1
|
Zhang X, Chen M, Zhang T, Zhang H, Yang B, Zhu C. Incidence and characteristics of noise generation in total hip arthroplasty with ceramic-on-ceramic bearings : a comparison between robotic-assisted surgery and conventional methods. Bone Joint J 2025; 107-B:391-403. [PMID: 40164185 DOI: 10.1302/0301-620x.107b4.bjj-2024-0506.r2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/02/2025]
Abstract
Aims To evaluate the impact and risk factors of robotic-assisted surgery (RAS) on noise generation in total hip arthroplasty (THA) with ceramic-on-ceramic (CoC) bearings in comparison to conventional (CON) manual methods. Methods A secondary analysis of a prospective multicentre randomized controlled trial - conducted from June 2021 to July 2022 - included 74 patients with CoC bearings, equally divided between RAS and CON groups. Noise incidence, characteristics, and duration were documented. Radiological assessments and logistic regression analysis were performed to identify predictors of noise or squeaking. Results The incidence of overall noise complaints was higher in the CON group compared to the RAS group, with a statistically significant difference observed at the early postoperative stage. Specifically, at 14 days post-surgery, 5.4% of patients in the RAS group and 32.4% in the CON group reported noises (p = 0.008), while at 24 weeks, the rates were 5.4% and 21.6%, respectively, with no statistically significant difference (p = 0.089). RAS showed superior alignment and precision in component placement. Logistic regression analysis identified conventional surgery as a significant predictor of noise complaints (odds ratio 7.10 (95% CI 1.51 to 33.33); p = 0.013). Additionally, the probability distributions of different acetabular alignment and abduction angles were plotted and analyzed. No differences in functional status or patient-reported outcomes were found between groups. Conclusion RAS in THA with CoC bearings reduces the incidence and severity of noise-related complications, and is likely due to more precise and appropriate component placement, which may improve outcomes.
Collapse
Affiliation(s)
- Xianzuo Zhang
- Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
| | - Mo Chen
- Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
| | - Tao Zhang
- Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
| | - Haining Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Bo Yang
- Department of Joint Surgery, Weifang People's Hospital, Weifang, China
| | - Chen Zhu
- Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
| |
Collapse
|
2
|
Kaneta H, Shoji T, Ueki S, Morita H, Kozuma Y, Adachi N. Evaluation of cup placement accuracy in computer assisted total hip arthroplasty. Arch Orthop Trauma Surg 2025; 145:191. [PMID: 40085242 PMCID: PMC11909047 DOI: 10.1007/s00402-025-05797-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2024] [Accepted: 02/28/2025] [Indexed: 03/16/2025]
Abstract
BACKGROUND Total hip arthroplasty (THA) accuracy has improved significantly with various advances in computer-assisted equipment (CAE), including robotic systems, computed tomography (CT) navigation, and portable navigation. However, no studies have directly compared the accuracy of acetabular cup placement and its impact on patient-reported outcome measures (PROMs) across these three CAE systems. In this study, we aimed to evaluate cup placement accuracy and PROMs in THA using different CAE systems. METHODS This retrospective analysis included 196 patients (202 hip joints) who underwent THA with three CAE systems from May 2021 to August 2023. Patients were categorized into the robotic system (73 hips), CT navigation (83 hips), and portable navigation (46 hips). Postoperative CT scans measured cup placement angles-radiographic inclination (RI) and radiographic anteversion (RA) -and compared them with preoperative target angles. Anterior-posterior (AP) cup position differences were evaluated by measuring the distance between the acetabular and cup center in the axial view of the postoperative CT scans. PROMs were evaluated using the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) at 3 and 12 months. RESULTS Demographic characteristics, including age, sex, primary disease, and Body Mass Index, were similar across groups. The robotic system exhibited significantly smaller deviations in ΔRI and ΔRA compared to CT navigation and portable navigation. AP cup position differences were also smaller in the robotic system versus portable navigation; however, the difference between the robotic and CT navigation systems was not statistically significant. Despite the superior precision of cup placement in the robotic system, no significant differences in JHEQ scores were observed among the groups at 3 and 12 months. CONCLUSION Robotic systems demonstrated superior accuracy in cup placement. However, short-term PROMs did not significantly differ, suggesting that PROMs may not solely depend on accurate cup placement. Future research should investigate additional factors influencing PROMs.
Collapse
Affiliation(s)
- Hiroki Kaneta
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
| | - Takeshi Shoji
- Department of Artificial Joints and Biomaterials, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
| | - Shinichi Ueki
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Hiroyuki Morita
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Yosuke Kozuma
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Nobuo Adachi
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
3
|
Shimizu A, Murakami S, Tamai T, Haga Y, Kutsuna T, Kinoshita T, Takao M. Comparing cup placement, leg length, and offset discrepancy after total hip arthroplasty between CT-based robotic arm-assisted and navigation systems. Bone Jt Open 2025; 6:3-11. [PMID: 39740687 PMCID: PMC11688127 DOI: 10.1302/2633-1462.61.bjo-2024-0173.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2025] Open
Abstract
Aims Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system. Methods We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan. After propensity score matching, each group had 37 hips. Postoperative acetabular component position and orientation were measured using the planning module of the CT-based navigation system. Postoperative leg length and offset discrepancies were evaluated using postoperative CT in patients who have unilateral hip osteoarthritis. Results The absolute differences in radiological inclination (RI) and radiological anteversion (RA) from the target were significantly smaller in rTHA (RI 1.2° (SD 1.2°), RA 1.4° (SD 1.2°)) than in nTHA (RI 2.7° (SD 1.9°), RA 3.0° (SD 2.6°)) (p = 0.005 for RI, p = 0.002 for RA). The absolute distance of the target's postoperative centre of rotation was significantly smaller in the mediolateral (ML) and superoinferior (SI) directions in rTHA (ML 1.1 mm (SD 0.8), SI 1.3 mm (SD 0.5)) than in nTHA (ML 1.9 mm (SD 0.9), SI 1.6 mm (SD 0.9)) (p = 0.002 for ML, p = 0.042 for SI). Absolute leg length and absolute discrepancies in the acetabular, femoral, and global offsets were significantly lower in the rTHA group than in the nTHA group (p = 0.042, p = 0.004, p = 0.003, and p = 0.010, respectively). In addition, the percentage of hips significantly differed with an absolute global offset discrepancy of ≤ 5 mm (p < 0.001). Conclusion rTHA is more accurate in cup orientation and position than nTHA, effectively reducing postoperative leg length and offset discrepancy.
Collapse
Affiliation(s)
- Akira Shimizu
- Department of Orthopedic Surgery, Ozu Memorial Hospital, Ozu, Japan
| | - Satoshi Murakami
- Department of Orthopedic Surgery, Ozu Memorial Hospital, Ozu, Japan
| | - Takayuki Tamai
- Department of Orthopedic Surgery, Ozu Memorial Hospital, Ozu, Japan
| | - Yuuki Haga
- Department of Orthopedic Surgery, Ozu Memorial Hospital, Ozu, Japan
| | - Tatsuhiko Kutsuna
- Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan
| | - Tomofumi Kinoshita
- Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan
| | - Masaki Takao
- Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan
| |
Collapse
|
4
|
Llombart-Blanco R, Mariscal G, Barrios C, Vera P, Llombart-Ais R. MAKO robot-assisted total hip arthroplasty: a comprehensive meta-analysis of efficacy and safety outcomes. J Orthop Surg Res 2024; 19:698. [PMID: 39468678 PMCID: PMC11520809 DOI: 10.1186/s13018-024-05199-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Accepted: 10/21/2024] [Indexed: 10/30/2024] Open
Abstract
BACKGROUND Introduction: Robotic surgery in total hip arthroplasty (THA) has emerged as a promising approach for improving precision and reducing errors. This meta-analysis aimed to compare the efficacy and safety of robot-assisted MAKO total hip arthroplasty. METHODS Studies were searched using four databases. Meta-analysis was performed using Review Manager 5.4. Efficacy was assessed radiologically, and functional scores and complications were recorded. RESULTS Twelve studies (1224 hips) were analyzed. The MAKO group achieved greater cup anteversion (MD 1.53, 95%CI 1.04-2.03) and a higher percentage of components within safe inclination and anteversion ranges (p > 0.05). Harris Hip Scores did not differ significantly (MD 0.61, 95%CI -0.22-1.45) but the forgotten joint scores favored MAKO (MD 5.99, 95% CI 4.10-7.88), although not exceeding the minimally clinically significant difference. No differences in intraoperative complications emerged (OR 0.96, 95%CI 0.51-1.79) but preoperative plans significantly mismatched the final cup placement after MAKO (p < 0.05). CONCLUSIONS The use of the MAKO robot in THA improves radiological outcomes by enhancing safe prosthesis placement. However, no significant differences were observed in terms of complications. Longer follow-up studies are required to assess the clinical impact of improved radiological results. LEVEL OF EVIDENCE Level IV metaanalysis of nonrandomized clinical trials. REGISTRATION CRD42023433733.
Collapse
Affiliation(s)
| | - Gonzalo Mariscal
- Institute for Research on Musculoskeletal Disorders, School of Medicine, Catholic University of Valencia, Carrer de Quevedo, 2, Valencia, 46001, Spain.
| | - Carlos Barrios
- Institute for Research on Musculoskeletal Disorders, School of Medicine, Catholic University of Valencia, Carrer de Quevedo, 2, Valencia, 46001, Spain
| | - Pablo Vera
- Institute for Research on Musculoskeletal Disorders, School of Medicine, Catholic University of Valencia, Carrer de Quevedo, 2, Valencia, 46001, Spain
| | - Rafael Llombart-Ais
- Institute for Research on Musculoskeletal Disorders, School of Medicine, Catholic University of Valencia, Carrer de Quevedo, 2, Valencia, 46001, Spain
- Traumacenter, La Salud Hospital, Valencia, Spain
| |
Collapse
|
5
|
Yu C, Zhang Z, Liu C, Huang Z, Lu X, Gao Y, Zhang H. Robotic-assisted total hip arthroplasty outperforms manual technique in obese and overweight patients: a prospective comparative study. J Orthop Surg Res 2024; 19:639. [PMID: 39380017 PMCID: PMC11463081 DOI: 10.1186/s13018-024-05117-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Accepted: 09/25/2024] [Indexed: 10/10/2024] Open
Abstract
BACKGROUND With the increasing prevalence of obesity, there is growing awareness of the impact of overweight and obesity on total hip arthroplasty (THA). Research exploring the accuracy of acetabular component orientation in THA between robotic-assisted and manual techniques across different BMI categories is insufficient. METHODS This prospective study evaluated 221 patients who underwent THA with a Robotic Interactive Orthopaedic Arm system and 252 patients who underwent manual THA between March 2022 and January 2024. The patients were divided into four groups according to their BMI. We analysed whether there were differences in the accuracy of acetabular component positioning between robotic-assisted THA and manual THA across different BMI categories. RESULTS In the overweight group, robotic-assisted THA achieved a significantly higher rate of abductions within the target range (73/6) than manual THA (62/28) (p = 0.000). Both abductions and anteversions within the target range were also significantly more frequent in the robotic-assisted THA group (69/10) than in the manual THA group (56/34) (p = 0.000). Among the obese patients, robotic-assisted THA showed a perfect record for anteversions within the target range (29/0), markedly outperforming manual THA (39/6) (p = 0.040). CONCLUSION In the overweight (24 kg/m² ≤ BMI < 28 kg/m²) and obese (BMI ≥ 28 kg/m²) groups, robotic-assisted THA demonstrates significantly greater accuracy in acetabular component positioning compared to manual THA. This indicates that robotic-assisted technology may provide a more precise positioning of the acetabular component in overweight and obese patients.
Collapse
Affiliation(s)
- Chaoqun Yu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China
| | - Zian Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China
| | - Chang Liu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China
| | - Zhenchao Huang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China
| | - Xinzhe Lu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China
| | - Yusi Gao
- Operating Room, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China
| | - Haining Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, China.
| |
Collapse
|
6
|
Okazaki T, Imagama T, Matsuki Y, Tanaka H, Shiigi E, Kaneoka T, Kawakami T, Yamazaki K, Sakai T. Accuracy of robotic arm-assisted versus computed tomography-based navigation in total hip arthroplasty using the direct anterior approach: a retrospective study. BMC Musculoskelet Disord 2024; 25:787. [PMID: 39367310 PMCID: PMC11451141 DOI: 10.1186/s12891-024-07891-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 09/23/2024] [Indexed: 10/06/2024] Open
Abstract
BACKGROUND A robotic arm-assisted and a computed tomography (CT)- based navigation system have been reported to improve the accuracy of component positioning in total hip arthroplasty (THA). However, no study has compared robotic arm-assisted THA (rTHA) to CT-based navigated THA (nTHA) concerning accuracy of cup placement and acetabular fractures using the direct anterior approach (DAA). This study aimed to compare the accuracy of cup placement and the presence of intraoperative acetabular fractures between rTHA and nTHA using DAA in the supine position. METHODS We retrospectively investigated 209 hips of 188 patients who underwent rTHA or nTHA using DAA (rTHA using the Mako system: 85 hips of 79 patients; nTHA: 124 hips of 109 patients). After propensity score matching for age and sex, each group consisted of 73 hips. We evaluated clinical and radiographic outcomes, comparing postoperative cup orientation and position, measured using a three-dimensional templating software, to preoperative CT planning. Additionally, we investigated the prevalence of occult acetabular fracture. RESULTS Clinical outcomes were not significantly different between the groups at 1 year postoperatively. The mean absolute error of cup orientation was significantly smaller in the rTHA group than in nTHA (inclination: 1.4° ± 1.2° vs. 2.7° ± 2.2°, respectively; p = 0.0001, anteversion: 1.5° ± 1.3° vs. 2.2° ± 1.7°, respectively; p = 0.007). The cases within an absolute error of 5 degrees in both RI and RA were significantly higher in the rTHA (97.3%) than in nTHA group (82.2%) (p = 0.003). The absolute error of the cup position was not significantly different between the two groups. The prevalence of occult acetabular fracture did not differ significantly between the two groups (rTHA: n = 0 [0%] vs. nTHA: n = 1 [1.4%]). CONCLUSION Cup placement using DAA in the supine position in rTHA was more accurate with fewer outliers compared to nTHA. Therefore, rTHA performed via DAA in a supine position would be useful for accurate cup placement.
Collapse
Affiliation(s)
- Tomoya Okazaki
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan.
- Department of Orthopedic Surgery, Yamaguchi Prefectural Grand Medical Center, Hofu, Yamaguchi, 747-8511, Japan.
| | - Takashi Imagama
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan
| | - Yuta Matsuki
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan
- Department of Orthopedic Surgery, Yamaguchi Prefectural Grand Medical Center, Hofu, Yamaguchi, 747-8511, Japan
| | - Hiroshi Tanaka
- Department of Orthopedic Surgery, Yamaguchi Prefectural Grand Medical Center, Hofu, Yamaguchi, 747-8511, Japan
| | - Eiichi Shiigi
- Department of Orthopedic Surgery, Yamaguchi Prefectural Grand Medical Center, Hofu, Yamaguchi, 747-8511, Japan
| | - Takehiro Kaneoka
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan
| | - Takehiro Kawakami
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan
| | - Kazuhiro Yamazaki
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan
| | - Takashi Sakai
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, 755-8505, Japan
| |
Collapse
|
7
|
Kokubu Y, Kawahara S, Ayabe Y, Motomura G, Hamai S, Hara T, Nakashima Y. Evaluation of Leg Length Difference on Perioperative Radiographs of Total Hip Arthroplasty Considering Lower Limb Malposition. Cureus 2024; 16:e70790. [PMID: 39493174 PMCID: PMC11531339 DOI: 10.7759/cureus.70790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/03/2024] [Indexed: 11/05/2024] Open
Abstract
BACKGROUND During total hip arthroplasty (THA) in lateral decubitus, perioperative radiography allows the surgeon a simple evaluation of the leg length difference (LLD) by measuring the proximal femoral length. However, the effect of femoral malpositioning on proximal femoral length measurements during the evaluation of perioperative radiographs is not adequately understood. We aimed to (1) investigate the effects of malposition on proximal femoral length using three-dimensional computer simulations and (2) verify whether a simple correction formula can improve the accuracy of LLD evaluation on perioperative radiographs. METHODS We analyzed 86 patients who underwent THA. Digitally reconstructed radiography (DRR) images were reconstructed in various limb positions (femoral abduction, adduction, and flexion), and proximal femoral length measurements in those malpositions were simulated. Additional morphological measurements of the femoral neck torsion angle in the sagittal plane were performed to elucidate the simulation findings. The malposition angle of abduction-adduction was evaluated with actual perioperative radiographs, and trigonometric correction was attempted. RESULTS The leg length measurement decreased as the femoral DRR image shifted from neutral to abduction and adduction, demonstrating approximately 1 mm per 10° of abduction or adduction. The leg length measurement increased as the femoral image shifted from neutral to 10° and 20° of flexion, demonstrating approximately 3 mm per 10° of flexion. With a peak at 20° of flexion, the proximal femoral length measurement decreased in the DRR images at 30°, 40°, 50° and 60° of flexion. The femoral neck torsion angle was 21.1 ± 5.6° on the operative side. The effect of coronal malposition on leg length discrepancy was so small that the difference following trigonometric correction was not statistically significant (p=0.108). CONCLUSION In the present simulation, coronal malposition had a small effect on LLD evaluation. As the femoral neck has a torsion of approximately 20°, the proximal femoral length is projected the longest when the femur is flexed 20°. With careful positioning of the limb in the coronal plane, the use of a correction formula for LLD evaluation would not be necessary. Surgeons should ensure that both lower limbs are in the same position in the sagittal plane during THA in lateral decubitus.
Collapse
Affiliation(s)
- Yasuhiko Kokubu
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
| | - Shinya Kawahara
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
| | - Yusuke Ayabe
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
| | - Goro Motomura
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
| | - Satoshi Hamai
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
| | - Toshihiko Hara
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
- Department of Orthopedic Surgery, Aso-Iizuka Hospital, Iizuka, JPN
| | - Yasuharu Nakashima
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN
| |
Collapse
|
8
|
Ueno M, Kawano S, Fujii M, Tanaka S, Sakumo K, Morimoto T. Does Preoperative Virtual Reality Experience Enhance Implant Positioning Accuracy in Total Hip Arthroplasty? Cureus 2024; 16:e70390. [PMID: 39469377 PMCID: PMC11516148 DOI: 10.7759/cureus.70390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/26/2024] [Indexed: 10/30/2024] Open
Abstract
Purpose Total hip arthroplasty (THA) requires precise implant positioning to ensure long-term success. Herein, we evaluated the effect of virtual reality (VR) on the surgical precision of THA, particularly when used by experienced surgeons. Methods In this single-center, prospective, case-control study, 34 patients who underwent primary THA performed by a single experienced surgeon were divided into the control (without VR simulation) and VR (with VR simulation) groups. Preoperative planning involved the creation of three-dimensional models from computed tomography scans using ZedHip® software (Lexi, Tokyo, Japan). The primary outcomes assessed included the accuracy of implant placement, operative time, and intraoperative blood loss. The secondary outcomes included postoperative hospital stay and in-hospital complications. Results A significant improvement in radiographic inclination (RI) was observed in the VR group as compared to controls. Other surgical parameters, such as radiographic anteversion, operation time, blood loss, and postoperative hospital stay, showed no significant differences between the groups. Discrepancies in planned versus actual implant sizes were noted but were not significantly different between groups. Conclusion VR application in preoperative planning improved the RI accuracy in acetabular cup placement for THA, demonstrating its potential to enhance surgical precision for experienced surgeons. This study highlights the evolving role of VR, from a training tool to an integral part of advanced surgical planning in orthopedics.
Collapse
Affiliation(s)
- Masaya Ueno
- Orthopaedic Surgery, Saga University, Saga, JPN
| | | | | | | | - Kii Sakumo
- Orthopaedic Surgery, Saga University, Saga, JPN
| | | |
Collapse
|
9
|
An HM, Cao Z, Zhang S, Yang MZ, Kong XP, Chai W. Why robot-assisted total hip arthroplasty aborted: Chinese experience of four hundred and twenty nine consecutive cases. INTERNATIONAL ORTHOPAEDICS 2024; 48:2359-2365. [PMID: 39012414 DOI: 10.1007/s00264-024-06250-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 07/02/2024] [Indexed: 07/17/2024]
Abstract
PURPOSE Robot-assisted total hip arthroplasty (RA-THA) helps with precise orientation of the prosthesis, but some RA-THA procedures are aborted intraoperatively and are converted to manual total hip arthroplasty (THA). This study aimed to analyse why RA-THA is sometimes aborted intraoperatively and to make recommendations accordingly. METHODS A total of 429 consecutive Mako THA cases in our prospective database from August 2018 to June 2021 were included in our study. All robotic procedures aborted intraoperatively for any reason were recorded. The patients' demographics, diagnoses, and surgeons' information were included in the statistical analysis to pinpoint the risk factors for intraoperative robot to manual conversion. RESULTS Intraoperative RA-THA abortions occurred in 17 cases (3.96%) and the patients had to be converted to manual THA. The adverse events leading to intraoperative abortions included pelvic array loosening or malposition (5, 1.17%), inaccurate bone mapping or construction (6, 1.40%), inaccurate initial registration (4, 0.93%), and other reasons (2, 0.47%). CONCLUSION Robot-related adverse events could be found in all perioperative steps of RA-THA, and some of these events might result in intraoperative abortion. Complex hip disease was a statistically significant factor for an increased risk of intraoperative abortion of RA-THA. Standardized surgical procedures and preoperative assessments can be helpful in reducing the rate of RA-THA abortions.
Collapse
Affiliation(s)
- Hao-Ming An
- School of Medicine, Nankai University, Tianjin, China
- Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China
- Chinese PLA Medical School, Beijing, China
| | - Zheng Cao
- School of Medicine, Nankai University, Tianjin, China
- Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China
- Chinese PLA Medical School, Beijing, China
| | - Shuai Zhang
- Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China
- Chinese PLA Medical School, Beijing, China
- Department of Orthopedics, 969th Hospital of Joint Logistics Support Force of PLA, Hohhot, 010051, China
| | - Min-Zhi Yang
- Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China
- Chinese PLA Medical School, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China
| | - Xiang-Peng Kong
- Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China.
| | - Wei Chai
- Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China.
| |
Collapse
|
10
|
Konishi T, Sato T, Hamai S, Kawahara S, Hara D, Nakashima Y. Robotic Arm-Assisted System Improved Accuracy of Cup Position and Orientation in Cementless Total Hip Arthroplasty for Dysplastic Hips: A Comparison Among Groups With Manual Placement, Computed Tomography-Based Navigation, and Robotic Surgery. Arthroplast Today 2024; 28:101461. [PMID: 39100425 PMCID: PMC11295473 DOI: 10.1016/j.artd.2024.101461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 04/05/2024] [Accepted: 06/09/2024] [Indexed: 08/06/2024] Open
Abstract
Background Accurate cup placement in total hip arthroplasty (THA) for patients with dysplasia is challenging due to the distinctive bone deformities. This study aimed to compare the accuracy of cup placement position and orientation across robotic arm-assisted systems (R-THA), computed tomography-based navigation (N-THA), and manual procedure (M-THA) in THA for osteoarthritis secondary to dysplasia. Methods A total of 167 patients (197 hips), including 88 R-THAs, 45 N-THAs, and 46 M-THAs, were analyzed. Propensity score matching was performed to align the patient backgrounds. Horizontal and vertical centers of rotation were measured for cup position, whereas radiographic inclination and anteversion were measured for cup orientation. The proportion of cases with cup placement within 3 mm and 5° from the target was compared. Results R-THA had a significantly higher percentage of cup placement within 3 mm of the target compared to N-THA (78% vs 49%; P = .0041) and M-THA (78% vs 53%; P = .013). Similarly, R-THA was significantly more successful in placing the cup within 5° of the target compared to N-THA (84% vs 58%; P = .0049) and M-THA (91% vs 20%; P < .0001). Moreover, N-THA was significantly better at placing the cup within 5° of the target compared to M-THA (62% vs 14%; P < .0001), whereas there was no significant difference in the percentage of cup placement within 3 mm of the target (51% vs 51%; P = 1.0). Conclusions Robotic arm-assisted system and computed tomography-based navigation improved accuracy in cup orientation compared to the manual procedure. Additionally, the robotic arm-assisted system further improved cup position accuracy.
Collapse
Affiliation(s)
- Toshiki Konishi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Taishi Sato
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Shinya Kawahara
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Daisuke Hara
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
11
|
Vorimore C, Verhaegen JCF, Innmann M, Monk AP, Ling C, Grammatopoulos G. Change in cup orientation from supine to standing posture: a prospective cohort study of 419 total hip arthroplasties. Acta Orthop 2024; 95:425-432. [PMID: 39037005 PMCID: PMC11261814 DOI: 10.2340/17453674.2024.41091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 06/23/2024] [Indexed: 07/23/2024] Open
Abstract
BACKGROUND AND PURPOSE Arthroplasty surgeons traditionally assess cup orientation after total hip arthroplasty (THA) on supine radiographs. Contemporary hip-spine analyses provide information on standing, functional cup orientation. This study aims to (i) characterize cup orientations when supine and standing; (ii) determine orientation differences between postures; and (iii) identify factors associated with magnitude of orientation differences. METHODS This is a 2-center, multi-surgeon, prospective, consecutive cohort study. 419 primary THAs were included (57% women; mean age: 64 years, standard deviation [SD] 11). All patients underwent supine and standing antero-posterior pelvic and lateral spinopelvic radiographs. Cup orientation and spinopelvic parameters were measured. Target cup orientation was defined as inclination/anteversion of 40°/20° ± 10°. A change in orientation (Δinclination/Δanteversion) between postures > 5° was defined as clinically significant. Variability was defined as 2 x SD. RESULTS Inclination increased from 40° (supine) to 42° (standing) corresponding to a Δinclination of 2° (95% confidence interval [CI] 2-3). Anteversion increased from 25° (supine) to 30° (standing) corresponding to a Δanteversion of 5° (CI 5-6). When supine, 69% (CI 65-74) of THAs were within target, but only 44% (CI 39-49) were within target when standing, resulting in a further 26% (CI 21-30) being out of target when standing. From supine to standing, a clinically significant change in anteversion (> 5°) was seen in 47% (CI 42-52) of cases. Δanteversion was higher in women than in men (6°, CI 5-7 vs 5°, CI 4-5) corresponding to a difference of 1° (CI 1-2), which was dependent on tilt change, standing cup anteversion, age, and standing pelvic tilt. CONCLUSION Cup inclination and version increase upon standing but significant variability exists due to patient factors.
Collapse
Affiliation(s)
- Camille Vorimore
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
| | - Jeroen C F Verhaegen
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; University Hospital Antwerp, Edegem, Belgium; Orthopaedic Centre Antwerp, AZ Monica, Antwerp, Belgium
| | - Moritz Innmann
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; Heidelberg University, Heidelberg, Germany
| | - A Paul Monk
- Auckland Surgical Centre, Auckland, New Zealand
| | | | | |
Collapse
|
12
|
Crone TP, Cornelissen BMW, Van Oldenrijk J, Bos PK, Veltman ES. Intraoperative application of three-dimensional printed guides in total hip arthroplasty: A systematic review. World J Orthop 2024; 15:660-667. [PMID: 39070940 PMCID: PMC11271698 DOI: 10.5312/wjo.v15.i7.660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/23/2024] [Accepted: 06/24/2024] [Indexed: 07/12/2024] Open
Abstract
BACKGROUND Acetabular component positioning in total hip arthroplasty (THA) is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications. The majority of acetabular components are aligned freehand, without the use of navigation methods. Patient specific instruments (PSI) and three-dimensional (3D) printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning. AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment. METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA. Eight studies with 236 hips in 228 patients were included. The studies could be divided into two main categories; 3D printed models and 3D printed guides. RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups (P = 0.019, P = 0.009). Otherwise, outcome measures were heterogeneous and thus difficult to compare. The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs. CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning.
Collapse
Affiliation(s)
- Tim P Crone
- Department of Orthopedic Surgery and Sports Medicine, Erasmus Medical Center, Rotterdam 3015 GD, Netherlands
| | - Bart M W Cornelissen
- Department of Oral and Maxillofacial Surgery, Erasmus Medical Center, Rotterdam 3015 GD, Netherlands
| | - Jakob Van Oldenrijk
- Department of Orthopedic Surgery and Sports Medicine, Erasmus Medical Center, Rotterdam 3015 GD, Netherlands
| | - Pieter Koen Bos
- Department of Orthopedic Surgery and Sports Medicine, Erasmus Medical Center, Rotterdam 3015 GD, Netherlands
| | - Ewout S Veltman
- Department of Orthopedic Surgery and Sports Medicine, Erasmus Medical Center, Rotterdam 3015 GD, Netherlands
| |
Collapse
|
13
|
Hecht CJ, Nedder VJ, Porto JR, Morgan KA, Kamath AF. Are robotic-assisted and computer-navigated total hip arthroplasty associated with superior outcomes in patients who have hip dysplasia? J Orthop 2024; 53:125-132. [PMID: 38515529 PMCID: PMC10950562 DOI: 10.1016/j.jor.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 03/03/2024] [Accepted: 03/06/2024] [Indexed: 03/23/2024] Open
Abstract
Introduction Robotic-assisted (RA) and computer-navigated (CN) total hip arthroplasty (THA) have been demonstrated to improve component placement accuracy compared to manual THA (mTHA) for primary osteoarthritis. As hip dysplasia presents several additional challenges in component placement accuracy and leg length discrepancy (LLD) correction during THA, a systematic review was conducted to evaluate whether utilizing these platforms may be associated with superior outcomes over mTHA in patients who have hip dysplasia. Methods PubMed, Medline, EBSCOhost, and Google Scholar were searched on September 13, 2023 to identify comparative studies published after January 1, 2000 that evaluated outcomes of RA-THA or CN-THA in patients who have hip dysplasia. The query yielded 197 unique articles, which were screened for alignment with the study aims. After screening, 10 studies fulfilled all inclusion criteria, comprising 946 patients. Risk of bias was evaluated via the Methodological Index for Nonrandomized Studies tool, and the mean score was 21.2 ± 1.5. Results Both RA-THA and CN-THA were not associated with improved acetabular anteversion and inclination when evaluating Crowe I-IV types altogether compared to mTHA, but studies reported improved accuracy for each Crowe I and II cases when assessed individually. While studies reporting acetabular cup placement within the Lewinnek and Callanan safe zones consistently found higher odds of accurate positioning for RA-THA versus mTHA, accuracy in achieving targeted center of rotation was mixed. Also, studies reported no difference in LLD restoration for RA-THA and CN-THA compared to mTHA. While operative time may be increased when utilizing these platforms, they may also expedite specific sequences, offsetting most of the increase in operative time. Conclusion This review highlights the advantages of RA-THA and CN-THA for patients who have DDH, particularly when treating Crowe I and II types as superior radiographic outcomes were achieved with these intraoperative technologies. However, there remains a need for studies to investigate whether this results in patient-reported outcome measures.
Collapse
Affiliation(s)
- Christian J. Hecht
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Victoria J. Nedder
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Joshua R. Porto
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Kerry A. Morgan
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Atul F. Kamath
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| |
Collapse
|
14
|
Tian R, Gao X, Kong N, Li X, Li Y, Wang J, Cao Y, Shi Z, Wang K, Yang P. A new seven-axis robotic-assisted total hip arthroplasty system improves component positioning: a prospective, randomized, multicenter study. Sci Rep 2024; 14:12643. [PMID: 38825602 PMCID: PMC11144703 DOI: 10.1038/s41598-024-63624-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 05/30/2024] [Indexed: 06/04/2024] Open
Abstract
This study compared the radiologic and clinical outcomes of a new seven-axis robotic-assisted total hip arthroplasty (THA) and conventional THA. Hundred and four patients were randomly assigned to two groups-the robotic-assisted THA group (RAS group) and the conventional THA group (CON group). The preoperative and postoperative Harris Hip score (HHS), acetabular inclination, anteversion, femoral offset, and leg length discrepancy (LLD) were compared. During the follow-up, no patients had any complications that could be associated with the use of the robot. The proportion of acetabular cups in the safety zone was significantly higher in the RAS group than that in the CON group. The two groups had significantly different mean absolute difference of inclination and anteversion. There was no significant difference in the postoperative HHSs, changes in HHSs, femoral offset, and lower limb length between the two groups. The seven-axis robotic-assisted THA system is safe and effective, and leads to better acetabulum cup positioning compared to conventional THA. The improvements observed in the HHS, LLD, and femoral offset in the RAS group were similar to those in the CON group.Clinical trial registration time: 19/05/2022.Clinical trial registration number: ChiCTR2200060115.
Collapse
Affiliation(s)
- Run Tian
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Xu Gao
- Xi'an Honghui Hospital, Xi'an, China
| | - Ning Kong
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Xinghua Li
- Department of Radiology, Xi'an Jiaotong University Second Affiliated Hospital, Xi'an, China
| | - Yiyang Li
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Jian Wang
- Department of Orthopedics, Southern Medical University Nanfang Hospital, Guangzhou, China
| | - Yongping Cao
- Department of Orthopedics, Peking University First Hospital, Beijing, China
| | - Zhanjun Shi
- Department of Orthopedics, Southern Medical University Nanfang Hospital, Guangzhou, China
| | - Kunzheng Wang
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Pei Yang
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China.
| |
Collapse
|
15
|
Dretakis K, Piagkou M, Koutserimpas C. Restoring Hip Joint Anatomy With the Robotic Arm-Assisted System in Hip Fractures: Expanding the Applications for Hip Surgery. Arthroplast Today 2024; 27:101381. [PMID: 38680847 PMCID: PMC11047285 DOI: 10.1016/j.artd.2024.101381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 03/13/2024] [Accepted: 03/17/2024] [Indexed: 05/01/2024] Open
Abstract
Total hip arthroplasty (THA) has improved the life quality of osteoarthritic patients, yet challenges persist. The robotic arm-assisted system, integrated into THA, aims to refine implant positioning, enhance precision, reduce errors, and restore the hip joint's anatomy, including hip center, femoral offset, and limb length. We present the first use of the system for the treatment of a subcapital femoral neck hip fracture. A 62-year-old female suffering a left subcapital hip fracture underwent THA using the robotic arm-assisted system. After acetabular registration, accurate component placement was achieved, and a 9-mm limb length discrepancy was addressed. The patient had an unremarkable recovery with a reported Harris hip score of 96.5 at 18 months postsurgery. Robotic-guided navigation in THA, as showcased in this case, ensures accurate implant positioning by restoring the anatomical features of the hip joint. Its potential extends beyond conventional applications, hinting at future use in trauma, revision, and oncology cases. While promising, future adaptations should consider soft tissue dynamics to ensure joint stability and overall success.
Collapse
Affiliation(s)
| | - Maria Piagkou
- Faculty of Health Sciences, Department of Anatomy, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
| | - Christos Koutserimpas
- Faculty of Health Sciences, Department of Anatomy, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
16
|
Zhang S, Ma M, Kong X, Zhou Y, Chen J, Chai W. Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip. INTERNATIONAL ORTHOPAEDICS 2024; 48:1189-1199. [PMID: 38358516 DOI: 10.1007/s00264-024-06115-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 01/31/2024] [Indexed: 02/16/2024]
Abstract
PURPOSES Due to the morphological diversity of deformities, technical difficulties, improperly designed components, and so on, THA remains a challenging task in dysplastic hips, especially in highly dislocated hips. The purpose of this study was to comprehensively evaluate the clinical outcomes of robot-assisted THA in patients with DDH through a large cohort study, including the precision of acetabular cup positioning, indicators of inflammatory response, indicators of muscle damage, and complications. METHODS We retrospectively analyzed patients with DDH who underwent THA in our prospectively constructed joint registry between August 2018 and August 2022. Finally, 147 manual THAs and 147 robotic-assisted THAs were included in the final analysis. Patient demographics, indicators of inflammation, indicators of muscle damage, operative time, Harris hip scores (HHS), and forgotten joint score (FJS) were recorded for analysis. The precision of the positioning of the acetabular component was assessed with plain radiographs. RESULTS In the Crowe II/III groups, the reconstructed center of rotation (COR) in the robotic-assisted group was closer to the anatomical COR with less variation than the manual group (absolute horizontal distances of COR 3.5 ± 2.8 vs. 5.4 ± 4.9 mm, p < 0.05; absolute vertical distances of COR 6.4 ± 4.1 vs. 11.7 ± 8.2 mm, p = 0.001). For all Crowe subtypes, the robotic-assisted THA significantly increased the proportion of acetabular cups located in the safety zone within 5° (all p < 0.05). Interleukin-6 and creatine kinase levels were slightly lower and significantly different in the robotic-assisted group at three days postoperatively (all p < 0.05). CONCLUSIONS Compared to the manual technique, the robot-assisted technique improved the precision and reproducibility of acetabular component positioning, particularly in DDH patients with Crowe types II/III. The robotic-assisted technique did not increase operative time, bleeding, complications, or revision rates, and had a slighter early inflammatory response and muscle damage.
Collapse
Affiliation(s)
- Shuai Zhang
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China
- Department of Orthopedics, the 969th Hospital of the PLA joint Logisitcs Support Force, No. 51 Aimin street, Xincheng District, Huhehaote, China
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China
| | - Mingyang Ma
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| | - Xiangpeng Kong
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China
| | - Yonggang Zhou
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| | - Jiying Chen
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| | - Wei Chai
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| |
Collapse
|
17
|
Naito Y, Hasegawa M, Tone S, Wakabayashi H, Sudo A. Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology. Arch Orthop Trauma Surg 2024; 144:2381-2389. [PMID: 38554208 DOI: 10.1007/s00402-024-05284-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 03/10/2024] [Indexed: 04/01/2024]
Abstract
INTRODUCTION This study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (THA) in the lateral decubitus position using a new computed tomography (CT)-based navigation system with augmented reality (AR) technology. MATERIALS AND METHODS There were 37 cementless THAs performed using a CT-based navigation system with AR technology in the lateral decubitus position and 63 cementless THAs performed using manual implant techniques in the lateral decubitus position in this retrospective study. Postoperative cup radiographic inclination and anteversion were measured using postoperative CT, and the proportion of hips within Lewinnek's safe zone was analyzed and compared between the two groups. The mean absolute values of navigation error were assessed. Intraoperative pelvic tilt angles were also recorded using navigation system. RESULTS The percentage of cups inside Lewinnek's safe zone was 100% in the navigation group and 35% in the control group (p < 0.001). The mean absolute values of navigation error in inclination and anteversion were 2.9° ± 2.1° and 3.3° ± 2.4°, respectively. The mean abduction angle of the pelvis was 5.1° ± 4.8° after placing the patients in the lateral decubitus position and 4.1° ± 6.0° after cup placement. The mean posterior tilt angle was 6.8° ± 5.1° after placing the patients in the lateral decubitus position and 9.3° ± 5.9° after cup placement. The mean internal rotation angle was 14.8° ± 7.4° after cup placement. There were no correlations between the navigation error in inclination or anteversion and the absolute values of changes of the pelvic tilt angle at any phase. CONCLUSIONS Although progressive pelvic motion occurred in THA in the lateral decubitus position, especially during cup placement, the CT-based navigation system with AR technology improved cup placement accuracy.
Collapse
Affiliation(s)
- Yohei Naito
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174, Edobashi, Tsu, Mie, 514-8507, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174, Edobashi, Tsu, Mie, 514-8507, Japan.
| | - Shine Tone
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174, Edobashi, Tsu, Mie, 514-8507, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174, Edobashi, Tsu, Mie, 514-8507, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174, Edobashi, Tsu, Mie, 514-8507, Japan
| |
Collapse
|
18
|
Tamaki Y, Goto T, Wada K, Omichi Y, Hamada D, Sairyo K. Robotic arm-assisted total hip arthroplasty via a minimally invasive anterolateral approach in the supine position improves the precision of cup placement in patients with developmental dysplasia of the hip. J Orthop Sci 2024; 29:559-565. [PMID: 36801090 DOI: 10.1016/j.jos.2023.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 12/02/2022] [Accepted: 01/31/2023] [Indexed: 02/23/2023]
Abstract
BACKGROUND This study evaluated the accuracy of the cup alignment angles and spatial cup positioning on computed tomography (CT) images in patients with osteoarthritis secondary to developmental dysplasia of the hip (DDH) who underwent total hip arthroplasty (THA) using a minimally invasive technique via an anterolateral approach in the supine position according to whether a robotic arm-assisted system or a CT-based navigation system was used. METHODS We reviewed 60 robotic arm-assisted (RA)-THA cases and 174 navigation-assisted (NA)-THA cases. After propensity score matching, there were 52 hips in each group. Postoperative cup alignment angles and position were assessed by superimposition of a three-dimensional cup template onto the actual implanted cup using postoperative CT images with pelvic coordinates matching the preoperative planning. RESULTS The mean absolute error of the inclination angle and the anteversion angle between the preoperative planning and the postoperative measurement was significantly smaller in the RA-THA group (inclination, 1.1° ± 0.9; anteversion, 1.3° ± 1.0) than in the NA-THA group (inclination, 2.2° ± 1.5; anteversion, 3.3° ± 2.5). For acetabular cup positioning, the mean discrepancy between the preoperative planning and the postoperative measurement was 1.3 ± 1.3 mm on the transverse axis, 2.0 ± 2.0 mm on the longitudinal axis, and 1.3 ± 1.7 mm on the sagittal axis in the RA-THA group and 1.6 ± 1.4 mm, 2.6 ± 2.3 mm, and 1.8 ± 1.3 mm, respectively, in the NA-THA group. High precision of cup positioning was observed in both groups with no statistically significant difference. CONCLUSION Robotic arm-assisted THA using a minimally invasive technique via an anterolateral approach in the supine position allows accurate cup placement in patients with DDH.
Collapse
Affiliation(s)
- Yasuaki Tamaki
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan
| | - Tomohiro Goto
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan.
| | - Keizo Wada
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan
| | - Yasuyuki Omichi
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan
| | - Daisuke Hamada
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan
| | - Koichi Sairyo
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan
| |
Collapse
|
19
|
Sugano N, Maeda Y, Fuji H, Tamura K, Nakamura N, Takashima K, Uemura K, Hamada H. Accuracy of femoral component anteversion in robotic total hip arthroplasty. Bone Joint J 2024; 106-B:104-109. [PMID: 38425294 DOI: 10.1302/0301-620x.106b3.bjj-2023-0840.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component.
Collapse
Affiliation(s)
- Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Yuki Maeda
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Haruka Fuji
- Orthopaedic Surgery, Kyowakai Hospital, Suita, Japan
| | | | | | - Kazuma Takashima
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Keisuke Uemura
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
20
|
Ma M, Cao Z, Yang M, Kong X, Chai W. The invasiveness of robot-assisted total hip replacement is similar to that of conventional surgery. J Robot Surg 2023; 17:2987-2993. [PMID: 37891384 DOI: 10.1007/s11701-023-01740-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/06/2023] [Indexed: 10/29/2023]
Abstract
Robot-assisted total hip arthroplasty (R-THA) is increasingly being performed throughout the world. The invasiveness of this operation is unknown. We retrospectively reviewed the cohort of consecutive osteonecrosis of the femoral head (ONFH) patients who received primary R-THA or manual THA (M-THA) from January 2020 to January 2022 in our institution. One experienced surgeon performed all procedures. We calculated the propensity score to match similar patients in different groups by multivariate logistic regression analysis for each patient. We included confounders consisting of age, sex, body mass index (BMI), and operation time. Preoperative serum markers and Harris hip scores (HHS), postoperative serum markers at first day and third day, complications rate, postoperative HHS and Forgotten Joint Score (FJS) at 6 months after surgery of different cohorts were compared. We analyzed 218 ONFH patients treated with THA (98 R-THA patients, and 120 M-THA patients). After propensity score matching, we generated cohorts of 95 patients in R-THA and M-THA groups. We found no significant difference in preoperative serum markers and HHS. In the R-THA cohort, the PLT count was significantly lower on the postoperative day 1 (192.36 ± 41.72 × 109/L Vs 210.47 ± 72.85 × 109/L, p < 0.05). The Hb level was significantly lower on the postoperative third day in the R-THA cohort (98.52 ± 12.99 g/L Vs 104.74 ± 13.15 g/L, p < 0.05). There was no significant difference in the other serum markers between the cohorts on postoperative day 1 and 3 (p > 0.05). The FJS was significantly higher in the R-THA than M-THA group (p = 0.01). There was no significant difference in the postoperative HHS or complication rate between the groups (p > 0.05). The R-THA is not associated with a serious invasiveness compared to M-THA. Patients who underwent R-THA had a better early function compared to those who underwent M-THA.
Collapse
Affiliation(s)
- Mingyang Ma
- Chinese PLA Medical School, Beijing, China
- Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| | - Zheng Cao
- Chinese PLA Medical School, Beijing, China
- Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
- School of Medicine, Nankai University, Tianjin, China
| | - Minzhi Yang
- Chinese PLA Medical School, Beijing, China
- Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| | - Xiangpeng Kong
- Chinese PLA Medical School, Beijing, China.
- Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, China.
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China.
| | - Wei Chai
- Chinese PLA Medical School, Beijing, China.
- Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, China.
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China.
| |
Collapse
|
21
|
Lu X, Zhang Z, Wang W, Xu H, Zhang H. Accuracy and safety of a new robotic arm for both femoral and acetabular side in total hip arthroplasty: a cadaveric study. J Orthop Surg Res 2023; 18:830. [PMID: 37924147 PMCID: PMC10625291 DOI: 10.1186/s13018-023-04263-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/04/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND To investigate the accuracy and safety of a newly constructed robotic arm which can cover the whole process of THA, we performed a series of robot-assisted total hip replacement on the cadaver. METHODS Fifteen frozen cadaveric specimens (30 hips) were used for this study. In this investigation, united hip system and Longwell robotic-assisted system were used. The entire lower limb was CT scanned prior to surgery. The 3D model was produced based on CT data; the site of the prosthesis, including acetabular anteversion, inclination angle, and the position of femoral prosthesis, was planned. With the assistance of a robotic arm, the surgeon changed the parameters based on the preoperative plan and the actual condition during surgery, and completed the whole procedure. Following surgery, we measured the acetabular anteversion angle, acetabular inclination angle, femur anteversion angle, combined anteversion angle, stem angulation, and canal fill ratio. RESULTS The parameters proved that the acetabular anteversion angle was 16.85 ± 3.00°, the acetabular inclination angle was 40.38 ± 5.37°, femur anteversion angle was 15.90 ± 9.01°, combined anteversion angle was 32.75 ± 9.03°, stem angulation was 1.84 ± 0.99°, and leg length discrepancy was 2.47 ± 1.43 mm. The canal fill ratio (CFR) of femoral prosthesis of osteotomy line in sagittal section is 99.72 ± 1.54% and in coronal section is 62.94 ± 8.91%; below osteotomy line 2.5 cm in sagittal section is 100.00% and in coronal section is 81.48 ± 12.94%; below osteotomy line 7.5 cm in sagittal section is 59.51 ± 12.94% and in coronal section is 89.79 ± 11.13%; femoral shaft isthmus in sagittal section is 56.41 ± 13.80% and in coronal section is 84.95 ± 15.17%. CONCLUSION The accuracy and safety of this novel robotic arm are suitable for preparing both the acetabular and femoral sides, providing evidence for clinical trial.
Collapse
Affiliation(s)
- Xinzhe Lu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266100, Shandong, China
| | - Zian Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266100, Shandong, China
| | - Wenzhe Wang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266100, Shandong, China
| | - Hao Xu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266100, Shandong, China
| | - Haining Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266100, Shandong, China.
| |
Collapse
|
22
|
Kim K, Kwon S, Kwon J, Hwang J. A review of robotic-assisted total hip arthroplasty. Biomed Eng Lett 2023; 13:523-535. [PMID: 37872985 PMCID: PMC10590363 DOI: 10.1007/s13534-023-00312-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 08/02/2023] [Accepted: 08/11/2023] [Indexed: 10/25/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful surgical method for hip replacement but still poses challenges and risks. Robotic-assisted THA (rTHA) using new generation robotic systems has emerged to improve surgical precision and outcomes. The purpose of this paper is to review the literature on rTHA, with a focus on its advantages, such as individualized preoperative planning, intraoperative assistance, and improved accuracy in implantation, especially in complex cases. Additionally, it aims to explore the disadvantages associated with the use of rTHA, including high costs, the learning curve, and prolonged operation time compared to manual THA (mTHA), which are critical drawbacks that require careful consideration and efforts for minimization. Some financial analyses suggest that rTHA may offer cost-effectiveness and reduced postoperative costs compared to mTHA. While technological advancements are expected to reduce technical complications, there are still debates surrounding long-term outcomes. Practical limitations, such as limited availability and accessibility, also warrant attention. Although the development of rTHA shows promise, it is still in its early stages, necessitating critical evaluation and further research to ensure optimal patient benefits.
Collapse
Affiliation(s)
- Kwangkyoun Kim
- Department of Orthopaedic Surgery, Gangnam Sacred Heart Hospital, Hallym University School of Medicine, Seoul, South Korea
- Department of Orthopaedic Surgery, Konyang University School of Medicine, Daejeon, South Korea
| | - Seungcheol Kwon
- Department of Orthopaedic Surgery, Gangnam Sacred Heart Hospital, Hallym University School of Medicine, Seoul, South Korea
- Department of Orthopaedic Surgery, Konyang University School of Medicine, Daejeon, South Korea
| | - Junhyuk Kwon
- Department of Orthopaedic Surgery, Gangnam Sacred Heart Hospital, Hallym University School of Medicine, Seoul, South Korea
- Department of Orthopaedic Surgery, Konyang University School of Medicine, Daejeon, South Korea
| | - Jihyo Hwang
- Department of Orthopaedic Surgery, Gangnam Sacred Heart Hospital, Hallym University School of Medicine, Seoul, South Korea
- Department of Orthopaedic Surgery, Konyang University School of Medicine, Daejeon, South Korea
| |
Collapse
|
23
|
Zhuang TF, Wu CJ, Luo SM, Wu WR, Chen JY, Zha ZG, Huan SW, Liu N. Preliminary study of short-term outcomes and learning curves of robotic-assisted THA: comparison between closed platform robotic system and open platform robotic system. BMC Musculoskelet Disord 2023; 24:756. [PMID: 37749526 PMCID: PMC10521502 DOI: 10.1186/s12891-023-06895-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 09/18/2023] [Indexed: 09/27/2023] Open
Abstract
BACKGROUND Both closed platform and open platform robotic-assisted total hip arthroplasty (THA) have recently been recommended as a viable treatment option for achieving accurate positioning of components. Yet, limited studies paid attention to the differences between the closed platform robotic system and the open platform robotic system. Hence, this study aimed to investigate clinical outcomes, radiographic outcomes, complication rates and learning curve of two systems. MATERIALS AND METHODS We retrospectively included 62 patients (31 closed robotic system and 31 open robotic system) who underwent THA between February 2021 and January 2023. The demographics, operating time, cup positioning, complications and hip Harris score were evaluated. Learning curves of operation time was conducted using cumulative sum (CUSUM) analysis. RESULTS There were no differences in surgical time (76.7 ± 12.1 min vs. 72.3 ± 14.8 min), estimated blood loss (223.2 ± 13.2 ml vs. 216.9 ± 17 ml) and Harris Hip score (HHS) between closed platform robotic system and the open platform robotic system. The closed robotic system and the open robotic system were associated with a learning curve of 9 cases and 7 cases for surgical time respectively, based on the satisfying rate of Lewinnek's safe zone outliers (1/31, 96.8%) and no occurrence of complication. Both robotic systems had significant reduction in overall surgical time, the duration of acetabulum registration, and estimated blood loss between learning phase and proficiency phase. CONCLUSION The authors suggest that the surgical outcomes and safe zone outlier rate of the open robotic-assisted THA were similar to those of the closed robotic-assisted THA. These two robotic-assisted are associated with comparable learning curves and both have the precise positioning of acetabular component. From learning phase to proficiency phase, the rate of positions within the safe zone differed only marginally (88.9-100% vs. 85.7-100%) based on a rather low number of patients. This is not a statistically significant difference. Therefore, we suggest that THA undergoing with the robotic-assisted system is the relatively useful way to achieve planned acetabular cup position so far.
Collapse
Affiliation(s)
- Teng-Feng Zhuang
- The First Clinical College, Jinan University, Guangzhou, 510632, China
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Chong-Jie Wu
- The First Clinical College, Jinan University, Guangzhou, 510632, China
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Si-Min Luo
- The First Clinical College, Jinan University, Guangzhou, 510632, China
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Wen-Rui Wu
- The First Clinical College, Jinan University, Guangzhou, 510632, China
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Jun-Yuan Chen
- The First Clinical College, Jinan University, Guangzhou, 510632, China
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Zhen-Gang Zha
- The First Clinical College, Jinan University, Guangzhou, 510632, China
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Song-Wei Huan
- The First Clinical College, Jinan University, Guangzhou, 510632, China.
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China.
| | - Ning Liu
- The First Clinical College, Jinan University, Guangzhou, 510632, China.
- Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, 510632, China.
| |
Collapse
|
24
|
Avram GM, Prill R, Gurau CD, Georgeanu V, Deleanu B, Russu O, Becker R, Predescu V. Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach. INTERNATIONAL ORTHOPAEDICS 2023; 47:2265-2273. [PMID: 37160646 DOI: 10.1007/s00264-023-05835-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 05/01/2023] [Indexed: 05/11/2023]
Abstract
PURPOSE The modified anterolateral approach (Röttinger) for total hip arthroplasty (THA) offers great advantages over conventional approaches, especially concerning early postoperative symptoms, which are mild and well tolerated by patients. Robotic-assisted implantation might facilitate rapid adoption of the modified anterolateral approach without exposing surgeons to risks encountered during the learning curve. This study posits that the use of robotic assistance in conjunction with the modified anterolateral approach for total hip arthroplasty (THA) can provide a substantial enhancement in the accuracy of cup placement in comparison to manual surgery. METHODS Thirty-two robotic-assisted THAs met the inclusion criteria and were matched to 32 conventional cases. Acetabular cup inclination, anteversion, limb-length discrepancy, and acetabular offset were assessed using certified planning software by two independent observers using pre- and postoperative anterior-posterior radiographs. Data was analyzed for normal distribution. Chi2 test was used to determine whether implanted acetabular cups that were within Lewinnek's safe zones were influenced by type of implantation. Effect size estimates and statistical power analysis were also performed to appreciate the appropriateness of the chosen sample size. RESULTS Robotic-assisted implantation was found to significantly improve acetabular cup placement in terms of inclination (p < 0.001) but not anteversion (p = 0.783). Although mean postoperative limb-length discrepancy and mean acetabular offset did not differ between groups, a significantly smaller variance was found in the robotic-assisted group (p < 0.001) and (p = 0.04), respectively. There were no significant differences between the two groups in terms of consistently implanting the acetabular cup within the Lewinnek safe zones p = 0.641 for anteversion and p = 0.230 for inclination, respectively. CONCLUSIONS Our results show that although robotic-assisted acetabular cup implantation performed through the modified anterolateral approach did not significantly differ from conventional implantation, it did offer increased accuracy in cup positioning, acetabular bone preservation, and limb-length restoration.
Collapse
Affiliation(s)
- George Mihai Avram
- Orthopaedics and Traumatology Department, Ponderas Academic Hospital, 014142, Bucharest, Romania.
| | - Robert Prill
- Center of Orthopaedics and Traumatology, Brandenburg Medical School Theodor Fontane, University Hospital Brandenburg/Havel, 14770, Brandenburg a.d.H, Germany
- Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, 14770, Brandenburg a.d.H, Germany
| | - Cristian Dorin Gurau
- Orthopaedics and Traumatology Department, Ponderas Academic Hospital, 014142, Bucharest, Romania
| | - Vlad Georgeanu
- Orthopaedics and Traumatology Department, Clinical Emergency Hospital St. Pantelimon, Bucharest, Romania
| | - Bogdan Deleanu
- Orthopaedics and Traumatology Department, University of Medicine and Pharmacy Victor Babes, Timisoara, Romania
| | - Octav Russu
- Orthopaedic and Traumatology Department, Pharmacy, Sciences and Technology George Emil Palade, University of Medicine, 540139, Targu Mures, Romania
| | - Roland Becker
- Center of Orthopaedics and Traumatology, Brandenburg Medical School Theodor Fontane, University Hospital Brandenburg/Havel, 14770, Brandenburg a.d.H, Germany
- Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, 14770, Brandenburg a.d.H, Germany
| | - Vlad Predescu
- Orthopaedics and Traumatology Department, Ponderas Academic Hospital, 014142, Bucharest, Romania
| |
Collapse
|
25
|
Kamihata S, Ando W, Takao M, Hamada H, Uemura K, Sugano N. Effect of hip flexion contracture on the pelvic sagittal tilt in the supine position: A retrospective case-series study. Mod Rheumatol 2023; 33:1052-1057. [PMID: 36083017 DOI: 10.1093/mr/roac110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 07/20/2022] [Accepted: 08/30/2022] [Indexed: 11/14/2022]
Abstract
OBJECTIVES The functional pelvic plane, which adopts the natural pelvic sagittal tilt in the supine position, is a good reference for determining the cup angle in total hip arthroplasty. However, hip flexion contracture may change pelvic tilt postoperatively by the release of contracture. This study investigated the influence of hip flexion contracture on pelvic sagittal tilt in the supine position. METHODS This study included 300 patients who underwent primary unilateral total hip arthroplasty. We divided the participants into two groups: with a preoperative hip extension angle of <0° (hip flexion contracture group) and without (non-contracture group). The pelvic sagittal tilt and femoral flexion angle were investigated using computed tomography or pelvic radiographs performed preoperatively and postoperatively. RESULTS The femoral flexion angle had significantly reduced postoperatively in the hip flexion contracture group but remained unchanged in the non-contracture group. The preoperative and postoperative pelvic sagittal tilt showed no significant differences between the two groups up to 1 year postoperatively. CONCLUSIONS The influence of hip flexion contracture on the pelvic sagittal tilt in the supine position was minimal. The functional pelvic plane in the supine position could be a good reference to ascertain the cup orientation, even in hip flexion contracture cases.
Collapse
Affiliation(s)
- Satoshi Kamihata
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Wataru Ando
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masaki Takao
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Keisuke Uemura
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| |
Collapse
|
26
|
Kumar V, Patel S, Baburaj V, Rajnish RK, Aggarwal S. Does robotic-assisted surgery improve outcomes of total hip arthroplasty compared to manual technique? A systematic review and meta-analysis. Postgrad Med J 2023; 99:375-383. [PMID: 37294729 DOI: 10.1136/postgradmedj-2021-141135] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Accepted: 12/01/2021] [Indexed: 11/04/2022]
Abstract
BACKGROUND Robot-assisted total hip arthroplasty (THA) is an emerging technology that claims to position implants with very high accuracy. However, there is currently limited data in literature on whether this improved accuracy leads to better long-term clinical outcomes. This systematic review compares the outcomes of THA done with the help of robotic assistance (RA) to those done with conventional manual techniques (MTs). METHODS Four electronic databases were searched for eligible articles that directly compared robot-assisted THA to manual THA and had data on the radiological or clinical outcomes of both. Data on various outcome parameters were collected. Meta-analysis was conducted using a random-effects model with 95% CIs. RESULTS A total of 17 articles were found eligible for inclusion, and 3600 cases were analysed. Mean operating time in the RA group was significantly longer than in the MT group. RA resulted in significantly more acetabular cups being placed inside Lewinnek's and Callanan's safe zones (p<0.001) and had significantly reduced limb length discrepancy compared with MT. There were no statistically significant differences in the two groups in terms of incidence of perioperative complications, need for revision surgery and long-term functional outcome. CONCLUSION RA leads to highly accurate implant placement and leads to significantly reduced limb length discrepancies. However, the authors do not recommend robot-assisted techniques for routine THAs due to lack of adequate long-term follow-up data, prolonged surgical times and no significant differences in the rate of complications and implant survivorship compared with conventional MTs.
Collapse
|
27
|
Homma Y, Zhuang X, Yanagisawa N, Ishii S, Baba T, Ishijima M. Patients With Shorter Stature Exhibit Minimal Hammering Sound Changes During Cementless Stem Insertion in Total Hip Arthroplasty. Arthroplast Today 2023; 21:101136. [PMID: 37193539 PMCID: PMC10182171 DOI: 10.1016/j.artd.2023.101136] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 03/19/2023] [Indexed: 05/18/2023] Open
Abstract
Background Listening to the change in the hammering sound is 1 of the elements used to assess the cementless stem stability. This study aimed to quantitatively investigate the change in the acoustic characteristics between the early and late phases of cementless stem insertion in total hip arthroplasty and to identify which patient characteristics contribute to the change in the hammering sound. Methods The acoustic parameters of the hammering sounds in the early and late phases of cementless taper-wedged stem insertion for 51 hips in 45 patients who underwent total hip arthroplasty (mean age = 68 years, height = 1.56 m, weight = 55.0 kg) were analyzed. Parameters including patient's basic characteristics, radiographical femoral morphology, and canal fill ratio were assessed as potential contributors to the change in the hammering sound. Results The low-frequency bands (0.5-1.0 kHz and 1.0-1.5 kHz) showed the largest changes during stem insertion and were therefore considered key bands for the analysis of sound alterations. Multivariate linear regression analysis showed that height (β = 8.312, P = .013) and proximal canal fill ratio (β = -3.8568, P = .038) were independently associated with the sound alterations. The decision tree analysis identified height (≥1.66 m or <1.66 m) as the best single discriminator for the sound alteration. Conclusions Patients with smaller stature showed the least change in the hammering sound during stem insertion. Understanding the acoustic characteristics of hammering sound alteration during cementless stem insertion may aid in the achievement of optimal stem insertion.
Collapse
Affiliation(s)
- Yasuhiro Homma
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopaedics, Juntendo University, Bunkyo-ku, Tokyo, Japan
- Corresponding author. Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, Japan. Tel.: +3 3813 3111.
| | - Xu Zhuang
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Naotake Yanagisawa
- Clinical Research and Trial Center, Juntendo University, Bunkyo-ku, Tokyo, Japan
| | - Seiya Ishii
- Department of Orthopaedics, Juntendo University, Bunkyo-ku, Tokyo, Japan
| | - Tomonori Baba
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopaedics, Juntendo University, Bunkyo-ku, Tokyo, Japan
| | - Muneaki Ishijima
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopaedics, Juntendo University, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
28
|
Foissey C, Batailler C, Coulomb R, Giebaly DE, Coulin B, Lustig S, Kouyoumdjian P. Image-based robotic-assisted total hip arthroplasty through direct anterior approach allows a better orientation of the acetabular cup and a better restitution of the centre of rotation than a conventional procedure. INTERNATIONAL ORTHOPAEDICS 2023; 47:691-699. [PMID: 36348089 DOI: 10.1007/s00264-022-05624-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 10/24/2022] [Indexed: 11/11/2022]
Abstract
PURPOSE The aim was to investigate the contribution of robotics assisted total hip arthroplasty (THA) through direct anterior approach (DAA) in improving radiographic precision, functional results and complications. METHODS This retrospective study compared 100 primary conventional THA (cTHA) to 50 primary robotic THA (rTHA) through DAA. All cups were placed with the objective of having no anterior overhang while respecting the safe zones (SZ). Radiographic analysis included cup inclination and anteversion, vertical and horizontal changes of the rotation centre (ΔVCOR, ΔHCOR), acetabular and femoral offset. SZ were 30-50° of inclination and 10-30° of anteversion. Outliers were defined as medial displacement of the COR > 5 mm, vertical displacement of the COR > 3 mm superiorly. Harris hip score (HHS) and complications were compared at one year of follow-up. RESULTS The robotic cups were better oriented with 98% in the global SZ versus 68% in the cTHA group (p = 0.0002). The COR was on average better restored in the robotic group in both the horizontal and vertical planes (Δ HCOR = - 5.0 ± 5.0 vs - 3.4 ± 4.9, p = 0.03; Δ VCOR = 1.6 ± 3.3 vs 0.2 ± 2.7, p = 0.04). There were fewer outliers in the rTHA group concerning VCOR (28% versus 10%, p = 0.03). There was no significant difference in HHS and complication rate at one year. CONCLUSION The use of robotics for THA by DAA provided an advantage in controlling the orientation of the cup and the restoration of its rotation centre. Thanks to the 3D planning on CT scan, it allowed to respect the thresholds while avoiding the anterior overhangs.
Collapse
Affiliation(s)
- Constant Foissey
- Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Centre of Excellence, Lyon, France.
| | - Cécile Batailler
- Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Centre of Excellence, Lyon, France
- Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| | - Rémy Coulomb
- 2 Rue de L'École de Médecine, France - Laboratoire de Mécanique Et Génie Civile (LMGC), CNRS-UM1, Centre Hospitalo-Universitaire de Nîmes, Rue du Pr. Robert Debré, 30029 Nîmes, France - Université Montpellier 1, 860 Rue de St-Priest, 34090, Montpellier, France
| | - Dia Eldean Giebaly
- Department of Trauma and Orthopaedics Surgery, University College Hospital, London, UK
| | - Benoit Coulin
- Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Centre of Excellence, Lyon, France
| | - Sébastien Lustig
- Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Centre of Excellence, Lyon, France
- Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| | - Pascal Kouyoumdjian
- 2 Rue de L'École de Médecine, France - Laboratoire de Mécanique Et Génie Civile (LMGC), CNRS-UM1, Centre Hospitalo-Universitaire de Nîmes, Rue du Pr. Robert Debré, 30029 Nîmes, France - Université Montpellier 1, 860 Rue de St-Priest, 34090, Montpellier, France
| |
Collapse
|
29
|
Raj JJ, Thompson M, Whitehouse SL, Jaiprakash A, Varughese I, Crawford RW. Downsizing and minimising medialisation of the acetabular component: Novel technique to preserve bone in THA. Proc Inst Mech Eng H 2023; 237:368-374. [PMID: 36734414 DOI: 10.1177/09544119231152351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Standard practice for acetabular component placement in total hip arthroplasty (THA) is to medialise the acetabular component. Bone preservation techniques during primary THA are beneficial for possible future revisions. The goal of this study is to examine the effect of downsizing and minimising medialisation of the acetabular component on bone resection volume. The volume of bone resected during acetabular preparation for different sizes of components was calculated and the volume of bone preserved by downsizing the cup was determined. Minimising medialisation of the acetabular component by 1-3 mm from the true floor was calculated. Absolute values and percentage of bone volume preserved when acetabular components are downsized or less medialised is presented. Downsizing the acetabular component by one size (2 mm) preserves between 2.6 cm3 (size 40 vs 42) and 8.4 cm3 (size 72 vs 74) of bone volume and consistently reduces resected bone volume by at least 35% (range 35.2%-37.5%). Similarly, reducing medialisation of a 56 mm acetabular cup (as an example of a commonly implanted component) by 3 mm reduces bone loss by 5.9 cm3- 44% less bone volume resection. Downsizing and minimising medialisation of the cup in THA substantially preserves bone which may benefit future revision surgeries. Surgeons could consider implanting the smallest acceptable acetabular shell to preserve bone without compromising on head size.
Collapse
Affiliation(s)
- Jeffrey J Raj
- Queensland University of Technology, Brisbane, QLD, Australia
- Hospital Tengku Ampuan Afzan, Kuantan, Pahang, Malaysia
| | | | | | | | - Ibin Varughese
- Queensland University of Technology, Brisbane, QLD, Australia
| | - Ross W Crawford
- Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
30
|
Gao Y, Chai W, An Z, Chen X, Dong Z, Zhang Z, Jin Z. Effect of Hip Joint Center on Multi-body Dynamics and Contact Mechanics of Hip Arthroplasty for Crowe IV Dysplasia. Orthop Surg 2022; 14:3061-3069. [PMID: 36177845 DOI: 10.1111/os.13272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 03/16/2022] [Accepted: 03/21/2022] [Indexed: 11/27/2022] Open
Abstract
OBJECTIVE To investigate the hip joint forces, Von Mises stress, contact pressure and micro-motion of hip prosthesis for developmental dysplasia of the hip (DDH) patients under different hip joint centers using musculoskeletal (MSK) multi-body dynamics and finite element analysis. METHODS Both MSK multi-body dynamics model and finite element (FE) model were based on CT data of a young female DDH patient with total hip replacement and were developed to study the biomechanics of the S-ROM hip prosthesis. The same offset of hip joint center along all six orientations compared with the standard position was set to predict its effects on both MSK multi-body dynamics and contact mechanics during one gait cycle. RESULTS The hip joint forces in the entire walking gait cycle showed two peak values and clear differences between them under different hip joint centers. The hip joint force increased when the hip joint center moved posteriorly (2101 N) and laterally (1969 N) to the anatomical center (1848 N) at the first peak by 13.7% and 6.6%, respectively. The hip joint force increased sharply when the hip center deviated laterally (2115 N) and anteriorly (2407 N), respectively, from the standard position (1742 N) at the second peak. For the sleeve of the S-ROM prosthesis, the maximum Von Mises stress and contact pressure of the sleeve increased if the hip joint center deviated from the anatomical center posteriorly at the first peak. However, the Von Mises stresses and contact pressure increased at anterior and lateral orientations, compared to that of the standard position at the second peak. Small changes were observed for the maximum relative sliding distance along most of the orientations at both peaks except in the lateral and medial orientations, in which an increase of 8.6% and a decrease of 13.6% were observed, respectively. CONCLUSION The hip joint center obviously influenced the hip joint forces, stress, contact pressure and micro-motion of the hip implant for this female patient.
Collapse
Affiliation(s)
- Yongchang Gao
- National Engineering Laboratory for Highway Maintenance Equipment, Chang'an University, Xi'an, Shaanxi, China
| | - Wei Chai
- Department of Orthopaedics, The Chinese PLA General Hospital, Beijing, China
| | - Zhicheng An
- National Engineering Laboratory for Highway Maintenance Equipment, Chang'an University, Xi'an, Shaanxi, China
| | - Xihui Chen
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China
| | - Zhe Dong
- National Engineering Laboratory for Highway Maintenance Equipment, Chang'an University, Xi'an, Shaanxi, China
| | - Zhifeng Zhang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China
| | - Zhongmin Jin
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China
| |
Collapse
|
31
|
Nakasone S, Takaesu M, Ishihara M, Onaga M, Igei T, Miyata Y, Nishida K. Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device. Arthroplast Today 2022; 16:46-52. [PMID: 35647246 PMCID: PMC9133511 DOI: 10.1016/j.artd.2022.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/30/2022] [Accepted: 04/06/2022] [Indexed: 11/26/2022] Open
Abstract
Background Accurate cup placement during total hip arthroplasty (THA) is difficult because the intraoperative pelvic position changes even in supine patient position. We developed a device known as HipPointer; it corrects pelvic rotation and creates a functional pelvic plane as a reference. The aim of this study was to determine the device placement accuracy and investigate causes of error. Material and methods HipPointer was used for cup placement in 353 hips of 308 patients who underwent direct-anterior-approach THA in supine position. The mean age at surgery and body mass index were 63.9 (17-90) years and 24.9 (16.6-42.0) kg/m2, respectively. The mean observation period was 40.5 (12-73) months. To investigate the accuracy of HipPointer, preoperative planning and postoperative cup placement angles relative to the functional pelvic plane were evaluated using a three-dimensional analysis software, and absolute errors were determined. Results The means ± standard deviations of radiographic inclination (RI) and radiographic anteversion (RA) were 40.2 ± 3.0° and 15.8 ± 3.6°, respectively. The absolute errors of RI and RA were 2.2 ± 2.0° and 2.7 ± 2.3°, respectively. The ratio of the cup placement angle for which both RI and RA are ≤10° in the target zone was 99% (350/353 hips), and the ratio of the absolute errors for which both RI and RA are ≤5° was 80.4% (284/353 hips). Conclusions HipPointer is simple in structure, easy to use, and useful for direct-anterior-approach THA in supine position. It provides good cup placement accuracy.
Collapse
Affiliation(s)
- Satoshi Nakasone
- Department of Orthopedic Surgery, Graduate School of Medicine, University of the Ryukyus, Okinawa, Japan
- Corresponding author. Department of Orthopedic Surgery, Graduate School of Medicine, University of the Ryukyus, 207 Uehara, Nishihara, Nakagamigun, Okinawa 9030125, Japan. Tel.: +81 9889 51174.
| | - Mika Takaesu
- Department of Orthopedic Surgery, Chubu Tokushukai Hospital, Okinawa, Japan
| | - Masato Ishihara
- Department of Orthopedic Surgery, Nakagami Hospital, Okinawa, Japan
| | - Masamichi Onaga
- Department of Orthopedic Surgery, Graduate School of Medicine, University of the Ryukyus, Okinawa, Japan
| | - Takahiro Igei
- Department of Orthopedic Surgery, Graduate School of Medicine, University of the Ryukyus, Okinawa, Japan
| | - Yoshihide Miyata
- Department of Orthopedic Surgery, Chubu Tokushukai Hospital, Okinawa, Japan
| | - Kotaro Nishida
- Department of Orthopedic Surgery, Graduate School of Medicine, University of the Ryukyus, Okinawa, Japan
| |
Collapse
|
32
|
Sato K, Sato A, Okuda N, Masaaki M, Koga H. A propensity score-matched comparison between Mako robotic arm-assisted system and conventional technique in total hip arthroplasty for patients with osteoarthritis secondary to developmental dysplasia of the hip. Arch Orthop Trauma Surg 2022; 143:2755-2761. [PMID: 35819515 DOI: 10.1007/s00402-022-04524-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 06/12/2022] [Indexed: 11/26/2022]
Abstract
BACKGROUND The clinical effectiveness of robotic arm-assisted systems remains unclear for total hip arthroplasty (THA) in patients suffering from osteoarthritis secondary to developmental dysplasia of the hip (DDH). METHODS Patients with DDH who underwent primary THA were included in this study. We conducted a propensity score-matched comparison between THAs using a robotic arm-assisted system (Mako group) versus those using the manual procedure (manual group) to compare the absolute differences in cup placement angles measured using postoperative computed tomography and those planned preoperatively. RESULTS A total of 217 patients with osteoarthritis due to DDH met the inclusion criteria. Eighty-four patients were matched as the Mako group and 84 as the manual group. The differences were smaller in the Mako group than the manual group in terms of both inclination and anteversion angles (1.1 ± 1.0 versus 4.2 ± 3.1, respectively; 95% CI, 2.4 to 3.8; p < 0.0001, and 1.2 ± 1.1 versus 5.8 ± 4.0, respectively; 95% CI, 3.7 to 5.5; p < 0.0001). CONCLUSIONS The robotic arm-assisted system may provide more accurate cup placement in THA for DDH.
Collapse
Affiliation(s)
- Kei Sato
- Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Tokyo, Japan
- Department of Orthopedic Surgery, Nissan Tamagawa Hospital, 4-8-1 Seta Setagaya-ku, Tokyo, Japan
| | - Atsuko Sato
- Department of Orthopedic Surgery, Nissan Tamagawa Hospital, 4-8-1 Seta Setagaya-ku, Tokyo, Japan.
| | - Naoki Okuda
- Department of Orthopedic Surgery, Nissan Tamagawa Hospital, 4-8-1 Seta Setagaya-ku, Tokyo, Japan
| | - Matsubara Masaaki
- Department of Orthopedic Surgery, Nissan Tamagawa Hospital, 4-8-1 Seta Setagaya-ku, Tokyo, Japan
| | - Hideyuki Koga
- Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
33
|
Sicat CS, Buchalter DB, Luthringer TA, Schwarzkopf R, Vigdorchik JM. Intraoperative Technology Use Improves Accuracy of Functional Safe Zone Targeting in Total Hip Arthroplasty. J Arthroplasty 2022; 37:S540-S545. [PMID: 35428540 DOI: 10.1016/j.arth.2022.02.038] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 02/09/2022] [Accepted: 02/10/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Targets of acetabular inclination and anteversion have been suggested based on a patient's spinopelvic mobility. Current methods in total hip arthroplasty (THA) include manual instrumentation, computer-assisted navigation, and robotic-assisted surgery. This study aims to compare the accuracy of these 3 methods in targeting the functional safe zone. METHODS This is a prospective multicenter study including a series of 251 consecutive primary posterior THA patients from April 2019 to January 2021. Preoperative lateral standing and sitting spinopelvic radiographs were obtained. Each patient was classified using the Hip-Spine Classification. A functional safe zone plan was determined. Surgeons used their preferred method (manual instrumentation, computer-assisted, or robotic-assisted). Postoperative anteversion and inclination was measured and compared to the preoperative plan. Mean differences between preoperative and postoperative values were calculated. Welch's t-test was used to assess significant between-group differences with P < .05 considered significant. RESULTS Of the 249 patients, there were 63 manual instrumentation, 68 computer-assisted navigation, and 118 robotic-assisted surgery. Robotic-assisted surgery (rTHA) was significantly more accurate in targeting anteversion (1 ± 2) compared to manual instrumentation (mTHA; 7 ± 6, P < .001) and computer-assisted navigation (cTHA; 6 ± 6, P < .001). rTHA was also significantly more accurate in targeting inclination (1 ± 1) compared to mTHA (8 ± 7, P < .001) and cTHA (6 ± 7, P < .001). Although cTHA had greater accuracy in targeting both inclination and anteversion compared to mTHA, these differences were not statistically significant. CONCLUSION Robotic-assisted surgery was more accurate than both computer-assisted navigation and manual instrumentation in targeting the functional safe zone in primary THA. Further research is needed to evaluate the effect of improved accuracy on dislocation rates.
Collapse
Affiliation(s)
- Chelsea S Sicat
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY
| | | | | | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY
| | | |
Collapse
|
34
|
Zhao X, Cai XZ, Wang W, Wu HB, Wu LD, Ye ZM, Yan SG. MAKO robotic assisted total hip replacement (THR) for patients with fused hips. Int J Med Robot 2022; 18:e2369. [PMID: 35060271 DOI: 10.1002/rcs.2369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/20/2021] [Accepted: 01/11/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Previous articles about MAKO robotic-assisted total hip replacement (THR) were mainly in patients with comparatively normal anatomy. METHODS From July 2020 to June 2021, we performed MAKO robotic-assisted THR in three hip-fused patients. We assessed the accuracy of prostheses implantation, collected clinical data, and discussed the value of this technique in this kind of patients. RESULT All three patients achieved good leg length and prostheses position. A patient got femoral artery injury during the surgery. Moreover, she developed a thrombus. All three patients got acceptable Visual Analogue Scale scores and function recovery 6 months later. CONCLUSION MAKO robotic-assisted THR achieved excellent prosthesis position in hip fused patients. More cases are needed to confirm this advantage. The function recovery was acceptable. Caution should be paid to protect the surrounding abnormal arteries, especially in a limited surgical field.
Collapse
Affiliation(s)
- Xiang Zhao
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| | - Xun-Zi Cai
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| | - Wei Wang
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| | - Hao-Bo Wu
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| | - Li-Dong Wu
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| | - Zhao-Ming Ye
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| | - Shi-Gui Yan
- Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, China.,Department of Orthopaedics, Research Institute of Zhejiang University, Hangzhou, China
| |
Collapse
|
35
|
[Short-term effectiveness of MAKO robot assisted complex total hip arthroplasty]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2022; 36:555-560. [PMID: 35570628 PMCID: PMC9108643 DOI: 10.7507/1002-1892.202109054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE To investigate the short-term effectiveness of MAKO robot assisted complex total hip arthroplasty (THA). METHODS The clinical data of 15 patients (17 hips) underwent MAKO robot assisted complex THA between May 2020 and June 2021 were analyzed retrospectively. There were 5 males and 10 females with the age ranged from 19 to 70 years (median, 49 years), included 9 cases (9 hips) of developmental dysplasia of the hip (Crowe type Ⅱ in 5 hips, type Ⅲ in 1 hip, and type Ⅳ in 3 hips), 1 case (2 hips) of rheumatoid arthritis, 2 cases (3 hips) of ankylosing spondylitis, 3 cases (3 hips) of secondary arthritis with a history of acetabular fracture and internal fixation. The acetabular cup abduction angle and anteversion angle were measured at 3 months after operation, and compared with those measured by MAKO robot system before and immediately after operation. The femoral offset and leg length discrepancy (LLD) were measured at 3 months after operation, which were compared with those before operation. Harris hip score (HHS) and visual analogue scale (VAS) score were used to evaluate hip function before operation and at 3 months after operation. RESULTS All 15 patients (17 hips) completed the operation successfully. The operation time was 75-175 minutes, with an average of 116.3 minutes; the intraoperative blood loss was 100-800 mL, with an average of 381.3 mL. Two patients were not included in the statistics because of intraoperative and postoperative complications, the remaining 13 patients (15 hips) had no serious complication such as vascular and nerve injuries, and 3 patients had intermuscular vein thrombosis. The 13 patients (15 hips) were followed up 3-15 months, with an average of 8 months. At last follow-up, the position of prosthesis did not change and there was no signs of loosening. There was no significant difference in acetabular abduction angle at immediate and 3 months after operation when compared with preoperative one ( P>0.05), and the acetabular anteversion angle was significantly lower than that before operation ( P<0.05). There was no significant difference in acetabular abduction angle and anteversion angle between at immediate and 3 months after operation ( P>0.05). The LLD, offset, HHS score, and VAS score were significantly improved at 3 months after operation when compared with preoperative ones ( P<0.05). CONCLUSION MAKO robot assisted complex THA can achieve good short-term effectiveness, improve the hip range of motion, reduce the length difference between bilateral lower limbs, and improve the quality of patients' life.
Collapse
|
36
|
Kunze KN, Bovonratwet P, Polce EM, Paul K, Sculco PK. Comparison of Surgical Time, Short-term Adverse Events, and Implant Placement Accuracy Between Manual, Robotic-assisted, and Computer-navigated Total Hip Arthroplasty: A Network Meta-analysis of Randomized Controlled Trials. J Am Acad Orthop Surg Glob Res Rev 2022; 6:e21.00200. [PMID: 35472191 PMCID: PMC10566925 DOI: 10.5435/jaaosglobal-d-21-00200] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 02/12/2022] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Recent years have observed the increasing utilization of robotic-assisted and computer navigation techniques in total hip arthroplasty (THA), given the proposed benefits of enhanced consistency and precision in implant placement. The purpose of this study was to conduct a systematic review of randomized controlled trials (RCTs) to determine whether differences in surgical times, adverse events, and implant positioning existed between manual, robotic-assisted, and computer navigation THA. METHODS PubMed, OVID/MEDLINE, and Cochrane databases were queried for RCTs comparing robotic-assisted versus manual THA and computer navigation versus manual THA at a minimum 1-year follow-up. Frequentist model network meta-analyses with P-scores were conducted to compare revisions, complications, and surgical times among the three treatment groups. A random-effects meta-analysis between computer navigation and manual THAs was conducted to analyze cup positioning because no robotic-assisted THA studies reported this outcome. RESULTS Five RCTs compared robotic-assisted and manual THAs, while seven compared computer navigation and manual THAs. manual THA was associated with significantly reduced surgical time in comparison with computer navigation (mean difference: 23.3 minutes) and robotic-assisted THAs (mean difference: 8.6 minutes; P < 0.001). No difference was observed in the incidence of all-cause complications (computer navigation: 1.7%, manual: 6.6%, and robotic-assisted: 16.2%) or revisions (computer navigation: 1.0%, manual: 1.7%, and robotic-assisted 4.8%) among the three treatment groups based on the network meta-analysis. In three studies that reported acetabular implant positioning, computer navigation had a significantly higher percentage of acetabular cups placed in the Lewinnek "safe zone" compared with manual THA (79% versus 52%; P = 0.02). CONCLUSIONS manual THA results in markedly shorter surgical times and a similar incidence of complications and revisions compared with robotic-assisted and computer navigation THAs, given the sample sizes available for study. However, computer navigation THA led to increased precision in the placement of acetabular implants.
Collapse
Affiliation(s)
- Kyle N. Kunze
- From the Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY (Dr. Kunze, Dr. Bovonratwet, and Dr. Sculco), University of Wisconsin School of Medicine and Public Health, Madison, WI (Mr. Polce), and the Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL (Ms. Paul)
| | - Patawut Bovonratwet
- From the Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY (Dr. Kunze, Dr. Bovonratwet, and Dr. Sculco), University of Wisconsin School of Medicine and Public Health, Madison, WI (Mr. Polce), and the Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL (Ms. Paul)
| | - Evan M. Polce
- From the Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY (Dr. Kunze, Dr. Bovonratwet, and Dr. Sculco), University of Wisconsin School of Medicine and Public Health, Madison, WI (Mr. Polce), and the Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL (Ms. Paul)
| | - Katlynn Paul
- From the Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY (Dr. Kunze, Dr. Bovonratwet, and Dr. Sculco), University of Wisconsin School of Medicine and Public Health, Madison, WI (Mr. Polce), and the Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL (Ms. Paul)
| | - Peter K. Sculco
- From the Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY (Dr. Kunze, Dr. Bovonratwet, and Dr. Sculco), University of Wisconsin School of Medicine and Public Health, Madison, WI (Mr. Polce), and the Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL (Ms. Paul)
| |
Collapse
|
37
|
Chai W, Xu C, Guo RW, Kong XP, Fu J, Tang PF, Chen JY. Does robotic-assisted computer navigation improve acetabular cup positioning in total hip arthroplasty for Crowe III/IV hip dysplasia? A propensity score case-match analysis. INTERNATIONAL ORTHOPAEDICS 2022; 46:769-777. [PMID: 34997288 DOI: 10.1007/s00264-021-05232-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 09/24/2021] [Indexed: 11/25/2022]
Abstract
AIMS Total hip arthroplasty (THA) in patients with hip-dislocation dysplasia remains challenging. This study aims to evaluate whether these patients may benefit from robotic-assisted techniques. METHODS We reviewed 135 THAs (108 conventional THAs and 27 robotic-assisted THAs) for Crowe type III or IV from January 2017 to August 2019 in our institution. Robotic-assisted THAs were matched with conventional THAs at a 1:1 ratio (27 hips each group) using propensity score matching. The accuracy of cup positioning and clinical outcomes were compared between groups. RESULTS The inclination of the cup for conventional THAs and robotic THAs was 42.1 ± 5.7 and 41.3 ± 4.6 (p = 0.574), respectively. The anteversion of the cup for conventional THAs was significantly greater than that of robotic THAs (29.5 ± 8.1 and 18.0 ± 4.6; p < 0.001), respectively. The ratio of the acetabular cup in the Lewinnek safe zone was 37% (10/27) in conventional THAs and 96.3% (26/27) in robotic THAs (p < 0.001). Robotic THAs did not achieve better leg length discrepancy than that of conventional THAs (- 0.4 ± 10.9 mm vs. 0.4 ± 8.8 mm, p = 0.774). There was no difference in Harris Hip Score and WOMAC Osteoarthritis index between groups at the 2-year follow-up. No dislocation occurred in all cases at the final follow-up. CONCLUSION Robotic-assisted THA for patients with high dislocation improves the accuracy of the implantation of the acetabular component with respect to safe zone.
Collapse
Affiliation(s)
- Wei Chai
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
- Department of Orthopedics, the First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Chi Xu
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
- Department of Orthopedics, the First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Ren-Wen Guo
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Xiang-Peng Kong
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
- Department of Orthopedics, the First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Jun Fu
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
- Department of Orthopedics, the First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Pei-Fu Tang
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China.
- Department of Orthopedics, the First Medical Center of Chinese PLA General Hospital, Beijing, China.
- Department of Orthopaedics, General Hospital of People's Liberation Army, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.
| | - Ji-Ying Chen
- Senior Department of Orthopedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China.
- Department of Orthopedics, the First Medical Center of Chinese PLA General Hospital, Beijing, China.
- Department of Orthopaedics, General Hospital of People's Liberation Army, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.
| |
Collapse
|
38
|
The use of Mako robot-assisted total hip arthroplasty in the treatment of Crowe IV developmental dysplasia of the hip. Asian J Surg 2022; 45:1333-1335. [PMID: 35241336 DOI: 10.1016/j.asjsur.2022.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 02/11/2022] [Indexed: 11/23/2022] Open
|
39
|
Rajpura A, Asle SG, Ait Si Selmi T, Board T. The accuracy of restoration of femoral head centre of rotation in the anteroposterior plane after uncemented total hip arthroplasty : a CT-based study. Bone Joint Res 2022; 11:180-188. [PMID: 35343251 PMCID: PMC8963361 DOI: 10.1302/2046-3758.113.bjr-2021-0378.r2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIMS Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane. METHODS Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation. RESULTS Overall, 26/40 hips had a centre of rotation displaced posteriorly compared to the contralateral hip, increasing to 33/40 once corrected for sagittal tilt, with a mean posterior displacement of 7 mm. Linear regression analysis indicated that stem anteversion needed to be increased by 10.8° to recreate the head centre in the AP plane. Merely matching the native version would result in a 12 mm posterior displacement. CONCLUSION This study demonstrates the significant incidence of posterior displacement of the head centre in uncemented hip arthroplasty. Effects of such displacement include a reduction in impingement free range of motion, potential alterations in muscle force vectors and lever arms, and impaired proprioception due to muscle fibre reorientation. Cite this article: Bone Joint Res 2022;11(3):180-188.
Collapse
Affiliation(s)
- Asim Rajpura
- Centre for Hip Surgery, Wrightington Hospital, Wigan, UK
| | | | | | - Tim Board
- Orthopaedics, Wrightington Hospital, Wigan, UK
| |
Collapse
|