1
|
Behrendt T, Quisilima JI, Bielitzki R, Behrens M, Glazachev OS, Brigadski T, Leßmann V, Schega L. Brain-Derived neurotrophic factor and inflammatory biomarkers are unaffected by acute and chronic intermittent hypoxic-hyperoxic exposure in geriatric patients: a randomized controlled trial. Ann Med 2024; 56:2304650. [PMID: 38253008 PMCID: PMC10810628 DOI: 10.1080/07853890.2024.2304650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 11/24/2023] [Indexed: 01/24/2024] Open
Abstract
BACKGROUND Animal and human studies have shown that exposure to hypoxia can increase brain-derived neurotrophic factor (BDNF) protein transcription and reduce systematic inflammatory cytokine response. Therefore, the aim of this study was to investigate the acute and chronic effects of intermittent hypoxic-hyperoxic exposure (IHHE) prior to aerobic exercise on BDNF, interleukin-6 (IL-6), and C-reactive protein (CRP) blood levels in geriatric patients. PATIENTS AND METHODS Twenty-five geriatric patients (83.1 ± 5.0 yrs, 71.1 ± 10.0 kg, 1.8 ± 0.9 m) participated in a placebo-controlled, single-blinded trial and were randomly assigned to either an intervention (IG) or control group (CG) performing an aerobic cycling training (17 sessions, 20 min·session-1, 3 sessions·week-1). Prior to aerobic cycling exercise, the IG was additionally exposed to IHHE for 30 min, whereas the CG received continuous normoxic air. Blood samples were taken immediately before (pre-exercise) and 10 min (post-exercise) after the first session as well as 48 h (post-training) after the last session to determine serum (BDNFS) and plasma BDNF (BDNFP), IL-6, and CRP levels. Intervention effects were analyzed using a 2 x 2 analysis of covariance with repeated measures. Results were interpreted based on effect sizes with a medium effect considered as meaningful (ηp2 ≥ 0.06, d ≥ 0.5). RESULTS CRP was moderately higher (d = 0.51) in the CG compared to the IG at baseline. IHHE had no acute effect on BDNFS (ηp2 = 0.01), BDNFP (ηp2 < 0.01), BDNF serum/plasma-ratio (ηp2 < 0.01), IL-6 (ηp2 < 0.01), or CRP (ηp2 = 0.04). After the 6-week intervention, an interaction was found for BDNF serum/plasma-ratio (ηp2 = 0.06) but not for BDNFS (ηp2 = 0.04), BDNFP (ηp2 < 0.01), IL-6 (ηp2 < 0.01), or CRP (ηp2 < 0.01). BDNF serum/plasma-ratio increased from pre-exercise to post-training (d = 0.67) in the CG compared to the IG (d = 0.51). A main effect of time was found for BDNFP (ηp2 = 0.09) but not for BDNFS (ηp2 = 0.02). Within-group post-hoc analyses revealed a training-related reduction in BDNFP in the IG and CG by 46.1% (d = 0.73) and 24.7% (d = 0.57), respectively. CONCLUSION The addition of 30 min IHHE prior to 20 min aerobic cycling seems not to be effective to increase BDNFS and BDNFP or to reduce IL-6 and CRP levels in geriatric patients after a 6-week intervention.The study was retrospectively registered at drks.de (DRKS-ID: DRKS00025130).
Collapse
Affiliation(s)
- Tom Behrendt
- Department of Sport Science, Chair for Health and Physical Activity, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Jessica Ibanez Quisilima
- Department of Sport Science, Chair for Health and Physical Activity, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Robert Bielitzki
- Department of Sport Science, Chair for Health and Physical Activity, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Martin Behrens
- University of Applied Sciences for Sport and Management Potsdam, Potsdam, Germany
| | - Oleg S. Glazachev
- Department of Human Physiology, Institute of Clinical Medicine, I.M. Sechenov First Moscow State Medical University, Moscow, Russia
| | - Tanja Brigadski
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany
| | - Volkmar Leßmann
- Institute of Physiology, Otto-von-Guericke University Magdeburg, Medical Faculty, Magdeburg, Germany
- Center for Behavioral Brain Sciences, Magdeburg, Germany
| | - Lutz Schega
- Department of Sport Science, Chair for Health and Physical Activity, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
2
|
Ramírez-delaCruz M, Bravo-Sánchez A, Sánchez-Infante J, Abián P, Abián-Vicén J. Effects of Acute Hypoxic Exposure in Simulated Altitude in Healthy Adults on Cognitive Performance: A Systematic Review and Meta-Analysis. BIOLOGY 2024; 13:835. [PMID: 39452143 PMCID: PMC11504018 DOI: 10.3390/biology13100835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2024] [Revised: 09/30/2024] [Accepted: 10/14/2024] [Indexed: 10/26/2024]
Abstract
The neurocognitive response following hypoxia has received special interest. However, it is necessary to understand the impact of acute hypoxic exposure induced by simulated altitude on cognitive performance. This study aimed to determine the effects of acute hypoxic exposure in simulated altitude in healthy adults on reaction time, response accuracy, memory, and attention. Five electronic databases were searched. The inclusion criteria were: (1) Experimental studies involving a hypoxia intervention induced by a hypoxic air generator to determine the effects on cognitive performance; and (2) Conducted in adults (males and/or females; aged 18-50 years) without pathologies or health/mental problems. Four meta-analyses were performed: (1) reaction time, (2) response accuracy, (3) memory, and (4) attention. Finally, 37 studies were included in the meta-analysis. Hypoxia exposure induced detrimental effects on reaction time (standard mean difference (SMD) -0.23; 95% confidence interval (CI) -0.38--0.07; p = 0.004), response accuracy (SMD -0.20; 95% CI -0.38--0.03; p = 0.02), and memory (SMD -0.93; 95% CI: -1.68--0.17; p = 0.02). Nevertheless, attention was not affected during hypoxia exposure (SMD -0.06; 95% CI: -0.23-0.11; p = 0.47). Acute exposure to hypoxia in controlled lab conditions appears to be detrimental to cognitive performance, specifically in reaction time, response accuracy, and memory.
Collapse
Affiliation(s)
- María Ramírez-delaCruz
- Performance and Sport Rehabilitation Laboratory, Faculty of Sports Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain;
| | - Alfredo Bravo-Sánchez
- Faculty of Health Sciences, Universidad Francisco de Vitoria, Ctra. Pozuelo-Majadahonda km 1800, 28223 Pozuelo de Alarcón, Spain; (A.B.-S.); (J.S.-I.)
| | - Jorge Sánchez-Infante
- Faculty of Health Sciences, Universidad Francisco de Vitoria, Ctra. Pozuelo-Majadahonda km 1800, 28223 Pozuelo de Alarcón, Spain; (A.B.-S.); (J.S.-I.)
- Toledo Physiotherapy Research Group (GIFTO), Faculty of Physiotherapy and Nursing of Toledo, Universidad de Castilla-La Mancha, 45071 Toledo, Spain
| | - Pablo Abián
- Faculty of Humanities and Social Sciences, Comillas Pontifical University, 28049 Madrid, Spain;
| | - Javier Abián-Vicén
- Performance and Sport Rehabilitation Laboratory, Faculty of Sports Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain;
| |
Collapse
|
3
|
Oberholzer L, Aamaas NS, Hallén J. Changes in cycling economy and fractional utilization of V̇O 2peak during a 40-min maximal effort exercise test with acute hypobaric hypoxia corresponding to 2800 m of altitude. Scand J Med Sci Sports 2024; 34:e14511. [PMID: 37828810 DOI: 10.1111/sms.14511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 09/16/2023] [Accepted: 09/25/2023] [Indexed: 10/14/2023]
Abstract
INTRODUCTION Peak oxygen uptake (V̇O2peak ) declines by ~7% per 1000 m of increasing altitude, whereas exercise performance seems reduced to a lesser extent. For example, 800-10 000 m track and field performances are decreased by 0.4%-2.4% above 1000 m as compared to below and some studies show similar drops in cycling performance. A greater decline in V̇O2peak than in endurance performance with altitude suggests a higher fractional utilization of V̇O2peak (%V̇O2peak ). Therefore, we hypothesized that the %V̇O2peak is higher with acute hypoxic exposure than near sea level. METHODS Sixteen lowlanders (8 women, age: 31 ± 7 years [mean ± SD], body mass: 68 ± 8 kg, V̇O2peak : 60 ± 8 mL min-1 kg-1 ) underwent cycling testing in a hypobaric hypoxic chamber on 6 test days, three conducted at 300 m and three at 2800 m of acute altitude. At both altitudes, V̇O2peak was determined, and during a 40-min all out maximal effort time trial (TT), mean power output (MPO) and mean V̇O2 (%V̇O2peak ) were assessed. RESULTS V̇O2peak decreased by 11.2 ± 3.0% (p < 0.001), while MPO during the TT declined by 10.7 ± 3.1% (p < 0.001) at 2800 m as compared to 300 m. During the TT, %V̇O2peak was higher at altitude, corresponding to 75.9 ± 4.5% at 300 m and 78.8 ± 4.2% at 2800 m (p = 0.011), and cycling economy (mL O2 kJ-1 ) was poorer (+3.4 ± 2.7%, p < 0.001). CONCLUSION The %V̇O2peak was higher during a cycling TT at 2800 m of altitude than near sea level, while cycling economy was poorer. This resulted in a similar reduction in performance and V̇O2peak . Future studies should address the physiological mechanisms underlying the elevated %V̇O2peak .
Collapse
Affiliation(s)
- Laura Oberholzer
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | | | - Jostein Hallén
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| |
Collapse
|
4
|
Bottenheft C, Groen EL, Mol D, Valk PJL, Houben MMJ, Kingma BRM, van Erp JBF. Effects of heat load and hypobaric hypoxia on cognitive performance: a combined stressor approach. ERGONOMICS 2023; 66:2148-2164. [PMID: 36916391 DOI: 10.1080/00140139.2023.2190062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Accepted: 03/05/2023] [Indexed: 06/18/2023]
Abstract
This study investigates how cognitive performance is affected by the combination of two stressors that are operationally relevant for helicopter pilots: heat load and hypobaric hypoxia. Fifteen participants were exposed to (1) no stressors, (2) heat load, (3) hypobaric hypoxia, and (4) combined heat load and hypobaric hypoxia. Hypobaric hypoxia (13,000 ft) was achieved in a hypobaric chamber. Heat load was induced by increasing ambient temperature to ∼28 °C. Cognitive performance was measured using two multitasks, and a vigilance task. Subjective and physiological data (oxygen saturation, heart rate, core- and skin temperature) were also collected. Mainly heat load caused cognitive performance decline. This can be explained by high subjective heat load and increased skin temperature, which takes away cognitive resources from the tasks. Only the arithmetic subtask was sensitive to hypobaric hypoxia, whereby hypobaric hypoxia caused a further performance decline in addition to the decline caused by heat load.Practitioner summary: Little is known about how multiple environmental stressors interact. This study investigates the combined effects of heat load and hypobaric hypoxia on cognitive performance. An additive effect of heat load and hypobaric hypoxia was found on a arithmetic task, which may be attributed to independent underlying mechanisms.
Collapse
Affiliation(s)
- Charelle Bottenheft
- Department of Human Performance, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
- Human Media Interaction, Computer Science, University of Twente, Enschede, Netherlands
| | - Eric L Groen
- Department of Human Performance, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
| | - Douwe Mol
- Department of Human Performance, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
| | - Pierre J L Valk
- Department of Human Performance, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
| | - Mark M J Houben
- Department of Human Performance, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
| | - Boris R M Kingma
- Department of Human Performance, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
| | - Jan B F van Erp
- Human Media Interaction, Computer Science, University of Twente, Enschede, Netherlands
- Department of Human Machine Teaming, Unit Defence, Safety and Security, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, Netherlands
| |
Collapse
|
5
|
Ozan M, Buzdağli Y, Baygutalp NK, Yüce N, Baygutalp F, Bakan E. Serum BDNF and Selenium Levels in Elite Athletes Exposed to Blows. Medicina (B Aires) 2022; 58:medicina58050608. [PMID: 35630025 PMCID: PMC9145651 DOI: 10.3390/medicina58050608] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 04/18/2022] [Accepted: 04/23/2022] [Indexed: 11/21/2022] Open
Abstract
Background and Objectives: The study aimed to investigate the combined acute and long-term effects of exposure to blows and exercise on serum BDNF (brain-derived neurotrophic factor) and selenium levels. Materials and Methods: Serum BDNF and selenium levels were determined in 40 male elite athletes before and after vigorous exercise (training match) with a probability of exposure to blows and in 10 sedentary men subjected to exercise (Astrand running protocol). Results: Serum BDNF levels were found 11.50 ± 3.50 ng/mL before exercise and 14.02 ± 3.15 ng/mL after exercise in the athlete group (p = 0.02), and 12.18 ± 4.55 ng/ mL and 11.74 ± 2.48 ng/ mL before and after exercise in the sedentary group, respectively (p = 0.873). Serum BDNF (pre-exercise, baseline) levels were slightly lower in the athlete group than those in the sedentary group (11.50 ± 3.50 and 12.18 ± 4.55 ng/mL, respectively, p = 0.796). Pre-exercise serum selenium levels in athletes were significantly higher compared to those of sedentary participants (130.53 ± 36.79 and 95.51 ± 20.57 µg/L, respectively, p = 0.011). There was no difference in selenium levels after exercise (124.01 ± 29.96 µg/L) compared to pre-exercise (130.53 ± 36.79 µg/L) in the athlete group (p = 0.386). Similarly, there was no difference in selenium levels after exercise (113.28 ± 25.51 µg/L) compared to pre-exercise (95.51 ± 20.57 µg/L) in the sedentary group (p = 0.251). Conclusions: BDNF results show that even if athletes are exposed to blows, they may be protected from the long-term effects of blows thanks to the protective effect of their non-sedentary lifestyle. Regular exercise may have a protective effect on maintaining serum selenium levels in athletes even exposed to blows chronically.
Collapse
Affiliation(s)
- Murat Ozan
- Department of Physical Education and Sports, Kazım Karabekir Education Faculty, Ataturk University, Erzurum 25240, Turkey;
| | - Yusuf Buzdağli
- Department of Physical Education and Sports, Faculty of Sport Sciences, Erzurum Technical University, Erzurum 25240, Turkey;
| | - Nurcan Kılıç Baygutalp
- Department of Biochemistry, Faculty of Pharmacy, Ataturk University, Erzurum 25240, Turkey
- Correspondence: ; Tel.: +90-442-2315231
| | - Neslihan Yüce
- Department of Medical Biochemistry, Faculty of Medicine, Ataturk University, Erzurum 25240, Turkey;
| | - Fatih Baygutalp
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Ataturk University, Erzurum 25240, Turkey;
| | - Ebubekir Bakan
- Department of Biochemistry, Faculty of Medicine, Ağrı İbrahim Çeçen University, Ağrı 04100, Turkey;
| |
Collapse
|
6
|
Ohko H, Umemoto Y, Sakurai Y, Araki S, Kojima D, Kamijo Y, Murai K, Yasuoka Y, Tajima F. The effects of endurance exercise combined with high-temperature head-out water immersion on serum concentration of brain-derived neurotrophic factor in healthy young men. Int J Hyperthermia 2021; 38:1077-1085. [PMID: 34278925 DOI: 10.1080/02656736.2021.1922761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
OBJECTIVES To evaluate acute changes in serum brain-derived neurotrophic factor (BDNF) concentration following combined endurance exercise and heat stress through head-out water immersion (HOI). SETTING Observational study with crossover design. METHODS Ten healthy young male participants performed HOI at 40 °C (40 °C HOI) or continuous cycling at 60% of maximal oxygen uptake while immersed in 40 °C (40 °C HOI-ex) or 23 °C water (23 °C HOI-ex) for 15 min. Serum BDNF, cortisol and lactate concentrations, and core temperature (Tcore) were measured pre, immediately post, and 15 and 30 min post-immersion. RESULTS BDNF concentration increased immediately and 15 min after 40 °C HOI-ex, but not after 40 °C or 23 °C HOI-ex. No changes in Tcore concentration were observed during 23 °C HOI-ex (Pre; 37.3 °C ± 0.3 °C, Post; 37.8 °C ± 0.2 °C, Post 15; 37.4 °C ± 0.3 °C, Post 30; 37.2 °C ± 0.2 °C). Tcore increased significantly post, post 15, and post 30 min of 40 °C HOI (Pre; 37.1 °C ± 0.4 °C, Post; 38.8 °C ± 0.5 °C, Post 15; 37.9 °C ± 0.4 °C, Post 30; 37.9 °C ± 0.2 °C) and 40 °C HOI-ex (Pre; 37.2 °C ± 0.2 °C, Post; 40.2 °C ± 0.7 °C, Post 15; 38.9 °C ± 0.5 °C, Post 30; 38.3 °C ± 0.5 °C). Tcore was higher in 40 °C HOI-ex compared with 40 °C HOI and 23 °C HOI-ex immediately post and post 15 min. Plasma lactate and cortisol were significantly higher in 40 °C HOI-ex compared with 40 °C HOI and 23 °C HOI-ex after immersion (p = 0.001). CONCLUSION While 15 min HOI alone or thermoneutral exercise do not increase BDNF concentration, both combined may form a time-efficient strategy to acutely elevate BDNF.
Collapse
Affiliation(s)
- Hiroshi Ohko
- Department of Rehabilitation and Care, Seijoh University, Aichi, Japan
| | - Yasunori Umemoto
- Department of Rehabilitation Medicine, Wakayama Medical University, School of Medicine, Wakayama, Japan
| | - Yuta Sakurai
- Research Center of Sports Medicine and Balneology, Nachikatsuura Balneologic Town Hospital, Tenma-Nachikatuurachou, Japan
| | - Shouhei Araki
- Research Center of Sports Medicine and Balneology, Nachikatsuura Balneologic Town Hospital, Tenma-Nachikatuurachou, Japan
| | - Daisuke Kojima
- Department of Rehabilitation Medicine, Wakayama Medical University, School of Medicine, Wakayama, Japan
| | - Yoshiichiro Kamijo
- Department of Rehabilitation Medicine, Wakayama Medical University, School of Medicine, Wakayama, Japan
| | - Kota Murai
- Department of Rehabilitation Medicine, Wakayama Medical University, School of Medicine, Wakayama, Japan
| | - Yoshinori Yasuoka
- Department of Rehabilitation Medicine, Wakayama Medical University, School of Medicine, Wakayama, Japan
| | - Fumihiro Tajima
- Department of Rehabilitation Medicine, Wakayama Medical University, School of Medicine, Wakayama, Japan.,Research Center of Sports Medicine and Balneology, Nachikatsuura Balneologic Town Hospital, Tenma-Nachikatuurachou, Japan
| |
Collapse
|
7
|
McCleave EL, Slattery KM, Duffield R, Crowcroft S, Abbiss CR, Wallace LK, Coutts AJ. Concurrent Heat and Intermittent Hypoxic Training: No Additional Performance Benefit Over Temperate Training. Int J Sports Physiol Perform 2020; 15:1260-1271. [PMID: 32937599 DOI: 10.1123/ijspp.2019-0277] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 12/08/2019] [Accepted: 12/16/2019] [Indexed: 11/18/2022]
Abstract
PURPOSE To examine whether concurrent heat and intermittent hypoxic training can improve endurance performance and physiological responses relative to independent heat or temperate interval training. METHODS Well-trained male cyclists (N = 29) completed 3 weeks of moderate- to high-intensity interval training (4 × 60 min·wk-1) in 1 of 3 conditions: (1) heat (HOT: 32°C, 50% relative humidity, 20.8% fraction of inspired oxygen, (2) heat + hypoxia (H+H: 32°C, 50% relative humidity, 16.2% fraction of inspired oxygen), or (3) temperate environment (CONT: 22°C, 50% relative humidity, 20.8% fraction of inspired oxygen). Performance 20-km time trials (TTs) were conducted in both temperate (TTtemperate) and assigned condition (TTenvironment) before (base), immediately after (mid), and after a 3-week taper (end). Measures of hemoglobin mass, plasma volume, and blood volume were also assessed. RESULTS There was improved 20-km TT performance to a similar extent across all groups in both TTtemperate (mean ±90% confidence interval HOT, -2.8% ±1.8%; H+H, -2.0% ±1.5%; CONT, -2.0% ±1.8%) and TTenvironment (HOT, -3.3% ±1.7%; H+H, -3.1% ±1.6%; CONT, -3.2% ±1.1%). Plasma volume (HOT, 3.8% ±4.7%; H+H, 3.3% ±4.7%) and blood volume (HOT, 3.0% ±4.1%; H+H, 4.6% ±3.9%) were both increased at mid in HOT and H+H over CONT. Increased hemoglobin mass was observed in H+H only (3.0% ±1.8%). CONCLUSION Three weeks of interval training in heat, concurrent heat and hypoxia, or temperate environments improve 20-km TT performance to the same extent. Despite indications of physiological adaptations, the addition of independent heat or concurrent heat and hypoxia provided no greater performance benefits in a temperate environment than temperate training alone.
Collapse
|
8
|
Bradbury KE, Coffman KE, Mitchell KM, Luippold AJ, Fulco CS, Kenefick RW. Separate and combined influences of heat and hypobaric hypoxia on self-paced aerobic exercise performance. J Appl Physiol (1985) 2019; 127:513-519. [PMID: 31219777 DOI: 10.1152/japplphysiol.00023.2019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Heat and hypobaric hypoxia independently compromise exercise performance; however, their combined impact on exercise performance has yet to be quantified. This study examined the effects of heat, hypobaric hypoxia, and the combination of these environments on self-paced cycling time trial (TT) performance. Twelve subjects [2 female, 10 male; sea level (SL) peak oxygen consumption (V̇o2peak), 41.5 ± 4.4 mL·kg-1·min-1, mean ± SD] completed 30 min of steady-state cycling exercise (50% SL V̇o2peak), followed by a 15-min self-paced TT in four environmental conditions: SL thermoneutral [SLTN; 250 m, 20°C, 30-50% relative humidity (rh)], SL hot (SLH; 250 m, 35°C, 30% rh), hypobaric hypoxia thermoneutral (HTN; 3,000 m, 20°C, 30-50% rh), and hypobaric hypoxia hot (HH; 3,000 m, 35°C, 30% rh). Performance was assessed by the total work (kJ) completed. TT performance was lower (P < 0.05) in SLH, HTN, and HH relative to SLTN (-15.4 ± 9.7, -24.1 ± 16.2, and -33.1 ± 13.4 kJ, respectively). Additionally, the total work completed in HTN and HH was lower (P < 0.05) than that in SLH. In SLH, HTN, and HH, work rate was reduced versus SLTN (P < 0.05) within the first 3 min of exercise and was consistent for the remainder of the bout. No differences (P > 0.05) existed for heart rate or Ratings of Perceived Exertion at the end of exercise among conditions. The decrease in self-paced TT performance in the heat and/or hypobaric hypoxia conditions compared with SLTN conditions resulted from a nearly immediate reduction in work rate that may have been regulated by environmentally induced changes in physiological strain and perception of effort in response to TT exercise.NEW & NOTEWORTHY This is the first known study to examine the combined effects of heat and hypobaric hypoxia on short-duration self-paced cycling time trial performance. Regardless of environmental condition, subjects utilized an even work rate for the entire duration of the time trial. The presence of both environmental stressors led to a greater performance impairment than heat or hypobaric hypoxia alone, and the performance decrement stemmed from an early reduction of work rate.
Collapse
Affiliation(s)
- Karleigh E Bradbury
- Thermal and Mountain Medicine Division, US Army Research Institute of Environmental Medicine, Natick, Massachusetts
| | - Kirsten E Coffman
- Thermal and Mountain Medicine Division, US Army Research Institute of Environmental Medicine, Natick, Massachusetts
| | - Katherine M Mitchell
- Thermal and Mountain Medicine Division, US Army Research Institute of Environmental Medicine, Natick, Massachusetts
| | - Adam J Luippold
- Thermal and Mountain Medicine Division, US Army Research Institute of Environmental Medicine, Natick, Massachusetts
| | - Charles S Fulco
- Thermal and Mountain Medicine Division, US Army Research Institute of Environmental Medicine, Natick, Massachusetts
| | - Robert W Kenefick
- Thermal and Mountain Medicine Division, US Army Research Institute of Environmental Medicine, Natick, Massachusetts
| |
Collapse
|
9
|
Van Cutsem J, Roelands B, De Pauw K, Meeusen R, Marcora S. Subjective thermal strain impairs endurance performance in a temperate environment. Physiol Behav 2019; 202:36-44. [PMID: 30658064 DOI: 10.1016/j.physbeh.2019.01.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Revised: 12/23/2018] [Accepted: 01/12/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE The aim of this study was to test the hypothesis that subjective thermal strain can reduce endurance performance independently from the general physiological strain normally associated with impaired endurance performance in the heat. METHODS In 20 °C and 44% relative humidity, 12 endurance-trained athletes (1♀ 11♂; mean ± SD; age: 27 ± 6 y; VO2max: 61 ± 6 ml/kg/min) performed a time to exhaustion (TTE) test in two different experimental conditions: with an electric heat pad applied to the subjects' upper back (HP) and control (CON: without heat pad). In both conditions, subjects cycled to volitional exhaustion at 70% of their VO2max. Cardiorespiratory, metabolic, thermoregulatory and perceptual responses were measured throughout the TTE test and compared at 0%, 50% and 100% isotime and at exhaustion. RESULTS TTE was reduced by 9% in HP (2092 ± 305 s) compared to CON (2292 ± 344 s; p = .023). The main effect of condition on thermal discomfort at isotime (p = .002), the effect of condition on thermal sensation at 0% isotime (p = .004) and the condition by isotime interaction on rating of perceived exertion (p = .036) indicated higher subjective thermal strain in HP compared to CON. None of the measured cardiorespiratory, metabolic and thermoregulatory variables differed significantly between conditions. CONCLUSION Our novel experimental manipulation (HP) was able to induce significant subjective thermal strain and reduce endurance performance in a temperate environment without inducing the general physiological strain normally associated with impaired endurance performance in the heat. These results suggest that subjective thermal strain is an important and independent mediator of the heat-induced impairment in endurance performance.
Collapse
Affiliation(s)
- Jeroen Van Cutsem
- Human Physiology Research Group, Vrije Universiteit Brussel, Brussel, Belgium; Endurance Research Group, School of Sport and Exercise Sciences, University of Kent, Canterbury, United Kingdom
| | - Bart Roelands
- Human Physiology Research Group, Vrije Universiteit Brussel, Brussel, Belgium
| | - Kevin De Pauw
- Human Physiology Research Group, Vrije Universiteit Brussel, Brussel, Belgium
| | - Romain Meeusen
- Human Physiology Research Group, Vrije Universiteit Brussel, Brussel, Belgium
| | - Samuele Marcora
- Endurance Research Group, School of Sport and Exercise Sciences, University of Kent, Canterbury, United Kingdom; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy.
| |
Collapse
|
10
|
MacRae BA, Annaheim S, Spengler CM, Rossi RM. Skin Temperature Measurement Using Contact Thermometry: A Systematic Review of Setup Variables and Their Effects on Measured Values. Front Physiol 2018. [PMID: 29441024 DOI: 10.3389/fphys.2018.00029, 10.3389/fpls.2018.00029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Background: Skin temperature (Tskin) is commonly measured using Tskin sensors affixed directly to the skin surface, although the influence of setup variables on the measured outcome requires clarification. Objectives: The two distinct objectives of this systematic review were (1) to examine measurements from contact Tskin sensors considering equilibrium temperature and temperature disturbance, sensor attachments, pressure, environmental temperature, and sensor type, and (2) to characterise the contact Tskin sensors used, conditions of use, and subsequent reporting in studies investigating sports, exercise, and other physical activity. Data sources and study selection: For the measurement comparison objective, Ovid Medline and Scopus were used (1960 to July 2016) and studies comparing contact Tskin sensor measurements in vivo or using appropriate physical models were included. For the survey of use, Ovid Medline was used (2011 to July 2016) and studies using contact temperature sensors for the measurement of human Tskinin vivo during sport, exercise, and other physical activity were included. Study appraisal and synthesis methods: For measurement comparisons, assessments of risk of bias were made according to an adapted version of the Cochrane Collaboration's risk of bias tool. Comparisons of temperature measurements were expressed, where possible, as mean difference and 95% limits of agreement (LoA). Meta-analyses were not performed due to the lack of a common reference condition. For the survey of use, extracted information was summarised in text and tabular form. Results: For measurement comparisons, 21 studies were included. Results from these studies indicated minor (<0.5°C) to practically meaningful (>0.5°C) measurement bias within the subgroups of attachment type, applied pressure, environmental conditions, and sensor type. The 95% LoA were often within 1.0°C for in vivo studies and 0.5°C for physical models. For the survey of use, 172 studies were included. Details about Tskin sensor setup were often poorly reported and, from those reporting setup information, it was evident that setups widely varied in terms of type of sensors, attachments, and locations used. Conclusions: Setup variables and conditions of use can influence the measured temperature from contact Tskin sensors and thus key setup variables need to be appropriately considered and consistently reported.
Collapse
Affiliation(s)
- Braid A MacRae
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland.,Exercise Physiology Lab, Institute of Human Movement Sciences and Sport, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Simon Annaheim
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
| | - Christina M Spengler
- Exercise Physiology Lab, Institute of Human Movement Sciences and Sport, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.,Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland
| | - René M Rossi
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
| |
Collapse
|
11
|
MacRae BA, Annaheim S, Spengler CM, Rossi RM. Skin Temperature Measurement Using Contact Thermometry: A Systematic Review of Setup Variables and Their Effects on Measured Values. Front Physiol 2018; 9:29. [PMID: 29441024 PMCID: PMC5797625 DOI: 10.3389/fphys.2018.00029] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 01/09/2018] [Indexed: 11/13/2022] Open
Abstract
Background: Skin temperature (Tskin) is commonly measured using Tskin sensors affixed directly to the skin surface, although the influence of setup variables on the measured outcome requires clarification. Objectives: The two distinct objectives of this systematic review were (1) to examine measurements from contact Tskin sensors considering equilibrium temperature and temperature disturbance, sensor attachments, pressure, environmental temperature, and sensor type, and (2) to characterise the contact Tskin sensors used, conditions of use, and subsequent reporting in studies investigating sports, exercise, and other physical activity. Data sources and study selection: For the measurement comparison objective, Ovid Medline and Scopus were used (1960 to July 2016) and studies comparing contact Tskin sensor measurements in vivo or using appropriate physical models were included. For the survey of use, Ovid Medline was used (2011 to July 2016) and studies using contact temperature sensors for the measurement of human Tskinin vivo during sport, exercise, and other physical activity were included. Study appraisal and synthesis methods: For measurement comparisons, assessments of risk of bias were made according to an adapted version of the Cochrane Collaboration's risk of bias tool. Comparisons of temperature measurements were expressed, where possible, as mean difference and 95% limits of agreement (LoA). Meta-analyses were not performed due to the lack of a common reference condition. For the survey of use, extracted information was summarised in text and tabular form. Results: For measurement comparisons, 21 studies were included. Results from these studies indicated minor (<0.5°C) to practically meaningful (>0.5°C) measurement bias within the subgroups of attachment type, applied pressure, environmental conditions, and sensor type. The 95% LoA were often within 1.0°C for in vivo studies and 0.5°C for physical models. For the survey of use, 172 studies were included. Details about Tskin sensor setup were often poorly reported and, from those reporting setup information, it was evident that setups widely varied in terms of type of sensors, attachments, and locations used. Conclusions: Setup variables and conditions of use can influence the measured temperature from contact Tskin sensors and thus key setup variables need to be appropriately considered and consistently reported.
Collapse
Affiliation(s)
- Braid A. MacRae
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
- Exercise Physiology Lab, Institute of Human Movement Sciences and Sport, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Simon Annaheim
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
| | - Christina M. Spengler
- Exercise Physiology Lab, Institute of Human Movement Sciences and Sport, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
- Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland
| | - René M. Rossi
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
| |
Collapse
|
12
|
Ulrich S, Schneider SR, Bloch KE. Effect of hypoxia and hyperoxia on exercise performance in healthy individuals and in patients with pulmonary hypertension: a systematic review. J Appl Physiol (1985) 2017; 123:1657-1670. [PMID: 28775065 DOI: 10.1152/japplphysiol.00186.2017] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Exercise performance is determined by oxygen supply to working muscles and vital organs. In healthy individuals, exercise performance is limited in the hypoxic environment at altitude, when oxygen delivery is diminished due to the reduced alveolar and arterial oxygen partial pressures. In patients with pulmonary hypertension (PH), exercise performance is already reduced near sea level due to impairments of the pulmonary circulation and gas exchange, and, presumably, these limitations are more pronounced at altitude. In studies performed near sea level in healthy subjects, as well as in patients with PH, maximal performance during progressive ramp exercise and endurance of submaximal constant-load exercise were substantially enhanced by breathing oxygen-enriched air. Both in healthy individuals and in PH patients, these improvements were mediated by a better arterial, muscular, and cerebral oxygenation, along with a reduced sympathetic excitation, as suggested by the reduced heart rate and alveolar ventilation at submaximal isoloads, and an improved pulmonary gas exchange efficiency, especially in patients with PH. In summary, in healthy individuals and in patients with PH, alterations in the inspiratory Po2 by exposure to hypobaric hypoxia or normobaric hyperoxia reduce or enhance exercise performance, respectively, by modifying oxygen delivery to the muscles and the brain, by effects on cardiovascular and respiratory control, and by alterations in pulmonary gas exchange. The understanding of these physiological mechanisms helps in counselling individuals planning altitude or air travel and prescribing oxygen therapy to patients with PH.
Collapse
Affiliation(s)
- Silvia Ulrich
- Pulmonary Division and Center for Human Integrative Physiology, University of Zurich , Zurich , Switzerland
| | - Simon R Schneider
- Pulmonary Division and Center for Human Integrative Physiology, University of Zurich , Zurich , Switzerland
| | - Konrad E Bloch
- Pulmonary Division and Center for Human Integrative Physiology, University of Zurich , Zurich , Switzerland
| |
Collapse
|
13
|
VAN CUTSEM JEROEN, DE PAUW KEVIN, BUYSE LUK, MARCORA SAMUELE, MEEUSEN ROMAIN, ROELANDS BART. Effects of Mental Fatigue on Endurance Performance in the Heat. Med Sci Sports Exerc 2017; 49:1677-1687. [DOI: 10.1249/mss.0000000000001263] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
14
|
Verbickas V, Kamandulis S, Snieckus A, Venckunas T, Baranauskiene N, Brazaitis M, Satkunskiene D, Unikauskas A, Skurvydas A. Serum brain‐derived neurotrophic factor and interleukin‐6 response to high‐volume mechanically demanding exercise. Muscle Nerve 2017; 57:E46-E51. [DOI: 10.1002/mus.25687] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Revised: 04/21/2017] [Accepted: 05/07/2017] [Indexed: 12/23/2022]
Affiliation(s)
- Vaidas Verbickas
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Sigitas Kamandulis
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Audrius Snieckus
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Tomas Venckunas
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Neringa Baranauskiene
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Marius Brazaitis
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Danguole Satkunskiene
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| | - Alvydas Unikauskas
- Department of Laboratory Medicine, Medical AcademyLithuanian University of Health SciencesMickeviciaus 9, Kaunas Lithuania
| | - Albertas Skurvydas
- Institute of Sports Science and InnovationLithuanian Sports UniversityKaunas, Lithuania, Sporto 6, LT 44221, Kaunas Lithuania
| |
Collapse
|
15
|
Lloyd A, Havenith G. Interactions in human performance: An individual and combined stressors approach. Temperature (Austin) 2016; 3:514-517. [PMID: 28090553 PMCID: PMC5198808 DOI: 10.1080/23328940.2016.1189991] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Affiliation(s)
- Alex Lloyd
- Environmental Ergonomics Research Center, Design School Loughborough University , Loughborough, UK
| | - George Havenith
- Environmental Ergonomics Research Center, Design School Loughborough University , Loughborough, UK
| |
Collapse
|
16
|
PÉRIARD JULIEND, RACINAIS SÉBASTIEN. Performance and Pacing during Cycle Exercise in Hyperthermic and Hypoxic Conditions. Med Sci Sports Exerc 2016; 48:845-53. [DOI: 10.1249/mss.0000000000000839] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
17
|
Lloyd A, Raccuglia M, Hodder S, Havenith G. Interaction between environmental temperature and hypoxia on central and peripheral fatigue during high-intensity dynamic knee extension. J Appl Physiol (1985) 2016; 120:567-79. [PMID: 26769955 DOI: 10.1152/japplphysiol.00876.2015] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Accepted: 01/06/2016] [Indexed: 11/22/2022] Open
Abstract
This study investigated causative factors behind the expression of different interaction types during exposure to multistressor environments. Neuromuscular fatigue rates and time to exhaustion (TTE) were investigated in active men (n = 9) exposed to three climates [5 °C, 50% relative humidity (rh); 23 °C, 50% rh; and 42 °C, 70% rh] at two inspired oxygen fractions (0.209 and 0.125 FiO2; equivalent attitude = 4,100 m). After a 40-min rest in the three climatic conditions, participants performed constant-workload (high intensity) knee extension exercise until exhaustion, with brief assessments of neuromuscular function every 110 s. Independent exposure to cold, heat, and hypoxia significantly (P < 0.01) reduced TTE from thermoneutral normoxia (reductions of 190, 405, and 505 s from 915 s, respectively). The TTE decrease was consistent with a faster rate of peripheral fatigue development (P < 0.01) compared with thermoneutral normoxia (increase of 1.6, 3.1, and 4.9%/min from 4.1%/min, respectively). Combined exposure to hypoxic-cold resulted in an even greater TTE reduction (-589 s), likely due to an increase in the rate of peripheral fatigue development (increased by 7.6%/min), but this was without significant interaction between stressors (P > 0.198). In contrast, combined exposure to hypoxic heat reduced TTE by 609 s, showing a significant antagonistic interaction (P = 0.003) similarly supported by an increased rate of peripheral fatigue development (which increased by 8.3%/min). A small decline (<0.4%/min) in voluntary muscle activation was observed only in thermoneutral normoxia. In conclusion, interaction type is influenced by the impact magnitude of the effect of the individual stressors' effect on exercise capacity, whereby the greater the effect of stressors, the greater the probability that one stressor will be abolished by the other. This indicates that humans respond to severe and simultaneous physiological strains on the basis of a worst-strain-takes-precedence principle.
Collapse
Affiliation(s)
- Alex Lloyd
- Environmental Ergonomics Research Centre, Loughborough University, Loughborough, United Kingdom
| | - Margherita Raccuglia
- Environmental Ergonomics Research Centre, Loughborough University, Loughborough, United Kingdom
| | - Simon Hodder
- Environmental Ergonomics Research Centre, Loughborough University, Loughborough, United Kingdom
| | - George Havenith
- Environmental Ergonomics Research Centre, Loughborough University, Loughborough, United Kingdom
| |
Collapse
|
18
|
Alomari MA, Khabour OF, Maikano A, Alawneh K. Vascular function and brain-derived neurotrophic factor: The functional capacity factor. Vasc Med 2015; 20:518-26. [PMID: 26285588 DOI: 10.1177/1358863x15598390] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Brain-derived neurotrophic factor (BDNF) is essential for neurocognitive function. This study aims at establishing a plausible link between level of serum BDNF, functional capacity (FC), and vascular function in 181 young (age 25.5±9.1 years old), apparently healthy adults. Fasting blood samples were drawn from participants' antecubital veins into plain glass tubes while they were in a sitting position to evaluate serum BDNF using enzyme-linked immunosorbent assay (ELISA). Mercury-in-silastic strain-gauge plethysmography was used to determine arterial function indices, blood flow and vascular resistance at rest and following 5 minutes of arterial ischemia. The 6-minute walk distance (6MWD) test was used to determine FC, according to the American Thoracic Society Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories guidelines. It was conducted in an enclosed corridor on a flat surface with a circular track 33 meters long. The walking course was demarcated with bright colored cones. The 6MWD correlated with BDNF (r=0.3, p=0.000), as well as with forearm blood inflow (r=0.5, p=0.000) and vascular resistance (r = -0.4, p=0.000). Subsequent comparison showed that BDNF and blood inflow were greater (p<0.05) while vascular resistance was less (p<0.05) in participants who achieved a longer 6MWD. Similarly, BDNF correlated with forearm blood inflow (r=0.4, p=0.000) and vascular resistance (r = -0.4, p=0.000). Subsequent comparison showed improved vascular function (p<0.05) in the participants with greater BDNF. In conclusion, these findings might suggest that improved vascular function in individuals with greater FC is mediated, at least partially, by an enhanced serum BDNF level.
Collapse
Affiliation(s)
- Mahmoud A Alomari
- Division of Physical Therapy, Department of Rehabilitation Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Omar F Khabour
- Department of Medical Laboratory Sciences, Jordan University of Science and Technology, Irbid, Jordan Department of Biology, Faculty of Science, Taibah University, Medina, Saudi Arabia
| | - Abubakar Maikano
- Department of Medical Laboratory Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Khaldoon Alawneh
- Department of Internal Medicine, Faculty of Medicine, Jordan University of Science and Technology, Irbid, Jordan Division of Rheumatology, Department of Medicine, King Abdulla Hospital, Irbid, Jordan
| |
Collapse
|