1
|
Huang S, He S, Kenmegne GR, Yin Y, Yu Y, Fang Y. Anterior subcutaneous internal fixator (INFIX) versus plate fixation for anterior ring injury in Tile C pelvic fractures: a retrospective study. BMC Surg 2025; 25:110. [PMID: 40119294 PMCID: PMC11927202 DOI: 10.1186/s12893-025-02844-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 03/13/2025] [Indexed: 03/24/2025] Open
Abstract
OBJECTIVES . The purpose of this study was to compare the reduction effect and clinical outcomes of anterior subcutaneous internal fixation (INFIX) and steel plate-screw internal fixation in the treatment of anterior ring injury in Tile C pelvic fractures. METHODS . In this retrospective study, the clinical outcomes of 46 patients treated using INFIX and 44 patients treated with steel plate-screw internal fixation were analyzed and compared. All patients underwent anterior and posterior fixation. The Matta imaging scoring system was used to evaluate the postoperative reduction accuracy; the Majeed scoring system was applied to obtain functional outcomes in clinical follow-up. All potential complications were identified and evaluated accordingly. RESULTS Both groups of patients were followed up for a period of 13-36 months, with an average of 27 months. The procedure time and blood loss in the INFIX group were significantly lower than those in the plate group(t = - 2.327, P = 0.023;t = - 4.053, P = 0.000; there was no statistically significant difference in the Majeed score and Matta score between the two groups after surgery (P > 0.05). CONCLUSIONS . INFIX treatment for anterior ring injury in Tile C pelvic fractures can achieve good therapeutic effects. Compared to internal fixation with plates and screws, it has advantages such as shorter surgical time and less blood loss. INFIX may be more suitable for obese patients, young women of childbearing age, or patients with urinary system injuries.
Collapse
Affiliation(s)
- Shenbo Huang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Shuai He
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Guy Romeo Kenmegne
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Yijie Yin
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - You Yu
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Yue Fang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China.
| |
Collapse
|
2
|
Su YC, Hsu YH, Chou YC, Chen IJ, Lai CY, Yu YH. Iatrogenic nerve injury following pelvic ring injury: a network meta-analysis. Int J Surg 2025; 111:2697-2707. [PMID: 39903523 DOI: 10.1097/js9.0000000000002272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Accepted: 12/20/2024] [Indexed: 02/06/2025]
Abstract
BACKGROUND Pelvic ring injuries are common in multi-trauma patients and can be life-threatening, necessitating prompt surgical intervention to improve outcomes. However, surgery can lead to complications such as iatrogenic nerve injury. This network meta-analysis aimed to improve outcomes in multi-trauma patients with pelvic ring injuries by evaluating the incidence of iatrogenic nerve injuries, identifying vulnerable nerves, and comparing different fixation methods. MATERIALS AND METHODS A systematic search of MEDLINE, EMBASE, and Scopus from inception to 5 December 2023 revealed 29 comparative studies on the incidence of iatrogenic nerve injury in 1561 adult patients with pelvic ring injuries. Data were extracted on study and patient characteristics, iatrogenic nerve injury incidences, and specific nerve injuries. A random-effects model assessed treatment effects, with subgroup analysis and meta-regression. The main outcomes included odds ratios (ORs) and confidence intervals (CIs) for iatrogenic nerve injuries. RESULTS Compared with closed reduction internal fixation, robotic-assisted techniques had the highest, and open reduction internal fixation had the lowest ORs for iatrogenic nerve injuries. The robotic-assisted approach ranked best with an OR of 0.22 (95% CI: 0.02-2.16), while closed reduction internal fixation with the anterior approach (OR: 0.71; 95% CI: 0.21-2.48) and open reduction internal fixation with the anterior approach performed the worst. The lateral femoral cutaneous nerve was injured in all open reduction internal fixation with anterior approach procedures and in 66.7% of open reduction internal fixation with posterior approach procedures. Meta-regression showed a significantly lower OR for iatrogenic nerve injuries in patients aged >41.4 years in the open reduction internal fixation with the anterior approach group (OR: 0.02; 95% CI: 0.001-0.63; P = 0.026) compared with younger patients. CONCLUSION The robotic-assisted technique may result in the fewest iatrogenic nerve injuries during the treatment of pelvic ring injuries. The posterior approach may also reduce the risk of iatrogenic nerve injuries.
Collapse
Affiliation(s)
- Yu-Cheng Su
- Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan
| | - Yung-Heng Hsu
- Department of Orthopedic Surgery, Musculoskeletal Research Center, Chang Gung Memorial Hospital and Chang Gung University, Tao-Yuan, Taiwan
| | - Ying-Chao Chou
- Department of Orthopedic Surgery, Musculoskeletal Research Center, Chang Gung Memorial Hospital and Chang Gung University, Tao-Yuan, Taiwan
| | - I-Jung Chen
- Department of Orthopedic Surgery, Musculoskeletal Research Center, Chang Gung Memorial Hospital and Chang Gung University, Tao-Yuan, Taiwan
| | - Chih-Yang Lai
- Department of Orthopedic Surgery, Musculoskeletal Research Center, Chang Gung Memorial Hospital and Chang Gung University, Tao-Yuan, Taiwan
| | - Yi-Hsun Yu
- Department of Orthopedic Surgery, Musculoskeletal Research Center, Chang Gung Memorial Hospital and Chang Gung University, Tao-Yuan, Taiwan
| |
Collapse
|
3
|
Gänsslen A, Lindahl J, Krappinger D, Lindtner RA, Staresinic M. Outcome of pelvic ring injuries. Arch Orthop Trauma Surg 2024; 145:47. [PMID: 39680172 PMCID: PMC11649792 DOI: 10.1007/s00402-024-05606-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Accepted: 11/10/2024] [Indexed: 12/17/2024]
Abstract
Outcome evaluation is of major importance to provide data to analyze the value of the chosen treatment concept. Despite an increasing effort of analyzing outcome after treatment of different pelvic ring injuries, a mixture of different outcome parameters is in use. The Majeed score is most frequently used for mid- to long-term evaluation and the quality of life is analyzed using the SF-36 score. The lack in nearly all studies is that different treatment concepts are used, and only selected evaluation parameters are reported. Until today, no well-accepted standardized measurement instruments are available to analyze the clinical and radiological results after pelvic ring injuries. Overall, stability-based long-term sequelae can be expected with increasing complaints from stable type A injuries to completely unstable type C injuries. Beside a fracture-type specific treatment, concomitant injuries of other injury regions and associated local pelvic injuries (complex pelvic trauma) seem to additionally influence the results. Results of treatment of specific fracture types are sparse as a wide range of different injury types and different treatment concepts are analyzed within these analyses. A sufficient pelvic outcome instrument which addresses relevant pelvic outcome parameters is still missing. Thus, future evaluation of long-term results after pelvic ring. injuries should include prospective, multicenter outcome studies with comparable parameters.
Collapse
Affiliation(s)
- Axel Gänsslen
- Department of Trauma Surgery, Hannover Medical School, Hanover, Germany.
- Johannes Wesling Klinikum Minden, Minden, Germany.
| | - Jan Lindahl
- Helsinki University Hospital, Helsinki, Finland
| | | | | | | |
Collapse
|
4
|
Xia Z, Zhang Y, Zhang X, Li W, Lv Y, Qi X, Wang Y, Zhu Z. Radiographic and clinical evaluation of external pedicle screw fixation as a definitive solution for selective acetabular fractures: a retrospective analysis. BMC Musculoskelet Disord 2024; 25:947. [PMID: 39580410 PMCID: PMC11585101 DOI: 10.1186/s12891-024-08049-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Accepted: 11/08/2024] [Indexed: 11/25/2024] Open
Abstract
BACKGROUND Acetabular fractures typically require open surgery to restore hip joint function. Openness may lead to serious tissue damage, increased bleeding, and the risk of nerve and vascular damage. Minimally invasive closed reduction or percutaneous fixation aims to minimize additional harm to patients and provide reliable fixation to promote fracture recovery and functional rehabilitation. This study aimed to assess the radiographic and clinical effectiveness of pedicle screw external fixation as a definitive treatment approach for selective acetabular fractures. METHODS The present study enrolled 43 patients with acetabular fractures who were categorized into three groups based on their definitive treatment plans: pedicle screw external fixation group, traditional external fixation stent fixation group, and open reduction internal fixation group, comparing the operative duration and the time required for fracture healing. Fracture reduction was evaluated using the Tornetta and Matta grading system, and postoperative clinical outcomes were analyzed using the Majeed score. Analyze three surgical methods by comparing clinical indicators and prognostic references. RESULTS Among the 43 patients, there were 12 cases in the pedicle screw external fixation group, 14 cases in the traditional external fixation stent fixation group, and 17 cases in the open reduction internal fixation group. There were no significant differences in age, gender, injury mechanism, Injury Severity Score (ISS), or other demographic factors among the three groups. The reduction of fractures with internal fixation was significantly better than that with external fixation(p = 0.032). Operative duration and quality of reduction did not significantly differ between the pedicle screw external fixation group and the traditional external fixation stent fixation group. However, the pedicle screw external fixation group exhibited distinct advantages in postoperative quality of life (p = 0.041) and a lower incidence of loose fixing screws compared to the traditional external fixation stent fixation group. CONCLUSION Compared to traditional external fixation stent fixation, pedicle screw external fixation represents a superior definitive treatment option for acetabular fractures due to its stability and improved patient quality of life.
Collapse
Affiliation(s)
- Zhen Xia
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
| | - Yazhong Zhang
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
| | - Xu Zhang
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
- Graduate school of Xuzhou Medical University, Xuzhou, Jiangsu, 221000, China
| | - Wenbo Li
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
| | - Yongxiang Lv
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
| | - Xiangyu Qi
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
- Graduate school of Xuzhou Medical University, Xuzhou, Jiangsu, 221000, China
| | - Yunqing Wang
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China
| | - Ziqiang Zhu
- Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, No 32 Meijian Road, Xuzhou, Jiangsu, 221000, China.
| |
Collapse
|
5
|
Ping Z. Percutaneous hollow nail internal fixation treatment for fractures of the pubic symphysis and its adjacent areas. Front Surg 2024; 11:1400834. [PMID: 39534695 PMCID: PMC11554617 DOI: 10.3389/fsurg.2024.1400834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 10/07/2024] [Indexed: 11/16/2024] Open
Abstract
Purpose To explore the percutaneous minimally invasive treatment of pubic symphysis and its adjacent fractures. Method Since May 2021, 13 cases of fractures involving the pubic symphysis and its adjacent parts were treated with x-ray fluoroscopic localization and percutaneous cannulated screw fixation across the symphysis pubis, the guide pin pierced the symphysis pubis and the fracture end and stopped at the inner edge of the acetabulum. Visual analogue scale (VAS) was used to evaluate the effect of the operation, and the patients were followed up. Result The screw insertion operation time was 25-40 min, with an average of 31.45 min; The number of perspectives is 20-40, with an average of 28.75. The average intraoperative blood loss was 10 ml, and there were no puncture complications such as nerve or vascular damage. The initial stability of the fractured end of the patient after surgery was good. The VAS score decreased from preoperative 8-10 points to postoperative 1-2 points (average of 1.5 points). The follow-up time was 3-25 months, with an average of 8.5 months. At the last follow-up, the excellent and good rate of pelvic function according to Majeed pelvic function scoring system was 100%. One patient had screws removed 1.5 years after surgery, while the remaining twelve patients did not have screws removed. All patients did not experience any discomfort symptoms caused by pubic symphysis fixation. Conclusion Percutaneous hollow nail internal fixation is an effective method for treating fractures of the pubic symphysis and its adjacent parts.
Collapse
Affiliation(s)
- Zhang Ping
- Department of Orthopedics, Zibo Municipal Hospital, Zibo, China
| |
Collapse
|
6
|
Yin Y, Jiang J, Kenmegne GR, Fang Y. Lower abdominal cyst complicated with suspected infection following INFIX internal fixation for pelvic fracture: a report of two rare cases. BMC Musculoskelet Disord 2024; 25:620. [PMID: 39095720 PMCID: PMC11297756 DOI: 10.1186/s12891-024-07747-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 07/29/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND The Internal Fixator (INFIX) is a popular method, known for its minimal invasiveness and short operation time, for treating anterior pelvic ring fractures. Studies have shown that postoperative complications may occur, including anterolateral femoral cutaneous nerve injury, the femoral nerve paralysis, and delayed fracture healing. These complications are believed to be related to surgical stimulation, an excessively long lateral end of the connecting rod, a small distance between the screw and bone surface, insufficient pre-bending of the connecting rod, and difficulties in fracture reduction. CASE PRESENTATION We report two unique cases of lower abdominal pseudocyst complicated with suspected infection after INFIX treatment of pelvic fractures at our trauma center. Following surgical removal of the internal fixation, resolution of the cysts was observed in both patients, and subsequent postoperative follow-up revealed the absence of any residual sequelae. These cases have not been reported in previous literature reviews. DISCUSSION The lower abdominal cysts, potentially arising from the dead space created during intraoperative placement of the INFIX rod, may increase infection risk. The etiology remains uncertain, despite the presence of abnormal inflammation markers in both cases, and staphylococcus aureus found in one. These cysts were confined to the lower abdomen, not involving the internal fixation, and hence, only the INFIX was removed. Postoperative oral cefazolin treatment was successful, with resolved pseudocysts and no subsequent discomfort. CONCLUSION We report two unprecedented cases of post-INFIX abdominal cysts, with a suspected link to intraoperative dead space. Despite uncertain etiology, successful management involved INFIX removal and oral cefixime therapy. These findings necessitate further exploration into the causes and management of such complications.
Collapse
Affiliation(s)
- Yijie Yin
- Department of Orthopedics Surgery, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu, China
- Trauma Center, West China Hospital of Sichuan University, Chengdu, China
| | - JiaBao Jiang
- Department of Orthopedics Surgery, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu, China
- Trauma Center, West China Hospital of Sichuan University, Chengdu, China
| | - Guy Romeo Kenmegne
- Department of Orthopedics Surgery, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu, China
- Trauma Center, West China Hospital of Sichuan University, Chengdu, China
| | - Yue Fang
- Department of Orthopedics Surgery, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu, China.
- Trauma Center, West China Hospital of Sichuan University, Chengdu, China.
| |
Collapse
|
7
|
Hiyama A, Ukai T, Tanaka T, Watanabe M. Advancements in pelvic ring fracture surgery: Assessing INFIX screw placement accuracy with CT navigation. Injury 2024; 55:111600. [PMID: 38759488 DOI: 10.1016/j.injury.2024.111600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/01/2024] [Accepted: 05/03/2024] [Indexed: 05/19/2024]
Abstract
The management of unstable pelvic ring fractures, typically resulting from high-energy trauma, presents a significant clinical challenge due to the complexity of injuries. While effective in many cases, the traditional stabilization methods are fraught with various complications that can significantly impact patient recovery and quality of life (QOL). This study aims to evaluate the efficacy and precision of the anterior subcutaneous internal fixator (INFIX) technique when used with intraoperative computed tomography (CT) navigation, a novel approach intended to mitigate the limitations of conventional treatment modalities. Our retrospective case series encompasses 43 patients who sustained traumatic pelvic injuries and were subsequently treated with the INFIX technique from December 2020 to January 2024. The focus of this analysis was to assess the accuracy of INFIX screw placement facilitated by intraoperative CT navigation. A total of 81 INFIX screws were inserted, and our study findings reveal a high level of precision in screw placement, with only one screw deviating, resulting in an inaccuracy rate of merely 1.2 %. This highlights the significant advantage provided by intraoperative CT navigation. The high level of accuracy not only enhances the stability of the pelvic fixation but also substantially reduces the risk of complications commonly associated with screw misplacement, such as abdominal damage, vascular injury, and issues related to incorrect hardware positioning. In conclusion, the integration of the INFIX technique with intraoperative CT navigation in the treatment of unstable pelvic ring fractures represents a significant advancement in orthopedic trauma surgery. This study provides compelling evidence supporting the efficacy and precision of this approach, suggesting its potential as a superior alternative to traditional fixation methods. Further research, ideally through prospective studies involving larger patient cohorts, is needed to validate these findings and explore the long-term implications of this technique on patient recovery and QOL.
Collapse
Affiliation(s)
- Akihiko Hiyama
- Department of Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara, Kanagawa, 259-1193, Japan.
| | - Taku Ukai
- Department of Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara, Kanagawa, 259-1193, Japan
| | - Tatsumi Tanaka
- Department of Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara, Kanagawa, 259-1193, Japan
| | - Masahiko Watanabe
- Department of Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara, Kanagawa, 259-1193, Japan
| |
Collapse
|
8
|
Xia W, Jiang H, Tao E, Ye J, Wang F, Wang X, Cai L, Feng Y. Comparison of ESIN and other minimally invasive techniques for anterior pelvic ring injury: a finite element analysis and case-control study. Int J Surg 2024; 110:2636-2648. [PMID: 38320104 DOI: 10.1097/js9.0000000000001137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 01/25/2024] [Indexed: 02/08/2024]
Abstract
OBJECT A novel technique, percutaneous elastic stable intramedullary nail fixation (ESIN), proposed by our team for the treatment of anterior pelvic ring injury. Finite element analysis and retrospective case-control study were used to compare biomechanical properties and clinical outcomes between ESIN and other techniques. METHODS Four groups of finite element models of pelvic anterior ring injury were simulated, including ESIN (model A), retrograde transpubic screw fixation (RTSF, model B), subcutaneous internal fixator (model C), and external fixator (model D), and a vertical downward load of 500 N was applied to the S1 vertebral endplate. Stress and displacement distributions of intact pelvis, displacement distributions of pubic fracture fragments, and stress distributions of fixation devices were analysed. Then 31 patients with anterior pelvic ring injury (15 in the ESIN group and 16 in the RTSF group) were reviewed. Clinical outcomes were evaluated at the final follow-up. Postoperative complications were also recorded. RESULTS Under 500N loading, the intact stability of the pelvis was compared as follows: model B (20.58 mm, 121.82 MPa), model A (20.80 mm, 129.97 MPa), model C (22.02 mm, 141.70 MPa), and model D (22.57 mm, 147.06 MPa). The regional stability of superior pubic ramus was compared as follows: model B (9.48 mm), model A (10.16 mm), model C (10.52 mm), and model D (10.76 mm). All 31 patients received follow-up at least 12 months postsurgery (range 12-20 months). Age, sex, injury mechanism, fracture type, time between the injury and operation, American Society of Anesthesiologists score, intraoperative blood loss, hospital stay, follow-up period, time to union, and Majeed scores did not differ significantly between the two groups ( P >0.05). However, the differences in the duration of unilateral surgery, unilateral intraoperative fluoroscopy and one-time success rate were significant ( P <0.05). CONCLUSIONS With sufficient biomechanical stability and minimally invasive advantage, the percutaneous technique using ESIN can be used to successfully treat anterior pelvic ring injuries. In addition, advantages over RTSF include a shorter duration of surgery, reduced requirement for intraoperative fluoroscopy, and a higher one-time success rate. ESIN therefore constitutes a good alternative to RTSF.
Collapse
Affiliation(s)
- Weijie Xia
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Hongyi Jiang
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Endong Tao
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Jianjun Ye
- West China Hospital of Sichuan University, Chengdu, People's Republic of China
| | - Fulin Wang
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Xianyu Wang
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Leyi Cai
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Yongzeng Feng
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| |
Collapse
|
9
|
Zhao P, Li R, Liu L, Wang X, Chen X, Guan J, Wu M. Clinical study of modified INFIX combined with sacroiliac joint screws for pelvic instable injuries. BMC Surg 2023; 23:350. [PMID: 37974146 PMCID: PMC10655463 DOI: 10.1186/s12893-023-02205-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 09/23/2023] [Indexed: 11/19/2023] Open
Abstract
OBJECTIVE The INFIX technique is becoming one of the most commonly performed surgical procedures for anterior pelvic ring instability injuries. The purpose of this article is to compare the clinical outcomes of modified anterior subcutaneous internal fixation (M-INFIX) with conventional anterior subcutaneous internal fixation (C-INFIX) for anterior pelvic ring instability injuries. PATIENTS AND METHODS A retrospective analysis of 36 cases of unstable pelvic injuries treated operatively at our institution, 20 of which were treated with C-INFIX and 16 with M-INFIX. Data collected included age, gender, ISS score, fracture typing, operative time, operative bleeding, postoperative complications, fracture healing time, Matta score, Majeed score, and follow-up time. Statistical sub-folding of each variable between the two groups was performed. RESULTS There was no statistical difference between the C-INFIX and M-INFIX groups in terms of age, gender, ISS (Injury Severity Score), follow-up time, fracture typing, fracture healing time, and Majeed score (P > 0.05). the M-INFIX had a significantly lower incidence of postoperative complications than the C-INFIX group, especially in the incidence of Lateral femoral cutaneous nerve (LFCN) injury (P < 0.05). In contrast, the M-INFIX group had statistically higher operative time, intraoperative bleeding, and Matta score than the C-INFIX group (P < 0.05). CONCLUSION This study was based on a modified application of the surgical experience with C-INFIX and showed better clinical outcomes in terms of complication rates and quality of repositioning than the conventional surgical approach. These findings indicate that further analytical studies of this study would be valuable.
Collapse
Affiliation(s)
- Peishuai Zhao
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Renjie Li
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Leyu Liu
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Xiaopan Wang
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Xiaotian Chen
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Jianzhong Guan
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China.
| | - Min Wu
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China.
| |
Collapse
|
10
|
Walters S, Cuthbert R, Ward J, Arshad H, Culpan P, Perkins Z, Tai N, Bates P. Causes and associations with mortality in patients with pelvic ring injuries with haemorrhagic shock. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023; 33:2971-2979. [PMID: 36922411 DOI: 10.1007/s00590-023-03516-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 03/02/2023] [Indexed: 03/18/2023]
Abstract
BACKGROUND High energy pelvic ring injuries are associated with significant morbidity and mortality and can be accompanied by haemorrhagic shock following associated vascular injury. This study evaluated the causes and predictors of mortality in haemodynamically unstable pelvic fractures. METHODS This retrospective observational study at a Major Trauma Centre reviewed 938 consecutive adult patients (≥ 18yrs) with pelvic ring injuries between December 2014 and November 2018. Patients with features of haemorrhagic shock were included, defined as: arrival Systolic BP < 90 mmHg, Base Deficit ≥ 6.0 mmol/l, or transfusion of ≥ 4 units of packed red blood cells within 24 h. RESULTS Of the 102 patients included, all sustained injuries from high energy trauma, and 47.1% underwent a haemorrhage control intervention (Resuscitative Endovascular Balloon Occlusion of the Aorta-REBOA, Interventional Radiology-IR, or Laparotomy). These were more often required following vertical shear injuries (OR 10.7, p = 0.036). Overall, 33 patients (32.4%) died; 16 due to a head injury, and only 2 directly from acute pelvic exsanguination (6.1%). Multivariable logistic regression demonstrated that increasing age, Injury Severity Score, Abbreviated Injury Scale (AIS) Head ≥ 3 and open pelvic fracture were all independent predictors of mortality, and IR was associated with reduced mortality. Lateral Compression III (LC3) injuries were associated with mortality due to multiple organ dysfunction syndrome (MODS). CONCLUSION Haemodynamically unstable patients with pelvic ring injuries have a high mortality rate, but death is usually attributed to other injuries or later complications, and not from acute exsanguination. This reflects improvements in resuscitative care, transfusion protocols, and haemorrhage control techniques.
Collapse
Affiliation(s)
- Samuel Walters
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK.
| | - Rory Cuthbert
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| | - Jonathan Ward
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| | - Homa Arshad
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| | - Paul Culpan
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| | - Zane Perkins
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| | - Nigel Tai
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| | - Peter Bates
- Royal London Hospital, Whitechapel Road, Whitechapel, London, E1 1BB, UK
| |
Collapse
|
11
|
Baumann F, Pagano S, Alt V, Freigang V. Bony Sacral Volume after Sacro-Iliac Screw Fixation of Pelvic Fractures Is Dependent on Reduction of the Anterior Pelvic Ring. J Clin Med 2023; 12:4169. [PMID: 37373862 PMCID: PMC10299215 DOI: 10.3390/jcm12124169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 06/13/2023] [Accepted: 06/15/2023] [Indexed: 06/29/2023] Open
Abstract
Pelvic ring injuries are uncommon but serious injuries. Percutaneous sacro-iliac screw fixation (SSF) is the standard treatment for posterior stabilization of pelvic fractures. Compression forces of the SSF might cause deformity of the sacrum and the pelvic ring. The aim of this radio-volumetric study is to evaluate the morphometry of the sacrum and pelvic ring in SSF for posterior pelvic fractures. (1) Methods: We conducted a radio-volumetric study measuring the bony sacral volume before and after SSF for a pelvic fracture based on a three-dimensional reconstruction of the pre- and postoperative computed tomography scan of 19 patients with a C-type pelvic fracture. In addition to the bony sacral volume, we assessed the pelvic deformity and the load bearing axis. We compared the results of patients without anterior stabilization (Group A) to patients who had additional ORIF of the anterior pelvic ring. (2) Results: Median age of the patients was 41.2 years (±17.8). All patients received percutaneous SSF with partially threaded 7.3 mm screws. The sacral volume decreased from 202.9 to 194.3 cm3 in group A (non-operative treatment anterior, n = 10) and an increase of sacral volume from 229.8 to 250.4 cm3 in group B (anterior ORIF; n = 9). Evaluation of the pelvic deformity also reflected this trend by a decrease of the ipsilateral load-bearing angle in group A (37.0° to 36.4°) and an increase of this angle in group B (36.3 to 39.9°). (3) Conclusions: Bony sacral volume and pelvic deformity after sacro-iliac screw fixation in pelvic fractures depend on treatment of the anterior pelvic ring. Reduction and fixation of the anterior fracture shows an increase of the bony sacral volume and the load bearing angle leading to a closer to normal reconstruction of the pelvic anatomy.
Collapse
Affiliation(s)
- Florian Baumann
- Department of Trauma Surgery, University Medical Centre Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (V.A.)
| | | | | | | |
Collapse
|
12
|
Zhao C, Zhu G, Wang Y, Wu X. TiRobot‑assisted versus conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation for pelvic ring injuries: a meta‑analysis. J Orthop Surg Res 2022; 17:525. [PMID: 36471345 PMCID: PMC9721051 DOI: 10.1186/s13018-022-03420-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 11/24/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND The TiRobot is the only robot that has been reported in the literature for posterior pelvic injuries. We aim to compare TiRobot-assisted pelvic screw fixation with the conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation. METHODS We conducted a meta-analysis to identify studies involving TiRobot‑assisted versus conventional percutaneous sacroiliac screw fixation for pelvic ring injuries in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and WanFang database, up to April 2022. The following keywords were used: "TiRobot," "robot," "robotic," "pelvic fracture," "screw fixation," "percutaneous," and "pelvic ring injury." Pooled effects of this meta-analysis were calculated using STATA SE version 15.0. RESULTS Compared with conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation, TiRobot will result in less radiation exposure time of screw implantation (P = 0.000), less frequency of intraoperative fluoroscopy (P = 0.000), fewer guide wire attempts (P = 0.000), less intraoperative blood loss (P = 0.005), better screw accuracy (P = 0.011), better Majeed score (P = 0.031), and higher overall excellent and good rates of Majeed score (P = 0.018). However, there were no significant differences in terms of operative time (P = 0.055), fracture healing time (P = 0.365), and overall excellent and good rate of reduction accuracy (P = 0.426) between the two groups. CONCLUSION TiRobot-assisted fixation has less intraoperative fluoroscopy and intraoperative blood loss, superior screw accuracy, and Majeed score compared with conventional percutaneous sacroiliac screw fixation. TiRobot has no significant effect on operative time, fracture healing time, and reduction accuracy. Given the relevant possible biases in our meta-analysis, we required more adequately powered and better-designed RCT studies with long-term follow-up to reach a firmer conclusion.
Collapse
Affiliation(s)
- Chunpeng Zhao
- Department of Orthopedics and Traumatology, Beijing Jishuitan Hospital, Beijing, 100035 China
| | - Gang Zhu
- Rossum Robot Co., Ltd., Beijing, 100083 China
| | - Yu Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083 China
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100083 China
| | - Xinbao Wu
- Department of Orthopedics and Traumatology, Beijing Jishuitan Hospital, Beijing, 100035 China
| |
Collapse
|
13
|
Chen H, Ding C, Liu Y, Kong Z, Chang S, Huang F, Li H, Guo Q, Yang Y, Zhong H, Yang S. A clinical and biomechanical comparison of INFIX plus single versus double sacroiliac screw fixation for unstable pelvic ring injury. J Orthop Surg Res 2022; 17:285. [PMID: 35597957 PMCID: PMC9124380 DOI: 10.1186/s13018-022-03133-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Accepted: 04/12/2022] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND The aim of this study is to compare the clinical and biomechanical outcome of INFIX plus single with two sacroiliac screw fixation for unstable pelvic fractures of Type C. METHODS Sixteen cadavers were randomly subjected to INFIX plus single or double sacroiliac screw fixations and then mounted onto the ElectroForce loading machine under different vertical loads. To investigate the clinical outcomes of the two techniques, nineteen patients were retrospectively analyzed. The main outcome measures were postoperative radiographic reduction grading (using the Tornetta and Matta grading system), functional outcome (using the Majeed scoring system), and incidence of complications. RESULTS In the biomechanical study, INFIX plus double sacroiliac screw fixation showed better biomechanical stability than fixation with a single sacroiliac screw (p < 0.05). In our clinical case series, all 19 patients had bony union 6 months after the operation. INFIX plus double sacroiliac screw fixation also demonstrated a better functional outcome and a higher radiographic satisfactory rate than INFIX plus single sacroiliac screw fixation (79.25 ± 5.47; 91.33 ± 4.97; p < 0.05), (77.78% vs. 60%; p = 0.05). One patient in INFIX plus single-screw fixation group had screw loosening at 6-month follow-up postoperatively. One case in each group suffered heterotopic ossification and the lateral femoral cutaneous nerve paralysis, and one patient suffered from infection. CONCLUSION INFIX plus double sacroiliac screw fixation demonstrated more stability in cadaveric biomechanical analysis and better clinical outcomes than INFIX plus single sacroiliac screw fixation.
Collapse
Affiliation(s)
- Hongfen Chen
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Chao Ding
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Yongqiang Liu
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Zhen Kong
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Siling Chang
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Feng Huang
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Heng Li
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Qingxiang Guo
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Yuehua Yang
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
- Department of Orthopedics, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200080 People’s Republic of China
| | - Hua Zhong
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| | - Shaozheng Yang
- Department of Orthopaedics, The Fifth Affiliated Hospital, Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, 510900 People’s Republic of China
| |
Collapse
|
14
|
Qi H, Geng X, Yu X, Chen W, Jia J, Tian W. Posterior INFIX for Treating Unilateral Unstable Sacral Fractures. Orthop Surg 2022; 14:750-757. [PMID: 35343061 PMCID: PMC9002066 DOI: 10.1111/os.13251] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 01/29/2022] [Accepted: 02/18/2022] [Indexed: 11/30/2022] Open
Abstract
Objective To evaluate the clinical outcomes of the treatment of unilateral unstable sacral fractures by fixation with the posterior INFIX (posterior pelvic ring screw‐rod internal fxation). Methods Data of 60 patients with unilateral unstable sacral fractures who underwent surgery from March 2013 to March 2020 were retrospectively analyzed according to the selection criteria. All patients were associated with anterior pelvic ring injuries, and the operations were performed by the same team of surgeons. According to the different types of internal fixation, the patients were divided into two groups, which both included 30 patients: the posterior INFIX group and iliosacral screw fixation group. The demographic and clinical data of the two patient groups, such as age, sex, sacral fracture types based on the Denis classification, operation time, amount of intraoperative bleeding, intraoperative fluoros copy time, Majeed pelvic score at final follow‐up, and quality of fracture reduction based on Mears and Velyvis's imaging classification criteria were collected by the same researcher and compared statistically. Results All patients were continuously followed up for 23.17 ± 3.34 months (range, 12 to 46 months). All sacral fractures healed with an average healing time of 9.3 ± 2.24 months (range, 6 to 18 months). None of the patients had re‐displacement of the fracture or fixation failure. Compared to the iliosacral screw group, the posterior INFIX group patients had more intraoperative bleeding (t = 3.59, P < 0.001), shorter operation time (t = 4.49, P < 0.001), and shorter intraoperative fluoroscopy time (t = 6.26, P < 0.001). There were no statistical differences between the two groups in terms of age, sex, fracture type, Majeed score, and quality of fracture reduction (P > 0.05). In the posterior INFIX group, one patient had a superficial wound infection and one patient complained of discomfort due to a prominent fixation. In the iliosacral screw fixation group, one patient had intraoperative iatrogenic S1 nerve injury and vessel injury. The posterior INFIX fixation was a simpler manipulation with higher safety, shorter time of operation and intraoperative fluoroscopy, and similar clinical outcomes compared to iliosacral screw fixation. Conclusion For the treatment of unilateral unstable sacral fractures, the posterior INFIX fixation can be recommended in clinic application.
Collapse
Affiliation(s)
- Haotian Qi
- Department of Orthopaedic Trauma, Tianjin Hospital, Tianjin, China
| | - Xin Geng
- Department of Radiology, Tianjin Hospital, Tianjin, China
| | - Xiaokun Yu
- Department of Radiology, The Fifth Centre Hospital of Tianjin City, Tianjin, China
| | - Wenhuan Chen
- Third Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Jian Jia
- Department of Orthopaedic Trauma, Tianjin Hospital, Tianjin, China
| | - Wei Tian
- Department of Orthopaedic Trauma, Tianjin Hospital, Tianjin, China
| |
Collapse
|