1
|
Hayashi M, Fujita T, Matsushita H. Recurrent laryngeal nerve lymph node dissection with subcomplete sealing using advanced bipolar energy device in minimally invasive esophagectomy. Asian J Endosc Surg 2025; 18:e13406. [PMID: 39520079 DOI: 10.1111/ases.13406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 07/08/2024] [Accepted: 10/27/2024] [Indexed: 11/16/2024]
Abstract
INTRODUCTION Recurrent laryngeal nerve (RLN) palsy is a complication that must be avoided during esophagectomy. While RLN injury is thought to be caused by thermal spread from electric devices, electric devices are useful to avoid bleeding. When dissecting lymph nodes around RLNs, to seal small vessels, we use subcomplete technique with advanced bipolar. We describe our surgical technique, termed the subcomplete sealing technique, in RLN lymph node dissection. MATERIALS AND SURGICAL TECHNIQUE The first step is to perform blunt dissection with forceps on both sides of the esophageal branch near the right RLN. A distance of at least 2 mm from the RLN was preferred. Sealing with advanced bipolar often causes tissue shrinkage, pulling the RLN near the device. To prevent this, sealing should be stopped before reaching completion. Although the sealing was not complete, it was sufficient to seal the small vessels. After subcomplete sealing, the sealed tissues were dissected using laparoscopic scissors. The lymph nodes around left RLN are dissected in the same manner. DISCUSSION A total of 76 patients received esophagectomy with the subcomplete technique. Grade IIIa RLN palsy occurred in three cases (3.95%). Over Grade IIIb RLN palsies did not occur. This subcomplete sealing technique can assist surgeons in performing RLN lymph node dissection without bleeding and increasing the rate of RLN palsy.
Collapse
Affiliation(s)
- Masato Hayashi
- Department of Surgery, Tochigi Cancer Center Hospital, Utsunomiya, Japan
| | - Takeshi Fujita
- Department of Surgery, Tochigi Cancer Center Hospital, Utsunomiya, Japan
| | | |
Collapse
|
2
|
Taniyama Y, Okamoto H, Sato C, Ozawa Y, Ishida H, Unno M, Kamei T. Prevention and Management of Recurrent Laryngeal Nerve Palsy in Minimally Invasive Esophagectomy: Current Status and Future Perspectives. J Clin Med 2024; 13:7611. [PMID: 39768533 PMCID: PMC11678675 DOI: 10.3390/jcm13247611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2024] [Revised: 12/03/2024] [Accepted: 12/11/2024] [Indexed: 01/11/2025] Open
Abstract
Recurrent laryngeal nerve palsy remains a significant complication following minimally invasive esophagectomy for esophageal cancer. Despite advancements in surgical techniques and lymphadenectomy precision, the incidence of recurrent laryngeal nerve palsy has not been improved. Recurrent laryngeal nerve palsy predominantly affects the left side and may lead to unilateral or bilateral vocal cord paralysis, resulting in hoarseness, dysphagia, and an increased risk of aspiration pneumonia. While most cases of recurrent laryngeal nerve palsy are temporary and resolve within 6 to 12 months, some patients may experience permanent nerve dysfunction, severely impacting their quality of life. Prevention strategies, such as nerve integrity monitoring, robotic-assisted minimally invasive esophagectomy, and advanced dissection techniques, aim to minimize nerve injury, though their effectiveness varies. The management of recurrent laryngeal nerve palsy includes voice and swallowing rehabilitation, reinnervation techniques, and, in severe cases, surgical interventions such as thyroplasty and intracordal injection. As recurrent laryngeal nerve palsy can lead to significant postoperative respiratory complications, a multidisciplinary approach involving surgical precision, early detection, and comprehensive rehabilitation is crucial to improving patient outcomes and minimizing long-term morbidity in minimally invasive esophagectomy. This review article aims to inform esophageal surgeons and other clinicians about strategies for the prevention and management of recurrent laryngeal nerve palsy in esophagectomy.
Collapse
Affiliation(s)
- Yusuke Taniyama
- Department of Surgery, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Miyagi, Japan
| | | | | | | | | | | | | |
Collapse
|
3
|
Morikawa T, Hamamoto S, Gonda M, Taguchi K, Unno R, Torii K, Isogai M, Kawase K, Nagai T, Iwatsuki S, Etani T, Naiki T, Okada A, Yasui T. Evaluation of thermal effects of surgical energy devices: ex vivo study. Sci Rep 2024; 14:27365. [PMID: 39521906 PMCID: PMC11550423 DOI: 10.1038/s41598-024-78624-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Accepted: 11/04/2024] [Indexed: 11/16/2024] Open
Abstract
This study evaluated the direct and indirect thermal effects of various surgical energy devices using an ex-vivo model. Two types of three devices were evaluated: ENSEAL™ X1 Curved Jaw Tissue Sealer (X1) and ENSEAL™ G2 Curved Tissue Sealer (G2) as vessel sealing systems (VSSs), and HARMONIC® HD1000i Shears (HA) as an ultrasonic activating device (USAD). Each device was activated once under DRY or WET conditions. The tissue's maximum temperature (MT), steam MT surrounding the activation site, and steam spread area (SSA) were measured. Under WET conditions, the median MT of a porcine common carotid artery at 1 mm from the activation site by X1, G2, and HA were 84.4, 83.3, and 50.5 °C, respectively. The direct thermal effect of HA was the lowest among the three devices. VSSs showed higher tissue MT under WET conditions compared with DRY conditions. Conversely, USAD showed the opposite trend. G2 demonstrated a significantly higher MT than X1 and HA (P < 0.05). A significant decrease in SSA was observed with decreasing grasping range. In conclusion, VSSs generated higher temperatures than USAD, especially under WET conditions. Surgeons should consider minimizing thermal effects by creating DRY conditions or performing gradual incisions when using VSS devices.
Collapse
Affiliation(s)
- Toshiharu Morikawa
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Shuzo Hamamoto
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan.
| | - Masakazu Gonda
- Department of Urology, Nagoya City University Midori Municipal Hospital, Nagoya, Japan
| | - Kazumi Taguchi
- Department of Urology, Nagoya City University East Medical Center, Nagoya, Japan
| | - Rei Unno
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Koei Torii
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Masahiko Isogai
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Kengo Kawase
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Takashi Nagai
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Shoichiro Iwatsuki
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Toshiki Etani
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Taku Naiki
- Department of Urology, Nagoya City University West Medical Center, Nagoya, Japan
| | - Atsushi Okada
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Takahiro Yasui
- Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| |
Collapse
|
4
|
Kaku K, Kubo S, Sato Y, Mei T, Noguchi H, Okabe Y, Nakamura M. Efficacy and Safety Evaluation of Energy Devices in Bench Surgery for Pancreas Transplantation. J Surg Res 2024; 298:149-159. [PMID: 38608426 DOI: 10.1016/j.jss.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 03/12/2024] [Accepted: 03/13/2024] [Indexed: 04/14/2024]
Abstract
INTRODUCTION Bench surgery for the preparation of deceased donor pancreatic grafts is labor-intensive and time-consuming. We hypothesized that energy devices could be used during bench surgery to decrease the bench surgery time. However, because bench surgery has two unique characteristics, wet conditions and no blood flow in the vessels, it is necessary to verify the safety and efficacy under such conditions. METHODS In an animal tissue model, we validated both ultrasonic and bipolar energy devices: Harmonic Shears and the LigaSure (LS) vessel-sealing device by evaluating heat spread and pressure resistance under bench surgery conditions. In a clinical evaluation of the LS, we compared the outcomes of 22 patients in two different bench surgery groups: with and without the use of the LS. RESULTS Clinically, the bench surgery time was significantly shorter in the LS group than that in the conventional group (P < 0.001). In the animal tissue experiments, the highest temperature in bench surgery conditions was 60.4°C after 1 s at a 5-mm distance in the LS group. Pressure resistance of ≥ 750 mmHg was achieved in almost all trials in both veins and arteries, with no difference between Harmonic Shears and LS. There was more surgical smoke visually in bench conditions versus in dry conditions and under half bite versus full bite conditions. CONCLUSIONS The encouraging results of our exploratory clinical and animal studies of the energy devices suggest that they may be useful in the setting of bench surgery.
Collapse
Affiliation(s)
- Keizo Kaku
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Shinsuke Kubo
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yu Sato
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Takanori Mei
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Hiroshi Noguchi
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yasuhiro Okabe
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Masafumi Nakamura
- Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
| |
Collapse
|
5
|
Hirahara N, Matsubara T, Hayashi H, Tajima Y. Features and applications of energy devices for prone robot-assisted minimally invasive esophagectomy: a narrative review. J Thorac Dis 2022; 14:3606-3612. [PMID: 36245588 PMCID: PMC9562513 DOI: 10.21037/jtd-22-559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 08/26/2022] [Indexed: 12/02/2022]
Abstract
BACKGROUND AND OBJECTIVE Robot-assisted surgery is particularly useful in esophagectomy for esophageal cancer because robotic systems have high-resolution three-dimensional imaging, tremor filtering, and articulated instruments. This review article focuses on the applications and limitations of surgical devices in robot-assisted minimally invasive esophagectomy (RAMIE). METHODS A narrative search of Medline was performed for articles published using the keywords "robot-assisted esophagectomy", "technique", "postoperative complication", and "short-term outcomes". KEY CONTENTS AND FINDINGS Monopolar scissors: these devices with a sharp tip have an articulating function that allows for fast, sharp dissection without an electrical source. However, scissor-type devices cannot compress the organ, and their hemostatic ability is rather weak. Maryland bipolar forceps: the device has a very thin tip that allows for accurate dissection as well as stronger hemostatic ability by closing the forceps to compress tissues and applying electric current. The disadvantage is longer operation time because the forceps need to be constantly closed and reopened. Long Maryland bipolar grasper: the tip of the long Maryland bipolar grasper is slightly blunt and has the advantage of versatility because it can grip the tissue more delicately. Ultrasonic scalpel: the device can transect tissues speedily without bleeding, shortening operation time, but lacks articulating function. Although thermal spread to the surroundings is relatively narrow, activation time increases with the amount of tissue to be grasped; this raises the temperature above that of the vessel sealer. Vessel sealer: the device is one of the most powerful hemostatic energy devices, based on bipolar electrodes. The articulating jaws on both sides are more suited for sharp transection rather than meticulous dissection because of its powerful hemostatic force and blunt tip. It is also important to note that the vessel sealer produces widespread high-temperature steam. SynchroSeal: the device offers fast activation time, and due to the tip of the device being finely divided, which requires relatively precise manipulation. CONCLUSIONS Robot-assisted surgery reduces the limitations of conventional endoscopic surgery by offering stable high-resolution three-dimensional imaging, tremor filtering, and articulated instruments. It is important to understand and exploit the advantages of energy devices suitable for RAMIE.
Collapse
Affiliation(s)
- Noriyuki Hirahara
- Department of Digestive and General Surgery, Shimane University Faculty of Medicine, Izumo, Japan
| | - Takeshi Matsubara
- Department of Digestive and General Surgery, Shimane University Faculty of Medicine, Izumo, Japan
| | - Hikota Hayashi
- Department of Digestive and General Surgery, Shimane University Faculty of Medicine, Izumo, Japan
| | - Yoshitsugu Tajima
- Department of Digestive and General Surgery, Shimane University Faculty of Medicine, Izumo, Japan
| |
Collapse
|
6
|
Pace-Asciak P, Russell JO, Tufano RP. Improving Voice Outcomes after Thyroid Surgery and Ultrasound-Guided Ablation Procedures. Front Surg 2022; 9:882594. [PMID: 35599805 PMCID: PMC9114795 DOI: 10.3389/fsurg.2022.882594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 04/11/2022] [Indexed: 11/13/2022] Open
Abstract
The field of endocrine surgery has expanded from the traditional open neck approach to include remote access techniques as well as minimally invasive approaches for benign and malignant thyroid nodules. In experienced hands and with careful patient selection, each approach is considered safe, however complications can and do exist. Post-operative dysphonia can have serious consequences to the patient by affecting quality of life and ability to function at work and in daily life. Given the significance of post-procedural dysphonia, we review the surgical and non-surgical techniques for minimizing and treating recurrent laryngeal nerve injury that can be utilized with the traditional open neck approach, remote access thyroidectomy, or minimally invasive thermal ablation.
Collapse
Affiliation(s)
- Pia Pace-Asciak
- Department of Otolaryngology – Head and Neck Surgery, University of Toronto, Toronto, Canada
| | - Jon O. Russell
- Department of Otolaryngology – Head and Neck Surgery, Johns Hopkins University, Baltimore, Maryland, United States
| | - Ralph P. Tufano
- Sarasota Memorial Health Care System Multidisciplinary Thyroid and Parathyroid Center, Sarasota, Florida, United States
- Correspondence: Ralph P. Tufano
| |
Collapse
|
7
|
Yu X, Li Y, Liu C, Jiang Y, Liu Z, He Q, Wang Y, Wang P. Effects of Intraoperative Neural Tunnel in Protecting Recurrent Laryngeal Nerve: Experiences in Open, Trans Breast, and Transoral Endoscopic Thyroidectomy. Front Oncol 2022; 12:779621. [PMID: 35280753 PMCID: PMC8904970 DOI: 10.3389/fonc.2022.779621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Accepted: 01/31/2022] [Indexed: 12/04/2022] Open
Abstract
Background Energy-based devices (EBDs) increase the risks of thermal nerve injuries. This study aimed to introduce a surgical strategy of intraoperative neural tunnel protecting (INTP) for evaluating the effect in reducing the incidence of recurrent laryngeal nerve (RLN) damage in open, trans breast, and transoral endoscopic thyroidectomy. Methods INTP strategy was introduced: a tunnel was established and protected by endoscopic gauze along the direction of the nerve. A total of 165, 94, and 200 patients with papillary thyroid carcinoma (PTC) were to use INTP in respectively open, trans breast, and transoral endoscopic thyroidectomy as the INTP group. Additionally, 150, 95, and 225 patients who received the same methods without INTP were enrolled in the control group. Ipsilateral thyroidectomy or total thyroidectomy, and central compartment dissection were performed on the enrolled patients. Results Clinicopathologic characteristics, surgical outcomes, and surgical complications were similar between the INTP group and the control group in open, trans breast, and transoral endoscopic thyroidectomy. The incidences of electromyography (EMG) changes in the INTP group were lower as compared to the control group in trans breast endoscopic thyroidectomy (p < 0.05). The incidence of postoperative hoarse in the INTP group was lower as compared to the control group in open and transoral endoscopic thyroidectomy (p < 0.05). Postoperative calcium levels (p < 0.01) were significantly higher, and the white blood cells (p < 0.05) and C-reactive protein levels (p < 0.01) were significantly decreased in the INTP group compared with the control group in transoral endoscopic thyroidectomy. Conclusions This was the first instance of the INTP strategy being introduced and was found to be an effective method for protecting the RLN in open, trans breast, and transoral endoscopic thyroidectomy. Additionally, INTP helped protect other important tissues such as the parathyroid glands in transoral endoscopic thyroidectomy as well as in reducing postoperative inflammatory responses.
Collapse
Affiliation(s)
- Xing Yu
- Department of Thyroid Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Yujun Li
- College of Medicine, Zhejiang University, Hangzhou, China
| | - Chang Liu
- College of Medicine, Zhejiang University, Hangzhou, China
| | - Yuancong Jiang
- College of Medicine, Zhejiang University, Hangzhou, China
| | - Zhaodi Liu
- College of Medicine, Zhejiang University, Hangzhou, China
| | - Qionghua He
- College of Medicine, Zhejiang University, Hangzhou, China
| | - Yong Wang
- Department of Thyroid Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Ping Wang
- Department of Thyroid Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
8
|
Wang JJ, Huang TY, Wu CW, Lin YC, Tseng HY, Liu CH, Lu IC, Chang PY, Chen HC, Chen HY, Dionigi G, Chiang FY, Wang LF. Improving Voice Outcomes After Thyroid Surgery - Review of Safety Parameters for Using Energy-Based Devices Near the Recurrent Laryngeal Nerve. Front Endocrinol (Lausanne) 2021; 12:793431. [PMID: 34899616 PMCID: PMC8662988 DOI: 10.3389/fendo.2021.793431] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 11/08/2021] [Indexed: 11/13/2022] Open
Abstract
Technological advances in thyroid surgery have rapidly increased in recent decades. Specifically, recently developed energy-based devices (EBDs) enable simultaneous dissection and sealing tissue. EBDs have many advantages in thyroid surgery, such as reduced blood loss, lower rate of post-operative hypocalcemia, and shorter operation time. However, the rate of recurrent laryngeal nerve (RLN) injury during EBD use has shown statistically inconsistent. EBDs generate high temperature that can cause iatrogenic thermal injury to the RLN by direct or indirect thermal spread. This article reviews relevant medical literatures of conventional electrocauteries and different mechanisms of current EBDs, and compares two safety parameters: safe distance and cooling time. In general, conventional electrocautery generates higher temperature and wider thermal spread range, but when applying EBDs near the RLN adequate activation distance and cooling time are still required to avoid inadvertent thermal injury. To improve voice outcomes in the quality-of-life era, surgeons should observe safety parameters and follow the standard procedures when using EBDs near the RLN in thyroid surgery.
Collapse
Affiliation(s)
- Jia Joanna Wang
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Tzu-Yen Huang
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
| | - Che-Wei Wu
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
- Center for Liquid Biopsy and Cohort Research, and Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Yi-Chu Lin
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Hsin-Yi Tseng
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Cheng-Hsin Liu
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - I-Cheng Lu
- Department of Anesthesiology, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Pi-Ying Chang
- Department of Anesthesiology, Kaohsiung Municipal Tatung Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Hui-Chun Chen
- Department of Nursing, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Hsiu-Ya Chen
- Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Gianlorenzo Dionigi
- Division of General Surgery, Endocrine Surgery Section, Istituto Auxologico Italiano IRCCS, Milan, Italy
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Feng-Yu Chiang
- Department of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan
| | - Ling-Feng Wang
- Department of Otorhinolaryngology-Head and Neck Surgery, International Thyroid Surgery Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
9
|
Tommaselli GA, Grange P, Ricketts CD, Clymer JW, Fryrear RS. Intraoperative Measures to Reduce the Risk of COVID-19 Transmission During Minimally Invasive Procedures: A Systematic Review and Critical Appraisal of Societies' Recommendations. Surg Laparosc Endosc Percutan Tech 2021; 31:765-777. [PMID: 34320592 PMCID: PMC8635252 DOI: 10.1097/sle.0000000000000972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The coronavirus 2019 pandemic and the hypothetical risk of virus transmission through aerosolized CO2 or surgical smoke produced during minimally invasive surgery (MIS) procedures have prompted societies to issue recommendations on measures to reduce this risk. The aim of this systematic review is to identify, summarize and critically appraise recommendations from surgical societies on intraoperative measures to reduce the risk of severe acute respiratory syndrome coronavirus 2 transmission to the operative room (OR) staff during MIS. METHODS Medline, Embase, and Google Scholar databases were searched using a search strategy or free terms. The search was supplemented with searches of additional relevant records on coronavirus 2019 resource websites from Surgical Associations and Societies. Recommendations published by surgical societies that reported on the intraoperative methods to reduce the risk of severe acute respiratory syndrome coronavirus 2 transmission to the OR staff during MIS were also reviewed for inclusion. Expert opinion articles were excluded. A preliminary synthesis was performed of the extracted data to categorize and itemize the different types of recommendations. The results were then summarized in a narrative synthesis. RESULTS Thirty-three recommendation were included in the study. Most recommendations were targeted to general surgery (13) and gynecology (8). Areas covered by the documents were recommendations on performance of laparoscopic/robotic surgery versus open approach (28 documents), selection of surgical staff (13), management of pneumoperitoneum (33), use of energy devices (20), and management of surgical smoke and pneumoperitoneum desufflation (33) with varying degree of consensus on the specific recommendations among the documents. CONCLUSIONS While some of the early recommendations advised against the use of MIS, they were not strictly based on the available scientific evidence. After further consideration of the literature and of the well-known benefits of laparoscopy to the patient, later recommendations shifted to encouraging the use of MIS as long as adequate precautions could be taken to protect the safety of the OR staff. The release and implementation of recommendations should be based on evidence-based practices that allows health care systems to provide safe surgical and medical assistance.
Collapse
|