1
|
Pogorelić Z, Poljak K, Jukić M, Vukojević K. Ultrasonic Scalpel vs. Polymeric Clip Laparoscopic Varicocelectomy in Adolescents with Symptomatic Varicocele. J Clin Med 2024; 13:4322. [PMID: 39124589 PMCID: PMC11313559 DOI: 10.3390/jcm13154322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Revised: 07/16/2024] [Accepted: 07/24/2024] [Indexed: 08/12/2024] Open
Abstract
Background: The aim of this study was to investigate treatment outcomes in adolescents who underwent laparoscopic surgery with an ultrasonic scalpel for symptomatic varicocele compared with adolescents who underwent surgery with a polymer clip. Methods: A total of 270 adolescents with a median age of 16 (interquartile range, IQR 13-17) years were included in the study. Taking into account the laparoscopic varicocelectomy technique used, the patients were divided into two groups. In the first group (n = 151), a polymer clip was used, while in the second group (n = 119), an ultrasonic scalpel was used to resect the spermatic vessels. The primary outcome measure was the effect of the laparoscopic technique used on treatment outcomes (postoperative complications and recurrence rates). Secondary outcomes were the duration of surgery and anesthesia and the length of hospital stay. Results: The duration of the surgical procedure (12 min (IQR 11, 15) versus 15 min (12, 19), p = 0.029) and anesthesia (21.5 min (16, 29.5) versus 28 min (23, 34), p = 0.003) was shorter in the group of adolescents in whom laparoscopic varicocelectomy was performed with an ultrasonic scalpel than in the group in which a polymer clip was used. No statistically significant difference was found between the groups studied in terms of length of hospital stay, recurrence rate (p >0.999), and complications (p = 0.703). There were no cases of testicular atrophy in either group. In the group of patients who underwent laparoscopic varicocelectomy with an ultrasonic scalpel, a slightly higher incidence of hydroceles was found (n = 4, 3.4%) than in the group in which a polymer clip was used (n = 2, 1.3%) (p = 0.410). At six-month follow-up, it was found that the majority of patients showed moderate or significant improvement in the spermogram after laparoscopic varicocelectomy (n = 85, 89.5%). In addition, the subjective discomfort or pain disappeared in the majority of patients (n = 71, 93.4%). The testicular volume increased significantly in 132 adolescents (89.8%). Conclusions: Laparoscopic varicocelectomy with a polymer clip or ultrasonic scalpel is safe and effective in adolescents with symptomatic varicocele. Treatment outcomes after laparoscopic varicocelectomy are the same regardless of whether a polymer clip or an ultrasonic scalpel is used to resect the spermatic vessels. The use of an ultrasonic scalpel for resection of the spermatic vessels shortens the overall duration of surgery and anesthesia.
Collapse
Affiliation(s)
- Zenon Pogorelić
- Department of Surgery, School of Medicine, University of Split, 21000 Split, Croatia
- Department of Pediatric Surgery, University Hospital of Split, 21000 Split, Croatia
| | - Karlo Poljak
- Department of Surgery, School of Medicine, University of Split, 21000 Split, Croatia
| | - Miro Jukić
- Department of Surgery, School of Medicine, University of Split, 21000 Split, Croatia
- Department of Pediatric Surgery, University Hospital of Split, 21000 Split, Croatia
| | - Katarina Vukojević
- Department of Anatomy, Histology and Embryology, School of Medicine, University of Split, 21000 Split, Croatia
| |
Collapse
|
2
|
Oturu K, Ijomah W, Orr A, Verpeaux L, Broadfoot B, Clark S, Devine R. Remanufacturing of single-use medical devices: a case study on cross-border collaboration between the UK and Nigeria. HEALTH AND TECHNOLOGY 2022; 12:273-283. [PMID: 35136709 PMCID: PMC8814787 DOI: 10.1007/s12553-022-00641-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Accepted: 01/21/2022] [Indexed: 11/24/2022]
Abstract
This paper aims to evaluate the current state of the remanufacturing of medical devices, considering the differences between developed and developing countries. With reference to various socio-economic factors, the impact of remanufacturing to sustainability was evaluated and from this, single-use medical devices were deemed to be critical in minimising waste within the medical industry. This is even more critical with increasing use of single-use devices in the Coronavirus disease 2019 (COVID 19) pandemic. It was identified that cleaning is a key consideration for ensuring a safe remanufacturing process that would minimise the risk of infection to patients. Therefore, this process was evaluated and appropriate recommendations made. Although there may be some challenges, further research would be required for integration of the methodology and process outlined into the medical sector.
Collapse
Affiliation(s)
- Kingsley Oturu
- Department of Design Manufacturing & Engineering Management, University of Strathclyde, Strathclyde, Scotland
| | - Winifred Ijomah
- Department of Design Manufacturing & Engineering Management, University of Strathclyde, Strathclyde, Scotland
| | - Andrew Orr
- Department of Design Manufacturing & Engineering Management, University of Strathclyde, Strathclyde, Scotland
| | - Laura Verpeaux
- Department of Design Manufacturing & Engineering Management, University of Strathclyde, Strathclyde, Scotland
| | - Ben Broadfoot
- Department of Mechanical & Aerospace Engineering, University of Strathclyde, Strathclyde, Scotland
| | - Stuart Clark
- Department of Mechanical & Aerospace Engineering, University of Strathclyde, Strathclyde, Scotland
| | - Ryan Devine
- Department of Mechanical & Aerospace Engineering, University of Strathclyde, Strathclyde, Scotland
| |
Collapse
|
3
|
Regulating Environmental Impact of Medical Devices in the United Kingdom—A Scoping Review. PROSTHESIS 2021. [DOI: 10.3390/prosthesis3040033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Medical devices are highly regulated to ensure safety and efficacy of the products and minimize the risk of harm to users and patients. However, the broader impacts of these devices on the environment have scarcely been questioned until recently. The United Kingdom National Health Service intends to achieve a “net zero” emissions service by 2040 and has identified specific targets to achieve through this process. However, medical device manufacturers do not see sufficient incentives to invest in reducing greenhouse gas emissions unless enforced by legislation. Furthermore, there is little evidence on the legislation required to reduce emissions from medical devices. This study addresses the relationship of medical device regulations and the environmental impact of the devices throughout their lifecycle. A scoping review was conducted on academic literature on the topic, followed by a critical review of the current medical device regulations and associated guidelines in the United Kingdom. The challenges to regulating environmental impact of medical devices were identified under seven themes. These challenges were contextualized with the National Health Service target of achieving zero emissions by 2040. The review indicates that current guidelines support single-use disposal of devices and equipment as the best approach to prevent pathogen transmission and landfilling and incineration are the most used waste management strategies. Manufacturers need to be guided and educated on reducing their emissions while ensuring the development of safe and effective devices.
Collapse
|
4
|
Mihanović J, Šikić NL, Mrklić I, Katušić Z, Karlo R, Jukić M, Jerončić A, Pogorelić Z. Comparison of new versus reused Harmonic scalpel performance in laparoscopic appendectomy in patients with acute appendicitis-a randomized clinical trial. Langenbecks Arch Surg 2021; 406:153-162. [PMID: 33241426 DOI: 10.1007/s00423-020-02039-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Accepted: 11/17/2020] [Indexed: 12/21/2022]
Abstract
BACKGROUND The aim of this study was to compare lateral thermal damage of the appendix and clinical outcomes after laparoscopic appendectomy using new versus reused Harmonic scalpels. METHODS A total of 100 consecutive patients with acute appendicitis who underwent laparoscopic appendectomy were enrolled in the two-center, randomized clinical trial. Using a computer random number generator, patients were allocated to new or reused group. Histopathological measurement of lateral thermal damage of the appendiceal base and mesoappendix, speed of transection of the appendiceal base, duration of surgery, subjective rating of device functionality, length of hospital stay, and complications were compared within groups. RESULTS The median lateral thermal damage on the appendiceal base in the new group (N = 49) was 0.2 mm (IQR 0.1-0.2) and 0.1 mm (IQR 0.1-0.3) in the reused group (N = 51) (P = 0.644), while on the mesoappendix for both groups, thermal damage was 0.1 mm (IQR 0.1-0.2) (P = 0.418). The median time required for base transection in both groups was 8 s (IQR 7-9) (P = 0.776). The median duration of surgery was also comparable between the groups (22 min, IQR 20-30 vs 25 min, IQR 21-35; P = 0.233). Two postoperative complications in the new group and one in the reused group were recorded (4% vs 2%; P = 0.536). Surgeons' subjective assessment of the instrument did not reveal significant difference between the groups in all of the investigated categories. CONCLUSIONS The results of our study support the reuse of Harmonic scalpels especially in the settings where economic constraints might hamper access to minimally invasive surgery to a larger number of patients. The results obtained on laparoscopic appendectomy might not be reproducible to other more demanding surgical procedures. TRIAL REGISTRATION ClinicalTrials.gov registry under identifier NCT04226482.
Collapse
Affiliation(s)
- Jakov Mihanović
- Department of Surgery, Zadar General Hospital, Zadar, Croatia
- Department of Health Studies, University of Zadar, Zadar, Croatia
| | - Nataša Lisica Šikić
- Department of Pathology, Forensic Medicine and Cytology, Zadar General Hospital, Zadar, Croatia
| | - Ivana Mrklić
- Department of Pathology, Forensic Medicine and Cytology, University Hospital of Split, Split, Croatia
| | | | - Robert Karlo
- Department of Surgery, Zadar General Hospital, Zadar, Croatia
- Department of Health Studies, University of Zadar, Zadar, Croatia
| | - Miro Jukić
- Department of Surgery, School of Medicine, University of Split, Split, Croatia
- Department of Pediatric Surgery, University Hospital of Split, Spinčićeva 1, 21000, Split, Croatia
| | - Ana Jerončić
- Department of Research in Biomedicine and Health, School of Medicine, University of Split, Split, Croatia
| | - Zenon Pogorelić
- Department of Surgery, School of Medicine, University of Split, Split, Croatia.
- Department of Pediatric Surgery, University Hospital of Split, Spinčićeva 1, 21000, Split, Croatia.
| |
Collapse
|
5
|
Chivukula SR, Lammers S, Wagner J. Assessing organic material on single-use vessel sealing devices: a comparative study of reprocessed and new LigaSure™ devices. Surg Endosc 2020; 35:4539-4549. [PMID: 32909208 PMCID: PMC8263541 DOI: 10.1007/s00464-020-07969-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 08/27/2020] [Indexed: 11/29/2022]
Abstract
Background Reprocessed devices must be thoroughly cleaned prior to sterilization to ensure efficacy of sterilization agents. Many single-use devices are not designed to be thoroughly cleaned. Interlocking design features inherent to LigaSure™ vessel sealing devices may prevent thorough cleaning and promote accumulation of human tissue that cannot be removed. Thus, the aim of this study was to compare industry reprocessed and new LigaSure™ vessel sealing devices for organic material. Methods A total of 168, 84 new and 84 reprocessed, vessel sealing devices were disassembled and inspected for the presence of residual organic matter using visual, microscopic, and chemical analysis. Devices were randomized and test conductors blinded to group membership. Devices were aseptically disassembled and sent through visual inspection. Next, devices were either examined using light microscopy, scanning electron microscopy (SEM) or exposed to a solution that luminesces in the presence of hemoglobin. Additionally, 165 reprocessed devices were sent to a 3rd party lab for sterility testing via direct immersion culture for 14 days. Results Significant amounts of remnant organic material (C, N, O, S, Na, P) were observed with 81/84 reprocessed and 0/84 new devices failing inspection protocols. When tested for the presence of hemoglobin, only 1/12 reprocessed devices passed inspection. SEM of reprocessed devices revealed residues with liquid patterns and diffuse soiling with foreign material. Sterility testing of reprocessed devices revealed a sterility level < 6–3. Conclusions The abundance of material resembling human tissue observed on reprocessed VSDs suggests inadequate cleaning prior to sterilization. Atomic and morphological analyses of the remnant materials suggest that bacterial biofilms could also be present. Additionally, surface degradation and release of reinforcing glass fibers from the device were observed. Devices designed for single use can harbor significant amounts of remnant material that likely interfere with the sterilization process.
Collapse
Affiliation(s)
- Swathi Ramesh Chivukula
- Department of Bioengineering, University of Colorado Denver
- Anschutz Medical Campus, 12705 E. Montview Blvd., Ste. 100, Mail Stop 8607, Aurora, CO, 80045, USA
| | - Steven Lammers
- Department of Bioengineering, University of Colorado Denver
- Anschutz Medical Campus, 12705 E. Montview Blvd., Ste. 100, Mail Stop 8607, Aurora, CO, 80045, USA
| | - Jennifer Wagner
- Department of Bioengineering, University of Colorado Denver
- Anschutz Medical Campus, 12705 E. Montview Blvd., Ste. 100, Mail Stop 8607, Aurora, CO, 80045, USA.
| |
Collapse
|
6
|
Quitzan JG, Singh A, Beaufrere H, Valverde A, Lillie B, Salahshoor M, Bardelcik A, Saleh TM. Evaluation of the performance of an endoscopic 3-mm electrothermal bipolar vessel sealing device intended for single use after multiple use-and-resterilization cycles. Vet Surg 2020; 49 Suppl 1:O120-O130. [PMID: 32053219 DOI: 10.1111/vsu.13396] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 11/22/2019] [Accepted: 01/18/2020] [Indexed: 12/30/2022]
Abstract
OBJECTIVE To evaluate the performance of an endoscopic 3-mm electrothermal bipolar vessel sealing device (EBVS) intended for single use after multiple use-and-resterilization cycles. STUDY DESIGN Ex vivo study. SAMPLE POPULATION Eight 3-mm EBVS handpieces. METHODS Handpieces were subjected to a maximum of 15 cycles of testing, including simulated surgery, sealing and burst pressure testing of porcine carotid arteries, reprocessing, and hydrogen peroxide plasma resterilization. Failure was defined as two sequential vascular seal leakage events occurring at <250 mm Hg. Histological evaluation, maximum external temperature of the jaws, sealing time, tissue adherence, jaw surface characterization, and mechanical deterioration were studied. Failure rate was analyzed by using a Kaplan-Meier curve. Linear and ordinal logistic mixed models were used to analyze sealing time, handpiece jaw temperature, and adherence score. RESULTS Mean ± SD diameter of arteries was 3.22 ± 0.35 mm. Failure was observed starting at cycle 10 and going up to cycle 13 in 37.5% (3/8) of the handpieces. Tissue adherence increased after each cycle (P < .001). Maximum external temperature (79.8°C ± 13.9°C) and sealing time (1.8 ± 0.5 seconds) were not significantly different throughout cycles up to failure. A flatter surface and large scratches were observed microscopically throughout the jaw surface after repeated use and resterilization. CONCLUSION The 3-mm EBVS handpiece evaluated in this study can be considered safe to use for up to nine reuse-and-resterilization cycles. CLINICAL SIGNIFICANCE These data provide the basis for establishing preliminary guidelines for the reuse and hydrogen peroxide plasma resterilization of an endoscopic 3-mm EBVS handpiece.
Collapse
Affiliation(s)
- Juliany Gomes Quitzan
- School of Veterinary Medicine and Animal Science, Sao Paulo State University, Botucatu, Sao Paulo, Brazil.,Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Ontario, Canada
| | - Ameet Singh
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Ontario, Canada
| | - Hugues Beaufrere
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Ontario, Canada
| | - Alexander Valverde
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Ontario, Canada
| | - Brandon Lillie
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Ontario, Canada
| | - Masoomeh Salahshoor
- School of Engineering, College of Engineering and Physical Sciences, University of Guelph, Ontario, Canada
| | - Alexander Bardelcik
- School of Engineering, College of Engineering and Physical Sciences, University of Guelph, Ontario, Canada
| | - Tarek M Saleh
- Department of Biomedical Sciences, Ontario Veterinary College, University of Guelph, Ontario, Canada
| |
Collapse
|
7
|
de Sousa Martins B, Queiroz e Melo J, Logarinho Monteiro J, Rente G, Teixeira Bastos P. Reprocessing of Single-Use Medical Devices: Clinical and Financial Results. PORTUGUESE JOURNAL OF PUBLIC HEALTH 2019. [DOI: 10.1159/000496299] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|