1
|
Hull ML. Critical Examination of Methods to Determine Tibiofemoral Kinematics and Tibial Contact Kinematics Based on Analysis of Fluoroscopic Images. J Biomech Eng 2024; 146:110801. [PMID: 38959087 DOI: 10.1115/1.4065878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Accepted: 07/02/2024] [Indexed: 07/05/2024]
Abstract
Goals of knee replacement surgery are to restore function and maximize implant longevity. To determine how well these goals are satisfied, tibial femoral kinematics and tibial contact kinematics are of interest. Tibiofemoral kinematics, which characterize function, is movement between the tibia and femur whereas tibial contact kinematics, which is relevant to implant wear, is movement of the location of contact by the femoral implant on the tibial articular surface. The purposes of this review article are to describe and critique relevant methods to guide correct implementation. For tibiofemoral kinematics, methods are categorized as those which determine (1) relative planar motions and (2) relative three-dimensional (3D) motions. Planar motions are determined by first finding anterior-posterior (A-P) positions of each femoral condyle relative to the tibia and tracking these positions during flexion. Of the lowest point (LP) and flexion facet center (FFC) methods, which are common, the lowest point method is preferred and the reasoning is explained. 3D motions are determined using the joint coordinate system (JCS) of Grood and Suntay. Previous applications of this JCS have resulted in motions which are largely in error due to "kinematic crosstalk." Requirements for minimizing kinematic crosstalk are outlined followed by an example, which demonstrates the method for identifying a JCS that minimizes kinematic crosstalk. Although kinematic crosstalk can be minimized, the need for a JCS to determine 3D motions is questionable based on anatomical constraints, which limit varus-valgus rotation and compression-distraction translation. Methods for analyzing tibial contact kinematics are summarized and validation of methods discussed.
Collapse
Affiliation(s)
- Maury L Hull
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616; Department of Mechanical Engineering, University of California Davis, Davis, CA 95616; Department of Orthopaedic Surgery, University of California Davis, Davis, CA 95616
| |
Collapse
|
2
|
Han SH, Lee MS, Kong SH. Clinical Benefit of Robotic-Assisted Total Knee Arthroplasty over Conventional Total Knee Arthroplasty When Using Mobile-Bearing Implants. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1103. [PMID: 39064532 PMCID: PMC11279226 DOI: 10.3390/medicina60071103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 06/26/2024] [Accepted: 07/05/2024] [Indexed: 07/28/2024]
Abstract
Background and Objectives: As a treatment modality for advanced knee osteoarthritis, total knee arthroplasty is well established and has been performed on many patients over time. To improve surgical outcomes, fixed-bearing implant insertion with robotic-assisted TKA has been introduced; however, the insertion of mobile-bearing (MB) implants with the same method is challenging. The aim of this study was to compare the short-term postoperative follow-up outcomes of MB implant insertion using a robotic-assisted TKA system and conventional TKA. Materials and Methods: We investigated functional improvement in the knees of 60 patients who underwent the insertion of MB implants using either robotic-assisted TKA or conventional TKA. Isokinetic muscular function, range of motion, the Western Ontario and McMaster Universities Osteoarthritis Index score, visual analog scale (VAS) score, and Knee Society Score (KSS) were measured 6 months after surgery. The statistical analysis of outcome measurements was performed using the Mann-Whitney U test and the Wilcoxon signed-rank test. Results: Some isokinetic muscular functions, as well as Knee Society Scores (pain and function) and VAS scores, were significantly higher in patients who underwent MB insertion with robotic-assisted TKA than in those who underwent conventional TKA. Conclusions: When an MB implant is inserted using a robotic-assisted TKA system, a better surgical outcome can be expected.
Collapse
Affiliation(s)
- Sang-Ho Han
- Department of Orthopedic Surgery, Daechan Hospital, 590 Inju-daero, Namdong-gu, Incheon 21570, Republic of Korea; (S.-H.H.); (M.-S.L.)
| | - Min-Soo Lee
- Department of Orthopedic Surgery, Daechan Hospital, 590 Inju-daero, Namdong-gu, Incheon 21570, Republic of Korea; (S.-H.H.); (M.-S.L.)
| | - Se-Hee Kong
- Daechan Sports Medical Research Center, 590 Inju-daero, Namdong-gu, Incheon 21570, Republic of Korea
| |
Collapse
|
3
|
Yao K, Chen Y. Comprehensive evaluation of risk factors for aseptic loosening in cemented total knee arthroplasty: A systematic review and meta-analysis. J Exp Orthop 2024; 11:e12095. [PMID: 39035847 PMCID: PMC11260281 DOI: 10.1002/jeo2.12095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 06/03/2024] [Indexed: 07/23/2024] Open
Abstract
Purpose Aseptic loosening is the most common cause for revisions after total knee arthroplasty (TKA). Despite many studies exploring various risk factors associated with aseptic loosening, findings often present inconsistencies. To address this, we conducted a thorough review of the literature to identify and analyse these risk factors in cemented TKA. Additionally, we performed a meta-analysis to reconcile the divergent conclusions observed across studies. Methods We searched PubMed, Web of Science and Embase from 1996 up to 2024 and evaluated the quality of the included literature. Seventy-four studies were included to assess the association of BMI, diabetes, high physical activity (HPA), osteoporosis, rheumatoid arthritis (RA), cement material and implant design. Twenty-nine studies were used to calculate relative risk and CIs (using the random effects theory) and study heterogeneity for six different risk factors (BMI, diabetes, HPA level, cement material, polyethylene and implant design). Results Patients with diabetes are eight times more likely to experience aseptic loosening compared to those without diabetes (RR = 9.18, 95% CI: 1.80-46.77, p < 0.01). The use of tibial stem extension or highly crosslinked polyethylene can help reduce the incidence of aseptic loosening. However, we did not identify BMI, HPA, osteoporosis, RA, the use of high-viscosity cement and the utilization of mobile-bearing designs as risk factors for aseptic loosening post-cemented TKA. Conclusions Patients with diabetes undergoing TKA should be counselled regarding their potential increased risk of aseptic loosening. The use of tibial stem extensions and HXLPE can mitigate the incidence of aseptic loosening in cemented TKA. However, given a limited number of studies were included in the meta-analysis, we believe that higher-level studies are necessary to clearly identify other risk factors. Level of Evidence Level III.
Collapse
Affiliation(s)
- Kaiyi Yao
- Faculty of Medicine and Health SciencesGhent UniversityGhentBelgium
| | - Yao Chen
- Department of Applied Mathematics, Computer Science and StatisticsGhent UniversityGhentBelgium
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and NutritionGhent UniversityMerelbekeBelgium
- DIGPCR‐Ghent University Digital PCR ConsortiumGhent UniversityMerelbekeBelgium
| |
Collapse
|
4
|
Wagner A, Wittig U, Leitner L, Vielgut I, Hauer G, Ortmaier R, Leithner A, Sadoghi P. Comparison of revision rates and epidemiological data of a single total knee arthroplasty system of different designs (cruciate retaining, posterior stabilized, mobile bearing, and fixed bearing): a meta-analysis and systematic review of clinical trials and national arthroplasty registries. Arch Orthop Trauma Surg 2024; 144:1997-2006. [PMID: 38570357 PMCID: PMC11093798 DOI: 10.1007/s00402-024-05286-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 03/10/2024] [Indexed: 04/05/2024]
Abstract
BACKGROUND This study aimed to meta-analyze epidemiological data, revision rates, and incidences of different designs of a single Total Knee Arthroplasty System and compare these factors across different countries. METHODS A systematic review was conducted on clinical studies and arthroplasty registries of ATTUNE TKA from 1999 to 2020. The main endpoints analyzed were revision rates and epidemiological data. RESULTS The average age of patients was 67.8 years, with a gender distribution of 60% female and 40% male. The pooled average BMI was 29.4 kg/m2. Eight clinical studies showed a pooled revision rate per 100 observed CY of 0.5 (n = 1343 cases). Cumulative revision rates after 1, 3, and 5 years varied among registries, with the Swiss registry having the highest revision data (after 5 years: 6.3%) and the American registry having the lowest revision data (after 5 years: 1.7%). A comparison of the revision rates of mobile bearing and fixed bearing (41,200 cases) as well as cruciate retaining and posterior stabilized (n = 123,361 cases) showed no significant advantage in the first 5 years after implantation. CONCLUSION In conclusion, pooled data from 41,200 cases of TKA with a single Total Knee Arthroplasty System in two arthroplasty registries revealed that there was no significant difference in revision rates between the mobile bearing and fixed bearing design within the first 5 years after implantation. In addition, a comparison of the revision rates in n = 123,361 cases showed no significant advantage for cruciate retaining or posterior stabilized in the first 5 years after implantation.
Collapse
Affiliation(s)
- Anton Wagner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Ulrike Wittig
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Lukas Leitner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Ines Vielgut
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Georg Hauer
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Reinhold Ortmaier
- Ordensklinikum Linz, Barmherzige Schwestern, Seilerstätte 4, 4010, Linz, Austria
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Patrick Sadoghi
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
| |
Collapse
|
5
|
Abdioğlu AA, Peker G. Comparison of bilateral cementless total knee arthroplasty results between patients in different BMI groups. Arch Orthop Trauma Surg 2024; 144:2317-2326. [PMID: 38642162 DOI: 10.1007/s00402-024-05335-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 04/14/2024] [Indexed: 04/22/2024]
Abstract
INTRODUCTION The aim of this study was to compare the results of cementless bilateral total knee arthroplasty (TKA) between individuals in different obesity groups. MATERIALS AND METHODS This was a retrospective cohort study. Patients with a body mass index (BMI) greater than 25 who underwent bilateral TKA for gonarthrosis between 2014 and 2020 and completed a minimum follow-up of 24 months were included. Age, sex, height, weight, BMI, operation time, length of stay, patient satisfaction, knee scores and complications were compared. Patients with missing data, who were followed for less than 24 months or had postoperative fractures around the knee were excluded. RESULTS There was a significant difference between the groups in terms of operation time (Class III > overweight > Class II > Class I p < 0.001). There was a significant difference in complications between the groups (Class III > Class I > Class II > overweight p = 0.010). According to our pairwise comparison, complications were more common in the class III group than in the overweight group. Knee score (KS) and function score (FS) increased significantly after surgery in all groups (p < 0.001), with no difference in FS (p = 0.448). Knee score changes were greater in the overweight and class I groups (p < 0.001). There was a significant interaction between both KS and FS and person satisfaction (p < 0.001). CONCLUSION Cementless TKA improved KS and FS in all obesity groups, yielded high patient satisfaction. Although the incidence of complications was higher in the morbidly obese patients than in the overweight patients, the difference was not significant. Patients with morbid obesity should be informed about related risks before planning cementless TKA.
Collapse
Affiliation(s)
- Ahmet Atilla Abdioğlu
- Department of Orthopedics and Traumatology, Fatih State Hospital, Trabzon, 61100, Turkey.
| | - Gökhan Peker
- Department Of Orthopedics and Traumatology, University of Health Sciences, Trabzon Kanuni Training and Research Hospital, Trabzon, Turkey
| |
Collapse
|
6
|
Pan H, Yang M, Ji WH, Cui RZ, Liu GQ. A Retrospective Study to Compare Patient Outcomes from Standard Total Knee Arthroplasty (TKA) versus Navigation-Guided Arthroplasty Using the Brainlab Software-Guided Surgical System at a Center in Hebei Province January 2021 to July 2023. Med Sci Monit 2024; 30:e942888. [PMID: 38576138 PMCID: PMC11003309 DOI: 10.12659/msm.942888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 02/14/2024] [Indexed: 04/06/2024] Open
Abstract
BACKGROUND This retrospective study aimed to compare patient outcomes from standard total knee arthroplasty (TKA) vs navigation-guided arthroplasty using the Brainlab software-guided surgical system at Cangzhou Hospital of Integrated TCM-WM, Hebei, Hebei Province, China from January 2021 to July 2023. MATERIAL AND METHODS A total of 239 patients who underwent total knee arthroplasty in Cangzhou Hospital of Integrated TCM-WM, Hebei from January 2021 to July 2023 were retrospectively analyzed. According to the inclusion criteria, 212 eligible patients were selected for analysis and divided into a Navigation Group (NG) (n=105) and a Traditional Group (TG) (n=107) according to surgical method used. Outcomes measured included duration of disease, operative time, intraoperative blood loss volume, postoperative length of hospital stay, and pain measured by the hospital for special surgery knee score (HSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and forgotten joint score (FJS). RESULTS The comparison of perioperative results between the 2 groups showed that the incision length in the NG was significantly longer than that in the TG (P<0.001, 95% Cl 2.59-3.35). At 3 months after surgery, the HSS score of the NG was statistically higher than that of the TG (P=0.002, 95% Cl 3.42-4.46); the WOMAC score of the NG was lower than that of the TG (P<0.001, 95% Cl -4.41-2.87); and the FJS score of the NG was significantly higher than that of the TG (P=0.003, 95% Cl 2.39-3.67). CONCLUSIONS Compared with conventional TKA, use of the Brainlab navigation system is associated with a longer incision, more accurate implantation position of the prosthesis, faster recovery of knee joint function, and helps patients to "forget" about their knee prosthesis in the short term.
Collapse
|
7
|
Alrajeb R, Zarti M, Shuia Z, Alzobi O, Ahmed G, Elmhiregh A. Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1333-1343. [PMID: 38133653 PMCID: PMC10980635 DOI: 10.1007/s00590-023-03798-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Accepted: 11/25/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVES Robotic knee arthroplasty procedures have emerged as a new trend, garnering attention from orthopedic surgeons globally. It has been hypothesized that the use of robotics enhances the accuracy of prosthesis positioning and alignment restoration. The objective of this study was to provide a high-level, evidence-based comparison between robotic total knee replacements and conventional methods, focusing on radiological and functional outcomes. METHODS We searched five databases from their inception until June 1, 2022, specifically targeting randomized controlled trials (RCTs) that compared the outcomes of robotic and conventional total knee replacements. We were interested in outcomes such as knee range of motion, clinical and function knee society scores, the Western Ontario and McMaster University score (WOMAC), the Hospital of Special Surgery score, complications, and radiological alignment. This review was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyzes guidelines. We assessed the risk of bias using the revised Cochrane risk-of-bias tool for randomized trials (RoB 2). RESULTS Our search returned seven RCTs suitable for our analysis, which included a total of 1942 knees; 974 of these knees were implanted using robotic arms while the remaining 968 utilized jig-based knee systems. Our findings indicated that robotic knees had significantly better post-operative anatomical (OR - 0.82; 95% CI, - 1.027 to - 0.58, p value < 0.00001) and mechanical restoration (OR - 0.95; 95% CI, - 1.49 to - 0.41, p value < 0.0006). While knee range of motion (OR - 2.23; 95% CI - 4.89-0.43, p value 0.1) and femoral prosthesis position (OR - 0.98; 95% CI, - 2.03-0.08, p value 0.07) also favored robotic knees, these differences did not reach statistical significance. Both clinical and functional outcomes, as well as the rate of complications, were found to be statistically similar between the groups undergoing robotic and traditional knee replacement surgeries. CONCLUSION This meta-analysis indicates that robotic total knee replacements offer superior post-operative anatomical and mechanical alignment compared to conventional total knee replacements. Despite this, clinical and functional outcomes, as well as complication rates, were similar between the two. These findings should be considered in light of potential confounding factors. More randomized controlled trials with the latest robotic systems are needed to confirm any superior functional and clinical outcomes from robotic-assisted surgeries. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
| | | | | | - Osama Alzobi
- Department of Orthopedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar.
| | - Ghalib Ahmed
- Department of Orthopedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | | |
Collapse
|
8
|
Elmhiregh A, Abuodeh Y, Alzobi O, Zikria B, Alkhayarin M, Morrey BF. All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023; 33:3611-3622. [PMID: 37249643 PMCID: PMC10651551 DOI: 10.1007/s00590-023-03594-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 05/14/2023] [Indexed: 05/31/2023]
Abstract
OBJECTIVES The design of tibial trays for total knee arthroplasty (TKA) has been a topic of research for several decades. Although all-polyethylene trays were developed to address issues such as osteolysis and to enhance the longevity of the prosthesis, as well as knee range of motion, metal-backed designs have remained the most commonly used type of prosthesis. This meta-analysis aimed to compare the clinical, radiological, and survival outcomes of both designs. METHODS Five databases were searched from inception until October 1, 2020, for randomized controlled trials (RCTs) that compared the outcomes of all-polyethylene and metal-backed tibial components in TKA. The outcomes of interest included range of motion, knee society score, stairs climbing scores, radiostereographic analysis, survivorship and complication. This review was conducted in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Risk of bias was assessed using the Newcastle-Ottawa tool. RESULTS A total of 14 RCTs with 1367 TKA were included with a mean age of - years and - years for all-polyethylene and metal-backed tibial components groups, respectively. All-polyethylene group demonstrated statistically significant differences in five-year survivorship (OR 0.27; 95% CI 0.10-0.75; p value 0.01) and stairs climbing score (OR - 2.07; 95% CI - 3.27-0.87; p value 0.0007) when compared to the metal-backed group. The metal-backed design was significantly more radiographically stable in anterior-posterior, varus-valgus, and internal-external rotations at the 2-year follow-up compared to all-polyethylene tibias (OR - 0.09; 95% CI - 0.16 to - 0.02; p value 0.02) as per the pooled radiostereographic analysis. However, ten-year survivorship (OR 0.92; 95% CI 0.53-1.60; p value 0.78), range of motion (OR - 0.57; 95% CI - 2.00-0.85, p value 0.43), knee society scores (OR 1.38; 95% CI - 0.47-3.23, p value 0.14), and complications (OR 0.83; 95% CI 0.5-1.39, p value 0.48) were comparable between both groups. CONCLUSIONS While this meta-analysis suggests that all-polyethylene tibial components in total knee arthroplasty may offer advantages over metal-backed components in terms of five-year survivorship, and stairs climbing score, this finding should be considered in the context of potential confounding factors. Nonetheless, based on the results, the all-polyethylene implant should be considered a viable choice for primary knee replacement. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
| | - Yousef Abuodeh
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Osama Alzobi
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar.
| | - Bashir Zikria
- Aspetar Orthopaedic and Sports Medicine Hospital, Doha, Qatar
| | - Mohd Alkhayarin
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | | |
Collapse
|
9
|
Zinno R, Alesi D, Di Paolo S, Pizza N, Zaffagnini S, Marcheggiani Muccioli GM, Bragonzoni L. Wider translations and rotations in posterior-stabilised mobile-bearing total knee arthroplasty compared to fixed-bearing both implanted with mechanical alignment: a dynamic RSA study. Knee Surg Sports Traumatol Arthrosc 2023; 31:4969-4976. [PMID: 37615718 PMCID: PMC10598183 DOI: 10.1007/s00167-023-07541-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 08/04/2023] [Indexed: 08/25/2023]
Abstract
PURPOSE The purpose of this study was to investigate the in vivo kinematics of the same femoral design mechanically aligned posterior-stabilised (PS) total knee arthroplasty (TKA) with either fixed-bearing (FB) or mobile-bearing (MB) inlay, implanted by the same surgeon, using model-based dynamic radiostereometric analysis (RSA). The hypothesis of the present study was that the MB design would show wider axial rotation than the FB design, without affecting the clinical outcomes. MATERIALS AND METHODS A cohort of 21 non-randomised patients (21 DePuy Attune PS-FB) was evaluated by dynamic RSA analysis at a minimum 9-month follow-up, while performing differently demanding daily living activities such as sit to stand (STS) and deep knee lunge (DKL). Kinematic data were compared with those of a cohort of 22 patients implanted with the same prosthetic design but with MB inlay. Anterior-posterior (AP) translations, varus-valgus (VV) and internal-external (IE) rotations of the femoral component with respect to the tibial baseplate were investigated. Translation of medial and lateral compartment was analysed using the low point method according to Freeman et al. Questionnaires to calculate objective and subjective clinical scores were administered preoperatively and during follow-up visit by the same investigator. RESULTS The FB TKA design showed lower AP translation during STS (6.8 ± 3.3 mm in FB vs 9.9 ± 3.7 mm in MB, p = 0.006*), lower VV rotation (1.9 ± 0.8° in FB vs 5.3 ± 3.3° in MB, p = 0.005) and lower IE rotation (2.8 ± 1.1° in FB vs 9.5 ± 4.3° in MB, p = 0.001) during DKL than the mobile-bearing TKA design. Posterior-stabilised FB group showed significant lower translation of the low point of the medial compartment than the MB group (p = 0.008). The percentage of patients performing medial pivot in the FB group was higher compared to MB group in the examined motor tasks. No significant differences in post-operative range of motion (117° ± 16° for FB group and 124° ± 13° for MB group) and in clinical outcomes emerged between the two cohort. CONCLUSIONS The FB and MB designs differed in AP translations, VV rotations and IE rotations of the femoral component with respect to the tibial component in STS and DKL. Furthermore, FB cohort reported a significant higher percentage of medial pivot with respect to MB cohort. Despite this, no differences in clinical outcomes were detected between groups. Both designs showed stable kinematics and represent a viable option in primary TKA. LEVEL OF EVIDENCE Prospective cohort study, II.
Collapse
Affiliation(s)
- Raffaele Zinno
- Dipartimento Di Scienze Per La Qualità Della Vita QUVI, University of Bologna, Corso D’Augusto 237, 47921 Rimini, RN Italy
| | - Domenico Alesi
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136 Bologna, BO Italy
- Dipartimento di Scienze Biomediche e Neuromotorie DIBINEM, University of Bologna, Via San Vitale, 40125 Bologna, BO Italy
| | - Stefano Di Paolo
- Dipartimento Di Scienze Per La Qualità Della Vita QUVI, University of Bologna, Corso D’Augusto 237, 47921 Rimini, RN Italy
| | - Nicola Pizza
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136 Bologna, BO Italy
| | - Stefano Zaffagnini
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136 Bologna, BO Italy
- Dipartimento di Scienze Biomediche e Neuromotorie DIBINEM, University of Bologna, Via San Vitale, 40125 Bologna, BO Italy
| | - Giulio Maria Marcheggiani Muccioli
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136 Bologna, BO Italy
- Dipartimento di Scienze Biomediche e Neuromotorie DIBINEM, University of Bologna, Via San Vitale, 40125 Bologna, BO Italy
| | - Laura Bragonzoni
- Dipartimento Di Scienze Per La Qualità Della Vita QUVI, University of Bologna, Corso D’Augusto 237, 47921 Rimini, RN Italy
| |
Collapse
|
10
|
Tsai YL, Tsai SHL, Lin CH, Lin CR, Hu CC. The Effect of Congruent Tibial Inserts in Total Knee Arthroplasty: A Network Meta-Analysis of Randomized Controlled Trials. Life (Basel) 2023; 13:1942. [PMID: 37763345 PMCID: PMC10532924 DOI: 10.3390/life13091942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 09/07/2023] [Accepted: 09/18/2023] [Indexed: 09/29/2023] Open
Abstract
Objective: The aim of this study was to determine whether modern congruent tibial inserts are associated with superior outcomes in total knee arthroplasty (TKA). Background: Ultracongruent fixed-bearing (UCFB) and medial congruent fixed-bearing (MCFB) inserts have been known to be effective in total knee arthroplasty with patient satisfaction. Nonetheless, no supporting evidence to date exists to rank the clinical outcomes of these various congruent inserts in TKA compared with other important considerations in TKA including cruciate-retaining fixed-bearing (CRFB) and posterior-stabilized fixed-bearing (PSFB) inserts. Methods: We searched PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Scopus up to 15 May 2022. We selected studies involving an active comparison of UCFB or MCFB in TKAs. We performed a network meta-analysis (NMA) of randomized controlled trials (RCTs) and compared different congruent inserts. We ranked the clinical outcomes by SUCRA score with the estimate of the best treatment probability. Our primary outcomes were revision rates and radiolucent lines. Secondary outcomes were functional scores, including the range of motion (ROM), the Knee Society Score (KSS), the Oxford Knee Score (OKS), and WOMAC. Results: Eighteen RCTs with 1793 participants were analyzed. Our NMA ranked MCFB, CRFB, and UCFB with the lowest revision rates. CRFB and UCFB had the fewest radiolucent lines. UCFB had overall the best ROM. UCFB and MCFB had the best OKS score overall. Conclusions: The ranking probability for better clinical outcomes in congruent inserts demonstrated the superiority of congruent tibial inserts, including UCFB and MCFB. UCFB may be associated with better ROM and postoperative functional outcomes. However, integrating future RCTs for high-level evidence is necessary to confirm these findings.
Collapse
Affiliation(s)
- Yen-Lin Tsai
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
| | - Sung Huang Laurent Tsai
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Keelung Branch, Keelung 204, Taiwan
| | - Chia-Han Lin
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan
| | - Chun-Ru Lin
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
| | - Chih-Chien Hu
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
| |
Collapse
|
11
|
Sharifi-Renani M, Mahoor MH, Clary CW. BioMAT: An Open-Source Biomechanics Multi-Activity Transformer for Joint Kinematic Predictions Using Wearable Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:5778. [PMID: 37447628 DOI: 10.3390/s23135778] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 06/08/2023] [Accepted: 06/15/2023] [Indexed: 07/15/2023]
Abstract
Through wearable sensors and deep learning techniques, biomechanical analysis can reach beyond the lab for clinical and sporting applications. Transformers, a class of recent deep learning models, have become widely used in state-of-the-art artificial intelligence research due to their superior performance in various natural language processing and computer vision tasks. The performance of transformer models has not yet been investigated in biomechanics applications. In this study, we introduce a Biomechanical Multi-activity Transformer-based model, BioMAT, for the estimation of joint kinematics from streaming signals of multiple inertia measurement units (IMUs) using a publicly available dataset. This dataset includes IMU signals and the corresponding sagittal plane kinematics of the hip, knee, and ankle joints during multiple activities of daily living. We evaluated the model's performance and generalizability and compared it against a convolutional neural network long short-term model, a bidirectional long short-term model, and multi-linear regression across different ambulation tasks including level ground walking (LW), ramp ascent (RA), ramp descent (RD), stair ascent (SA), and stair descent (SD). To investigate the effect of different activity datasets on prediction accuracy, we compared the performance of a universal model trained on all activities against task-specific models trained on individual tasks. When the models were tested on three unseen subjects' data, BioMAT outperformed the benchmark models with an average root mean square error (RMSE) of 5.5 ± 0.5°, and normalized RMSE of 6.8 ± 0.3° across all three joints and all activities. A unified BioMAT model demonstrated superior performance compared to individual task-specific models across four of five activities. The RMSE values from the universal model for LW, RA, RD, SA, and SD activities were 5.0 ± 1.5°, 6.2 ± 1.1°, 5.8 ± 1.1°, 5.3 ± 1.6°, and 5.2 ± 0.7° while these values for task-specific models were, 5.3 ± 2.1°, 6.7 ± 2.0°, 6.9 ± 2.2°, 4.9 ± 1.4°, and 5.6 ± 1.3°, respectively. Overall, BioMAT accurately estimated joint kinematics relative to previous machine learning algorithms across different activities directly from the sequence of IMUs signals instead of time-normalized gait cycle data.
Collapse
Affiliation(s)
| | - Mohammad H Mahoor
- Computer Vision and Social Robotics Laboratory, University of Denver, Denver, CO 80208, USA
| | - Chadd W Clary
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO 80208, USA
| |
Collapse
|
12
|
Zhang ZH, Qi YS, Wei BG, Bao HRC, Xu YS. Application strategy of finite element analysis in artificial knee arthroplasty. Front Bioeng Biotechnol 2023; 11:1127289. [PMID: 37265991 PMCID: PMC10230366 DOI: 10.3389/fbioe.2023.1127289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/27/2023] [Indexed: 06/03/2023] Open
Abstract
Artificial knee arthroplasty, as the most effective method for the treatment of end-stage joint diseases such as knee osteoarthritis and rheumatoid arthritis, is widely used in the field of joint surgery. At present, Finite element analysis (FEA) has been widely used in artificial knee replacement biomechanical research. This review presents the current hotspots for the application of FEA in the field of artificial knee replacement by reviewing the existing research literature and, by comparison, summarizes guidance and recommendations for artificial knee replacement surgery. We believe that lower contact stress can produce less wear and complications when components move against each other, in the process of total knee arthroplasty (TKA), mobile-bearing prostheses reduce the contact surface stress of the tibial-femoral joint compared with fixed-bearing prostheses, thus reducing the wear of the polyethylene insert. Compared with mechanical alignment, kinematic alignment reduces the maximum stress and maximum strain of the femoral component and polyethylene insert in TKA, and the lower stress reduces the wear of the joint contact surface and prolongs the life of the prosthesis. In the unicompartmental knee arthroplasty (UKA), the femoral and tibial components of mobile-bearing prostheses have better conformity, which can reduce the wear of the components, while local stress concentration caused by excessive overconformity of fixed-bearing prostheses should be avoided in UKA to prevent accelerated wear of the components, the mobile-bearing prosthesis maintained in the coronal position from 4° varus to 4° valgus and the fixed-bearing prosthesis implanted in the neutral position (0°) are recommended. In revision total knee arthroplasty (RTKA), the stem implant design should maintain the best balance between preserving bone and reducing stress around the prosthesis after implantation. Compared with cemented stems, cementless press-fit femoral stems show higher fretting, for tibial plateau bone defects, porous metal blocks are more effective in stress dispersion. Finally, compared with traditional mechanical research methods, FEA methods can yield relatively accurate simulations, which could compensate for the deficiencies of traditional mechanics in knee joint research. Thus, FEA has great potential for applications in the field of medicine.
Collapse
Affiliation(s)
- Zi-Heng Zhang
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
- Graduate School, Inner Mongolia Medical University, Hohhot, China
| | - Yan-Song Qi
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Bao-Gang Wei
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Hu-Ri-Cha Bao
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Yong-Sheng Xu
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| |
Collapse
|
13
|
Foster NE, L E, L D, M H. Osteoarthritis year in review 2022: epidemiology & therapy. Osteoarthritis Cartilage 2023:S1063-4584(23)00730-6. [PMID: 36963607 DOI: 10.1016/j.joca.2023.03.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/09/2023] [Accepted: 03/15/2023] [Indexed: 03/26/2023]
Abstract
This 'Year in Review' provides a synopsis of key research themes and individual studies from the clinical osteoarthritis (OA) field, focused on epidemiology and therapy. The electronic database search for the review was adapted from the 2021 year in review search, to increase search specificity for relevant study designs, and was conducted in Medline, Embase and medRxiv (31st March 2021 to 4th March 2022). Following screening for eligibility, studies were grouped according to their key research design, including reviews, cohorts and randomised trials. 11 key themes emerged, including the importance of several comorbidities in predicting OA incidence and prevalence, surgical approaches that can reduce the risk of post-traumatic OA, the heterogenous but nevertheless relatively stable nature of OA subgroup trajectories, the paucity of robust studies particularly of surgery for OA and the very modest benefit of many therapies under evaluation in trials. A particular interest of the authors was to consider whether new studies are helping determine how to better ensure the right patient with OA is matched to the right treatment at the right time. There are several new studies developing improved predictive models through big data analytics and machine learning which show promise, need validation, and may support new approaches to stratified care.
Collapse
Affiliation(s)
- Nadine E Foster
- STARS Education and Research Alliance, Surgical Treatment and Rehabilitation Service (STARS), The University of Queensland and Metro North Health, Queensland, Australia.
| | - Eriksson L
- Lars Eriksson, The University of Queensland, UQ Library, Herston Qld 4006, Queensland, Australia.
| | - Deveza L
- Institute of Bone and Joint Research, Kolling Institute of Medical Research, The University of Sydney, Sydney, New South Wales, Australia; Department of Rheumatology, Northern Clinical School, Royal North Shore Hospital, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
| | - Hall M
- Centre for Health, Exercise and Sports Medicine, University of Melbourne, Victoria, Australia.
| |
Collapse
|
14
|
Hegde V, Kendall J, Schabel K, Pelt CE, Yep P, Mullen K, De A, Kagan R. The James A. Rand Young Investigator's Award: Increased Revision Risk With Mobile Bearings in Total Knee Arthroplasty: An Analysis of the American Joint Replacement Registry. J Arthroplasty 2023:S0883-5403(23)00007-4. [PMID: 36639116 DOI: 10.1016/j.arth.2023.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 12/25/2022] [Accepted: 01/04/2023] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND Mobile-bearing (MB) total knee arthroplasty (TKA) may reduce wear and improve patellar tracking but may increase revision risk due to tibial component design, balance complexity, and bearing dislocation. We utilized the American Joint Replacement Registry to examine risk of revision with MB compared to fixed-bearing (FB) designs. METHODS An analysis of primary TKA in patients over 65 years was performed with American Joint Replacement Registry data linked to Centers for Medicare and Medicaid Services data from 2012 to 2019. Analyses compared MB to FB designs with a subanalysis of implants from a single company. We identified 485,024 TKAs, with 452,199 (93.2%) FB-TKAs and 32,825 (6.8%) MB-TKAs. Cox proportional hazards regression modeling was used for all-cause revision and revision for infection, adjusting for sex, age, and competing risk of mortality. Event-free survival curves evaluated time to all-cause revision and revision for infection. RESULTS MB-TKAs were at an increased risk for all-cause revision: hazard ratio (HR) 1.36 ([95% confidence interval (CI) 1.24-1.49], P < .0001) but not revision for infection: HR 1.06 ([95% CI 0.90-1.25], P = .52). When comparing implants within a single company, MB-TKAs were at an increased risk of all-cause revision: HR 1.55 ([95% CI 1.38-1.73], P < .0001). Event-free survival curves demonstrated increased risk for all-cause revision for MB-TKA across all time points, with a greater magnitude of risk up to 8 years. CONCLUSION Although survivorship of both designs was outstanding, MB-TKA designs demonstrated increased risk for all-cause revision. Additional investigation is needed to determine if this is related to patient selection factors, surgical technique, bearing, or implant design.
Collapse
Affiliation(s)
- Vishal Hegde
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | - Jamil Kendall
- Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon
| | - Kathryn Schabel
- Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon
| | - Christopher E Pelt
- Department of Orthopaedics, University of Utah School of Medicine, Salt Lake City, Utah
| | - Patrick Yep
- American Academy of Orthopaedic Surgeons, Registries and Data Science Department, Rosemont, Illinois
| | - Kyle Mullen
- American Academy of Orthopaedic Surgeons, Registries and Data Science Department, Rosemont, Illinois
| | - Ayushmita De
- American Academy of Orthopaedic Surgeons, Registries and Data Science Department, Rosemont, Illinois
| | - Ryland Kagan
- Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon
| |
Collapse
|
15
|
No component loosening of a cementless deep dish rotating platform knee at a 5-year follow-up. Knee Surg Sports Traumatol Arthrosc 2023; 31:969-978. [PMID: 35969255 PMCID: PMC9376574 DOI: 10.1007/s00167-022-07113-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 08/03/2022] [Indexed: 11/21/2022]
Abstract
PURPOSE Cemented fixation remains the gold standard in total knee arthroplasty. With an increasing number of younger patients undergoing total knee arthroplasty and a growing patient population demanding higher physical activity, a rising interest in discussion of cementless fixation is notable. The current scientific literature does not give a clear recommendation for or against uncemented total knee arthroplasty. The purpose of this study was the investigation of the 5-year clinical and radiographic outcomes of a cementless deep-dish rotating platform implant. METHODS A total of 91 primary cementless total knee arthroplasties were included in this single-centre prospective observational study. The primary outcome was revision rate due to aseptic component loosening. Further outcome measures were assessment of the of the radiographic outcome as well as the clinical outcome based on Range of Motion and scores such as American Knee Society Score, Oxford Knee Score, Knee Injury and Osteoarthritis Outcome Score and European Quality of Life 5 Dimension 3 Level at a follow-up of 5 years. RESULTS Mean age of the study population was 67.3 ± 6.6 years with 49.5% of the participants being female. Aseptic component loosening occurred in none of the patients. Implant survival with revision for any reason as endpoint was 97.8% (95% CI 100-96%) and 95.6% (95% CI 100-94%) with reoperation of any cause as endpoint. Radiolucent lines were detected in a total of eight cases (8.8%) and disappeared within the first year after surgery in five cases. Total Range of Motion improved significantly from 106° ± 15° preoperatively to 118° ± 10° at final FU (p < 0.001). All investigated scores improved significantly after total knee arthroplasty. CONCLUSION The results of this study reveal excellent mid-term performance of a cementless deep dish rotating platform total knee implant, with no component loosening, very low overall revision rate, only temporarily present radiolucent lines in a minority of patients and excellent clinical results. Therefore, cementless total knee arthroplasty is an appropriate treatment option for patients with severe osteoarthritis of the knee. LEVEL OF EVIDENCE Level II (prospective cohort study).
Collapse
|
16
|
Castellarin G, Bori E, Menon A, Innocenti B. The effect of different insert design congruencies on the kinematics of a mobile bearing TKA: A cadaveric study. J Orthop 2022; 34:89-93. [PMID: 36046758 PMCID: PMC9421089 DOI: 10.1016/j.jor.2022.07.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 06/07/2022] [Accepted: 07/25/2022] [Indexed: 11/25/2022] Open
Abstract
Introduction Total knee arthroplasty has proved to be a safe, effective and reproducible surgical treatment for patients with serious/advanced degenerative joint disease of the knee, but the optimal results after these implants can be achieved only if the joint kinematics and kinetics are carefully respected and not significantly altered after the replacement. In order to enhance the capability of matching the healthy configuration, therefore, different prosthesis models in terms of constraints and designs are available for the surgeons to choose among. As an example of this variety, mobile bearing models allow the surgeon to choose among different insert designs in terms of geometry and relative biomechanical approaches, with the relative performances depending on which one is adopted.This article aims to analyse the effect of different levels of congruency of mobile bearing inserts through an experimental activity performed on an ultra-congruent insert design, also referred as deep-dished. Methods The experimental activity followed the same protocol used in a previous study focused on the effect of symmetricity/asymmetricity (in order to allow a comparison among the results obtained), i.e. it analysed passive squat on 5 cadaveric knee specimens; internal-external rotations of femur and tibial insert respect to the tibia tray were thus measured via a motion capture system in order to compare the insert-femur relative rotation among the different congruency configurations. Results The overall knee kinematic (in terms of flexion-extension and internal-external rotation ranges of motion) with an ultra-congruent insert did not differ from the ones found for the other inserts; the insert-femur rotation values, instead, returned to be between the ones obtained with the other two inserts. Conclusion In terms of adaptability to tibio-femoral rotation, therefore, this insert represents a valid option for the surgeon seeking for an intermediate solution among the opposed approaches of the other two.
Collapse
Affiliation(s)
| | - Edoardo Bori
- Université Libre de Bruxelles, École Polytechnique de Bruxelles, BEAMS Department (Bio Electro and Mechanical Systems), Brussels, Belgium
| | | | - Bernardo Innocenti
- Université Libre de Bruxelles, École Polytechnique de Bruxelles, BEAMS Department (Bio Electro and Mechanical Systems), Brussels, Belgium
| |
Collapse
|
17
|
Shatrov J, Sappey-Marinier E, Kafelov M, Gunst S, Batailler C, Servien E, Lustig S. Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study. J Exp Orthop 2022; 9:17. [PMID: 35169966 PMCID: PMC8847635 DOI: 10.1186/s40634-022-00456-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Accepted: 02/11/2022] [Indexed: 11/12/2022] Open
Abstract
Purpose Prosthesis design influences stability in total knee arthroplasty and may affect maximum knee flexion. Posterior-stabilised (PS) and condylar-stabilised (CS) designed prosthesis do not require a posterior-cruciate ligament to provide stability. The aim of the current study was to compare the range of motion (ROM) and clinical outcomes of patients undergoing cemented total knee arthroplasty (TKA) using either a PS or CS design prosthesis. Methods A total of 167 consecutive primary TKAs with a CS bearing (mobile deep-dish polyethylene) were retrospectively identified and compared to 332 primary TKA with a PS constraint, with similar design components from the same manufacturer. Passive ROM was assessed at last follow-up with use of a handheld goniometer. Clinical scores were assessed using Patient-Reported Outcome Measures (PROMs); International Knee Society (IKS) knee and function scores and satisfaction score. Radiographic assessment was performed pre and post operatively consisting of mechanical femorotibial angle (mFTA), femoral and tibial mechanical angles measured medially (FMA and TMA, respectively) on long leg radiographs, tibial slope and patella height as measured by the Blackburne-Peel index (BPI). Results Both groups had a mean follow-up of 3 years (range 2–3.7 years). Mean post-operative maximum knee flexion was 117° ± 4.9° in the PS group and 119° ± 5.2° in the CS group (p = 0.29). Postoperative IKS scores were significantly improved in both groups compared to preoperative scores (p < 0.01). The mean IKS score in the PS group was 170.9 ± 24.1 compared to 170.3 ± 22.5 in the CS group (p = 0.3). Both groups had similar radiographic outcomes as determined by coronal and sagittal alignment, tibial slope and posterior condylar offset ratio measurements. When considering the size of tibial slope change and posterior-condylar offset ratio, there was no differences between groups (p = 0.4 and 0.59 respectively). The PS group had more interventions for post-operative stiffness (arthrolysis or manipulation under anaesthesia) 8 (2.7%) compared to 1 (0.6%) in the CS group (p = 0.17). Conclusion Condylar-stabilised TKA have similar patient outcomes and ROM at a mean follow-up of 3 years compared to PS TKA. Highly congruent inserts could be used without compromising results in TKA at short term. Level of evidence Level IV, retrospective case control study.
Collapse
Affiliation(s)
- Jobe Shatrov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Sydney Orthopaedic Research Institute, Chatswood, Sydney, Australia.,University of Notre Dame Australia, Sydney, Australia.,Hornsby and Ku-Ring Hospital, Sydney, Australia
| | - Elliot Sappey-Marinier
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France. .,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France.
| | - Moussa Kafelov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Stanislas Gunst
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Cécile Batailler
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France
| | - Elvire Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| | - Sébastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France
| |
Collapse
|