Mandelka E, Gierse J, Zimmermann F, Gruetzner PA, Franke J, Vetter SY. Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter/pedicle width ratio. Brain Spine 2023; 3:101780. [PMID: 38020982 PMCID: PMC10668071 DOI: 10.1016/j.bas.2023.101780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 05/22/2023] [Accepted: 07/10/2023] [Indexed: 12/01/2023]
Abstract
Introduction There is ample evidence that higher accuracy can be achieved in thoracolumbar pedicle screw placement by using spinal navigation. Still, to date, the evidence regarding the influence of the use of navigation on the screw diameter to pedicle width ratio remains limited. Research question The aim of this study was to investigate the implications of navigation in thoracolumbar pedicle screw placement not only on screw accuracy, but on the screw diameter to pedicle width ratio as well. Material and methods In this single-center single-surgeon study, 45 Patients undergoing navigated thoracolumbar pedicle screw placement were prospectively included. The results were compared with a matched comparison group of patients in which screw placement was performed under fluoroscopic guidance. The screw accuracy and the screw diameter to pedicle width ratio of every screw were compared between the groups. Results Screw accuracy was significantly higher in the navigation group compared to the fluoroscopic guidance group, alongside with a significant increase of the screw diameter to pedicle width ratio by approximately 10%. In addition, both the intraoperative radiation dose and the operating time tended to be lower in the study group. Conclusion This study was able to show that navigated thoracolumbar pedicle screw placement not only increases the accuracy of screw placement but also facilitates the selection of the adequate screw sizes, which according to the literature has positive effects on fixation strength. Meanwhile, the use of navigation did not negatively affect the time needed for surgery or the patient's intraoperative exposure to radiation.
Collapse
Affiliation(s)
- Eric Mandelka
- Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
| | - Jula Gierse
- Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
| | - Felix Zimmermann
- Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
| | - Paul A. Gruetzner
- Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
| | - Jochen Franke
- Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
| | - Sven Y. Vetter
- Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
| |
Collapse
|
2
|
Croci DM, Nguyen S, Streitmatter SW, Sherrod BA, Hardy J, Cole KL, Gamblin AS, Bisson EF, Mazur MD, Dailey AT. O-Arm Accuracy and Radiation Exposure in Adult Deformity Surgery. World Neurosurg 2023; 171:e440-e446. [PMID: 36528322 DOI: 10.1016/j.wneu.2022.12.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 12/06/2022] [Accepted: 12/07/2022] [Indexed: 12/23/2022]
Abstract
OBJECTIVE In long thoracolumbar deformity surgery, accurate screw positioning is critical for spinal stability. We assessed pedicle and pelvic screw accuracy and radiation exposure in patients undergoing long thoracolumbar deformity fusion surgery (≥4 levels) involving 3-dimensional fluoroscopy (O-Arm/Stealth) navigation. METHODS In this retrospective single-center cohort study, all patients aged >18 years who underwent fusion in 2016-2018 were reviewed. O-Arm images were assessed for screw accuracy. Effective radiation doses were calculated. The primary outcome was pedicle screw accuracy (Heary grade). Secondary outcomes were pelvic fixation screw accuracy, radiation exposure, and screw-related perioperative and postoperative complications or revision surgery within 3 years. RESULTS Of 1477 pedicle screws placed in 91 patients (mean 16.41 ± 5.6 screws/patient), 1208 pedicle screws (81.8%) could be evaluated by 3-dimensional imaging after placement. Heary Grade I placement was achieved in 1150 screws (95.2%), Grade II in 47 (3.9%), Grade III in 10 (0.82%), Grade IV in 1 (0.08%), and Grade V in 0; Grade III-V were replaced intraoperatively. One of 60 (1.6%) sacroiliac screws placed showed medial cortical breach and was replaced. The average O-Arm-related effective dose was 29.54 ± 14.29 mSv and effective dose/spin was 8.25 ± 2.65 mSv. No postoperative neurological worsening, vascular injuries, or revision surgeries for screw misplacement were recorded. CONCLUSIONS With effective radiation doses similar to those in interventional neuroendovascular procedures, the use of O-Arm in multilevel complex deformity surgery resulted in high screw accuracy, no need for surgical revision because of screw malposition, less additional imaging, and no radiation exposure for the surgical team.
Collapse
Affiliation(s)
- Davide Marco Croci
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA
| | - Sarah Nguyen
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA
| | - Seth W Streitmatter
- Medical Imaging Physics and Radiation Safety, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | - Brandon A Sherrod
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA
| | - Jeremy Hardy
- School of Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Kyril L Cole
- School of Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Austin S Gamblin
- School of Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Erica F Bisson
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA
| | - Marcus D Mazur
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA
| | - Andrew T Dailey
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA.
| |
Collapse
|
3
|
Matur AV, Palmisciano P, Duah HO, Chilakapati SS, Cheng JS, Adogwa O. Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis. Spine J 2023; 23:197-208. [PMID: 36273761 DOI: 10.1016/j.spinee.2022.10.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 01/15/2023]
Abstract
BACKGROUND CONTEXT Navigated and robotic pedicle screw placement systems have been developed to improve the accuracy of screw placement. However, the literature comparing the safety and accuracy of robotic and navigated screw placement with fluoroscopic freehand screw placement in thoracolumbar spine surgery has been limited. PURPOSE To perform a systematic review and meta-analysis of randomized control trials that compared the accuracy and safety profiles of robotic and navigated pedicle screws with fluoroscopic freehand pedicle screws. STUDY DESIGN/SETTING Systematic review and meta-analysis PATIENT SAMPLE: Only randomized controlled trials comparing robotic-assisted or navigated pedicle screws placement with freehand pedicle screw placement in the thoracolumbar spine were included. OUTCOME MEASURES Odds ratio (OR) estimates for screw accuracy according to the Gertzbein-Robbins scale and relative risk (RR) for various surgical complications. METHODS We systematically searched PubMed and EMBASE for English-language studies from inception through April 7, 2022, including references of eligible articles. The search was conducted according to PRISMA guidelines. Two reviewers conducted a full abstraction of all data, and one reviewer verified accuracy. Information was extracted on study design, quality, bias, participants, and risk estimates. Data and estimates were pooled using the Mantel-Haenszel method for random-effects meta-analysis. RESULTS A total of 14 papers encompassing 12 randomized controlled trials were identified (n=892 patients, 4,046 screws). The pooled analysis demonstrated that robotic and navigated pedicle screw placement techniques were associated with higher odds of screw accuracy (OR 2.66, 95% CI 1.24-5.72, p=.01). Robotic and navigated screw placement was associated with a lower risk of facet joint violations (RR 0.09, 95% CI 0.02-0.38, p<.01) and major complications (RR 0.31, 95% CI 0.11-0.84, p=.02). There were no observed differences between groups in nerve root injury (RR 0.50, 95% CI 0.11-2.30, p=.37), or return to operating room for screw revision (RR 0.28, 95% CI 0.07-1.13, p=.07). CONCLUSIONS These estimates suggest that robotic and navigated screw placement techniques are associated with higher odds of screw accuracy and superior safety profile compared with fluoroscopic freehand techniques. Additional randomized controlled trials will be needed to further validate these findings.
Collapse
Affiliation(s)
- Abhijith V Matur
- Department of Neurosurgery, University of Cincinnati College of Medicine, 231 Albert Sabin Way, Cincinnati, OH 45229, USA
| | - Paolo Palmisciano
- Department of Neurosurgery, University of Cincinnati College of Medicine, 231 Albert Sabin Way, Cincinnati, OH 45229, USA
| | - Henry O Duah
- Department of Nursing Research, University of Cincinnati College of Nursing, Cincinnati, OH, USA
| | | | - Joseph S Cheng
- Department of Neurosurgery, University of Cincinnati College of Medicine, 231 Albert Sabin Way, Cincinnati, OH 45229, USA
| | - Owoicho Adogwa
- Department of Neurosurgery, University of Cincinnati College of Medicine, 231 Albert Sabin Way, Cincinnati, OH 45229, USA.
| |
Collapse
|
4
|
Di Perna G, Marengo N, Matsukawa K, Mahieu G, Baldassarre BM, Petrone S, De Marco R, Zeppa P, Ajello M, Fiumefreddo A, Zenga F, Garbossa D, Cofano F. Three-Dimensional Patient-Matched Template Guides Are Able to Increase Mean Diameter and Length and to Improve Accuracy of Cortical Bone Trajectory Screws: A 5-Year International Experience. World Neurosurg 2023; 170:e542-e549. [PMID: 36402304 DOI: 10.1016/j.wneu.2022.11.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 11/13/2022] [Accepted: 11/14/2022] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To analyze whether significant differences exist between free-hand three-dimensional (3D) planning-guided cortical bone trajectory (CBT) screw placement and 3D-printed template-guided CBT screw positioning in terms of accuracy, size of screws, and potential complications. METHODS In this retrospective study, data of adult patients in whom CBT screws were placed for lumbar degenerative pathologies were extracted from a prospectively collected database and analyzed. Patients in whom screws were placed using free-hand 3D planning-guided technique were compared with patients in whom screws were positioned using customized 3D-printed templates. Size of the screws, accuracy, clinical outcomes, and complications were analyzed. RESULTS The study evaluated 251 patients (1004 screws). The free-hand 3D planning-guided group included 158 patients (632 screws), and the 3D-printed template-guided group included 93 patients (372 screws). The 3D-printed template-guided group involved screws of larger size from L3 to S1. Differences between the 2 groups in terms of accuracy parameters reached statistical significance (P ≤ 0.05). CONCLUSIONS With the use of 3D patient-matched template guides, mean diameter and length of CBT screws could be safely increased due to improved accuracy of screw placement. Based on previous evidence regarding CBT biomechanical properties, these advantages could allow increased fixation strength over traditional convergent pedicle screw trajectories. Further biomechanics studies are needed.
Collapse
Affiliation(s)
- Giuseppe Di Perna
- Department of Neuroscience "Rita Levi Montalcini", University of Turin, Turin, Italy; Spine Surgery Unit, "Casa di Cura Clinica Città di Bra", Bra, Italy
| | - Nicola Marengo
- Neurosurgery Unit, "Città della Salute e della Scienza" University Hospital, Turin, Italy
| | - Keitaro Matsukawa
- Department of Orthopaedic Surgery, National Hospital Organization, Murayama Medical Center, Musashimurayama, Tokyo, Japan
| | - Geert Mahieu
- Orthopaedic Surgery Department, ORTHOCA - AZ Monica Hospital, Antwerp, Belgium
| | | | | | - Raffaele De Marco
- Department of Neuroscience "Rita Levi Montalcini", University of Turin, Turin, Italy.
| | - Pietro Zeppa
- Department of Neuroscience "Rita Levi Montalcini", University of Turin, Turin, Italy
| | - Marco Ajello
- Neurosurgery Unit, "Città della Salute e della Scienza" University Hospital, Turin, Italy
| | - Alessandro Fiumefreddo
- Neurosurgery Unit, "Città della Salute e della Scienza" University Hospital, Turin, Italy
| | - Francesco Zenga
- Neurosurgery Unit, "Città della Salute e della Scienza" University Hospital, Turin, Italy
| | - Diego Garbossa
- Department of Neuroscience "Rita Levi Montalcini", University of Turin, Turin, Italy; Neurosurgery Unit, "Città della Salute e della Scienza" University Hospital, Turin, Italy
| | - Fabio Cofano
- Department of Neuroscience "Rita Levi Montalcini", University of Turin, Turin, Italy; Spine Surgery Unit, Humanitas Gradenigo Hospital, Turin, Italy
| |
Collapse
|
5
|
Scarone P, Chatterjea A, Jenniskens I, Klüter T, Weuster M, Lippross S, Presilla S, Distefano D, Chianca V, Sedaghat S, Nelson M, Lampe F, Seekamp A. Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system. Eur Spine J 2022; 31:3098-3108. [PMID: 36149493 DOI: 10.1007/s00586-022-07387-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 09/05/2022] [Accepted: 09/11/2022] [Indexed: 06/16/2023]
Abstract
STUDY DESIGN Prospective multi-center study. OBJECTIVE The study aimed to evaluate the accuracy of pedicle screw placement using a skin marker-based optical surgical navigation system for minimal invasive thoraco-lumbar-sacral pedicle screw placement. METHODS The study was performed in a hybrid Operating Room with a video camera-based navigation system integrated in the imaging hardware. The patient was tracked with non-invasive skin markers while the instrument tracking was via an on-shaft optical marker pattern. The screw placement accuracy assessment was performed by three independent reviewers, using the Gertzbein grading. The screw placement time as well as the staff and patient radiation doses was also measured. RESULTS In total, 211 screws in 39 patients were analyzed for screw placement accuracy. Of these 32.7% were in the thoracic region, 59.7% were in the lumbar region, and 7.6% were in the sacral region. An overall accuracy of 98.1% was achieved. No screws were deemed severely misplaced (Gertzbein grading 3). The average time for screw placement was 6 min and 25 secs (± 3 min 33 secs). The average operator radiation dose per subject was 40.3 µSv. The mean patient effective dose (ED) was 11.94 mSv. CONCLUSION Skin marker-based ON can be used to achieve very accurate thoracolumbarsacral pedicle screw placements.
Collapse
Affiliation(s)
- Pietro Scarone
- Department of Neurosurgery, Neurocenter of Southern Switzerland, Ospedale Regionale Di Lugano Civico E Italiano, Lugano, Switzerland
| | - Anindita Chatterjea
- Image Guided Therapy Systems, Philips Healthcare, Veenpluis 6, 5684 PC, Best, The Netherlands.
| | - Inge Jenniskens
- Image Guided Therapy Systems, Philips Healthcare, Veenpluis 6, 5684 PC, Best, The Netherlands
| | - Tim Klüter
- Klinik Für Orthopädie Und Unfallchirurgie, UKSH, Campus Kiel, Kiel, Germany
| | - Matthias Weuster
- Klinik Für Orthopädie Und Unfallchirurgie, UKSH, Campus Kiel, Kiel, Germany
| | - Sebastian Lippross
- Klinik Für Orthopädie Und Unfallchirurgie, UKSH, Campus Kiel, Kiel, Germany
| | - Stefano Presilla
- Department of Neurosurgery, Neurocenter of Southern Switzerland, Ospedale Regionale Di Lugano Civico E Italiano, Lugano, Switzerland
| | - Daniela Distefano
- Department of Neuroradiology, Neurocenter of Southern Switzerland, Ospedale Regionale Di Lugano Civico E Italiano, Lugano, Switzerland
| | - Vito Chianca
- Clinica di Radiologia EOC IIMSI, Lugano, Switzerland
- Ospedale Evangelico Betania, Naples, Italy
| | - Sam Sedaghat
- Department of Neurosurgery, Neurocenter of Southern Switzerland, Ospedale Regionale Di Lugano Civico E Italiano, Lugano, Switzerland
| | - Melissa Nelson
- Image Guided Therapy Systems, Philips Healthcare, Veenpluis 6, 5684 PC, Best, The Netherlands
| | - Finn Lampe
- Klinik Für Orthopädie Und Unfallchirurgie, UKSH, Campus Kiel, Kiel, Germany
| | - Andreas Seekamp
- Klinik Für Orthopädie Und Unfallchirurgie, UKSH, Campus Kiel, Kiel, Germany
| |
Collapse
|
6
|
Hagan MJ, Syed S, Leary OP, Persad-Paisley EM, Lin Y, Zheng B, Shao B, Abdulrazeq H, Yu JYH, Telfeian AE, Gokaslan ZL, Fridley JS, Oyelese AA. Pedicle Screw Placement Using Intraoperative Computed Tomography and Computer-Aided Spinal Navigation Improves Screw Accuracy and Avoids Postoperative Revisions: Single-Center Analysis of 1400 Pedicle Screws. World Neurosurg 2022; 160:e169-e179. [PMID: 34990843 DOI: 10.1016/j.wneu.2021.12.112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/28/2021] [Accepted: 12/29/2021] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Intraoperative computed tomography and navigation (iCT-Nav) is increasingly used to aid spinal instrumentation. We aimed to document the accuracy and revision rate of pedicle screw placement across many screws placed using iCT-Nav. We also assess patient-level factors predictive of high-grade pedicle breach. METHODS Medical records of patients who underwent iCT-Nav pedicle screw placement between 2015 and 2017 at a single center were retrospectively reviewed. Screw placement accuracy was individually assessed for each screw using the 2-mm incremental grading system for pedicle breach. Predictors of high-grade (>2 mm) breach were identified using multiple logistic regression. RESULTS In total, 1400 pedicle screws were placed in 208 patients undergoing cervicothoracic (29; 13.9%), thoracic (30; 14.4), thoracolumbar (19; 9.1%) and lumbar (130; 62.5%) surgeries. iCT-Nav afforded high-accuracy screw placement, with 1356 of 1400 screws (96.9%) being placed accurately. In total, 37 pedicle screws (2.64%) were revised intraoperatively during the index surgery across 31 patients, with no subsequent returns to the operating room because of screw malpositioning. After correcting for potential confounders, males were less likely to have a high-grade breach (odds ratio [OR] 0.21; 95% confidence interval [CI] 0.10-0.59, P = 0.003) whereas lateral (OR 6.21; 95% CI 2.47-15.52, P < 0.001) or anterior (OR 5.79; 95% CI2.11-15.88, P = 0.001) breach location were predictive of a high-grade breach. CONCLUSIONS iCT-Nav with postinstrumentation intraoperative imaging is associated with a reduced need for costly postoperative return to the operating room for screw revision. In comparison with studies of navigation without iCT where 1.5%-1.7% of patients returned for a second surgery, we report 0 revision surgeries due to screw malpositioning.
Collapse
Affiliation(s)
- Matthew J Hagan
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA
| | - Sohail Syed
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | - Owen P Leary
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | | | - Yang Lin
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA
| | - Bryan Zheng
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA
| | - Belinda Shao
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | - Hael Abdulrazeq
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | - James Y H Yu
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA
| | - Albert E Telfeian
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | - Ziya L Gokaslan
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | - Jared S Fridley
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA
| | - Adetokunbo A Oyelese
- The Warren Alpert School of Medicine, Brown University, Providence, Rhode Island, USA; Department of Neurosurgery, Rhode Island Hospital, Providence, Rhode Island, USA.
| |
Collapse
|
7
|
Sancipriano V, Penner F, Cofano F, Ajello M, Marengo N, Petrone S, Zenga F, Crobeddu M, Bianco A, Cossandi C, Garbossa D. Intraoperative Computed Tomography for C1-C2 Stabilization by Goel-Harms: Analysis of Clinical Efficacy and a Novel Classification of Screw Placement Accuracy. World Neurosurg 2021:S1878-8750(21)01560-6. [PMID: 34648982 DOI: 10.1016/j.wneu.2021.10.063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND The introduction of intraoperative computed tomography (iCT) could improve the surgical results of C1-C2 stabilization by Goel-Harms, especially in patients with complex deformities. This study aims to investigate the impact of iCT on the accuracy of C1-C2 screw positioning and to develop a score based on multiparametric analysis of imaging data (Cervical Screw Placement Accuracy score [CSPAs]). METHODS Twenty-one patients were retrospectively evaluated. The data obtained with the use of an iCT were compared with the incidence of cases of malpositioning in the literature. Multiparametric imaging criteria were developed: the 82 screw positions were evaluated using the CSPA criteria and 2 additional variables. The CSPAs was obtained from the aggregation of the CSPAs criteria: optimal (CSPAs ≥8), suboptimal (CSPAs = 6-7), malpositioned (CSPAs ≤5). RESULTS The average incidence of malpositioning in C1-C2 arthrodesis decreased from 13% without iCT to 1.2% with the aid of iCT, considering a monoparametric value. The CSPAs analysis shows a greater discretion and higher number of well-defined categories of the accuracy of C1-C2 screw position: optimal, 80.3%; suboptimal, 17.1%; and malposition, 2.6%. A correlation was observed between the accuracy of the positioning of both right and left screws in C2. Furthermore, the anatomic site of C2 screws was found to be a predictor of cortical invasion. CONCLUSIONS The results suggest that the introduction of the iCT is associated with a consistent improvement of the accuracy in the positioning of the screws. A multiparametric score (CSPAs) could improve the assessment of screw placement.
Collapse
|
8
|
Lee NJ, Zuckerman SL, Buchanan IA, Boddapati V, Mathew J, Leung E, Park PJ, Pham MH, Buchholz AL, Khan A, Pollina J, Mullin JP, Jazini E, Haines C, Schuler TC, Good CR, Lombardi JM, Lehman RA. Is there a difference between navigated and non-navigated robot cohorts in robot-assisted spine surgery? A multicenter, propensity-matched analysis of 2,800 screws and 372 patients. Spine J 2021; 21:1504-1512. [PMID: 34022461 DOI: 10.1016/j.spinee.2021.05.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/23/2021] [Accepted: 05/12/2021] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Robot-assisted spine surgery continues to rapidly develop as evidenced by the growing literature in recent years. In addition to demonstrating excellent pedicle screw accuracy, early studies have explored the impact of robot-assisted spine surgery on reducing radiation time, length of hospital stay, operative time, and perioperative complications in comparison to conventional freehand technique. Recently, the Mazor X Stealth Edition was introduced in 2018. This robotic system integrates Medtronic's Stealth navigation technology into the Mazor X platform, which was introduced in 2016. It is unclear what the impact of these advancements have made on clinical outcomes. PURPOSE To compare the outcomes and complications between the most recent iterations of the Mazor Robot systems: Mazor X and Mazor X Stealth Edition. STUDY DESIGN Multicenter cohort PATIENT SAMPLE: Among four different institutions, we included adult (≥18 years old) patients who underwent robot-assisted spine surgery with either the Mazor X (non-navigated robot) or Stealth (navigated robot) platforms. OUTCOME MEASURES Primary outcomes included robot time per screw, fluoroscopic radiation time, screw accuracy, robot abandonment, and clinical outcomes with a minimum 90 day follow up. METHODS A one-to-one propensity-score matching algorithm based on perioperative factors (e.g. demographics, comorbidities, primary diagnosis, open vs. percutaneous instrumentation, prior spine surgery, instrumented levels, pelvic fixation, interbody fusion, number of planned robot screws) was employed to control for the potential selection bias between the two robotic systems. Chi-square/fisher exact test and t-test/ANOVA were used for categorical and continuous variables, respectively. RESULTS From a total of 646 patients, a total of 372 adult patients were included in this study (X: 186, Stealth: 186) after propensity score matching. The mean number of instrumented levels was 4.3. The mean number of planned robot screws was 7.8. Similar total operative time and robot time per screw occurred between cohorts (p>0.05). However, Stealth achieved significantly shorter fluoroscopic radiation time per screw (Stealth: 7.2 seconds vs. X: 10.4 seconds, p<.001) than X. The screw accuracy for both robots was excellent (Stealth: 99.6% vs. X: 99.1%, p=0.120). In addition, Stealth achieved a significantly lower robot abandonment rate (Stealth: 0% vs. X: 2.2%, p=0.044). Furthermore, a lower blood transfusion rate was observed for Stealth than X (Stealth: 4.3% vs. X: 10.8%, p=0.018). Non-robot related complications such as dura tear, motor/sensory deficits, return to the operating room during same admission, and length of stay was similar between robots (p>0.05). The 90-day complication rates were low and similar between robot cohorts (Stealth: 5.4% vs. X: 3.8%, p=0.456). CONCLUSION In this multicenter study, both robot systems achieved excellent screw accuracy and low robot time per screw. However, using Stealth led to significantly less fluoroscopic radiation time, lower robot abandonment rates, and reduced blood transfusion rates than Mazor X. Other factors including length of stay, and 90-day complications were similar.
Collapse
Affiliation(s)
- Nathan J Lee
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA.
| | - Scott L Zuckerman
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Ian A Buchanan
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Venkat Boddapati
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Justin Mathew
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Eric Leung
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Paul J Park
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Martin H Pham
- Department of Neurosurgery, University of San Diego Health, Sand Diego, CA, USA
| | - Avery L Buchholz
- Department of Neurosurgery, University of Virginia Health System, Charlottesville, VA, USA
| | - Asham Khan
- Department of Neurosurgery, State University of New York, Buffalo, NY, USA
| | - John Pollina
- Department of Neurosurgery, State University of New York, Buffalo, NY, USA
| | - Jeffrey P Mullin
- Department of Neurosurgery, State University of New York, Buffalo, NY, USA
| | - Ehsan Jazini
- Department of Orthopaedics, Virginia Spine Institute, Reston, VA, USA
| | - Colin Haines
- Department of Orthopaedics, Virginia Spine Institute, Reston, VA, USA
| | - Thomas C Schuler
- Department of Orthopaedics, Virginia Spine Institute, Reston, VA, USA
| | | | - Joseph M Lombardi
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| | - Ronald A Lehman
- Department of Orthopaedics, Columbia University Medical Center, The Och Spine Hospital at New York-Presbyterian, New York, NY, USA
| |
Collapse
|
9
|
Banat M, Wach J, Salemdawod A, Bahna M, Scorzin J, Vatter H. The Role of Intraoperative Image Guidance Systems (Three-Dimensional C-arm versus O-arm) in Spinal Surgery: Results of a Single-Center Study. World Neurosurg 2020; 146:e817-e821. [PMID: 33181376 DOI: 10.1016/j.wneu.2020.11.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 11/03/2020] [Accepted: 11/04/2020] [Indexed: 12/09/2022]
Abstract
OBJECTIVE Spinal dorsal instrumentation is an established treatment option for a range of spinal disorders. In combination with navigation, intraoperative fluoroscopy reduces the risk of incorrectly placing screws. This study aimed to evaluate the efficacy and validity of fluoroscopy (intraoperative navigation with three-dimensional rotation of C-arm vs. O-arm). METHODS In this retrospective single-center study, 240 patients were included between July 2017 and April 2020. Intraoperative images were acquired using a Siemens-Arcadis Orbic 3D C-arm with a navigation system (Brainlab, AG, Munich, Germany) or using O-arm (Medtronic, Minneapolis, Minnesota, USA) with a navigation system (S7 StealthStation). Finally, we compared mismatches between intraoperative and postoperative computed tomography imaging results using Rampersaud-grade (A-D). RESULTS A total of 1614 screws were included: 94 patients in the C-arm group (cAG) and 146 in the O-arm group (oAG). In cAG, 3% (n = 20) of the screws had to be replaced directly due to inadequate positioning with median or lateral breaches, and 3.5 % of screws in oAG (n = 35). An A-score was achieved for 85.7% in the cAG and 87.4% in the oAG. A B-score was found in 11.5% in the cAG and 11.9% in the oAG. In the cAG, a C-score was achieved for 2.5% and in oAG for 0.7%. For 0.3% of the screws, a D-score was found in cAG and for none in oAG. CONCLUSIONS Our study shows that placement of screws using intraoperative imaging in combination with a navigation tool is accurate. Furthermore, navigation coupled with the O-arm had significant advantages in accuracy over navigation with 3D C-arm fluoroscopy. However, both systems offer a high level of accuracy.
Collapse
Affiliation(s)
- Mohammed Banat
- Klinik und Poliklinik für Neurochirurgie, Universitätsklinikum Bonn, Bonn, Germany.
| | - Johannes Wach
- Klinik und Poliklinik für Neurochirurgie, Universitätsklinikum Bonn, Bonn, Germany
| | - Abduallah Salemdawod
- Klinik und Poliklinik für Neurochirurgie, Universitätsklinikum Bonn, Bonn, Germany
| | - Majd Bahna
- Klinik und Poliklinik für Neurochirurgie, Universitätsklinikum Bonn, Bonn, Germany
| | - Jasmin Scorzin
- Klinik und Poliklinik für Neurochirurgie, Universitätsklinikum Bonn, Bonn, Germany
| | - Hartmut Vatter
- Klinik und Poliklinik für Neurochirurgie, Universitätsklinikum Bonn, Bonn, Germany
| |
Collapse
|
10
|
Benech CA, Perez R, Benech F, Greeley SL, Crawford N, Ledonio C. Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 cases. J Robot Surg 2020; 14:431-7. [PMID: 31396848 DOI: 10.1007/s11701-019-01007-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 07/24/2019] [Indexed: 12/11/2022]
Abstract
Computer-aided navigation and robotic guidance systems have become widespread in their utilization for spine surgery. A recent innovation combines these two advances, which theoretically provides accuracy in spinal screw placement. This study describes the cortical and pedicle screw accuracy for the first 54 cases where navigated robotic assistance was used in a surgical setting. This is a retrospective chart review of the initial 54 patients undergoing spine surgery with pedicle and cortical screws using robotic guidance with navigation. A computed tomography (CT)-based Gertzbein and Robbins System (GRS) was used to classify pedicle screw accuracy. Screw tip, tail, and angulation offsets were measured using image overlay analysis. Screw malposition, reposition, and return to operating room rates were collected. 1 of the first 54 cases was a revision surgery and was excluded from the study. Ten screws were placed without the robot due to surgeon discretion and were excluded for the data analysis of 292 screws. Only 0.68% (2/292) of the robot-assisted screws was repositioned based on surgeon discretion. Based on the GRS CT-based grading, 98.3% (287/292) were graded A or B, 1.0% (3/292) screws were graded C, and only 0.7% (2/292) screws was graded D. The average offset from preoperative plan to actual final placement was 1.9 mm from the tip, 2.3 mm from the tail, and 2.8° of angulation. In the first 53 cases, 292 screws placed with navigated robotic assistance resulted in a high level of accuracy (98.3%), adequate screw offsets from planned trajectory, and zero complications.
Collapse
|