1
|
Vatteroni G, Pinna G, Trimboli RM, Levi R, Bolengo I, Patrone F, Volpe D, Fernandes B, Bernardi D. Role of ultrasound-guided vacuum-assisted breast biopsy in the management of radiologic-pathologic discordance: a retrospective single-centre study. LA RADIOLOGIA MEDICA 2024; 129:1454-1462. [PMID: 39102107 DOI: 10.1007/s11547-024-01864-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Accepted: 07/26/2024] [Indexed: 08/06/2024]
Abstract
PURPOSE To evaluate the efficacy of US-guided vacuum-assisted biopsy (US-VAB) in radiologic-pathologic (rad-path) discordance in women with suspicious breast lesions. METHODS Two thousand three hundred and sixty patients with 2385 BI-RADS category 4 and 5 lesions underwent percutaneous US-guided CNB. Thirty-six lesions were classified as discordant benign and underwent second-line US-VAB. A 14-gauge needle was utilized for CNB and 10-gauge for US-VAB. Final pathology was the reference standard for women who underwent surgery, imaging follow-up in other cases. Rates of malignancy for US-VAB and subsequent surgery were evaluated. Lesions with upgrade and no upgrade to second-line VAB were compared in terms of patient's age, lesion type and characteristics, size and BI-RADS category. Positive predictive value (PPV), negative predictive value (NPV) for BI-RADS categories and diagnostic performance for second-line US-VAB were calculated. p value < 0.05 was considered statistically significant (t-test, Mann-Whitney, χ2). RESULTS US-VAB identified 10 B2, 9 B3 and 17 B5 lesions with upgrade to malignancy of 47.2% (17/36). There were 8 invasive no special type, 7 ductal in situ, 1 invasive lobular carcinoma and 1 angiosarcoma, and their distribution among BI-RADS categories was: 2/2 in BI-RADS 5 (100%), 12/18 in BI-RADS 4C (67%) and 3/16 in BI-RADS 4B lesions (19%) (p = 0.006). Of the remaining 19 lesions, 6 underwent surgery and 2 were upgraded to ductal carcinoma in situ; 13 underwent radiological follow-up and one resulted malignant. False-negative rate for US-VAB was 15.8% (3/19) with final upgrade to malignancy of 55% (20/36). The univariate analysis revealed mass shape (p = 0.008) and BI-RADS categories (p = 0.006) to be associated with upgrade to malignancy. Sensitivity, specificity, PPV, NPV and accuracy for US-VAB were 85, 100, 100, 84 and 92%, respectively. CONCLUSIONS US-VAB identified almost 50% of cancers missed by CNB, avoiding surgical biopsies and validating as an effective mini-invasive approach in rad-path discordance.
Collapse
Affiliation(s)
- Giulia Vatteroni
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Giulia Pinna
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Rubina Manuela Trimboli
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy.
| | - Riccardo Levi
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Isabella Bolengo
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Francesco Patrone
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Daria Volpe
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Bethania Fernandes
- Department of Pathology, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Daniela Bernardi
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Radiology Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| |
Collapse
|
2
|
Ha SM, Chang JM. [Interpretation of Image-Guided Biopsy Results and Assessment]. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2023; 84:361-371. [PMID: 37051381 PMCID: PMC10083635 DOI: 10.3348/jksr.2022.0164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 02/14/2023] [Accepted: 03/10/2023] [Indexed: 06/19/2023]
Abstract
The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.
Collapse
|
3
|
Axially rigid steerable needle with compliant active tip control. PLoS One 2021; 16:e0261089. [PMID: 34914777 PMCID: PMC8675730 DOI: 10.1371/journal.pone.0261089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 11/23/2021] [Indexed: 11/19/2022] Open
Abstract
Steerable instruments allow for precise access to deeply-seated targets while sparing sensitive tissues and avoiding anatomical structures. In this study we present a novel omnidirectional steerable instrument for prostate high-dose-rate (HDR) brachytherapy (BT). The instrument utilizes a needle with internal compliant mechanism, which enables distal tip steering through proximal instrument bending while retaining high axial and flexural rigidity. Finite element analysis evaluated the design and the prototype was validated in experiments involving tissue simulants and ex-vivo bovine tissue. Ultrasound (US) images were used to provide visualization and shape-reconstruction of the instrument during the insertions. In the experiments lateral tip steering up to 20 mm was found. Manually controlled active needle tip steering in inhomogeneous tissue simulants and ex-vivo tissue resulted in mean targeting errors of 1.4 mm and 2 mm in 3D position, respectively. The experiments show that steering response of the instrument is history-independent. The results indicate that the endpoint accuracy of the steerable instrument is similar to that of the conventional rigid HDR BT needle while adding the ability to steer along curved paths. Due to the design of the steerable needle sufficient axial and flexural rigidity is preserved to enable puncturing and path control within various heterogeneous tissues. The developed instrument has the potential to overcome problems currently unavoidable with conventional instruments, such as pubic arch interference in HDR BT, without major changes to the clinical workflow.
Collapse
|
4
|
Farras Roca JA, Tardivon A, Thibault F, Rouzier R, Klijanienko J. Correlation of ultrasound, cytological, and histological features of 110 benign BI-RADS categories 4C and 5 nonpalpable breast lesions. The Institut Curie's experience. Cancer Cytopathol 2021; 129:479-488. [PMID: 33689204 DOI: 10.1002/cncy.22402] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 11/24/2020] [Accepted: 11/25/2020] [Indexed: 11/05/2022]
Abstract
BACKGROUND The purpose of this study was to determine the pathological and ultrasound (US) features of benign nonpalpable breast lesions (NPBLs) classified as Breast Imaging Reporting and Data System (BI-RADS) category 4C or 5. METHODS Between 2003 and 2007, 849 consecutive NPBLs detected at US and classified as BI-RADS category 4C (505) or 5 (344) initially underwent US-guided fine needle aspiration (FNA) at our institution. Benign diagnoses were established according to surgical excision findings or during a minimal 6-month imaging follow-up (mean, 3.7 years [SD, 2.6 years]). US BI-RADS features were reviewed and compared retrospectively using a chi-square test for the following pathological categories: epithelial and fibrous proliferation (EFP), cystic and papillary lesion (C&P), inflammatory lesion (IL), benign tumor (BT), intramammary lymph node (ILN), intraepithelial proliferative lesion (IPL), and nonspecific morphological alteration (NMA). The performance of FNA in the diagnosis of benignity was assessed. RESULTS Of 849 NPBLs, 110 (12.9%) NPBLs were benign: 88 (17.4%) were BI-RADS category 4C, and 22 (6.4%) were BI-RADS category 5. Forty-four (40%) were EFPs, 21 (19%) were C&Ps, 13 (12%) were NMAs, 11 (10%) were ILs, 11 (10%) were BTs, 8 (7%) were IPLs, and 2 (2%) were ILNs. Lesion shape, US pattern distribution, and posterior features showed statistically significant differences between these categories (P < .05): 33 (75%) EFPs exhibited posterior shadowing, 18 (86%) C&Ps were homogenous, 9 (82%) ILs were heterogeneous, 11 (100%) BTs were homogeneous, 9 (82%) BTs were oval, and 6 (75%) IPLs were irregularly shaped. Of the 110 benign NPBLs, FNA diagnosis was falsely positive in 7 (6%), suspicious in 10 (9%), and benign in 90 (82%), and 3 (3%) were inadequate for diagnosis. CONCLUSION A diverse array of benign NPBLs can be classified as BI-RADS category 4C or 5 on US, each showing specific imaging presentations.
Collapse
Affiliation(s)
| | - Anne Tardivon
- Department of Radiology, Institut Curie, Paris, France
| | | | - Roman Rouzier
- Department of Surgical Oncology, Institut Curie, Paris, France
| | - Jerzy Klijanienko
- Department of Diagnostic and Theragnostic Biology, Institut Curie, Paris, France
| |
Collapse
|
5
|
Jörg I, Wieler J, Elfgen C, Bolten K, Hutzli C, Talimi J, Vorburger D, Choschzick M, Moskovszky L, Dedes K, Varga Z. Discrepancies between radiological and histological findings in preoperative core needle (CNB) and vacuum-assisted (VAB) breast biopsies. J Cancer Res Clin Oncol 2021; 147:749-754. [PMID: 33284380 PMCID: PMC7873108 DOI: 10.1007/s00432-020-03481-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 11/22/2020] [Indexed: 11/25/2022]
Abstract
BACKGROUND Ultrasound (US)-guided breast biopsy is a routine diagnostic method used to correlate imaging finding to a histological diagnosis which is still the gold standard in preoperative diagnostics. The accuracy of US-guided breast biopsies relies on a precise radiologic-histopathologic correlation, which is discussed amongst an interdisciplinary team of gynecologists, radiologists and pathologists. However, false-negative or non-diagnostic biopsy results occur. Hence, a thorough and honest discussion to clarify the reason for discrepancies and to decide the next diagnostic step between specialists of the different disciplines is warranted. In this retrospective study, we analyzed discrepant findings between imaging and pathology results on preoperative breast biopsies. METHODS Core and vacuum-assisted breast biopsies from 232 patients were included in this study. Inclusion criteria were (1) non-diagnostic (B1) category on histology independent from imaging category and (2) histological benign (B2) category with a BIRADS 5 (Breast Imaging Reporting and Data System) rating on imaging. Histological diagnoses were retrieved from all cases. Follow-up data were available in most cases. RESULTS 138 biopsies were classified as B1, 94 biopsies as B2 category. 51 of 138 B1 cases (37%) underwent re-biopsy. Re-biopsy found malignancy (B5) in 19 of 51 cases, and B3/4 (premalignant) lesions in 3 of 51 cases. All B2 cases underwent second-look imaging-diagnosis, in 57 of 94 cases (66%) consecutive direct surgery or re-biopsy. Of these, malignancy was diagnosed histologically in 26 of 57 cases (45.6%). CONCLUSION Determining imaging-pathology concordance after US-guided breast biopsy is essential. Discrepant cases and further diagnostic steps need to be discussed with an interdisciplinary approach.
Collapse
Affiliation(s)
- Inna Jörg
- Department of Gynecology, Hospital Triemli, Zurich, Switzerland
- Department of Gynecology, Hospital Zollikerberg, Zollikerberg, Switzerland
| | - Jann Wieler
- Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Constanze Elfgen
- Breast Center Seefeld, Zurich, Switzerland
- Department of Radiology, University Witten-Herdecke, Witten, Germany
| | - Kristina Bolten
- Department of Gynecology, Hospital Zollikerberg, Zollikerberg, Switzerland
| | - Claudia Hutzli
- Department of Gynecology, Hospital Männedorf, Zurich, Switzerland
| | - Julia Talimi
- Breast Center, University Hospital Zurich, Zurich, Switzerland
- Comprehensive Cancer Center Zurich, University Hospital Zurich, Zurich, Switzerland
| | - Denise Vorburger
- Breast Center, University Hospital Zurich, Zurich, Switzerland
- Comprehensive Cancer Center Zurich, University Hospital Zurich, Zurich, Switzerland
| | - Matthias Choschzick
- Institute of Pathology and Molecular Pathology, University Hospital Zurich, Schmelzbergstrasse 12, 8091, Zurich, Switzerland
| | - Linda Moskovszky
- Institute of Pathology and Molecular Pathology, University Hospital Zurich, Schmelzbergstrasse 12, 8091, Zurich, Switzerland
| | - Konstantin Dedes
- Breast Center, University Hospital Zurich, Zurich, Switzerland
- Comprehensive Cancer Center Zurich, University Hospital Zurich, Zurich, Switzerland
| | - Zsuzsanna Varga
- Comprehensive Cancer Center Zurich, University Hospital Zurich, Zurich, Switzerland.
- Institute of Pathology and Molecular Pathology, University Hospital Zurich, Schmelzbergstrasse 12, 8091, Zurich, Switzerland.
| |
Collapse
|
6
|
Zheng X, Huang Y, Liu Y, Wang Y, Mao R, Li F, Cao L, Zhou J. Shear-Wave Elastography of the Breast: Added Value of a Quality Map in Diagnosis and Prediction of the Biological Characteristics of Breast Cancer. Korean J Radiol 2020; 21:172-180. [PMID: 31997592 PMCID: PMC6992439 DOI: 10.3348/kjr.2019.0453] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 09/26/2019] [Indexed: 12/31/2022] Open
Abstract
Objective To determine the added value of a shear-wave elastography (SWE) quality map (QM) in the diagnosis of breast lesions and in predicting the biological characteristics of invasive breast cancer. Materials and Methods Between January 2016 and February 2019, this study included 368 women with 368 pathologically proven breast lesions, which appeared as poor-quality regions in the QM of SWE. To measure shear-wave velocity (SWV), seven regions of interest were placed in each lesion with and without QM guidance. Under QM guidance, poor-quality areas were avoided. Diagnostic performance was calculated for mean SWV (SWVmean), max SWV (SWVmax), and standard deviation (SD) with QM guidance (SWVmean + QM, SWVmax + QM, and SD + QM, respectively) and without QM guidance (SWVmean − QM, SWVmax − QM, and SD − QM, respectively). For invasive cancers, the relationship between SWV findings and biological characteristics was investigated with and without QM guidance. Results Of the 368 women (mean age, 47 years; SD, 10.8 years) enrolled, 159 had benign breast lesions and 209 had malignant breast lesions. SWVmean + QM (3.6 ± 1.39 m/s) and SD + QM (1.02 ± 0.84) were significantly different from SWVmean − QM (3.29 ± 1.22 m/s) and SD − QM (1.46 ± 1.06), respectively (all p < 0.001). For differential diagnosis of breast lesions, the sensitivity and areas under the receiver operating characteristic curve (AUC) of SWVmean + QM (sensitivity: 89%; AUC: 0.932) were better than those of SWVmean − QM (sensitivity, 84.2%; AUC, 0.912) (all p < 0.05). There was no significant difference in sensitivity and specificity between SD + QM and SD − QM (all p = 1.000). Among the biological characteristics of invasive cancers, lymphovascular involvement, axillary lymph node metastasis, negative estrogen receptor status, negative progesterone receptor status, positive human epidermal growth factor receptor status, and aggressive molecular subtypes showed higher SWVmean + QM (all p < 0.05), while only lymphovascular involvement showed higher SWVmean − QM (p = 0.036). Conclusion The use of QM in SWE might improve the diagnostic performance for breast lesions and facilitate prediction of the biological characteristics of invasive breast cancers.
Collapse
Affiliation(s)
- Xueyi Zheng
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Yini Huang
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Yubo Liu
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Yun Wang
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Rushuang Mao
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Fei Li
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Longhui Cao
- Department of Anesthesiology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Jianhua Zhou
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China.
| |
Collapse
|
7
|
Radiologic-Pathologic Correlation for Nondiagnostic CT-Guided Lung Biopsies Performed for the Evaluation of Lung Cancer. AJR Am J Roentgenol 2020; 215:116-120. [PMID: 32160056 DOI: 10.2214/ajr.19.22244] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE. For nondiagnostic CT-guided lung biopsies, we tested whether radiologicpathologic correlation could identify patients who may benefit from repeat biopsy. MATERIALS AND METHODS. In this retrospective study, 1525 lung biopsies were performed between July 2013 and June 2017, 243 of which were nondiagnostic. Of these 243 lung biopsies, 98 were performed to evaluate for lung malignancy; 17 were excluded because of insufficient follow-up, leaving a total of 81 cases. The Brock and Herder models were used to calculate risk; in addition, cases were independently blindly reviewed by two thoracic radiologists who assigned a score from 1 (probably benign) to 5 (probably malignant). The final diagnosis was established by pathology results or benignancy was established if the lesion resolved or remained stable for at least 2 years. RESULTS. Of the 81 nondiagnostic lung biopsies, initial pathology results included 33 cases of inflammation, 28 cases of normal lung tissue or insufficient sample, 10 cases of organizing pneumonia, and 10 cases of atypical cells. 42% (34/81) of cases were eventually determined to be malignant (negative predictive value [NPV] of 58%). Pathology results of organizing pneumonia had the lowest rate of malignancy (2/10 = 20%), and pathology results of atypical cells had the highest rate of malignancy (5/10 = 50%, p = 0.51). Within this highly selected cohort, the Brock and Herder models were not predictive of malignancy, with areas under the ROC curve (AUCs) of 0.52 and 0.52, respectively. Evaluation by thoracic radiologists yielded AUCs of 0.85 and 0.77. When radiologist-assigned scores of 1 and 2 were considered as benign, the NPV was 90% and 95%. CONCLUSION. Review of nondiagnostic lung biopsies for radiologic-pathologic concordance by thoracic radiologists can triage patients who may benefit from repeat biopsy.
Collapse
|
8
|
Khashei Varnamkhasti Z, Konh B. Design and Performance Study of a Novel Minimally Invasive Active Surgical Needle. J Med Device 2019. [DOI: 10.1115/1.4044526] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Abstract
Many medical treatments such as brachytherapy, thermal ablation, and biopsy are performed using percutaneous needle-based procedures. The success of these procedures highly depends on accurate placement of the needle tip at target positions. A novel active needle was designed and developed in this work that can steer inside the tissue via a shape memory alloy (SMA) actuator attached to its body. With actuation and control offered by the actuator, the active needle can reach the target positions with more accuracy, and thereby potential improvement in clinical outcomes. An integrated system was also developed to robotically operate the active needle insertion. The performance of the active needle was evaluated with finite element methods and experimental tests on a fabricated prototype in air. Active needle insertion tests in a tissue phantom were also performed to evaluate the performance of the active needle. The deflection in air and tissue phantom demonstrated the capability of the active needle to reach target positions.
Collapse
Affiliation(s)
| | - Bardia Konh
- Department of Mechanical Engineering, University of Hawaii at Manoa, Honolulu, HI 96822
| |
Collapse
|
9
|
Abstract
SummaryMany medical procedures such as brachytherapy, thermal ablations, and biopsies are performed using needle-based procedures. In this work, 3D manipulation of an active needle realized by multiple Shape Memory Alloy (SMA) actuators was first predicted by Finite Element Analyses (FEA), and then demonstrated by a fabricate prototype. The FEA results were validated by planar deflection of an active needle. A similar FEA was developed to predict 3D manipulation of the active needle. For 17-gage needle, a maximum of 26° reversible deflection was achieved in 3D space via actuation forces of a 0.127 mm SMA wire. A scaled prototype was also developed and tested to show the feasibility of developing a 3D steering active needle with multiple actuators.
Collapse
|
10
|
Nakano S, Imawari Y, Mibu A, Otsuka M, Oinuma T. Differentiating vacuum-assisted breast biopsy from core needle biopsy: Is it necessary? Br J Radiol 2018; 91:20180250. [PMID: 29975150 DOI: 10.1259/bjr.20180250] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Needle biopsy has replaced excisional biopsy as a definitive diagnostic technique for breast tumours, although excisional biopsy is still used for complete tumour removal for therapeutic and/or diagnostic purposes. Many vacuum-assisted breast biopsy (VAB) systems have been made available by several manufacturers since the release of the Mammotome (MMT) by Johnson & Johnson in 1995. Several recent discussions have been conducted to identify whether core needle biopsy (CNB) or VAB, is more appropriate. However, currently available VAB systems differ from the conventional system (i.e. articulate arm type 11-gauge(G) MMT), and the characteristics of both CNB and VAB have been improved. In CNB, a 14-G needle is frequently used to obtain a larger sample. By contrast, VAB is considered easier to perform because it uses a thinner needle and a lighter, non-tethered system. When differentiating CNB from VAB, the type of VAB should also be defined. In this review, we discuss the characteristics of ultrasonography-guided VAB and CNB with a focus on practical issues such as the number of samples and volume of tissue obtained during ultrasonography-guided needle biopsy.
Collapse
Affiliation(s)
- Satoko Nakano
- 1 Department of Breast Surgery, Kawaguchi Municipal Medical Center , Kawaguchi , Japan
| | - Yoshimi Imawari
- 1 Department of Breast Surgery, Kawaguchi Municipal Medical Center , Kawaguchi , Japan
| | - Akemi Mibu
- 1 Department of Breast Surgery, Kawaguchi Municipal Medical Center , Kawaguchi , Japan
| | - Masahiko Otsuka
- 2 Department of Surgery, Kawaguchi Municipal Medical Center , Kawaguchi , Japan
| | - Toshinori Oinuma
- 3 Department of Pathology, Kawaguchi Municipal Medical Center , Kawaguchi , Japan
| |
Collapse
|
11
|
Sohn YM, Seo M. Breast lesions diagnosed by ultrasound-guided core needle biopsy: Can shearwave elastography predict histologic upgrade after surgery or vaccuum assisted excision? Clin Imaging 2018. [PMID: 29524785 DOI: 10.1016/j.clinimag.2018.03.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
PURPOSE To compare breast stiffness based on shear-wave elastography (SWE) quantitative parameters with histopathologic results diagnosed by ultrasound (US)-guided core needle biopsy (CNB) to determine their association with upgrade rates after surgical excision or follow-up US as well as clinico-radiologic differences between upgrade and non-upgrade groups. MATERIALS AND METHODS This retrospective study enrolled 225 breast lesions from 225 patients, including 159 benign lesions, 38 high risk lesions and 28 ductal carcinoma in situ (DCIS) diagnosed by US-guided CNB. Quantitative SWE parameters of breast lesions were measured before CNB and compared according to histopathologic results (benign, high risk and DCIS) and lesion size (<20 mm and >20 mm). Clinico-radiologic and pathologic factors were compared between upgrade and non-upgrade groups after surgical excision or follow-up US. RESULTS After surgical excision or follow-up US after more than one year, 29 lesions were upgraded for an overall upgrade rate of 12.9% (29/225). There were significant differences between upgrade and non-upgrade groups in age, mammographic category, US category, and sonographic features, including shape, margin, orientation, imaging-histologic correlation and E ratio. Patients with lesion upgrade were much older and had lesions characterized by significantly higher mammographic and US category (>4b), irregular shape, nonparallel orientation, microlobulated or angular margin, calcification in a mass, larger size on US (>20 mm) and greater imaging-histologic discordance. Multivariate analysis showed only mean and minimum elasticity values displayed a borderline association with histologic underestimation. CONCLUSION Upgrade of breast lesions diagnosed by US-guided CNB can be predicted using Emean and Emin among quantitative SWE parameters.
Collapse
Affiliation(s)
- Yu-Mee Sohn
- Department of Radiology, Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Seoul, South Korea.
| | - Mirinae Seo
- Department of Radiology, Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Seoul, South Korea
| |
Collapse
|
12
|
Jung I, Kim MJ, Moon HJ, Yoon JH, Kim EK. Ultrasonography-guided 14-gauge core biopsy of the breast: results of 7 years of experience. Ultrasonography 2018; 37:55-62. [PMID: 28641365 PMCID: PMC5769943 DOI: 10.14366/usg.17028] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 04/28/2017] [Accepted: 05/17/2017] [Indexed: 11/26/2022] Open
Abstract
PURPOSE This study assessed the outcomes of ultrasound (US)-guided core needle biopsies (CNBs) of breast lesions with at least 2 years of follow-up to determine the false-negative rate and to evaluate the diagnostic accuracy of CNB. METHODS We retrospectively analyzed 13,254 consecutive US-guided 14-gauge CNBs for breast lesions. We excluded biopsies if non-malignant biopsy result was not confirmed by surgical excision or US-guided vacuum-assisted biopsy, or fewer than 2 years of follow-up data were available. A total of 4,186 biopsies were excluded, and 9,068 breast masses from 7,039 women were included. The pathologic findings from each CNB were assessed using the standard diagnostic reference, defined based on the results of surgical excision, vacuum-assisted biopsy, or at least 2 years of long-term imaging follow-up. The false-negative rate and underestimation rate were calculated. RESULTS Of the 9,068 CNBs, benign pathology was found in 64.2%, high-risk results in 3.5%, and malignant results in 32.3%. Of the 5,821 benign CNBs, an additional malignancy was found at excision in 63 lesions, leading to a false-negative rate of 2.0% (63 of 3,067). The underestimation rate was 33.6% (111 of 330) for ductal carcinoma in situ and 24.5% (79 of 322) for high-risk results at surgical excision. Most false-negative diagnoses (84.1%, 53 of 63) were recognized through imaging-histology correlations, and immediate rebiopsies were performed. Ten malignancies (15.9%, 10 of 63) had delayed diagnoses and showed progression in follow-up US imaging. CONCLUSION US-guided 14-gauge CNB provided optimal diagnostic information. Imaging-histology correlations and appropriate imaging follow-up should be performed to avoid delayed diagnoses.
Collapse
Affiliation(s)
- Inha Jung
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Moon
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jung Hyun Yoon
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Eun-Kyung Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
13
|
Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles. Clin Breast Cancer 2017; 17:536-543. [DOI: 10.1016/j.clbc.2017.02.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 02/26/2017] [Accepted: 02/27/2017] [Indexed: 11/20/2022]
|
14
|
You JY, Suh HJ, Kim Y, Jun JK, Ojeda-Fournier H, Ko K. Follow-up Outcomes of Benign Pathology Initially Assigned as Breast Imaging Reporting and Data System Category 4A and 3. J Breast Cancer 2017; 20:304-309. [PMID: 28970857 PMCID: PMC5620446 DOI: 10.4048/jbc.2017.20.3.304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Accepted: 09/01/2017] [Indexed: 11/30/2022] Open
Abstract
PURPOSE This retrospective study investigated if the initially assigned category 4A or 3 in concordant benign lesions, after ultrasound (US)-guided core needle biopsy, could affect follow-up compliance. METHODS Eight hundred thirty-eight concordant benign lesions, after core needle biopsy (674, initial category 4A group and 164, category 3 group) and follow-up US, were included in our study. If an immediate surgical excision-a surgical excision before the next follow-up-exists, those cases with pathologic reports were collected. Statistical comparisons for the result of follow-up US compliance, additional biopsy, and malignant rates among 6-month, 12-month, and long-term intervals were performed by using the chi-square test. The log-rank test was used to compare compliance rates in the timing of first follow-up between the two groups, with a significance level of 0.05. RESULTS The number of immediate surgical excision was higher in the category 4A group (11.1%) than in the category 3 group (6.1%); only one cancer was found in the category 4A group. The patients' compliance rate in a 6-month follow-up showed an increase (p=0.003) in the category 4A group. The additional biopsy rate was higher in the initial category 4A group (10.9%) than in the category 3 group (1.9%) with statistical significance (p=0.001); four cancers were found on additional biopsy in the category 4 group. No cancer was detected in the initial category 3 group, both on immediate surgical excision and follow-up. CONCLUSION The initial category 4A or 3 of the Breast Imaging Reporting and Data System could be a significant factor that affects immediate surgical excision and follow-up compliance. Cancers were detected only in the initial category 4A group of concordant benign lesions. More attention should be paid to the concordant benign lesions from the initial category 4A group than from the category 3 group.
Collapse
Affiliation(s)
- Ji Young You
- Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, Goyang, Korea
| | - Hee Jung Suh
- Cancer Prevention and Early Detection Center, National Cancer Center, Goyang, Korea
| | - Yunju Kim
- Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, Goyang, Korea
| | - Jae Kwan Jun
- National Cancer Control Institute, National Cancer Center, Goyang, Korea
| | - Haydee Ojeda-Fournier
- Department of Radiology, Moores Cancer Center, UC San Diego Health System, La Jolla, USA
| | - Kyounglan Ko
- Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, Goyang, Korea
| |
Collapse
|
15
|
Spinelli Varella MA, Teixeira da Cruz J, Rauber A, Varella IS, Fleck JF, Moreira LF. Role of BI-RADS Ultrasound Subcategories 4A to 4C in Predicting Breast Cancer. Clin Breast Cancer 2017; 18:e507-e511. [PMID: 29066139 DOI: 10.1016/j.clbc.2017.09.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Revised: 09/01/2017] [Accepted: 09/07/2017] [Indexed: 11/26/2022]
Abstract
BACKGROUND The Breast Imaging Reporting and Data System (BI-RADS) ultrasound (US) categorization revised in 2013 by the American College of Radiology resulted in unquestionable standardization of reports and confirmed category 3 and 5 as benign and malignant lesions, respectively. In contrast, suspected images (category 4) have subcategorization criteria, although theses have been detailed difficult to apply. The aim of the present study was to determine the role of the US 4A to 4C BI-RADS subcategories in predicting malignancy. PATIENTS AND METHODS We performed a cross-sectional study of diagnostic tests to estimate the performance of the US BI-RADS categorization to clearly differentiate benign from malignant lesions. A total of 975 US examinations performed at the Hospital Femina, Grupo Hospitalar Conceição teaching hospitals from January 2012 through March 2015 were included in the present study. The US BI-RADS lexicon was used to classify the examination findings. Suspicious lesions underwent core needle biopsy, and the US and histology reports were compared to determine the performance using receiver operating characteristic curves. RESULTS Overall, the BI-RADS US categorization showed good discriminating accuracy with a receiver operating characteristic curve of 91% (95% confidence interval [CI], 88%-93%). However, BI-RADS subcategory 4b had a positive predictive value of 25% (95% CI, 20%-31%) and subcategory 4A had a positive predictive value of only 6% (95% CI, 3.5%-9.8%). CONCLUSION Our results have shown that US BI-RADS subcategories 4A and 4B are clearly unfit for use in screening tests, because they cannot rule out the need for biopsy. Therefore, management will not be improved by subcategorizing category 4, because all suspicious lesions will still require definite biopsy.
Collapse
Affiliation(s)
- Miguel Angelo Spinelli Varella
- Postgraduate Programme of Surgery, Faculty of Medicine, Rio Grande do Sul Federal University; Department of General and Breast Surgery, Hospital Femina, Grupo Hospitalar Conceição, Ministério da Saúde, Porto Alegre, Brazil.
| | - Jackson Teixeira da Cruz
- Department of Radiology, Ultrasonography Section, Hospital Femina, Grupo Hospitalar Conceição, Ministério da Saúde, Porto Alegre, Brazil
| | - Andrea Rauber
- Department of Gynecology and Obstetrics, Hospital Femina, Grupo Hospitalar Conceição, Ministério da Saúde, Porto Alegre, Brazil
| | - Ivana Santos Varella
- Postgraduate Programme of Epidemiology, Faculty of Medicine, Rio Grande do Sul Federal University; Núcleo de Epidemiologia Hospitalar do Grupo Hospitalar Conceição, Ministério da Saúde, Porto Alegre, Brazil
| | - James Freitas Fleck
- Department of Clinical Oncology, Rio Grande do Sul Federal University; Brazilian Research Council (Conselho Nacional de Pesquisa), Porto Alegre, Brazil
| | - Luis Fernando Moreira
- Department of Surgery, Postgraduate Programme of Surgery, Faculty of Medicine, Rio Grande do Sul Federal University and Hospital de Clínicas de Porto Alegre University Attached Hospital, Porto Alegre, Brazil
| |
Collapse
|
16
|
Park VY, Kim EK, Moon HJ, Yoon JH, Kim MJ. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy. Ultrasonography 2017; 37:107-120. [PMID: 29169231 PMCID: PMC5885481 DOI: 10.14366/usg.17049] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 08/17/2017] [Accepted: 08/19/2017] [Indexed: 11/04/2022] Open
Abstract
Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies.
Collapse
Affiliation(s)
- Vivian Youngjean Park
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Eun-Kyung Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Moon
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jung Hyun Yoon
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
17
|
|
18
|
Scali M, Pusch TP, Breedveld P, Dodou D. Needle-like instruments for steering through solid organs: A review of the scientific and patent literature. Proc Inst Mech Eng H 2017; 231:250-265. [PMID: 28056627 DOI: 10.1177/0954411916672149] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
High accuracy and precision in reaching target locations inside the human body is necessary for the success of percutaneous procedures, such as tissue sample removal (biopsy), brachytherapy, and localized drug delivery. Flexible steerable needles may allow the surgeon to reach targets deep inside solid organs while avoiding sensitive structures (e.g. blood vessels). This article provides a systematic classification of possible mechanical solutions for three-dimensional steering through solid organs. A scientific and patent literature search of steerable instrument designs was conducted using Scopus and Web of Science Derwent Innovations Index patent database, respectively. First, we distinguished between mechanisms in which deflection is induced by the pre-defined shape of the instrument versus mechanisms in which an actuator changes the deflection angle of the instrument on demand. Second, we distinguished between mechanisms deflecting in one versus two planes. The combination of deflection method and number of deflection planes led to eight logically derived mechanical solutions for three-dimensional steering, of which one was dismissed because it was considered meaningless. Next, we classified the instrument designs retrieved from the scientific and patent literature into the identified solutions. We found papers and patents describing instrument designs for six of the seven solutions. We did not find papers or patents describing instruments that steer in one-plane on-demand via an actuator and in a perpendicular plane with a pre-defined deflection angle via a bevel tip or a pre-curved configuration.
Collapse
Affiliation(s)
- Marta Scali
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - Tim P Pusch
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - Paul Breedveld
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - Dimitra Dodou
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| |
Collapse
|
19
|
Can Breast Cancer Biopsy Influence Sentinel Lymph Node Status? Clin Breast Cancer 2016; 16:e153-e157. [DOI: 10.1016/j.clbc.2016.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Revised: 05/22/2016] [Accepted: 06/05/2016] [Indexed: 11/18/2022]
|
20
|
Yoon JH, Kim MJ, Lee HS, Kim SH, Youk JH, Jeong SH, Kim YM. Validation of the fifth edition BI-RADS ultrasound lexicon with comparison of fourth and fifth edition diagnostic performance using video clips. Ultrasonography 2016; 35:318-26. [PMID: 27184655 PMCID: PMC5040135 DOI: 10.14366/usg.16010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 03/23/2016] [Accepted: 03/28/2016] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study was to evaluate the positive predictive value (PPV) and the diagnostic performance of the ultrasonographic descriptors in the fifth edition of BI-RADS, comparing with the fourth edition using video clips. Methods From September 2013 to July 2014, 80 breast masses in 74 women (mean age, 47.5±10.7 years) from five institutions of the Korean Society of Breast Imaging were included. Two radiologists individually reviewed the static and video images and analyzed the images according to the fourth and fifth edition of BI-RADS. The PPV of each descriptor was calculated and diagnostic performances between the fourth and fifth editions were compared. Results Of the 80 breast masses, 51 (63.8%) were benign and 29 (36.2%) were malignant. Suspicious ultrasonographic features such as irregular shape, non-parallel orientation, angular or spiculated margins, and combined posterior features showed higher PPV in both editions (all P<0.05). No significant differences were found in the diagnostic performances between the two editions (all P>0.05). The area under the receiver operating characteristics curve was higher in the fourth edition (0.708 to 0.690), without significance (P=0.416). Conclusion The fifth edition of the BI-RADS ultrasound lexicon showed comparable performance to the fourth edition and can be useful in the differential diagnosis of breast masses using ultrasonography.
Collapse
Affiliation(s)
- Jung Hyun Yoon
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Hye Sun Lee
- Biostastistics Collaboration Unit, Medical Research Center, Yonsei University College of Medicine, Seoul, Korea
| | - Sung Hun Kim
- Department of Radiology, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Ji Hyun Youk
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Sun Hye Jeong
- Department of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon, Korea
| | - You Me Kim
- Department of Radiology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea
| |
Collapse
|
21
|
Adams MC, Falcon S, Mooney BP, Laronga C, Chau A, Drukteinis JS. Short-term imaging follow-up of patients with concordant benign breast core needle biopsies: is it really worth it? Diagn Interv Radiol 2015; 20:464-9. [PMID: 25205024 DOI: 10.5152/dir.2014.14023] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE Women with histologically proven concordant benign breast disease are often followed closely after biopsy for a period of two years, and they are considered to be at high-risk for cancer development. Our goal was to evaluate the utility of short-term (six-month) imaging follow-up and determine the incidence of breast cancer development in this population. METHODS Retrospective review of concordant benign breast pathology was performed in 558 patients who underwent multimodality breast core biopsy. A total of 339 patients (60.7%) with 393 biopsies qualified for the study. The six-, 12-, and 24-month incidence rates of breast cancer development were estimated with 95% confidence intervals (CI), using the exact method binomial proportions. RESULTS No cancer was detected in 285 of 339 patients (84.1%) returning for the six-month follow-up. No cancer was detected in 271 of 339 patients (79.9%) returning for the 12-month follow-up. Among 207 follow-up exams (61.1%) performed at 24 months, three patients were detected to have cancer in the ipsilateral breast (1.45% [95% CI, 0.30%-4.18%]) and two patients were detected to have cancer in the contralateral breast (0.97% [95% CI, 0.12%-3.45%]). Subsequent patient biopsy rate was 30 of 339 (8.85%, [95% CI, 6.05%-12.39%]). Three ipsilateral biopsies occurred as a sole result of the six-month follow-up of 285 patients (1.05%, [95% CI, 0.22%-3.05%]). CONCLUSION Short-term imaging follow-up did not contribute to improved breast cancer detection, as all subsequent cancers were detected on annual mammography. Annual diagnostic mammography after benign breast biopsy may be sufficient.
Collapse
Affiliation(s)
- Michelle C Adams
- Advanced Imaging of Port Charlotte, Port Charlotte, Florida, USA.
| | | | | | | | | | | |
Collapse
|
22
|
Risks of Being Malignant or High Risk and Their Characteristics in Breast Lesions 20 mm or Larger After Benign Results on Ultrasonography-Guided 14-Gauge Core Needle Biopsy. Ultrasound Q 2015; 32:157-63. [PMID: 26441382 DOI: 10.1097/ruq.0000000000000179] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The malignancy risk, risk of being high-risk lesions after benign results on ultrasonography-guided 14-gauge core needle biopsies (US-CNBs), and their characteristics in breast lesions of 20 mm or greater were investigated. METHODS Eight hundred forty-seven breast lesions with benign results on US-CNB were classified as benign, high risk, and malignant through excision and clinical follow-up. The risks of being malignant or high risk were analyzed in all lesions, lesions 20 to 29 mm, and lesions 30 mm or greater. Their clinicopathological characteristics were evaluated. RESULTS Of 847, 18 (2.1%) were malignant, 53 (6.3%) were high-risk lesions, and 776 (91.6%) were benign. Of 18 malignancies, 6 (33.3%) were malignant phyllodes tumors and 12 (66.7%) were carcinomas. In benign lesions 20 to 29 mm, risks of being malignant or high risk were 1.6% (9 of 566) and 4.4% (25 of 566). In 281 lesions 30 mm or greater, the risks of being malignant or high risk were 3.2% and 10%. The risk of being high risk in lesions 30 mm or greater was 10%, significantly higher than 4.4% of lesions 20 to 29 mm (P = 0.002). CONCLUSIONS Excision can be considered in lesions measuring 20 mm or larger because of the 2.1% malignancy risk and the 6.3% risk of being high-risk lesions despite benign results on US-CNB. Excision should be considered in lesions measuring 30 mm or larger because of the 3.2% malignancy risk and the 10% risk of being high-risk lesions.
Collapse
|
23
|
Moon HJ, Jung I, Youk JH, Kim MJ, Kim EK. Short-term follow-up in 6 months is unnecessary for asymptomatic breast lesions with benign concordant results obtained at ultrasonography-guided 14-gauge core needle biopsy. Am J Surg 2015; 211:152-8. [PMID: 26381659 DOI: 10.1016/j.amjsurg.2015.03.036] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Revised: 03/10/2015] [Accepted: 03/31/2015] [Indexed: 11/29/2022]
Abstract
BACKGROUND We investigated whether short-term follow-up in 6 months was appropriate for asymptomatic benign concordant lesions on ultrasonography-guided core needle biopsy (ultrasonography-guided CNB). METHODS Of 1,111 lesions, 944 underwent follow-up within 4 to 9 months after CNB, and 359 of 944 underwent a 2nd follow-up within 9 to 15 months. One hundred sixty-seven underwent a 1st follow-up within 9 to 15 months. Follow-up intervals were classified according to an interval of 6 and 12 months with 2 different methods. First, 944 and 167 lesions were classified into the 6- and 12-month groups. Second, 944 and 526 lesions (sum of 167 and 359 lesions) were classified into the 6- and 12-month groups. Clinicopathologic factors were compared between the 2 groups. RESULTS None of the benign concordant lesions were malignant; 1.4% of the lesions showed progression in the 6-month group, not significantly different from 1.2% and .8% of the 12-month group. Mean age, mean lesion size, final assessments, and specific or nonspecific pathologies were not different between the 2 groups. CONCLUSIONS Short-term follow-up in 6 months is unnecessary for asymptomatic benign concordant breast lesions at ultrasonography-guided CNB.
Collapse
Affiliation(s)
- Hee Jung Moon
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752, Korea
| | - Inkyung Jung
- Department of Biostatistics, Yonsei University College of Medicine, Seoul, Korea
| | - Ji Hyun Youk
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752, Korea
| | - Min Jung Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752, Korea
| | - Eun-Kyung Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752, Korea.
| |
Collapse
|
24
|
Youk JH, Kim H, Kim EK, Son EJ, Kim MJ, Kim JA. Phyllodes tumor diagnosed after ultrasound-guided vacuum-assisted excision: should it be followed by surgical excision? ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:741-747. [PMID: 25619780 DOI: 10.1016/j.ultrasmedbio.2014.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Revised: 10/24/2014] [Accepted: 11/08/2014] [Indexed: 06/04/2023]
Abstract
Our aim was to retrospectively evaluate the results of ultrasound (US)-guided vacuum-assisted excision (US-VAE) of phyllodes tumors (PTs). A total of 41 PTs diagnosed at US-VAE followed by surgery (n = 27) or at least 2 y of US monitoring (n = 14) were included. By comparison of US-VAE pathology with surgical histology or follow-up US results, cases were divided into upgraded (malignant) and non-upgraded (benign) groups. These two groups were compared with respect to clinical, procedural and US features. Among 27 surgical cases, 2 (8.7%) of 23 benign PTs were upgraded to malignant PTs. The Breast Imaging Reporting and Data System category was retrospectively assigned as 4a (50%) or 4b (50%) in the upgraded group (n = 2) and 3 (64%) or 4a (36%) in the non-upgraded group (n = 39) (p = 0.018). Residual tumor was observed at the site of US-VAE in 15 of 27 surgical cases and 0 of 14 US follow-up cases (36.6%, 15/41). Given the rates of upgrade to malignancy (8.7%) and residual tumor (36.6%), PTs diagnosed after US-VAE should be surgically excised.
Collapse
Affiliation(s)
- Ji Hyun Youk
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea.
| | - Hana Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Eun-Kyung Kim
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Eun Ju Son
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Min Jung Kim
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Jeong-Ah Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
25
|
Significance of Fine Needle Aspiration Cytology and Vacuum-Assisted Core Needle Biopsy for Small Breast Lesions. Clin Breast Cancer 2015; 15:e23-6. [DOI: 10.1016/j.clbc.2014.07.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2014] [Accepted: 07/09/2014] [Indexed: 11/27/2022]
|
26
|
Dobbs J, Krishnamurthy S, Kyrish M, Benveniste AP, Yang W, Richards-Kortum R. Confocal fluorescence microscopy for rapid evaluation of invasive tumor cellularity of inflammatory breast carcinoma core needle biopsies. Breast Cancer Res Treat 2014; 149:303-10. [PMID: 25417171 PMCID: PMC4298669 DOI: 10.1007/s10549-014-3182-5] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Accepted: 10/24/2014] [Indexed: 11/27/2022]
Abstract
Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p < 0.001). Grayscale confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.
Collapse
Affiliation(s)
- Jessica Dobbs
- Department of Bioengineering, Rice University, 6500 Main Street, BRC 502, Houston, TX 77030 USA
| | - Savitri Krishnamurthy
- Department of Pathology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 1350, Houston, TX 77030 USA
| | - Matthew Kyrish
- Department of Bioengineering, Rice University, 6500 Main Street, BRC 502, Houston, TX 77030 USA
- Present Address: Fresnel Technologies, 101 West Morningside Drive, Fort Worth, TX 76110 USA
| | - Ana Paula Benveniste
- Department of Diagnostic Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 1350, Houston, TX 77030 USA
| | - Wei Yang
- Department of Diagnostic Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 1350, Houston, TX 77030 USA
| | - Rebecca Richards-Kortum
- Department of Bioengineering, Rice University, 6500 Main Street, BRC 502, Houston, TX 77030 USA
| |
Collapse
|
27
|
Sohn YM, Yoon JH, Kim EK, Moon HJ, Kim MJ. Percutaneous ultrasound-guided vacuum-assisted removal versus surgery for breast lesions showing imaging-histology discordance after ultrasound-guided core-needle biopsy. Korean J Radiol 2014; 15:697-703. [PMID: 25469080 PMCID: PMC4248624 DOI: 10.3348/kjr.2014.15.6.697] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2014] [Accepted: 09/10/2014] [Indexed: 11/15/2022] Open
Abstract
Objective To evaluate the upgrade rate and delayed false-negative results of percutaneous vacuum-assisted removal (VAR) and surgical excision in women with imaging-histologic discordance during ultrasound (US)-guided automated core needle biopsy (CNB) of the breast and to validate the role of VAR as a rebiopsy method for these discordant lesions. Materials and Methods Percutaneous US-guided 14-gauge CNB was performed on 7470 patients between August 2005 and December 2010. Our study population included 161 lesions in 152 patients who underwent subsequent rebiopsy due to imaging-histologic discordance. Rebiopsy was performed using VAR (n = 88) or surgical excision (n = 73). We investigated the upgrade rate immediately after rebiopsy and delayed false-negative results during at least 24 months of follow-up after rebiopsy. We also evaluated the clinicoradiological differences between VAR and surgical excision. Results Total upgrade to malignancy occurred in 13.7% (22/161) of lesions at rebiopsy including both VAR and surgical excision: 4.6% (4/88) of VAR cases (4/88) and 24.7% (18/73) of surgical excision cases (p < 0.001). Surgical excision was performed significantly more frequently in older patients and for larger-sized lesions than that of VAR, and a significant difference was detected between VAR and surgical excision in the Breast Imaging and Reporting and Data System category (p < 0.007). No delayed false-negative results were observed after VAR or surgical excision during the follow-up period. Conclusion Long-term follow-up data showed no delayed cancer diagnoses after US-guided VAR in imaging-histologic discordant lesions of the breast, suggesting that VAR might be a rebiopsy method for these lesions.
Collapse
Affiliation(s)
- Yu-Mee Sohn
- Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752, Korea. ; Department of Radiology, Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Seoul 130-872, Korea
| | - Jung Hyun Yoon
- Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752, Korea
| | - Eun-Kyung Kim
- Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752, Korea
| | - Hee Jung Moon
- Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752, Korea
| | - Min Jung Kim
- Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752, Korea
| |
Collapse
|
28
|
Kim YS, Park JG, Kim BS, Lee CH, Ryu DW. Diagnostic value of elastography using acoustic radiation force impulse imaging and strain ratio for breast tumors. J Breast Cancer 2014; 17:76-82. [PMID: 24744801 PMCID: PMC3988346 DOI: 10.4048/jbc.2014.17.1.76] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Accepted: 02/13/2014] [Indexed: 12/21/2022] Open
Abstract
Purpose The aim of this study was to determine whether the combination of B-mode ultrasonography (BUS), acoustic radiation force impulse (ARFI) elastography, and strain ratio (SR) provides better diagnostic performance of breast lesion differentiation than BUS alone. Methods ARFI elastography and SR evaluations were performed on patients with 157 breast lesions diagnosed by BUS from June to September 2013. BUS images were classified according to the Breast Imaging-Reporting and Data System. ARFI elastography was performed using Virtual Touch™ tissue imaging (VTI) and Virtual Touch™ tissue quantification (VTQ). In VTI mode, we evaluated the color-mapped patterns of the breast lesion and surrounding tissue. The lesions were classified into five categories by elasticity score. In VTQ mode, each lesion was assessed using shear wave velocity (SWV) measurements. SR was calculated from the lesion and comparable lateral fatty tissue. We compared the diagnostic performance of BUS alone and the combination of BUS, ARFI elastography, and SR evaluations. Results Among the 157 lesions, 40 were malignant and 117 were benign. The mean elasticity score (3.7±1.0 vs. 1.6±0.8, p<0.01), SWV (4.23±1.09 m/sec vs. 2.22±0.88 m/sec, p<0.01), and SR (5.69±1.63 vs. 2.69±1.40, p<0.01) were significantly higher for malignant lesions than benign lesions. The results for BUS combined with ARFI elastography and SR values were 97.5% sensitivity, 92.3% specificity, 93.6% accuracy, a 79.6% positive predictive value (PPV), and a 99.1% negative predictive value. The combination of the 3 radiologic examinations yielded superior specificity, accuracy, and PPV compared to BUS alone (p<0.01 for each). Conclusion ARFI elastography and SR evaluations showed significantly different mean values for benign and malignant lesions. Moreover, these two modalities complemented BUS and improved the diagnostic performance of breast lesion detection. Therefore, ARFI elastography and SR evaluations can be used as complementary modalities to make more accurate breast lesion diagnoses.
Collapse
Affiliation(s)
- Yoon Seok Kim
- Department of Surgery, Kosin University Gospel Hospital, Busan, Korea
| | - Jung Gu Park
- Department of Radiology, Kosin University Gospel Hospital, Busan, Korea
| | - Beom Su Kim
- Department of Radiology, Kosin University Gospel Hospital, Busan, Korea
| | - Chung Han Lee
- Department of Surgery, Kosin University Gospel Hospital, Busan, Korea
| | - Dong Won Ryu
- Department of Surgery, Kosin University Gospel Hospital, Busan, Korea
| |
Collapse
|
29
|
Zhou JY, Tang J, Wang ZL, Lv FQ, Luo YK, Qin HZ, Liu M. Accuracy of 16/18G core needle biopsy for ultrasound-visible breast lesions. World J Surg Oncol 2014; 12:7. [PMID: 24400744 PMCID: PMC3895748 DOI: 10.1186/1477-7819-12-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Accepted: 12/27/2013] [Indexed: 11/27/2022] Open
Abstract
Background To assess the accuracy of ultrasound-guided 16G or 18G core needle biopsy (CNB) for ultrasound-visible breast lesions, and to analyze the effects of lesion features. Methods Between July 2005 and July 2012, 4,453 ultrasound-detected breast lesions underwent ultrasound-guided CNB and were retrospectively reviewed. Surgical excision was performed for 955 lesions (566 with 16G CNB and 389 with 18G CNB) which constitute the basis of the study. Histological findings were compared between the ultrasound-guided CNB and the surgical excision to determine sensitivity, false-negative rate, agreement rate, and underestimation rate, according to different lesion features. Results Final pathological results were malignant in 84.1% (invasive carcinoma, ductal carcinoma in situ, lymphoma, and metastases), high-risk in 8.4% (atypical lesions, papillary lesions, and phyllodes tumors), and benign in 7.5%. False-negative rates were 1.4% for 16G and 18G CNB. Agreement rates between histological findings of CNB and surgery were 92.4% for 16G and 92.8% for 18G CNB. Overall underestimate rates (high-risk CNB becoming malignant on surgery and ductal carcinoma in situ becoming invasive carcinoma) were 47.4% for 16G and 48.9% for 18G CNB. Agreements were better for mass lesions (16G: 92.7%; 18G: 93.7%) than for non-mass lesions (16G, 85.7%; 18G, 78.3%) (P <0.01). For mass lesions with a diameter ≤10 mm, the agreement rates (16G, 83.3%; 18G, 86.7%) were lower (P <0.01). Conclusions Ultrasound-guided 16G and 18G CNB are accurate for evaluating ultrasound-visible breast mass lesions with a diameter >10 mm.
Collapse
Affiliation(s)
| | - Jie Tang
- Department of Ultrasound, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853, China.
| | | | | | | | | | | |
Collapse
|
30
|
Qualitative pattern classification of shear wave elastography for breast masses: How it correlates to quantitative measurements. Eur J Radiol 2013; 82:2199-204. [DOI: 10.1016/j.ejrad.2013.08.047] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 07/29/2013] [Accepted: 08/23/2013] [Indexed: 12/15/2022]
|
31
|
Abstract
Ultrasonography (US) is an indispensable tool in breast imaging and is complementary to both mammography and magnetic resonance (MR) imaging of the breast. Advances in US technology allow confident characterization of not only benign cysts but also benign and malignant solid masses. Knowledge and understanding of current and emerging US technology, along with the application of meticulous scanning technique, is imperative for image optimization and diagnosis. The ability to synthesize breast US findings with multiple imaging modalities and clinical information is also necessary to ensure the best patient care. US is routinely used to guide breast biopsies and is also emerging as a supplemental screening tool in women with dense breasts and a negative mammogram. This review provides a summary of current state-of-the-art US technology, including elastography, and applications of US in clinical practice as an adjuvant technique to mammography, MR imaging, and the clinical breast examination. The use of breast US for screening, preoperative staging for breast cancer, and breast intervention will also be discussed.
Collapse
Affiliation(s)
- Regina J Hooley
- Department of Diagnostic Radiology, Yale University School of Medicine, 333 Cedar St, PO Box 208042, New Haven, CT 06520-8042, USA.
| | | | | |
Collapse
|
32
|
Rouse HC, Ussher S, Kavanagh AM, Cawson JN. Examining the sensitivity of ultrasound-guided large core biopsy for invasive breast carcinoma in a population screening programme. J Med Imaging Radiat Oncol 2013; 57:435-43. [PMID: 23870339 DOI: 10.1111/1754-9485.12050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2012] [Accepted: 12/20/2013] [Indexed: 10/27/2022]
Abstract
INTRODUCTION To evaluate the sensitivity of ultrasound-guided core-needle biopsy (UCB) in invasive breast carcinoma and to establish causes of false-negative biopsy in a population screening programme. METHOD We identified 571 consecutive women diagnosed with surgically proven invasive breast cancer. Histology from 14-gauge UCB was compared with surgical histology to identify true-positive and false-negative ultrasound core biopsies. True-positive and false-negative groups were compared for tumour size and histology. On blinded review of UCB images and pathology reports from false negative (n = 20) and a random sample of true-positive cases (n = 80), we compared core sample number and needle visualisation in the lesion. RESULTS Of 571 carcinomas sampled with UCB, 551 (96.5%) were true positive and 20 (3.5%) were false negative. The mean core number was 2.0 (range 1-3) for false negatives and 2.25 (range 1-4) for true positives (P = 0.27). Mean tumour sizes were 13.3 and 16.2 mm for the false-negative and true-positive groups, respectively (P = 0.25). Tubular carcinomas represented 30% (6/20) of false-negative cases compared with 5.1% (28/551) of the true-positive cases (P < 0.001). On blinded review, needle visualisation within the lesion was demonstrated in 47.4% (9/19) of false-negative cases and 76.3% (61/80) of true-positive cases (P = 0.02). CONCLUSION We demonstrated a sensitivity of 96.5% with a mean of 2.21 cores. False-negative results were more likely in the absence of post-fire needle position verification and with tubular carcinomas. Neither tumour size nor core number predicted diagnostic accuracy.
Collapse
Affiliation(s)
- Hannah C Rouse
- St Vincent's Breast Screen, St Vincent's Hospital Campus
| | | | | | | |
Collapse
|
33
|
Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results? Eur Radiol 2013; 23:2432-40. [PMID: 23673572 DOI: 10.1007/s00330-013-2854-6] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 02/27/2013] [Accepted: 02/27/2013] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. METHODS From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. RESULTS Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P < 0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P < 0.05). All 47 malignant breast masses had SWE images of good quality. CONCLUSIONS False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. KEY POINTS • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.
Collapse
|
34
|
Lee EJ, Jung HK, Ko KH, Lee JT, Yoon JH. Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses? Eur Radiol 2013; 23:1803-11. [PMID: 23423637 DOI: 10.1007/s00330-013-2782-5] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2012] [Revised: 12/18/2012] [Accepted: 01/05/2013] [Indexed: 12/14/2022]
Abstract
OBJECTIVE To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. METHODS One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 ± 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. RESULTS Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. CONCLUSIONS Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. KEY POINTS • SWE offers new information over and above conventional breast ultrasound • Various SWE parameters were explored regarding distinction between benign and malignant lesions • An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses • However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.
Collapse
Affiliation(s)
- Eun Jung Lee
- Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine, 351 Yatapdong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-712, Korea
| | | | | | | | | |
Collapse
|
35
|
Kasprowicz N, Bauerschmitz GJ, Schönherr A, Baldus SE, Janni W, Mohrmann S. Recurrent Mastitis after Core Needle Biopsy: Case Report of an Unusual Complication after Core Needle Biopsy of a Phyllodes Tumor. Breast Care (Basel) 2012; 7:240-244. [PMID: 22872800 DOI: 10.1159/000339689] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND: In the routine work-up of suspect breast lesions, ultrasound-controlled core needle biopsy (CNB) is the most common tool to acquire tissue for histopathologic analysis in a safe, quick and convenient way. Complications are generally rare. The most common complications are hematoma and infection, each with less than 1 in 1000 cases. CASE REPORT: Here, we present a case of a 48-year-old patient who underwent CNB for several lesions that were assessed as Breast Imaging Report and Data System (BI-RADS) IV in breast ultrasound and mammography. In the past, she had had 2 bilateral breast reduction surgeries and 1 open biopsy of a fibroadenoma. Histology revealed a phyllodes tumor. Following this, mastitis occurred which was resistant to common conservative measurements such as intravenous antibiotics over months. Finally, mastectomy was performed, followed by adequate wound healing. CONCLUSIONS: In the presented case, the prolonged course of breast infection after CNB was not as expected. If this occurs, conservative treatment with antibiotics can be initiated. Possible additional risk factors such as diabetes mellitus, steroid therapy, or immunosuppression should be identified. However, in case of missing recovery, wide surgical excision is recommended.
Collapse
Affiliation(s)
- Nikola Kasprowicz
- Breast Center, Department of Gynecology and Obstetrics, Düsseldorf University Hospital, Germany
| | | | | | | | | | | |
Collapse
|
36
|
|
37
|
Youk JH, Jung I, Kim EK, Kim MJ, Son EJ, Moon HJ, Kwak JY. US follow-up protocol in concordant benign result after US-guided 14-gauge core needle breast biopsy. Breast Cancer Res Treat 2012; 132:1089-97. [PMID: 22218886 DOI: 10.1007/s10549-011-1951-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2011] [Accepted: 12/28/2011] [Indexed: 11/30/2022]
Abstract
To determine the time when follow-up ultrasound (US) should begin for concordant benign lesions after US-guided 14-gauge core needle breast biopsy (CNB). This was an IRB-approved retrospective study, with a waiver of informed consent. Among 3,888 consecutive US-guided CNBs performed between August 2005 and March 2008, 1,492 breast masses in 1,309 women with concordant benign results and follow-up US after CNB were included. Their medical records were reviewed. Statistical comparisons for the result of first follow-up US and malignant rates among 6-month, 12-month, and long-term intervals were performed by using Fisher exact test. Results dichotomized for symptom, lesion size (10 mm), and CNB result (specific or not), were also analyzed. In 1,492 masses, seven malignancies (0.5%) were diagnosed by interval growth at first follow-up US performed at 6-month (n = 3), 12-month (n = 1), and long-term interval (n = 3). No significant difference in results of follow-up US and malignant rates was found among follow-up intervals. At 6-month interval, malignant rate in symptomatic group (1.9%, 3/162) was significantly higher than in asymptomatic group (0%, 0/819) (P = 0.004). The size of malignancy at long-term interval tended to be larger than at shorter interval, and metastasis was developed in one patient with malignancy at long-term interval. Concordant benign lesions after US-guided 14-gauge CNB should be recommended to begin US follow-up at least at 12 months to detect early-stage cancers. However, for concordant benign lesion associated with any clinical symptoms, follow-up US should begin earlier, at 6 months after CNB.
Collapse
Affiliation(s)
- Ji Hyun Youk
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seodaemun-ku, Shinchon-dong 134, Seoul 120-752, South Korea
| | | | | | | | | | | | | |
Collapse
|
38
|
Pagni F, Bosisio FM, Salvioni D, Colombo P, Leone BE, Di Bella C. Application of the British National Health Service Breast Cancer Screening Programme classification in 226 breast core needle biopsies: correlation with resected specimens. Ann Diagn Pathol 2011; 16:112-8. [PMID: 22056037 DOI: 10.1016/j.anndiagpath.2011.08.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2011] [Revised: 08/08/2011] [Accepted: 08/08/2011] [Indexed: 10/15/2022]
Abstract
A retrospective study correlating the diagnosis made on core needle breast biopsy (CNB) with the diagnosis made on the final surgical specimen was done using the British National Health Service Breast Cancer Screening Programme (NHSBSP) classification for CNB on 226 patients during a period of 15 months. Statistical analysis was used to evaluate sensitivity, specificity, and positive and negative predictive values of the NHSBSP diagnostic categories. Cohen κ was used to evaluate the agreement between the diagnosis on CNB and the final pathologic diagnosis in "clinically positive cases." Finally, a comparative analysis between the CNB method and fine needle aspiration biopsy was made. The distribution of our cases for each diagnostic category reflects the literature guidelines, with minor differences in the B2 and B4 groups. Statistical data about the patients' follow-up revealed a small number of false-negative cases in the B1 and B2 categories and no false-positive cases in the B4 and B5 groups. Uncertain malignant lesions (B3 category) were divided into 3 major areas (papillary lesions, fibroepithelial proliferations with cellular stroma, and intraepithelial atypical lesions such as ductal intraepithelial neoplasia grade 1/lobular intraepithelial neoplasia grade 1). Of the 29 patients in the B3 category, 26 underwent surgery. Cohen κ analysis showed a strong statistical correlation (κ = 0.77; Z = 4.3; significance >1.96; α = .05) between CNB diagnosis and surgical pathology final results in the subgroup of high-risk patients (diagnosis, ≥ductal intraepithelial neoplasia grade 1 on CNB). Global diagnostic power of CNB in all 226 cases revealed high sensitivity (88.3%) and slightly lower specificity (72.8%). In 42 "doubtful" cases, synchronous fine needle aspiration biopsy and CNB were performed, showing a complementary role in the diagnostic phase of breast lesions. Core needle breast biopsy represents the criterion standard method in the diagnostic phase of many breast tumors; the NHSBSP classification is a useful reporting system that provides a good standardization of the pathologic diagnosis and provides a clear guideline for the correct management of the patient.
Collapse
Affiliation(s)
- Fabio Pagni
- Department of Pathology, Azienda Ospedaliera Ospedale di Vimercate-Desio, Italy.
| | | | | | | | | | | |
Collapse
|
39
|
Son EJ, Kim EK, Youk JH, Kim MJ, Kwak JY, Choi SH. Imaging-histologic discordance after sonographically guided percutaneous breast biopsy: a prospective observational study. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:1771-1778. [PMID: 21856068 DOI: 10.1016/j.ultrasmedbio.2011.07.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2011] [Revised: 07/11/2011] [Accepted: 07/18/2011] [Indexed: 05/31/2023]
Abstract
The objective of this study was to determine the frequency of imaging-histologic discordance and to compare the frequency of carcinoma between concordant and discordant lesions in sonographically (US)-guided 14-gauge core needle biopsies (CNBs). From January 2005 to December 2006, we performed US-guided 14-gauge automated CNB on 3339 breast lesions and obtained benign results in 2194 cases. Five radiologists prospectively reviewed the pathologic reports in conjunction with the imaging. We included a total of 1588 lesions that were either excised (n = 658) or followed up for at least 2 years (n = 930) after CNB. We evaluated the rate of discordance and the clinical findings for both discordant and concordant lesions. We also analyzed the clinical and imaging differences between the upgrade and non-upgrade groups. Imaging-histologic discordance was present in 103 of 1588 (6.5%) lesions. The upgrade rate was 6.8% (7/103) in discordant lesions and 0.4% (6/1485) in concordant lesions (p < 0.01). Lesion size, Breast Imaging, Reporting and Data System (BI-RADS) category and the presence or absence of symptoms was statistically significant between the upgrade and non-upgrade groups in discordant cases (p < .05). Imaging-histologic discordance is an indication for excision because it has a higher upgrade rate than concordant lesions.
Collapse
Affiliation(s)
- Eun Ju Son
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, South Korea
| | | | | | | | | | | |
Collapse
|
40
|
Youk JH, Kim MJ, Son EJ, Kwak JY, Kim EK. US-guided vacuum-assisted percutaneous excision for management of benign papilloma without atypia diagnosed at US-guided 14-gauge core needle biopsy. Ann Surg Oncol 2011; 19:922-8. [PMID: 21863359 DOI: 10.1245/s10434-011-2033-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2011] [Indexed: 11/18/2022]
Abstract
PURPOSE To assess the diagnostic accuracy of ultrasound (US)-guided vacuum-assisted excision (VAE) for the postbiopsy management of benign papilloma without atypia after US-guided 14-gauge core needle biopsy (CNB). METHODS This was an institutional review board-approved retrospective study, with a waiver of informed consent. After a review of the histologic results and postbiopsy management of US-guided CNB performed from January 2007 through April 2009, 122 benign papillomas without atypia were diagnosed at CNB and excised percutaneously with US-guided VAE. Among them, a total of 67 papillomas having surgical excision (n = 5) or at least 2 years' US follow-up (n = 62) after VAE were enrolled onto this study. We reviewed the medical records, US findings, and pathologic results obtained before and after VAE. Over the follow-up period, whether any malignancy at the site of the VAE was diagnosed was evaluated. RESULTS The pathologic results of 67 VAEs were benign in 63 (94%) and atypical in four (6%). None of 63 benign lesions proved to be malignant after surgical excision (n = 1) or US follow-up (n = 62). Of four atypical lesions, however, one was upgraded to ductal carcinoma-in-situ (25%) after surgical excision. Of 62 benign VAE results having US follow-up, 56 (90.3%) showed no residual lesion at the site of the VAE. CONCLUSIONS For the postbiopsy management of benign papilloma without atypia after US-guided CNB, US-guided VAE was accurate and could be alternative to surgery. In cases of diagnosis of atypical lesion at VAE, however, surgery should be performed for a definitive diagnosis.
Collapse
Affiliation(s)
- Ji Hyun Youk
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, South Korea
| | | | | | | | | |
Collapse
|
41
|
Povoski SP, Jimenez RE, Wang WP. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach. World J Surg Oncol 2011; 9:87. [PMID: 21835024 PMCID: PMC3171710 DOI: 10.1186/1477-7819-9-87] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2011] [Accepted: 08/11/2011] [Indexed: 11/12/2022] Open
Abstract
Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.
Collapse
Affiliation(s)
- Stephen P Povoski
- Division of Surgical Oncology, Department of Surgery, Arthur G, James Cancer Hospital and Richard J, Solove Research Institute and Comprehensive Cancer Center, The Ohio State University, Columbus, Ohio 43210, USA.
| | | | | |
Collapse
|
42
|
Ultrasound-guided core-needle biopsy of breast lesions. Insights Imaging 2011; 2:493-500. [PMID: 22347970 PMCID: PMC3259303 DOI: 10.1007/s13244-011-0090-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2010] [Revised: 12/24/2010] [Accepted: 03/17/2011] [Indexed: 12/11/2022] Open
Abstract
Objective To review the role of ultrasound-guided core-needle biopsy (CNB) in the management of breast lesions. Methods Review of the most relevant literature on this topic. Results This technique shows a high sensitivity value of about 97.5% and it offers many advantages over other imaging techniques to guide a biopsy: non-ionising radiation, low cost, full control of the needle in real time, accessibility in difficult locations, multidirectional punctures and excellent comfort for patients and radiologists. All of these advantages have made this technique the most widespread used to perform a biopsy for a suspicious breast lesion. The most important limitation is the failure to perform a biopsy for lesions that are not seen on ultrasound. An adequate radiological–pathological correlation is necessary to minimise the false-negative results. Conclusion Ultrasound-guided CNB has proven to be a reliable technique for performing a biopsy for breast lesions that can be clearly seen on ultrasound.
Collapse
|
43
|
Molleran V. Postbiopsy management. Semin Roentgenol 2010; 46:40-50. [PMID: 21134527 DOI: 10.1053/j.ro.2010.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Virginia Molleran
- Breast Imaging Department, UC Health/University Hospital, Cincinnati, OH, USA.
| |
Collapse
|
44
|
Youk JH, Kim EK, Kwak JY, Son EJ, Park BW, Kim SI. Benign papilloma without atypia diagnosed at US-guided 14-gauge core-needle biopsy: clinical and US features predictive of upgrade to malignancy. Radiology 2010; 258:81-8. [PMID: 20971773 DOI: 10.1148/radiol.10100728] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the diagnostic accuracy of ultrasonographically (US)-guided 14-gauge core-needle biopsy (CNB) for benign papilloma without atypia and to determine whether clinical and radiologic features could be used to predict an upgrade to malignancy. MATERIALS AND METHODS This was an institutional review board-approved retrospective study, with a waiver of informed consent. The histologic results of US-guided CNB procedures performed from January 2006 through January 2009 were reviewed. A total of 160 benign papillomas without atypia that were diagnosed at CNB and excised surgically in 143 women (age range, 19-77 years) were assessed. Medical records and sonograms in the women were reviewed. Two radiologists working in consensus correlated imaging findings with the biopsy result to determine concordance. For the upgrade to malignancy after excision, malignant lesions were compared with nonmalignant lesions for the collected clinical and radiologic variables, which included patient age, lesion size, and lesion distance from the nipple, by using the χ(2) or Fisher exact test for categoric variables and the Mann-Whitney U test for continuous variables. RESULTS Eight (5.0%) of 160 papillomas were upgraded to malignancy. Lesions that were 1 cm or larger (seven [11%] of 63) showed a higher upgrade rate than lesions that were smaller than 1 cm (one [1%] of 97) (P = .006). The upgrade rate was higher in patients aged 50 years or older (six [16%] of 37) than in patients younger than 50 years (two [2%] of 123) (P = .002). Lesions that were 3 cm or farther from the nipple (four [13%] of 31) showed a higher upgrade rate than lesions that were less than 3 cm from the nipple (four [3.1%] of 129) (P = .046). Upgrade rates for Breast Imaging Reporting and Data System (BI-RADS) category 3, 4a, 4b, 4c, and 5 lesions were 0%, 2.5%, 6%, 27%, and 25%, respectively (P = .010). CONCLUSION At US-guided 14-gauge CNB, benign papilloma without atypia could be diagnosed accurately. Discordance between imaging and pathology results, as well as patient age of 50 years or older, lesion size of 1 cm or greater, lesion distance from the nipple of 3 cm or greater, and BI-RADS category may be helpful in predicting the possibility of upgrade to malignancy.
Collapse
Affiliation(s)
- Ji Hyun Youk
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Shinchon-dong 134, Seodaemun-ku, Seoul 120-752, South Korea
| | | | | | | | | | | |
Collapse
|
45
|
Rakha EA, Lee AHS, Reed J, Murphy A, El-Sayed M, Burrell H, Evans AJ, Ellis IO. Screen-detected malignant breast lesions diagnosed following benign (B2) or normal (B1) needle core biopsy diagnoses. Eur J Cancer 2010; 46:1835-40. [PMID: 20392631 DOI: 10.1016/j.ejca.2010.03.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2009] [Revised: 02/26/2010] [Accepted: 03/22/2010] [Indexed: 11/24/2022]
Abstract
UNLABELLED Breast needle core biopsy (NCB) is now a standard diagnostic procedure in the triple assessment of screen detected breast lesions. However, unlike fine needle aspiration (FNA) cytology, information on the miss rate including false-negative diagnoses (FN) of malignancy (benign 'B2' or normal 'B1' NCB with a malignant outcome) is limited. METHODS A large series of NCBs (121,742) performed over an 8-year period has been studied to assess the frequency and causes of missing a malignant diagnosis on NCB and to evaluate their impact on patients' management in the screening service. RESULTS During the period of this study, 50,691 were diagnosed as B2 and 9599 were diagnosed as B1. Of those, 779 B2 and 919 B1 were diagnosed as malignant on the subsequent surgical specimens, respectively, giving a FN rate of 3.0%. However when year of diagnosis was taken into consideration, we found that during the period 1999-2001, the FN rate for B2 was 2.7% while the miss rate for B1 was 4.0%. This showed marked improvement over time to reach a figure of 0.5% and 0.5% for B2 and B1, respectively, during the period 2005-2007. On detailed review of cases from a single screening region diagnosed during the last 3 years (2005-2008), 14 cases (0.17% of all NCBs) with malignant surgery were diagnosed as B2 (seven cases; FN rate 0.19%) and B1 (seven cases; B1 biopsy rate from cancer 0.19%). In these cases, NCB was unsatisfactory, there was a discrepancy between radiological abnormalities and histological findings with recommendation for excision or suspicious/malignant cytological diagnosis on concurrent FNA material. Therefore, our results indicate that the malignancy miss rate on NCB is rare and FN NCB diagnoses had no impact on patient management.
Collapse
Affiliation(s)
- Emad A Rakha
- Department of Histopathology, Nottingham University Hospitals NHS Trust, Nottingham City Hospital, Nottingham NG5 1PB, UK.
| | | | | | | | | | | | | | | |
Collapse
|