1
|
Mortazavi SMJ, Tabatabaei Irani P, Poursalehian M, Mahanrad M, Mirghaderi P, Razzaghof M, Saberi S. Mid-Term to Long-Term Outcomes of Total Hip Arthroplasty Using a Cementless Trochanteric Sparing Short Stem Through Direct Anterior Approach: A Single-Center Study. Arthroplast Today 2025; 32:101623. [PMID: 40008012 PMCID: PMC11850151 DOI: 10.1016/j.artd.2025.101623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 12/13/2024] [Accepted: 01/05/2025] [Indexed: 02/27/2025] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) is increasingly performed in younger patients, necessitating long-term femoral bone preservation. Metaphyseal engaging short stems offer potential benefits by reducing stress shielding and preserving bone stock. However, lacking long-term data in large quantities and younger patients in the literature led this study to assess mid-term to long-term outcome of these short stems. METHODS This retrospective study evaluated the long-term outcomes of 755 hips (667 patients) underwent THA using the Fitmore stem via a direct anterior approach. Clinical and radiographic assessments were conducted, and survival rates were determined using Kaplan-Meier analyses. Statistical analyses were performed to identify associations and predictors of stem revision. RESULTS The overall survival rate for the Fitmore stem was 92.11% at an average follow-up of 10 years. No revisions were performed due to aseptic loosening of the femoral component. Stem revisions were performed in 20 hips, primarily due to periprosthetic fractures followed by periprosthetic joint infections and recurrent dislocations. The clinical outcomes showed significant improvements in HHS, WOMAC Index, and VAS pain scores. Radiographic analysis revealed acceptable rates of complications, with minimal stem subsidence, no severe bone loss, and a low incidence of radiolucent lines and cortical hypertrophy. CONCLUSIONS The Fitmore stem demonstrated favorable mid-term to long-term outcomes in terms of implant survival, functional scores, and radiographic assessments even in younger populations. The findings contribute to the existing body of knowledge on the Fitmore stem's efficacy and safety in preserving bone and achieving satisfactory clinical outcomes in THA. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Seyed Mohammad Javad Mortazavi
- Corresponding author. Professor of Orthopaedic Surgery, Hip and Knee Surgeon, Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Iran. Tel.: 21-6658-1586.
| | | | | | - Mahsa Mahanrad
- Joint Reconstruction Research Center, Orthopedic Surgery Department, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Peyman Mirghaderi
- Joint Reconstruction Research Center, Orthopedic Surgery Department, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammadreza Razzaghof
- Joint Reconstruction Research Center, Orthopedic Surgery Department, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Sadegh Saberi
- Joint Reconstruction Research Center, Orthopedic Surgery Department, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Alesi D, Zinno R, Scoppolini Massini M, Barone G, Valente D, Pinelli E, Zaffagnini S, Mirulla AI, Bragonzoni L. Variations in bone mineral density after joint replacement: A systematic review examining different anatomical regions, fixation techniques and implant design. J Exp Orthop 2025; 12:e70187. [PMID: 40401156 PMCID: PMC12092379 DOI: 10.1002/jeo2.70187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 12/09/2024] [Accepted: 12/11/2024] [Indexed: 05/28/2025] Open
Abstract
Purpose This study aims to evaluate postoperative periprosthetic bone mineral density (BMD) at various time points following joint replacement with different implant designs and fixation techniques. Methods Database search was conducted on MEDLINE, Scopus, Cochrane Central Register of Controlled Trials, Web of Science, and CINAHL for studies analyzing bone remodelling after joint replacement (March 2002-January 2024). Inclusion criteria: English-language articles; total joint replacement; at least two BMD evaluations; observational studies, cross-sectional, prospective, retrospective, randomised controlled trials, and clinical trials. Exclusion criteria: no BMD measurement within one month after surgery; BMD data only expressed as percentage changes or graphs without numerical values; no Gruen zone evaluation for hip replacement; no periprosthetic bone evaluation for knee replacement; pharmacological treatment or comorbidities affecting BMD; revision joint replacements; irrelevant articles; no full text or no original data. Results Sixty-eight articles matched the selection criteria. Fifty-five focused on the hip joint, 12 on the knee, and one on the shoulder. After total hip arthroplasty, the greatest bone resorption occurred in the proximal femur, peaking at 6 months. Cemented implants and tapered stems showed greater bone resorption than cementless implants and anatomical stems. BMD around the acetabular component decreased during the first 6 months but increased in regions subjected to higher loads. In total knee arthroplasty, bone loss occurred in the anterior distal femur and medial tibial plateau, with cemented and posterior-stabilised implants showing greater bone loss than cementless and cruciate-retaining designs. Conclusions The periprosthetic BMD decreases progressively after joint replacement. The fixation technique and implant design influence the extent and pattern of this decline. These factors must be considered during the surgical planning, as they can have long-term implications for bone health and implant longevity. Further research is needed to optimise implant design and surgical techniques to mitigate BMD loss and improve patient outcomes. Level of Evidence Level IV.
Collapse
Affiliation(s)
- Domenico Alesi
- Department of Biomedical and Neuromotor Sciences (DIBINEM)University of BolognaBolognaItaly
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico RizzoliBolognaItaly
| | - Raffaele Zinno
- Department for Life Quality Studies (QUVI)University of BolognaRiminiItaly
| | | | - Giuseppe Barone
- Department for Life Quality Studies (QUVI)University of BolognaRiminiItaly
| | - Davide Valente
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico RizzoliBolognaItaly
| | - Erika Pinelli
- Department for Life Quality Studies (QUVI)University of BolognaRiminiItaly
| | - Stefano Zaffagnini
- Department of Biomedical and Neuromotor Sciences (DIBINEM)University of BolognaBolognaItaly
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico RizzoliBolognaItaly
| | | | - Laura Bragonzoni
- Department for Life Quality Studies (QUVI)University of BolognaRiminiItaly
| |
Collapse
|
3
|
Evola FR, Caldaria A, Costarella L, D'Amico AG, D'Agata V, Vecchio M, Sessa G. Comparative study of fitmore and CLS stems in total hip arthroplasty: midterm clinical and radiographic outcomes. Musculoskelet Surg 2025:10.1007/s12306-025-00885-x. [PMID: 39920536 DOI: 10.1007/s12306-025-00885-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Accepted: 01/13/2025] [Indexed: 02/09/2025]
Abstract
PURPOSE Short-stem implants offer several advantages, including the preservation of bone stock and a physiological load transfer in the subtrochanteric area. The aim of this study was to compare the radiological and functional outcomes of short stem and traditional stem during midterm follow-up. MATERIALS AND METHODS We conducted a retrospective analysis of a consecutive series of 50 patients with Fitmore and CLS stems. Clinical assessment was performed by Harris hip score; additionally, thigh pain was assessed at six months, one year, and the latest follow-up. The following radiological parameters were evaluated: stem alignment, presence of radiolucent lines and osteolysis around the stem, stem subsidence, cortical hypertrophy, femoral stress-shielding, pedestal formation at the tip of the stem, calcar resorption, heterotopic ossification, and implant loosening. RESULTS The mean follow-up duration was 8.4 ± 2.1 years in the CLS group and 7.6 ± 2.2 years in the Fitmore group. The mean HHS improved from 43.0 ± 3.3 to 93.2 ± 2.5 for the CLS group and from 43.2 ± 4.4 to 93.6 ± 3.2 for the Fitmore group, without any statistical differences between the two groups. Thigh pain disappeared in all patients in the Fitmore group, while it persisted in 8% of the patients in the CLS group. There was a significant difference in the level of cortical hypertrophy between the two groups, with 28% in the Fitmore group compared to 12% in the CLS group. No statistically significant difference was observed for other radiological parameters. CONCLUSIONS Both short stems and standard stems demonstrated stable fixation and satisfactory clinical and radiological outcomes.
Collapse
Affiliation(s)
- F R Evola
- Department of Orthopaedic and Trauma Surgery, Cannizzaro Hospital, 95100, Catania, Italy.
- University of Catania, 95100, Catania, Italy.
| | - A Caldaria
- Department of Orthopaedic and Trauma Surgery, San Pietro Fatebenefratelli Hospital, 00189, Rome, Italy
- Faculty of Medicine and Surgery, UniCamillus-Saint Camillus International University of Health and Medical Sciences, 00131, Rome, Italy
| | - L Costarella
- Department of Orthopaedic Surgery, Policlinico Hospital, 95100, Catania, Italy
| | - A G D'Amico
- Department of Drug and Health Sciences, University of Catania, 95125, Catania, Italy
| | - V D'Agata
- Department of Biomedical and Biotechnological Sciences, Section of Anatomy, Histology and Movement Sciences, University of Catania, 95100, Catania, Italy
| | - M Vecchio
- Department of Biomedical and Biotechnological Sciences, University of Catania, 95124, Catania, Italy
| | - G Sessa
- University of Catania, 95100, Catania, Italy
- Department of Orthopaedic Surgery, Policlinico Hospital, 95100, Catania, Italy
| |
Collapse
|
4
|
Ramesh A, Di Laura A, De Angelis S, Henckel J, Hart A. Bone remodeling after revision total hip arthroplasty for large acetabular defects. J Orthop Res 2024; 42:2784-2795. [PMID: 38992884 DOI: 10.1002/jor.25936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 05/14/2024] [Accepted: 06/11/2024] [Indexed: 07/13/2024]
Abstract
Large acetabular bone defects are challenging in hip revision surgery. Clinical assessment is crucial to evaluate modern technologies in surgical reconstruction. We aimed to better understand the bone remodeling that occurs following acetabular reconstruction. Our objectives were: (1) To characterize changes in the shape of the pelvis by studying sequential computed tomography (CT) scans collected immediately and 1-year postoperatively and (2) to identify which part of the pelvis is most susceptible to remodeling. We used the CT scans taken at two timepoints, of 24 patients with acetabular bone defects classified as Paprosky IIIB, treated with three-dimensional (3D)-printed custom-made acetabular implants. Segmented 3D models of the bony pelvis were co-registered using three different techniques. A global co-registration of the full pelvis was conducted, followed by the co-registration of the innominate bone and then ilium only, on the ipsilateral reconstructed side. The relative movements of the ilium, ischium, and pubis were analyzed from visual inspection and using co-registration metrics (root mean square error and intersection over union). No bone remodeling was found in 14/24 patients (58%). The co-registration of the innominate bone indicated bone remodeling in five cases (21%), while the remaining five cases (21%) presented remodeling in the global co-registration but not the innominate bone co-registration, suggestive of changes occurring at the sacroiliac joint. Changes in the pelvic shape were greatest at the pubis and ischium. Bone remodeling may occur in complex cases of Paprosky type IIIB defects, after acetabular reconstruction (occurrence of 21%, 5/24 cases). Surgeons and engineers should consider this when monitoring implant migration.
Collapse
Affiliation(s)
- Angelika Ramesh
- Department of Mechanical Engineering, University College London, London, UK
| | - Anna Di Laura
- Department of Mechanical Engineering, University College London, London, UK
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Sara De Angelis
- Department of Mechanical Engineering, University College London, London, UK
| | - Johann Henckel
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Alister Hart
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK
- Cleveland Clinic London, London, UK
| |
Collapse
|
5
|
Stadler C, Bolm JS, Schopper C, Schauer B, Holzbauer M, Gotterbarm T, Luger M. Learning curve comparison between switching approach and switching implant in cementless short stem total hip arthroplasty. Arch Orthop Trauma Surg 2024; 144:4259-4265. [PMID: 39249133 PMCID: PMC11564367 DOI: 10.1007/s00402-024-05518-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 08/21/2024] [Indexed: 09/10/2024]
Abstract
INTRODUCTION Implementing new approaches or new implants is always related with a certain learning curve in total hip arthroplasty (THA). Currently, many surgeons are switching to minimally invasive approaches combined with short stems for performing THA. Therefore, we aimed to asses and compare the learning curve of switching from an anterolateral Watson Jones approach (ALA) to a direct anterior approach (DAA) with the learning curve of switching from a neck-resecting to a partially neck-sparing short stem in cementless THA. MATERIALS AND METHODS The first 150 consecutive THA performed through a DAA (Group A) and the first 150 consecutive THA using a partially neck-sparing short stem (Group B) performed by a single surgeon were evaluated within this retrospective cohort study. All cases were screened for surgery related adverse events (AE). Furthermore, the operative time of each surgery was evaluated and the learning curve assessed performing a cumulative sum (CUSUM) analysis. RESULTS Overall, significantly more AE occurred in Group A compared to Group B (18.0% vs. 10.0%; p = 0.046). The sub-analysis of the AE revealed higher rates of periprosthetic joint infections (2.7% vs. 0.7%; p = 0.176), periprosthetic fractures (4.0% vs. 2.0%; p = 0.310) and overall revisions (4.7% vs. 1.3% p = 0.091) within Group A without statistical significance. The CUSUM analysis revealed a consistent reduction of operative time after 97 cases in Group A and 79 cases in Group B. CONCLUSION A significantly higher overall rate of AE was detected while switching approach compared to switching implant for performing THA. However, according to the results of this study, surgeons should be aware of the learning curve of the adoption to a new implant with different fixation philosophy as well.
Collapse
Affiliation(s)
- Christian Stadler
- Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria.
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria.
| | | | - Clemens Schopper
- Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria
| | - Bernhard Schauer
- Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria
| | - Matthias Holzbauer
- Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria
| | - Tobias Gotterbarm
- Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria
| | - Matthias Luger
- Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria
| |
Collapse
|
6
|
Freitag T, Fuchs M, Friedrich D, Bieger R, Reichel H, Oltmanns M. The Migration Pattern of a Short-Tapered Femoral Stem Correlates with the Occurrence of Cortical Hypertrophies: A 10-Year Longitudinal Study Using Ein Bild Röntgen Analyse-Femoral Component Analysis. J Clin Med 2024; 13:3616. [PMID: 38930145 PMCID: PMC11205188 DOI: 10.3390/jcm13123616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 06/14/2024] [Accepted: 06/17/2024] [Indexed: 06/28/2024] Open
Abstract
Background: Shorter hip stems have shown promising mid-term results but lack long-term data. High rates of distal cortical hypertrophy (CH) have been described, suggesting a more diaphyseal load transmission. This study aimed to determine patient-specific and surgery-related factors influencing CH and their impact on 10-year outcomes. Methods: It included 100 consecutive total hip arthroplasties (THAs) using the Fitmore stem (Zimmer, Warsaw, Indiana), with clinical and radiographic follow-ups at 1, 2, 5, and at least 10 years post-surgery. Results: No revisions were performed due to aseptic loosening after a mean of 11.6 years (range: 10-13.5 years). CH was observed in 26% of hips, primarily in Gruen zones 3 and 5. There was no significant difference in the Harris Hip Score between patients with and without CH. Larger stem sizes and greater axial subsidence significantly correlated with CH occurrence (OD 1.80, (1.13-1.92), p = 0.004; OD 1.47, (1.04-2.08), p = 0.028). The Fitmore stem demonstrated excellent survival rates and favorable outcomes over 10 years. Conclusions: Despite a lower CH rate compared to other studies, significant correlations with stem size and subsidence were identified. This study underscores the importance of patient selection and achieving high primary stability to maintain the metaphyseal anchoring concept.
Collapse
Affiliation(s)
- Tobias Freitag
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany; (M.F.); (D.F.); (H.R.); (M.O.)
| | - Michael Fuchs
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany; (M.F.); (D.F.); (H.R.); (M.O.)
| | - David Friedrich
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany; (M.F.); (D.F.); (H.R.); (M.O.)
| | - Ralf Bieger
- Center for Knee, Hip and Shoulder Surgery, Schoen Clinic München Harlaching, Harlachinger Strasse 51, 81547 Munich, Germany;
| | - Heiko Reichel
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany; (M.F.); (D.F.); (H.R.); (M.O.)
| | - Moritz Oltmanns
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany; (M.F.); (D.F.); (H.R.); (M.O.)
| |
Collapse
|
7
|
Christiansen JD, Laursen M, Blunn GW, Nielsen PT. Stable fixation of an ultra-short femoral neck-preserving hip prosthesis: a 5-year RSA, DXA, and clinical prospective outcome study of 48 patients. Acta Orthop 2024; 95:138-146. [PMID: 38392247 PMCID: PMC10886218 DOI: 10.2340/17453674.2024.40074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 01/09/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND AND PURPOSE We previously showed promising primary stability and preservation of bone stock with the ultra-short neck-loading hip implant in total hip arthroplasty (THA). The aim of this study was to evaluate clinical outcome, implant stability, and bone mineral density (BMD). METHODS 50 patients were treated with the ultra-short neck Primoris hip implant at baseline and 48 were available for evaluation at 5-year follow-up. 5 different patient-reported outcome measures (PROMs) including hip-specific scores, disease-specific and generic quality of life outcome measures, and an activity score were used. Furthermore, implant stability using radiostereometric analysis (RSA) and assessment of periprosthetic BMD using dual-energy X-ray absorptiometry (DXA) were applied. RESULTS By 1-year follow-up, all PROMs showed improvements and remained high at 5-year follow-up. After initial distal translation (subsidence) and negative rotation around the z-axis (varus tilt) the implant showed stable fixation at 5-year follow-up with no further migration beyond 12 months. In the regions of interest (ROI) 3 and 4, BMD remained stable. In ROI 2, further bone loss of 12% was found at 5-year follow-up. CONCLUSION Clinical outcome including PROMs was satisfying throughout the 5-year follow-up period. The hip implant remains stable with both bone preservation and loss 5 years after surgery.
Collapse
Affiliation(s)
- Janus D Christiansen
- Department of Orthopaedic Surgery and Orthopaedic Surgery Research Unit, Aalborg University, Aalborg, North Region; Department of Clinical Medicine, Aalborg University, Aalborg, North Region, Denmark.
| | - Mogens Laursen
- Department of Orthopaedic Surgery and Orthopaedic Surgery Research Unit, Aalborg University, Aalborg, North Region; Department of Clinical Medicine, Aalborg University, Aalborg, North Region, Denmark
| | - Gordon W Blunn
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK
| | - Poul T Nielsen
- Department of Orthopaedic Surgery and Orthopaedic Surgery Research Unit, Aalborg University, Aalborg, North Region
| |
Collapse
|
8
|
Diaz-Dilernia F, Lucero C, Slullitel PA, Zanotti G, Comba F, Piccaluga F, Buttaro M. Medium-term outcomes of conventional versus short uncemented femoral stems for primary total hip arthroplasty in patients younger than 55 years. Hip Int 2024; 34:82-91. [PMID: 37293776 DOI: 10.1177/11207000231177588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
BACKGROUND Short stems are designed with a bone preservation philosophy in mind. This study aims to compare the outcomes/complications and survival of a collarless fully hydroxyapatite (HA)-coated conventional tapered stem and a HA-coated partial neck-retaining uncemented short stem in patients ⩽55 years old at medium-term follow-up. METHODS We retrospectively studied 247 uncemented THAs operated between 2010 and 2014, comparing 146 patients treated with the fully HA-coated collarless stem (Group A) with 101 patients treated with a partial neck preserving, HA-coated short stem (Group B). 87 and 62 males were in groups A and B, respectively (p = 0.11). The mean age of the series was 46 years (17-55) (p =0.16). The mean follow-up of groups A and B were 9.9 (7-12) years and 9.7 (7-12) years, respectively (p =0.21). RESULTS Mean Harris Hip Score improved from 55 to 92 in group A (p <0.001) and from 54 to 95 in group B (p <0.001), without differences between groups. Mean femoral neck length preservation in groups A and B was 13.6 (0-28) mm and 26 (11-38) mm, respectively (p =0.001). 13 (8.9%) and 1 (1%) patients in groups A and B presented postoperative complications, respectively (p =0.008). The conventional stem group had more aseptic loosening (Group A 3.4% vs. Group B 0%, p =0.06) along with more Symptomatic radiolucent lines (Group A 3.4% vs. Group B 0%, p =0.06). CONCLUSIONS Both conventional and short stems showed excellent implant survival rates and functional outcomes at a mean follow-up of 9.8 years. However, complications and radiolucent lines were more frequent with a collarless conventional-length stem. Bone preservation of the femoral neck and diaphysis may be preferred in active young patients.
Collapse
Affiliation(s)
- Fernando Diaz-Dilernia
- Sunnybrook Health Sciences Centre/Holland Orthopaedic & Arthritic Centre, Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, University of Toronto, ON, Canada
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Carlos Lucero
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Pablo A Slullitel
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Gerardo Zanotti
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Fernando Comba
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Francisco Piccaluga
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Martin Buttaro
- Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| |
Collapse
|
9
|
Anjiki K, Hayashi S, Fujishiro T, Hiranaka T, Kuroda R, Matsumoto T. Rectangular tapered short stem excellently preserves proximal bone mineral density preservation than tapered wedge short stem. Acta Orthop Belg 2023; 89:491-497. [PMID: 37935234 DOI: 10.52628/89.3.11833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Fitmore stem is a rectangular, tapered, short, cementless stem. A characteristic feature of this stem is that it provides rotational stability due to the high medullary occupancy achieved by its rectangular cross-section and thick antero- posterior width. We aimed to investigate the differences in periprosthetic bone remodelling between a rectangular- tapered short stem and a short tapered-wedge stem. Eighty patients who underwent primary total hip arthroplasty using a rectangular-tapered short stem (Fitmore) or a short tapered-wedge stem (Tri-Lock BPS) were enrolled in this study. Bone mineral densities (BMDs) in the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry at baseline, and at 6 and 24 months postoperatively. Peri-prosthetic BMD and clinical factors were assessed and compared. In addition, correlations between periprosthetic BMD changes and stem anteversion error were analyzed using Pearson's correlation coefficient in the two groups. A significantly better postoperative periprosthetic BMD change was found in zones 1 and 7 in the rectangular-tapered group. Additionally, no significant correlation was observed between stem anteversion error and periprosthetic BMD changes in the rectangular-tapered groups. However, in the tapered-wedge group, there were significant negative correlations between the stem anteversion error and BMD changes at 6 months and 24 months in zones 1 and 7. In the rectangular-tapered group, a significantly better postoperative periprosthetic BMD change was found particularly in the region proximal to the stem. Rectangular-tapered short stem can be more resistant to rotation due to higher medullary occupancy and may lead to better periprosthetic BMD than the tapered-wedge short stem, especially in the proximal region of the stem.
Collapse
|
10
|
Burchard R, Graw JA, Soost C, Schmitt J. Stress shielding effect after total hip arthroplasty varies between combinations of stem design and stiffness-a comparing biomechanical finite element analysis. INTERNATIONAL ORTHOPAEDICS 2023:10.1007/s00264-023-05825-7. [PMID: 37269400 PMCID: PMC10345085 DOI: 10.1007/s00264-023-05825-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 04/22/2023] [Indexed: 06/05/2023]
Abstract
PURPOSE Total hip arthroplasty (THA) has become a highly frequent orthopaedic procedure. Multiple approaches have been made to design the femoral component for THA with a mechanical behaviour as close as possible to a natural femur. The aim of this study was to compare different combinations of design and biomechanical properties of THA prostheses and their impact on stress shielding of the periprosthetic bone. METHODS Virtual implantation of different stem designs (straight standard stem, straight short stem, anatomical short stem) by finite element analysis based on in vivo data from computer tomography was performed. For each stem, three grades of stiffness were generated, followed by a strain analysis. RESULTS Reduction of stem stiffness led to less stress shielding. Implantation of an anatomical short-stem prosthesis with low stiffness provided the most physiological strain-loading effect (p < 0.001). CONCLUSION A combination of a short and an anatomically designed stem with a low stiffness might provide a more physiological strain transfer during THA. Biomechanical properties of the femoral component for THA should be considered as a multifactorial function of dimensions, design, and stiffness.
Collapse
Affiliation(s)
- Rene Burchard
- University of Marburg, Marburg, Germany.
- Department of Orthopedics and Trauma Surgery, University of Giessen and Marburg, Marburg, Germany.
- Department of Orthopedics and Trauma Surgery, Lahn-Dill-Kliniken, Rotebergstr. 2, 35683, Dillenburg, Germany.
| | - Jan A Graw
- Department of Anesthesiology and Intensive Care Medicine, Ulm University Hospital, Ulm, Germany
| | | | - Jan Schmitt
- University of Marburg, Marburg, Germany
- Department of Orthopedics and Trauma Surgery, University of Giessen and Marburg, Marburg, Germany
- Department of Orthopedics and Trauma Surgery, Lahn-Dill-Kliniken, Rotebergstr. 2, 35683, Dillenburg, Germany
| |
Collapse
|
11
|
Rilby K, Mohaddes M, Kärrholm J. Similar results after five years with the use of the Fitmore or the CLS femoral components. Bone Jt Open 2023; 4:306-314. [PMID: 37130583 PMCID: PMC10154086 DOI: 10.1302/2633-1462.45.bjo-2023-0007.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/04/2023] Open
Abstract
Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years. At two and five years, more patients considered the hip with the CLS femoral component as superior but without a statistically significant difference. There were no differences in clinical outcome, magnitude of femoral component migration, or change of bone mineral density at five years. At three months, the Fitmore femoral component had subsided a median -0.71 mm (interquartile range (IQR) -1.67 to -0.20) and the CLS femoral component -0.70 mm (IQR -1.53 to -0.17; p = 0.742). In both groups the femoral head centre had migrated posteriorly (Fitmore -0.17 mm (IQR -0.98 to -0.04) and CLS -0.23 mm (IQR -0.87 to 0.07; p = 0.936)). After three months neither of the femoral components showed much further migration. During the first postoperative year, one Fitmore femoral component was revised due to aseptic loosening. Up to five years, we found no statistically significant difference in outcomes between the Fitmore and the CLS femoral components. The slightly worse outcomes, including one revised hip because of loosening, speaks against the hypothesis that the Fitmore femoral component should be advantageous compared to the CLS if more patients had been recruited to this study.
Collapse
Affiliation(s)
- Karin Rilby
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Mölndal, Sweden
- Department of Orthopaedic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maziar Mohaddes
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Mölndal, Sweden
- Department of Orthopaedic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Mölndal, Sweden
- Department of Orthopaedic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
12
|
Al-Hajaj Z, Avval PT, Bougherara H. Computational prediction of the long-term behavior of the femoral density after THR using the Silent Hip stem. Comput Methods Biomech Biomed Engin 2023; 26:373-382. [PMID: 35436164 DOI: 10.1080/10255842.2022.2064712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Aseptic loosening due to the progressive periprosthetic bone resorption following total hip replacement is a crucial concern, that causes complications and failure of the arthroplasty surgery. The mismatch in stiffness between the hip implant and the surrounding femoral bone is one of the key factors leading to bone density resorption. This paper aimed to investigate the long-term response of the femoral bone after THR using the Silent Hip stem. For this purpose, a validated thermodynamic-based computational model was used to compute the change in bone density before and after THR. This model incorporated essential factors involved in bone remodeling process, such as mechanical loading, and biochemical affinities. The results of the numerical simulations using 3D finite element analysis were analyzed in five zones of interest qualitatively and quantitatively. Bone density predictions showed notable bone resorption in cervical areas, specifically in zone 1 and zone 5 of -18.7% and -14%, respectively. Conversely, bone formation was observed in the greater trochanter area (zone 2) of +25%. Stress shielding seemed to occur at cervical area due to the reduction in the mechanical loading in this region. Based on the quantitative analysis of the bone density distribution throughout the femoral bone, it appears that the Silent Hip stem achieved less bone resorption compared to conventional hip stem designs reported in the literature, which could be used for active patients.
Collapse
Affiliation(s)
- Zainab Al-Hajaj
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada.,Department of Mechanical Engineering, Australian College of Kuwait, Safat, Kuwait
| | - Pouria Tavakkoli Avval
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada.,Wearable, Interactive, and Mobile Technologies Access Centre in Health, Centennial College, Toronto, ON, Canada
| | - Habiba Bougherara
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada
| |
Collapse
|
13
|
Li Z, Li M, Yao X, Liu B, Liu S, Liu Z, Zhang B, Han Y. Bone Remodelling of the Proximal Femur After Hip Revision with a Metaphyseal-Fixation Femoral Stem Component. Ther Clin Risk Manag 2023; 19:171-181. [PMID: 36820321 PMCID: PMC9938707 DOI: 10.2147/tcrm.s393876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Accepted: 02/09/2023] [Indexed: 02/16/2023] Open
Abstract
Background Whether hip revision with a metaphyseal-fixation femoral stem component can restore the bone mass of the proximal femur remains unclear. The aims of this study were to identify whether the bone mineral density (BMD) of the proximal femur increases following hip revision with a metaphyseal-fixation femoral stem and to identify the factors associated with BMD recovery. Methods This was a retrospective study involving 36 patients who underwent hip arthroplasty with a metaphyseal-diaphyseal fixation stem (standard length stem) and had indications for hip revision, which was performed with a proximal press-fit short-stem prosthesis for each patient. Dual-energy X-ray absorptiometry (DEXA) was used to obtain, evaluate, and compare the BMD at baseline and one year and two years postoperatively. The proximal femur was divided into several independent areas according to the Gruen zone (Gruen 1 to Gruen 7 from the greater trochanter counterclockwise to the lesser trochanter). Logistic regression analyses were used to assess potential factors significantly associated with an increase in BMD. Results An increased BMD was obviously identified in the proximal femur. Two years after the surgery, the BMD of the Gruen 1, Gruen 2, Gruen 6, and Gruen 7 areas had increased by 22.6%, 12.6%, 16.2% and 24.2%, respectively, relative to baseline. Three independent risk factors associated with bone mineral density recovery were identified: age (OR=1.100, 95% CI=1.005-1.203, P=0.038), osteoporosis (OR=14.921, 95% CI=1.223-182.101, P=0.034) and fair to poor hip function (OR=13.142, 95% CI=1.024-168.582, P=0.048). Conclusion This study confirms that metaphyseal-fixation stem hip revision can indeed help restore bone mass in the proximal femur, especially in the Gruen 1, Gruen 2, Gruen 6 and Gruen 7 zones. It was also found that advanced age, osteoporosis, and fair to poor hip joint function were three important risk factors affecting the recovery of proximal femur bone mass after surgery. Trial Registration Retrospectively registered.
Collapse
Affiliation(s)
- Zhijie Li
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China,Orthopedics Department, Affiliated Hospital of Hebei Engineering University, Handan, People’s Republic of China
| | - Mengnan Li
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China
| | - Xiaowei Yao
- Orthopedics Department, Hebei Provincial Chest Hospital, Shijiazhuang, People’s Republic of China
| | - Bo Liu
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China
| | - Sikai Liu
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China
| | - Zeming Liu
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China
| | - Binquan Zhang
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China
| | - Yongtai Han
- Department of Osteonecrosis and Hip Surgery, Hebei Medical University Third Affiliated Hospital, Shijiazhuang, People’s Republic of China,Correspondence: Yongtai Han, Email
| |
Collapse
|
14
|
Anil U, Singh V, Schwarzkopf R. Diagnosis and Detection of Subtle Aseptic Loosening in Total Hip Arthroplasty. J Arthroplasty 2022; 37:1494-1500. [PMID: 35189292 DOI: 10.1016/j.arth.2022.02.060] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/10/2022] [Accepted: 02/14/2022] [Indexed: 02/02/2023] Open
Abstract
Aseptic loosening is a common cause of revision total hip arthroplasty (rTHA), and with the rising number of primary THAs, revisions for aseptic loosening represent a significant burden for arthroplasty surgeons. Aseptic loosening remains a diagnostic and management challenge. Loosening can occur as a result of inadequate initial fixation, mechanical loss of fixation over time, or a biological loss of fixation over time. However, in most cases, etiology is multifactorial, involving all 3 factors. The diagnosis of aseptic loosening involves a careful history, focused clinical exam, and thorough evaluation of imaging using several diagnostic modalities. The careful evaluation of serial radiographs remains the cornerstone of diagnosis with additional input from advanced imaging modalities such as FDG-PET, DEXA, MRI, and several others, each offering unique advantages and disadvantages. In certain patients, history and physical exam might be the only initial obvious signs of loosening, and thus, unexplained continuous pain augmented by imaging findings serves as an indication for revision surgery.
Collapse
Affiliation(s)
- Utkarsh Anil
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| | - Vivek Singh
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| |
Collapse
|
15
|
Huang CC, Cheng CK, Wei HW. A Time-Dependent Design Concept of a Cementless Hip Stem Prosthesis for Improving Physiological Load Transfer in Proximal Femur: A Finite Element Analysis. J Med Biol Eng 2022. [DOI: 10.1007/s40846-022-00728-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Hakim R, Weinstein A, Dabby D, Rozen N, Shabshin N, Rubin G. Successful reconstruction of natural femoral anteversion using a short femoral stem in total hip arthroplasty surgery. J Int Med Res 2022; 50:3000605221091500. [PMID: 35443831 PMCID: PMC9047853 DOI: 10.1177/03000605221091500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Objective Total hip arthroplasty (THA) involves postoperative risks, such as thigh
pain, periprosthetic fractures, and stress yielding. Short, anatomical,
metaphyseal-fitting, cementless femoral stems were developed to reduce these
postoperative risks. This study aimed to examine the “MiniMAX” prosthesis,
which is a new generation, short, anatomical femoral stem made by
Medacta. Methods Patients underwent a low-dose computed tomography scan. Femoral anteversion
was measured. We assessed the position and anteversion of the femoral
component and compared them with the unoperated side. We also assessed the
patients’ satisfaction and functional levels at 6 months postsurgery using
the Harris Hip Score (HHS) and the Oxford Hip Score (OHS). Results Nineteen individuals were recruited in this study. We found no significant
difference in femoral anteversion between the operated hip and the native
hip. Using the HHS and OHS questionnaires, we found clinical improvement in
the 6-month postoperative scores compared with the preoperative scores. Discussion The new-generation, short, anatomical femoral stem made by Medacta is
successful in reproducing natural femoral anteversion, while also improving
patients’ functioning and lifestyle. Future large-scale, prospective
comparison trials are required to further investigate this topic.
Collapse
Affiliation(s)
- Raja Hakim
- Orthopedic Department, Emek Medical Center, Afula, Israel
| | | | - Dan Dabby
- Orthopedic Department, Emek Medical Center, Afula, Israel
| | - Nimrod Rozen
- Orthopedic Department, Emek Medical Center, Afula, Israel.,Faculty of Medicine, Technion, Haifa, Israel
| | - Nogah Shabshin
- Orthopedic Department, Emek Medical Center, Afula, Israel.,Penn Medicine, Philadelphia, PA, USA
| | - Guy Rubin
- Orthopedic Department, Emek Medical Center, Afula, Israel.,Faculty of Medicine, Technion, Haifa, Israel
| |
Collapse
|
17
|
Yoo JI, Cha Y, Lee YK, Ha YC, Koo KH. Do Cementless Short Tapered Stems Reduce the Incidence of Thigh Pain After Hip Arthroplasty? Systematic Review and Meta-Analysis. J Korean Med Sci 2022; 37:e41. [PMID: 35166078 PMCID: PMC8845099 DOI: 10.3346/jkms.2022.37.e41] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 12/21/2021] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND The purpose of this study was to determine whether short tapered stems reduce the rate of thigh pain through a systematic review and meta-analysis of comparative studies between short tapered stems and standard-length tapered stems. METHODS We conducted a meta-analysis of comparative studies: 1) retrospective studies and 2) randomized controlled trials (RCTs), on 2 stem designs: short tapered stem versus standard-length tapered stem. Studies were selected by means of the following criteria: 1) study design: retrospective comparative studies, prospective comparative studies, RCTs; 2) study population: patients with total hip arthroplasty or hemiarthroplasty for hip disease or hip fracture; 3) intervention: short tapered stem and standard tapered stem; and 4) outcomes; thigh pain, other clinical results. RESULTS Among the 250 articles that were identified at the initial search, 6 studies, 4 RCTs and 2 retrospective comparative studies, were included in this meta-analysis. In the analysis of retrospective studies, the short tapered stem reduced the risk of thigh pain compared to the standard tapered stem (risk ratio [RR] = 0.13; 95% confidence interval [CI], 0.02-0.09; Z = -2.07; P = 0.039). However, in the analysis of RCTs, the incidence of thigh pain was similar between the two stem designs (RR = 1.21; 95% CI, 0.76-1.93; Z = 0.82; P = 0.410). Overall meta-analysis including all studies showed that the short tapered stem did not reduce the incidence of thigh pain compared to the standard-length tapered stem (RR = 0.91; 95% CI, 0.59-1.40; Z = -0.44, P = 0.663). CONCLUSIONS We did not find a significant difference in the incidence of thigh pain between short tapered stem and standard tapered stem in hip arthroplasty. TRIAL REGISTRATION PROSPERO Identifier: CRD42021231240.
Collapse
Affiliation(s)
- Jun-Il Yoo
- Department of Orthopaedic Surgery, Gyeongsang National University Hospital, Jinju, Korea
| | - Yonghan Cha
- Department of Orthopedic Surgery, Daejeon Eulji Medical Center, Eulji University School of Medicine, Daejeon, Korea.
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Korea
| |
Collapse
|
18
|
Djebara AE, El Yagoubi A, Mertl P, El Fatayri B, Dehl M, Gabrion A. Comparison of periprosthetic bone mineral density between two types of short-stems in total hip arthroplasty with a mean follow-up of 4 years. Orthop Traumatol Surg Res 2022; 108:103044. [PMID: 34389498 DOI: 10.1016/j.otsr.2021.103044] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 12/17/2020] [Accepted: 01/04/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The use of short stems in primary hip arthroplasty has grown considerably in recent years, with a large variety of designs and stabilization methods available. Few studies have directly compared how these designs and fixation modes influence the bone mineral density (BMD) that is said to be better preserved with shorter implants. This led us to carry out a medium-term retrospective comparative study to (1) specify how the design of two different types of short stems influences the periprosthetic BMD, (2) compare the radiological and clinical outcomes of these stems. HYPOTHESIS The periprosthetic BMD of a short stem varies based on the implant's design. MATERIALS AND METHODS Ninety-three patients underwent total hip arthroplasty (THA) with a short stem between July 2012 and July 2014. Two groups of patients were formed: Vitae™ short stem (Adler Ortho, Milan, France), Optimys™ short stem (Mathys, Bettlach, Switzerland). The Vitae group consisted of 46 patients, while the Optimys group consisted of 47 patients. The mean age was 66 years, and the mean body mass index (BMI) was 26 kg/m2. The groups had comparable age, BMI, sex, Harris Hip score and preoperative radiological features. Periprosthetic BMD of the two types of implants was determined between the 1st and 4th year postoperative using dual-energy x-ray absorptiometry (DEXA) in the Gruen zones. The radiological and clinical outcomes were also determined. RESULTS There was a significant decrease in BMD in zone 7(-5.8%±0.1 CI95%[-0.09; -0.02] (p=0.003)), zone 2 (-4.8% ±0.1 CI95%[-0.093; -0.003] (p=0.038)) and zone 6 (-11% ±0.2 CI95%[-0.19; -0.03] (p=0.009)) in the patients with Vitae stems and in zone 2 (-13.7%±0.3 CI95%[-0.25; -0.03] (p=0.018)) in the patients with Optimys stems. A significant difference in BMD in zone 7 at 1 year (p=0.014) and 4 years (p=0.001) postoperative and in zone 6 (p=0.011) at 4 years postoperative existed between groups, with the Optimys group having higher BMD. There was a significant increase in femoral offset in the Optimys group but not the Vitae group: Δoffset=-0.50 mm±5.2 CI95%[-2.05; 1.05] (p=0.522) and Δoffset=2.79 mm±4.2 CI95%[1.21; 4.37] (p=0.001). The Harris Hip score was not significantly different between the two groups at 4 years postoperative (95.3±2.5 [88; 99] vs. 95.2±2.6 [88; 99] (p=0.991)). DISCUSSION The design of short stems appears to influence the distribution of loads and the periprosthetic BMD. These stems are associated with very good radiological and clinical results in the medium term. Bone remodeling appears to continue beyond 1 year after the THA procedure. LEVEL OF EVIDENCE III; Retrospective case-control study.
Collapse
Affiliation(s)
- Az-Eddine Djebara
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France.
| | - Abdelkader El Yagoubi
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Patrice Mertl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Bachar El Fatayri
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Massinissa Dehl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Antoine Gabrion
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| |
Collapse
|
19
|
Fujii H, Hayama T, Abe T, Takahashi M, Amagami A, Matsushita Y, Otani T, Saito M. Do radiological findings around the Fitmore stem change over time? Bone Jt Open 2022; 3:20-28. [PMID: 35005984 PMCID: PMC9047072 DOI: 10.1302/2633-1462.31.bjo-2021-0122.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Aims Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population. Methods This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph. Results CH was observed in 49 hips (21.1%), AT was observed in 63 hips (27.2%), and RLLs were observed in 34 hips (14.7%) at one year postoperatively. Among 34 hips with RLLs, 70.6% showed change of either D or I on the three-year radiograph. BC was observed in younger patients more frequently. Conclusion The Fitmore stem works well in a Japanese population with favourable radiological change on hips with RLLs. Longer-term follow-up is required to determine clinical relevance. Cite this article: Bone Jt Open 2022;3(1):20–28.
Collapse
Affiliation(s)
- Hideki Fujii
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Tetsuo Hayama
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Toshiomi Abe
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Motoi Takahashi
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Ayano Amagami
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Yohei Matsushita
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Takuya Otani
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Mitsuru Saito
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
20
|
Belfrage O, Weber E, Sundberg M, Flivik G. Preserved periprosthetic bone stock at 5 years post-operatively with uncemented short hip stem in both collared and collarless version. Arch Orthop Trauma Surg 2022; 142:3489-3496. [PMID: 34841462 PMCID: PMC9522768 DOI: 10.1007/s00402-021-04225-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 10/13/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Previous bone density studies have generally shown bone resorption around both cemented and uncemented total hip arthroplasty (THA) stems. This is presumed to be due to stress shielding. Short stems have been introduced partly to preserve bone in the proximal femur by a more physiological loading of the bone. The purpose of this study was to evaluate bone remodeling around a short, fully hydroxyapatite-coated titanium stem that comes in a collared and collarless version. PATIENTS AND METHODS A prospective cohort of 50 patients included in a study evaluating the Furlong Evolution stem has been followed for 5 years. Examination was done with dual energy X-ray absorptiometry (DXA) postoperatively, at 1, 2 and 5 years. Clinical outcome was followed with radiography and both general and hip specific outcome measures. RESULTS The two versions of the stem behaved similarly regarding bone remodeling. After an initial decrease up to 1 year, bone mineral density (BMD) increased in all Gruen zones up to 2 years and at 5 years bone stock was still preserved compared with postoperatively (net BMD + 1.2% (95% CI - 0.4 to 2.8)). Increase in BMD occurred mainly in the greater trochanter and distally around the stem with a decrease in the calcar area. Both versions showed excellent clinical outcome up to 5 years. CONCLUSION This short stem seems to preserve proximal bone stock up to 5 years, exhibiting similar behaviour both with and without a collar. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION ClinicalTrials.gov, (identifier: NCT01894854). July 10, 2013.
Collapse
Affiliation(s)
- Ola Belfrage
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| | - Erik Weber
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| | - Martin Sundberg
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
21
|
de Waard S, van der Vis J, Venema PAHT, Sierevelt IN, Kerkhoffs GMMJ, Haverkamp D. Short-term success of proximal bone stock preservation in short hip stems: a systematic review of the literature. EFORT Open Rev 2021; 6:1040-1051. [PMID: 34909223 PMCID: PMC8631238 DOI: 10.1302/2058-5241.6.210030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Total hip arthroplasty is performed more frequently in younger patients nowadays, making long-term bone stock preservation an important topic. A mechanism for late implant failure is periprosthetic bone loss, caused by stress shielding around the hip stem due to different load distribution. Short stems are designed to keep the physical loading in the proximal part of the femur to reduce stress shielding. The aim of this review is to give more insight into how short and anatomic stems behave and whether they succeed in preservation of proximal bone stock. A systematic literature search was performed to find all published studies on bone mineral density in short and anatomic hip stems. Results on periprosthetic femoral bone mineral density, measured with dual-energy X-ray absorptiometry (DEXA), were compiled and analysed per Gruen zone in percentual change. A total of 29 studies were included. In short stems, Gruen 1 showed bone loss of 5% after one year (n = 855) and 5% after two years (n = 266). Gruen 7 showed bone loss of 10% after one year and –11% after two years. In anatomic stems, Gruen 1 showed bone loss of 8% after one year (n = 731) and 11% after two years (n = 227). Gruen 7 showed bone loss of 14% after one year and 15% after two years. Short stems are capable of preserving proximal bone stock and have slightly less proximal bone loss in the first years, compared to anatomic stems.
Cite this article: EFORT Open Rev 2021;6:1040-1051. DOI: 10.1302/2058-5241.6.210030
Collapse
Affiliation(s)
- Sheryl de Waard
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands.,Academic Medical Centre (AMC), Amsterdam, Netherlands
| | - Jacqueline van der Vis
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Pascale A H T Venema
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Inger N Sierevelt
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | | | - Daniël Haverkamp
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| |
Collapse
|
22
|
Freitag T, Bieger R, Kiefer H, Dornacher D, Reichel H, Ignatius A, Dürselen L. Biomechanics of a calcar loading and a shortened tapered femoral stem: Comparative in-vitro testing of primary stability and strain distribution. J Exp Orthop 2021; 8:74. [PMID: 34491456 PMCID: PMC8423873 DOI: 10.1186/s40634-021-00388-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 08/13/2021] [Indexed: 11/29/2022] Open
Abstract
Purpose The most common femoral short stems available on the market can, in principle, be divided with regard to their anchoring concepts into a calcar loading and a shortened tapered design. The purpose of this study was to compare the primary stability and stress-shielding of two short stems, which correspond to these two different anchoring concepts. Methods Using seven paired fresh frozen human cadaver femurs, primary axial and rotational stabilities under dynamic load (100–1600 N) were evaluated by miniature displacement transducers after 100,000 load cycles. Changes in cortical strains were measured before and after implantation of both stem types to detect implant-specific load transmission and possible stress-shielding effects. Results Reversible and irreversible micromotions under dynamic load displayed no significant differences between the two implants. Implantation of either stem types resulted in a reduction of cortical strains in the proximal femur, which was less pronounced for the calcar loading implant. Conclusions Both short stems displayed comparable micromotions far below the critical threshold above which osseointegration may disturbed. Neither short stem could avoid proximal stress-shielding. This effect was less pronounced for the calcar loading short stem, which corresponds to a more physiological load transmission.
Collapse
Affiliation(s)
- Tobias Freitag
- Department of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany.
| | - Ralf Bieger
- Department of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany
| | - Hartmuth Kiefer
- Department of Trauma and Orthopaedic Surgery, Lukas Hospital, Buende, Germany
| | - Daniel Dornacher
- Department of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany
| | - Heiko Reichel
- Department of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany
| | - Anita Ignatius
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre, Ulm University Medical Centre, Helmholtzstr. 14, 89081, Ulm, Germany
| | - Lutz Dürselen
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre, Ulm University Medical Centre, Helmholtzstr. 14, 89081, Ulm, Germany
| |
Collapse
|
23
|
Holm-Glad T, Godang K, Bollerslev J, Røkkum M, Reigstad O. Assessing Periprosthetic Bone in Total Wrist Arthroplasty: The Validity of DXA. J Clin Densitom 2021; 24:433-441. [PMID: 33172804 DOI: 10.1016/j.jocd.2020.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 10/12/2020] [Accepted: 10/13/2020] [Indexed: 01/01/2023]
Abstract
INTRODUCTION Dual-energy X-ray absorptiometry (DXA) can measure bone mineral density (BMD) around joint arthroplasties. DXA has never been used in total wrist arthroplasties (TWA). We investigated (1) whether BMD differs between 2 TWAs implanted in the same cadaver forearm, (2) the effect of forearm rotation and wrist extension on measured BMD around TWA in a cadaver, and (3) the precision of DXA in a cadaver and patients. METHODOLOGY One ROI around the distal and 1 and 3 ROIs (ROI1-3) around the proximal component were used. Ten DXA scans were performed on forearm and femur mode convertible to orthopedic knee mode without arthroplasty, with ReMotion, and with Motec TWA in one cadaver forearm. Ten scans with 5° increments from 90°-70° pronation and 0°-20° extension, were performed with Motec. Precision was calculated as coefficient of variation (CV%) and least significant change (LSC%) from cadaver scans and double examinations with femur mode converted to orthopedic knee mode in 40 patients (20 ReMotion, 20 Motec). RESULTS BMD was higher in all Motec than corresponding ReMotion ROIs (p < 0.05). BMD changed with 10° supination in the distal ROI and ROI1, and with 5° extension in the distal ROI (p < 0.05). In the cadaver the orthopedic knee mode was more precise than the forearm mode in 3 Motec ROIs (p < 0.05). In patients CV was 2.21%-3.08% in the distal ROI, 1.66%-2.01% in the proximal ROI, and 1.98%-2.87% with 3 ROIs. CONCLUSIONS DXA is feasible for BMD measurement around the proximal component using the orthopedic knee mode, but not the distal component of TWA.
Collapse
Affiliation(s)
- Trygve Holm-Glad
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
| | - Kristin Godang
- Section of specialized endocrinology, Oslo University hospital, Oslo, Norway
| | - Jens Bollerslev
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway; Section of specialized endocrinology, Oslo University hospital, Oslo, Norway
| | - Magne Røkkum
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Ole Reigstad
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
24
|
de Waard S, Sierevelt IN, Jonker R, Hoornenborg D, van der Vis HM, Kerkhoffs GMMJ, Haverkamp D. The migration pattern and initial stability of the Optimys short stem in total hip arthroplasty: a prospective 2-year follow-up study of 33 patients with RSA. Hip Int 2021; 31:507-515. [PMID: 31971010 DOI: 10.1177/1120700020901844] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND PURPOSE The consensus that bone stock preservation and optimal restoration of offset and leg length is important in total hip arthroplasty is now widespread, especially for young and active patients. Short stems seem promising in this aspect, though implant stability is still of concern. This study looked at the migration pattern of the Optimys short stem through RSA analysis. PATIENTS AND METHODS 40 patients were included. RSA images were made directly postoperatively (within 5 days), at 6 weeks and at 3, 6, 12 and 24 months. Double examinations were made for precision measurement. HOOS and pain scores were obtained preoperatively and at 2 years. 4 patients were excluded due to protocol violation and 1 patient was excluded for RSA analysis with a CN number >110. 2 patients were lost to follow-up after 3 and 6 months (n = 1 lost, n = 1 deep infection, respectively). RESULTS Mean age was 60 years with a mean BMI of 27. RSA analysis of 34 patients showed a significant initial median proximodistal translation (subsidence) of 0.21 mm (IQR 0.64-0.06) and anteversion-retroversion rotation of 0.59° (IQR 0.01-1.34) at 6 weeks, after which the stem stabilises and showed no further significant movement. Median migration in other directions was small. 4 patients had an initial subsidence of >2 mm, all showed secondary stabilisation. HOOS outcomes were satisfactory, with the domain symptoms and pain showing a median score of 95/100 at 2 years. CONCLUSIONS After initial migration the Optimys achieves secondary stabilisation, suggesting low risk on long-term aseptic loosening. CLINICAL TRIALS REGISTRATION NL47055.048.13.
Collapse
Affiliation(s)
- Sheryl de Waard
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands.,Academic Medical Centre (AMC), Amsterdam, Netherlands
| | - Inger N Sierevelt
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Renee Jonker
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Daniel Hoornenborg
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Harm M van der Vis
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | | | - Daniël Haverkamp
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| |
Collapse
|
25
|
Brodt S, Jacob B, Nowack D, Zippelius T, Strube P, Matziolis G. An Isoelastic Monoblock Cup Retains More Acetabular and Femoral Bone Than a Modular Press-Fit Cup: A Prospective Randomized Controlled Trial. J Bone Joint Surg Am 2021; 103:992-999. [PMID: 33617161 DOI: 10.2106/jbjs.19.00787] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND For cup revision after total hip arthroplasty, sufficiently good periacetabular bone stock is a prerequisite for fixation of the revision implant. Cementless cups can lead to a relevant reduction of peri-implant bone mineral density (BMD) through stress-shielding. METHODS Fifty patients were included in this prospective randomized controlled trial. Group 1 (RM group) received an isoelastic monoblock cup (RM Pressfit vitamys; Mathys). Group 2 (IT group) received a modular titanium cup (Allofit-S IT Alloclassic with a polyethylene liner; Zimmer). Periacetabular BMD was determined and subdivided into 4 regions of interest by dual x-ray absorptiometry at 1 week (baseline) and at 4 years postoperatively. Our primary outcome was reduction in periacetabular BMD. RESULTS Periacetabular BMD was reduced by an average of 15.1% in the RM group and 16.5% in the IT group at 4 years postoperatively. No significant difference was found between the 2 groups over the periacetabular structure as a whole. However, the decrease of BMD in the polar region was significantly different in the RM group (4.9% ± 10.0%) compared with the IT group (15.9% ± 14.9%, p = 0.005). Use of the isoelastic RM cup showed significantly less bone loss than the modular IT cup. CONCLUSIONS Relevant loss of BMD at 4 years after surgery was identified in the periacetabular region in both groups. No differences between the 2 cup systems were found when looking at the overall periacetabular region. As a secondary outcome, less postoperative periacetabular bone loss occurred in the polar region when an isoelastic cup was used. Longer follow-up is required to allow for conclusions to be drawn about the long-term course of the 2 cup systems. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Steffen Brodt
- Department of Orthopedics, Jena University Hospital, Campus Eisenberg, Germany
| | | | | | | | | | | |
Collapse
|
26
|
Munakata Y, Kuramitsu Y, Usui Y, Okazaki K. Comparison of radiographic changes in rectangular curved short stem with thin versus thick porous coating for cementless total hip arthroplasty: a retrospective study with a propensity score matching. J Orthop Surg Res 2021; 16:247. [PMID: 33849591 PMCID: PMC8042942 DOI: 10.1186/s13018-021-02397-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 04/05/2021] [Indexed: 11/12/2022] Open
Abstract
Background Radiographic changes that appear relatively quickly after fixation of cementless stem in total hip arthroplasty (THA) vary depending on the stem design and fixation style. The present study compared radiographic changes between two types of rectangular curved short stems of similar shape. Methods This retrospective study included 118 hips that underwent primary cementless THA with an anterolateral supine approach using a rectangular, curved, short stem performed by the same surgeon between June 2015 and June 2019. Among the examined hips, 39 had a thicker porous coating stem (thicker group) and 66 had a thinner porous coating and reduced tip stem (thinner group) and at least 12-month follow-up. Radiographs taken during the final course observation were assessed. Propensity score matching was performed based on demographic data and comparisons were made using pairs of 25 hips each. Statistical analysis was performed using chi-square test and p values ≤ 0.05 indicated statistical significance. Results The pattern of the radiolucent lines showed a significant difference after matching (p = 0.0044). A “proximal and distal” pattern was most common in the thicker group and a “distal only” pattern was most common in the thinner group. There was notable and significant difference in cortical hypertrophy in the thicker group after matching (p = 0.024). Conclusions Although the two short stems were similar shapes, the short-term radiographic changes were different. The thinner group showed fewer radiographic changes than the thicker group, making it a more “silent” stem.
Collapse
Affiliation(s)
- Yutaro Munakata
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Yujiro Kuramitsu
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Yutaka Usui
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.
| |
Collapse
|
27
|
Won SH, Park JW, Lee YK, Ha YC, Koo KH. No Clinically Important Differences in Thigh Pain or Bone Loss Between Short Stems and Conventional-length Stems in THA: A Randomized Clinical Trial. Clin Orthop Relat Res 2021; 479:767-777. [PMID: 33009239 PMCID: PMC8083837 DOI: 10.1097/corr.0000000000001505] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 08/26/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Short-length stems were developed to reduce bone loss of the proximal femur and potentially decrease the incidence of thigh pain after cementless THA. However, it remains unknown whether short stems indeed reduce bone loss or the frequency of thigh pain. QUESTIONS/PURPOSES Is there a difference between short- and standard-length stems in terms of: (1) the frequency or severity of thigh pain, (2) modified Harris hip scores, (3) implant loosening, or (4) bone mineral density as measured by dual-energy x-ray absorptiometry? METHODS Between March 2013 and January 2014, three surgeons performed 205 primary THAs. To be eligible, patients needed to be at least 20 years of age, have not undergone previous history of hip surgery, and have no metabolic bone disease. A total of 100 patients were randomized to receive THA either with a short stem (n = 56) or with a standard-length stem (n = 44). Both stems were proximally coated, tapered, cementless stems. Compared with standard stems, short stems typically were 30- to 35-mm shorter. A total of 73% (41 of 56) and 77% (34 of 44) of those groups, respectively, were accounted for at a minimum of 5 years and were analyzed. The presence of thigh pain during activity was evaluated using a 10-point VAS, and the modified Harris hip score was calculated by research assistants who were blinded to the treatment groups. Plain radiographs were taken at 6 weeks, 6 months, and 12 months postoperatively, and every 1 year thereafter; loosening was defined as subsidence > 3 mm or a position change > 3° on serial radiographs. Radiological assessment was performed by two researchers who did not participate in the surgery and follow-up evaluations. Bone mineral density of the proximal femur was measured using dual-energy x-ray absorptiometry at 4 days, 1 year, 2 years, and 5 years postoperatively. The primary endpoint of our study was the incidence of thigh pain during 5-year follow-up. Our study was powered at 80% to detect a 10% difference in the proportion of patients reporting thigh pain at the level of 0.05. RESULTS With the numbers available, we found no difference between the groups in the proportion of patients with thigh pain; 16% (9 of 56) of patients in the short-stem group and 14% (6 of 44) of patients in the standard-stem group experienced thigh pain during the follow-up period (p = 0.79). In all patients, the pain was mild or moderate (VAS score of 4 or 6 points). Among the 15 available patients who reported thigh pain, there was no difference between the implant groups in mean severity of thigh pain (4.3 ± 0.8 versus 4.2 ± 0.7; p = 0.78). There were no between-group differences in the short versus standard-length stem groups in terms of mean modified Harris hip score by 5 years after surgery (89 ± 13 versus 95 ± 7 points; p = 0.06). No implant was loose and no hip underwent revision in either group. Patients in the short-stem group showed a slightly smaller decrease in bone mineral density in Gruen Zones 2, 3, and 5 than those in the standard-stem group did; the magnitude of the difference seems unlikely to be clinically important. CONCLUSION We found no clinically important differences (and few differences overall) between short and standard-length THA stems 5 years after surgery in a randomized trial. Consequently, we recommend that clinicians use standard-length stems in general practice because standard-length stems have a much longer published track record in other studies, and short stems can expose patients to the uncertainty associated with novelty, without any apparent offsetting benefit. LEVEL OF EVIDENCE Level I, therapeutic study.
Collapse
MESH Headings
- Absorptiometry, Photon
- Adult
- Arthralgia/diagnosis
- Arthralgia/etiology
- Arthralgia/physiopathology
- Arthralgia/prevention & control
- Arthroplasty, Replacement, Hip/adverse effects
- Arthroplasty, Replacement, Hip/instrumentation
- Biomechanical Phenomena
- Bone Density
- Female
- Hip Joint/diagnostic imaging
- Hip Joint/physiopathology
- Hip Joint/surgery
- Hip Prosthesis
- Humans
- Male
- Middle Aged
- Osteoporosis/diagnostic imaging
- Osteoporosis/etiology
- Osteoporosis/physiopathology
- Osteoporosis/prevention & control
- Pain Measurement
- Pain Threshold
- Pain, Postoperative/diagnosis
- Pain, Postoperative/etiology
- Pain, Postoperative/physiopathology
- Pain, Postoperative/prevention & control
- Prosthesis Design
- Range of Motion, Articular
- Recovery of Function
- Republic of Korea
- Time Factors
- Treatment Outcome
Collapse
Affiliation(s)
- Seok-Hyung Won
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Jung-Wee Park
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Young-Kyun Lee
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Yong-Chan Ha
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Kyung-Hoi Koo
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| |
Collapse
|
28
|
Bostian PA, Grisez BT, Klein AE, Frye BM. Complex Primary Total Hip Arthroplasty: Small Stems for Big Challenges. Arthroplast Today 2021; 8:150-156. [PMID: 33786353 PMCID: PMC7994729 DOI: 10.1016/j.artd.2021.02.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 02/15/2021] [Accepted: 02/23/2021] [Indexed: 11/15/2022] Open
Abstract
Total hip arthroplasty is one of the most successful operations in all of medicine. Femoral deformities from malunion, prior osteotomy, and retained surgical implants all present unique challenges. Corrective osteotomy and hardware removal add significant morbidity to an operation that typically has a fast recovery. Short stems can be used in these cases to spare patients' increased morbidity. We present a case-based illustration and surgical technique for the use of short stems in complex primary total hip arthroplasty with femoral deformity and retained hardware. We discuss how these implants can spare significant morbidity, show radiographic examples of their use, and present short-term outcomes.
Collapse
Affiliation(s)
- Phillip A Bostian
- Department of Orthopaedics, West Virginia University, Morgantown, WV, USA
| | - Brian T Grisez
- Department of Orthopaedics, West Virginia University, Morgantown, WV, USA
| | - Adam E Klein
- Department of Orthopaedics, West Virginia University, Morgantown, WV, USA
| | - Benjamin M Frye
- Department of Orthopaedics, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
29
|
Pons-Cabrafiga M, Arias de la Torre J, Berlanga-de-Mingo D, Lobo-Escolar L. Is diaphyseal fixation of short neck-retaining stem prostheses related to the size of the implant? Hip Int 2021; 31:196-200. [PMID: 32538203 DOI: 10.1177/1120700020932937] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Short-stem hip prostheses present variable proximal femoral bone radiological findings. The aims of this study were to analyse, in our patients with implanted collum femoris-preserving (CFP) stems, cancellous bone remodelling, cortical distal hypertrophy and pedestal formation, and the relationship between those radiological changes that suggest distal fixation with the size of the stem. METHODS From October 2001 to December 2012 a total of 199 consecutive primary total hip arthroplasties in 180 patients were performed at our department using the CFP stem and followed up for a minimum of 5 years until December 2017. RESULTS Stress shielding was present in 74% of oversized stems cases, but in normal or undersized stems, stress shielding was present in 8.5%. Cortical hyperthrophy was observed in 49% of the oversized stems and in 6% of the normal or undersized ones. Finally, non-statistically significant differences (p = 0.089) in pedestal formation were found, present in 16.3% of the oversized stems and in 6% of normal or undersized ones. CONCLUSIONS Oversized stems cause more stress shielding and distal cortical hypertrophy in the distal part of the stem, which indicates distal fixation in bigger sizes of stem.
Collapse
|
30
|
Zhang Z, Xing Q, Li J, Jiang Z, Pan Y, Hu Y, Wang L. A comparison of short-stem prostheses and conventional stem prostheses in primary total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:231. [PMID: 33708858 PMCID: PMC7940904 DOI: 10.21037/atm-20-4043] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Background In total hip arthroplasty (THA), short-stem prostheses (SS) were designed to achieve better preservation of proximal femoral bone stock and stability than conventional stem prostheses (CS), however these effects are controversial. We aimed perform a systematic review and meta-analysis to evaluate the effectiveness of SS and CS in primary THA. Methods Relevant randomized controlled trials (RCTs) involving the comparison of SS and CS in primary THA were screened using the electronic databases PubMed, Embase and Web of Science. Data were analyzed with the RevMan 5.3 software program and evaluated with mean difference (MD), risk ratio (RR) and 95% confidence intervals (CIs) by random or fixed-effect models. Results Sixteen RCTs involving 1,233 patients (1,486 hips) were included. Compared with CS, the incidence of thigh pain was significantly reduced with Proxima SS (RR 0.13, 95% CI, 0.03–0.51; P=0.004). Bone mineral density (BMD) with femoral neck-preserved SS [SS (I)] showed less decrease in Gruen zone 1 (MD 14.60, 95% CI, 10.67–18.54; P<0.00001) and Gruen zone 7 (MD 9.72, 95% CI, 5.21–14.23; P<0.0001) than CS. However, the changes of BMD were not significantly different between the SS without femoral neck preservation group [SS (II)] and the CS group. In addition, no significant differences were found in the revision rate, Harris Hip Score (HHS), or maximum total point motion (MTPM) between the SS and CS groups. Conclusions The results of this study showed that compared with CS, Proxima SS decreased the incidence of thigh pain and that SS (I) provided better proximal bone remodeling than CS. But the revision rates, HHS, and MTPM between SS and CS were similar. However, the findings of this meta-analysis require further verification in high-quality RCTs.
Collapse
Affiliation(s)
- Zhen Zhang
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| | - Qiqi Xing
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| | - Jingyi Li
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| | - Zichao Jiang
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| | - Yixiao Pan
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| | - Yihe Hu
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| | - Long Wang
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
31
|
Slullitel PA, Mahatma MM, Farzi M, Grammatopoulos G, Wilkinson JM, Beaulé PE. Influence of Femoral Component Design on Proximal Femoral Bone Mass After Total Hip Replacement: A Randomized Controlled Trial. J Bone Joint Surg Am 2021; 103:74-83. [PMID: 33079901 DOI: 10.2106/jbjs.20.00351] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND In this randomized controlled trial (RCT), we compared bone remodeling and bone turnover between 2 total hip arthroplasty implants-the short, proximally porous-coated Tri-Lock Bone-Preservation Stem and a conventional, fully-coated Corail prosthesis-over a 2-year postoperative period. METHODS Forty-six participants received the Tri-Lock prosthesis and 40 received the Corail prosthesis. At baseline, the 2 groups had similar demographics, proximal femoral bone mineral density (BMD), bone turnover markers, radiographic canal flare index, and patient-reported outcome measure (PROM) scores. Outcomes were measured at weeks 26, 52, and 104. RESULTS Loss of periprosthetic bone, measured by high-sensitivity dual x-ray absorptiometry region-free analysis (DXA-RFA), was identified at the calcar and proximal-lateral aspect of the femur in both prosthesis groups (p < 0.05). However, the conventional prosthesis was associated with a smaller reduction in BMD compared with the bone-preservation prosthesis (p < 0.001). This effect was most prominent in the region of the femoral calcar and greater trochanter. A small gain in BMD was also identified in some areas, and this gain was greater with the conventional than the bone-preservation prosthesis (p < 0.001). The 2 groups had similar changes in bone turnover markers and improvement in PROM scores over the study period (p > 0.05). The adverse-event rate was also similar between the groups (p > 0.05). CONCLUSIONS This RCT shows that prostheses intended to preserve proximal femoral bone do not necessarily perform better in this regard than conventional cementless designs. DXA-RFA is a sensitive tool for detecting spatially complex patterns of periprosthetic bone remodeling. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Pablo A Slullitel
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.,Institute of Orthopaedics 'Carlos E. Ottolenghi', Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Mohit M Mahatma
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom
| | - Mohsen Farzi
- Centre for Computational Imaging and Simulation Technologies in Bioscience, University of Leeds, Leeds, United Kingdom
| | | | - J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom
| | - Paul E Beaulé
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
| |
Collapse
|
32
|
Blakeney WG, Lavigne M, Beaulieu Y, Puliero B, Vendittoli PA. Mid-term results of total hip arthroplasty using a novel uncemented short femoral stem with metaphyso-diaphyseal fixation. Hip Int 2021; 31:83-89. [PMID: 31996038 DOI: 10.1177/1120700020903451] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE Short stems were developed with the promise of providing easier implantation, facilitating revision, reducing thigh pain and proximal stress shielding. The aim of this study is to present the mid-term clinical results of a titanium short stem with modular neck. METHODS This is a prospective case series of 144 THAs performed on a series of 131 patients using the PROFEMUR Preserve Femoral Stem (MicroPort Orthopedics, Arlington, TN, USA). 2 surgeons, operated on the patients using a mini-posterior approach. The primary outcomes evaluated were stem revision for aseptic loosening and all-cause stem revision. Clinical and radiographic outcomes were also assessed. RESULTS Of the 144 THAs, there were 43 males and 101 females, with an average age of 61 (range 22-92) years at surgery. After a mean of 78 (range 53-87) months follow-up, there were 2 (1.5%) femoral implant revisions; 1 for early femoral periprosthetic fracture and 1 for fatigue failure of the modular femoral neck. There were no cases of stem aseptic loosening and radiographic analysis demonstrated no cases of stem migration. The mean UCLA activity, WOMAC and Fogotten Joint scores were respectively 6.1, 10.7 and 86.6. 70% of prosthetic hips were observed as having no restriction and 99.2% of patients were satisfied with their THA. CONCLUSIONS This short modular stem produced satisfactory clinical and radiological results at mid-term, with 98.5% implant survival for any cause of stem revision and no revisions for aseptic loosening. Long-term results are required to further evaluate the stem's promising early results.
Collapse
Affiliation(s)
- William G Blakeney
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hospital Maisonneuve-Rosemont, Montreal, Quebec, Canada
| | - Martin Lavigne
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hospital Maisonneuve-Rosemont, Montreal, Quebec, Canada
| | - Yann Beaulieu
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hospital Maisonneuve-Rosemont, Montreal, Quebec, Canada
| | - Benjamin Puliero
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hospital Maisonneuve-Rosemont, Montreal, Quebec, Canada
| | - Pascal-André Vendittoli
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hospital Maisonneuve-Rosemont, Montreal, Quebec, Canada.,Department of Surgery, University of Montreal, Canada
| |
Collapse
|
33
|
Neck-sparing short femoral stems: A meta-analysis. Orthop Traumatol Surg Res 2020; 106:1481-1494. [PMID: 32703717 DOI: 10.1016/j.otsr.2020.05.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 05/05/2020] [Accepted: 05/11/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Neck sparing short femoral stems are supposed to ease restoration of the proximal femoral anatomy and physiological hip biomechanics. This stem design is of particular interest as they have the potential to generate prosthetic hips that have higher functional performance with an improved lifespan, and revise more easily. Unlike previously published meta-analysis, this meta-analysis was initiated to determine if neck sparing short femoral stems compared to conventional stems: (1) resulted in improved functional performance; (2) reduced risk of thigh pain; (3) reduced risk of reoperation/revision, and 4) reduced stress shielding related bone loss in the proximal femur. MATERIAL AND METHODS Literature databases were searched between 1st January 2005 and 30th March 2019. The primary search was conducted using the electronic databases MEDLINE, EMBASE, PubMed, Open Grey, Trip Pro, Evidence Search, and Cochrane. Eligible studies were assessed for homogeneity, with continuous outcomes expressed as standardized mean difference with 95% confidence interval and dichotomous data as odds-ratio with 95% confidence interval. RESULTS Ten randomised clinical trials were eligible; these trials included 1259 total hip arthroplasty procedures, inclusive of 616 neck sparing short stems and 643 conventional stems. We were not able to find a significant functional advantage of using neck sparing short stems based on Harris Hip scores (0.0850; 95% CI: -0.03 to 0.20 [p=0.40]) and WOMAC scores (-0.0605; 95% CI: -0.03 to 0.15 [p=0.87]). We found a trend in favour of neck sparing short stems to reduce the risk of thigh pain but this was non significant (odds ratio of 0.11; 95% CI: 0.03 to 0.43 [p=0.178]). Neck sparing short stems were associated with similar early- to mid-term dislocation and revision rates compared to conventional stems with odds ratio of 1.435 (95% CI: 0.545 to 3.780 [p=0.968]) and of 0.581 (95% CI: 0.220 to 1.532 [p=0.972]), respectively. Neck sparing short stems were found to have less bone loss in both Gruen zones 1 and 7 (3.324; 95% CI: -7.683 to 1.036 [p<0.001], and of -4.632; 95% CI: -9682 to 0.418 [p<0.001], respectively). DISCUSSION/CONCLUSION Neck sparing short femoral stems achieve excellent early to mid-term outcomes in both clinical and radiological outcome scores that are in keeping with conventional stems functionally. Hitherto, results from this meta-analysis suggest that neck-sparing stems may achieve better maintenance of bone mineral density than their conventional counterparts, in addition to fewer cases of thigh pain. LEVEL OF EVIDENCE I; meta-analysis.
Collapse
|
34
|
李 永, 何 荣, 张 谦, 安 明, 祁 辉, 马 文, 宋 兴, 孙 俊. [Bone remodeling after total hip arthroplasty with anatomic medullary locking prosthesis and its long-term effectiveness]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2020; 34:689-695. [PMID: 32538557 PMCID: PMC8171526 DOI: 10.7507/1002-1892.201910033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 02/20/2020] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To investigate the femoral bone remodeling and long-term effectiveness of total hip arthroplasty (THA) with anatomic medullary locking (AML) prosthesis. METHODS The clinical data of 24 cases (26 hips) who were treated with THA with AML prosthesis between November 1997 and January 2003 were retrospectively analyzed. There were 12 males and 12 females with an age of 32-69 years (mean, 53.7 years). There were 5 cases (5 hips) of avascular necrosis of the femoral head, 6 cases (7 hips) of secondary osteoarthritis of the hip dysplasia, 6 cases (6 hips) of femoral neck fracture, 2 cases (2 hips) of primary osteoarthritis, 3 cases (3 hips) of revision surgery, 1 case (2 hips) of ankylosing spondylitis, 1 case (1 hip) of femoral head fracture. The patients were followed up at immediate, 6 weeks, 3 months, 6 months, 1 year, and then every year after operation for imaging evaluation (X-ray film was taken immediately after operation to evaluate the femoral isthmus compression, Engh standard was used to evaluate the biological fixation of the femoral shaft prosthesis, and Brooker method was used to evaluate the occurrence of heterotopic ossification); bone reconstruction evaluation [reconstruction of prosthesis and bone interface (type of bone reaction, Gruen zone, incidence, and occurrence time were recorded), reconstruction of bone around prosthesis (proximal femur stress shielding bone absorption was evaluated according to Engh and Bobyn methods, and bone mineral density change rate was measured)]; clinical efficacy evaluation [Harris score for efficacy, visual analogue scale (VAS) score for thigh pain]. RESULTS All patients were followed up 15 years and 2 months to 20 years and 4 months, with a median of 16 years and 6 months. At immediate after operation, 24 hips (92.3%) had good femoral isthums compression, 24 hips (92.3%) had good bone ingrowth. Heterotopic ossification occurred in 2 patients with degree 1, 2 patients with degree 2, and 1 patient with degree 3 at 3-6 months after operation. Hyperplastic bone reactions were more common in Gruen 2, 3, 4, 5, 6, 10, 11, and 12 zones, mainly occurring at 6-20 months after operation, with the incidence of 3.8%-69.2%, with the highest incidence of spot welding. All absorptive bone reactions were osteolysis, which was common in Gruen 1 and 7 zones, and mainly occurred at 8 years after operation, with an incidence of 42.3%. No clear line (area) or enlarged sign of medullary cavity was observed. Twenty-one hips (80.8%) had 1 degree stress shieding, and 5 hips (19.2%) had 2 degree stress shieding. It mainly occurred at 10-24 months after operation in Gruen 1 and 7 zones. Dual energy X-ray absorptiometry showed that bone mineral density mainly decreased in Gruen 1, 2, 6, and 7 zones, mainly increased in Gruen 3, 4, and 5 zones. Bone mineral density loss progressed slowly after 2 years of operation, and it was stable in 5-8 years, but decreased rapidly in 8-9 years, and stabilized after 10 years. The Harris score increased from 51.1±6.2 before operation to 88.3±5.1 at last follow-up ( t=-21.774, P=0.000). Mild thigh pain occurred in only 2 cases (7.7%) with the VAS score of 2. No aseptic loosening or revision of femoral prosthesis occurred during the follow-up. CONCLUSION The application of AML prosthesis in THA has a good bone remodeling and a good long-term effectiveness.
Collapse
Affiliation(s)
- 永旺 李
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 荣丽 何
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 谦 张
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 明 安
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 辉 祁
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 文海 马
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 兴建 宋
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| | - 俊英 孙
- 保定市第一中心医院骨三科(河北保定 071000)Third Department of Orthopedics, Baoding Municipal First Center Hospital, Baoding Hebei, 071000, P.R.China
| |
Collapse
|
35
|
Vajapey SP, Morris J, Li D, Greco NG, Li M, Spitzer AI. Outcome Reporting Patterns in Total Hip Arthroplasty. JBJS Rev 2020; 8:e0197. [DOI: 10.2106/jbjs.rvw.19.00197] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
36
|
Migliorini F, Driessen A, Colarossi G, El Mansy Y, Gatz M, Tingart M, Eschweiler J. Short stems for total hip replacement among middle-aged patients. INTERNATIONAL ORTHOPAEDICS 2020; 44:847-855. [PMID: 32193611 DOI: 10.1007/s00264-020-04516-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Accepted: 02/24/2020] [Indexed: 12/23/2022]
Abstract
INTRODUCTION The purpose of the present study was to investigate the role of short stem implants for primary total hip arthroplasty in middle-aged patients. For this purpose, a meta-analysis of the current literature was conducted. The focus was on clinical outcomes,radiological parameters, and further complications of both components. MATERIAL AND METHODS The study was performed according to the PRISMA guidelines. All randomized and non-randomized clinical trials comparing short stem versus standard stem prostheses for THA were considered for inclusion. Only studies reporting data concerning uncemented stems for primary total hip arthroplasty were included. Only studies reporting data concerning patients with a mean age of 45 to 69 were included. RESULTS A total of 2197 procedures in 2116 patients were analysed. The mean follow-up was 30.2 months. The short stem group showed a statistically significant higher WOMAC score and a reduced total estimated blood loss compared with the standard stem group. The short stem group showed a reduced rate of femoral fractures, dislocations, and revision, but without statistical significance. CONCLUSIONS According to the main findings of this meta-analysis and current evidence, we encourage the use of the uncemented short stems during primary total hip arthroplasty in middle-aged patients.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
| | - Arne Driessen
- Department of Orthopaedic Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Giorgia Colarossi
- Department of Thoracic Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - Yasser El Mansy
- Department of Orthopaedic Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.,Department of Orthopaedics and Traumatology, Alexandria University, Alexandria, Egypt
| | - Matthias Gatz
- Department of Orthopaedic Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Markus Tingart
- Department of Orthopaedic Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Jörg Eschweiler
- Department of Orthopaedic Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| |
Collapse
|
37
|
Thalmann C, Horn Lang T, Bereiter H, Clauss M, Acklin YP, Stoffel K. An excellent 5-year survival rate despite a high incidence of distal femoral cortical hypertrophy in a short hip stem. Hip Int 2020; 30:152-159. [PMID: 31010329 DOI: 10.1177/1120700019834336] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Although reported results on short stems sound very promising, the occurrence of distal femoral cortical hypertrophy is often observed. The aim of the present study was to report 5-year survival data of a commercially available trochanter sparing short stem and investigate the clinical impact of distal femoral cortical hypertrophy on the outcome. METHODS 123 total hip arthroplasties were performed on 120 patients from April 2008 to May 2010 (mean age 62, range 29-89 years; 71 hips from male patients, 58%). Clinical and radiological data were collected preoperative, at 6 weeks, 1, 2, 3, and 5 years postoperative to assess the outcome. Radiographs taken immediately postoperative as well as 1 and 5 years postoperative were used to identify and assess cortical hypertrophy. RESULTS 1 stem had to be revised due to aseptic loosening, resulting in a Kaplan-Meier survival analysis with endpoint for stem revision of 99.2% (95% Confidence Interval 94.1-99.9) at 5 years. 96 radiological and 95 clinical follow-ups were analysed 5 years postoperative. 68 (71%) hips showed distal femoral cortical hypertrophy after 5 years. The average Harris Hip Score and Oxford Hip Score improved 33 (standard deviation (SD) 15.1, range 2-70), 18 (SD 12.1, range -10-43) points, respectively. Overall 16% of the patients reported thigh pain, unrelated to the presence of cortical hypertrophy. DISCUSSION This short stem shows an excellent 5-year survival rate and good clinical outcome despite a high incidence of cortical hypertrophy. However, the question of the mechanism of load transfer arises.
Collapse
Affiliation(s)
| | - Tamara Horn Lang
- Clinic for Orthopaedic and Trauma Surgery, Kantonsspital Baselland, Bruderholz, Switzerland
| | - Heinz Bereiter
- Orthopaedic Surgery, Kantonsspital Graubünden, Chur, Switzerland
| | - Martin Clauss
- Clinic for Orthopaedic and Trauma Surgery, Kantonsspital Baselland, Bruderholz, Switzerland
| | - Yves P Acklin
- Clinic for Orthopaedic and Trauma Surgery, Kantonsspital Baselland, Bruderholz, Switzerland
| | - Karl Stoffel
- Clinic for Orthopaedic and Trauma Surgery, Kantonsspital Baselland, Bruderholz, Switzerland
| |
Collapse
|
38
|
Hu H, Liu Z, Liu B, Ding X, Liu S, Wu T, Ma W, Han Y. Comparison of Clinical Outcomes, Radiological Outcomes and Bone Remodeling Outcomes Between Proximal Coated Single-Wedge New Stem and Full Coated Dual-Wedge Classic Stem in 1-Stage Bilateral Total Hip Arthroplasty. Med Sci Monit 2020; 26:e921847. [PMID: 32001666 PMCID: PMC7006600 DOI: 10.12659/msm.921847] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Background This retrospective study investigated the clinical outcomes, radiological outcomes, and bone remodeling patterns associated with a Medial/Lateral Taper (M/L Taper) stem and Link Classic Uncemented (LCU) stem in 1-stage bilateral total hip arthroplasty (THA). Material/Methods The results of 52 patients who underwent 1-stage bilateral THA with a M/L Taper stem on one side and an LCU stem on the other between January 2012 and February 2015 were retrospectively compared. Patients were clinically assessed by the Harris hip score (HHS), visual analogue score (VAS) and incidence of complications. Radiological indicators were measured. Periprosthetic bone remodeling was assessed via bone mineral density (BMD) measurements. Results The mean follow-up time was 5.2 years. At each follow-up, there was no difference in the HHS and VAS between the 2 groups. The neck-shaft angle, offset, vertical height of the rotational center and limb lengthening were lower in the M/L Taper group than in the LCU group (P<0.001). The Engh total score was lower in the LCU group (P=0.039). Significantly higher (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 1, 2, and 6. significantly lower (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 3 and 5. Conclusions Due to the increased postoperative neck-shaft angle, the full coated dual-wedge classic stem was prone to cause lower limb lengthening. The proximal coated single-wedge new stem patients were more likely to have an insufficient postoperative neck length. The new stem achieved load transfer and proximal fixation, leading to better proximal femoral bone preservation is more in line with human biomechanical characteristics.
Collapse
Affiliation(s)
- Hongpeng Hu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Zeming Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Bo Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Xuzhuang Ding
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Sikai Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Tao Wu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Wenhui Ma
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Yongtai Han
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| |
Collapse
|
39
|
Hochreiter J, Mattiassich G, Ortmaier R, Steinmair M, Anderl C. Femoral bone remodeling after short-stem total hip arthroplasty: a prospective densitometric study. INTERNATIONAL ORTHOPAEDICS 2020; 44:753-759. [PMID: 31965311 DOI: 10.1007/s00264-020-04486-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Accepted: 01/15/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE Due to improved prosthesis designs and surgical techniques, indications for total hip arthroplasty (THA) now include younger and more active patients. Preserving bone stock and soft tissue in these patients is paramount to allow for future revision. Designed for anatomical reconstruction, short femoral stems have the potential to reduce adaptive bone loss and stress shielding. To confirm this, we evaluated bone remodeling around a short femoral stem and the accuracy of hip joint reconstruction. METHODS This prospective observational study involved 46 patients with short-stem THA for clinical and radiographic analysis. We evaluated bone remodeling by Gruen zone using dual-energy X-ray absorptiometry in 45 patients and assessed the accuracy of hip joint reconstruction using caput-collum-diaphyseal angles. Additionally, we reported functional scores and pain. RESULTS Patients were followed for a mean of 24.1 (SD 2.2) months. Bone mineral density increased mainly in the lateral region (Gruen zones 2 and 3) and in the distal-medial region (Gruen zone 5), suggestive of lateral loading. Most caput-collum-diaphyseal angles remained stable after surgery, especially in patients with varus hips. Harris Hip Scores improved significantly, from 57.2 (SD 20.0) pre-operatively to 97.2 (SD 4.0) at 24 months post-operatively (P < 0.0001). Finally, we encountered one peri-operative dislocation but no post-operative complications. CONCLUSION Short femoral stems successfully limited stress shielding and minimized periprosthetic bone loss without compromising primary stability. We were able to accurately reconstruct anatomical relationships in most patients. Finally, excellent clinical outcomes and low complication rates confirmed the favourable results of short-stem THA. TRIAL REGISTRATION DRKS00017076.
Collapse
Affiliation(s)
- Josef Hochreiter
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.
| | - Georg Mattiassich
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.,Ludwig-Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - Reinhold Ortmaier
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.,Research Unit of Orthopedic Sports Medicine and Injury Prevention, Institute for Sports Medicine, Alpine Medicine and Health Tourism (ISAG), UMIT, Eduard-Wallnöfer-Zentrum 1, 6060, Hall in Tirol, Austria
| | - Martin Steinmair
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria
| | - Conrad Anderl
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria
| |
Collapse
|
40
|
Klasan A, Bäumlein M, Dworschak P, Bliemel C, Neri T, Schofer MD, Heyse TJ. Short stems have lower load at failure than double-wedged stems in a cadaveric cementless fracture model. Bone Joint Res 2019; 8:472-480. [PMID: 31728187 PMCID: PMC6825045 DOI: 10.1302/2046-3758.810.bjr-2019-0051.r1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Objectives Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies. The purpose of this study was a direct load-to-failure comparison of a double-wedged cementless stem and a short cementless stem in a cadaveric fracture model. Methods Eight hips from four human cadaveric specimens (age mean 76 years (60 to 89)) and eight fourth-generation composite femurs were used. None of the cadaveric specimens had compromised quality (mean T value 0.4 (-1.0 to 5.7)). Each specimen from a pair randomly received either a double-wedged stem or a short stem. A materials testing machine was used for lateral load-to-failure test of up to a maximal load of 5000 N. Results Mean load at failure of the double-wedged stem was 2540 N (1845 to 2995) and 1867 N (1135 to 2345) for the short stem (p < 0.001). All specimens showed the same fracture pattern, consistent with a Vancouver B2 fracture. The double-wedged stem was able to sustain a higher load than its short-stemmed counterpart in all cases. Failure force was not correlated to the bone mineral density (p = 0.718). Conclusion Short stems have a significantly lower primary load at failure compared with double-wedged stems in both cadaveric and composite specimens. Surgeons should consider this biomechanical property when deciding on the use of short femoral stem. Cite this article: A. Klasan, M. Bäumlein, P. Dworschak, C. Bliemel, T. Neri, M. D. Schofer, T. J. Heyse. Short stems have lower load at failure than double-wedged stems in a cadaveric cementless fracture model. Bone Joint Res 2019;8:489–494. DOI: 10.1302/2046-3758.810.BJR-2019-0051.R1.
Collapse
Affiliation(s)
- Antonio Klasan
- Center for Orthopedics and Traumatology, University Hospital Marburg, Marburg, Germany; Sydney Orthopaedic Research Institute, Australia
| | - Martin Bäumlein
- Center for Orthopedics and Traumatology, University Hospital Marburg, Marburg, Germany
| | - Philipp Dworschak
- Center for Orthopedics and Traumatology, University Hospital Marburg, Marburg, Germany
| | - Christopher Bliemel
- Center for Orthopedics and Traumatology, University Hospital Marburg, Marburg, Germany
| | - Thomas Neri
- Department of Orthopaedic Surgery, University Hospital St Etienne, Saint-Étienne, France
| | | | | |
Collapse
|
41
|
Kutzner KP, Donner S, Loweg L, Rehbein P, Dargel J, Drees P, Pfeil J. Mid-term results of a new-generation calcar-guided short stem in THA: clinical and radiological 5-year follow-up of 216 cases. J Orthop Traumatol 2019; 20:31. [PMID: 31673809 PMCID: PMC6823459 DOI: 10.1186/s10195-019-0537-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 08/23/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND In recent years, a variety of short stems have been introduced. To date, mid- and long-term results of calcar-guided short-stem designs have been rarely available. MATERIALS AND METHODS Two hundred and sixteen calcar-guided short stems were included in combination with a cementless cup in a prospective study. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) as well as pain and satisfaction on visual analogue scale (VAS) were assessed during a median follow-up of 61.7 months. Standardised radiographs were analysed at predefined time points regarding radiological alterations such as bone resorption and remodelling, radiolucency, osteolysis and cortical hypertrophy using modified Gruen zones. RESULTS At mid-term follow-up, no revision surgery of the stem had to be performed in the whole collective. At 5 years, HHS was 97.8 (SD 4.7), satisfaction on VAS was 9.7 (SD 0.7), rest pain on VAS was 0.1 (SD 0.5), and load pain on VAS was 0.6 (SD 1.2). Compared to the 2-year results, femoral bone resorption increased significantly at the 5-year follow-up (3.9% versus 42.3%). Rate of femoral cortical hypertrophy remained stable, occurring in a total of 9 hips (4.5%). At the 5-year follow-up, 2 stems (1.0%) showed non-progressive radiolucent lines with a maximum width of 2 mm. Signs of osteolysis were not observed. Compared to the 2-year follow-up, no further subsidence was observed. CONCLUSIONS The rate of stem revision (0%) at the mid-term follow-up was remarkable and indicates the principle of using a calcar-guided short stem as being a safe procedure. However, signs of bone-remodelling, indicating some amount of stress-shielding, must be acknowledged at 5 years depending on stem alignment and type of anchorage. LEVEL OF EVIDENCE IV, Prospective observational study Trial registration German Clinical Trials Register, DRKS00012634, 07/07/2017 (retrospectively registered).
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany. .,Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany.
| | - Stefanie Donner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Lennard Loweg
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Joachim Pfeil
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| |
Collapse
|
42
|
Innmann MM, Weishorn J, Bruckner T, Streit MR, Walker T, Gotterbarm T, Merle C, Maier MW. Fifty-six percent of proximal femoral cortical hypertrophies 6 to 10 years after Total hip arthroplasty with a short Cementless curved hip stem - a cause for concern? BMC Musculoskelet Disord 2019; 20:261. [PMID: 31142303 PMCID: PMC6542080 DOI: 10.1186/s12891-019-2645-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 05/20/2019] [Indexed: 01/24/2023] Open
Abstract
Background Thigh pain and cortical hypertrophies (CH) have been reported in the short term for specific short hip stem designs. The purpose of the study was to investigate 1) the differences in clinical outcome, thigh pain and stem survival for patients with and without CHs and 2) to identify patient and surgery-related factors being associated with the development of CHs. Methods A consecutive series of 233 patients with 246 hips was included in the present retrospective diagnostic cohort study, who had received a total hip arthroplasty (THA) between December 2007 and 2009 with a cementless, curved, short hip stem (Fitmore, Zimmer, Warsaw, IN, USA). Clinical and radiographic follow-up, including the radiographic parameters for hip geometry reconstruction, were prospectively assessed 1, 3, and 6 to 10 years after surgery. Results Cortical hypertrophies were observed in 56% of the hips after a mean of 7.7 years, compared to 53% after 3.3 years being mostly located in Gruen zone 3 and 5. There was no significant difference for the Harris Hip Score and UCLA score for patients with and without CHs. Only one patient with a mild CH in Gruen zone 5 and extensive heterotopic ossifications around the neck of the stem reported thigh pain. The Kaplan Meier survival rate after 8.6 years was 99.6% (95%-CI; 97.1–99.9%) for stem revision due to aseptic loosening and no association with CHs could be detected. Postoperative increase in hip offset was the only risk factor being associated with the development of CHs in the regression model (ΔHO; OR 1.1 (1.0–1.2); p = 0.001). Conclusions The percentage of cortical hypertrophies remained almost constant in the mid-term compared to the short-term with the present cementless short hip stem design. The high percentage of cortical hypertrophies seems not be a cause for concern with this specific implant in the mid-term. Level of evidence Diagnostic Level IV
Collapse
Affiliation(s)
- Moritz M Innmann
- Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Johannes Weishorn
- Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Thomas Bruckner
- Institute of Medical Biometry and Informatics, University of Heidelberg, Im Neuenheimer Feld 130.3, 69120, Heidelberg, Germany
| | - Marcus R Streit
- Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Tilman Walker
- Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Tobias Gotterbarm
- Department of Orthopaedic and Trauma Surgery, Kepler University Hospital, Med Campus III Krankenhausstraße 9, 4021, Linz, Austria
| | - Christian Merle
- Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Michael W Maier
- Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| |
Collapse
|
43
|
Thalmann C, Kempter P, Stoffel K, Ziswiler T, Frigg A. Prospective 5-year study with 96 short curved Fitmore™ hip stems shows a high incidence of cortical hypertrophy with no clinical relevance. J Orthop Surg Res 2019; 14:156. [PMID: 31133027 PMCID: PMC6537407 DOI: 10.1186/s13018-019-1174-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Accepted: 04/29/2019] [Indexed: 12/20/2022] Open
Abstract
Background An increased occurrence of cortical hypertrophy (CH) was observed 1–2 years after implanting short curved Fitmore hip stems. There are no published data about either the clinical relevance or the progression of CH over the long term. Methods Ninety-six primary total hip arthroplasties were performed between 2008 and 2010 using the Fitmore hip stem. Clinical and radiological parameters were recorded preoperatively and at 1, 2, 3, and 5 year follow-up. Results CH appeared mainly on antero-posterior radiographs in Gruen Zones 2, 3, 5, and 6. After 1 year, the diameter was 10 ± 2 mm and remained constant thereafter. The CH rate after 1 year was 69% and after 5 years 71%. Subsidence after 1 year was 1.6 ± 1.55 mm and 1.93 ± 1.72 mm after 5 years. Cortical thinning was 46% after 1 year and 56% after 5 years, mainly in Gruen Zones 7 and 8. In the first year radiolucencies were found in 51% in all Gruen Zones, and in 20% after 5 years. Patient, implant, and surgical factors did not correlate with radiological outcomes except that larger stems had more CH. After 5 years, the Harris Hip Score had improved from 59 to 94 and the Oxford Hip Score from 22 to 41. Radiographic parameters, notably CH, were not associated with clinical outcomes except that cortical thinning correlated with lower outcome scores. Conclusions CH correlated neither with clinical outcome nor with patient, surgical or implant factors, except for a positive correlation with stem size. The Fitmore hip stems settled within the first year to a stable fixation and then remained almost unchanged. However, cortical thinning is common in Gruen Zone 7 and 8 meaning that there is stress-shielding.
Collapse
Affiliation(s)
- Caroline Thalmann
- Orthopedic Department, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland.,Orthopedic Department, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Patricia Kempter
- Orthopedic Department, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland.,Orthopedic Department, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Karl Stoffel
- Orthopedic Department, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland.,Orthopedic Department, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland.,Orthopedic Department, Kantonsspital Liestal, Rheinstrasse 26, 4410, Liestal, Switzerland
| | - Thea Ziswiler
- Orthopedic Department, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland.,Orthopedic Department, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Arno Frigg
- Orthopedic Department, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland. .,Orthopedic Department, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland. .,Private University of the Principality of Liechtenstein, Triesen, Liechtenstein.
| |
Collapse
|
44
|
Nam D, Salih R, Nahhas CR, Barrack RL, Nunley RM. Is a modular dual mobility acetabulum a viable option for the young, active total hip arthroplasty patient? Bone Joint J 2019; 101-B:365-371. [PMID: 30929489 DOI: 10.1302/0301-620x.101b4.bjj-2018-0834.r1] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed 'high-risk' for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study's purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. PATIENTS AND METHODS This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (sd 6.5)) were enrolled. All patients had a minimum of two years' clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis. RESULTS Mean Harris Hip Scores improved from 54.1 (sd 20.5) to 91.2 (sd 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (sd 0.03) preoperatively to 0.30 ug/l (sd 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (sd 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value. CONCLUSION Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365-371.
Collapse
Affiliation(s)
- D Nam
- Rush University Medical Center, Chicago Illinois, USA
| | - R Salih
- Washington University Orthopedics, Barnes Jewish Hospital, St. Louis, Missouri, USA
| | - C R Nahhas
- Rush University Medical Center, Chicago Illinois, USA
| | - R L Barrack
- Washington University Orthopedics, Barnes Jewish Hospital, St. Louis, Missouri, USA
| | - R M Nunley
- Washington University Orthopedics, Barnes Jewish Hospital, St. Louis, Missouri, USA
| |
Collapse
|
45
|
Age-related osseointegration of a short hip stem: a clinical and radiological 24 months follow-up. Arch Orthop Trauma Surg 2019; 139:405-410. [PMID: 30506094 DOI: 10.1007/s00402-018-3082-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Indexed: 01/30/2023]
Abstract
PURPOSE The purpose of this study was to examine potential differences between patients under and over 60 years who underwent a total short hip stem arthroplasty in a 24-month follow-up in a clinical setting. METHODS Sixty seven patients were included in this prospective study and divided in two groups. In the younger cohort 39 patients ≤ 59 years and in the older cohort 28 patients ≥ 60 years were included. Clinical and radiological examinations of the patients took place preoperatively, postoperatively and after 3, 6, 12 and 24 months. The Harris Hip Score (HHS) was raised as clinical examination. Changes of bone mass density (BMD), stress shielding, reactive lines, spot welds and sclerosing were examined as radiological analysis. RESULTS The HHS improved from 53.6 ± 8.2 preoperative to 93.2 ± 9.6 in the younger cohort and for the older cohort from 57.6 ± 14.8 to 94.1 ± 7.6 after 24 months. BMD growth was detectable in regions of interest (ROI) 3 and 6 for both groups. Different results between the cohorts could only be detected in ROIs 4 and 5. The older cohort showed a loss of BMD of 5.95% in ROI 4 and 3.17% in ROI 5 after 24 months, whereas the younger cohort showed no loss of BMD in both ROIs. CONCLUSIONS No significant differences or any influences of osseointegration and clinical outcome of the short hip stem for both groups were detectable. Lower losses (ROIs 1 and 2) and higher growths (ROIs 3, 4, 5) were discovered in younger patients and the HHS improved in both groups. Reasons for this result could be age, sex or the level of activity of the patients, but in both groups the short hip stem shows comparable results in clinical as well as in radiological examination. We conclude that the short hip stem seems to be an adequate treatment also for older patients.
Collapse
|
46
|
Heyland M, Checa S, Kendoff D, Duda GN. Anatomic grooved stem mitigates strain shielding compared to established total hip arthroplasty stem designs in finite-element models. Sci Rep 2019; 9:482. [PMID: 30679467 PMCID: PMC6345751 DOI: 10.1038/s41598-018-36503-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Accepted: 11/19/2018] [Indexed: 01/30/2023] Open
Abstract
Aseptic loosening remains a major problem for uncemented femoral components in primary total hip arthroplasty (THA). Ideally, bone adaptation after THA manifests minimally and local bone density reduction is widely avoided. Different design features may help to approximate initial, post-THA bone strain to levels pre-THA. Strain-shielding effects of different SP-CL stem design features are systematically analyzed and compared to CLS Spotorno and CORAIL using finite element models and physiological musculoskeletal loading conditions. All designs show substantial proximal strain-shielding: 50% reduced medial surface strain, 40–50% reduction at lateral surface, >120 µm/m root mean square error (RMSE) compared to intact bone in Gruen zone 1 and >60 µm/m RMSE in Gruen zones 2, 6, and 7. Geometrical changes (ribs, grooves, cross sections, stem length, anatomic curvature) have a considerable effect on strain-shielding; up to 20%. Combinations of reduced stem stiffness with larger proximal contact area (anatomically curved, grooves) lead to less strain-shielding compared to clinically established implant designs. We found that only the combination of a structurally flexible stem with anatomical curvature and grooves improves strain-shielding compared to other designs. The clinical implications in vivo of this initial strain-shielding difference are currently under evaluation in an ongoing clinical analysis.
Collapse
Affiliation(s)
- Mark Heyland
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
| | - Sara Checa
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | | | - Georg N Duda
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Berlin-Brandenburg Center for Regenerative Therapies, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
47
|
Meyer JS, Freitag T, Reichel H, Bieger R. Periprosthetic Bone Mineral Density Changes After Implantation of a Curved Bone Preserving Hip Stem Compared to a Standard Length Straight Stem: 5-Yr Results of a Prospective, Randomized DXA-Analysis. J Clin Densitom 2019; 22:96-103. [PMID: 30126775 DOI: 10.1016/j.jocd.2018.07.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 07/12/2018] [Accepted: 07/16/2018] [Indexed: 12/15/2022]
Abstract
INTRODUCTION The objective of this prospective, randomized study was to evaluate differences in periprosthetic bone mineral density changes in the proximal femur after implantation of a cementless bone preserving stem (Fitmore) compared to a cementless straight stem (CLS Spotorno). METHODOLOGY Periprosthetic bone mineral density was measured in 140 patients (aged 33-74 yr) before surgery, 7 d, 3, 12, and 60 mo postoperatively, using dual energy X-ray absorptiometry. The 1-yr results have already been published. The results of the first postoperative measurement served as the baseline value. Because of the different length of the 2 implants we used adapted Gruen zones to divide the periprosthetic bone in seven regions of interest with comparable length. Clinical results were recorded using the Western Ontario and McMaster Universities Arthritis Index and the Harris hip score. RESULTS Clinical findings showed comparable results in both groups at all follow-ups (p > 0.05). A total of 5 yr after surgery, the comparison of periprosthetic bone mineral density changes showed significant differences in regions of interests 3 (CLS -3.9% vs Fitmore -0.2%, p < 0.001) and 5 (CLS -3.6% vs Fitmore -1.3%, p = 0.0028) between both implants. CONCLUSION Despite the fact that no exclusive proximal load distribution could be observed, proximal periprosthetic bone loss in the proximal femur was less pronounced after implantation of the bone preserving stem than with the straight stem.
Collapse
Affiliation(s)
- Julian S Meyer
- Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany
| | - Tobias Freitag
- Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany
| | - Heiko Reichel
- Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany
| | - Ralf Bieger
- Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany.
| |
Collapse
|
48
|
Karachalios T, Palaiochorlidis E, Komnos G. Clinical relevance of bone remodelling around conventional and conservative (short-stem) total hip arthroplasty implants. Hip Int 2019; 29:4-6. [PMID: 30421637 DOI: 10.1177/1120700018810846] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Based on data from the existing literature, we can safely suggest that bone mineral changes around cementless and cemented conventional femoral stems, and conservative femoral stems, are not predictive of either satisfactory or unsatisfactory total hip arthroplasty long term clinical outcomes. Additionally, studies with a follow up shorter than 5-10 years are perhaps clinically irrelevant. These observations may be helpful in interpreting the existing literature.
Collapse
|
49
|
Nam D, Salih R, Barrack RL, Nunley RM. An evaluation of proximal femur bone density in young, active patients undergoing total hip arthroplasty at one year postoperatively. Hip Int 2019; 29:51-57. [PMID: 29726298 PMCID: PMC6305958 DOI: 10.1177/1120700018761152] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND: Prior investigations have shown a decrease in periprosthetic bone mineral density (BMD) of the calcar following total hip arthroplasty (THA). The purpose of this investigation was to study proximal femur BMD in a cohort of young, active patients following THA at 1 year postoperatively using a recently introduced stem design. METHODS: This was a prospective, IRB-approved investigation of patients with an age <65 years, BMI <35 kg/m2, and presymptomatic UCLA score of >6 undergoing a primary THA for a diagnosis of osteoarthritis. All patients received a titanium, proximally coated, tapered cementless femoral stem (ACCOLADE II, Stryker Inc, Mahwah, NJ, USA). Dual energy X-ray absorptiometry scans were performed at 6 weeks, 6 months, and 1 year postoperatively. Bone density was analyzed for 7 traditional Gruen zones with BMD ratios calculated for change in BMD compared with the baseline. RESULTS: 31 patients (mean age of 52.6 + 6.5 years, BMI of 27.9 + 3.9 kg/m2, and UCLA activity score of 7.3 + 1.9) were included. The mean BMD ratio decreased at the 6 months and 1 year interval in zones 1 and 2. However, the mean BMD ratio was maintained in Gruen zones 3 thru 7 with zone 7 (medial calcar) demonstrating 100% maintenance of the baseline BMD at 1 year. CONCLUSION: This study demonstrates the maintenance of medial calcar bone density at 1 year postoperatively in young, active patients undergoing THA. Further longitudinal analysis of this stem design is necessary to elucidate the significance of this finding.
Collapse
Affiliation(s)
- Denis Nam
- Rush University Medical Center, Department of Orthopedic Surgery, Chicago, IL, USA,Denis Nam, Rush University Medical Center, 1611 West Harrison St., Suite 300, Chicago, IL 60612, USA.
| | - Rondek Salih
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, MO, USA
| | - Robert L Barrack
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, MO, USA
| | - Ryan M Nunley
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, MO, USA
| |
Collapse
|
50
|
von Engelhardt LV, Breil-Wirth A, Kothny C, Seeger JB, Grasselli C, Jerosch J. Long-term results of an anatomically implanted hip arthroplasty with a short stem prosthesis (MiniHip TM). World J Orthop 2018; 9:210-219. [PMID: 30364820 PMCID: PMC6198291 DOI: 10.5312/wjo.v9.i10.210] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 06/17/2018] [Accepted: 06/28/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the clinical and radiological outcome nine and ten years after short-stemmed, bone preserving and anatomical hip arthroplasty with the MiniHipTM system.
METHODS In a prospective study, 186 patients underwent hip arthroplasty with a partial neck preserving short stem (MiniHipTM, Corin). Elderly patients were not excluded from this study, thus the mean age at the time of surgery was 59.3 years (range 32 to 82 years). Surgery and the follow-up assessments were performed at two Centers. Up until now, the mean follow-up was 112.5 ± 8.2 mo. The Oxford Hip Score (OHS) and the Hip Dysfunction Osteoarthritis and Outcome Score (HOOS) was assessed pre- and each year after surgery. The clinical follow-up was accompanied by standardized a.p. and axial radiological examinations. Periprosthetic lucencies, hypertrophies within the Gruen zones one to fourteen were assessed. A subsidence of the stem was investigated according to Morray and heterotopic ossifications were assessed according to Brooker.
RESULTS The OHS and HOOS improved from 18 ± 3.3 to 46 ± 2.0 and from 30 ± 8.3 to 95 ± 4.6 points, P < 0.001 respectively. There were no differences regarding age, etiology, friction pairings, etc., (P > 0.05). Two stems were revised due to a symptomatic subsidence four and twelve months postoperatively. Thus, the survivorship for aseptic loosening at nine to ten years was 98.66%. Including one stem revision due to a symptomatic exostosis, bursitis and thigh pain as well as one revision because of a septic stem loosening, the overall survival for the stem with revision for any reason was 97.32%. Besides one asymptomatic patient, radiological signs of a proximal stress-shielding, such as bone resorptions within the proximal Gruen zones, were not noticed. Findings suggesting a distal loading, e.g., bony hypertrophies or bone appositions of more than 2 mm, were also not detected.
CONCLUSION Regarding these first long-term results on the MiniHipTM, the implant performed exceedingly well with a high rate of survivorship for aseptic loosening. Our radiological results within the Gruen zones support the design rationale of the Minihip to provide a reliable metaphyseal anchoring with the expected proximal, more physiological load transfer. This might minimize or exclude a stress shielding which might be associated with thigh pain, proximal bone loss and an increased risk of aseptic loosening. The MiniHipTM is a reliable partial-neck retaining prosthesis with good a clinical long-term outcome in younger as well as elderly patients.
Collapse
Affiliation(s)
- Lars V von Engelhardt
- Faculty of Health, University of Witten/Herdecke, Witten 58448, Germany
- Department of Trauma Surgery Orthopedics and Sports Medicine, Katholisches Karl-Leisner Klinikum, Kleve 47533, Germany
| | - Andreas Breil-Wirth
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
| | | | - Jörn Bengt Seeger
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Giessen 35392, Germany
| | - Christian Grasselli
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
- Department of Orthopaedics and Traumatology, Waldburg-Zeil Clinic Tettnang, Tettnang 88069, Germany
| | - Joerg Jerosch
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
| |
Collapse
|