1
|
Skornitzke S, Mergen V, Biederer J, Alkadhi H, Do TD, Stiller W, Frauenfelder T, Kauczor HU, Euler A. Metal Artifact Reduction in Photon-Counting Detector CT: Quantitative Evaluation of Artifact Reduction Techniques. Invest Radiol 2024; 59:442-449. [PMID: 37812482 DOI: 10.1097/rli.0000000000001036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2023]
Abstract
OBJECTIVES With the introduction of clinical photon-counting detector computed tomography (PCD-CT) and its novel reconstruction techniques, a quantitative investigation of different acquisition and reconstruction settings is necessary to optimize clinical acquisition protocols for metal artifact reduction. MATERIALS AND METHODS A multienergy phantom was scanned on a clinical dual-source PCD-CT (NAEOTOM Alpha; Siemens Healthcare GmbH) with 4 different central inserts: water-equivalent plastic, aluminum, steel, and titanium. Acquisitions were performed at 120 kVp and 140 kVp (CTDI vol 10 mGy) and reconstructed as virtual monoenergetic images (VMIs; 110-150 keV), as T3D, and with the standard reconstruction "none" (70 keV VMI) using different reconstruction kernels (Br36, Br56) and with as well as without iterative metal artifact reduction (iMAR). Metal artifacts were quantified, calculating relative percentages of metal artifacts. Mean CT numbers of an adjacent water-equivalent insert and different tissue-equivalent inserts were evaluated, and eccentricity of metal rods was measured. Repeated-measures analysis of variance was performed for statistical analysis. RESULTS Metal artifacts were most prevalent for the steel insert (12.6% average artifacts), followed by titanium (4.2%) and aluminum (1.0%). The strongest metal artifact reduction was noted for iMAR (with iMAR: 1.4%, without iMAR: 10.5%; P < 0.001) or VMI (VMI: 110 keV 2.6% to 150 keV 3.3%, T3D: 11.0%, and none: 16.0%; P < 0.001) individually, with best results when combining iMAR and VMI at 110 keV (1.2%). Changing acquisition tube potential (120 kV: 6.6%, 140 kV: 5.2%; P = 0.33) or reconstruction kernel (Br36: 5.5%, Br56: 6.4%; P = 0.17) was less effective. Mean CT numbers and standard deviations were significantly affected by iMAR (with iMAR: -3.0 ± 21.5 HU, without iMAR: -8.5 ± 24.3 HU; P < 0.001), VMI (VMI: 110 keV -3.6 ± 21.6 HU to 150 keV -1.4 ± 21.2 HU, T3D: -11.7 ± 23.8 HU, and none: -16.9 ± 29.8 HU; P < 0.001), tube potential (120 kV: -4.7 ± 22.8 HU, 140 kV: -6.8 ± 23.0 HU; P = 0.03), and reconstruction kernel (Br36: -5.5 ± 14.2 HU, Br56: -6.8 ± 23.0 HU; P < 0.001). Both iMAR and VMI improved quantitative CT number accuracy and metal rod eccentricity for the steel rod, but iMAR was of limited effectiveness for the aluminum rod. CONCLUSIONS For metal artifact reduction in PCD-CT, a combination of iMAR and VMI at 110 keV demonstrated the strongest artifact reduction of the evaluated options, whereas the impact of reconstruction kernel and tube potential was limited.
Collapse
Affiliation(s)
- Stephan Skornitzke
- From the Heidelberg University Hospital, Clinic for Diagnostic and Interventional Radiology, Heidelberg, Germany (S.S., J.B., T.D.D., W.S., and H.-U.K.); Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (V.M., H.A., T.F., and A.E.); Translational Lung Research Center Heidelberg, Member of the German Lung Research Center, Heidelberg, Germany (J.B., W.S., H.-U.K.); University of Latvia, Faculty of Medicine, Riga, Latvia (J.B.); Christian-Albrechts-Universität zu Kiel, Faculty of Medicine, Kiel, Germany (J.B.); and Kantonsspital Baden, Radiologie Baden, Baden, Switzerland (A.E.)
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Hao W, Xu Z, Lin H, Yan F. Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study. Acad Radiol 2024:S1076-6332(24)00281-2. [PMID: 38772799 DOI: 10.1016/j.acra.2024.04.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 04/21/2024] [Accepted: 04/26/2024] [Indexed: 05/23/2024]
Abstract
RATIONALE AND OBJECTIVES To evaluate the feasibility of using photon-counting detector computed tomography (PCD CT) to simultaneously quantify fat and iron content MATERIALS AND METHODS: Phantoms with pure fat, pure iron and fat-iron deposition were scanned by two tube voltages (120 and 140 kV) and two image quality (IQ) settings (80 and 145). Using an iron-specific three-material decomposition algorithm, virtual noniron (VNI) and virtual iron content (VIC) images were generated at quantum iterative reconstruction (QIR) strength levels 1-4. RESULTS Significant linear correlations were observed between known fat content (FC) and VNI for pure fat phantoms (r = 0.981-0.999, p < 0.001) and between known iron content (IC) and VIC for pure iron phantoms (r = 0.897-0.975, p < 0.001). In fat-iron phantoms, the measurement for fat content of 5-30% demonstrated good linearity between FC and VNI (r = 0.919-0.990, p < 0.001), and VNI were not affected by 75, 150, and 225 µmol/g iron overload (p = 0.174-0.519). The measurement for iron demonstrated a linear range of 75-225 µmol/g between IC and VIC (r = 0.961-0.994, p < 0.001) and VIC was not confounded by the coexisting 5%, 20%, and 30% fat deposition (p = 0.943-0.999). The Bland-Altman of fat and iron measurements were not significantly different at varying tube voltages and IQ settings (all p > 0.05). No significant difference in VNI and VIC at QIR 1-4. CONCLUSION PCD CT can accurately and simultaneously quantify fat and iron, including scan parameters with lower radiation dose.
Collapse
Affiliation(s)
- Wanting Hao
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China.
| | - Zhihan Xu
- CT Collaboration, Siemens Healthcare Ltd., No. 278 Zhouzhu Road, Shanghai 200025, China.
| | - Huimin Lin
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China.
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China; Faculty of Medical Imaging Technology, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine.
| |
Collapse
|
3
|
Klempka A, Schröder A, Neumayer P, Groden C, Clausen S, Hetjens S. Cranial Computer Tomography with Photon Counting and Energy-Integrated Detectors: Objective Comparison in the Same Patients. Diagnostics (Basel) 2024; 14:1019. [PMID: 38786317 PMCID: PMC11119038 DOI: 10.3390/diagnostics14101019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/10/2024] [Accepted: 05/13/2024] [Indexed: 05/25/2024] Open
Abstract
This study provides an objective comparison of cranial computed tomography (CT) imaging quality and radiation dose between photon counting detectors (PCCTs) and energy-integrated detectors (EIDs). We retrospectively analyzed 158 CT scans from 76 patients, employing both detector types on the same individuals to ensure a consistent comparison. Our analysis focused on the Computed Tomography Dose Index and the Dose-Length Product together with the contrast-to-noise ratio and the signal-to-noise ratio for brain gray and white matter. We utilized standardized imaging protocols and consistent patient positioning to minimize variables. PCCT showed a potential for higher image quality and lower radiation doses, as highlighted by this study, thus achieving diagnostic clarity with reduced radiation exposure, underlining its significance in patient care, particularly for patients requiring multiple scans. The results demonstrated that while both systems were effective, PCCT offered enhanced imaging and patient safety in neuroradiological evaluations.
Collapse
Affiliation(s)
- Anna Klempka
- Department of Neuroradiology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Alexander Schröder
- Department of Neuroradiology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Philipp Neumayer
- Department of Neuroradiology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Christoph Groden
- Department of Neuroradiology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Sven Clausen
- Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Svetlana Hetjens
- Department of Medical Statistics and Biomathematics, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| |
Collapse
|
4
|
Madhavan AA, Bathla G, Benson JC, Diehn FE, Nagelschneider AA, Lehman VT. High yield clinical applications for photon counting CT in neurovascular imaging. Br J Radiol 2024; 97:894-901. [PMID: 38460543 DOI: 10.1093/bjr/tqae058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/05/2024] [Accepted: 03/07/2024] [Indexed: 03/11/2024] Open
Abstract
Photon-counting CT (PCCT) uses a novel X-ray detection mechanism that confers many advantages over that used in traditional energy integrating CT. As PCCT becomes more available, it is important to thoroughly understand its benefits and highest yield areas for improvements in diagnosis of various diseases. Based on our early experience, we have identified several areas of neurovascular imaging in which PCCT shows promise. Here, we describe the benefits in diagnosing arterial and venous diseases in the head, neck, and spine. Specifically, we focus on applications in head and neck CT angiography (CTA), spinal CT angiography, and CT myelography for detection of CSF-venous fistulas. Each of these applications highlights the technological advantages of PCCT in neurovascular imaging. Further understanding of these applications will not only benefit institutions incorporating PCCT into their practices but will also help guide future directions for implementation of PCCT for diagnosing other pathologies in neuroimaging.
Collapse
Affiliation(s)
- Ajay A Madhavan
- Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States
| | - Girish Bathla
- Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States
| | - John C Benson
- Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States
| | - Felix E Diehn
- Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States
| | - Alex A Nagelschneider
- Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States
| | - Vance T Lehman
- Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States
| |
Collapse
|
5
|
Obmann MM. Editorial Comment: Stability of Virtual Monoenergetic Images From Photon-Counting Detector CT May Allow Broader Quantitative Applications in Research and Clinical Practice. AJR Am J Roentgenol 2024; 222:e2430986. [PMID: 38380854 DOI: 10.2214/ajr.24.30986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
|
6
|
Fletcher JG, Inoue A, Bratt A, Horst KK, Koo CW, Rajiah PS, Baffour FI, Ko JP, Remy-Jardin M, McCollough CH, Yu L. Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice. Radiology 2024; 310:e231986. [PMID: 38501953 DOI: 10.1148/radiol.231986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.
Collapse
Affiliation(s)
- Joel G Fletcher
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Akitoshi Inoue
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Alex Bratt
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Kelly K Horst
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Chi Wan Koo
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Prabhakar Shantha Rajiah
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Francis I Baffour
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Jane P Ko
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Martine Remy-Jardin
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Cynthia H McCollough
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Lifeng Yu
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| |
Collapse
|
7
|
McCollough CH. Reclassification of Coronary Artery Disease Status Using Photon-counting CT. Radiology 2024; 310:e240098. [PMID: 38376400 DOI: 10.1148/radiol.240098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Affiliation(s)
- Cynthia H McCollough
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905
| |
Collapse
|
8
|
Yalon M, Sae-Kho T, Khanna A, Chang S, Andrist BR, Weber NM, Hoodeshenas S, Ferrero A, Glazebrook KN, McCollough CH, Baffour FI. Staging of breast cancer in the breast and regional lymph nodes using contrast-enhanced photon-counting detector CT: accuracy and potential impact on patient management. Br J Radiol 2024; 97:93-97. [PMID: 38263843 PMCID: PMC11027279 DOI: 10.1093/bjr/tqad042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 01/25/2024] Open
Abstract
OBJECTIVES To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. METHODS Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. RESULTS Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. CONCLUSIONS A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. ADVANCES IN KNOWLEDGE UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.
Collapse
Affiliation(s)
- Mariana Yalon
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Tiffany Sae-Kho
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Akriti Khanna
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Shaojie Chang
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Boleyn R Andrist
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Nikkole M Weber
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Safa Hoodeshenas
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | - Andrea Ferrero
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| | | | | | - Francis I Baffour
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, United States
| |
Collapse
|
9
|
Ogunfuwa FO, Needell S, Simovitch RW. Severe metallosis following catastrophic failure of total shoulder arthroplasty - a case report. Skeletal Radiol 2024:10.1007/s00256-024-04575-w. [PMID: 38236295 DOI: 10.1007/s00256-024-04575-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 01/02/2024] [Accepted: 01/05/2024] [Indexed: 01/19/2024]
Abstract
Metallosis is an unusual but consequential complication arising from orthopedic hardware implantation, characterized by the deposition of metallic particles in the periprosthetic soft tissues. The incidence of metallosis associated with shoulder arthroplasties is exceptionally rare since the shoulder is not a weight-bearing joint, making it less susceptible to mechanical wear and, consequently, to conditions like particle disease and metallosis. Nevertheless, anomalous metal-on-metal interactions can develop in total shoulder arthroplasties if the polyethylene component fails due to wear, fracture, or dissociation. If left unaddressed, metallosis can incite an adverse immune-mediated local tissue response, culminating in joint destruction and adjacent soft tissues and muscle necrosis. In this case report, the diagnosis of metallosis was made in a patient with an anatomic total shoulder arthroplasty using a state-of-the-art photon counting detector CT supplemented by post-processing metal artifact reduction algorithms. This advanced imaging approach was effective in discerning the source of implant failure and in identifying manifestations of severe metallosis including osteolysis and pseudotumor formation. Advanced imaging methods can accurately characterize the severity and extent of metallosis, thereby helping guide surgical planning to mitigate serious complications associated with this condition.
Collapse
Affiliation(s)
- Feyikemi O Ogunfuwa
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA.
| | | | | |
Collapse
|
10
|
Rajiah PS, Alkadhi H, Van Mieghem NM, Budde RPJ. Utility of Photon Counting CT in Transcatheter Structural Heart Disease Interventions. Semin Roentgenol 2024; 59:32-43. [PMID: 38388095 DOI: 10.1053/j.ro.2023.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 02/24/2024]
Affiliation(s)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Nicolas M Van Mieghem
- Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
| |
Collapse
|
11
|
Chamberlin JH, Baruah D, Smith C, McGuire A, Maisuria D, Kabakus IM. Cardiac Computed Tomography Protocols in Structural Heart Disease: A State-of-the-Art Review. Semin Roentgenol 2024; 59:7-19. [PMID: 38388099 DOI: 10.1053/j.ro.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/23/2023] [Accepted: 12/01/2023] [Indexed: 02/24/2024]
Affiliation(s)
- Jordan H Chamberlin
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Dhiraj Baruah
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC.
| | - Carter Smith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Aaron McGuire
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Dhruw Maisuria
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Ismail M Kabakus
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| |
Collapse
|
12
|
Hagen F, Soschynski M, Weis M, Hagar MT, Krumm P, Ayx I, Taron J, Krauss T, Hein M, Ruile P, von Zur Muehlen C, Schlett CL, Neubauer J, Tsiflikas I, Russe MF, Arnold P, Faby S, Froelich MF, Weiß J, Stein T, Overhoff D, Bongers M, Nikolaou K, Schönberg SO, Bamberg F, Horger M. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. ROFO-FORTSCHR RONTG 2024; 196:25-35. [PMID: 37793417 DOI: 10.1055/a-2119-5802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
BACKGROUND Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.
Collapse
Affiliation(s)
- Florian Hagen
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Martin Soschynski
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Meike Weis
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Muhammad Taha Hagar
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Patrick Krumm
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Isabelle Ayx
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Jana Taron
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Tobias Krauss
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Manuel Hein
- Department of Cardiology & Angiology, University Heart Center Freiburg - Bad Krozingen, University Hospital Freiburg, Faculty of medicine, 79106 Freiburg, Germany
| | - Philipp Ruile
- Department of Cardiology & Angiology, University Heart Center Freiburg - Bad Krozingen, University Hospital Freiburg, Faculty of medicine, 79106 Freiburg, Germany
| | - Constantin von Zur Muehlen
- Department of Cardiology & Angiology, University Heart Center Freiburg - Bad Krozingen, University Hospital Freiburg, Faculty of medicine, 79106 Freiburg, Germany
| | - Christopher L Schlett
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Jakob Neubauer
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ilias Tsiflikas
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Maximilian Frederik Russe
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Philipp Arnold
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Sebastian Faby
- Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany
| | - Matthias F Froelich
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Jakob Weiß
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Stein
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Daniel Overhoff
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Malte Bongers
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Stefan O Schönberg
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Marius Horger
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
13
|
Flohr T, Schmidt B, Ulzheimer S, Alkadhi H. Cardiac imaging with photon counting CT. Br J Radiol 2023; 96:20230407. [PMID: 37750856 PMCID: PMC10646663 DOI: 10.1259/bjr.20230407] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 08/17/2023] [Accepted: 08/24/2023] [Indexed: 09/27/2023] Open
Abstract
CT of the heart, in particular ECG-controlled coronary CT angiography (cCTA), has become clinical routine due to rapid technical progress with ever new generations of CT equipment. Recently, CT scanners with photon-counting detectors (PCD) have been introduced which have the potential to address some of the remaining challenges for cardiac CT, such as limited spatial resolution and lack of high-quality spectral data. In this review article, we briefly discuss the technical principles of photon-counting detector CT, and we give an overview on how the improved spatial resolution of photon-counting detector CT and the routine availability of spectral data can benefit cardiac applications. We focus on coronary artery calcium scoring, cCTA, and on the evaluation of the myocardium.
Collapse
Affiliation(s)
- Thomas Flohr
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Bernhard Schmidt
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Stefan Ulzheimer
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
14
|
Neubauer J, Wilpert C, Gebler O, Taran FA, Pichotka M, Stein T, Molina-Fuentes MF, Weiss J, Juhasz-Böss I, Bamberg F, Windfuhr-Blum M, Neubauer C. Diagnostic Accuracy of Contrast-Enhanced Thoracic Photon-Counting Computed Tomography for Opportunistic Locoregional Staging of Breast Cancer Compared With Digital Mammography: A Prospective Trial. Invest Radiol 2023:00004424-990000000-00179. [PMID: 38038693 DOI: 10.1097/rli.0000000000001051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
Abstract
OBJECTIVE Accurate locoregional staging is crucial for effective breast cancer treatment. Photon-counting computed tomography (PC-CT) is an emerging technology with high spatial resolution and the ability to depict uptake of contrast agents in tissues, making it a promising tool for breast cancer imaging. The aim of this study was to establish the feasibility of locoregional staging of breast cancer through contrast-enhanced thoracic PC-CT, assess its diagnostic performance, and compare it with that of digital mammography (DM). MATERIALS AND METHODS Patients with newly diagnosed breast cancer, DM, and indication of thoracic CT staging were prospectively enrolled in this clinical cohort study over a period of 6 months. Participants underwent contrast-enhanced thoracic PC-CT and breast magnetic resonance imaging in prone position. After blinding to patient data, 2 radiologists independently rated PC-CT and DM regarding the following 6 characteristics: (1) diameter of the largest mass lesion, (2) infiltration of cutis/pectoral muscle/thoracic wall, (3) number of mass lesions, (4) presence/absence of adjacent ductal carcinoma in situ (DCIS), (5) tumor conspicuity, and (6) diagnostic confidence. Reference standard was generated from consensus reading of magnetic resonance imaging combined with all histopathological/clinical data by an independent adjudication committee applying TNM eighth edition. RESULTS Among 32 enrolled female subjects (mean ± SD age, 59 ± 13.0 years), diagnostic accuracy for T-classification was higher for PC-CT compared with DM (0.94 vs 0.50, P < 0.01). Moreover, the correlation of the number of detected tumor masses with the reference standard was stronger for PC-CT than for DM (0.72 vs 0.50, P < 0.01). We observed that PC-CT significantly (P < 0.04) outperformed DM regarding not only sensitivity (0.83 and 0.25, respectively) but also specificity (0.99 and 0.80, respectively) for adjacent DCIS. The κ values for interreader reliability were higher for PC-CT compared with DM (mean 0.88 vs 0.54, respectively; P = 0.01). CONCLUSIONS Photon-counting computed tomography outperformed DM in T-classification and provided higher diagnostic accuracy for the detection of adjacent DCIS. Therefore, opportunistic locoregional staging of breast cancer in contrast-enhanced thoracic PC-CT is feasible and could overcome limitations of DM with the potential to improve patient management.
Collapse
Affiliation(s)
- Jakob Neubauer
- From the Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany (J.N., C.W., O.G., M.F.M.-F., J.W., F.B., M.W.-B., C.N.); Department of Gynecology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany (F.-A.T., I.J.-B.); and Department of Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany (M.P., T.S.)
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Schwartz FR, Alkadhi H. Photon-counting detector CT for abdominal imaging: opportunities and challenges. Eur Radiol 2023; 33:7805-7806. [PMID: 37178196 DOI: 10.1007/s00330-023-09722-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 04/21/2023] [Accepted: 04/26/2023] [Indexed: 05/15/2023]
Affiliation(s)
- Fides Regina Schwartz
- Department of Radiology, Duke University Hospital, Duke University School of Medicine, Durham, NC, USA
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
| |
Collapse
|