1
|
Pourvaziri A, Mroueh N, Cochran RL, Srinivas Rao S, Kambadakone A. Beyond Conventional CT: Role of Dual-Energy CT in Monitoring Response to Therapy in Abdominal Malignancies. Radiol Imaging Cancer 2025; 7:e240142. [PMID: 40249270 DOI: 10.1148/rycan.240142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2025]
Abstract
In the era of precision medicine, imaging plays a critical role in evaluating treatment response to various oncologic therapies. For decades, conventional morphologic assessments using cross-sectional imaging have been the standard for monitoring the effectiveness of systemic and locoregional therapies in patients with cancer. However, the development of new functional imaging tools has widened the scope of imaging from mere response assessment to patient selection and outcome prediction. Dual-energy CT (DECT), known for its superior material differentiation capabilities, shows promise in enhancing treatment response evaluation. DECT-based iodine quantification methods are increasingly being investigated as surrogates for assessing tumor vascularity and physiology, which is particularly important in patients undergoing emerging targeted therapies. The purpose of this review article is to discuss the current and emerging role of DECT in assessing treatment response in patients with malignant abdominal tumors. Keywords: CT-Dual Energy, Transcatheter Tumor Therapy, Tumor Response, Iodine Uptake, Therapeutic Response © RSNA, 2025.
Collapse
Affiliation(s)
- Ali Pourvaziri
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Nayla Mroueh
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Rory L Cochran
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Shravya Srinivas Rao
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| |
Collapse
|
2
|
Liu Q, Lu X, Lin Q, Zhu N, Xu Y. Correlation between perfusion and dual-layer spectral-detector CT in patients with cerebrovascular disorders. Eur Radiol 2025:10.1007/s00330-025-11641-x. [PMID: 40301168 DOI: 10.1007/s00330-025-11641-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2024] [Revised: 02/28/2025] [Accepted: 04/05/2025] [Indexed: 05/01/2025]
Abstract
OBJECTIVES To evaluate the correlation of cerebral perfusion parameters and iodine density (ID) map between conventional CT perfusion (CTP) and dual-layer spectral-detector CT (DLCT) in patients with cerebrovascular diseases. MATERIALS AND METHODS This study enrolled 163 patients with cerebrovascular disorders who received CTP and CT angiography examination by DLCT. Conventional CTP (cCTP), spectral virtual monochromatic images (VMIs) CTP (sCTP, from 40 keV to 70 keV in 10 keV increments, and 100 keV), and ID maps were reconstructed. CTP parameters included cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to peak (TTP) were generated from cCTP and sCTP. The differences and consistency between the cCTP and sCTP parameters were compared by the Kruskal-Wallis Test and Bland-Altman plots. The correlations between the ID maps and the cCTP or sCTP parameters were analyzed by the Spearman test. RESULTS Significant differences were observed in both sides of CBV, MTT, TTP, and left-sided CBF between cCTP and sCTP (p < 0.05). Bland-Altman plots demonstrated that the absolute values of CBF, CBV, MTT from 60 keV VMIs and nearly all relative sCTP values had good consistency with cCTP (p ≥ 0.05). Correlation analysis revealed that relative ID exhibited good correlation with relative CBF from cCTP (r = 0.673, p < 0.001), 50 keV (r = 0.604, p < 0.001), 60 keV (r = 0.628, p < 0.001), and 70 keV (r = 0.614, p < 0.001) VMIs. CONCLUSIONS Cerebral perfusion parameters from sCTP show good consistency with those from cCTP. Additionally, the relative ID maps demonstrate good correlations with the relative CBF. KEY POINTS Question Conventional brain CT perfusion is limited by high radiation dose, while quantitative dual-layer spectral-detector CT has been investigated as a low-dose alternative to perfusion measurement. Findings Dual-layer spectral detector CT-derived perfusion parameters showed good consistency with conventional brain CT perfusion, with the highest correlation with relative iodine density. Clinical relevance This study shows that dual-layer detector spectral CT-derived perfusion parameters, especially iodine density, have potential value to evaluate cerebral hemodynamics with less radiation dose and rapid imaging speed compared with conventional cerebral CTP.
Collapse
Affiliation(s)
- Qin Liu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China
| | - Xiaodan Lu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China
| | - Qihuan Lin
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China
| | - Na Zhu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China
| | - Yikai Xu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China.
| |
Collapse
|
3
|
Marchetti A, Mollica V, Brocchi S, Cattabrigra A, Tassinari E, Rosellini M, Massari F. Dual-energy spectral CT in renal cell carcinoma: dawn of a brand-new era? Expert Rev Mol Diagn 2025; 25:91-93. [PMID: 39949118 DOI: 10.1080/14737159.2025.2467962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Accepted: 02/12/2025] [Indexed: 02/19/2025]
Affiliation(s)
- Andrea Marchetti
- Medical Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Veronica Mollica
- Medical Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Stefano Brocchi
- Division of Interventional Radiology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Arrigo Cattabrigra
- Division of Interventional Radiology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Elisa Tassinari
- Medical Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Matteo Rosellini
- Medical Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Francesco Massari
- Medical Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| |
Collapse
|
4
|
García-Figueiras R, Baleato-González S. Quantitative multi-energy CT in oncology: State of the art and future directions. Eur J Radiol 2025; 182:111840. [PMID: 39581021 DOI: 10.1016/j.ejrad.2024.111840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2024] [Revised: 11/03/2024] [Accepted: 11/17/2024] [Indexed: 11/26/2024]
Abstract
Multi-energy computed tomography (CT) involves acquisition of two or more CT measurements with distinct energy spectra. Using the differential attenuation of tissues and materials at different X-ray energies, multi-energy CT allows distinction of tissues and materials. Multi-energy technology encompasses different types of CT systems, such as dual-energy CT and photon-counting CT, that can use information from the energy and type of material present in acquired images to create multiple datasets. These scanners have overcome many of the limitations of conventional CT, making it possible to improve the diagnostic performance of CT and expand its use to new applications through better tissue characterization and multiple quantitative parameters. Quantitative imaging biomarkers based on multi-energy CT have enormous potential in oncologic imaging, from the diagnosis and characterization of tumor phenotypes to the evaluation of the response to treatment. Nevertheless, implementing these techniques in clinical practice remains challenging. This article reviews the basic principles underlying multi-energy CT and the most recent technical developments in these systems together with their advantages and limitations to establish the value of quantitative imaging derived from multi-energy CT in the field of oncology.
Collapse
Affiliation(s)
- Roberto García-Figueiras
- Department of Radiology, Oncologic Imaging, Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706, Santiago de Compostela, Spain.
| | - Sandra Baleato-González
- Department of Radiology, Oncologic Imaging, Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706, Santiago de Compostela, Spain
| |
Collapse
|
5
|
Shrestha B, Stern NB, Zhou A, Dunn A, Porter T. Current trends in the characterization and monitoring of vascular response to cancer therapy. Cancer Imaging 2024; 24:143. [PMID: 39438891 PMCID: PMC11515715 DOI: 10.1186/s40644-024-00767-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 08/26/2024] [Indexed: 10/25/2024] Open
Abstract
Tumor vascular physiology is an important determinant of disease progression as well as the therapeutic outcome of cancer treatment. Angiogenesis or the lack of it provides crucial information about the tumor's blood supply and therefore can be used as an index for cancer growth and progression. While standalone anti-angiogenic therapy demonstrated limited therapeutic benefits, its combination with chemotherapeutic agents improved the overall survival of cancer patients. This could be attributed to the effect of vascular normalization, a dynamic process that temporarily reverts abnormal vasculature to the normal phenotype maximizing the delivery and intratumor distribution of chemotherapeutic agents. Longitudinal monitoring of vascular changes following antiangiogenic therapy can indicate an optimal window for drug administration and estimate the potential outcome of treatment. This review primarily focuses on the status of various imaging modalities used for the longitudinal characterization of vascular changes before and after anti-angiogenic therapies and their clinical prospects.
Collapse
Affiliation(s)
- Binita Shrestha
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA.
| | - Noah B Stern
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Annie Zhou
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Andrew Dunn
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Tyrone Porter
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA
| |
Collapse
|
6
|
Gu Y, Shi D, Shen H, Wang Y, Xu D, Xiao A, Jin D, Lu K, Cai W, Xu L. Nomogram Based on Dual-Layer Spectral Detector CTA Parameter for the Prediction of Infarct Core in Patients with Acute Ischemic Stroke. Diagnostics (Basel) 2023; 13:3434. [PMID: 37998572 PMCID: PMC10670594 DOI: 10.3390/diagnostics13223434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/30/2023] [Accepted: 11/09/2023] [Indexed: 11/25/2023] Open
Abstract
(1) Background: Acute ischemic stroke (AIS) is time-sensitive. The accurate identification of the infarct core and penumbra areas in AIS patients is an important basis for formulating treatment plans, and is the key to dual-layer spectral detector computed tomography angiography (DLCTA), a safer and more accurate diagnostic method for AIS that will replace computed tomography perfusion (CTP) in the future. Thus, this study aimed to investigate the value of DLCTA in differentiating infarct core from penumbra in patients with AIS to establish a nomogram combined with spectral computed tomography (CT) parameters for predicting the infarct core and performing multi-angle evaluation. (2) Methods: Data for 102 patients with AIS were retrospectively collected. All patients underwent DLCTA and CTP. The patients were divided into the non-infarct core group and the infarct core group, using CTP as the reference. Multivariate logistic regression analysis was used to screen predictors related to the infarct core and establish a nomogram model. The receiver operating characteristic (ROC) curve, the calibration curve, and decision curve analysis (DCA) were used to evaluate the predictive efficacy, accuracy, and clinical practicability of the model, respectively. (3) Results: Multivariate logistic analysis identified three independent predictors: iodine density (OR: 0.022, 95% CI: 0.003-0.170, p < 0.001), hypertension (OR: 7.179, 95% CI: 1.766-29.186, p = 0.006), and triglycerides (OR: 0.255, 95% CI: 0.109-0.594, p = 0.002). The AUC-ROC of the nomogram was 0.913. Calibration was good. Decision curve analysis was clinically useful. (4) Conclusions: The spectral CT parameters, specifically iodine density values, effectively differentiate between the infarct core and penumbra areas in patients with AIS. The nomogram, based on iodine density values, showed strong predictive power, discrimination, and clinical utility to accurately predict infarct core in AIS patients.
Collapse
Affiliation(s)
- Yan Gu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Dai Shi
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Hao Shen
- Department of Medical Oncology, Anhui Provincial Hospital Affiliated to Anhui Medical University, Hefei 230000, China;
| | - Yeqing Wang
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Dandan Xu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Aoqi Xiao
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Dan Jin
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Kuan Lu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Wu Cai
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| | - Liang Xu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou 215000, China; (Y.G.); (D.S.); (Y.W.); (D.X.); (A.X.); (D.J.); (K.L.); (W.C.)
| |
Collapse
|
7
|
Du M, Wang X, Zhuang S, Lou K, Li G, Xie X, Wang M, Zang H, Wang M, Shen W. Quantitative parameters in novel spectral computed tomography for assessing gastric cancer and cell proliferation. Eur J Radiol 2023; 167:111052. [PMID: 37643557 DOI: 10.1016/j.ejrad.2023.111052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 08/09/2023] [Accepted: 08/14/2023] [Indexed: 08/31/2023]
Abstract
OBJECTIVES To investigate the diagnostic ability of novel spectral CT-derived parameters for gastric cancer histological types and Ki-67 expression. METHODS A total of 72 patients with histologically proven gastric cancer (GC) were retrospectively included in this study. All patients underwent dual-phase enhanced abdominal spectral CT. The arterial (AP) and venous phase (VP) slope of the spectral curve (λHU), iodine concentration (IC), normalized IC (NIC), effective atomic number (Zeff) and iodine-no-water concentration were retrospectively compared between patients with low and high Ki-67 expression levels and with different histological types in GC patients. The ROI was outlined independently by two senior physicians, and the average of three measurements at the largest level was taken. In addition, interobserver reproducibility was assessed by Bland-Altman analysis. Correlations between quantitative parameters and Ki-67 expression levels were assessed by Spearman's correlation coefficients. RESULTS The values between the mucinous group and nonmucinous carcinoma group were significantly different in both phases. The IC, NIC, and iodine-no-water concentration in the VP were significantly different among the Ki-67_L, Ki-67_M, and Ki-67_H groups. Spearman rank correlation analysis demonstrated a positive correlation between Ki-67 expression levels and IC, NIC, and iodine-no-water concentration in the VP, with correlation coefficients of 0.304, 0.424, and 0.322, respectively. CONCLUSION Quantitative spectral parameters can discriminate between low and high Ki-67 expression and different histological types in GC. The NIC, IC and iodine-no-water concentration can be useful parameters for evaluating of Ki-67 expression levels.
Collapse
Affiliation(s)
- Mei Du
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Xiao Wang
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Shuhao Zhuang
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Kexin Lou
- Department of Pathology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Gang Li
- Department of General Surgery, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Xiaodong Xie
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Mengru Wang
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Hui Zang
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China
| | - Meiqin Wang
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China.
| | - Wenrong Shen
- Department of Radiology, The Affiliated Cancer Hospital of Nanjing Medical University & Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, Nanjing, China.
| |
Collapse
|
8
|
Zhu C, Hu J, Rong C, Zhou J, Zhang B, Gao Y, Li C, Li J, Wu X. Mucosal healing assessment in Crohn's disease with normalized iodine concentration from dual-energy CT enterography: comparison with endoscopy. Insights Imaging 2023; 14:63. [PMID: 37052746 PMCID: PMC10102270 DOI: 10.1186/s13244-023-01397-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 03/06/2023] [Indexed: 04/14/2023] Open
Abstract
OBJECTIVES Mucosal healing (MH) is an important goal in the treatment of patients with Crohn's disease (CD). Noninvasive assessment of MH with normalized iodine concentration (NIC) is unknown. METHODS In this retrospective study, 94 patients with diagnosed CD underwent endoscopy and dual-energy CT enterography (DECTE) at the post-infliximab treatment review. Two radiologists reviewed DECTE images by consensus for assessing diseased bowel segments of the colon or terminal ileum, and the NIC was measured. Patients were divided into transmural healing (TH), MH and non-MH groups. The diagnostic performance of the MH and non-MH groups with clinical factors and NIC was assessed utilizing receiver operating characteristic (ROC) curve analysis. RESULTS Of the 94 patients included in our study, 8 patients achieved TH, 34 patients achieved MH, and 52 patients did not achieve MH at the post-IFX treatment review. The area under the ROC curve (AUC), sensitivity, specificity, and accuracy values were 0.929 (95% confidence interval [CI] 0.883-0.967), 0.853, 0.827, and 0.837, respectively, for differentiating MHs from non-MHs, and the optimal NIC threshold was 0.448. The AUC of the combined model for distinguishing MHs from non-MHs in CD patients, which was based on the NIC and calprotectin, was 0.964 (95% CI 0.935-0.987). CONCLUSIONS The normalized iodine concentration measurement in DECTE has good performance in assessment MH in patients with CD. Iodine concentration from DECTE can be used as a radiologic marker for MH.
Collapse
Affiliation(s)
- Chao Zhu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China
| | - Jing Hu
- Department of Gastroenterology, The First Affiliated Hospital of Anhui Medical University, Hefei, People's Republic of China
| | - Chang Rong
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China
| | - Jianhua Zhou
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China
| | - Bo Zhang
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China
| | - Yankun Gao
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China
| | - Cuiping Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China
| | - Jianying Li
- CT Research Center, GE Healthcare China, Shanghai, People's Republic of China
| | - Xingwang Wu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, 230022, Anhui Province, People's Republic of China.
| |
Collapse
|
9
|
Skornitzke S, Mayer P, Kauczor HU, Stiller W. Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma: A potential alternative to the Patlak model of CT perfusion. Heliyon 2023; 9:e14726. [PMID: 37064458 PMCID: PMC10102198 DOI: 10.1016/j.heliyon.2023.e14726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 02/24/2023] [Accepted: 03/15/2023] [Indexed: 04/18/2023] Open
Abstract
Introduction By using bolus tracking with an appropriate acquisition delay dual-energy computed tomography (DECT) iodine maps might serve as a replacement of CT perfusion maps at reduced radiation exposure. This study aimed to evaluate the optimal acquisition delays of DECT for the replacement of parameter maps calculated with the Patlak model in pancreatic adenocarcinoma by corresponding iodine maps. Materials and methods Dual-source dynamic DECT acquisitions at 80 kVp/Sn140 kVp of 14 patients with pancreatic carcinoma were used to calculate CT perfusion maps of blood volume and permeability with the Patlak model. DECT iodine maps were generated from individual DECT acquisitions, matching acquisition times relative to prior bolus-triggered three-phase CT acquisitions for investigating different acquisition delays. Correlation between perfusion parameters and iodine concentrations was determined for acquisition delays between -6 s and 33 s. Results Correlation between iodine concentrations and perfusion parameters ranged from -0.05 to 0.63 for blood volume and from -0.05 to 0.71 for permeability, depending on potential trigger delay. The correlation was significant for potential acquisition delays above 1.5 s for blood volume and above 9.0 s for permeability (both p < 0.05). Maximum correlation occurred at an acquisition delay of 15.0 s for blood volume (r = 0.63) and at 25.5 s for permeability (r = 0.71), with significantly lower iodine concentrations in carcinoma (15.0 s: 1.3 ± 0.5 mg/ml; 22.5 s: 1.4 ± 0.7 mg/ml) than in non-neoplastic pancreatic parenchyma (15.0 s: 2.3 ± 0.8 mg/ml; 22.5 s: 2.4 ± 0.6 mg/ml; p < 0.05). Discussion In the future, well-timed DECT iodine maps acquired with bolus tracking could provide an alternative to permeability and blood volume maps calculated with the Patlak model.
Collapse
Affiliation(s)
| | | | | | - Wolfram Stiller
- Corresponding author. Diagnostic and Interventional Radiology (DIR) Heidelberg University Hospital Im Neuenheimer Feld 130.3 69120 Heidelberg, Germany
| |
Collapse
|
10
|
Mao LT, Chen WC, Lu JY, Zhang HL, Ye YS, Zhang Y, Liu B, Deng WW, Liu X. Quantitative parameters in novel spectral computed tomography: Assessment of Ki-67 expression in patients with gastric adenocarcinoma. World J Gastroenterol 2023; 29:1458-1469. [DOI: 10.3748/wjg.v29.i10.1458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/10/2023] Open
Abstract
BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer. The quantitative parameters based on the novel dual-layer spectral detector computed tomography (DLSDCT) in discriminating the Ki-67 expression status are unclear.
AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma (GC).
METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma. Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt (kev), the slope of the spectral curve (λHU), iodine concentration (IC), normalized IC (nIC), effective atomic number (Zeff) and normalized Zeff (nZeff) in the arterial phase (AP) and venous phase (VP) were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma. Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status. Receiver operating characteristic (ROC) curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.
RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression, respectively. CT40 kev-VP, CT70 kev-VP, CT100 kev-VP, and Zeff-related parameters were significantly higher, but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status, and other analyzed parameters showed no statistical difference between the two groups. Spearman’s correlation analysis showed that CT40 kev-VP, CT70 kev-VP, CT100 kev-VP, Zeff, and nZeff exhibited a negative correlation with Ki-67 status, whereas IC and nIC had positive correlation with Ki-67 status. The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status [area under the curve (AUC) = 0.967; sensitivity 95.77%; specificity 91.89%)]. Nevertheless, the differentiating capabilities of single-variable model were moderate (AUC value 0.630 - 0.835). In addition, the nZeffVP and nICVP (AUC 0.835 and 0.805) showed better performance than CT40 kev-VP, CT70 kev-VP and CT100 kev-VP (AUC 0.630, 0.631 and 0.662) in discriminating the Ki-67 status.
CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma. Zeff and IC may be useful parameters for evaluating the Ki-67 expression.
Collapse
Affiliation(s)
- Li-Ting Mao
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Wei-Cui Chen
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Jian-Ye Lu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Han-Liang Zhang
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Yong-Song Ye
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Yu Zhang
- Department of Pathology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Bo Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Wei-Wei Deng
- Department of Scientific Research, Clinical & Technical Support, Philips Healthcare China, Shanghai 200040, China
| | - Xian Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| |
Collapse
|
11
|
Mao LT, Chen WC, Lu JY, Zhang HL, Ye YS, Zhang Y, Liu B, Deng WW, Liu X. Quantitative parameters in novel spectral computed tomography: Assessment of Ki-67 expression in patients with gastric adenocarcinoma. World J Gastroenterol 2023; 29:1602-1613. [PMID: 36970586 PMCID: PMC10037253 DOI: 10.3748/wjg.v29.i10.1602] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 12/23/2022] [Accepted: 01/16/2023] [Indexed: 03/14/2023] Open
Abstract
BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer. The quantitative parameters based on the novel dual-layer spectral detector computed tomography (DLSDCT) in discriminating the Ki-67 expression status are unclear.
AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma (GC).
METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma. Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt (kev), the slope of the spectral curve (λHU), iodine concentration (IC), normalized IC (nIC), effective atomic number (Zeff) and normalized Zeff (nZeff) in the arterial phase (AP) and venous phase (VP) were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma. Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status. Receiver operating characteristic (ROC) curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.
RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression, respectively. CT40 kev-VP, CT70 kev-VP, CT100 kev-VP, and Zeff-related parameters were significantly higher, but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status, and other analyzed parameters showed no statistical difference between the two groups. Spearman’s correlation analysis showed that CT40 kev-VP, CT70 kev-VP, CT100 kev-VP, Zeff, and nZeff exhibited a negative correlation with Ki-67 status, whereas IC and nIC had positive correlation with Ki-67 status. The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status [area under the curve (AUC) = 0.967; sensitivity 95.77%; specificity 91.89%)]. Nevertheless, the differentiating capabilities of single-variable model were moderate (AUC value 0.630 - 0.835). In addition, the nZeffVP and nICVP (AUC 0.835 and 0.805) showed better performance than CT40 kev-VP, CT70 kev-VP and CT100 kev-VP (AUC 0.630, 0.631 and 0.662) in discriminating the Ki-67 status.
CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma. Zeff and IC may be useful parameters for evaluating the Ki-67 expression.
Collapse
Affiliation(s)
- Li-Ting Mao
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Wei-Cui Chen
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Jian-Ye Lu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Han-Liang Zhang
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Yong-Song Ye
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Yu Zhang
- Department of Pathology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Bo Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| | - Wei-Wei Deng
- Department of Scientific Research, Clinical & Technical Support, Philips Healthcare China, Shanghai 200040, China
| | - Xian Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
| |
Collapse
|
12
|
Haggenmüller B, Kreiser K, Sollmann N, Huber M, Vogele D, Schmidt SA, Beer M, Schmitz B, Ozpeynirci Y, Rosskopf J, Kloth C. Pictorial Review on Imaging Findings in Cerebral CTP in Patients with Acute Stroke and Its Mimics: A Primer for General Radiologists. Diagnostics (Basel) 2023; 13:diagnostics13030447. [PMID: 36766552 PMCID: PMC9914845 DOI: 10.3390/diagnostics13030447] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/19/2023] [Accepted: 01/21/2023] [Indexed: 01/28/2023] Open
Abstract
The imaging evaluation of computed tomography (CT), CT angiography (CTA), and CT perfusion (CTP) is of crucial importance in the setting of each emergency department for suspected cerebrovascular impairment. A fast and clear assignment of characteristic imaging findings of acute stroke and its differential diagnoses is essential for every radiologist. Different entities can mimic clinical signs of an acute stroke, thus the knowledge and fast identification of stroke mimics is important. A fast and clear assignment is necessary for a correct diagnosis and a rapid initiation of appropriate therapy. This pictorial review describes the most common imaging findings in CTP with clinical signs for acute stroke or other acute neurological disorders. The knowledge of these pictograms is therefore essential and should also be addressed in training and further education of radiologists.
Collapse
Affiliation(s)
- Benedikt Haggenmüller
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
- Correspondence:
| | - Kornelia Kreiser
- Department of Radiology and Neuroradiology, RKU—Universitäts- und Rehabilitationskliniken Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
| | - Nico Sollmann
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Magdalena Huber
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Daniel Vogele
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Stefan A. Schmidt
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Meinrad Beer
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Bernd Schmitz
- Department of Neuroradiology, Bezirkskrankenhaus Günzburg, Lindenallee 2, 89312 Günzburg, Germany
| | - Yigit Ozpeynirci
- Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Johannes Rosskopf
- Department of Neuroradiology, Bezirkskrankenhaus Günzburg, Lindenallee 2, 89312 Günzburg, Germany
| | - Christopher Kloth
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| |
Collapse
|
13
|
Drljevic-Nielsen A, Mains JR, Thorup K, Andersen MB, Rasmussen F, Donskov F. Early reduction in spectral dual-layer detector CT parameters as favorable imaging biomarkers in patients with metastatic renal cell carcinoma. Eur Radiol 2022; 32:7323-7334. [PMID: 35511260 DOI: 10.1007/s00330-022-08793-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/30/2022] [Accepted: 04/03/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES To associate the early change in DL-CT parameters and HU with survival outcomes and treatment response in patients with metastatic renal cell carcinoma (mRCC). METHODS DL-CT scans were performed at baseline and after 1 month of checkpoint immunotherapy or tyrosine kinase inhibitor therapy. Scans were reconstructed to conventional CT and DL-CT series, and used for assessment of HU, iodine concentration (IC), and the effective atomic number (Zeffective) in the combined RECISTv.1.1 target lesions. The relative changes, defined as ΔIC(combined), ΔZeffective(combined), and ΔHU(combined), were associated with progression-free survival (PFS), overall survival (OS), and objective response rate (ORR). The reduction in the sum of diameters of target lesions ≥ 30% after 1 month was associated with OS, PFS, and ORR. RESULTS Overall, 115 and 104 mRCC patients were included at baseline and 1 month, respectively. Median IC(combined) decreased from 2.3 to 1.2 mg/ml (p < 0.001), Zeffective(combined) from 8.5 to 8.0 (p < 0.001), and HU(combined) from 86.0 to 64.00 HU (p < 0.001). After multivariate adjustments, the largest reductions in ΔIC(combined) (HR 0.47, 95% CI: 0.24-0.94, p = 0.033) and ΔZeffective(combined) (HR = 0.43, 95% CI: 0.21-0.87, p = 0.019) were associated with favorable OS; the largest reduction in ΔZeffective(combined) was associated with higher response (OR = 2.79, 95% CI: 1.12-6.94, p = 0.027). The largest reduction in ΔHU(combined) was solely associated with OS in univariate analysis (HR 0.45, 95% CI: 0.23-0.91). Reduction in SOD ≥ 30% at 1 month was not associated with outcomes (p > 0.075). CONCLUSIONS Early reductions at 1 month in ΔIC(combined) and ΔZeffective(combined) are associated with favorable outcomes in patients with mRCC. This information may reassure physicians and patients about treatment strategy. KEY POINTS • Early reductions following 1 month of therapy in spectral dual-layer detector CT-derived iodine concentration and the effective atomic number (Zeffective) are independent biomarkers for better overall survival in patients with metastatic renal cell carcinoma. • Early reduction after 1 month of therapy in the effective atomic number (Zeffective) is an independent imaging biomarker for better treatment response metastatic renal cell carcinoma.
Collapse
Affiliation(s)
- Aska Drljevic-Nielsen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
- Department of Oncology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
| | - Jill R Mains
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark
| | - Kennet Thorup
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark
| | - Michael Brun Andersen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark
- Department of Radiology, Herlev/Gentofte, Denmark
| | - Finn Rasmussen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark
| | - Frede Donskov
- Department of Oncology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark
- Department of Oncology, University Hospital of Southern Denmark, Esbjerg, Denmark
| |
Collapse
|
14
|
Chen W, Ye Y, Zhang D, Mao L, Guo L, Zhang H, Du X, Deng W, Liu B, Liu X. Utility of dual-layer spectral-detector CT imaging for predicting pathological tumor stages and histologic grades of colorectal adenocarcinoma. Front Oncol 2022; 12:1002592. [PMID: 36248968 PMCID: PMC9564703 DOI: 10.3389/fonc.2022.1002592] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 09/09/2022] [Indexed: 11/13/2022] Open
Abstract
Objectives To assess the utility of Dual-layer spectral-detector CT (DLCT) in predicting the pT stage and histologic grade for colorectal adenocarcinoma (CRAC). Methods A total of 131 patients (mean 62.7 ± 12.9 years; 72 female, 59 male) with pathologically confirmed CRAC (35 pT1-2, 61 pT3, and 35 pT4; 32 high grade and 99 low grade), who received dual-phase DLCT were enrolled in this retrospective study. Normalized iodine concentration (NIC), slope of the spectral HU curve (λHU), and effective atomic number (Eff-Z) were measured for each lesion by two radiologists independently. Intraobserver reliability and interobserver agreement were assessed. The above values were compared between three pT-stage and two histologic-grade groups. The correlation between the pT stages and above values were assessed. Receiver operating characteristic (ROC) curves were calculated to evaluate the diagnostic efficacy. Results Intra-class correlation coefficients were ranged from 0.856 to 0.983 for all measurements. Eff-Z [7.21(0.09) vs 7.31 (0.10) vs 7.35 (0.19)], NICAP [0.11 (0.05) vs 0.15 (0.08) vs 0.15 (0.08)], NICVP [0.27 (0.06) vs 0.34 (0.11) vs 0.35 (0.12)], λHUAP [1.20 (0.45) vs 1.93 (1.18) vs 2.37 (0.91)], and λHUVP [2.07 (0.68) vs 2.35 (0.62) vs 3.09 (1.07)] were significantly different among pT stage groups (all P<0.001) and exhibited a positive correlation with pT stages (r= 0.503, 0.455, 0.394, 0.512, 0.376, respectively, all P<0.001). Eff-Z [7.37 (0.10) vs 7.28 (0.08)], NICAP[0.20 (0.10) vs 0.13 (0.08)], NICVP[0.35 (0.07) vs 0.31 (0.11)], and λHUAP [2.59 (1.11) vs 1.63 (0.75)] in the high-grade group were markedly higher than those in the low-grade group (all P<0.05). For discriminating the advanced- from early-stage CARC, the AUCs of Eff-Z, NICAP, NICVP, λHUAP, and λHUVP were 0.83, 0.80, 0.79, 0.86, and 0.68, respectively (all P<0.001). For discriminating the high- from low-grade CARC, the AUCs of Eff-Z, NICAP, NICVP, and λHUAP were 0.81, 0.81, 0.64, and 0.81, respectively (all P<0.05). Conclusions The quantitative parameters derived from DLCT may provide new markers for assessing pT stages and histologic differentiation in patients with CRAC.
Collapse
Affiliation(s)
- Weicui Chen
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Yongsong Ye
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Daochun Zhang
- Taizhou Hospital of Zhejiang Province affiliated to Wenzhou Medical University, Taizhou, China
| | - Liting Mao
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Lei Guo
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Hanliang Zhang
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiaohua Du
- Department of Pathology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Weiwei Deng
- Clinical and Technical Support, Philips Healthcare, Shanghai, China
| | - Bo Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xian Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
- *Correspondence: Xian Liu,
| |
Collapse
|
15
|
Lewin M, Laurent-Bellue A, Desterke C, Radu A, Feghali JA, Farah J, Agostini H, Nault JC, Vibert E, Guettier C. Evaluation of perfusion CT and dual-energy CT for predicting microvascular invasion of hepatocellular carcinoma. Abdom Radiol (NY) 2022; 47:2115-2127. [PMID: 35419748 DOI: 10.1007/s00261-022-03511-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 03/23/2022] [Accepted: 03/24/2022] [Indexed: 12/17/2022]
Abstract
PURPOSE Evaluation of perfusion CT and dual-energy CT (DECT) quantitative parameters for predicting microvascular invasion (MVI) of hepatocellular carcinoma (HCC) prior to surgery. METHODS This prospective single-center study included fifty-six patients (44 men; median age 67; range 31-84) who provided written informed consent. Inclusion criteria were (1) treatment-naïve patients with a diagnosis of HCC, (2) an indication for hepatic resection, and (3) available arterial DECT phase and perfusion CT (GE revolution HD-GSI). Iodine concentrations (IC), arterial density (AD), and 9 quantitative perfusion parameters for HCC were correlated to pathological results. Radiological parameters based principal component analysis (PCA), corroborated by unsupervised heatmap classification, was meant to deliver a model for predicting MVI in HCC. Survival analysis was performed using univariable log-rank test and multivariable Cox model, both censored at time of relapse. RESULTS 58 HCC lesions were analyzed (median size 42.3 mm; range of 20-140). PCA showed that the radiological model was predictive of tumor grade (p = 0.01), intratumoral MVI (p = 0.004), peritumoral MVI (p = 0.04), MTM (macrotrabecular-massive) subtype (p = 0.02), and capsular invasion (p = 0.02) in HCC. Heatmap classification of HCC showed tumor heterogeneity, stratified into three main clusters according to the risk of relapse. Survival analysis confirmed that permeability surface-area product (PS) was the only significant independent parameter, among all quantitative tumoral CT parameters, for predicting a risk of relapse (Cox p value = 0.004). CONCLUSION A perfusion CT and DECT-based quantitative imaging profile can provide a diagnosis of histological MVI in HCC. PS is an independent parameter for relapse. CLINICAL TRIALS ClinicalTrials.gov: NCT03754192.
Collapse
Affiliation(s)
- Maïté Lewin
- Service de Radiologie, AP-HP-Université Paris Saclay Hôpital Paul Brousse, 12-14 avenue Paul Vaillant Couturier, 94800, Villejuif, France.
- Faculté de Médecine, Université Paris Saclay, 94270, Le Kremlin-Bicêtre, France.
| | - Astrid Laurent-Bellue
- Faculté de Médecine, Université Paris Saclay, 94270, Le Kremlin-Bicêtre, France
- Service d'Anatomopathologie, AP-HP-Université Paris Saclay Hôpital Bicêtre, 94270, Le Kremlin-Bicêtre, France
| | - Christophe Desterke
- Faculté de Médecine, Université Paris Saclay, 94270, Le Kremlin-Bicêtre, France
- Service de Bio-informatique, INSERM UA9, Hôpital Paul Brousse, 94800, Villejuif, France
| | - Adina Radu
- Service de Radiologie, AP-HP-Université Paris Saclay Hôpital Paul Brousse, 12-14 avenue Paul Vaillant Couturier, 94800, Villejuif, France
| | - Joëlle Ann Feghali
- Service de Radiologie, AP-HP-Université Paris Saclay Hôpital Paul Brousse, 12-14 avenue Paul Vaillant Couturier, 94800, Villejuif, France
| | - Jad Farah
- Service de Radiologie, AP-HP-Université Paris Saclay Hôpital Paul Brousse, 12-14 avenue Paul Vaillant Couturier, 94800, Villejuif, France
| | - Hélène Agostini
- Service d'Epidémiologie et de Santé Publique, AP-HP-Université Paris Saclay Hôpital Bicêtre, 94270, Le Kremlin-Bicêtre, France
| | - Jean-Charles Nault
- Service d'Hépatologie, AP-HP, Hôpitaux Universitaires Paris-Seine-Saint-Denis, Hôpital Avicenne, 93000, Bobigny, France
- Functional Genomics of Solid Tumors Laboratory, Centre de Recherche Des Cordeliers, Sorbonne Université, Inserm, USPC, Université Paris Descartes, Université Paris Diderot, Université Paris 13, 75006, Paris, France
- Université Paris 13, Unité de Formation et de Recherche Santé Médecine et Biologie Humaine, 93000, Bobigny, France
| | - Eric Vibert
- Faculté de Médecine, Université Paris Saclay, 94270, Le Kremlin-Bicêtre, France
- AP-HP-Université Paris Saclay, Hôpital Paul Brousse, 94800, Villejuif, France
- Centre Hépato-Biliaire, INSERM U1193 Hôpital Paul Brousse, 94800, Villejuif, France
| | - Catherine Guettier
- Faculté de Médecine, Université Paris Saclay, 94270, Le Kremlin-Bicêtre, France
- Service d'Anatomopathologie, AP-HP-Université Paris Saclay Hôpital Bicêtre, 94270, Le Kremlin-Bicêtre, France
- Centre Hépato-Biliaire, INSERM U1193 Hôpital Paul Brousse, 94800, Villejuif, France
| |
Collapse
|
16
|
Zhang H, Zou Y, Tian F, Li W, Ji X, Guo Y, Li Q, Sun S, Sun F, Shen L, Xia S. Dual-energy CT may predict post-operative recurrence in early-stage glottic laryngeal cancer: a novel nomogram and risk stratification system. Eur Radiol 2022; 32:1921-1930. [PMID: 34762148 DOI: 10.1007/s00330-021-08265-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 06/13/2021] [Accepted: 06/30/2021] [Indexed: 02/07/2023]
Abstract
OBJECTIVES To establish and validate a predictive model integrating with clinical and dual-energy CT (DECT) variables for individual recurrence-free survival (RFS) prediction in early-stage glottic laryngeal cancer (EGLC) after larynx-preserving surgery. METHODS This retrospective study included 212 consecutive patients with EGLC who underwent DECT before larynx-preserving surgery between January 2015 and December 2018. Using Cox proportional hazard regression model to determine independent predictors for RFS and presented on a nomogram. The model's performance was assessed using Harrell's concordance index (C-index), time-dependent area under curve (TD-AUC) plot, and calibration curve. A risk stratification system was established using the nomogram with median scores of all cases to divide all patients into two prognostic groups. RESULTS Recurrence occurred in 39/212 (18.4%) cases. Normalized iodine concentration in arterial (NICAP) and venous phases (NICVP) were verified as significant predictors of RFS in multivariate Cox regression (hazard ratio [HR], 4.2; 95% confidence interval [CI]: 2.3, 7.7, p < .001 and HR, 3.0; 95% CI: 1.5, 5.9, p = .002, respectively). Nomogram based on clinical and DECT variables was better than did only clinical variables. The prediction model proved well-calibrated and had good discriminative ability in the training and validation samples. A risk stratification system was built that could effectively classify EGLC patients into two risk groups. CONCLUSIONS DECT could provide independent RFS indicators in patients with EGLC, and the nomogram based on DECT and clinical variables was useful in predicting RFS at several time points. KEY POINTS • Dual-energy CT(DECT) variables can predict recurrence-free survival (RFS) after larynx-preserving surgery in patients with early-stage glottic laryngeal cancer (EGLC). • The model that integrates clinical and DECT variables predicted RFS better than did only clinical variables. • A risk stratification system based on the nomogram could effectively classify EGLC patients into two risk groups.
Collapse
Affiliation(s)
- Huanlei Zhang
- Department of Radiology, First Central Clinical College, Tianjin Medical University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
- Department of Radiology, Yidu Central Hospital of Weifang, No. 4138 Linglongshan South Road, Qingzhou City, 262500, Shandong, China
| | - Ying Zou
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, No. 314 Anshan West Road, Nankai District, Tianjin, 300193, China
| | - Fengyue Tian
- Department of Radiology, Affiliated Hospital of Nankai University (Tianjin No. 4 Hospital), Tianjin, 300222, China
| | - Wenfei Li
- Department of Radiology, The First Hospital of Qinhuangdao, No. 258 Wenhua Road, Haigang District, Qinhuangdao, 066000, China
| | - Xiaodong Ji
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
| | - Yu Guo
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
| | - Qing Li
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
| | - Shuangyan Sun
- Department of Radiology, First Central Clinical College, Tianjin Medical University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
- Department of Radiology, Jilin Cancer Hospital, No. 1066 JinHu Road, Chaoyang District, , Changchun, 130000, China
| | - Fang Sun
- Department of Radiology, First Central Clinical College, Tianjin Medical University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
- Department of Ultrasonography, Binzhou Medical University Hospital, No. 661 Huanghe 2nd Road, Binzhou City, Shandong, 256603, China
| | - Lianfang Shen
- Department of Radiology, First Central Clinical College, Tianjin Medical University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China
- Department of Radiology, Yidu Central Hospital of Weifang, No. 4138 Linglongshan South Road, Qingzhou City, 262500, Shandong, China
| | - Shuang Xia
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, No. 24 Fu Kang Road, Nankai District, Tianjin, 300192, China.
| |
Collapse
|
17
|
Cao Y, Zhang J, Bao H, Zhang G, Yan X, Wang Z, Ren J, Chai Y, Zhao Z, Zhou J. Development of a Nomogram Combining Clinical Risk Factors and Dual-Energy Spectral CT Parameters for the Preoperative Prediction of Lymph Node Metastasis in Patients With Colorectal Cancer. Front Oncol 2021; 11:689176. [PMID: 34631524 PMCID: PMC8493878 DOI: 10.3389/fonc.2021.689176] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 09/02/2021] [Indexed: 11/13/2022] Open
Abstract
Objective This study aimed to develop a dual-energy spectral computed tomography (DESCT) nomogram that incorporated both clinical factors and DESCT parameters for individual preoperative prediction of lymph node metastasis (LNM) in patients with colorectal cancer (CRC). Material and Methods We retrospectively reviewed 167 pathologically confirmed patients with CRC who underwent enhanced DESCT preoperatively, and these patients were categorized into training (n = 117) and validation cohorts (n = 50). The monochromatic CT value, iodine concentration value (IC), and effective atomic number (Eff-Z) of the primary tumors were measured independently in the arterial phase (AP) and venous phase (VP) by two radiologists. DESCT parameters together with clinical factors were input into the prediction model for predicting LNM in patients with CRC. Logistic regression analyses were performed to screen for significant predictors of LNM, and these predictors were presented as an easy-to-use nomogram. The receiver operating characteristic curve and decision curve analysis (DCA) were used to evaluate the clinical usefulness of the nomogram. Results The logistic regression analysis showed that carcinoembryonic antigen, carbohydrate antigen 199, pericolorectal fat invasion, ICAP, ICVP, and Eff-ZVP were independent predictors in the predictive model. Based on these predictors, a quantitative nomogram was developed to predict individual LNM probability. The area under the curve (AUC) values of the nomogram were 0.876 in the training cohort and 0.852 in the validation cohort, respectively. DCA showed that our nomogram has outstanding clinical utility. Conclusions This study presents a clinical nomogram that incorporates clinical factors and DESCT parameters and can potentially be used as a clinical tool for individual preoperative prediction of LNM in patients with CRC.
Collapse
Affiliation(s)
- Yuntai Cao
- Department of Radiology, Affiliated Hospital of Qinghai University, Xining, China.,Second Clinical School, Lanzhou University, Lanzhou, China.,Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China
| | - Jing Zhang
- Department of Radiology, The Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China
| | - Haihua Bao
- Department of Radiology, Affiliated Hospital of Qinghai University, Xining, China
| | - Guojin Zhang
- Department of Radiology, Sichuan Provincial People's Hospital, Chengdu, China
| | - Xiaohong Yan
- Department of Critical Medicine, Affiliated Hospital of Qinghai University, Xining, China
| | - Zhan Wang
- Department of Hepatopancreatobiliary Surgery, Affiliated Hospital of Qinghai University, Xining, China
| | - Jialiang Ren
- Department of Pharmaceuticals Diagnosis, General Electrics (GE) Healthcare, Beijing, China
| | - Yanjun Chai
- Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China
| | - Zhiyong Zhao
- Second Clinical School, Lanzhou University, Lanzhou, China.,Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China
| | - Junlin Zhou
- Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China
| |
Collapse
|
18
|
Lennartz S, Parakh A, Cao J, Zopfs D, Große Hokamp N, Kambadakone A. Inter-scan and inter-scanner variation of quantitative dual-energy CT: evaluation with three different scanner types. Eur Radiol 2021; 31:4438-4451. [PMID: 33443600 DOI: 10.1007/s00330-020-07611-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/23/2020] [Accepted: 12/04/2020] [Indexed: 03/24/2023]
Abstract
OBJECTIVES To investigate inter-scan and inter-scanner variation of iodine concentration (IC) and attenuation in virtual monoenergetic images at 65 keV (HU65keV) in patients with repeated abdominal examinations on dual-source (dsDECT), rapid kV switching (rsDECT), and dual-layer detector DECT (dlDECT). METHODS We retrospectively included 131 patients who underwent two abdominal DECT examinations on the same scanner (dsDECT: n = 46, rsDECT: n = 45, dlDECT: n = 40). IC and HU65keV were measured by placing regions of interest in the liver, spleen, kidneys, aorta, portal vein, and inferior vena cava. Overall IC and HU65keV for each scanner, their inter-scan differences and proportional variation were calculated and compared between scanner types. RESULTS The three scanner-specific cohorts showed similar weight, body diameter, age, sex, and contrast media injection parameters as well as inter-scan differences hereof (p range: 0.23-0.99). Absolute inter-scan differences of HU65keV and IC were comparable between scanners (p range: 0.08-1.0). Overall inter-scan variation was significantly higher in IC than HU65keV (p < 0.05). For the liver, rsDECT showed significantly lower inter-scan variation of IC compared to dsDECT/dlDECT (p = 0.005/0.01), while for the spleen, this difference was only significant compared to dsDECT (p = 0.015). Normalizing IC of the liver to the portal vein and of the spleen to the aorta did not significantly reduce inter-scan variation (p = 0.97 and 0.50). CONCLUSIONS Iodine measurements across different DECT scanners show inter-scan variation which is higher compared to variation of attenuation values. Inter-scanner differences in longitudinal variation and overall iodine concentration depend on the scanner pairs and organs assessed and should be acknowledged in clinical and scientific DECT applications. KEY POINTS • All scanner types showed comparable inter-scan variation of attenuation, while for iodine, the rapid kV switching DECT showed lower variability in the liver and spleen. • Iodine concentration showed higher inter-scan variation than attenuation measurements; normalization to vessels did not significantly improve inter-scan reproducibility of iodine concentration in parenchymal organs. • Differences between the three scanner types regarding overall iodine concentration and attenuation obtained from both timepoints were within the range of average intra-patient, inter-scan differences for most assessed organs and vessels.
Collapse
Affiliation(s)
- Simon Lennartz
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Anushri Parakh
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
| | - Jinjin Cao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
| | - David Zopfs
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Nils Große Hokamp
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA.
| |
Collapse
|
19
|
Cao Y, Zhang G, Bao H, Ren J, Wang Z, Zhang J, Zhao Z, Yan X, Chai Y, Zhou J. Development of a dual-energy spectral computed tomography-based nomogram for the preoperative discrimination of histological grade in colorectal adenocarcinoma patients. J Gastrointest Oncol 2021; 12:544-555. [PMID: 34012648 DOI: 10.21037/jgo-20-368] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Background The usefulness of a dual-energy spectral computed tomography (DESCT)-based nomogram in discriminating between histological grades of colorectal adenocarcinoma (CRAC) is unclear. This study aimed to develop such a nomogram and assess its ability to preoperatively discriminate between histological grades in CRAC patients. Methods Primary tumors monochromatic CT value, iodine concentration (IC) value, and effective atomic number (Eff-Z) in the arterial (AP) and venous phases (VP) were retrospectively compared between patients with high-grade (n=65) and low-grade (n=108) CRAC who underwent preoperative abdominal DESCT. Univariate analysis was used to compare the DESCT parameters and clinical factors between these two patient groups. Statistically significant features in the univariate analysis were included in the multivariate logistic regression model to identify the indicators for building a nomogram that could discriminate between histological grades in CRAC patients. The clinical usefulness of the nomogram and its value for predicting overall survival were statistically evaluated. Results The logistic regression analysis showed that age, clinical T stage, clinical N stage, and IC values in AP and VP were significant independent predictors for high-grade CRAC. A quantitative nomogram developed based on these predictors showed excellent performance for discriminating between the histological grades, with an area under the curve (AUC) of 0.886 and excellent agreement in the calibration curve. The Kaplan-Meier curve for overall survival showed that our nomogram identified a significant difference between the high- and low-risk groups [hazard ratio (HR), 2.188; 95% CI, 1.072-4.465; P=0.027). Conclusions This study presents a nomogram that incorporates DESCT parameters and clinical factors and can potentially be used as a clinical tool for individual preoperative prediction of CRAC histological grade.
Collapse
Affiliation(s)
- Yuntai Cao
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China.,Department of Radiology, Affiliated Hospital of Qinghai University, Xining, China
| | - Guojin Zhang
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China
| | - Haihua Bao
- Department of Radiology, Affiliated Hospital of Qinghai University, Xining, China
| | - Jialiang Ren
- Department of Pharmaceuticals Diagnosis, GE Healthcare, Beijing, China
| | - Zhan Wang
- Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Jing Zhang
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China
| | - Zhiyong Zhao
- Second Clinical School, Lanzhou University, Lanzhou, China.,Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China
| | - Xiaohong Yan
- Department of Critical Medicine, Affiliated Hospital of Qinghai University, Xining, China
| | - Yanjun Chai
- Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China
| | - Junlin Zhou
- Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China.,Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China
| |
Collapse
|
20
|
Zopfs D, Reimer RP, Sonnabend K, Rinneburger M, Hentschke CM, Persigehl T, Lennartz S, Große Hokamp N. Intraindividual Consistency of Iodine Concentration in Dual-Energy Computed Tomography of the Chest and Abdomen. Invest Radiol 2021; 56:181-187. [PMID: 32932376 DOI: 10.1097/rli.0000000000000724] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVES Dual-energy computed tomography (DECT)-derived quantification of iodine concentration (IC) is increasingly used in oncologic imaging to characterize lesions and evaluate treatment response. However, only limited data are available on intraindividual consistency of IC and its variation. This study investigates the longitudinal reproducibility of IC in organs, vessels, and lymph nodes in a large cohort of healthy patients who underwent repetitive DECT imaging. MATERIALS AND METHODS A total of 159 patients, who underwent a total of 469 repetitive (range, 2-4), clinically indicated portal-venous phase DECT examinations of the chest and abdomen, were retrospectively included. At time of imaging, macroscopic tumor burden was excluded by follow-up imaging (≥3 months). Iodine concentration was measured region of interest-based (N = 43) in parenchymatous organs, vessels, lymph nodes, and connective tissue. Normalization of IC to the aorta and to the trigger delay as obtained from bolus tracking was performed. For statistical analysis, intraclass correlation coefficient and modified variation coefficient (MVC) were used to assess intraindividual agreement of IC and its variation between different time points, respectively. Furthermore, t tests and analysis of variance with Tukey-Kramer post hoc test were used. RESULTS The mean intraclass correlation coefficient over all regions of interest was good to excellent (0.642-0.936), irrespective of application of normalization or the normalization technique. Overall, MVC ranged from 1.8% to 25.4%, with significantly lower MVC in data normalized to the aorta (5.8% [1.8%-15.8%]) in comparison with the MVC of not normalized data and data normalized to the trigger delay (P < 0.01 and P = 0.04, respectively). CONCLUSIONS Our study confirms intraindividual, longitudinal variation of DECT-derived IC, which varies among vessels, lymph nodes, organs, and connective tissue, following different perfusion characteristics; normalizing to the aorta seems to improve reproducibility when using a constant contrast media injection protocol.
Collapse
Affiliation(s)
- David Zopfs
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | - Robert Peter Reimer
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | - Kristina Sonnabend
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | - Miriam Rinneburger
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | | | - Thorsten Persigehl
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | | | - Nils Große Hokamp
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| |
Collapse
|
21
|
Spectral CT in clinical routine imaging of neuroendocrine neoplasms. Clin Radiol 2021; 76:348-357. [PMID: 33610290 DOI: 10.1016/j.crad.2020.12.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 12/24/2020] [Indexed: 12/14/2022]
Abstract
AIM To evaluate the potential of new spectral computed tomography (SCT)-based tools in patients with neuroendocrine neoplasms (NEN). MATERIAL AND METHODS Eighty-eight consecutive patients with NENs were included prospectively. The patients underwent multiphase CT with spectral and standard mode. The signal-to-noise ratio (SNR)/contrast-to-noise-ratio (CNR)tumour-to-liver, iodine concentrations (ICs, total tumour/hotspot) and attenuation slopes in virtual monochromatic images (VMIs) were used to assess NEN-specific SCT values in primary tumours and metastatic lesions and investigate a possible lesion contrast improvement as well as possible correlations of SCT parameters to primary tumour location and tumour grade. Furthermore, the usability of SCT parameters to differentiate between the primary tumour and metastatic lesions, and to predict tumour response after 6-months follow-up was analyzed. The applied dose of spectral and standard mode was compared intra-individually. RESULTS SNR/CNRtumour-to-liver significantly increased in low-energy VMIs. NENs showed significant differences in ICs between primary and metastatic lesions for both absolute and normalised values (p<0.001) regardless of whether the total tumour or the hotspot was measured. There was also a significant difference in the attenuation slope (p<0.001). No significant correlations were found between SCT and tumour grade. A tumour response prediction by SCT parameters was not possible. The applied dose was comparable between the scan modes. CONCLUSION SCT was comparable regarding applied dose, improved tumour contrast, and contributed to differentiation between primary NEN and metastasis.
Collapse
|
22
|
Zopfs D, Graffe J, Reimer RP, Schäfer S, Persigehl T, Maintz D, Borggrefe J, Haneder S, Lennartz S, Große Hokamp N. Quantitative distribution of iodinated contrast media in body computed tomography: data from a large reference cohort. Eur Radiol 2020; 31:2340-2348. [PMID: 32997173 PMCID: PMC7979665 DOI: 10.1007/s00330-020-07298-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 07/27/2020] [Accepted: 09/15/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVES Dual-energy computed tomography allows for an accurate and reliable quantification of iodine. However, data on physiological distribution of iodine concentration (IC) is still sparse. This study aims to establish guidance for IC in abdominal organs and important anatomical landmarks using a large cohort of individuals without radiological tumor burden. METHODS Five hundred seventy-one oncologic, portal venous phase dual-layer spectral detector CT studies of the chest and abdomen without tumor burden at time point of imaging confirmed by > 3-month follow-up were included. ROI were placed in parenchymatous organs (n = 25), lymph nodes (n = 6), and vessels (n = 3) with a minimum of two measurements per landmark. ROI were placed on conventional images and pasted to iodine maps to retrieve absolute IC. Normalization to the abdominal aorta was conducted to obtain iodine perfusion ratios. Bivariate regression analysis, t tests, and ANOVA with Tukey-Kramer post hoc test were used for statistical analysis. RESULTS Absolute IC showed a broad scatter and varied with body mass index, between different age groups and between the sexes in parenchymatous organs, lymph nodes, and vessels (range 0.0 ± 0.0 mg/ml-6.6 ± 1.3 mg/ml). Unlike absolute IC, iodine perfusion ratios did not show dependency on body mass index; however, significant differences between the sexes and age groups persisted, showing a tendency towards decreased perfusion ratios in elderly patients (e.g., liver 18-44 years/≥ 64 years: 0.50 ± 0.11/0.43 ± 0.10, p ≤ 0.05). CONCLUSIONS Distribution of IC obtained from a large-scale cohort is provided. As significant differences between sexes and age groups were found, this should be taken into account when obtaining quantitative iodine concentrations and applying iodine thresholds. KEY POINTS • Absolute iodine concentration showed a broad variation and differed between body mass index, age groups, and between the sexes in parenchymatous organs, lymph nodes, and vessels. • The iodine perfusion ratios did not show dependency on body mass index while significant differences between sexes and age groups persisted. • Provided guidance values may serve as reference when aiming to differentiate healthy and abnormal tissue based on iodine perfusion ratios.
Collapse
Affiliation(s)
- David Zopfs
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - Josefine Graffe
- Faculty of Medicine, University of Cologne, Cologne, Germany
| | - Robert Peter Reimer
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | | | - Thorsten Persigehl
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - David Maintz
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - Jan Borggrefe
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - Stefan Haneder
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - Simon Lennartz
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany.,Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Nils Große Hokamp
- University Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany.
| |
Collapse
|
23
|
Beyer T, Bidaut L, Dickson J, Kachelriess M, Kiessling F, Leitgeb R, Ma J, Shiyam Sundar LK, Theek B, Mawlawi O. What scans we will read: imaging instrumentation trends in clinical oncology. Cancer Imaging 2020; 20:38. [PMID: 32517801 PMCID: PMC7285725 DOI: 10.1186/s40644-020-00312-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 04/17/2020] [Indexed: 12/16/2022] Open
Abstract
Oncological diseases account for a significant portion of the burden on public healthcare systems with associated costs driven primarily by complex and long-lasting therapies. Through the visualization of patient-specific morphology and functional-molecular pathways, cancerous tissue can be detected and characterized non-invasively, so as to provide referring oncologists with essential information to support therapy management decisions. Following the onset of stand-alone anatomical and functional imaging, we witness a push towards integrating molecular image information through various methods, including anato-metabolic imaging (e.g., PET/CT), advanced MRI, optical or ultrasound imaging.This perspective paper highlights a number of key technological and methodological advances in imaging instrumentation related to anatomical, functional, molecular medicine and hybrid imaging, that is understood as the hardware-based combination of complementary anatomical and molecular imaging. These include novel detector technologies for ionizing radiation used in CT and nuclear medicine imaging, and novel system developments in MRI and optical as well as opto-acoustic imaging. We will also highlight new data processing methods for improved non-invasive tissue characterization. Following a general introduction to the role of imaging in oncology patient management we introduce imaging methods with well-defined clinical applications and potential for clinical translation. For each modality, we report first on the status quo and, then point to perceived technological and methodological advances in a subsequent status go section. Considering the breadth and dynamics of these developments, this perspective ends with a critical reflection on where the authors, with the majority of them being imaging experts with a background in physics and engineering, believe imaging methods will be in a few years from now.Overall, methodological and technological medical imaging advances are geared towards increased image contrast, the derivation of reproducible quantitative parameters, an increase in volume sensitivity and a reduction in overall examination time. To ensure full translation to the clinic, this progress in technologies and instrumentation is complemented by advances in relevant acquisition and image-processing protocols and improved data analysis. To this end, we should accept diagnostic images as "data", and - through the wider adoption of advanced analysis, including machine learning approaches and a "big data" concept - move to the next stage of non-invasive tumour phenotyping. The scans we will be reading in 10 years from now will likely be composed of highly diverse multi-dimensional data from multiple sources, which mandate the use of advanced and interactive visualization and analysis platforms powered by Artificial Intelligence (AI) for real-time data handling by cross-specialty clinical experts with a domain knowledge that will need to go beyond that of plain imaging.
Collapse
Affiliation(s)
- Thomas Beyer
- QIMP Team, Centre for Medical Physics and Biomedical Engineering, Medical University Vienna, Währinger Gürtel 18-20/4L, 1090, Vienna, Austria.
| | - Luc Bidaut
- College of Science, University of Lincoln, Lincoln, UK
| | - John Dickson
- Institute of Nuclear Medicine, University College London Hospital, London, UK
| | - Marc Kachelriess
- Division of X-ray imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, DE, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074, Aachen, DE, Germany
- Fraunhofer Institute for Digital Medicine MEVIS, Am Fallturm 1, 28359, Bremen, DE, Germany
| | - Rainer Leitgeb
- Centre for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, AT, Austria
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Lalith Kumar Shiyam Sundar
- QIMP Team, Centre for Medical Physics and Biomedical Engineering, Medical University Vienna, Währinger Gürtel 18-20/4L, 1090, Vienna, Austria
| | - Benjamin Theek
- Institute for Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074, Aachen, DE, Germany
- Fraunhofer Institute for Digital Medicine MEVIS, Am Fallturm 1, 28359, Bremen, DE, Germany
| | - Osama Mawlawi
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
24
|
Iodine Parameters in Triple-Bolus Dual-Energy CT Correlate With Perfusion CT Biomarkers of Angiogenesis in Renal Cell Carcinoma. AJR Am J Roentgenol 2020; 214:808-816. [PMID: 32069083 DOI: 10.2214/ajr.19.21969] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE. The purpose of this study is to determine the degree of the relationship between perfusion CT (PCT) parameters and iodine concentration metrics derived from triple-bolus dual-energy CT (DECT) and to compare the radiation dose delivered. SUBJECTS AND METHODS. This single-center prospective study was conducted from October 2015 to September 2017. Twenty-three consenting adults (15 men and eight women; mean [± SD] age, 56 ± 13 years [range, 25-78 years]) with renal cell carcinomas underwent consecutive PCT and triple-bolus DECT examinations. Triple-bolus DECT consisted of synchronous corticomedullary, nephrographic, and delayed phase scans acquired using a dual-source DECT scanner. Two readers independently analyzed blood flow, blood volume, and permeability, as measured by PCT, and iodine density and iodine ratio, as measured by triple-bolus DECT. Size-specific dose estimates were calculated for both groups. RESULTS. Interreader agreement was good for permeability (intraclass correlation coefficient [ICC] =.812) and blood flow (ICC = 0.849) and excellent for blood volume (ICC = 0.956), iodine density (ICC = 0.961), and iodine ratio (ICC = 0.956). Very strong positive correlations were found between blood volume and iodine density (p < 0.001) and between blood volume and iodine ratio (p < 0.001). Strong positive correlations were found between blood flow and iodine density (p < 0.001) and between blood flow and iodine ratio (p < 0.001). The correlations between permeability and iodine density (p = 0.01) and between permeability and iodine ratio (p = 0.02) were moderate. The mean size-specific dose estimate of triple-bolus DECT was approximately 15 times lower than that of PCT (p < 0.001). CONCLUSION. Quantitative iodine metrics derived from triple-bolus DECT showed significant correlation with CT parameters in renal cell carcinoma, with a significantly lower radiation dose.
Collapse
|
25
|
Skornitzke S, Kauczor HU, Stiller W. Measuring Dynamic CT Perfusion Based on Time-Resolved Quantitative DECT Iodine Maps: Comparison to Conventional Perfusion at 80 kVp for Pancreatic Carcinoma. Invest Radiol 2019; 54:689-696. [PMID: 31335633 DOI: 10.1097/rli.0000000000000591] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVES Using dual-energy computed tomography (DECT) for quantifying iodine content after injection of contrast agent could provide a quantitative basis for dynamic computed tomography (CT) perfusion measurements by means of established mathematical models of contrast agent kinetics, thus improving results by combining the strength of both techniques, which was investigated in this study. MATERIALS AND METHODS A dynamic DECT acquisition over 51 seconds performed at 80/Sn140 kVp in 17 patients with pancreatic carcinoma was used to calculate iodine-enhancement images for each time point by means of 3-material decomposition. After motion correction, perfusion maps of blood flow were calculated using the maximum-slope model from both 80 kVp image data and iodine-enhancement images. Blood flow was measured in regions of interest placed in healthy pancreatic tissue and carcinoma for both of the derived perfusion maps. To assess image quality of input data, an adjusted contrast-to-noise ratio was calculated for 80 kVp images and iodine-enhancement images. Susceptibility of perfusion results to residual patient breathing motion during acquisition was investigated by measuring blood flow in fatty tissue surrounding the pancreas, where blood flow should be negligible compared with the pancreas. RESULTS For both 80 kVp and iodine-enhancement images, blood flow was significantly higher in healthy tissue (114.2 ± 37.4 mL/100 mL/min or 115.1 ± 36.2 mL/100 mL/min, respectively) than in carcinoma (46.5 ± 26.6 mL/100 mL/min or 49.7 ± 24.7 mL/100 mL/min, respectively). Differences in blood flow between 80 kVp image data and iodine-enhancement images were statistically significant in healthy tissue, but not in carcinoma. For 80 kVp images, adjusted contrast-to-noise ratio was significantly higher (1.3 ± 1.1) than for iodine-enhancement images (1.1 ± 0.9). When evaluating fatty tissue surrounding the pancreas for estimating influence of patient motion, measured blood flow was significantly lower for iodine-enhancement images (30.7 ± 12.0 mL/100 mL/min) than for 80 kVp images (39.0 ± 19.1 mL/100 mL/min). Average patient radiation exposure was 8.01 mSv for dynamic DECT acquisition, compared with 4.60 mSv for dynamic 80 kVp acquisition. DISCUSSION Iodine enhancement images can be used to calculate CT perfusion maps of blood flow, and compared with 80 kVp images, results showed only a small difference of 1 mL/100 mL/min in blood flow in healthy tissue, whereas patient radiation exposure was increased for dynamic DECT. Perfusion maps calculated based on iodine-enhancement images showed lower blood flow in fatty tissues surrounding the pancreas, indicating reduced susceptibility to residual patient breathing motion during the acquisition.
Collapse
Affiliation(s)
- Stephan Skornitzke
- From the Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | | | | |
Collapse
|
26
|
Dose Optimization of Perfusion-derived Response Assessment in Hepatocellular Carcinoma Treated with Transarterial Chemoembolization: Comparison of Volume Perfusion CT and Iodine Concentration. Acad Radiol 2019; 26:1154-1163. [PMID: 30482626 DOI: 10.1016/j.acra.2018.09.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2018] [Revised: 09/27/2018] [Accepted: 09/27/2018] [Indexed: 01/14/2023]
Abstract
RATIONALE AND OBJECTIVES We assessed the value of iodine concentration (IC) as a perfusion-derived response marker for hepatocellular carcinoma (HCC) treated with transarterial chemoembolization (TACE) in comparison with volume perfusion computed tomography (VPCT) parameters. MATERIALS AND METHODS Forty-one HCC lesions in 32 patients examined before and after TACE were analyzed retrospectively. VPCT-parameters were calculated and lesion iodine-maps were computed using subtraction of the baseline and the scan 7 seconds after aortic peak enhancement from the corresponding 80 kVp-VPCT data set. Modified RECIST was used as standard response criteria. Comparisons were performed using Student's t test for normal distributed data and Mann-Whitney U test for non-normal distributed data. Additionally, correlation analysis, receiver operating characteristics (ROC) and interreader agreement were assessed. RESULTS In responding lesions, mean pre-TACE IC and blood flow (BF) were 131.2 mg/100 mL and 96.7 mL/100 mL/min, decreasing to IC 25.6 mg/100 mL (P < 0.001) and BF 28.5 mL/100 mL/min (P < 0.001) post-TACE. In nonresponding lesions, the values remained almost unchanged: pre-TACE: mean BF 79.3 mL/100 mL/min and mean IC 90.4 mg/100 mL; post-TACE: mean BF 71.3 mL/100 mL/min (n.s.) and mean IC 105.4 mg/100 mL (n.s.). Differences in IC-values revealed a high sensitivity/specificity of 96.7%/81.8%. IC and VPCT-parameters showed strong, positive correlations. Mean volume CT dose index for VPCT was 63.4 mGy and 4.9 mGy for iodine maps. CONCLUSION Thus, IC is a meaningful perfusion marker for local therapy response monitoring in HCC that can be acquired with low radiation dose. This information is important for further therapy response applications using dual and single energy CT.
Collapse
|
27
|
Mellnick VM. Invited Commentary on "Spectral CT Imaging in the Differential Diagnosis of Small Bowel Adenocarcinoma From Primary Small Intestinal Lymphoma". Acad Radiol 2019; 26:e131-e133. [PMID: 30967333 DOI: 10.1016/j.acra.2019.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Accepted: 03/07/2019] [Indexed: 12/11/2022]
Affiliation(s)
- Vincent M Mellnick
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 South Kingshighway Blvd, Campus Box 8131, Saint Louis, MO 63110.
| |
Collapse
|
28
|
Lennartz S, Abdullayev N, Zopfs D, Borggrefe J, Neuhaus VF, Persigehl T, Haneder S, Große Hokamp N. Intra-individual consistency of spectral detector CT-enabled iodine quantification of the vascular and renal blood pool. Eur Radiol 2019; 29:6581-6590. [DOI: 10.1007/s00330-019-06266-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 04/24/2019] [Accepted: 05/06/2019] [Indexed: 01/15/2023]
|
29
|
Böning G, Feldhaus F, Adelt S, Kahn J, Fehrenbach U, Streitparth F. Clinical routine use of virtual monochromatic datasets based on spectral CT in patients with hypervascularized abdominal tumors - evaluation of effectiveness and efficiency. Acta Radiol 2019; 60:425-432. [PMID: 29950111 DOI: 10.1177/0284185118786077] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND Virtual monochromatic images (VMI) generated using spectral computed tomography (CT) are promising recently available tools to improve diagnostic performance in oncologic patients. PURPOSE To investigate if virtual monochromatic datasets are suitable for clinical routine use in patients with hypervascularized abdominal tumors. MATERIAL AND METHODS A total of 41 patients with hypervascularized hepatocellular carcinoma (HCC), renal cell carcinoma (RCC), or neuroendocrine tumors (NET) were enrolled in the study; 451 CT series were analyzed. In an intra-individual study design, virtual monochromatic datasets of the arterial phase of each scan were computed. Image quality was assessed objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) and subjectively by using five-point Likert-scales. The volume CT dose index (CTDIvol) was taken from each radiation dose report. The increase in reading time was estimated from the increase in the number of images. RESULTS Intra-individual comparison of the spectral mode in the arterial phase with the portal venous phase revealed no significant increase in the applied dose. SNR, CNRtumor-to-liver , and CNRtumor-to-muscle were significantly increased by lowering virtual monochromatic energy. Subjective image quality scores revealed an increase of contrast in low energy datasets, resulting in significantly higher diagnostic confidence, but an increased image noise at low energies. While diagnostic confidence improved, taking all datasets into account resulted in a significantly longer estimated reading time. CONCLUSION In clinical practice, the use of low energy VMI improved diagnostic confidence without a significant increase in dose. The main disadvantage is a decrease in efficiency due to longer reading times.
Collapse
Affiliation(s)
- Georg Böning
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Felix Feldhaus
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Sebastian Adelt
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes Kahn
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Uli Fehrenbach
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Florian Streitparth
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
30
|
García-Figueiras R, Baleato-González S, Padhani AR, Luna-Alcalá A, Vallejo-Casas JA, Sala E, Vilanova JC, Koh DM, Herranz-Carnero M, Vargas HA. How clinical imaging can assess cancer biology. Insights Imaging 2019; 10:28. [PMID: 30830470 PMCID: PMC6399375 DOI: 10.1186/s13244-019-0703-0] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 11/08/2018] [Indexed: 02/07/2023] Open
Abstract
Human cancers represent complex structures, which display substantial inter- and intratumor heterogeneity in their genetic expression and phenotypic features. However, cancers usually exhibit characteristic structural, physiologic, and molecular features and display specific biological capabilities named hallmarks. Many of these tumor traits are imageable through different imaging techniques. Imaging is able to spatially map key cancer features and tumor heterogeneity improving tumor diagnosis, characterization, and management. This paper aims to summarize the current and emerging applications of imaging in tumor biology assessment.
Collapse
Affiliation(s)
- Roberto García-Figueiras
- Department of Radiology, Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706, Santiago de Compostela, Spain.
| | - Sandra Baleato-González
- Department of Radiology, Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706, Santiago de Compostela, Spain
| | - Anwar R Padhani
- Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England, HA6 2RN, UK
| | - Antonio Luna-Alcalá
- Department of Radiology, University Hospitals of Cleveland, Case Western Reserve University, Cleveland, OH, USA
- MRI Unit, Clínica Las Nieves, Health Time, Jaén, Spain
| | - Juan Antonio Vallejo-Casas
- Unidad de Gestión Clínica de Medicina Nuclear. IMIBIC. Hospital Reina Sofía. Universidad de Córdoba, Córdoba, Spain
| | - Evis Sala
- Department of Radiology and Cancer Research UK Cambridge Center, Cambridge, CB2 0QQ, UK
| | - Joan C Vilanova
- Department of Radiology, Clínica Girona and IDI, Lorenzana 36, 17002, Girona, Spain
| | - Dow-Mu Koh
- Department of Radiology, Royal Marsden Hospital & Institute of Cancer Research, Fulham Road, London, SW3 6JJ, UK
| | - Michel Herranz-Carnero
- Nuclear Medicine Department, Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706, Santiago de Compostela, Galicia, Spain
- Molecular Imaging Program, IDIS, USC, Santiago de Compostela, Galicia, Spain
| | - Herbert Alberto Vargas
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, Radiology, 1275 York Av. Radiology Academic Offices C-278, New York, NY, 10065, USA
| |
Collapse
|
31
|
Lu X, Lu Z, Yin J, Gao Y, Chen X, Guo Q. Effects of radiation dose levels and spectral iterative reconstruction levels on the accuracy of iodine quantification and virtual monochromatic CT numbers in dual-layer spectral detector CT: an iodine phantom study. Quant Imaging Med Surg 2019; 9:188-200. [PMID: 30976543 DOI: 10.21037/qims.2018.11.12] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Background The purpose of this study is to investigate the accuracy of iodine quantification and virtual monochromatic CT numbers obtained with the dual-layer spectral CT (DLCT) using a phantom at different radiation dose levels and spectral iterative reconstruction (IR) levels. Methods An abdomen phantom with seven iodine inserts (2.0, 2.5, 5.0, 7.5, 10.0, 15.0, 20.0 mg/mL) was imaged using a DLCT scanner. Five repeated scans were performed at computed tomography dose index volume (CTDIvol) levels of 5, 10, 15, 20, 25 mGy at tube voltages of 120 and 140 kVp, respectively. Spectral-based images were reconstructed using four spectral IR levels (spectral level of 0, 2, 4, 6). Iodine density images and virtual monochromatic images (VMI) at energy levels of 50, 70 and 120 keV were created. The absolute percentage bias (APB) of the measured iodine concentration and the true iodine concentration, and the measured VMI CT numbers and the theoretical VMI CT numbers were compared to determine the difference of radiation dose levels and different spectral IR levels. Results At CTDIvol levels of 25, 20, 15, 10 mGy, radiation dose levels had no effect on the accuracy of iodine quantitation; at CTDIvol level of 5 mGy, the accuracy of iodine quantification was the poorest, with the mean APBiodine of 4.33% (P<0.05). There was no significant difference in the accuracy of iodine quantitation between 120 and 140 kVp (P=0.648). At energy levels of 50, 70 and 120 keV, there was no significant difference in the accuracy of the VMI CT numbers among the CTDIvol levels of 25, 20 and 15 mGy. However, the accuracy of VMI CT numbers was significantly degraded at the CTDIvol levels of 10 and 5 mGy (P<0.05). At energy level of 50 keV, the accuracy of VMI CT numbers was not affected by tube voltages (kVps) used (P=0.125). At the energy levels of 70 and 120 keV, 140 kVp produced a smaller bias than 120 kVp, with the mean APBHU at 120 and 140 kVp being of 3.62% vs. 2.99% for 70 keV (P<0.01), and 11.65% vs. 9.28% for 120 keV (P<0.01), respectively. Spectral IR levels did not affect the accuracy of iodine quantification and VMI CT numbers (P=0.998, P=0.963). Conclusions The accuracy of iodine quantification and VMI CT numbers was only affected by very low radiation dose levels. At the clinically applied radiation dose levels of >10 mGy, the accuracy of both iodine quantification and VMI CT numbers is relatively stable and high.
Collapse
Affiliation(s)
- Xiaomei Lu
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China
| | - Zaiming Lu
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China
| | - Jiandong Yin
- Division of Biomedical Engineering, China Medical University, Shenyang 110001, China
| | - Yuying Gao
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China
| | - Xingbiao Chen
- CT Clinical Science, Philips Healthcare, Shanghai 200233, China
| | - Qiyong Guo
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China
| |
Collapse
|
32
|
Effect of CT Acquisition Parameters on Iodine Density Measurement at Dual-Layer Spectral CT. AJR Am J Roentgenol 2018; 211:748-754. [PMID: 30085834 DOI: 10.2214/ajr.17.19381] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE We aimed to evaluate the effect of tube voltage, tube current-time product, and iterative reconstruction on iodine quantification using a dual-layer spectral CT scanner. MATERIALS AND METHODS Two mediastinal iodine phantoms, each containing six tubes of different iodine concentrations (0, 1, 2.5, 5, 10, and 20 mg I/mL; the two phantoms had tubes with contrast media diluted in water and in 10% amino acid solution, respectively), were inserted into an anthropomorphic chest phantom and scanned with varying acquisition parameters (120 and 140 kVp; 20, 40, 60, 80, 100, 150, and 200 mAs; and spectral reconstruction levels 0 and 6). Thereafter, iodine density was measured (in milligrams of iodine per milliliter) using a dedicated software program, and the effect of acquisition parameters on iodine density and on its relative measurement error (RME) was analyzed using a linear mixed-effects model. RESULTS Tube voltages (all, p < 0.001) and tube current-time products (p < 0.05, depending on the interaction terms for iodine density; p = 0.023 for RME) had statistically significant effects on iodine density and RME. However, the magnitude of their effects was minimal. That is, estimated differences between tube voltage settings ranged from 0 to 0.8 mg I/mL for iodine density and from 1.0% to 4.2% for RME. For tube current-time product, alteration of 100 mAs caused changes in iodine density and RME of approximately 0.1 mg I/mL and 0.6%, respectively. Spectral level was not an affecting factor for iodine quantification (p = 0.647 for iodine density and 0.813 for RME). CONCLUSION Iodine quantification using dual-layer spectral CT was feasible irrespective of CT acquisition parameters because their effects on iodine density and RME were minimal.
Collapse
|
33
|
Morgan DE. The Role of Dual-Energy Computed Tomography in Assessment of Abdominal Oncology and Beyond. Radiol Clin North Am 2018; 56:565-585. [PMID: 29936948 DOI: 10.1016/j.rcl.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The added value and strength of dual energy computed tomography for the evaluation of oncologic patients revolve around the use of lower energy reconstructed images and iodine material density images. Lower keV simulated monoenergetic images optimize soft tissue tumor to nontumoral attenuation differences and increase contrast to noise ratios to improve lesion detection. Iodine material density images or maps are helpful from a qualitative standpoint for image interpretation because they result in improved detection and characterization of tumors and lymph node involvement, and from a quantitative assessment by enabling interrogation of specific properties of tissues to predict and assess therapeutic response.
Collapse
Affiliation(s)
- Desiree E Morgan
- Department of Radiology University of Alabama at Birmingham, 619 19th Street South, JTN 456, Birmingham, AL 35249-6830, USA.
| |
Collapse
|
34
|
Vande Lune P, Abdel Aal AK, Klimkowski S, Zarzour JG, Gunn AJ. Hepatocellular Carcinoma: Diagnosis, Treatment Algorithms, and Imaging Appearance after Transarterial Chemoembolization. J Clin Transl Hepatol 2018; 6:175-188. [PMID: 29951363 PMCID: PMC6018317 DOI: 10.14218/jcth.2017.00045] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 11/02/2017] [Accepted: 12/02/2017] [Indexed: 02/07/2023] Open
Abstract
Hepatocellular carcinoma (HCC) is a common cause of cancer-related death, with incidence increasing worldwide. Unfortunately, the overall prognosis for patients with HCC is poor and many patients present with advanced stages of disease that preclude curative therapies. Diagnostic and interventional radiologists play a key role in the management of patients with HCC. Diagnostic radiologists can use contrast-enhanced computed tomography (CT), magnetic resonance imaging, and ultrasound to diagnose and stage HCC, without the need for pathologic confirmation, by following established criteria. Once staged, the interventional radiologist can treat the appropriate patients with percutaneous ablation, transarterial chemoembolization, or radioembolization. Follow-up imaging after these liver-directed therapies for HCC can be characterized according to various radiologic response criteria; although, enhancement-based criteria, such as European Association for the Study of the Liver and modified Response Evaluation Criteria in Solid Tumors, are more reflective of treatment effect in HCC. Newer imaging technologies like volumetric analysis, dual-energy CT, cone beam CT and perfusion CT may provide additional benefits for patients with HCC.
Collapse
Affiliation(s)
- Patrick Vande Lune
- University of Alabama at Birmingham School of Medicine, Birmingham, AL, USA
| | - Ahmed K. Abdel Aal
- Division of Vascular and Interventional Radiology, Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Sergio Klimkowski
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Jessica G. Zarzour
- Division of Abdominal Imaging, Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Andrew J. Gunn
- Division of Vascular and Interventional Radiology, Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
- *Correspondence to: Andrew J. Gunn, Division of Vascular and Interventional Radiology, Department of Radiology, University of Alabama at Birmingham, 619 19 St S, NHB 623, Birmingham, AL 35249, USA. Tel: +1-205-975-4850, Fax: +1-205-975-5257, E-mail:
| |
Collapse
|
35
|
Li J, Fang M, Wang R, Dong D, Tian J, Liang P, Liu J, Gao J. Diagnostic accuracy of dual-energy CT-based nomograms to predict lymph node metastasis in gastric cancer. Eur Radiol 2018; 28:5241-5249. [DOI: 10.1007/s00330-018-5483-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/05/2018] [Accepted: 04/12/2018] [Indexed: 02/07/2023]
|
36
|
Skornitzke S, Fritz F, Mayer P, Koell M, Hansen J, Pahn G, Hackert T, Kauczor HU, Stiller W. Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking. Br J Radiol 2018; 91:20170351. [PMID: 29446319 DOI: 10.1259/bjr.20170351] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
OBJECTIVE Quantitative evaluation of different bolus tracking trigger delays for acquisition of dual energy (DE) CT iodine maps as an alternative to CT perfusion. METHODS Prior to this retrospective analysis of prospectively acquired data, DECT perfusion sequences were dynamically acquired in 22 patients with pancreatic carcinoma using dual source CT at 80/140 kVp with tin filtration. After deformable motion-correction, perfusion maps of blood flow (BF) were calculated from 80 kVp image series of DECT, and iodine maps were calculated for each of the 34 DECT acquisitions per patient. BF and iodine concentrations were measured in healthy pancreatic tissue and carcinoma. To evaluate potential DECT acquisition triggered by bolus tracking, measured iodine concentrations from the 34 DECT acquisitions per patient corresponding to different trigger delays were assessed for correlation to BF and intergroup differences between tissue types depending on acquisition time. RESULTS Average BF measured in healthy pancreatic tissue and carcinoma was 87.6 ± 28.4 and 38.6 ± 22.2 ml/100 ml min-1, respectively. Correlation between iodine concentrations and BF was statistically significant for bolus tracking with trigger delay greater than 0 s (rmax = 0.89; p < 0.05). Differences in iodine concentrations between healthy pancreatic tissue and carcinoma were statistically significant for DECT acquisitions corresponding to trigger delays of 15-21 s (p < 0.05). CONCLUSION An acquisition window between 15 and 21 s after exceeding bolus tracking threshold shows promising results for acquisition of DECT iodine maps as an alternative to CT perfusion measurements of BF. Advances in knowledge: After clinical validation, DECT iodine maps of pancreas acquired using bolus tracking with appropriate trigger delay as determined in this study could offer an alternative quantitative imaging biomarker providing functional information for tumor assessment at reduced patient radiation exposure compared to CT perfusion measurements of BF.
Collapse
Affiliation(s)
- Stephan Skornitzke
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Franziska Fritz
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Philipp Mayer
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Marco Koell
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Jens Hansen
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Gregor Pahn
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Thilo Hackert
- 2 General Visceral and Transplantation Surgery, University Hospital Heidelberg , Heidelberg , Germany
| | - Hans-Ulrich Kauczor
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Wolfram Stiller
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| |
Collapse
|
37
|
Mulé S, Pigneur F, Quelever R, Tenenhaus A, Baranes L, Richard P, Tacher V, Herin E, Pasquier H, Ronot M, Rahmouni A, Vilgrain V, Luciani A. Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma? Eur Radiol 2017; 28:1977-1985. [PMID: 29168007 DOI: 10.1007/s00330-017-5151-y] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 10/14/2017] [Accepted: 10/19/2017] [Indexed: 12/29/2022]
Abstract
OBJECTIVES To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. METHODS In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) < 0.05 was considered significant. RESULTS Mean HCC late-arterial and portal iodine concentrations were 22.7±12.7 mg/mL and 18.7±8.3 mg/mL, respectively. Late-arterial iodine concentration was significantly related to BV (mixed-effects model F statistic (F)=28.52, p<0.0001), arterial BF (aBF, F=17.62, p<0.0001), hepatic perfusion index (F=28.24, p<0.0001), positive enhancement integral (PEI, F=66.75, p<0.0001) and mean slope of increase (F=32.96, p<0.0001), while portal-venous iodine concentration was mainly related to BV (F=29.68, p<0.0001) and PEI (F=66.75, p<0.0001). CONCLUSIONS In advanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. KEY POINTS • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.
Collapse
Affiliation(s)
- Sébastien Mulé
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France.
| | - Frédéric Pigneur
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France
| | - Ronan Quelever
- GE Healthcare, 283 rue de la Minière, 78530, Buc, France
| | - Arthur Tenenhaus
- Laboratoire des Signaux et Systèmes, Université Paris-Saclay, Orsay, France.,Biostatistics and bioinformatics core facility, Brain and Spine Institute, Paris, France
| | - Laurence Baranes
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France
| | | | - Vania Tacher
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France.,Faculté de Médecine, Université Paris Est Creteil, Creteil, France.,, INSERM IMRB, U 955, Equipe 18, Creteil, France
| | - Edouard Herin
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France
| | - Hugo Pasquier
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France.,Faculté de Médecine, Université Paris Est Creteil, Creteil, France
| | - Maxime Ronot
- Service de Radiologie, AP-HP, Hôpitaux Universitaires Paris Nord Val de Seine, Beaujon, 100 boulevard General Leclerc, 92118, Clichy, France.,Université Paris Diderot, Sorbonne Paris Cité, Paris, France.,INSERM U1149, centre de recherche biomédicale Bichat-Beaujon, CRB3, Paris, France
| | - Alain Rahmouni
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France.,Faculté de Médecine, Université Paris Est Creteil, Creteil, France
| | - Valérie Vilgrain
- Service de Radiologie, AP-HP, Hôpitaux Universitaires Paris Nord Val de Seine, Beaujon, 100 boulevard General Leclerc, 92118, Clichy, France.,Université Paris Diderot, Sorbonne Paris Cité, Paris, France.,INSERM U1149, centre de recherche biomédicale Bichat-Beaujon, CRB3, Paris, France
| | - Alain Luciani
- Service d'Imagerie Médicale, AP-HP, Hôpitaux Universitaires Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Creteil Cedex, France.,Faculté de Médecine, Université Paris Est Creteil, Creteil, France.,, INSERM IMRB, U 955, Equipe 18, Creteil, France
| |
Collapse
|
38
|
Chen X, Xu Y, Duan J, Li C, Sun H, Wang W. Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer. Medicine (Baltimore) 2017; 96:e7479. [PMID: 28700488 PMCID: PMC5515760 DOI: 10.1097/md.0000000000007479] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100 mL), and a perfusion index (PI = PF/[PF + AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (λ) and the slope (λHU). λ was defined as the difference of CT values between 40 and 70 KeV monochromatic images in lung lesions. λHU was calculated by the following equation: λHU = |λ/(70 - 40)|. The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively.All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (λ, λHU) were relatively good to excellent (intraclass correlation coefficient [ICC]Inter = 0.8726-0.9255, ICCInter = 0.8179-0.8842; ICCInter = 0.8881-0.9177, ICCInter = 0.9820-0.9970, ICCInter = 0.9780-0.9971, respectively). Correlation coefficient between λ and AF, and PF were as follows: 0.589 (P < .01) and 0.383 (P < .05). Correlation coefficient between λHU and AF, and PF were as follows: 0.564 (P < .01) and 0.388 (P < .05).Both the single-source DE-CT and dual-input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion parameters derived from DI-PCT.
Collapse
|
39
|
Shi C, Zhang H, Yan J, Wang B, Du L, Pan Z, Yan F. Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study. Eur Radiol 2017; 27:671-680. [PMID: 27271924 PMCID: PMC5209438 DOI: 10.1007/s00330-016-4442-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 03/31/2016] [Accepted: 05/23/2016] [Indexed: 12/21/2022]
Abstract
OBJECTIVES To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT). METHODS 31 EGC patients (19 men, 12 women; age range, 38-81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally reconstructed polyenergetic images (PEIs) at 120 kV and virtual monoenergetic images (MEIs) and AMEIs at six different kiloelectron volt (keV) levels (from 40 to 90 keV) were evaluated from the 100 and Sn 140 kV dual energy image data, respectively. The visibility and stage migration of EGC for all three image data sets were evaluated and statistically analyzed. The objective and subjective image qualities were also evaluated. RESULTS AMEIs at 40 keV showed the best visibility (80.7 %) and the lowest stage migration (35.5 %) for EGC. The stage migration for AMEIs at 40 keV was significantly lower than that for PEIs (p = 0.026). AMEIs at 40 keV had statistically higher CNR in the arterial and portal phases, gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05). CONCLUSIONS AMEIs at 40 keV with MPR increase the CNR of EGC and thus potentially lower the stage migration of EGC. KEY POINTS • AMEIs benefits from the recombination of low-keV images and medium energies. • AMEIs could receive better CNR results than MEIs. • AMEIs at 40 keV potentially lower the stage migration of EGC.
Collapse
Affiliation(s)
- Cen Shi
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197, Ruijin 2nd Road, Shanghai, 200025, China
- Department of Radiology, the First Affiliated Hospital of Soochow University, 188 Shizi Road, Suzhou, 215006, China
| | - Huan Zhang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197, Ruijin 2nd Road, Shanghai, 200025, China.
| | - Jing Yan
- Siemens Medical System, Shanghai, 201318, China
| | - Baisong Wang
- Department of biological statistics, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Lianjun Du
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197, Ruijin 2nd Road, Shanghai, 200025, China
| | - Zilai Pan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197, Ruijin 2nd Road, Shanghai, 200025, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197, Ruijin 2nd Road, Shanghai, 200025, China
| |
Collapse
|
40
|
Zhu L, Wu WM, Xue HD, Liu W, Wang X, Sun H, Li P, Zhao YP, Jin ZY. Sporadic insulinomas on volume perfusion CT: dynamic enhancement patterns and timing of optimal tumour–parenchyma contrast. Eur Radiol 2017; 27:3491-3498. [DOI: 10.1007/s00330-016-4709-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2016] [Revised: 11/30/2016] [Accepted: 12/15/2016] [Indexed: 12/13/2022]
|
41
|
Lv P, Liu J, Yan X, Chai Y, Chen Y, Gao J, Pan Y, Li S, Guo H, Zhou Y. CT spectral imaging for monitoring the therapeutic efficacy of VEGF receptor kinase inhibitor AG-013736 in rabbit VX2 liver tumours. Eur Radiol 2016; 27:918-926. [PMID: 27287476 DOI: 10.1007/s00330-016-4458-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 04/21/2016] [Accepted: 05/30/2016] [Indexed: 11/25/2022]
Abstract
PURPOSE The aim of this study was to evaluate the value of computed tomography (CT) spectral imaging in assessing the therapeutic efficacy of a vascular endothelial growth factor (VEGF) receptor inhibitor AG-013736 in rabbit VX2 liver tumours. METHODS Twenty-three VX2 liver tumour-bearing rabbits were scanned with CT in spectral imaging mode during the arterial phase (AP) and portal phase (PP). The iodine concentrations(ICs)of tumours normalized to aorta (nICs) at different time points (baseline, 2, 4, 7, 10, and 14 days after treatment) were compared within the treated group (n = 17) as well as between the control (n = 6) and treated groups. Correlations between the tumour size, necrotic fraction (NF), microvessel density (MVD), and nICs were analysed. RESULTS The change of nICs relative to baseline in the treated group was lower compared to the control group. A greater decrease in the nIC of a tumour at 2 days was positively correlated with a smaller increase in tumour size at 14 days (P < 0.05 for both). The tumour nIC values in AP and PP had correlations with MVD (r = 0.71 and 0.52) and NF (r = -0.54 and -0.51) (P < 0.05 for all). CONCLUSIONS CT spectral imaging allows for the evaluation and early prediction of tumour response to AG-013736. KEY POINTS • AG-013736 treatment response was evaluated by CT in a rabbit tumour model. • CT spectral imaging allows for the early treatment monitoring of targeted anti-tumour therapies. • Spectral CT findings correlated with vascular changes after anti-tumour therapies. • Spectral CT is a promising method for assessing clinical treatment response.
Collapse
Affiliation(s)
- Peijie Lv
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Xiaopeng Yan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Yaru Chai
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Yan Chen
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052.
| | - Yuanwei Pan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Shuai Li
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Hua Guo
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| | - Yue Zhou
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, East Jianshe Road, Zhengzhou, Henan Province, China, 450052
| |
Collapse
|
42
|
Yang K, Zhang XM, Yang L, Xu H, Peng J. Advanced imaging techniques in the therapeutic response of transarterial chemoembolization for hepatocellular carcinoma. World J Gastroenterol 2016; 22:4835-4847. [PMID: 27239110 PMCID: PMC4873876 DOI: 10.3748/wjg.v22.i20.4835] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Revised: 03/29/2016] [Accepted: 04/20/2016] [Indexed: 02/07/2023] Open
Abstract
Hepatocellular carcinoma (HCC) is one of the major causes of morbidity and mortality in patients with chronic liver disease. Transarterial chemoembolization (TACE) can significantly improve the survival rate of patients with HCC and is the first treatment choice for patients who are not suitable for surgical resections. The evaluation of the response to TACE treatment affects not only the assessment of the therapy efficacy but also the development of the next step in the treatment plan. The use of imaging to examine changes in tumor volume to assess the response of solid tumors to treatment has been controversial. In recent years, the emergence of new imaging technology has made it possible to observe the response of tumors to treatment prior to any morphological changes. In this article, the advances in studies reporting the use of computed tomography perfusion imaging, diffusion-weighted magnetic resonance imaging (MRI), intravoxel incoherent motion, diffusion kurtosis imaging, magnetic resonance spectroscopy, magnetic resonance perfusion-weighted imaging, blood oxygen level-dependent MRI, positron emission tomography (PET)/computed tomography and PET/MRI to assess the TACE treatment response are reviewed.
Collapse
|