1
|
Wagner WL, Föhst S, Hock J, Kim YO, Popov Y, Schuppan D, Schladitz K, Redenbach C, Ackermann M. 3D analysis of microvasculature in murine liver fibrosis models using synchrotron radiation-based microtomography. Angiogenesis 2021; 24:57-65. [PMID: 33037487 PMCID: PMC7920893 DOI: 10.1007/s10456-020-09751-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 09/28/2020] [Indexed: 12/16/2022]
Abstract
Cirrhosis describes the development of excess fibrous tissue around regenerative nodules in response to chronic liver injury and usually leads to irreversible organ damage and end-stage liver disease. During the development of cirrhosis, the formation of collagenous scar tissue is paralleled by a reorganization and remodeling of the hepatic vascular system. To date, macrovascular remodeling in various cirrhosis models has been examined using three-dimensional (3D) imaging modalities, while microvascular changes have been studied mainly by two-dimensional (2D) light microscopic and electron microscopic imaging. Here, we report on the application of high-resolution 3D synchrotron radiation-based microtomography (SRμCT) for the study of the sinusoidal and capillary blood vessel system in three murine models of advanced parenchymal and biliary hepatic fibrosis. SRμCT facilitates the characterization of microvascular architecture and identifies features of intussusceptive angiogenesis in progressive liver fibrosis in a non-destructive 3D manner.
Collapse
Affiliation(s)
- Willi L Wagner
- Department of Diagnostic and Interventional Radiology, University of Heidelberg, Heidelberg, Germany
- Translational Lung Research Center, Member of the German Center for Lung Research, University of Heidelberg, Heidelberg, Germany
| | - Sonja Föhst
- Mathematics Department, Technische Universität Kaiserslautern, Kaiserslautern, Germany
| | - Jessica Hock
- Institute of Functional and Clinical Anatomy, University Medical Center of the Johannes Gutenberg-University Mainz, Johann-Joachim-Becher-Weg 13, 55128, Mainz, Germany
| | - Yong Ook Kim
- Institute of Translational Immunology and Research Center for Immune Therapy (FZI), University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Yury Popov
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Detlef Schuppan
- Institute of Translational Immunology and Research Center for Immune Therapy (FZI), University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Katja Schladitz
- Image Processing Department, Fraunhofer ITWM, Kaiserslautern, Germany
| | - Claudia Redenbach
- Mathematics Department, Technische Universität Kaiserslautern, Kaiserslautern, Germany
| | - Maximilian Ackermann
- Institute of Functional and Clinical Anatomy, University Medical Center of the Johannes Gutenberg-University Mainz, Johann-Joachim-Becher-Weg 13, 55128, Mainz, Germany.
- Institute of Pathology and Molecular Pathology, Helios University Clinic Wuppertal, University of Witten-Herdecke, Wuppertal, Germany.
| |
Collapse
|
2
|
Convolutional neuronal networks combined with X-ray phase-contrast imaging for a fast and observer-independent discrimination of cartilage and liver diseases stages. Sci Rep 2020; 10:20007. [PMID: 33203975 PMCID: PMC7673137 DOI: 10.1038/s41598-020-76937-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Accepted: 10/27/2020] [Indexed: 12/19/2022] Open
Abstract
We applied transfer learning using Convolutional Neuronal Networks to high resolution X-ray phase contrast computed tomography datasets and tested the potential of the systems to accurately classify Computed Tomography images of different stages of two diseases, i.e. osteoarthritis and liver fibrosis. The purpose is to identify a time-effective and observer-independent methodology to identify pathological conditions. Propagation-based X-ray phase contrast imaging WAS used with polychromatic X-rays to obtain a 3D visualization of 4 human cartilage plugs and 6 rat liver samples with a voxel size of 0.7 × 0.7 × 0.7 µm3 and 2.2 × 2.2 × 2.2 µm3, respectively. Images with a size of 224 × 224 pixels are used to train three pre-trained convolutional neuronal networks for data classification, which are the VGG16, the Inception V3, and the Xception networks. We evaluated the performance of the three systems in terms of classification accuracy and studied the effect of the variation of the number of inputs, training images and of iterations. The VGG16 network provides the highest classification accuracy when the training and the validation-test of the network are performed using data from the same samples for both the cartilage (99.8%) and the liver (95.5%) datasets. The Inception V3 and Xception networks achieve an accuracy of 84.7% (43.1%) and of 72.6% (53.7%), respectively, for the cartilage (liver) images. By using data from different samples for the training and validation-test processes, the Xception network provided the highest test accuracy for the cartilage dataset (75.7%), while for the liver dataset the VGG16 network gave the best results (75.4%). By using convolutional neuronal networks we show that it is possible to classify large datasets of biomedical images in less than 25 min on a 8 CPU processor machine providing a precise, robust, fast and observer-independent method for the discrimination/classification of different stages of osteoarthritis and liver diseases.
Collapse
|
3
|
Synchrotron Radiation-Based Three-Dimensional Visualization of Angioarchitectural Remodeling in Hippocampus of Epileptic Rats. Neurosci Bull 2019; 36:333-345. [PMID: 31823302 DOI: 10.1007/s12264-019-00450-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 09/11/2019] [Indexed: 12/15/2022] Open
Abstract
Characterizing the three-dimensional (3D) morphological alterations of microvessels under both normal and seizure conditions is crucial for a better understanding of epilepsy. However, conventional imaging techniques cannot detect microvessels on micron/sub-micron scales without angiography. In this study, synchrotron radiation (SR)-based X-ray in-line phase-contrast imaging (ILPCI) and quantitative 3D characterization were used to acquire high-resolution, high-contrast images of rat brain tissue under both normal and seizure conditions. The number of blood microvessels was markedly increased on days 1 and 14, but decreased on day 60 after seizures. The surface area, diameter distribution, mean tortuosity, and number of bifurcations and network segments also showed similar trends. These pathological changes were confirmed by histological tests. Thus, SR-based ILPCI provides systematic and detailed views of cerebrovascular anatomy at the micron level without using contrast-enhancing agents. This holds considerable promise for better diagnosis and understanding of the pathogenesis and development of epilepsy.
Collapse
|
4
|
Qin L, Zhao X, Jian J, Zhao Y, Sun M, Hu C. High-resolution 3D visualization of ductular proliferation of bile duct ligation-induced liver fibrosis in rats using x-ray phase contrast computed tomography. Sci Rep 2017; 7:4215. [PMID: 28652608 PMCID: PMC5484700 DOI: 10.1038/s41598-017-03993-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Accepted: 05/08/2017] [Indexed: 12/18/2022] Open
Abstract
X-ray phase-contrast computed tomography (PCCT) can provide excellent image contrast for soft tissues with small density differences, and it is particularly appropriate for three-dimensional (3D) visualization of accurate microstructures inside biological samples. In this study, the morphological structures of proliferative bile ductules (BDs) were visualized without contrast agents via PCCT with liver fibrosis samples induced by bile duct ligation (BDL) in rats. Adult male Sprague-Dawley rats were randomly divided into three groups: sham operation group, 2-week and 6-week post-BDL groups. All livers were removed after euthanasia for a subsequent imaging. The verification of the ductular structures captured by PCCT was achieved by a careful head-to-head comparison with their corresponding histological images. Our experimental results demonstrated that PCCT images corresponded very well to the proliferative BDs shown by histological staining using cytokeratin 19 (CK19). Furthermore, the 3D density of proliferative BDs increased with the progression of liver fibrosis. In addition, PCCT accurately revealed the architecture of proliferative BDs in a 3D fashion, including the ductular ramification, the elongation and tortuosity of the branches, and the corrugations of the luminal duct surface. Thus, the high-resolution PCCT technique can improve our understanding of the characteristics of ductular proliferation from a new 3D perspective.
Collapse
Affiliation(s)
- Lili Qin
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, 300070, China
| | - Xinyan Zhao
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China
| | - Jianbo Jian
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, 300070, China
| | - Yuqing Zhao
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, 300070, China
| | - Mengyu Sun
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, 300070, China
| | - Chunhong Hu
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, 300070, China.
| |
Collapse
|
5
|
Li B, Zhang Y, Wu W, Du G, Cai L, Shi H, Chen S. Neovascularization of hepatocellular carcinoma in a nude mouse orthotopic liver cancer model: a morphological study using X-ray in-line phase-contrast imaging. BMC Cancer 2017; 17:73. [PMID: 28122521 PMCID: PMC5264465 DOI: 10.1186/s12885-017-3073-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2016] [Accepted: 01/18/2017] [Indexed: 11/24/2022] Open
Abstract
Background This study aimed to determine whether synchrotron radiation (SR)-based X-ray in-line phase-contrast imaging (IL-PCI) can be used to investigate the morphological characteristics of tumor neovascularization in a liver xenograft animal model. Methods A human hepatocellular carcinoma HCCLM3 xenograft model was established in nude mice. Xenografts were sampled each week for 4 weeks and fixed to analyze tissue characteristics and neovascularization using SR-based X-ray in-line phase contrast computed tomography (IL-XPCT) without any contrast agent. Results The effect of the energy level and object–to-detector distance on phase-contrast difference was in good agreement with the theory of IL-PCI. Boundaries between the tumor and adjacent normal tissues at week 1 were clearly observed in two-dimensional phase contrast projection imaging. A quantitative contrast difference was observed from weeks 1 to 4. Moreover, 3D image reconstruction of hepatocellular carcinoma (HCC) samples showed blood vessels inside the tumor were abnormal. The smallest blood vessels measured approximately 20 μm in diameter. The tumor vascular density initially increased and then decreased gradually over time. The maximum tumor vascular density was 4.29% at week 2. Conclusion IL-XPCT successfully acquired images of neovascularization in HCC xenografts in nude mice.
Collapse
Affiliation(s)
- Beilei Li
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Yiqiu Zhang
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Weizhong Wu
- Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Guohao Du
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201800, China
| | - Liang Cai
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Shaoliang Chen
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China. .,Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
| |
Collapse
|
6
|
Jian J, Zhang W, Yang H, Zhao X, Xuan R, Li D, Hu C. Phase-contrast CT: Qualitative and Quantitative Evaluation of Capillarized Sinusoids and Trabecular Structure in Human Hepatocellular Carcinoma Tissues. Acad Radiol 2017; 24:67-75. [PMID: 27818006 DOI: 10.1016/j.acra.2016.08.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 08/14/2016] [Accepted: 08/25/2016] [Indexed: 12/17/2022]
Abstract
RATIONALE AND OBJECTIVES Capillarization of sinusoids and change of trabecular thickness are the main histologic features in hepatocellular carcinoma (HCC). Of particular interest are the three-dimensional (3D) visualization and quantitative evaluation of such alterations in the HCC progression. X-ray phase-contrast computed tomography (PCCT) is an emerging imaging method that provides excellent image contrast for soft tissues. This study aimed to explore the potential of in-line PCCT in microstructure imaging of capillarized sinusoids and trabecular structure in human HCC tissues and to quantitatively evaluate the alterations of those fine structures during the development of HCC. MATERIALS AND METHODS This project was designed as an ex vivo experimental study. The study was approved by the institutional review board, and informed consent was obtained from the patients. Eight human resected HCC tissue samples were imaged using in-line PCCT. After histologic processing, PCCT images and histopathologic data were matched. Fine structures in HCC tissues were revealed. Quantitative analyses of capillarized sinusoids (ie, percentage of sinusoidal area [PSA], sinusoidal volume) and trabecular structure (ie, trabecular thickness, surface-area-to-volume ratio [SA/V]) in low-grade (well or moderately differentiated) and high-grade (poorly differentiated) HCC groups were performed. RESULTS Using PCCT, the alterations of capillarized sinusoids and trabecular structure were clearly observed in 3D geometry, which was confirmed by the corresponding histologic sections. The 3D qualitative analyses of sinusoids in the high-grade HCC group were significantly different (P < 0.05) in PSA (7.8 ± 2.5%) and sinusoidal volume (2.9 ± 0.6 × 107 µm3) from those in the low-grade HCC group (PSA, 12.9 ± 2.2%; sinusoidal volume, 2.4 ± 0.3 × 107 µm3). Moreover, the 3D quantitative evaluation of the trabecular structure in the high-grade HCC group showed a significant change (P < 0.05) in the trabecular thickness (87.8 ± 15.6 µm) and SA/V (2.2 ± 1.3 × 103 µm-1) compared to the low-grade HCC group (trabecular thickness, 75.9 ± 7.1 µm; SA/V, 7.5 ± 1.3 × 103 µm-1). CONCLUSIONS This study provides insights into the 3D alterations of microstructures such as capillarized sinusoids and the trabecular structure at a micrometer level, which might allow for an improved understanding of the development of HCC.
Collapse
|
7
|
A Novel and Sensitive Approach for the Evaluation of Liver Ischemia-Reperfusion Injury After Liver Transplantation. Invest Radiol 2016; 51:170-6. [PMID: 26488374 DOI: 10.1097/rli.0000000000000220] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
OBJECTIVES The purpose of our study was to evaluate the potential of x-ray propagation-based phase-contrast imaging (PCI) computed tomography (CT) for the detection and characterization of early changes after ischemia-reperfusion (IR) in a standardized rat liver transplantation (LTx) model. MATERIALS AND METHODS Syngeneic orthotopic liver transplantation was performed in male Lewis rats. Ischemia-reperfusion injury (IRI)-induced changes of liver parenchyma were investigated in a time-dependent manner (2, 16, 24, and 32 hours). X-ray phase-contrast images of formalin-fixated liver specimens were acquired in CT mode by using a voxel size of 8 × 8 × 8 μm. Necrapoptotic cell death was visualized with the TdT-mediated dUTP-biotin nick end labeling technique, and alterations of liver graft microhemodynamics, that is, acinar and sinusoidal perfusion failure, were evaluated by in vivo fluorescence microscopy. RESULTS Acquired and reconstructed PCI-CT images showed an increase in necrotic liver parenchyma dependent on cold storage time, measuring 5.7% ± 1.6% after 2 hours (comparable to 2.6% ± 0.4% for sham livers), 11.5% ± 2.1% (16 hours; P < 0.05 vs control), 23.0% ± 0.5% (24 hours; P < 0.001 vs control), and 31.3% ± 2.2% (32 hours; P < 0.001 vs control). There were a significant lower number of perfused acini in dependence on increasing cold storage time. The acinar perfusion index reached 0.970 ± 0.006 after 2 hours of cold ischemia (comparable to 0.960 ± 0.009 for sham livers) and declined continuously after 16, 24, and 32 hours cold ischemia (0.58 ± 0.03, 0.49 ± 0.02, 0.41 ± 0.03, each P < 0.0001 vs controls). Comparable results were found for sinusoidal perfusion, reaching 1.8% ± 0.4% of nonperfused sinusoids for 2 hours of cold ischemia and 8.2% ± 0.8% after 16 hours, 18.8% ± 1.4% after 24 hours, and 39.0% ± 2.4% after 32 hours (each P < 0.0001 vs controls). Prolonged cold ischemia was associated with an increasing number of TdT-mediated dUTP-biotin nick end labeling-positive cells (hepatocytes and sinusoidal lining cells), reaching 0.4 ± 0.1 (sham), 0.7 ± 0.4 (2 hours), 6.4 ± 1.1 (16 hours), 2.1 ± 0.3 (24 hours), and 14.7 ± 3.5 (32 hours; P = 0.002) for hepatocytes. CONCLUSIONS X-ray PCI of histological liver specimens can detect IR-induced tissue necrosis and can provide detailed complementary 3-dimensional information to standard histopathologic findings.
Collapse
|
8
|
Zheng L, Ding X, Liu K, Feng S, Tang B, Li Q, Huang D, Yang S. Molecular imaging of fibrosis using a novel collagen-binding peptide labelled with 99mTc on SPECT/CT. Amino Acids 2016; 49:89-101. [PMID: 27633720 DOI: 10.1007/s00726-016-2328-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Accepted: 09/07/2016] [Indexed: 12/18/2022]
Abstract
Fibrosis, closely related to chronic various diseases, is a pathological process characterised by the accumulation of collagen (largely collagen type I). Non-invasive methods are necessary for the diagnosis and follow-up of fibrosis. This study aimed to develop a collagen-targeted probe for the molecular imaging of fibrosis. We identified CPKESCNLFVLKD (CBP1495) as an original collagen-binding peptide using isothermal titration calorimetry and enzyme-linked immunosorbent assay. CBP1495 effectively bound to collagen type I (K d = 861 nM) and (GPO)9 (K d = 633 nM), a collagen mimetic peptide. Western blot and histochemistry validated CBP1495 targeting collagen in vitro and ex vivo. (Gly-(D)-Ala-Gly-Gly) was introduced to CBP1495 for coupling 99mTc. Labelling efficiency of 99mTc-CBP1495 was 95.06 ± 1.08 %. The physico-chemical properties, tracer kinetics and biodistribution of 99mTc-CBP1495 were carried out, and showed that the peptide stably chelated 99mTc in vitro and in vivo. SPECT/CT imaging with 99mTc-CBP1495 was performed in rat fibrosis models, and revealed that 99mTc-CBP1495 significantly accumulated in fibrotic lungs or livers of rats. Finally, 99mTc-CBP1495 uptake and hydroxyproline (Hyp), a specific amino acid of collagen, were quantitatively analysed. The results demonstrated that 99mTc-CBP1495 uptake was positvely correlated with Hyp content in lungs (P < 0.0001, r 2 = 0.8266) or livers (P < 0.0001, r 2 = 0.7581). Therefore, CBP1495 is a novel collagen-binding peptide, and 99mTc-labelled CBP1495 may be a promising radiotracer for the molecular imaging of fibrosis.
Collapse
Affiliation(s)
- Lei Zheng
- Department of Gastroenterology, Xinqiao Hospital, Third Military Medical University, Chongqing, 400037, China.,Department of Nuclear Medicine, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China
| | - Xiaojiang Ding
- Department of Nuclear Medicine, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China
| | - Kaiyun Liu
- National Engineering Research Center of Immunological Products, Department of Microbiology and Biochemical Pharmacy, College of Pharmacy, Third Military Medical University, Chongqing, 400038, China
| | - Shibin Feng
- Department of Cardiology, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China
| | - Bo Tang
- Department of Gastroenterology, Xinqiao Hospital, Third Military Medical University, Chongqing, 400037, China
| | - Qianwei Li
- Department of Nuclear Medicine, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China
| | - Dingde Huang
- Department of Nuclear Medicine, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China.
| | - Shiming Yang
- Department of Gastroenterology, Xinqiao Hospital, Third Military Medical University, Chongqing, 400037, China.
| |
Collapse
|
9
|
Assessment of fibrotic tissue and microvascular architecture by in-line phase-contrast imaging in a mouse model of liver fibrosis. Eur Radiol 2016; 26:2947-55. [PMID: 26787604 DOI: 10.1007/s00330-015-4173-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 09/25/2015] [Accepted: 12/14/2015] [Indexed: 12/18/2022]
Abstract
PURPOSE To explore the value of in-line phase-contrast imaging with computed tomography (ILPCI-CT) by synchrotron radiation (SR) for liver fibrosis. MATERIALS AND METHODS Liver fibrosis models were set up in 13 BALB/c mice by peritoneal injections of thioacetamide and evaluated by ILPCI-CT. Histological staging was used to categorize liver fibrosis into normal, mild fibrosis and advanced fibrosis groups. Microvessel density (MVD), the ratio of total vessel length to volume (L/V), the ratio of total number of branching points to liver volume (P/V) and the distribution of vessel diameter were assessed. RESULTS The CT images showed slightly high-density shadows around the portal tracts in the fibrosis group. Three-dimensional reconstruction can detect vascular and nodular changes on the surface of fibrotic livers. The MVDs between the three groups were significantly different (P = 0.024). L/V was significantly different between the three groups (P = 0.014). There was a positive correlation between MVD and P/V. CONCLUSION Fibrous material can be detected by ILPCI-CT even in the early stage of fibrosis. MVD, L/V, P/V and the distribution of vessel diameter were consistent with fibrosis-related angiogenesis progress. Three-dimensional reconstruction is a promising method to visualize morphological changes of the fibrotic liver. KEY POINTS • ILPCI-CT can detect fibrous material even in the early stage of liver fibrosis. • MVD, L/V, P/V, and the distribution of vascular diameter reflect pathological angiogenesis. • 3D reconstruction could be a promising approach for detecting liver fibrosis.
Collapse
|
10
|
Molecular evaluation of thrombosis using X-ray phase contrast imaging with microbubbles targeted to P-selectin in mice. Eur Radiol 2015; 26:3253-61. [PMID: 26628067 DOI: 10.1007/s00330-015-4129-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2015] [Revised: 11/15/2015] [Accepted: 11/19/2015] [Indexed: 10/22/2022]
Abstract
OBJECTIVES X-ray phase contrast imaging (PCI) provides excellent image contrast by utilizing the phase shift. The introduction of microbubbles into tissues can cause a phase shift to make microbubbles visibly identified on PCI. In this study, we assessed the feasibility of targeted microbubble-based PCI for the detection of thrombosis. METHODS The absorption and phase contrast images of P-selectin-targeted microbubbles (MBP) were obtained and compared in vitro. MBP, control IgG-targeted microbubbles (MBC), and unbound microbubbles (MBU) were tested for binding specificity on thrombi expressing P-selectin. MBP were used as molecular PCI probes to evaluate P-selectin expression in a mouse model of arteriovenous shunt thrombosis that was created using PE tubes in the bypass outside of the mouse body. RESULTS PCI clearly showed the microbubbles not viewable via absorption contrast imaging (ACI). In vitro attachment of MBP (91.60 ± 11.63) to thrombi was significantly higher than attachment of MBC (17.80 ± 4.02, P < 0.001) or MBU (9.80 ± 2.59, P < 0.001). In the mouse model of arteriovenous shunt thrombosis, the binding affinity of MBP (15.50 ± 6.25) was significantly greater than that of MBC (0.50 ± 0.84, P < 0.001) or MBU (0.33 ± 0.52, P < 0.001). CONCLUSIONS Our results indicate that molecular PCI may be considered as a novel and promising imaging modality for the investigation of thrombosis. KEY POINTS • Small thrombi are rarely detected by conventional radiography. • Phase contrast imaging (PCI) provides higher contrast and spatial resolution than conventional radiography. • P-selectin targeted microbubbles detected by PCI may suggest early thrombosis.
Collapse
|
11
|
Xuan R, Zhao X, Hu D, Jian J, Wang T, Hu C. Three-dimensional visualization of the microvasculature of bile duct ligation-induced liver fibrosis in rats by x-ray phase-contrast imaging computed tomography. Sci Rep 2015. [PMID: 26212186 PMCID: PMC4515745 DOI: 10.1038/srep11500] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
X-ray phase-contrast imaging (PCI) can substantially enhance contrast, and is particularly useful in differentiating biological soft tissues with small density differences. Combined with computed tomography (CT), PCI-CT enables the acquisition of accurate microstructures inside biological samples. In this study, liver microvasculature was visualized without contrast agents in vitro with PCI-CT using liver fibrosis samples induced by bile duct ligation (BDL) in rats. The histological section examination confirmed the correspondence of CT images with the microvascular morphology of the samples. By means of the PCI-CT and three-dimensional (3D) visualization technique, 3D microvascular structures in samples from different stages of liver fibrosis were clearly revealed. Different types of blood vessels, including portal veins and hepatic veins, in addition to ductular proliferation and bile ducts, could be distinguished with good sensitivity, excellent specificity and excellent accuracy. The study showed that PCI-CT could assess the morphological changes in liver microvasculature that result from fibrosis and allow characterization of the anatomical and pathological features of the microvasculature. With further development of PCI-CT technique, it may become a novel noninvasive imaging technique for the auxiliary analysis of liver fibrosis.
Collapse
Affiliation(s)
- Ruijiao Xuan
- College of Biomedical Engineering, Tianjin Medical University, Tianjin 300070, China
| | - Xinyan Zhao
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Doudou Hu
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Jianbo Jian
- College of Biomedical Engineering, Tianjin Medical University, Tianjin 300070, China
| | - Tailing Wang
- Department of Pathology, China-Japan Friendship Hospital, Beijing 100029, China
| | - Chunhong Hu
- College of Biomedical Engineering, Tianjin Medical University, Tianjin 300070, China
| |
Collapse
|
12
|
Fingerle AA, Willner M, Herzen J, Münzel D, Hahn D, Rummeny EJ, Noël PB, Pfeiffer F. Simulated Cystic Renal Lesions: Quantitative X-ray Phase-Contrast CT—An in Vitro Phantom Study. Radiology 2014; 272:739-48. [DOI: 10.1148/radiol.14130876] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
|
14
|
Tang R, Huang W, Yan F, Lu Y, Chai WM, Yang GY, Chen KM. In-line phase contrast imaging of hepatic portal vein embolization with radiolucent embolic agents in mice: a preliminary study. PLoS One 2013; 8:e80919. [PMID: 24324646 PMCID: PMC3851775 DOI: 10.1371/journal.pone.0080919] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2013] [Accepted: 10/18/2013] [Indexed: 01/22/2023] Open
Abstract
It is crucial to understand the distribution of embolic agents inside target liver during and after the hepatic portal vein embolization (PVE) procedure. For a long time, the problem has not been well solved due to the radiolucency of embolic agents and the resolution limitation of conventional radiography. In this study, we first reported use of fluorescent carboxyl microspheres (FCM) as radiolucent embolic agents for embolizing hepatic portal veins. The fluorescent characteristic of FCM could help to determine their approximate location easily. Additionally, the microspheres were found to be fairly good embolizing agents for PVE. After the livers were excised and fixed, they were imaged by in-line phase contrast imaging (PCI), which greatly improved the detection of the radiolucent embolic agents as compared to absorption contrast imaging (ACI). The preliminary study has for the first time shown that PCI has great potential in the pre-clinical investigation of PVE with radiolucent embolic agents.
Collapse
Affiliation(s)
- Rongbiao Tang
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
- * E-mail: (RT); (KMC)
| | - Wei Huang
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Fuhua Yan
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Yong Lu
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Wei-Min Chai
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Guo-Yuan Yang
- Neuroscience and Neuroengineering Center, Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
| | - Ke-Min Chen
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
- * E-mail: (RT); (KMC)
| |
Collapse
|
15
|
Microcomputed tomography with diffraction-enhanced imaging for morphologic characterization and quantitative evaluation of microvessel of hepatic fibrosis in rats. PLoS One 2013; 8:e78176. [PMID: 24205147 PMCID: PMC3804625 DOI: 10.1371/journal.pone.0078176] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Accepted: 09/09/2013] [Indexed: 12/12/2022] Open
Abstract
Backgroud Hepatic fibrosis can lead to deformation of vessel morphology and structure. In the present feasibility study, high-resolution computed tomography (CT) using diffraction-enhanced imaging (DEI) was used to represent three-dimensional (3D) vessel microstructures of hepatic fibrosis in rats and to differentiate different stages of hepatic fibrosis using qualitative descriptions and quantitative measurement of microvessels. Material and Methods Three typical specimens at different stages, i.e., mild, moderate and severe hepatic fibrosis, were imaged using DEI at 15 keV without contrast agents. The correspondence between DEI-CT images and histopathological findings was determined. The 3D visualizations from different stages of hepatic fibrosis were presented using DEI-CT. Additionally, Qualitative descriptions and quantitative evaluation of vessel features, such as vessel trend, vascular distortion deformation, thrombus formation and texture features on the inner wall of the vessel, were performed. Results DEI-CT produced high-resolution images of the vessel microstructures in hepatic fibrosis that corresponded to information on actual structures observed from the histological sections. Combined with the 3D visualization technique, DEI-CT enabled the acquisition of an accurate description of the 3D vessel morphology from different stages of hepatic fibrosis. Qualitative descriptions and quantitative assessment of microvessels demonstrated clear differences between the different stages of hepatic fibrosis. The thrombus inside the vessel of severe liver fibrosis was accurately displayed, and corresponding analysis can provide an exact measurement of vessel stenosis rate. Conclusions DEI-CT may allow morphologic descriptions and quantitative evaluation of vessel microstructures from different stages of hepatic fibrosis and can better characterize the various stages of fibrosis progression using high-resolution 3D vessel morphology.
Collapse
|