1
|
Serra PL, Mariani M, Fabbri M, Murone V, Scucchi B, Contessi F, Marin IE, Botti C, Botti G. Capsular Contracture After Breast Augmentation: Our Approach to Prevent Reoccurrence with Combined Total Capsulectomy and Implantation of Motiva Ergonomix® Implants. Aesthetic Plast Surg 2025; 49:1988-1999. [PMID: 39681688 DOI: 10.1007/s00266-024-04547-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2024] [Accepted: 11/11/2024] [Indexed: 12/18/2024]
Abstract
BACKGROUND Breast augmentation is the second most common aesthetic surgery worldwide. Capsular contracture, a prevalent complication which affects up to 30% of patients post-surgery, often leads to further necessary surgeries. OBJECTIVES This study investigates the effectiveness of total capsulectomy combined with Motiva Ergonomix® implant replacement in resolving capsular contracture and minimizing recurrence rates. METHODS We conducted a retrospective study of 1067 patients and enrolled 51 women with capsular contracture post-breast augmentation. Patients were treated between 2014 and 2023 in a single center by three surgeons. Capsular contracture severity was graded using Baker's classification. Surgical interventions included total capsulectomy and implant replacement, using various incision techniques and changes in implant anatomical planes. Patients were followed up for a minimum of 12 months to a maximum of 9 years. RESULTS A total of 51 patients with grade III or IV capsular contracture underwent revisional surgery, involving the implantation of 102 Motiva Ergonomix® prostheses; 77 explanted implants resulted intact, 15 exhibited silicone bleeding, and 10 showed ruptured. Capsular contracture recurrence was observed in only 1.96% of cases during the follow-up period. CONCLUSIONS The combination of total capsulectomy and implantation of Motiva Ergonomix® implants significantly reduces the recurrence rate of capsular contracture. Despite the study's limitations, including its single-center design and a small sample size, our results suggest that this approach is a viable and effective solution to manage this common complication in breast augmentation patients. Further multicentric studies are recommended to validate these results. LEVEL OF EVIDENCE V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://www.springer.com/00266 .
Collapse
Affiliation(s)
- Pietro Luciano Serra
- Plastic Surgery Unit, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari University Hospital Trust, Viale San Pietro 43, 07100, Sassari, Italy.
| | - Marta Mariani
- Department of Plastic and Reconstructive Surgery, Sacred Heart Catholic University, IRCCS A. Gemelli University Polyclinic Foundation, Rome, Italy
| | - Mariachiara Fabbri
- Department of Plastic and Reconstructive Surgery, Sacred Heart Catholic University, IRCCS A. Gemelli University Polyclinic Foundation, Rome, Italy
| | - Vittoria Murone
- Plastic Surgery Resident Residency Program in Plastic Surgery, Azienda Ospedaliera Universitaria Federico II di Napoli, Via Sergio Pansini 5, 80131, Napoli, Italy
| | - Benedetta Scucchi
- Section of Plastic Surgery, Department of Medical and Surgical Specialities, University of Padova, Padova, Italy
| | - Filippo Contessi
- Clinic of Plastic and Reconstructive Surgery, Ospedale Santa Maria della Misericordia, 33100, Udine, Italy
| | - Iulia Elena Marin
- Department of Plastic Reconstructive Surgery and Microsurgery, Careggi University Hospital, 50134, Firenze, Italy
| | - Chiara Botti
- VillaBella Clinic, Via Europa, 55, 25087, Salò, BS, Italy
| | - Giovanni Botti
- VillaBella Clinic, Via Europa, 55, 25087, Salò, BS, Italy
| |
Collapse
|
2
|
Szychta P. Advancements in Aesthetic Breast Augmentation: Evaluating the Safety, Efficacy, and Naturalistic Outcomes of Ergonomix2 Implants. Aesthetic Plast Surg 2024; 48:4351-4364. [PMID: 38580867 DOI: 10.1007/s00266-024-03994-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 03/04/2024] [Indexed: 04/07/2024]
Abstract
BACKGROUND This pioneering study evaluates the safety, efficacy, and Aesthetic outcomes of Ergonomix2 Motiva Ergonomic Implants in breast augmentation. It aims to assess their capability to offer more natural touch and dynamics, delineate the learning curve for surgical techniques, and examine their safety profile compared to Ergonomix1 implants. MATERIALS AND METHODS A prospective cohort study was conducted, comparing 31 patients who received Ergonomix2 implants with a control group of 51 patients with Ergonomix1 implants. Eligible patients were those seeking Aesthetic breast augmentation without prior surgeries or chronic illnesses. Detailed documentation of surgical techniques, implant characteristics, and patient demographics was performed. The study assessed surgical learning curve, implant positioning accuracy, and short-term and early complications. Aesthetic outcomes were evaluated using the BreastQ questionnaire and quantitative elastography. RESULTS Patients with Ergonomix2 implants showed significant improvements in Aesthetic outcomes, including breast contour symmetry and natural feel. The learning curve demonstrated a decrease in surgical time and higher implant positioning accuracy. The safety profile was favorable, with a low complication rate and high patient satisfaction levels. Ergonomix2 implants exhibited enhanced softness and pliability, closely mimicking natural breast tissue, as confirmed by elastographic analyzes. CONCLUSIONS Ergonomix2 implants represent a significant advancement in Aesthetic breast surgery, offering natural-feeling and dynamically adaptable outcomes. Despite the promising results, the need for specialized surgical techniques and further research on long-term safety and efficacy is emphasized. This study contributes foundational knowledge to the field of ergonomic breast implants and their application in modern plastic surgery. LEVEL OF EVIDENCE II This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Collapse
Affiliation(s)
- Pawel Szychta
- Dr Szychta Clinic chirurgiaplastyczna.pl, Zabi Kruk 10, 80-822, Gdansk, Poland.
- Mother's Poland Memorial Hospital - Research Institute, Lodz, Poland.
| |
Collapse
|
3
|
Szychta P. Aesthetic Potential and Safety Profile of Nanotextured Breast Implants in 1000 Cases of Breast Augmentation: Evaluation of a Single-Center Experience. Aesthet Surg J 2024; 44:925-935. [PMID: 38577907 DOI: 10.1093/asj/sjae081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 03/09/2024] [Accepted: 03/14/2024] [Indexed: 04/06/2024] Open
Abstract
BACKGROUND Nanotextured implants, an innovation in implant technology, are designed to enhance tissue interaction, reduce inflammation, and mitigate complications of traditional implants. OBJECTIVES The aim of the study was to evaluate the aesthetic potential and safety profile of nanotextured breast implants in breast augmentation from a single-surgeon experience. METHODS This prospective cohort study included 1000 patients who underwent breast augmentation with nanotextured implants. Aesthetic outcomes were assessed with direct measurements and BCCT.core software, focusing on breast projection, symmetry, and upper pole fullness. Patient satisfaction was measured with BREAST-Q and overall satisfaction surveys. Safety profiles were evaluated based on the incidence of complications such as infection, hematoma, capsular contracture, and implant rupture. Statistical analyses were conducted to assess the outcomes. RESULTS The study found significant improvements in aesthetic outcomes, with 92.8% of cases achieving substantial aesthetic enhancements. Patient satisfaction was high, with 96.4% of patients reporting enhanced self-esteem and contentment. The safety profile was favorable, with a low incidence of complications (0.7% requiring revisional surgery) and no major complications reported. Long-term follow-up data indicated sustained aesthetic outcomes and a stable safety profile. CONCLUSIONS The synergistic quality of nanotextured implants in relation to the natural breast gland tissue is defined by a significantly wider range of aesthetic options. The findings of this study underscore the positive impact of nanotextured breast implants on enhancing the aesthetic potential of breast augmentation and their contribution to a low incidence of complications. LEVEL OF EVIDENCE: 3
Collapse
|
4
|
Szychta P. Achieving Harmonious Feminine Proportions: A Comprehensive Study on Breast Harmonization with Nanotextured Implants. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2024; 12:e5751. [PMID: 38633510 PMCID: PMC11023606 DOI: 10.1097/gox.0000000000005751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 03/06/2024] [Indexed: 04/19/2024]
Abstract
Background The prevalence of breast augmentation as a strategy for achieving idealized feminine proportions, consistent with contemporary beauty standards, has increased notably. This study focuses on the use of nanotextured implants, examining their efficacy in enhancing body symmetry and conforming to current aesthetic ideals. Methods Conducted as a prospective cohort study, this research included women who underwent breast augmentation using nanotextured ergonomic implants from 2017 to 2023. A personalized methodology was applied, incorporating an array of anthropometric measurements and individual motivations to inform the selection of implants. The techniques used aimed at fostering a natural aesthetic, coupled with an extensive postoperative follow-up to evaluate outcomes and identify any complications. Results The study involved 1000 participants, with findings indicating a marked improvement in breast and overall body proportions, in line with targeted aesthetic principles. High levels of patient satisfaction were observed, with more than 90% reporting favorable aesthetic results and a low incidence of complications. These findings emphasize the effectiveness and safety of nanotextured implants in achieving the desired aesthetic goals. Conclusions The study underscores the efficacy of nanotextured implants in attaining balanced feminine proportions, aligning surgical results with modern beauty ideals and enhancing personal well-being. It highlights the significance of a tailored approach in breast augmentation, which encompasses not only the physical aspects of aesthetic enhancement but also the psychological and social facets of patient contentment.
Collapse
Affiliation(s)
- Pawel Szychta
- From Dr Szychta Clinic chirurgiaplastyczna.pl, Gdansk, Poland; and Mother’s Poland Memorial Hospital—Research Institute, Lodz, Poland
| |
Collapse
|
5
|
Lee S, Kim M, Kim M, Ryu W, Back S. Capsular Contracture Rate in Augmentation Mammoplasty With Motiva Breast Implant Insertion: A Single-Center Experience in Korea. Aesthet Surg J 2023; 43:1248-1255. [PMID: 37254824 DOI: 10.1093/asj/sjad166] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 05/21/2023] [Accepted: 05/30/2023] [Indexed: 06/01/2023] Open
Abstract
BACKGROUND Capsular contracture is the most common complication following breast implant surgery, and the implant shell characteristics are important in preventing this complication. OBJECTIVES The aim of this study was to evaluate the capsular contracture rate for SmoothSilk Motiva implants (Establishment Labs Holdings Inc., New York, NY) in females who underwent primary and revisional breast augmentation over a 3-year period. METHODS A total of 1324 cases that took place from 2017 to 2020 were retrospectively analyzed, with 1027 being primary surgeries and 297 being revisional surgeries. RESULTS In the 1324 cases of augmentation mammoplasty with SmoothSilk Motiva implants, the overall capsular contracture rate was 1.8% (n = 24). The capsular contracture rate in the 1027 primary surgery cases was 1.07% (n = 11), and the capsular contracture rate in the 297 revisional surgery cases was significantly different at 4.39% (n = 13, P = .0001). More specifically, the capsular contracture rate in 182 revisional surgery for cases without capsular contracture was 1.12% (n = 2), and it showed no statistically significant difference from the rate in primary surgery cases (P = .965). However, the rate in 115 revisional surgery for cases with capsular contracture was 9.57% (n = 11), and it showed a statistically significant difference from the rate in primary surgery cases (P = .000) and the rate in revisional surgery for cases without capsular contracture (P = .001). CONCLUSIONS Augmentation mammoplasty with SmoothSilk Motiva implants demonstrated a lower rate of capsular contracture than traditional smooth or textured implants. Revisional surgery for cases without capsular contracture showed a similar rate of capsular contracture to primary surgery cases, but the rates were higher in revisional surgery for cases with capsular contracture. LEVEL OF EVIDENCE: 4
Collapse
|
6
|
Ng ZY, Honeyman C, Shoaib T. Single-Institution Early Experience With a New, Smooth, Opaque, and Round Breast Implant Over a 2-Year Period. Aesthet Surg J Open Forum 2023; 5:ojad090. [PMID: 38828093 PMCID: PMC11140518 DOI: 10.1093/asjof/ojad090] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2024] Open
Abstract
Background The ideal breast implant does not exist and the choice of implant for breast augmentation is largely based on what surgeons think will be best for their patients. Objectives To evaluate the preliminary results of a new, smooth, round, and opaque breast implant (PERLE, GC Aesthetics; Dublin, Ireland) from a single-center UK aesthetic practice. Methods Retrospective cohort study of all patients undergoing breast implant surgery with PERLE at the authors' center between January 2021 and December 2022. Outcomes data such as rates of capsular contracture, infection, revision surgery, and synchronous mastopexy were analyzed. Results Of the 385 patients identified, 374 (97.1%) had PERLE implants placed by 3 surgeons for primary (n = 290) and secondary breast augmentation (n = 21), and augmentation-mastopexy (n = 63). Capsular contracture occurred in no cases, infection in 1 (0.2%), and revision surgery in 21 patients (5%). The incision used was always submammary, unless a synchronous mastopexy was performed; implants were placed in the subglandular/subfascial plane in the majority of cases (85.3%), and the rest were dual plane (14.7%). Eight revisions were performed in patients undergoing breast augmentation (due to implant displacement in 6 patients, and hematoma and infection in 1 patient each). Fourteen revisions were performed in those undergoing augmentation-mastopexy. The average follow-up time was 18 months. Conclusions The authors' early, single-center experience with PERLE implants suggests a safety profile and overall complication rate that is comparable with other modern implants. They will continue to monitor the safety and effectiveness of PERLE and discuss the reasons and evolution in the choice of breast implant. Level of Evidence 4
Collapse
Affiliation(s)
| | | | - Taimur Shoaib
- Corresponding Author: Dr Taimur Shoaib, 154 Clyde St, Glasgow G1 4EX, Scotland, UK. E-mail:
| |
Collapse
|
7
|
Hong P, Kang JK, Hwang SH, Lee KA. Feasibility of Imaging Modalities Combined with a Silicone Gel-Filled Breast Implant in Korean Women. Gels 2023; 9:232. [PMID: 36975681 PMCID: PMC10048096 DOI: 10.3390/gels9030232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 02/25/2023] [Accepted: 03/04/2023] [Indexed: 03/19/2023] Open
Abstract
With the occurrence of breast implant crises in Korea, it has become increasingly important to detect complications earlier in patients receiving a device. We have therefore combined imaging modalities with an implant-based augmentation mammaplasty. In this study, we assessed the short-term treatment outcomes and safety of the Motiva ErgonomixTM Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) in Korean women. A total of 87 women (n = 87) were included in the current study. We compared preoperative anthropometric measurements between the right side and the left side of the breast. Moreover, we also compared the thickness of the skin, subcutaneous tissue and the pectoralis major measured on a breast ultrasound preoperatively and 3 months postoperatively. Furthermore, we analyzed the incidences of postoperative complications and the cumulative complication-free survival. Preoperatively, there was a significant difference in the distance from the nipple to the midline between the left and right side of the breast (p = 0.000). Both sides of the breast showed significant differences in the thickness of the pectoralis major preoperatively and 3 months postoperatively (p = 0.000). A total of 11 cases (12.6%) of postoperative complications occurred; these included five cases (5.7%) of early seroma, two cases (2.3%) of infection, two cases (2.3%) of rippling, one case (1.1%) of hematoma and one case (1.1%) of capsular contracture. Time-to-events were estimated at 386.68 ± 27.79 days (95% CI 334.11-439.27). Here, we describe our experience with imaging modalities in combination with the Motiva ErgonomixTM Round SilkSurface in Korean women.
Collapse
Affiliation(s)
- Pa Hong
- Department of Radiology, Samsung Changwon Hospital, Sunkyunkwan University School of Medicine (SKKU-SOM), Changwon 51353, Republic of Korea
| | - Jae Kyoung Kang
- Department of Plastic and Reconstructive Surgery, Jeju National University Hospital, Jeju 63241, Republic of Korea
| | - Seung Hwan Hwang
- AVANT Plastic Surgery & Medical Spa, Seoul 06038, Republic of Korea
| | - Kyung Ah Lee
- Department of Plastic and Reconstructive Surgery, Inje University Haeundae Paik Hospital, Busan 48108, Republic of Korea
- Korean Academic Association of Aesthetic and Reconstructive Breast Surgery, Seoul 04146, Republic of Korea
| |
Collapse
|
8
|
Santanelli di Pompeo F, Sorotos M, Canese R, Valeri M, Roberto C, Giorgia S, Firmani G, di Napoli A. Study of the Effect of Different Breast Implant Surfaces on Capsule Formation and Host Inflammatory Response in an Animal Model. Aesthet Surg J 2023; 43:506-515. [PMID: 36402143 DOI: 10.1093/asj/sjac301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 11/10/2022] [Accepted: 11/11/2022] [Indexed: 11/21/2022] Open
Abstract
BACKGROUND Breast implants are biomaterials eliciting a physiological and mandatory foreign body response. OBJECTIVES The authors designed an animal study to investigate the impact of different implant surfaces on the formation of the periprosthetic capsule, the inflammatory response, and the cellular composition. METHODS The authors implanted 1 scaled-down version of breast implants by different manufactures on 70 female Sprague Dawley rats. Animals were divided into 5 groups of 14 animals. Group A received a smooth implant (Ra ≈ 0.5 µm) according to the ISO 14607-2018 classification, Group B a smooth implant (Ra ≈ 3.2 µm), Group C a smooth implant (Ra ≈ 5 µm), Group D a macrotextured implant (Ra ≈ 62 µm), and Group E a macrotextured implant (Ra ≈ 75 µm). At 60 days, all animals received a magnetic resonance imaging (MRI), and 35 animals were killed and their capsules sent for histology (capsule thickness, inflammatory infiltrate) and immunohistochemistry analysis (cellular characterization). The remaining animals repeated the MRI at 120 days and were killed following the same protocol. RESULTS MRI showed a thinner capsule in the smooth implants (Groups A-C) at 60 days (P < .001) but not at 120 days (P = .039), confirmed with histology both at 60 days (P = .005) and 120 days (P < .001). Smooth implants (Groups A-C) presented a mild inflammatory response at 60 days that was maintained at 120 days and a high M2-Macrophage concentration (anti-inflammatory). CONCLUSIONS Our study confirms that smooth implants form a thinner capsule, inferior inflammatory infiltrate, and a cellular composition that indicates a mild host inflammatory response. A new host inflammatory response classification is elaborated classifying breast implants into mild, moderate, and high.
Collapse
|
9
|
Aitzetmüller-Klietz ML, Yang S, Wiebringhaus P, Wellenbrock S, Öztürk M, Kückelhaus M, Hirsch T, Aitzetmüller-Klietz MM. Complication Rates after Breast Surgery with the Motiva Smooth Silk Surface Silicone Gel Implants-A Systematic Review and Meta-Analysis. J Clin Med 2023; 12:1881. [PMID: 36902667 PMCID: PMC10004118 DOI: 10.3390/jcm12051881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 02/13/2023] [Accepted: 02/23/2023] [Indexed: 03/08/2023] Open
Abstract
BACKGROUND In an era where textured devices are being phased out due to concerns about BIA-ALCL, the Motiva SilkSurface breast implants intend to alleviate historical prosthesis-related complications. However, its safety and feasibility remain unelucidated. METHODS An analysis of Pubmed, Web of Science, Ovid, and Embase databases was performed. A total of 114 studies were identified initially, and 13 of these met the inclusion criteria and were assessed regarding postoperative parameters such as complication rate or follow-up period. RESULTS In 4784 patients who underwent breast augmentation with Motiva SilkSurface breast implants, a total of 250 (5.2%) complications were observed. Short- and medium-term complication rates ranged from 2.8-14.4% and 0.32-16.67%, respectively. The most common complication was early seroma (n = 52, overall incidence = 1.08%), followed by early hematoma (n = 28, overall incidence = 0.54%). The incidence of capsule contracture was 0.54% and breast implant-associated-anaplastic large cell lymphoma was not observed. DISCUSSION Although the majority of the studies in the current literature suggest the distinction of the Motiva SilkSurface breast implants in terms of postoperative complications and capsular contracture, its safety and feasibility need to be further elucidated with well-designed, large-scale, multicenter, prospective case-control studies. Other: No funding was received.
Collapse
Affiliation(s)
- Marie-Luise Aitzetmüller-Klietz
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Siling Yang
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Philipp Wiebringhaus
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Sascha Wellenbrock
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Mahmut Öztürk
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Maximilian Kückelhaus
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Tobias Hirsch
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| | - Matthias Michael Aitzetmüller-Klietz
- Division of Plastic Surgery, University Hospital Muenster, Waldeyerstrasse 1, 48149 Muenster, Germany
- Department for Plastic and Reconstructive Surgery, Institute for Musculoskeletal Medicine, Westfaelische Wilhelms-University Muenster, 48157 Muenster, Germany
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Dorbaumstrasse 300, 48157 Muenster, Germany
| |
Collapse
|
10
|
Kang JJ, Lee H, Park BH, Song YK, Park SE, Kim R, Lee KA. Efficacy of a 4-Week Nurse-Led Exercise Rehabilitation Program in Improving the Quality of Life in Women Receiving a Post-Mastectomy Reconstruction Using the Motiva Ergonomix TM Round SilkSurface. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:16. [PMID: 36612340 PMCID: PMC9819378 DOI: 10.3390/ijerph20010016] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 12/13/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
We assessed the efficacy of a 4-week nurse-led exercise rehabilitation (ER) program in improving the quality of life (QOL) of breast cancer survivors (BCS) receiving an implant-based breast reconstruction. The eligible patients were equally randomized to either of both groups: the intervention group (n = 30; a 4-week nurse-led ER program) and the control group (n = 30; a 4-week physical therapist-supervised one). Both after a 4-week ER program and at baseline, the patients were evaluated for the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30) and Fatigue Severity Scale (FSS) scores. There was a significantly higher degree of increase in global health status/QOL scores, physical functioning scores, role functioning scores, and emotional functioning scores at 4 weeks from baseline in the intervention group as compared with the control group (p = 0.001). However, there was a significantly higher degree of decrease in fatigue scores, nausea/vomiting scores, pain scores, dyspnea scores, and FSS scores in the intervention group as compared with the control group (p = 0.001). In conclusion, our results indicate that a 4-week nurse-led ER program might be effective in the QOL in BCS receiving a post-mastectomy implant-based reconstruction using the Motiva ErgonomixTM Round SilkSurface.
Collapse
Affiliation(s)
- Jung Joong Kang
- Department of Physical Medicine and Rehabilitation, Booboo Medical Healthcare Hospital, Mokpo 58655, Republic of Korea
| | - Hyunho Lee
- Department of Anesthesiology and Pain Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan 44033, Republic of Korea
| | - Bom Hui Park
- Department of Medical Device Management and Research, SAIHST, Sungkyunkwan University, Seoul 06355, Republic of Korea
| | - Yu Kwan Song
- Department of Plastic and Reconstructive Surgery, Chung Ju Mirae Hospital, Chungju 27361, Republic of Korea
| | - Soon Eun Park
- Department of Anesthesiology and Pain Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan 44033, Republic of Korea
| | - Robert Kim
- Department of Medical and Pharmaceutical Affairs, Doctor CONSULT, Seoul 06296, Republic of Korea
| | - Kyung Ah Lee
- Department of Plastic and Reconstructive Surgery, Inje University Haeundae Paik Hospital, 875 Haeun-daero, Busan 48108, Republic of Korea
| |
Collapse
|
11
|
A Shakespearean Dilemma in Breast Augmentation: to Use Drains or not? a Systematic Review : Drains in Breast Augmentation. Aesthetic Plast Surg 2022; 46:1553-1566. [PMID: 35048149 DOI: 10.1007/s00266-021-02693-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Accepted: 11/20/2021] [Indexed: 11/01/2022]
Abstract
BACKGROUND Breast augmentation is one of the most commonly requested and performed plastic surgery procedures. In order to prevent early postoperative complications such as seroma or hematoma, surgical drains could be useful. The aim is to perform a systematic review of the literature on the use of surgical drains in primary breast augmentation. METHODS This review was performed following the PRISMA guidelines. PubMed, SCOPUS, Web of Science and Cochrane Library databases were queried in search of clinical studies describing the use of surgical drains in women undergoing primary breast augmentation with implants and documenting seroma and/or hematoma formation rate and/or infection rate. RESULTS Initial search identified 2596 studies, and 162 were found relevant. Full-text review and application of our inclusion criteria to all retrieved papers produced 38 articles that met inclusion criteria. Among the included studies, 16 papers reported the use of surgical drains in breast augmentation, while in the remaining 22 articles drains were not used. Only 5 studies specifically investigated the role and effectiveness of surgical drains in augmentation mammaplasty and its possible relationship with complication rate such as seroma, hematoma or infection. CONCLUSIONS Despite similar complication rates emerged from the analyzed articles, because of the heterogeneity of the studies, we were not able to demonstrate specifically whether drain use affects the rate of early postoperative complications such as seroma, hematoma and infection. Additional randomized controlled trials are strongly advocated in order to provide the necessary scientific evidence. LEVEL OF EVIDENCE III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Collapse
|
12
|
Lee S, Jeong JP, Sung JY, Choi WS, Moon DS, Kim HC, Kim JH. High-Resolution Ultrasound-Assisted Assessment of Preliminary Short-term Safety Outcomes of an Implant-Based Augmentation Mammaplasty Using a Bioengineered, Cell-Friendly, Smooth-Surface Device in Korean Females. Aesthet Surg J Open Forum 2021; 4:ojab046. [PMID: 35072069 PMCID: PMC8781774 DOI: 10.1093/asjof/ojab046] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The Motiva Ergonomix Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) is one of the representative brands of the fifth generation of a silicone gel-filled breast implant with a microtextured surface. OBJECTIVES In this study, the authors describe preliminary short-term safety outcomes of an implant-based augmentation mammaplasty using the Motiva Ergonomix Round SilkSurface in Korean females. METHODS The authors performed a retrospective analysis of medical records in a total of 69 females (n = 69) receiving an implant-based augmentation mammaplasty using the Motiva Ergonomix Round SilkSurface between September 26, 2017, and December 31, 2020. The authors analyzed incidences of postoperative complications. RESULTS A total of 6 cases (8.7%) of postoperative complications occurred; these include 2 cases (2.9%) of early seroma, 1 case (1.4%) of capsular contracture, 2 cases (2.9%) of alterations in the shape, and 1 case (1.4%) of foreign body sensation. Time-to-events were estimated at 266.81 ± 273.17 days. CONCLUSIONS The authors describe our preliminary short-term safety outcomes of an implant-based augmentation mammaplasty using the Motiva Ergonomix Round SilkSurface in Korean females. But this deserves further large-scale studies with long periods of follow-up. LEVEL OF EVIDENCE 4
Collapse
Affiliation(s)
| | | | | | | | | | | | - Jae Hong Kim
- Corresponding Author: Dr Jae Hong Kim, 9F Kukdong B/D, 596 Gangnam-daero, Gangnam-gu, Seoul 06626, Korea. E-mail:
| |
Collapse
|
13
|
Four-Year Interim Results of the Safety of Augmentation Mammaplasty Using the Motiva Ergonomix TM Round SilkSurface: A Multicenter, Retrospective Study. Aesthetic Plast Surg 2021; 46:209-210. [PMID: 34240237 DOI: 10.1007/s00266-021-02454-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 06/28/2021] [Indexed: 10/20/2022]
|