1
|
Davila DG, Helm MC, Pourladian IS, Frelich MJ, Kastenmeier AS, Gould JC, Goldblatt MI. Improved immediate postoperative pain following laparoscopic inguinal herniorrhaphy using self-adhering mesh. Surg Endosc 2017; 32:1160-1164. [DOI: 10.1007/s00464-017-5787-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 07/28/2017] [Indexed: 11/30/2022]
|
2
|
Kroese LF, van Eeghem LHA, Verhelst J, Jeekel J, Kleinrensink GJ, Lange JF. Long term results of open complex abdominal wall hernia repair with self-gripping mesh: A retrospective cohort study. Int J Surg 2017; 44:255-259. [PMID: 28689863 DOI: 10.1016/j.ijsu.2017.07.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 07/03/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND In case of complex ventral hernias, Rives-Stoppa and component separation technique are considered as favourable treatment techniques. However, mesh-related complications like recurrence, infection and chronic pain are still a common problem after mesh repair. Previous studies have reported promising results of the use of a self-gripping mesh (ProGrip™) in incisional hernia repair. This study aimed to evaluate the long term results of this mesh for complex ventral hernia treatment. MATERIALS AND METHODS Patients with complex ventral hernia undergoing repair between June 2012 and June 2015, using the ProGrip™-mesh in retromuscular position, were included. All patients visited the outpatient clinic to evaluate short term complications and recurrence. After at least one year, telephone interviews were conducted to evaluate long term results. RESULTS A total of 46 patients (median age 59 years) were included. 40 patients (87%) were diagnosed with incisional hernia. Seven patients (18%) had incisional hernia combined with another hernia. Four patients (8.7%) had an umbilical hernia, one patient (2.2%) had an epigastric hernia and one patient (2.2%) had rectus diastasis. 39 patients completed follow-up. Median follow-up was 25 months (IQR: 19-35 months). 28 patients (72%) did not report any complaints. Nine patients reported pain (average VAS of 1.7). Two patients developed a recurrence requiring reoperation. One patient developed mesh infection requiring reoperation. CONCLUSION Long term results of the use of a self-gripping mesh for complex abdominal wall hernias show a low recurrence rate, even in complex hernia cases. This makes the mesh a good choice in this difficult patient group.
Collapse
Affiliation(s)
- Leonard F Kroese
- Erasmus University Medical Center Rotterdam, Department of Surgery, The Netherlands.
| | | | - Joost Verhelst
- Erasmus University Medical Center Rotterdam, Department of Surgery, The Netherlands
| | - Johannes Jeekel
- Erasmus University Medical Center Rotterdam, Department of Neuroscience, The Netherlands
| | - Gert-Jan Kleinrensink
- Erasmus University Medical Center Rotterdam, Department of Neuroscience, The Netherlands
| | - Johan F Lange
- Erasmus University Medical Center Rotterdam, Department of Surgery, The Netherlands; Havenziekenhuis Rotterdam, Department of Surgery, The Netherlands
| |
Collapse
|
3
|
Molegraaf M, Lange J, Wijsmuller A. Uniformity of Chronic Pain Assessment after Inguinal Hernia Repair: A Critical Review of the Literature. Eur Surg Res 2016; 58:1-19. [PMID: 27577699 DOI: 10.1159/000448706] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 07/26/2016] [Indexed: 12/16/2022]
Abstract
BACKGROUND Chronic postoperative inguinal pain (CPIP) is the most common long-term complication of inguinal hernia repair. As such procedures are routinely performed, CPIP can be considered a significant burden to global health care. Therefore, adequate preventative measures relevant to surgical practice are investigated. However, as no gold standard research approach is currently available, study and outcome measures differ between studies. The current review aims to provide a qualitative analysis of the literature to seek out if outcomes of CPIP are valid and comparable, facilitating recommendations on the best approach to preventing CPIP. METHODS A systematic review of recent studies investigating CPIP was performed, comprising studies published in 2007-2015. Study designs were analyzed regarding the CPIP definitions applied, the use of validated instruments, the availability of a baseline score, and the existence of a minimal follow-up of 12 months. RESULTS Eighty eligible studies were included. In 48 studies, 22 different definitions of CPIP were identified, of which the definition provided by the International Association for the Study of Pain was applied most often. Of the studies included, 53 (66%) used 33 different validated instruments to quantify CPIP. There were 32 studies (40%) that assessed both pain intensity (PI) and quality of life (QOL) with validated tools, 41% and 4% had a validated assessment of only PI or QOL, respectively, and 15% lacked a validated assessment. The visual analog scale and the Short Form 36 (SF36) were most commonly used for measuring PI (73%) and QOL (19%). Assessment of CPIP was unclear in 15% of the studies included. A baseline score was assessed in 45% of the studies, and 75% had a follow-up of at least 12 months. CONCLUSION The current literature addressing CPIP after inguinal hernia repair has a variable degree of quality and lacks uniformity in outcome measures. Proper comparison of the study results to provide conclusive recommendations for preventive measures against CPIP therefore remains difficult. These findings reaffirm the need for a uniform and validated assessment with uniform reporting of outcomes to improve the burden that CPIP poses to a significant surgical patient population.
Collapse
Affiliation(s)
- Marijke Molegraaf
- Department of Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands
| | | | | |
Collapse
|
4
|
Fischer SC, Levy O, Kroner E, Hensel R, Karp JM, Arzt E. Bioinspired polydimethylsiloxane-based composites with high shear resistance against wet tissue. J Mech Behav Biomed Mater 2016; 61:87-95. [DOI: 10.1016/j.jmbbm.2016.01.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Accepted: 01/18/2016] [Indexed: 11/25/2022]
|
5
|
|
6
|
Guillaume O, Teuschl AH, Gruber-Blum S, Fortelny RH, Redl H, Petter-Puchner A. Emerging Trends in Abdominal Wall Reinforcement: Bringing Bio-Functionality to Meshes. Adv Healthc Mater 2015; 4:1763-89. [PMID: 26111309 DOI: 10.1002/adhm.201500201] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 05/12/2015] [Indexed: 12/19/2022]
Abstract
Abdominal wall hernia is a recurrent issue world-wide and requires the implantation of over 1 million meshes per year. Because permanent meshes such as polypropylene and polyester are not free of complications after implantation, many mesh modifications and new functionalities have been investigated over the last decade. Indeed, mesh optimization is the focus of intense development and the biomaterials utilized are now envisioned as being bioactive substrates that trigger various physiological processes in order to prevent complications and to promote tissue integration. In this context, it is of paramount interest to review the most relevant bio-functionalities being brought to new meshes and to open new avenues for the innovative development of the next generation of meshes with enhanced properties for functional abdominal wall hernia repair.
Collapse
Affiliation(s)
- Olivier Guillaume
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology; Donaueschingenstraße 13 A-1200 Vienna Austria
- Austrian Cluster for Tissue Regeneration; Donaueschingenstrasse 13 A-1200 Vienna Austria
| | - Andreas Herbert Teuschl
- Austrian Cluster for Tissue Regeneration; Donaueschingenstrasse 13 A-1200 Vienna Austria
- University of Applied Sciences Technikum Wien; Department of Biochemical Engineering; Höchstädtplatz 5 1200 Vienna Austria
| | - Simone Gruber-Blum
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology; Donaueschingenstraße 13 A-1200 Vienna Austria
- Austrian Cluster for Tissue Regeneration; Donaueschingenstrasse 13 A-1200 Vienna Austria
- Department of General Visceral and Oncological Surgery; Wilhelminenspital der Stadt Wien; Montleartstraße 37 A-1171 Vienna Austria
| | - René Hartmann Fortelny
- Austrian Cluster for Tissue Regeneration; Donaueschingenstrasse 13 A-1200 Vienna Austria
- Department of General Visceral and Oncological Surgery; Wilhelminenspital der Stadt Wien; Montleartstraße 37 A-1171 Vienna Austria
| | - Heinz Redl
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology; Donaueschingenstraße 13 A-1200 Vienna Austria
- Austrian Cluster for Tissue Regeneration; Donaueschingenstrasse 13 A-1200 Vienna Austria
| | - Alexander Petter-Puchner
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology; Donaueschingenstraße 13 A-1200 Vienna Austria
- Austrian Cluster for Tissue Regeneration; Donaueschingenstrasse 13 A-1200 Vienna Austria
| |
Collapse
|
7
|
Verhelst J, de Goede B, Kleinrensink GJ, Jeekel J, Lange JF, van Eeghem KHA. Open incisional hernia repair with a self-gripping retromuscular Parietex mesh: a retrospective cohort study. Int J Surg 2014; 13:184-188. [PMID: 25498491 DOI: 10.1016/j.ijsu.2014.11.043] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Revised: 11/11/2014] [Accepted: 11/27/2014] [Indexed: 11/20/2022]
Abstract
INTRODUCTION The Rives-Stoppa and component separation technique are considered to be favourable techniques in the treatment of complex incisional hernias. However, mesh-related complications like chronic pain are still a common problem after mesh repair. As a result, a new self-gripping mesh to omit suture fixation has been developed. This study aimed to evaluate the safety and feasibility of the Parietex™ Progrip self-gripping mesh in retromuscular position for the treatment of incisional hernias. METHODS Patients with incisional hernia who underwent repair between June 2012 and June 2014, using a self-gripping mesh in retromuscular position, were included in the study. All patients visited the outpatient clinic to identify postoperative complications and early recurrence. RESULTS A total of 28 consecutive patients with a median age of 48 years were included in the study. Twenty-two patients (79%) were diagnosed with an incisional hernia, of whom nine (32%) had a recurrence. Six patients (21%) had an incisional hernia combined with another abdominal wall hernia. The median follow-up was 12 weeks (IQR: 8-20 weeks). Twenty-three patients (82%) did not report any pain at their final outpatient clinic visit; two patients (7%) reported mild abdominal pain, and three patients (11%) had moderate abdominal pain. None of the 28 patients developed a recurrence during follow-up. CONCLUSION This is the first study concerning the use of a Parietex™ Progrip mesh placed in retromuscular position. The study shows that it is a safe and feasible prosthesis in incisional hernias repair, as short-term recurrence did not occur and adverse events were limited.
Collapse
Affiliation(s)
- J Verhelst
- Erasmus University Medical Center Rotterdam, Department of Surgery, The Netherlands.
| | - B de Goede
- Erasmus University Medical Center Rotterdam, Department of Surgery, The Netherlands
| | - G J Kleinrensink
- Erasmus University Medical Center Rotterdam, Department of Neuroscience, The Netherlands
| | - J Jeekel
- Erasmus University Medical Center Rotterdam, Department of Neuroscience, The Netherlands
| | - J F Lange
- Erasmus University Medical Center Rotterdam, Department of Surgery, The Netherlands; Havenziekenhuis Rotterdam, Department of Surgery, The Netherlands
| | - K H A van Eeghem
- Havenziekenhuis Rotterdam, Department of Surgery, The Netherlands
| |
Collapse
|
8
|
Lichtenstein technique for inguinal hernia repair using polypropylene mesh fixed with sutures vs. self-fixating polypropylene mesh: a prospective randomized comparative study. Hernia 2014; 18:193-8. [PMID: 24430578 DOI: 10.1007/s10029-013-1211-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2012] [Accepted: 12/30/2013] [Indexed: 10/25/2022]
Abstract
PURPOSE Chronic postoperative pain is probably the most significant complication of tension-free inguinal hernia repair as its presence can considerably affect the life quality of the patient. Different mesh materials and different surgical techniques for mesh fixation have been applied to reduce chronic postoperative pain, with controversial, nevertheless, results. The aim of this prospective randomized study was to evaluate the effect of a relatively new mesh with self-fixating properties, used to repair inguinal hernia with the Lichtenstein technique, on early and chronic postoperative pain. METHODS Between June 2009 and June 2010, 50 patients with primary unilateral inguinal hernia were treated using the Lichtenstein technique. Patients were randomly assigned to receive either a polypropylene mesh, fixed with polypropylene sutures (n = 25; group A), or a self-fixating polypropylene mesh with resorbable polylactic acid microgrips (n = 25; group B). Demographic data were recorded. Early and chronic postoperative pain was evaluated using the visual analog scale (VAS). Duration of surgery, complications, length of hospitalization and recurrence were also recorded. RESULTS No statistical difference was found between the two groups in association to demographic data. Operating time was 53.4 ± 12.5 and 44.4 ± 7.2 min in groups A and B, respectively, and the difference was statistically significant (p < 0.001). No difference was observed between the groups regarding the postoperative complications. The VAS of early postoperative pain was 1.7 ± 1.9 in group A and 1.3 ± 1.6 in group B, with the difference being not statistically significant (p = 0.21). Concerning chronic pain, no remarkable statistically significant difference was observed between the two groups at 3-month, 1- and 2-year follow-up period. At the end of the study, no recurrence was reported in either group. CONCLUSIONS Self-fixating mesh can be safely and effectively used in inguinal hernia repair with the additional advantage of reducing the operative time compared to the classic Lichtenstein technique. However, its use is not accompanied by reduced rates in early or chronic postoperative pain.
Collapse
|
9
|
Zhang C, Li F, Zhang H, Zhong W, Shi D, Zhao Y. Self-gripping versus sutured mesh for inguinal hernia repair: a systematic review and meta-analysis of current literature. J Surg Res 2013; 185:653-60. [DOI: 10.1016/j.jss.2013.07.035] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Revised: 07/04/2013] [Accepted: 07/16/2013] [Indexed: 11/30/2022]
|
10
|
Sajid MS, Farag S, Singh KK, Miles WFA. Systematic review and meta-analysis of published randomized controlled trials comparing the role of self-gripping mesh against suture mesh fixation in patients undergoing open inguinal hernia repair. Updates Surg 2013; 66:189-96. [DOI: 10.1007/s13304-013-0237-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Accepted: 10/08/2013] [Indexed: 10/26/2022]
|
11
|
Jorgensen LN, Sommer T, Assaadzadeh S, Strand L, Dorfelt A, Hensler M, Rosenberg J. Randomized clinical trial of self-gripping mesh versus sutured mesh for Lichtenstein hernia repair. Br J Surg 2012. [DOI: 10.1002/bjs.9006] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Abstract
Background
Many patients develop discomfort after open repair of a groin hernia. It was hypothesized that suture fixation of the mesh is a cause of these symptoms.
Methods
This patient- and assessor-blinded randomized multicentre clinical trial compared a self-gripping mesh (Parietene Progrip®) and sutured mesh for open primary repair of uncomplicated inguinal hernia by the Lichtenstein technique. Patients were assessed before surgery, on the day of operation, and at 1 and 12 months after surgery. The primary endpoint was moderate or severe symptoms after 12 months, including a combination of chronic pain, numbness and discomfort.
Results
The intention-to-treat population comprised 163 patients with self-gripping mesh and 171 with sutured mesh. The 12-month prevalence of moderate or severe symptoms was 17·4 and 20·2 per cent respectively (P = 0·573). There were no significant differences between the groups in postoperative complications (33·7 versus 40·4 per cent; P = 0·215), rate of recurrent hernia within 1 year (1·2 per cent in both groups) or quality of life.
Conclusion
The avoidance of suture fixation using a self-gripping mesh was not accompanied by a reduction in chronic symptoms after inguinal hernia repair. Registration number: NCT00815698 (http://www.clinicaltrials.gov).
Collapse
Affiliation(s)
| | - L N Jorgensen
- Department of Surgery, Bispebjerg Hospital, Copenhagen, Denmark
| | - T Sommer
- Department of Surgery, Randers Hospital, Randers, Copenhagen, Denmark
| | - S Assaadzadeh
- Department of Surgery, Herlev Hospital, University of Copenhagen, Copenhagen, Denmark
| | - L Strand
- Department of Surgery, Frederikshavn Hospital, Frederikshavn, Copenhagen, Denmark
| | - A Dorfelt
- Department of Surgery, Nyborg Hospital, Nyborg, Denmark
| | - M Hensler
- Department of Surgery, Bispebjerg Hospital, Copenhagen, Denmark
| | - J Rosenberg
- Department of Surgery, Herlev Hospital, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
12
|
Chronic pain after open inguinal hernia surgery: suture fixation versus self-adhesive mesh repair. Langenbecks Arch Surg 2012; 397:1215-8. [DOI: 10.1007/s00423-012-0949-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2011] [Accepted: 03/16/2012] [Indexed: 10/28/2022]
|
13
|
Hollinsky C, Patri P, Hollinsky S, Tuchmann A. Mini-incisional laparoscopic surgery (MILS) for inguinal hernia repair*. Eur Surg 2012. [DOI: 10.1007/s10353-011-0068-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|