1
|
Zhu Y, Guo X, Ma X, Liu K, Han Y, Wu Y, Li X. Rare earth upconversion luminescent composite based on energy transfer for specific and sensitive detection of cysteine. Analyst 2023; 148:1016-1023. [PMID: 36723185 DOI: 10.1039/d2an01994a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Abnormal levels of thiols in cysteine (Cys) have been shown to be associated with growth retardation, skin lesions, and neurotoxicity in humans. Herein, we designed and synthesized a rare earth upconversion luminescent (UCL) nanocomposite probe UCNP-PEG-NOF1 for the UCL detection of Cys using NOF1 developed by our group as a Cys probe. The core structure of rare earth nanoparticles can absorb light at 980 nm and convert it into visible light. The detection principle of Cys was based on the change in absorption peak before and after the reaction between NOF1 and Cys, as well as the change in UCL intensity. The rare earth nanocomposite in the probe could be excited by near-infrared light and had low background fluorescence and strong penetration ability; thus, the probe was successfully employed to specifically and sensitively detect Cys with a low background signal. Overall, the developed UCNP-PEG-NOF1 probe had good selectivity and high sensitivity for Cys; its detection limit was as low as 83 nM.
Collapse
Affiliation(s)
- Yulian Zhu
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| | - Xiaomei Guo
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| | - Xiao Ma
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| | - Kai Liu
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| | - Yuting Han
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| | - Yongquan Wu
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| | - Xun Li
- School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou 341000, P. R. China.
| |
Collapse
|
2
|
Highly selective and sensitive electrochemical determination of cysteine based on complexation with gold nanoparticle–modified copper-based metal organic frameworks. Anal Bioanal Chem 2022; 414:2343-2353. [DOI: 10.1007/s00216-021-03852-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 11/14/2021] [Accepted: 12/14/2021] [Indexed: 02/06/2023]
|
3
|
Hussain MM, Asiri AM, Uddin J, Rahman MM. Development of L-cysteine sensor based on thallium oxide coupled multi-walled carbon nanotube nanocomposites with electrochemical approach. Chem Asian J 2021; 17:e202101117. [PMID: 34904384 DOI: 10.1002/asia.202101117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 11/16/2021] [Indexed: 11/07/2022]
Abstract
Here, Nanocomposites of thallium oxide doped multi-walled carbon nanotube (Tl2O.MWCNT NCs) were prepared by utilizing the wet-chemical method (WCM) in an alkaline phase at low temperature. Different optical procedures (FTIR: Fourier Transform Infra-Red Spectroscopy, XRD: Powder X-ray diffraction, FESEM: Field-Emission Scanning Electron Microscopy, XEDS: X-ray Electron Dispersive Spectroscopy, TEM: Tunneling Electron Microscopy, and XPS: X-ray photoelectron spectroscopy) were used to fully characterize (Optical, structural, crystalline, morphological, and elemental etc.) of the prepared Tl2O.MWCNT NCs. Modification of the thin-layer with NCs onto glassy carbon electrode (GCE) is prepared and applied for the enzyme-free detection of selective and sensitive L-cysteine by electrochemical approach. Using a reliable current-voltage approach, analytical sensing indexes such as sensitivity, LDR, LOD, LOQ, durability, and interference were assessed by fabricated sensor probe (GCE/Tl2O.MWCNT NCs/CPM) in selective detection of L-cysteine in a room condition, whereas nafion was used as conducting polymer matrix (CPM) during the fabrication of GCE with NCs. L-cysteine calibration plot was found to be linear over an extensive range of concentration. The calibration curve was used to calculate the sensing parameters such as sensitivity (316.46 pAμM-1cm-2), LOD down to (~18.90 ± 1.89 pM), and LOQ (63.0 pM) of the prepared sensor. The use of a simple WCM to validate the Tl2O.MWCNT NCs is a good approach for developing a NCs-based sensor for enzyme-free biomolecule identification and detection in the biomedical and health care fields in a broad scale. This proposed sensor (GCE/Tl2O.MWCNT NCs/CPM) is used to detect selective L-cysteine in real biological samples such as human, mouse, and rabbit serum and found acceptable and satisfactory results.
Collapse
Affiliation(s)
| | | | - Jamal Uddin
- Coppin State University, Natural Sciences, UNITED STATES
| | | |
Collapse
|
4
|
Moulaee K, Neri G. Electrochemical Amino Acid Sensing: A Review on Challenges and Achievements. BIOSENSORS 2021; 11:502. [PMID: 34940259 PMCID: PMC8699811 DOI: 10.3390/bios11120502] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/18/2021] [Accepted: 11/25/2021] [Indexed: 05/05/2023]
Abstract
The rapid growth of research in electrochemistry in the last decade has resulted in a significant advancement in exploiting electrochemical strategies for assessing biological substances. Among these, amino acids are of utmost interest due to their key role in human health. Indeed, an unbalanced amino acid level is the origin of several metabolic and genetic diseases, which has led to a great need for effective and reliable evaluation methods. This review is an effort to summarize and present both challenges and achievements in electrochemical amino acid sensing from the last decade (from 2010 onwards) to show where limitations and advantages stem from. In this review, we place special emphasis on five well-known electroactive amino acids, namely cysteine, tyrosine, tryptophan, methionine and histidine. The recent research and achievements in this area and significant performance metrics of the proposed electrochemical sensors, including the limit of detection, sensitivity, stability, linear dynamic range(s) and applicability in real sample analysis, are summarized and presented in separate sections. More than 400 recent scientific studies were included in this review to portray a rich set of ideas and exemplify the capabilities of the electrochemical strategies to detect these essential biomolecules at trace and even ultra-trace levels. Finally, we discuss, in the last section, the remaining issues and the opportunities to push the boundaries of our knowledge in amino acid electrochemistry even further.
Collapse
Affiliation(s)
- Kaveh Moulaee
- Department of Engineering, University of Messina, C.Da Di Dio, I-98166 Messina, Italy;
- Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran 16846-13114, Iran
| | - Giovanni Neri
- Department of Engineering, University of Messina, C.Da Di Dio, I-98166 Messina, Italy;
| |
Collapse
|
5
|
Jankhunthod S, Moonla C, Watwiangkham A, Suthirakun S, Siritanon T, Wannapaiboon S, Ngamchuea K. Understanding electrochemical and structural properties of copper hexacyanoferrate: Application in hydrogen peroxide analysis. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.139147] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
A sensitive signal-on electrochemiluminescence sensor based on a nanocomposite of polypyrrole-Gd2O3 for the determination of L-cysteine in biological fluids. Mikrochim Acta 2020; 187:398. [DOI: 10.1007/s00604-020-04372-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/02/2020] [Indexed: 11/27/2022]
|
7
|
Direct electroiodimetric sensing of reducing biomolecules using a modified multiwall carbon nanotube/ionic liquid paste electrode by tetra-n-octylammonium triiodide. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.09.125] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
8
|
Biosensing based on pencil graphite electrodes. Talanta 2018; 190:235-247. [DOI: 10.1016/j.talanta.2018.07.086] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 07/24/2018] [Accepted: 07/27/2018] [Indexed: 12/20/2022]
|
9
|
Nacef M, Chelaghmia ML, Affoune AM, Pontié M. Electrochemical Investigation of Glucose on a Highly Sensitive Nickel-Copper Modified Pencil Graphite Electrode. ELECTROANAL 2018. [DOI: 10.1002/elan.201800622] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Mouna Nacef
- Laboratoire d'Analyses Industrielles et Génie des Matériaux; Université 8 Mai 1945 Guelma BP 401; Guelma 24000 Algérie
| | - Mohamed Lyamine Chelaghmia
- Laboratoire d'Analyses Industrielles et Génie des Matériaux; Université 8 Mai 1945 Guelma BP 401; Guelma 24000 Algérie
| | - Abed Mohamed Affoune
- Laboratoire d'Analyses Industrielles et Génie des Matériaux; Université 8 Mai 1945 Guelma BP 401; Guelma 24000 Algérie
| | - Maxime Pontié
- Université de Bretagne Loire, Univ. d'Angers; Laboratoire GEIHP EA 3142; Institut de Biologie en Santé, PBH-IRIS; CHU, Université d'Angers; 4 Rue Larrey, 49933 Angers Cedex 9 Angers France
| |
Collapse
|
10
|
Brainina K, Stozhko N, Bukharinova M, Vikulova E. Nanomaterials: Electrochemical Properties and Application in Sensors. PHYSICAL SCIENCES REVIEWS 2018. [DOI: 10.1515/psr-2018-8050] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
The unique properties of nanoparticles make them an extremely valuable modifying material, being used in electrochemical sensors. The features of nanoparticles affect the kinetics and thermodynamics of electrode processes of both nanoparticles and redox reactions occurring on their surface. The paper describes theoretical background and experimental studies of these processes. During the transition from macro- to micro- and nanostructures, the analytical characteristics of sensors modify. These features of metal nanoparticles are related to their size and energy effects, which affects the analytical characteristics of developed sensors. Modification of the macroelectrode with nanoparticles and other nanomaterials reduces the detection limit and improves the degree of sensitivity and selectivity of measurements. The use of nanoparticles as transducers, catalytic constituents, parts of electrochemical sensors for antioxidant detection, adsorbents, analyte transporters, and labels in electrochemical immunosensors and signal-generating elements is described.
Collapse
|
11
|
Yan F, Sun X, Zu F, Bai Z, Jiang Y, Fan K, Wang J. Fluorescent probes for detecting cysteine. Methods Appl Fluoresc 2018; 6:042001. [PMID: 30039804 DOI: 10.1088/2050-6120/aad580] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Cysteine plays a crucial role in physiological processes. Therefore, it is necessary to develop a method for detecting cysteine. Fluorimetry has the advantages of convenient detection, short response time, high sensitivity and good selectivity. In this review, fluorescent probes that detect cysteine over the past three years are summarized based on structural features of fluorophores such as coumarin, BODIPY, rhodamine, fluorescein, CDs, QDs, etc and reaction groups including acrylate, aldehyde, halogen, 7-nitrobenzofurazan, etc. Then, effects of different combinations between fluorophores and response groups on probe properties and detection performances are discussed.
Collapse
|
12
|
Selective electrochemical sensor based on the electropolymerized p-coumaric acid for the direct determination of l-cysteine. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.03.102] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
13
|
Comparative study of carbon fiber structure on the electrocatalytic performance of ZIF-67. Anal Chim Acta 2017; 984:96-106. [DOI: 10.1016/j.aca.2017.07.020] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 07/06/2017] [Accepted: 07/11/2017] [Indexed: 11/23/2022]
|
14
|
David IG, Popa DE, Buleandra M. Pencil Graphite Electrodes: A Versatile Tool in Electroanalysis. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2017; 2017:1905968. [PMID: 28255500 PMCID: PMC5307002 DOI: 10.1155/2017/1905968] [Citation(s) in RCA: 87] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Revised: 12/19/2016] [Accepted: 01/04/2017] [Indexed: 05/05/2023]
Abstract
Due to their electrochemical and economical characteristics, pencil graphite electrodes (PGEs) gained in recent years a large applicability to the analysis of various types of inorganic and organic compounds from very different matrices. The electrode material of this type of working electrodes is constituted by the well-known and easy commercially available graphite pencil leads. Thus, PGEs are cheap and user-friendly and can be employed as disposable electrodes avoiding the time-consuming step of solid electrodes surface cleaning between measurements. When compared to other working electrodes PGEs present lower background currents, higher sensitivity, good reproducibility, and an adjustable electroactive surface area, permitting the analysis of low concentrations and small sample volumes without any deposition/preconcentration step. Therefore, this paper presents a detailed overview of the PGEs characteristics, designs and applications of bare, and electrochemically pretreated and chemically modified PGEs along with the corresponding performance characteristics like linear range and detection limit. Techniques used for bare or modified PGEs surface characterization are also reviewed.
Collapse
Affiliation(s)
- Iulia Gabriela David
- Department of Analytical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90–92, District 5, 050663 Bucharest, Romania
| | - Dana-Elena Popa
- Department of Analytical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90–92, District 5, 050663 Bucharest, Romania
| | - Mihaela Buleandra
- Department of Analytical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90–92, District 5, 050663 Bucharest, Romania
| |
Collapse
|
15
|
Sundaram S, Kadir MRA. A New Highly Conducting Carbon Black (CL-08) Modified Electrode Functionalized with Syringic Acid for Sensitive and Selective L-Cysteine Electrocatalysis at Low Potential. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2016.12.093] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
16
|
Amperometric L-cysteine sensor based on a carbon paste electrode modified with Y2O3 nanoparticles supported on nitrogen-doped reduced graphene oxide. Mikrochim Acta 2016. [DOI: 10.1007/s00604-015-1737-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
17
|
An unusual electrochemical oxidation of phenothiazine dye to phenothiazine-bi-1,4-quinone derivative (a donor-acceptor type molecular hybrid) on MWCNT surface and its cysteine electrocatalytic oxidation function. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2015.11.032] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
18
|
Akanda MR, Sohail M, Aziz MA, Kawde AN. Recent Advances in Nanomaterial-Modified Pencil Graphite Electrodes for Electroanalysis. ELECTROANAL 2015. [DOI: 10.1002/elan.201500374] [Citation(s) in RCA: 90] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
19
|
Galán-Mascarós JR. Water Oxidation at Electrodes Modified with Earth-Abundant Transition-Metal Catalysts. ChemElectroChem 2014. [DOI: 10.1002/celc.201402268] [Citation(s) in RCA: 199] [Impact Index Per Article: 18.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
20
|
Ghaffarinejad A, Hashemi F, Nodehi Z, Salahandish R. A simple method for determination of d-penicillamine on the carbon paste electrode using cupric ions. Bioelectrochemistry 2014; 99:53-6. [DOI: 10.1016/j.bioelechem.2014.06.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2014] [Revised: 05/26/2014] [Accepted: 06/17/2014] [Indexed: 10/25/2022]
|
21
|
Improved sensing of dopamine and ascorbic acid using a glassy carbon electrode modified with electrochemically synthesized nickel-cobalt hexacyanoferrate microparticles deposited on graphene. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1371-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
22
|
Mangiferin DNA biosensor using double-stranded DNA modified pencil graphite electrode based on guanine and adenine signals. J Electroanal Chem (Lausanne) 2014. [DOI: 10.1016/j.jelechem.2014.03.039] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
23
|
Wang X, Wen Y, Lu L, Xu J, Zhang L, Yao Y, He H. A NovelL-Cysteine Electrochemical Sensor Using Sulfonated Graphene-poly(3,4-Ethylenedioxythiophene) Composite Film Decorated with Gold Nanoparticles. ELECTROANAL 2014. [DOI: 10.1002/elan.201300551] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
The effect of thiourea, l(−) cysteine and glycine additives on the mechanisms and kinetics of copper electrodeposition. J APPL ELECTROCHEM 2013. [DOI: 10.1007/s10800-013-0596-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
25
|
Majidi MR, Naseri A, Panahian S, Baj RFB. Electrocatalytic Oxidation and Determination of Nitrite at Multi-walled Carbon Nanotubes Modified Carbon Ceramic Electrode. J CHIN CHEM SOC-TAIP 2012. [DOI: 10.1002/jccs.201200365] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
26
|
Haghighi B, Nazari L, Sajjadi SM. Fabrication and Application of a Sensitive and Highly Stable Copper Hexacyanoferrate Modified Carbon Ionic Liquid Paste Electrode for Hydrogen Peroxide and Glucose Detection. ELECTROANAL 2012. [DOI: 10.1002/elan.201200277] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
27
|
Electrocatalytic oxidation of NADH using a pencil graphite electrode modified with quercetin. Colloids Surf B Biointerfaces 2012; 102:816-21. [PMID: 23107961 DOI: 10.1016/j.colsurfb.2012.09.030] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2012] [Revised: 09/12/2012] [Accepted: 09/17/2012] [Indexed: 11/23/2022]
Abstract
In the present study, the electrocatalytic oxidation of reduced β nicotinamide adenine dinucleotide (NADH) was investigated using a pencil graphite electrode modified with quercetin (PGE/QH(2)). The PGE/QH(2) was prepared through two steps: (i) the pre-treatment of PGE at 1.40 V vs. Ag|AgCl|KCl((sat.)) in pH 7.0 phosphate buffer containing 0.1 M KCl for 60s and (ii) adsorption of QH(2) on the PGE via immersion of PGE into a 1.0mM QH(2) solution (in ethanol) for 60s. Cyclic voltammetric studies show that the peak potential of NADH oxidation shifts from +500 mV at bare PGE to +300 mV at PGE/QH(2). The electrocatalytic currents obtained from amperometric measurements at +300 mV vs. Ag|AgCl|KCl((sat.)) and in phosphate buffer solution at pH 7.0 containing 0.1M KCl were linearly related to the concentration of NADH. Linear calibration plots are obtained in the concentration range from 0.5 μM to 100 μM. The limit of detection was found to be 0.15 μM.
Collapse
|
28
|
Pandey PC, Pandey AK, Chauhan DS. Nanocomposite of Prussian blue based sensor for l-cysteine: Synergetic effect of nanostructured gold and palladium on electrocatalysis. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.03.179] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
29
|
de Carvalho Castro e Silva C, Breitkreitz MC, Santhiago M, Corrêa CC, Kubota LT. Construction of a new functional platform by grafting poly(4-vinylpyridine) in multi-walled carbon nanotubes for complexing copper ions aiming the amperometric detection of l-cysteine. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.03.114] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
30
|
Liu Z, Zhang H, Hou S, Ma H. Highly sensitive and selective electrochemical detection of L-cysteine using nanoporous gold. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0801-x] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
31
|
Determination of L-cysteine base on the reversion of fluorescence quenching of calcein by copper(II) ion. Mikrochim Acta 2012. [DOI: 10.1007/s00604-011-0759-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
32
|
Wang Y, Luo L, Ding Y, Zhang X, Xu Y, Liu X. Perovskite nanoparticles LaNi0.5Ti0.5O3 modified carbon paste electrode as a sensor for electrooxidation and detection of amino acids. J Electroanal Chem (Lausanne) 2012. [DOI: 10.1016/j.jelechem.2011.12.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
33
|
Dilgin Y, Kızılkaya B, Ertek B, Eren N, Dilgin DG. Amperometric determination of sulfide based on its electrocatalytic oxidation at a pencil graphite electrode modified with quercetin. Talanta 2012; 89:490-5. [DOI: 10.1016/j.talanta.2011.12.074] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2011] [Revised: 12/26/2011] [Accepted: 12/28/2011] [Indexed: 10/14/2022]
|
34
|
Application of nanocrystalline graphite-like pyrolytic carbon film electrode for determination of thiols. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.10.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
35
|
Nezamzadeh-Ejhieh A, Hashemi HS. Voltammetric determination of cysteine using carbon paste electrode modified with Co(II)-Y zeolite. Talanta 2011; 88:201-8. [PMID: 22265488 DOI: 10.1016/j.talanta.2011.10.032] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2011] [Revised: 09/10/2011] [Accepted: 10/06/2011] [Indexed: 10/15/2022]
Abstract
A novel zeolite modified electrode for use in voltammetric determination of l-cysteine (CySH) was described. The electrode comprises a Co(II)-exchanged zeolite Y as modifier in carbon paste matrix. First, the electrochemical behavior of Co(II) in modified carbon paste electrode was studied. The results demonstrated that diffusion can control the redox process of cobalt cations at the surface of the modified electrode. Then, the behavior of the electrode in the presence of CySH was studied by using cyclic voltammetry and a novel behavior was observed. In high concentration of CySH (above 10 mmol L(-1)), one pair of semi-reversible electrochemical extra peak was observed which was assigned to the processes of oxidation-reduction of CySH at the unmodified and modified electrode. Acidic conditions with respect to the neutral one cause an increase in the electrode response. The modified electrode showed a suitable linear calibration graph in the concentration range of 1.0×10(-9)-1.0×10(-3)mol L(-1) cysteine with a detection limit of 2.37×10(-10)mol L(-1). The influence of potential interfering substances on the peak current was studied and the results showed that the method was highly selective for determination of CySH. Thus, the proposed electrode was used for the determination of CySH in real samples including human blood serum, urine, N-acetylcysteine tablet and powdered poultry feed and the satisfactory results were obtained. Typical features of the sensor can be summarized as: low cost, simple preparation, fast response, good stability and selectivity, wide linear range, low detection limit and high reproducibility.
Collapse
Affiliation(s)
- Alireza Nezamzadeh-Ejhieh
- Department of Chemistry, Shahreza Branch, Islamic Azad University, P.O. Box 311-86145, Shahreza, Isfahan, Iran.
| | | |
Collapse
|
36
|
Preparation of yttrium hexacyanoferrate/carbon nanotube/Nafion nanocomposite film-modified electrode: Application to the electrocatalytic oxidation of l-cysteine. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2010.12.090] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|