PMCID: PMC11530807 DOI: 10.1016/j.artd.2024.101487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 06/24/2024] [Accepted: 07/23/2024] [Indexed: 11/05/2024] Open
Abstract
Background Hip dislocation represents a significant complication encountered following hip arthroplasty procedures. In this investigation, we conducted a comparative analysis of the biomechanical characteristics exhibited by the piriformis and the conjoined tendon after total hip arthroplasty (THA) via the direct anterior approach (DAA), utilizing cadaveric specimens. The objective is to ascertain the relative significance of the piriformis muscle and the conjoined tendon in mitigating hip dislocation. Methods A total of 16 hip joints from 8 freshly frozen cadavers were selected and stratified into 2 groups: the piriformis tendon (PT) group and the conjoined tendon (CT) group. Following THA via the DAA, measurements were taken to record the torque required to induce hip dislocation under various conditions. Torque readings were obtained with the tendon in its intact state (intact group) and after preservation or reconstruction of either the PT or the CT. Results The torques of anterior and posterior dislocation in PT group were 22.24 ± 4.53 N.m and 30.7 ± 15.5 N.m following tendon severed, and 20.04 ± 2.67 N.m and 17.5 ± 6.7 N.m following reconstruction. There were no differences compared to the intact group. The torque decreased in the CT group after CT was severed with the torques dropping from 31.2 ± 7.6 N.m to 8.18 ± 2.6 N.m (P < .0001) for anterior dislocation, and from 34.9 ± 8.3 N.m to 9.8 ± 2.8 N.m (P < .0001) for posterior dislocation. Following reconstruction, the torque required for dislocation significantly increased (P < .0001). Conclusions This study underscores the preeminent role of the CT in ensuring hip stability following THA via DAA, highlighting the cruciality of its preservation and reconstruction during surgical interventions.
Collapse
Affiliation(s)
- Gongyin Zhao
- Department of Orthopedics, The Affiliated Changzhou Second People’s Hospital of Nanjing Medical University, Changzhou Medical Center, Nanjing Medical University, Changzhou, China
- Department of Orthopedic Biomechanics Research Laboratory, Mayo Clinic, Rochester, MN, USA
| | | | - Hongwei Bao
- Department of Orthopedics, Jingjiang People's Hospital, Taizhou, China
| | - Junting Liu
- Department of Acute Care Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, China
| | - Baojun Zhou
- Department of Orthopedics, The Third Affiliated Hospital of Gansu University of Chinese Medicine, Baiyin, China
| | - Yuji Wang
- Department of Orthopedics, The Affiliated Changzhou Second People’s Hospital of Nanjing Medical University, Changzhou Medical Center, Nanjing Medical University, Changzhou, China
- Department of Orthopedics, The Third Affiliated Hospital of Gansu University of Chinese Medicine, Baiyin, China
- Department of Orthopedic Surgery and Biochemistry & Molecular Biology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
3
|
Ruspi A, De Leo D, Scandelli F, Tosetto V, Dosella S, Di Mento L, De Donato M, Sconza C, Rosa F, Di Matteo B, Della Rocca F, Azzolini E, Grappiolo G, Schünemann H, Gatti R. Recommendations on the use of restrictions and assistive devices after total hip arthroplasty: an adolopment of guidelines. Disabil Rehabil 2024:1-6. [PMID: 39491358 DOI: 10.1080/09638288.2024.2412185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 09/24/2024] [Accepted: 09/29/2024] [Indexed: 11/05/2024]
Abstract
PURPOSE Movement restrictions and assistive devices have traditionally been recommended to prevent hip dislocation after total hip arthroplasty (THA). Considering the advancements in THA surgery, a review of treatment recommendations is worthwhile. The aim of this study was to investigate whether unrestricted protocol (without movement restrictions and assistive devices) should be recommended for THA patients. METHODS A multiprofessional panel used the GRADE-Adolopment to develop the present recommendations, following the GIN-McMaster-Guideline-Development-Tool. We selected guideline topic and target audience, formulated clinical questions and prioritised outcomes. For the first question, a source guideline was identified and adoloped, whereas the second question required a de-novo recommendation. Therefore, the GRADE-Evidence-Profile and the Evidence-to-Decision framework were completed. Finally, the panel discussed and formulated the final recommendations. RESULTS Hip dislocation was defined as critical outcome. No between-groups differences in the early dislocation rates were found: without movement restrictions, 1623 patients, RR 0.44 (CI95 0.16-1.20); without assistive devices, 4426 patients, RR 0.75 (CI95 0.52-1.08). Finally, considering small desirable health effects and trivial undesirable health effects of the intervention, we integrated two "conditional-recommendations" in favour of an unrestricted protocol. CONCLUSION Through GRADE-adolopment approach new recommendations to provide an evidence-based guidance after THA have been formulated.
Collapse
Affiliation(s)
- Alessandra Ruspi
- Physiotherapy Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Davide De Leo
- Physiotherapy Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Francesco Scandelli
- Physiotherapy Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Valeria Tosetto
- Physiotherapy Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | | | - Lorenzo Di Mento
- Traumatology Department, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Massimo De Donato
- Orthopaedic Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Cristiano Sconza
- Department of Rehabilitation and Functional Recovery, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Francesco Rosa
- Orthopaedic Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Berardo Di Matteo
- Orthopaedic Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Federico Della Rocca
- Orthopaedic Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | | | - Guido Grappiolo
- Orthopaedic Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
| | - Holger Schünemann
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy
- Department of Health Research Methods, Evidence, and Impact, McMaster University, Hamilton, Canada
- Department of Medicine, Hamilton, McMaster University, Hamilton, Canada
- Institute for Evidence in Medicine, Medical Center and Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Roberto Gatti
- Physiotherapy Unit, Humanitas Clinical and Research Center - IRCCS, Rozzano, Italy
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy
| |
Collapse
|
4
|
Za P, Casciaro C, Papalia GF, Parisi FR, Longo UG, Falez F, Papalia R. Hip resurfacing versus total hip arthroplasty: a systematic review and meta-analysis of randomized clinical trials. INTERNATIONAL ORTHOPAEDICS 2024; 48:2589-2601. [PMID: 39107628 DOI: 10.1007/s00264-024-06269-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Accepted: 07/29/2024] [Indexed: 09/25/2024]
Abstract
PURPOSE Total hip arthroplasty (THA) is the gold standard in the treatment of advanced hip osteoarthritis. However, hip resurfacing (HR) arthroplasty may present a viable alternative. The aim of this study was to compare complications, implant survivorship, and functional outcomes between HR and THA, to assess HR as a valid and safe alternative to THA. METHODS Inclusion criteria were randomized clinical trials (RCTs) published in English, comparing clinical outcomes and complications between HR and THA. A systematic review of the literature was performed on PubMed, Scopus and Cochrane Library, following the PRISMA 2020 statement, from January 1, 2015 to November 30, 2023. A meta-analysis was performed by Review Manager (RevMan) software version 5.4 to compare the rates of revisions, dislocations, infection, aseptic loosening and pseudotumor, and the clinical outcomes between the two groups. We used the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) to assess the risk of bias. RESULTS A total of 8 RCT were included, involving 844 patients (387 hips for HR group and 469 hips for THA group). The mean follow-up was 7.72 years. There were no statistically significant differences between the two groups for UCLA and WOMAC score, revision rate, infection, aseptic loosening and pseudotumor (all p > 0.05), while the dislocation rate was significantly lower in the HR group (p = 0.04). CONCLUSIONS HR is a safe and effective alternative to THA. However, several factors are involved to reduce the complication rate and achieve high implant survival.
Collapse
Affiliation(s)
- Pierangelo Za
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 - 00128, Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200 - 00128, Roma, Italy
| | - Carlo Casciaro
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 - 00128, Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200 - 00128, Roma, Italy
| | - Giuseppe Francesco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 - 00128, Roma, Italy.
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200 - 00128, Roma, Italy.
| | - Francesco Rosario Parisi
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 - 00128, Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200 - 00128, Roma, Italy
| | - Umile Giuseppe Longo
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 - 00128, Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200 - 00128, Roma, Italy
| | - Francesco Falez
- Department of Orthopaedics and Traumatology, S. Filippo Neri Hospital, ASL Roma 1, Rome, Italy
| | - Rocco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 - 00128, Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200 - 00128, Roma, Italy
| |
Collapse
|
5
|
Zampogna B, Parisi FR, Zampoli A, Prezioso A, Vorini F, Laudisio A, Papalia M, Papapietro N, Falez F, Papalia R. Accuracy of two-dimensional digital planning in uncemented primary hip arthroplasty: monocentric analysis of eight hundred implants. INTERNATIONAL ORTHOPAEDICS 2024; 48:1979-1985. [PMID: 38622366 DOI: 10.1007/s00264-024-06172-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 03/29/2024] [Indexed: 04/17/2024]
Abstract
PURPOSE In the last decades, there has been a refinement in total hip arthroplasty, which allowed surgeons to achieve the highest performance and better patient outcomes. Preoperative planning in primary hip arthroplasty is an essential step that guides the surgeon in restoring the anatomy and biomechanics of the joint. This study aims to evaluate the accuracy of the 2D digital planning, considering cup sizing, stem sizing, and limb length discrepancy. Additionally, we conducted a multivariable analysis of demographic data and comorbidities to find factors influencing preoperative planning. METHODS This retrospective study analyzed the planning accuracy in 800 consecutive uncemented primary total hip arthroplasty. We compared the preoperatively planned total hip arthroplasty with postoperative results regarding the planned component size, the implanted size, and the lower limb length restoration. Therefore, we investigated factors influencing planning accuracy: overweight and obesity, sex, age, past medical history, comorbidities, and implant design. All the surgeries were performed in the posterolateral approach by one expert surgeon who did the preoperative planning. The preoperative planning was determined to be (a) exact if the planned and the implanted components were the same size and (b) accurate if exact ± one size. The restoration of postoperative limb length discrepancy was classified into three groups: ± 3 mm, ± 5 mm, and ± 10 mm. This assessment was performed through a digital method 2D based on a standard hip X-ray. RESULTS This court of 800 implants showed that planning was exact in 60% of the cups and 44% of the stems and was accurate in 94% of the cups and 80% of the stems. The postoperative limb length discrepancy was ± 3 mm in 91% and ± 5 mm in 97%. CONCLUSIONS This study showed preoperative 2D digital planning great precision and reliability, and we demonstrated that it was accurate in 94% of the cups and 80% of the stems. Therefore, the preoperative limb length discrepancy analysis was essential to guarantee the recovery of the operated limb's correct length.
Collapse
Affiliation(s)
- Biagio Zampogna
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
- BIOMORF Department, Biomedical, Dental and Morphological and Functional Images, University of Messina. A.O.U. Policlinico "G.Martino", Messina, Italy
| | - Francesco Rosario Parisi
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| | - Andrea Zampoli
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| | - Anna Prezioso
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| | - Ferruccio Vorini
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| | - Alice Laudisio
- Department of Medicine, Research Unit of Geriatrics, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy.
- Fondazione Policlinico Universitario Campus Bio-Medico, Operative Research Unit of Geriatrics, Via Alvaro del Portillo, 200, 00128, Roma, Italy.
| | - Matteo Papalia
- Orthopaedic and Traumatology Department, Nuova Itor Clinic, Rome, Italy
| | - Nicola Papapietro
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| | - Francesco Falez
- Department of Orthopaedics and Traumatology, ASL Roma 1, S. Filippo Neri Hospital, Rome, Italy
| | - Rocco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| |
Collapse
|
6
|
Jones HB, Hinkle AJ, Liu Y, Sambandam SN. Multivariate Analysis of Risk Factors for In-Hospital Dislocation Following Primary Total Hip Arthroplasty. J Clin Med 2024; 13:3456. [PMID: 38929981 PMCID: PMC11204957 DOI: 10.3390/jcm13123456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Revised: 06/07/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024] Open
Abstract
Background: Early dislocation following primary total hip arthroplasty (THA) is a rare but devastating complication and represents a source of patient morbidity and financial burden to the healthcare system. The objective of this study was to identify patient characteristics and comorbidities that are associated with increased early in-hospital dislocation rates following primary THA. Methods: A retrospective cohort study was conducted using patient data from the Nationwide Inpatient Sample (NIS) database; we identified patients who had undergone THA from 2016 to 2019 and compared those with an early periprosthetic dislocation prior to discharge to those without. The patient characteristics and comorbidities were compared using univariate analysis with a subsequent investigation of statistically significant variables using multivariate analysis. The variables were compared using chi square, Fisher's exact test, and independent sample t-tests with data assessed using odds ratio with 95% confidence intervals. Results: A total of 5151 patients sustained an early dislocation compared to 362,743 who did not. Those who sustained an in-hospital dislocation were more likely to share the following characteristics: female sex (OR 1.21, p < 0.01), age > 70 (OR 1.45, p < 0.01), Caucasian ethnicity (OR 1.22, p < 0.01), SLE (OR 1.87, p < 0.01), and Parkinson's disease (OR 1.93, p < 0.01). Certain characteristics were also associated with decreased odds of having an in-hospital dislocation including elective surgery (OR 0.14, p < 0.01), tobacco use (OR 0.8, p < 0.01), diabetes without complications (OR 0.87, p < 0.01), and a history of heart valve replacement (OR 0.81, p < 0.01). The length of stay was significantly longer (4.7 days vs. 2.3 days) as was the total hospital charges (USD $101,517 vs. USD $66,388) for the early in-hospital dislocation group. Conclusions: Several patient characteristics and comorbidities are associated with early in-hospital dislocation episodes following total hip arthroplasty including female sex, age > 70, non-elective surgery, SLE, and Parkinson's. This information may be useful to help guide intraoperative implant selection and/or postoperative protocol in select patient populations to limit early instability as well as decrease the financial burden associated with this postoperative complication.
Collapse
Affiliation(s)
- Hunter B. Jones
- Department of Orthopedic Surgery, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390, USA; (A.J.H.); (Y.L.); (S.N.S.)
| | - Andrew J. Hinkle
- Department of Orthopedic Surgery, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390, USA; (A.J.H.); (Y.L.); (S.N.S.)
| | - Yida Liu
- Department of Orthopedic Surgery, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390, USA; (A.J.H.); (Y.L.); (S.N.S.)
| | - Senthil N. Sambandam
- Department of Orthopedic Surgery, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390, USA; (A.J.H.); (Y.L.); (S.N.S.)
- Department of Orthopedic Surgery, VA North Texas Health Care System, Dallas, TX 75216, USA
| |
Collapse
|
7
|
Shahbazi P, Jalilvand AH, Ghaseminejad-Raeini A, Ghaderi A, Sheikhvatan M, Fallah Y, Shafiei SH. Risk Factors for Dislocation following Total Hip Arthroplasty in Developmental Dysplasia of the Hip: A Systematic Review and Meta-Analysis. INTERNATIONAL ORTHOPAEDICS 2023; 47:3063-3075. [PMID: 37688602 DOI: 10.1007/s00264-023-05949-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 08/16/2023] [Indexed: 09/11/2023]
Abstract
PURPOSE This systematic review and meta-analysis aimed to identify risk factors of dislocation after total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). METHODS A systematic literature review was performed on 18th August 2022 using Medline, Embase, Scopus, Web of Science electronic databases, and a manual search. The study was conducted according to the PRISMA guidelines and registered with PROSPERO. Statistical analysis includes assessment of heterogeneity and data synthesis using RevMan 5.4. RESULTS Review of five studies including 2865 patients and 116 dislocated hips found that lower body mass index (BMI) (SMD = 0.22, p = 0.04, I2 = 0%), Crowe classification type IV versus I, II, and III (OR = 2.70, p = 0.004, I2 = 51%), higher cup inclination (SMD = 0.39 p = 0.0007, I2 = 0%), femoral head size < 28 mm (OR = 5.07, p = 0.003, I2 = 71%), lateral surgical approach (OR = 1.96, p = 0.02, I2 = 0%), and postoperative infection (OR = 6.26, p < 0.0001, I2 = 0%) were significant risk factors. However, age, gender, cup anteversion, femoral osteotomy, vertical (V-COR) centre of rotation, intraoperative fracture, preoperative and postoperative leg length discrepancy (LLD) and previous hip surgery were not found to be significant risk factors. CONCLUSION This study underscores importance of these risk factors in THA planning for DDH patients to reduce dislocation risk. Further research needed to understand mechanisms.
Collapse
Affiliation(s)
- Parmida Shahbazi
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Amir Hossein Jalilvand
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Amirhossein Ghaseminejad-Raeini
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Ali Ghaderi
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mehrdad Sheikhvatan
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
- Heidelberg Medical Hospital, Heidelberg, Germany
| | - Yousef Fallah
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Seyyed Hossein Shafiei
- Orthopedic Department, Orthopedic Surgery Research Center (OSRC), Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
8
|
Zampogna B, Papalia GF, Ferrini A, Torre G, Vorini F, Diaz Balzani LA, Farsetti P, Papalia R. Dual-mobility total hip arthroplasty in patients younger than 55 years old: a systematic review. Arch Orthop Trauma Surg 2023; 143:6821-6828. [PMID: 37062001 DOI: 10.1007/s00402-023-04882-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 04/09/2023] [Indexed: 04/17/2023]
Abstract
Total hip arthroplasty (THA) is regarded as one of the most successful and cost-effective orthopedic procedures. However, THA is a surgical procedure with potential intraoperative and postoperative risks. Dislocation is one of the common postoperative complications and remains one of the main indications for THA revision. The purpose of this systematic review was to evaluate the role and the outcomes of dual-mobility implant to prevent dislocation in patients younger than < 55 years in primary THA. In this systematic review, we included observational, prospective, and retrospective studies that evaluated the outcome and the complications of the dual-mobility cup in < 55-year-old patients. After applying exclusion criteria (femoral neck fractures or THA revision, case series, reviews, and meta-analyses), ten articles were included in the study. The overall number of participants in all the studies was 1530. The mean age of the participants was 50 years. The mean follow-up was 11.7 years. A total of 46 patients (2.7%) reported intraprosthetic dislocations, in which the polyethylene liner dissociates from the femoral head, while 4.8% of revision was due to aseptic loosening. The mean revision rate at twelve years was 11%. The mean value of Harris Hip Score increased from 50.9 pre-operatively to 91.6 after surgery. Dual mobility is a valid option for young patients with extended survivorship and low rates of instability and dislocation after primary THA.
Collapse
Affiliation(s)
- Biagio Zampogna
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Giuseppe Francesco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy.
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy.
| | - Augusto Ferrini
- Department of Clinical Science and Translational Medicine, Section of Orthopaedics and Traumatology, University of Rome "Tor Vergata", Rome, Italy
| | - Guglielmo Torre
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Ferruccio Vorini
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Lorenzo Alirio Diaz Balzani
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Pasquale Farsetti
- Department of Clinical Science and Translational Medicine, Section of Orthopaedics and Traumatology, University of Rome "Tor Vergata", Rome, Italy
| | - Rocco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| |
Collapse
|
9
|
Castagnini F, Cosentino M, Bordini B, Montalti M, Biondi F, Faldini C, Traina F. Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants. Hip Int 2023; 33:916-924. [PMID: 36127850 PMCID: PMC10486160 DOI: 10.1177/11207000221124115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 06/28/2022] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The routine use of proximal femoral modularity was discouraged in total hip arthroplasties (THAs). However, titanium dual-taper (DT) implants may provide some advantages over single-taper (ST) stems in cases of complex deformity. A registry study comparing ST and DT stems in dysplasia was designed, aiming to assess: (1) survival rates at long-term; (2) reasons for revision; (3) the profile of failed implants. METHODS The arthroplasty registry RIPO was investigated for cementless THAs performed for dysplasia since 2000. ST implants were compared to titanium-on-titanium DT stems. Demographics and implant features were collected. Survival rates and reasons for revision were compared. The profile of DT stem failures in dysplasia was defined. RESULTS 6429 implants were included in the study, 3642 ST and 2787 DT. The demographic and implant features of the 2 cohorts were not comparable. The DT cohort achieved higher survival rates at long-term (93.9% vs. 91.6%, p = 0.018). DT implants showed a higher rate of implant breakage (0.6%, p = 0.011) and a lower rate of aseptic loosening (p = 0.005). There were no differences in terms of revisions for dislocation. No metallosis occurred. There were more revisions in DT implants in males <65 years, with a 28-mm head size or smaller. CONCLUSIONS Modularity did not result in lower survival rates in dysplastic patients and may even reduce the rate of aseptic loosening in comparison to ST stems. The rate of implant breakage is not negligible. Younger males are not good candidates for titanium DT stems.
Collapse
Affiliation(s)
- Francesco Castagnini
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Monica Cosentino
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Barbara Bordini
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Maurizio Montalti
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Federico Biondi
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Cesare Faldini
- First Orthopaedic and Traumatology Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- University of Bologna, Italy
| | - Francesco Traina
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- University of Bologna, Italy
| |
Collapse
|
10
|
Krull P, Steinbrück A, Grimberg AW, Melsheimer O, Morlock MM, Perka C. [Standard and special liner in primary hip arthroplasty : Current study and survey results from the German Arthroplasty Registry (EPRD)]. ORTHOPADIE (HEIDELBERG, GERMANY) 2023; 52:222-232. [PMID: 36635446 DOI: 10.1007/s00132-022-04333-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 11/25/2022] [Indexed: 01/13/2023]
Abstract
BACKGROUND Instability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD). The study investigated mechanical failure of standard and modified liner designs in primary, cementless total hip arthroplasty. Following the study, the EPRD conducted a survey of German clinics to research the utilization of lipped liners in primary total hip replacement. METHODS The liner study included 151,096 primary, elective, cementless total hip arthroplasties. Data from November 2012 to November 2020 were obtained from the EPRD. Standard polyethylene liners were compared with lipped, angulated, offset and angulated/offset inlays. Cumulative incidences for endpoint revision due to mechanical complication were calculated with a competing risk analysis. The influence of other variables was investigated with a multivariate Cox regression. In the following online survey, 237 out of 789 hospitals completed a form. RESULTS AND CONCLUSION In our analysis, only offset liners were, compared to standard liners, associated with a reduced risk of mechanical failure in a short to medium follow up. However, the resultant joint reaction force is increased with offset liners due to the lateralization of the hip center of rotation. Thus, the long-term performance of offset liners needs to be observed. Our survey indicated that lipped liners were implanted more often if the posterior approach was used. Moreover, lipped liners were mostly positioned with the elevated rim in the biomechanically less optimal posterior-superior quadrant. To improve stability it is suggested to position the elevated rim in the posterior-inferior quadrant.
Collapse
Affiliation(s)
- Paula Krull
- Endoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland. .,Centrum für Muskuloskeletale Chirurgie (CMSC), Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Deutschland.
| | - Arnd Steinbrück
- Endoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland.,Orthopädisch Chirurgisches Kompetenzzentrum Augsburg (OCKA), Vinzenz-von-Paul-Platz 1, 86152, Augsburg, Deutschland
| | - Alexander W Grimberg
- Endoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland
| | - Oliver Melsheimer
- Endoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland
| | - Michael M Morlock
- Technische Universität Hamburg (TUHH), Am Schwarzenberg-Campus 1, 21073, Hamburg, Deutschland
| | - Carsten Perka
- Centrum für Muskuloskeletale Chirurgie (CMSC), Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Deutschland
| |
Collapse
|
11
|
Peng L, Zeng Y, Wu Y, Si H, Pei F, Shen B. Radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty: a retrospective study with propensity score matching. Arch Orthop Trauma Surg 2022; 142:3995-4005. [PMID: 34821944 DOI: 10.1007/s00402-021-04263-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 11/12/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND Dislocation is a complicated process and associated with multivariate etiology and risk factors. The purpose of this study was to verify if radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty (THA) individually or synergistically. METHODS From 2017 to 2020, we identified 76 (1.9%) patients who suffered postoperative dislocations from 3926 THAs in our institution. After excluded patients with previously proven patient-related and implant-related risk factors, the remaining patients were used to match a 1:1 control patients who were without dislocation. The cup position (inclination and anteversion angles), hip offset (HO), leg length discrepancy (LLD), and abductor lever arm (ALA) were analyzed by univariate analyses and multivariate logistic regressions. RESULTS Measurements on radiographs showed excellent interobserver agreement (intraclass correlation coefficient (ICC) 0.922-0.952) and intraobserver agreements (ICC 0.933-0.967). HO restoration inaccuracy (without ± 5 mm) was associated with higher dislocation risk (OR 4.241 95% CI 1.440-12.492, P = 0.009). The restoration inaccuracy of the cup position, LLD, or ALA could not increase the dislocation risk individually. When combining the radiologic restoration inaccuracy factors, the HO + LLD restoration inaccuracy and HO + ALA restoration inaccuracy increased the odds of postoperative dislocation (OR 12.056, 95% CI 1.409-103.127, P = 0.023; OR 4.770, 95% CI 1.336-17.028, P = 0.016, respectively). Combining the four risk factors of cup safe zone, HO, LLD, and ALA, patients with 3 or 4 radiologic restoration inaccuracy factors showed a higher risk of dislocation (OR 13.500, 95% CI 1.340-135.983, P = 0.027). CONCLUSION Hip offset (HO) restoration inaccuracy increased the risk of dislocation following primary THA. Multivariate radiologic restoration accuracy is critical for the prevention of dislocation and needs to be valued by surgeons.
Collapse
Affiliation(s)
- Linbo Peng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Yi Zeng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Yuangang Wu
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Haibo Si
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Fuxing Pei
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Bin Shen
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China.
| |
Collapse
|
12
|
Longo UG, Papalia R, Salvatore G, Tecce SM, Jedrzejczak A, Marcozzi M, Piergentili I, Denaro V. Epidemiology of revision hip replacement in Italy: a 15-year study. BMC Surg 2022; 22:355. [PMID: 36195866 PMCID: PMC9531216 DOI: 10.1186/s12893-022-01785-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 08/25/2022] [Indexed: 11/21/2022] Open
Abstract
Background Over the past two decades, there has been an increase in the amount of primary total hip arthroscopies (THA) which in turn has increased the need for THA revision surgeries. The purpose of this study was to quantify the increase in THA revision in Italy, evaluate the causes and types of THA procedures performed.
Methods The data regarding revision hip prosthetic replacements performed both in public and private structures between 2001 and 2015 was collected by the National Hospital Discharge reports (SDO) carried out by the Italian Ministry of Health. Results Overall, 109,746 Revision Hip Replacements (RHR) were performed in Italy from 2001 to 2015 in the adult population. The study shows a greater number of female patients underwent surgery between 2001 and 2015 and the 75- to 79-year age group had the highest incidence of THA revision. The main causes for THA revision were found to be “Mechanical complication of internal orthopedic device implant and graft” (31.5%), “Infection and inflammatory reaction due to internal joint prosthesis” (10.5%) and “Mechanical loosening of prosthetic joint” (8.3%). Conclusions Revision hip replacement is growing and heavily affecting the population between 65 and 89 years and the main causes of THA revision have been quantified. The average length of hospitalization (LOS) was found to have decreased over the 14-year study period. Understanding the causes and risk factors for revision is essential in identifying avoidable complications and improving preventative care for patients undergoing primary implantation to decrease the revision burden.
Collapse
Affiliation(s)
- Umile Giuseppe Longo
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy. .,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy. .,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy.
| | - Rocco Papalia
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| | - Giuseppe Salvatore
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| | - Salvatore Maria Tecce
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| | - Alexander Jedrzejczak
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| | - Martina Marcozzi
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| | - Ilaria Piergentili
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| | - Vincenzo Denaro
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Via Alvaro del Portillo, 200, Trigoria, 00128, Rome, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.,Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy
| |
Collapse
|
13
|
Jungwirth-Weinberger A, Schmidt-Braekling T, Rueckl K, Springer B, Boettner F. Anterior hip replacement: lower dislocation rates despite less restrictions? Arch Orthop Trauma Surg 2022; 142:2413-2417. [PMID: 33687529 DOI: 10.1007/s00402-021-03849-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 02/27/2021] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Dislocation in Total hip arthroplasty (THA) is a common postoperative complication and reason for revision surgery. The direct anterior approach has become more popular over the last decade. The purpose of this study was to compare postoperative dislocation rates of the direct anterior and the posterior approach at a one-year follow-up. MATERIAL AND METHODS 797 consecutive hips operated through a posterior approach [698 patients (307 male, 391 female)] between 2009 and 2012, were compared to 690 selected THA [610 patients (423 female, 187 male)] operated since 2012. Anterior hip replacement surgery was primarily indicated for patients demanding increased flexibility after surgery (Yoga) or were considered a higher risk for dislocation. RESULTS During a one-year follow-up there were eight dislocations out of 797 THA (1%) in the posterior group and none in the 690 THA (0%) in the anterior group (p-value of 0.008). Average time to dislocation was 7.5 weeks in the posterior group. Five of eight patients with dislocations needed revision surgery due to persistent instability. CONCLUSION Even in a higher-risk patient population, the direct anterior approach showed a lower dislocation rate compared to the posterior approach in the first year after surgery.
Collapse
Affiliation(s)
- Anna Jungwirth-Weinberger
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
- Kantonsspital Baden, Im Ergel 1, 5404, Baden, Switzerland
| | | | - Kilian Rueckl
- Julius-Maximilians-Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Germany
| | | | - Friedrich Boettner
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| |
Collapse
|
14
|
Krull P, Steinbrück A, Grimberg AW, Melsheimer O, Morlock M, Perka C. Modified acetabular component liner designs are not superior to standard liners at reducing the risk of revision : an analysis of 151,096 cementless total hip arthroplasties from the German Arthroplasty Registry. Bone Joint J 2022; 104-B:801-810. [PMID: 35775174 DOI: 10.1302/0301-620x.104b7.bjj-2021-1791.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
AIMS Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). METHODS We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. RESULTS Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). CONCLUSION The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision. Cite this article: Bone Joint J 2022;104-B(7):801-810.
Collapse
Affiliation(s)
- Paula Krull
- Charite - Center for Musculosceletal Surgery, Berlin, Germany
| | - Arnd Steinbrück
- German Arthroplasty Registry (EPRD Deutsches Endoprothesenregister), Berlin, Germany
| | - Alexander W Grimberg
- German Arthroplasty Registry (EPRD Deutsches Endoprothesenregister), Berlin, Germany
| | - Oliver Melsheimer
- German Arthroplasty Registry (EPRD Deutsches Endoprothesenregister), Berlin, Germany
| | - Michael Morlock
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Carsten Perka
- Charite - Center for Musculosceletal Surgery, Berlin, Germany
| |
Collapse
|
15
|
Dion CA, Schmidt-Braekling T, Falsetto A, Kreviazuk C, Beaulé PE, Grammatopoulos G. Does Surgical Approach Influence the Natural History of the Unstable Total Hip Arthroplasty? J Arthroplasty 2022; 37:787-794. [PMID: 34923093 DOI: 10.1016/j.arth.2021.12.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 11/19/2021] [Accepted: 12/10/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Dislocation following total hip arthroplasty (THA) is a significant complication that occurs in 0.3%-10% of cases with 13%-42% of patients requiring revision surgery. The literature has primarily focused on the dislocation risk associated with different surgical approaches. However, little is known about the natural history of the dislocated hip and whether surgical approach of the index THA is associated with further instability and revision surgery. METHODS This is a retrospective, single-center, multi-surgeon consecutive case series of all patients who experienced THA dislocation from 2002 to 2020. Patients were excluded if the initial dislocation was secondary to infection or fracture. The natural history of the cohort as per approach was determined. Outcome measurements of interest were the number of dislocations; the treatment surrounding each dislocation; the necessity and type of revision; and the complications encountered. RESULTS Of the 75 patients, 58 (77%) dislocated within 6 months following primary THA. The anterior group had greater odds of dislocation within 2 weeks post-THA compared to the lateral and posterior groups (P = .04). The mean number of dislocations per patient was significantly lower in the anterior (1.5 ± 0.7) compared to the lateral (2.4 ± 1.2) and posterior (2.1 ± 1.0) groups (P = .02). Revision surgery was needed in 30% (6/20) of patients in the anterior, 69% (25/36) of the posterior, and 68% (13/19) of the lateral groups (P = .01). CONCLUSION This study illustrates that while primary THA dislocations happen earlier with the anterior approach, they are typically less complicated and have a lower risk of recurrent instability and revision surgery.
Collapse
Affiliation(s)
- Charles-Antoine Dion
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Tom Schmidt-Braekling
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Amedeo Falsetto
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Cheryl Kreviazuk
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
| | - Paul E Beaulé
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
| | | |
Collapse
|
16
|
Analysis of Clinical Effect after Treatment of Patients with Femoral Neck Fracture Using Total or Hemihip Arthroplasty. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:7422229. [PMID: 35242212 PMCID: PMC8888047 DOI: 10.1155/2022/7422229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Revised: 01/05/2022] [Accepted: 02/04/2022] [Indexed: 01/10/2023]
Abstract
OBJECTIVE To investigate the difference in clinical outcomes between total hip arthroplasty (THA) and hemiarthroplasty (HA) in patients with femoral neck fracture. METHOD To retrospectively analyze 96 patients (96 hips) with femoral neck fracture treated in our hospital and distinguish them into THA group (50 patients with 50 hips) and HA group (46 patients with 46 hips) according to the difference of their chosen surgical procedure, and to compare the difference in perioperative indexes, postoperative hip function, occurrence of near and long-term complications, long-term imaging performance, and revision rate between the two groups. RESULT The operating time, intraoperative blood loss, and total drainage were greater in the THA group than in the HA group (P < 0.05). At 6 months after surgery, the Harris score of the hip joint was higher in the HA group than in the THA group. At 3 years after surgery, the Harris score was higher in the THA group than in the HA group (P < 0.05). At 3 years after surgery, the excellent hip function rates were 86.00% and 67.39% in the THA and HA groups, respectively, with statistically significant difference between the groups. The incidence of long-term complications was significantly lower in the THA group than in the HA group (P < 0.05). The anteversion and abduction angles of patients in the HA group were smaller than those in the THA group at 6 months after surgery (P < 0.05). The WOMAC scores of the THA group were better than those of the HA group at 3 years after surgery (P < 0.05). CONCLUSION Compared with hemiarthroplasty, total hip arthroplasty has a longer operative time and more postoperative bleeding, but the complication rate is relatively lower in the long term, and the patients have better long-term hip function recovery, so total hip arthroplasty is recommended for patients with femoral neck fracture with an expected survival time longer than 3 years.
Collapse
|
17
|
Upfill-Brown A, Hsiue PP, Sekimura T, Patel JN, Adamson M, Stavrakis AI. Instability Is the Most Common Indication for Revision Hip Arthroplasty in the United States: National Trends From 2012 to 2018. Arthroplast Today 2021; 11:88-101. [PMID: 34504922 PMCID: PMC8413665 DOI: 10.1016/j.artd.2021.08.001] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 07/23/2021] [Accepted: 08/02/2021] [Indexed: 11/26/2022] Open
Abstract
Background As primary total hip arthroplasty volume continues to increase, so will the number of revision total hip arthroplasty (rTHA) procedures. These complex cases represent a significant clinical and financial burden to the health-care system. Methods This was a retrospective review using the National Inpatient Sample. International Classification of Diseases, 9th and 10th revision codes were used to identify patients who underwent rTHA and create cohorts based on rTHA indications from 2012 to 2018. National and regional trends for length of stay (LOS), cost, and discharge location were evaluated. Results A total of 292,250 rTHA procedures were identified. The annual number of rTHA procedures increased by 28.1% from 2012 to 2018 (37,325 to 47,810). The top 3 indications for rTHA were instability (20.4%), aseptic loosening (17.8%), and infection (11.1%). Over the study period, the proportion of patients discharged to skilled nursing facility decreased from 44.2% to 38% (P < .001). Hospital LOS decreased on average from 4.8 to 4.4 days (P < .001). Infections had the highest average LOS (7.3 days) followed by periprosthetic fractures (6.5 days). Hospital costs decreased over the study period, from $25,794 to $24,555 (P < .001). The proportion of rTHA cases performed at urban academic centers increased (58.0% to 75.3%, P < .001) while the proportion performed at urban nonacademic centers decreased (35.5% to 19.4%, P < .001). Conclusion Instability was the most common indication for rTHA between 2012 and 2018. The proportion of rTHA performed in urban academic centers has increased substantially, away from urban nonacademic centers. While cost and LOS have decreased, significant geographic variability exists.
Collapse
Affiliation(s)
| | | | | | | | | | - Alexandra I. Stavrakis
- Corresponding author. 1250 16 Street, Suite 2100, Santa Monica, CA 90404, USA. Tel.: +1-424-259-9804.
| |
Collapse
|
18
|
Jiang M, Coles-Black J, Chen G, Alexander M, Chuen J, Hardidge A. 3D Printed Patient-Specific Complex Hip Arthroplasty Models Streamline the Preoperative Surgical Workflow: A Pilot Study. Front Surg 2021; 8:687379. [PMID: 34513912 PMCID: PMC8427196 DOI: 10.3389/fsurg.2021.687379] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 07/28/2021] [Indexed: 12/05/2022] Open
Abstract
Introduction: Surgical planning for complex total hip arthroplasty (THA) often presents a challenge. Definitive plans can be difficult to decide upon, requiring unnecessary equipment to be ordered and a long theatre list booked. We present a pilot study utilising patient-specific 3D printed models as a method of streamlining the pre-operative planning process. Methods: Complex patients presenting for THA were referred to the research team. Patient-specific 3D models were created from routine Computed Tomography (CT) imaging. Simulated surgery was performed to guide prosthesis selection, sizing and the surgical plan. Results: Seven patients were referred for this pilot study, presenting with complex conditions with atypical anatomy. Surgical plans provided by the 3D models were more detailed and accurate when compared to 2D CT and X ray imaging. Streamlined equipment selection was of great benefit, with augments avoided post simulation in three cases. The ability to tackle complex surgical problems outside of the operating theatre also flagged potential complications, while also providing teaching opportunities in a low risk environment. Conclusion: This study demonstrated that 3D printed models can improve the surgical plan and streamline operative logistics. Further studies investigating the optimal 3D printing material and workflow, along with cost-benefit analyses are required before this process is ready for routine use.
Collapse
Affiliation(s)
- Michael Jiang
- 3dMedLab, Austin Health, The University of Melbourne, Parkville, VIC, Australia
- Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, VIC, Australia
| | - Jasamine Coles-Black
- 3dMedLab, Austin Health, The University of Melbourne, Parkville, VIC, Australia
- Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, VIC, Australia
| | - Gordon Chen
- 3dMedLab, Austin Health, The University of Melbourne, Parkville, VIC, Australia
| | - Matthew Alexander
- Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, VIC, Australia
| | - Jason Chuen
- 3dMedLab, Austin Health, The University of Melbourne, Parkville, VIC, Australia
- Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, VIC, Australia
| | - Andrew Hardidge
- Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, VIC, Australia
| |
Collapse
|
19
|
Van Nest DS, Li WT, Kozick Z, Smith EB, Hozack WJ, Courtney PM. Dual Mobility and Conventional Bearings Have Comparably Low Dislocation Rates for Anterior-Based Approaches in Total Hip Arthroplasty. J Arthroplasty 2021; 36:1695-1699. [PMID: 33468345 DOI: 10.1016/j.arth.2020.12.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/25/2020] [Accepted: 12/14/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Dual mobility (DM) bearings for total hip arthroplasty (THA) have been proposed to reduce the risk of instability in select patients, especially those undergoing revision surgery. The use of DM bearings has not been studied as extensively for use in primary THA. The purpose of this study is to compare outcomes following primary THA with anterior-based approaches between patients receiving DM bearings vs standard bearing hip implants. METHODS We retrospectively reviewed a consecutive series of patients undergoing primary THA through an anterior-based approach. A 3:1 propensity score match was performed between the standard and DM bearing patients to control for possible risk factors for instability. Functional outcomes, dislocations, and aseptic revisions were identified for each patient. The effect of DM on postoperative outcomes was determined using univariate statistical analyses. RESULTS In total, 250 DM bearings were compared to 753 standard bearings. We found no difference in dislocation rate between single bearings and DM bearings (0.53% vs 0.4%). There was 1 DM dislocation occurring in a liner with outer diameter of 38 mm. There were no DM dislocations with outer diameter >38 mm. Aseptic revision surgery was more common in DM. This difference was driven by higher incidence of femoral periprosthetic fracture. There were no differences in functional outcomes. CONCLUSION Dislocation rates are comparably low between DM bearings and standard bearings for THA done using an anterior approach to the hip. Further investigation is needed to determine if specific patient populations may benefit from DM implants for primary THA when an anterior approach to the hip is being used.
Collapse
Affiliation(s)
- Duncan S Van Nest
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - William T Li
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Zachary Kozick
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Eric B Smith
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - William J Hozack
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - P Maxwell Courtney
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| |
Collapse
|
20
|
Arbeloa-Gutierrez L, Arenas-Miquelez A. Atraumatic Anterior Hip Dislocation as High Grade of Hip Instability: A Case Report. JBJS Case Connect 2021; 11:01709767-202106000-00024. [PMID: 33979811 DOI: 10.2106/jbjs.cc.20.00542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE Fifty-year-old woman who presented an atraumatic anterior hip dislocation during a local traditional dance exhibition. The dislocation occurred during a dance step in which extreme hip position in extension and external rotation was held. After urgent closed reduction under general anesthesia, the patient underwent conservative management with a follow-up of 24 months. There were no further dislocation events or sequelae, with the Hip Disability and Osteoarthritis Outcome Score-12 scale score was 100 points at the end of follow-up. CONCLUSIONS Atraumatic hip dislocation is the highest grade and exceptional presentation of hip instability and requires immediate treatment. Conservative treatment is satisfactory, although in case of recurrence or persistent residual symptoms, other treatments are warrant.
Collapse
|
21
|
Masionis P, Vileikis TP, Kvederas G, Uvarovas V, Šatkauskas I, Sveikata T, Kurtinaitis J. Risk Factors for Revision After Early and Delayed Total Hip Arthroplasty Dislocation. An Analysis of Lithuanian Arthroplasty Register. Cureus 2021; 13:e14155. [PMID: 33936869 PMCID: PMC8078143 DOI: 10.7759/cureus.14155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Introduction: Despite relatively low incidence, dislocation remains one of the main reasons for total hip arthroplasty (THA) revision. It is a devastating complication for a patient and a surgeon, and has high burden on the healthcare system. The aim of the present study was to assess and compare the risk factors for revision after early and delayed THA dislocations. Methods: Some 3403 THA through posterior approach for primary osteoarthritis were retrospectively studied in the Lithuanian Arthroplasty Register from 2011 to 2018. Three months after THA was the splitting time between the first event of early and delayed dislocations. Revision was set as outcome measure. Gender, affected side, number of dislocations, femoral head and neck size, and prosthesis fixation type were tested as risk factors for revision after early and delayed THA dislocations. Results: Dislocation occurred in 108 patients (3.2%), and 26 cases (0.8%) required revision. Men had statistically significant higher risk for revision due to early dislocation [hazard ratio (HR) 4.7; 1.3-17.7 confidence interval (CI)] and considerably lower risk for revision due to delayed dislocation (HR 0.5; 0.1-1.7 CI). The left side THA had twice the risk as compared to the right in the early settings (HR 2.1; 0.6-6.9 CI) which equalized after three months (HR 1.1; 0.4-3.1 CI). Some 32 mm femoral head had significantly lower risk in the early group as compared to 28 mm head (HR 0.3; 0.1-0.5 CI). Short head was associated with increased risk for revision after early dislocation, although, not statistically significant. Prosthesis fixation type was not a risk factor for revision surgery neither after early nor after delayed dislocation. Conclusion: The unique finding of gender separation was found -- men tend for revision after early dislocation and women after delayed dislocation. In early stage, additional precautions should be considered when 28 mm short metal heads are used.
Collapse
Affiliation(s)
- Povilas Masionis
- Centre of Orthopedics and Traumatology, Vilnius University Hospital Santaros Clinics, Vilnius, LTU
| | - Tomas P Vileikis
- Centre of Orthopedics and Traumatology, Faculty of Medicine, Vilnius University, Vilnius, LTU
| | - Giedrius Kvederas
- Centre of Orthopedics and Traumatology, Vilnius University Hospital Santaros Clinics, Vilnius, LTU
| | - Valentinas Uvarovas
- Centre of Orthopedics and Traumatology, Republican Vilnius University Hospital, Vilnius, LTU
| | - Igoris Šatkauskas
- Centre of Orthopedics and Traumatology, Republican Vilnius University Hospital, Vilnius, LTU
| | - Tomas Sveikata
- Centre of Orthopedics and Traumatology, Republican Vilnius University Hospital, Vilnius, LTU
| | - Jaunius Kurtinaitis
- Centre of Orthopedics and Traumatology, Republican Vilnius University Hospital, Vilnius, LTU
| |
Collapse
|
22
|
Abstract
INTRODUCTION Dislocation after total hip arthroplasty (THA) is the most common cause of revision hip surgery in the United States, ahead of aseptic loosening and infection, and is responsible for considerable economic cost related to frequent readmission and/or revision surgery. The aim of this article is to identify the clinical and radiological factors related to the unstable total hip replacement. METHODS We performed a literature search to assess current strategies to define clinical and radiological characteristics of dislocation after primary THA using the PubMed platform. The characteristics related to THA instability were divided into patient related factors, implant related factors and surgeon experience. RESULTS Patient-related factors for instability identified are: age; inflammatory joint disease; prior hip surgery; preoperative diagnosis; comorbidity; ASA score; presence of spino-pelvic abnormality; and neurological disability. Gender, simultaneous bilateral THA and restrictive postoperative precautions do not influence rate of THA dislocation. Implant related factors identified are: surgical approach; component malposition; femoral head size; and the use of dual-mobility or constrained solution. Surgeon experience also reduces the rate of dislocation. DISCUSSION Dislocation is a major complication of THAs, and causes include patient-derived factors, surgical factors, or both. It is imperative to determine the cause of the instability via a complete patient and radiographic evaluation and to adjust the reconstruction strategy accordingly.
Collapse
Affiliation(s)
- Loris Perticarini
- Orthopaedic and Traumatology, Fondazione Poliambulanza, Brescia, Italy
| | - Stefano M P Rossi
- Orthopaedic and Traumatology, Fondazione Poliambulanza, Brescia, Italy
| | - Francesco Benazzo
- Orthopaedic and Traumatology, Fondazione Poliambulanza, Brescia, Italy
| |
Collapse
|
23
|
Wang X, Qureshi A, Vepa A, Rahman U, Palit A, Williams MA, King R, Elliott MT. A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty. SENSORS 2020; 20:s20216182. [PMID: 33143034 PMCID: PMC7663251 DOI: 10.3390/s20216182] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 10/26/2020] [Accepted: 10/27/2020] [Indexed: 11/16/2022]
Abstract
There is increasing evidence that pelvic mobility is a critical factor to consider in implant alignment during total hip arthroplasty (THA). Here, we test the feasibility of using an inertial sensor fitted across the sacrum to measure change in pelvic tilt, and hence screen for patients with high pelvic mobility. Patients (n = 32, mean age: 57.4 years) due to receive THA surgery participated in the study. Measures of pelvic tilt were captured simultaneously using the device and radiograph in three functional positions: Standing, flexed-seated, and step-up. We found a strong correlation between the device and radiograph measures for the change in pelvic tilt measure from standing to flexed-seated position (R2 = 0.911); 75% of absolute errors were under 5 degrees. We demonstrated that the device can be used as a screening tool to rapidly identify patients who would benefit from more detailed surgical planning of implant positioning to reduce future risks of impingement and dislocation.
Collapse
Affiliation(s)
- Xueyang Wang
- WMG, University of Warwick, Coventry CV4 7AL, UK; (X.W.); (A.P.); (M.A.W.)
| | - Arham Qureshi
- University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK; (A.Q.); (A.V.); (U.R.); (R.K.)
| | - Abhinav Vepa
- University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK; (A.Q.); (A.V.); (U.R.); (R.K.)
| | - Usama Rahman
- University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK; (A.Q.); (A.V.); (U.R.); (R.K.)
| | - Arnab Palit
- WMG, University of Warwick, Coventry CV4 7AL, UK; (X.W.); (A.P.); (M.A.W.)
| | - Mark A. Williams
- WMG, University of Warwick, Coventry CV4 7AL, UK; (X.W.); (A.P.); (M.A.W.)
| | - Richard King
- University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK; (A.Q.); (A.V.); (U.R.); (R.K.)
| | - Mark T. Elliott
- WMG, University of Warwick, Coventry CV4 7AL, UK; (X.W.); (A.P.); (M.A.W.)
- Correspondence:
| |
Collapse
|
24
|
Novel Constrained Dual Mobility Hip Prosthesis to Combat Instability in Revision Total Hip Arthroplasty whilst Preserving Normal Function. Case Rep Orthop 2020; 2020:6390310. [PMID: 32724692 PMCID: PMC7364194 DOI: 10.1155/2020/6390310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 06/26/2020] [Accepted: 06/30/2020] [Indexed: 12/04/2022] Open
Abstract
We present the case of a male patient with sepsis and a chronic discharging sinus in a multirevised total hip replacement. Following extensive debridement, the reimplanted hip became unstable. With the patient's long-term desire to return to work and ride a bicycle with his children, the patient agreed to proceed with a novel, custom-designed, constrained dual mobility liner which allowed unrestricted movement. In 2017, the patient underwent revision surgery with this novel dual mobility constrained prosthesis. The patient was very quickly able to regain independence. After 16 years of unemployment, he managed to return to gainful employment as a cleaner rapidly regaining function as well as finally being able to ride a bike with his children for the first time.
Collapse
|
25
|
Knoth C, Zettl R, Markle A, Dullenkopf A, Bruhin V, Hess F. A retrospective analysis of surgical outcomes following direct anterior hip arthroplasty with or without a surgical extension table. INTERNATIONAL ORTHOPAEDICS 2020; 44:1701-1709. [PMID: 32435953 DOI: 10.1007/s00264-020-04596-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Accepted: 04/27/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE Using a surgical extension table during total hip arthroplasty (THA) is widely considered state-of-the-art. However, intra-operative leg positioning requires additional time and leg length determination can be challenging. Our study's aim was to compare patient outcomes, particularly leg length precision, following surgery with or without an extension table. METHODS This retrospective study included data from medical records of 324 patients who underwent THA using the direct anterior approach by one surgeon at a Swiss cantonal hospital (2015-2017). Patients were grouped by table type-standard (TS) or extension table (TE). Variables analyzed were demographics, operative/anaesthetic conditions, and medical outcomes. The leg length was measured pre- and post-operatively with mediCAD Classic®. RESULTS An extension table was used in 161 (49.7%) patients. The median operative duration (minutes) was shorter in TS (55 (interquartile range (IQR) 48-67) than TE (60 (IQR 54-69)) (p = 0.002) and blood loss (ml) was lower (TS = 400 (IQR 300-500), TE = 500 (IQR 300-600), p = 0.0175). The median post-operative leg length discrepancy (mm) was less in TS (TS = 1 (IQR 0-3), TE = 2 (IQR 0-4), p = 0.0122). All four dislocations occurred in TE, and 7.4% of patients had complications (TS = 7%, TE = 7.5%, p = 0.99). CONCLUSION We found that operating on a standard table during THA resulted in slightly more favourable outcomes. Given the added expenses, human resources, and time associated with an extension table, opting for a standard table remains a sensible choice.
Collapse
Affiliation(s)
- Christoph Knoth
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Ralph Zettl
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Andrew Markle
- Institute of Anesthesia and Intensive Care Medicine, Spital Thurgau Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Alexander Dullenkopf
- Institute of Anesthesia and Intensive Care Medicine, Spital Thurgau Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Valentino Bruhin
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Florian Hess
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland.
| |
Collapse
|
26
|
Ding ZC, Zeng WN, Mou P, Liang ZM, Wang D, Zhou ZK. Risk of Dislocation After Total Hip Arthroplasty in Patients with Crowe Type IV Developmental Dysplasia of the Hip. Orthop Surg 2020; 12:589-600. [PMID: 32227469 PMCID: PMC7189031 DOI: 10.1111/os.12665] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 02/16/2020] [Accepted: 02/29/2020] [Indexed: 02/05/2023] Open
Abstract
Objective To investigate whether the risk of dislocation after total hip arthroplasty (THA) in patients with Crowe type IV developmental dysplasia of the hip (DDH) is high and to further identify the risk factors for postoperative dislocation in these patients. Methods This retrospective cohort study reviewed Crowe type IV DDH patients undergoing THA between January 2009 and December 2017 in our institution. Each Crowe type IV DDH patient was matched with three Crowe type I, II, or III DDH patients according to gender, side and date of operation. The primary outcome of this study was postoperative dislocation after THA. Occurrence, rate, classification, treatment and outcome of dislocation were documented in detail for all patients. The dislocation rates were compared between Crowe type IV DDH patients and Crowe type I, II, or III DDH patients. Demographic data, implant factors, and surgical factors were compared between the dislocation and no dislocation groups. Multiple logistic regression analysis was used to determine the independent risk factors for dislocation in Crowe type IV hips. Results A total of 131 Crowe type IV hips were followed up for a mean of 76.5 ± 28.1 months. Three hundred and ninety‐three Crowe type I, II and III hips, including 261 type I hips, 94 type II hips, and 38 type III hips, were identified as controls and followed up for a mean of 76.4 ± 28.2 months. No significant difference was observed in follow‐up time between two groups (P = 0.804). One or more dislocations occurred in 22 of the 524 dysplasia hips (4.20%). Of the 22 dislocated hips, 20 hips (90.9%) were successfully managed with non‐operative treatment. Two patients (9.1%, one Crowe type I and one Crowe type IV) experienced recurrent dislocation and required revision surgery. Crowe type IV hips had a significantly higher postoperative dislocation rate than type I, II, and III hips (11.45% vs 1.78%, P < 0.001). The use of a 22‐mm femoral head (odds ratio [OR] = 23.55, 95% confidence interval [CI] = 1.901–291.788, P = 0.014), older age (OR = 1.128, 95% CI = 1.037–1.275, P = 0.031), and absence of false acetabulum (OR = 12.425, 95% CI = 1.982–77.879, P = 0.007) were identified as independent risk factors for dislocation in Crowe type IV hips. Conclusions Crowe type IV DDH patients were at a high risk of dislocation after THA, and using large femoral heads and improving abductor muscle strength may help decrease the rate of postoperative dislocation in such patients.
Collapse
Affiliation(s)
- Zi-Chuan Ding
- Department of Orthopaedics, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
| | - Wei-Nan Zeng
- Department of Orthopaedics, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
| | - Ping Mou
- Department of Orthopaedics, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
| | - Zhi-Min Liang
- Clinic Research Management Department, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
| | - Duan Wang
- Department of Orthopaedics, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
| | - Zong-Ke Zhou
- Department of Orthopaedics, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
| |
Collapse
|
27
|
Yoshitani J, Kabata T, Kajino Y, Ueno T, Ueoka K, Yamamuro Y, Tsuchiya H. Anatomic stem inserted according to native anteversion could reproduce the native anterior distance of the femoral head and decrease bony impingement in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2019; 44:245-251. [PMID: 31456058 DOI: 10.1007/s00264-019-04394-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 08/14/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE To investigate whether anatomic and straight stems could reproduce the anteroposterior distance (AD) of the native femoral head and evaluate the effect of AD of the femoral head on range of motion (ROM) and bony impingement. METHODS This retrospective simulation study included 64 patients who had undergone primary total hip arthroplasty between 2012 and 2014. Using computed tomography (CT)-based templating software, anatomic and straight stems were inserted with same alignment. AD of the head centre was compared between the two stems and native anatomy. Furthermore, post-operative ROM was calculated, and correlation between AD and ROM was assessed. RESULTS There was a strong positive correlation between native anteversion (mean 21.9°) and anatomic stem anteversion (mean 22.5°) (R = 0.975, P < 0.001). There was no significant difference in AD between the native and anatomic stems (mean 37.7 and 38.8 mm, respectively), but AD of the straight stem was significantly lower than that of the native and anatomic stems. The straight stem showed a significantly lower ROM in flexion and internal rotation angles with 90° flexion (IR) than the anatomic stem (P < 0.05 and P < 0.001, respectively). AD showed a stronger correlation with ROM of IR than with stem anteversion. CONCLUSIONS The anatomic stem could reproduce AD of the native femoral head centre, but the head centre of the straight stem in the same anteversion with anatomic stem translated significantly posterior, significantly decreasing the ROM of flexion and IR and increasing bony impingement of IR. To avoid bony impingement and acquire sufficient ROM, reproducing AD was important.
Collapse
Affiliation(s)
- Junya Yoshitani
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Tamon Kabata
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan.
| | - Yoshitomo Kajino
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Takuro Ueno
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Ken Ueoka
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Yuki Yamamuro
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Hiroyuki Tsuchiya
- Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| |
Collapse
|
28
|
Lu Y, Xiao H, Xue F. Causes of and treatment options for dislocation following total hip arthroplasty. Exp Ther Med 2019; 18:1715-1722. [PMID: 31410129 PMCID: PMC6676097 DOI: 10.3892/etm.2019.7733] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 06/28/2019] [Indexed: 12/13/2022] Open
Abstract
The second most common complication following total hip arthroplasty (THA) is dislocation. The majority of dislocations occur early in the post-operative period and are due to either patient-associated or surgical factors. The patient-associated factors that have been implicated as causes of post-operative dislocation include previous surgery, lumbar spine fusion surgery and/or neurological impairment. The surgical factors include surgical approach, component orientation and prosthetic and/or bony impingement. In order to delineate the cause of the hip instability a thorough history and physical and a radiographic assessment (possibly including advanced imaging) needs to be performed. Approximately two thirds of cases are successfully treated; one third of cases will require surgical treatment (e.g., revision arthroplasty (including constrained liners, the use of elevated rim liners and dual mobility implants or trochanteric advancement). In this review, we discuss the causes leading to dislocation following THA and evaluate the different treatment options available.
Collapse
Affiliation(s)
- Yian Lu
- Department of Orthopedics, Fengxian Central Hospital, Shanghai 201400, P.R. China
| | - Haijun Xiao
- Department of Orthopedics, Fengxian Central Hospital, Shanghai 201400, P.R. China
| | - Feng Xue
- Department of Orthopedics, Fengxian Central Hospital, Shanghai 201400, P.R. China
| |
Collapse
|
29
|
Civinini R, Cozzi Lepri A, Carulli C, Matassi F, Villano M, Innocenti M. The anterior-based muscle-sparing approach to the hip: the "other" anterior approach to the hip. INTERNATIONAL ORTHOPAEDICS 2018; 43:47-53. [PMID: 30284607 DOI: 10.1007/s00264-018-4190-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 09/26/2018] [Indexed: 01/16/2023]
Abstract
PURPOSE The purpose of this study was to evaluate safety, efficacy, and learning curves of anterior-based muscle-sparing total hip arthroplasty (ABMS-THA) in the supine position. Furthermore, early functional outcome was evaluated and compared to direct anterior approach (DAA) by measuring surface electromyography (sEMG). METHODS We present a prospective cohort study of 343 hips. The safety and learning curve were assessed by recording operative time and peri-operative adverse events. For assessment of efficacy, functional and radiological outcomes were evaluated. A selected group of 32 patients have been studied by sEMG and compared to a matched group of 32 patients who received a THA using DAA approach. RESULTS There was one dislocation (0.3%); two (0.6%) patients had an intra-operative fractures of the greater trochanter; two patients (0.6%) experienced a self-limited femoral nerve palsy. Physical therapy milestones for hospital discharge were reached on an average of 1.7 days. sEMG showed that ABMS and DAA have a similar muscle recruitment pattern and functional recovery after THA. One patient was revised for infection, 16 were lost, and 326 hips were available with a median follow-up of 42 months (range 24-60). The mean Harris Hip Score (HSS) increased from 44.3 to 91.9. Ninety-six percent of the hips had a leg length discrepancy (LLD) < 5 mm. There were no radiological signs of mechanical loosening or osteolysis. CONCLUSIONS The ABMS approach in the supine position is clinically effective and safe; special advantages include a very low dislocation rate and a great control of LLD.
Collapse
Affiliation(s)
- Roberto Civinini
- Orthopaedic Clinic, Department of Surgery and Translational Medicine, University of Florence, C.T.O. Largo Palagi 1, 50139, Florence, Italy.
| | - Andrea Cozzi Lepri
- Orthopaedic Clinic, Department of Surgery and Translational Medicine, University of Florence, C.T.O. Largo Palagi 1, 50139, Florence, Italy
| | - Christian Carulli
- Orthopaedic Clinic, Department of Surgery and Translational Medicine, University of Florence, C.T.O. Largo Palagi 1, 50139, Florence, Italy
| | - Fabrizio Matassi
- Orthopaedic Clinic, Department of Surgery and Translational Medicine, University of Florence, C.T.O. Largo Palagi 1, 50139, Florence, Italy
| | - Marco Villano
- Orthopaedic Clinic, Department of Surgery and Translational Medicine, University of Florence, C.T.O. Largo Palagi 1, 50139, Florence, Italy
| | - Massimo Innocenti
- Orthopaedic Clinic, Department of Surgery and Translational Medicine, University of Florence, C.T.O. Largo Palagi 1, 50139, Florence, Italy
| |
Collapse
|
30
|
Zhao CC, Qu GX, Yan SG, Cai XZ. Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review. J Orthop Surg Res 2018; 13:133. [PMID: 29859126 PMCID: PMC5984797 DOI: 10.1186/s13018-018-0841-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 05/21/2018] [Indexed: 02/06/2023] Open
Abstract
Background Postoperative squeaking in patients who applied the fourth-generation ceramic bearing in primary hip replacement has not been reported systematically; we aim to study the squeaking incidence in the fourth-generation ceramic bearing and related risk factors for squeaking, and we also attempt to explore the relationship between squeaking and prosthetic brands. Methods The PubMed, Embase, and Cochrane library were searched, and 14 articles were finally included. Patients’ demographic data, surgical-related information, and prosthesis data were extracted. The occurrence rate of squeaking was calculated by meta-analysis, and subgroup analysis was performed based on prosthetic brands and follow-up time. Regression analysis was further applied to investigate the relationship between various risk factors and squeaking. Results The squeaking incidence in patients with the fourth-generation ceramic bearing was 3%. Age, gender, body mass index, and abduction and anteversion angles of acetabular cup might have no influence on squeaking. The squeaking incidence was significantly high with the presence of Delta Motion cup (DePuy, Warsaw, Indiana) and Secure-Fit stem (Stryker, Kalamazoo, MI), and the overall incidence of DePuy femoral stem was relatively small except for the Summit femoral stem. And there was no significant difference of squeaking incidence between less than 5-year and more than or equal to 5-year follow-up subgroups. Conclusions In our study, squeaking in the fourth-generation ceramic bearing occurred at a rate of 3%; occurrence rate was high when the Delta Motion cup was applied. We hope for more relevant researches to focus on this issue. Electronic supplementary material The online version of this article (10.1186/s13018-018-0841-y) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Chen-Chen Zhao
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China.,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China
| | - Guo-Xin Qu
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China.,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China
| | - Shi-Gui Yan
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China.,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China
| | - Xun-Zi Cai
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China. .,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China.
| |
Collapse
|
31
|
Caton JH, Ferreira A. Dual-mobility cup: a new French revolution. INTERNATIONAL ORTHOPAEDICS 2017; 41:433-437. [PMID: 28197702 DOI: 10.1007/s00264-017-3420-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Accepted: 01/26/2017] [Indexed: 01/16/2023]
Affiliation(s)
| | - André Ferreira
- Clinique du Parc, 155 Ter Boulevard de Stalingrad, 69006, Lyon, France.
| |
Collapse
|